Fujitsu Printer FTP 633MCL400 User Manual

BATTERY DRIVE, MICRO LINE THERMAL PRINTER  
3” TYPE MECHANISM AND INTERFACE BOARD  
FTP-633MCL400/FTP-623DCL002  
OVERVIEW  
This battery driven, micro line thermal printer offers high speed  
printing for 3-inch wide paper (70 mm). It is suitable for portable  
equipment that requires compact, lightweight components.  
In addition to the interface board, a driving LSI (MCU + Gate  
Array) is also available.  
HIGHLIGHTS  
• Driven by batteries (direct connect between thermal  
head and batteries)  
FTP-633MCL400  
It can be driven by a broad range of voltages (4.2 to 8.5 V) of  
NiCd or Nickel-Hydrogen by using Fujitsu Components'  
unique head drive control system. The battery pack can be  
connected directly to the print head without a voltage  
regulator. Also, a lithium-ion battery can be applied.  
• High speed printing  
It can print at approximately 24 character lines/s (460  
dotlines/s = 60 mm/s).  
• Compact and lightweight  
It has a light weight of approximately 84 g.  
FTP-623CU001, FTP-633GA101  
• Low power consumption  
The peak current for head driving is approximately 3.0 A.  
• Selectable paper paths  
Front, rear and top paper insertion paths can be used.  
• Paper auto loading function  
Paper feeding is enabled by operating the head up lever.  
• Variety of suitable paper  
This model is capable of printing on a variety of papers,  
including 1-ply roll paper, 2-ply paper (TCC and roll), labels,  
and long-life paper.  
FTP-623DCL002  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
(Continued)  
Item  
Specifications  
4.2 to 8.5 VDC (4 or 5 Ni-Cd or Ni-MH batteries, equivalent to 2 Li-ion)  
Approximately 3.0 A (peak value, 7.2 V, 100% printing ratio)  
For print head  
Operating  
voltage  
4.2 to 8.5 VDC (4 or 5 Ni-Cd or Ni-MH batteries, equivalent to 2 Li-ion)  
Average 0.7 A or less  
For motor  
For logic  
5 VDC ± 5%, 0.15 A  
Weight  
Mechanism: approximately 84 g. Interface board: approximately 60 g  
85 (W) × 49 (D) × 20 (H) mm (excluding knob, lever, and flexible PC board)  
108 (W) × 91 (D) × 18 (H) mm  
Printer mechanism Dimensions  
Interface board  
Dimensions  
Pulse durability : 1 × 108 pulse/dot (using Fujitsu Takamisawa's standard  
driving method)  
Thermal head life  
Wear resistance: 50 km (at 25% printing ratio)  
Operating temperature  
Operating humidity  
Storage temperature  
Storage humidity  
Head temperature  
Paper out/Mark detect  
Voltage  
+5 to +40°C*3  
Environmental  
conditions  
20 to 85% RH (no condensation)  
–20 to +60°C (excluding paper)  
5 to 95% RH (no condensation)  
By thermistor  
Detection  
By photointerrupter (command set)  
By micro controller  
Head-up  
By microswitch  
+0  
Paper width  
70 mm  
–1  
Recommended thermal sensitive paper  
1 ply (roll) : FTP-030PG021  
2 ply (TCC) : FTP-030P8021  
Long life (roll) : FTP-030PR202  
*1: Character composition for single density reduced mode is the same as for single density standard mode.  
*2: The data to be printed is automatically read out by the printer driver equipment memory (host system frame  
memory). The communication is parameter transfer.  
*3: Temperature range for guaranteed printing density. It can be operated in the range of 0 to +40°C.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
DIMENSIONS  
Printer mechanism  
FTP-633MCL400  
74.5  
3.9  
6.1  
12.5  
40  
20  
(3)  
(1)  
3
5
Paper center  
85  
2
2.3  
1.7  
12 (14)  
(2)  
Paper out  
angle  
(1): Head down  
(2): Paper feed  
(3): Head up lock  
30  
(Photo interrupter)  
Unit: mm  
Photo interrupter  
70.2 (Paper insertion)  
Front and top insertion type  
FTP-633MCL402  
74.5  
12.5  
3.9  
6.1  
40  
20  
(3)  
(1)  
3
5
1.7  
3.1  
Paper center  
85  
2
12 (14)  
(2)  
Photo  
interrupter  
Paper out  
angle  
(Photo  
interrupter)  
(1): Head down  
(2): Paper feed  
(3): Head up lock  
30  
(Photo interrupter)  
Unit: mm  
Rear insertion type  
Photo interrupter  
70.2 (Paper insertion)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
Interface board  
108.0  
102.9  
69.8  
5.1  
CN5  
ø3.6  
CN4  
CN8  
CN7  
CN6  
CN2  
CN1  
5.1  
16.5  
73.7  
102.9  
Height of devices side  
Height of solder side  
Unit: mm  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
INTERFACE  
1. Centronics standard  
(1) Connector  
Connector part number  
: FCN-215Q030-G/0 (Fujitsu Components) or equivalent  
Mating connector part number : FCN-217Q030-G/0 (Fujitsu Components) or equivalent  
FCN-214Q030-G/0 (Fujitsu Components) or equivalent  
FCN-215Q030-G/0 (Fujitsu Components) or equivalent  
(2) Connector pin assignment  
No.  
1
Signal  
PRSTB  
I/O  
Contents  
Data strobe  
No.  
2
Signal  
I/O  
I
Contents  
I
I
PRSTB-RET  
PRDT0-RET  
PRDT1-RET  
PRDT2-RET  
PRDT3-RET  
PRDT4-RET  
PRDT5-RET  
PRDT6-RET  
PRDT7-RET  
ACKNLG-RET  
BUSY-RET  
INPRM-RET  
INPRM  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Connected to logic GND  
Reset  
3
PRDT0  
PRDT1  
PRDT2  
PRDT3  
PRDT4  
PRDT5  
PRDT6  
PRDT7  
ACKNLG  
BUSY  
Data 0  
4
5
I
Data 1  
6
7
I
Data 2  
8
9
I
Data 3  
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
11  
13  
15  
17  
19  
21  
23  
25  
27  
I
Data 4  
I
Data 5  
I
Data 6  
I
Data 7  
O
O
O
I
Data input acknowledge  
Busy  
RINF2  
SLCTIN  
RINF1  
ATF  
Printer status  
Printer select  
Printer status  
Paper feed request  
O
I
RINF3  
O
Printer status  
29  
GND  
Logic GND  
Notes:  
• Symbol ” means a negative logic signal.  
• “–RET” signal is a return signal of the twisted pair cable.  
• “I” or “O” means a signal direction from the interface board side.  
(3) Connector pin number  
(4) Data input signal timing  
FCN-215Q030-G/0 (Fujitsu Components) or  
PRDT0~7  
equivalent  
3
t1  
t3  
PRSTB  
BUSY  
1
29  
t2  
t4  
ACKNLG  
t5  
Data set time  
:t10.5 µsec  
:t20.5 µsec  
:t30.5 µsec  
:t40.5 µsec  
:t5=1.0~1.5 µsec  
PRSTB pulse width  
Data hold time  
PRSTB to BUSY= “H”  
ACKNLG pulse time  
2
30  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
2. Bus interface  
(1) Connector  
Connector part number  
: FCN-215Q040-G/0 (Fujitsu Components) or equivalent  
Mating connector part number : FCN-217J040-G/0 (Fujitsu Components) or equivalent  
: FCN-214J040-G/0 (Fujitsu Components) or equivalent  
: FCN-215J040-G/0 (Fujitsu Components) or equivalent  
(2) Connector pin assignment  
No.  
1
Signal  
ALE  
I/O  
O
O
I
Contents  
Address latch  
No.  
2
Signal  
BRD  
I/O  
O
Contents  
Data read  
3
BWR  
Data write  
4
READY  
HRQ  
Data access ready  
User hold request input  
System clock  
5
HACK  
MCRC  
PCPAK1  
PCPSD1  
RST  
Hold acknowledge  
Power-down (not used)  
6
7
8
CLK  
9
Common RAM reading completion 10 ATF  
I
Automatic paper loading  
Printer operating  
Ground  
11  
13  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
35  
37  
39  
Notes:  
Common RAM reading request  
Hard reset  
12 PRON  
14 GND  
16 DB01  
18 DB03  
20 DB05  
22 DB07  
24 AB09  
26 AB11  
28 AB13  
30 AB15  
32 AB17  
34 AB19  
36 AB21  
38 AB23  
40 INPRM  
O
I
DB00  
DB02  
DB04  
DB06  
AB08  
AB10  
AB12  
AB14  
AB16  
AB18  
AB20  
AB22  
RAM2  
I/O External address/Data bus 0  
I/O External address/Data bus 2  
I/O External address/Data bus 4  
I/O External address/Data bus 6  
I/O External address/Data bus 1  
I/O External address/Data bus 3  
I/O External address/Data bus 5  
I/O External address/Data bus 7  
O
O
O
O
O
O
O
O
O
External address bus 08  
External address bus 10  
External address bus 12  
External address bus 14  
External address bus 16  
External address bus 18  
External address bus 20  
External address bus 22  
Common RAM access  
O
O
O
O
O
O
O
O
I
External address bus 09  
External address bus 11  
External address bus 13  
External address bus 15  
External address bus 17  
External address bus 19  
External address bus 21  
External address bus 23  
Reset  
• Symbol ” means a negative logic signal.  
• “I” or “O” means a signal direction from the interface bpard side.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
CONNECTOR PIN ASSIGNMENT  
1. Connector for logic power supply (CN1)  
Part number  
: B4B-XH-A-WHITE (J.S.T) or equivalent P.C.B side  
Mating connector part number : XHP-4 (J.S.T) or equivalent Cable side  
No.  
1
Signal  
I/O  
Contents  
No.  
2
Signal  
GND  
I/O  
Contents  
VCC  
Power supply for logic (+5V)  
Logic ground  
2. Connector for thermal head and motor power supply (CN2)  
Part number  
: B6B-XH-A-WHITE (J.S.T) or equivalent P.C.B side  
Mating connector part number : XHP-6 (J.S.T) or equivalent Cable side  
No.  
1
Signal  
BAT  
I/O  
Contents  
No.  
2
Signal  
BAT  
I/O  
Contents  
Power supply for head/motor  
Head/motor ground  
Power supply for head/motor  
Power supply for head/motor  
Head/motor ground  
3
BAT  
4
GND  
GND  
5
GND  
6
Head/motor ground  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
3. Connector for thermal head drive (CN7)  
Part number  
: 52030-2610 (Molex) or equivalent P.C.B side  
No.  
Signal  
BAT  
I/O  
O
Contents  
Power for head  
No.  
2
Signal  
BAT  
I/O  
O
Contents  
Power for head  
1
3
GND  
Head ground  
4
GND  
LAT  
Head ground  
5
HD2  
Print data output  
6
Printing data latch  
Printing transmitting clock  
Printing enable  
7
HDV  
O
Power for logic  
8
HCLK  
O
9
ENB8 *1, 2  
ENB6  
VREF  
O
Printing enable  
10 ENB7 *1, 2  
12 ENB5  
14 TMP  
O
11  
13  
15  
17  
19  
21  
23  
25  
Notes:  
O
Printing enable  
Printing enable  
O
Power for thermistor  
Connected with No. 17  
Connected with No. 15  
Not used (pulled-up by resistor)  
Automatic paper loading  
Printing enable  
O
Temperature detection  
Power for logic  
3
*
O
16 HDV  
O
3
4
*
18  
*
O
Head rank specify (not used)  
Printing enable  
4
*
20 ENB4  
22 ENB2  
24 GND  
26 BAT  
ENB3  
ENB1  
GND  
O
Printing enable  
O
Paper-out detection  
Power for head  
Printing enable  
*1: Mechanism selection signal and the printing enable signal for 3” mechanism.  
*2: Not used at the combination with 2” mechanism.  
*3: At the mechanism side, this pin number is for the printing data 2.  
Since this pin number is used for the printing data 1 at the inter face board, the No. 15 and No. 17 pins are  
connected.  
*4: This signal is used for the adjustment of printing duty depending upon the rank of thermal head resistor. Not  
used at this interface board.  
• Symbol ” means a negative logic signal.  
• “I” or “O” means a signal direction from the interface board side.  
4. Connector for abnormal head temperature detection (CN6)  
Part number  
: B3B-XH-A-WHITE (J.S.T) or equivalent P.C.B side  
Mating connector part number : XHP-3 (J.S.T) or equivalent Cable side  
No.  
1
Signal  
TMPER  
GND  
I/O  
O
Contents  
Abnormal head temperature detection  
Logic ground  
No.  
2
Signal  
N.C.  
I/O  
Contents  
Not connected  
3
Note: This signal detects abnormal head temperature.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
5. Connector for stepping motor drive (CN8)  
Part number  
: B10B-ZR (J.S.T) or equivalent P.C.B side  
Mating connector part number : ZHR-10 (J.S.T) Mechanism side  
No.  
1
Signal  
HUP  
I/O  
I
Contents  
Head up detection  
No.  
2
Signal  
I/O  
I
Contents  
Power for switch  
VCC  
3
PINCH  
SLED  
I
Paper auto loading detection  
Power for diode cathode  
4
SDV  
Power for photointerrupter  
Paper out detection  
5
O
O
6
PES  
7
MT/B0  
MT/A0  
Stepping motor coil excitation (B)  
8
MT/B0  
O
Stepping motor coil excitation (B)  
Stepping motor coil excitation (A)  
9
Stepping motor coil excitation (A) 10 MT/A0  
O
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
PRINTING COMMANDS (CENTRONICS STANDARD INTERFACE)  
Name  
Command  
Contents  
Carriage return  
LF, CR  
SO  
Prints buffer data and return the line.  
Sets the double width character.  
Double width print set  
Power-down mode set  
DC2, DC3  
Reduces the power consumption during standing  
by.  
Double width print reset  
ESC sequence entry  
DC4  
ESC  
Resets the double with character.  
Indicates the start of an escape sequence formed  
by this code plus subsequent commands.  
Line space set  
ESC A + n  
Sets the line space length in 2 × (0 to 255 dot  
lines).  
Paper feed set in normal direction  
Bit image print set  
ESC B + n  
Sets the paper feed in normal direction.  
(Feeding range: 2 × (0 to 255 dot lines))  
ESC K +n1+n2+n3  
Sets the bit image printing in single or double  
density mode.  
International character set  
Download character register  
ESC R+n  
Selects the international characters.  
ESC &+n1+n2+~  
Registers the download characters of 12 × 6 or 16  
× 8 dots.  
Printing quality set  
Printing density set  
ESC Q+n+SP*+~  
ESC Q+n+!+A  
Sets the printing quality conforming to used paper.  
Sets the printing density mode.  
(Single density standard, reduced or double  
density)  
Paper feed set in reverse direction  
Character grade set  
ESC j+n  
ESC x+n  
Sets the paper feed in reverse direction.  
(Feeding range: 2 × (1 to 255 dot lines))  
Sets the character grade in standard or high  
grade.  
Special character print set  
ESC ¥+n  
ESC 1+n  
Prints the special character.  
Start position set for bit-image printing  
Sets the print start position of bit-image printing in  
left end.  
Detecting function set  
Mark detection  
ESC 9+n  
ESC FF  
Sets the detecting function.  
Feeds the paper to the marking position.  
Sets the line feed length after mark detection.  
Line feed length set after mark detection ESC w+n  
Automatic paper loading length set  
Automatic printing speed set  
Printer initialization  
ESC EM+n  
ESC s+n  
ESC @  
Sets paper feeding length for automatic paper  
loading.  
Sets the function mode in the automatic printing  
speed set.  
Initializes the printer MPU.  
Notes:  
*: “SP” means the space code (20H).  
Bus interface uses different commands.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FTP-633MCL400/FTP-623DCL002  
OPTIONS  
1. Cable  
Name  
For Centronics  
For Bus I/F  
Part number  
Cable length  
500 mm  
500 mm  
300 mm  
300 mm  
300 mm  
FTP-621Y202  
FTP-621Y203  
FTP-621Y401  
FTP-621Y601  
FTP-621Y204  
Interface cable  
Power supply cable (A): for logic motor  
Power supply cable (B): for thermal head  
Head abnormal temperature detection cable  
Europe  
Japan  
Fujitsu Components Europe B.V.  
Diamantlaan 25  
Fujitsu Component Limited  
Gotanda-Chuo Building  
2132 WV Hoofddorp  
Netherlands  
3-5, Higashigotanda 2-chome, Shinagawa-ku  
Tokyo 141, Japan  
Fujitsu Components  
International  
Headquarter  
Offices  
Tel: (31-23) 5560910  
Tel: (81-3) 5449-7010  
Fax: (81-3) 5449-2626  
Fax: (31-23) 5560950  
Asia Pacific  
North and South America  
Fujitsu Components America, Inc.  
250 E. Caribbean Drive  
Sunnyvale, CA 94089 U.S.A.  
Tel: (1-408) 745-4900  
Fujitsu Components Asia Ltd.  
102E Pasir Panjang Road  
#04-01 Citilink Warehouse Complex  
Singapore 118529  
Tel: (65) 375-8560  
Fax: (1-408) 745-4970  
Fax: (65) 273-3021  
© 2001 Fujitsu Components America, Inc. All company and product names are trademarks or registered  
trademarks of their respective owners. Rev. 09/2001  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EverFocus Security Camera ED230 User Manual
Extron electronic Power Supply PS 1210 User Manual
FEIN Power Tools Power Screwdriver SCT 5 40 User Manual
FireplaceXtrordinair Indoor Fireplace 1924E User Manual
Fluke Thermometer 53IIB User Manual
Frigidaire Refrigerator 242063800 User Manual
Frymaster Fryer Series SR52 User Manual
Gefen Flat Panel Television GTV ETH 2COAX User Manual
GE Microwave Oven CVM2072 User Manual
GE Monogram Switch ZBD3500ZZWW User Manual