Fujitsu Photo Scanner P3PC 1932 01EN User Manual

P3PC-1932-01EN  
fi-5530C2 Image Scanner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Thank you for purchasing the fi-5530C2 Duplex Color  
Scanner.  
Canadian DOC Regulations  
This document describes how to use fi-5530C2 and  
basic operation methods. Before you start using  
fi-5530C2 be sure to thoroughly read this manual to  
ensure correct use.  
This digital apparatus does not exceed the Class B  
limit for radio noise emissions from digital  
apparatus set out in the Radio interference  
Regulations of the Canadian Department of  
Communications.  
The "fi-5530C2 Operator’s Guide" stored on the Setup  
CD Rom provides useful and detailed information on  
Operations when you would like to use advanced fea-  
tures, Daily Care for maintenance of the scanner, and  
Replacing Consumables to maintain conditions for  
smooth scanning. Please also read the "fi-5530C2 Oper-  
ator’s Guide" for further information.  
This Class B digital apparatus complies with  
Canadian ICES-003.  
Le présent appareil numérique n'émet pas de  
parasites radioélectriques dépassant les limites  
applicables aux appareils numériques de la classe  
B et prescrites dans le Règlement sur le brouillage  
radioélectrique dictées par le Ministère des  
Communications du Canada.  
Cet appareil numérique de la classe B est  
conforme à la norme NMB-003 du Canada.  
Regulatory Information  
FCC declaration  
Bescheimigung des Herstellers /  
Importeurs  
This equipment has been tested and found to  
comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instruction manual, may cause harmful  
Für den fi-5530C2 wird folgendes bescheinigt:  
In Übereinsstimmung mit den Bestimmungen  
der EN45014(CE) funkentstört  
Maschinenlärminformationsverordnung  
3.GPSGV: Der höchste Schalldruckpegel beträgt  
70 dB (A) oder weniger, gemäß EN ISO 7779.  
interference to radio communications. However,  
there is no guarantee that interference will not  
occur in a particular installation. If this equipment  
does cause harmful interference to radio or  
television reception, which can be determined by  
turning the equipment off and on, the user is  
encouraged to try to correct the interference by  
one or more of the following measures:  
®
International ENERGY STAR Program  
As an ENERGY STAR®  
Partner, PFU LIMITED has  
determined that this product  
meets the ENERGY  
STAR® guidelines for  
energy efficiency.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
The International ENERGY  
and receiver.  
STAR® Office Equipment Program is an  
international program that promotes energy  
saving through the penetration of energy efficient  
computers and other office equipment. The  
program backs the development and  
dissemination of products with functions that  
effectively reduce energy consumption. It is an  
open system in which business proprietors can  
participate voluntarily. The targeted products are  
office equipment such as computers, monitors,  
printers, facsimiles, copiers, scanners, and  
multifunction devices. Their standards and logos  
are uniform among participating nations.  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
located.  
Consult your dealer or an experienced radio/TV  
technician.  
FCC warning: Changes or modifications not  
expressly approved by the party responsible for  
compliance could void the user’s authority to  
operate the equipment.  
The use of a shielded interface cable is  
required to comply with the Class B limits  
NOTICE  
of Part 15 of FCC rules.  
The length of the AC cable must be 3  
meters (10 feet) or less.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Do not put the substance contained in the lamp  
Note of Liability  
in your mouth as it has mercury.  
Do not breathe the chemical liquid contained in  
READ ALL OF THIS MANUAL CAREFULLY  
BEFORE USING THIS PRODUCT. IF THIS  
PRODUCT IS NOT USED CORRECTLY,  
UNEXPECTED INJURY MAY BE CAUSED TO  
USERS OR BYSTANDERS.  
the scanner lamps.  
Do not incinerate, crush, or shred the lamps or  
scanner parts.  
Also, keep this manual in a safe place so that it  
can be easily referred to during use of this  
product.  
Trademarks  
Microsoft and Window are registered trademarks  
of Microsoft Corporation in the United States and/  
or other countries.  
ISIS and QuickScan are trademarks or registered  
trademarks of EMC Corporation in the United  
States.  
While all efforts have been made to ensure the  
accuracy of all information in this manual, PFU  
assumes no liability to any party for any damage  
caused by errors or omissions or by statements of  
any kind in this manual, its updates or  
Adobe, the Adobe logo, and Acrobat are either  
registered trademarks of Adobe Systems  
Incorporated in the United States and/or other  
countries.  
Other product names are the trademarks or  
registered trademarks of the respective companies.  
supplements, whether such errors are omissions or  
statements resulting from negligence, accidents,  
or any other cause. PFU further assumes no  
liability arising from the application or use of any  
product or system described herein; nor any  
liability for incidental or consequential damages  
arising from the use of this manual. PFU disclaims  
all warranties regarding the information contained  
herein, whether expressed, implied, or statutory.  
How Trademarks Are Indicated In  
This Manual  
Use in High-safety Applications  
References to operating systems (OS) are  
indicated as follows:  
This product has been designed and manufactured  
on the assumption that it will be used in office,  
personal, domestic, regular industrial, and  
general-purpose applications. It has not been  
designed and manufactured for use in applications  
(simply called "high-safety applications" from  
here on) that directly involve danger to life and  
health when a high degree of safety is required,  
for example, in the control of nuclear reactions at  
nuclear power facilities, automatic flight control  
of aircraft, air traffic control, operation control in  
mass-transport systems, medical equipment for  
sustaining life, and missile firing control in  
weapons systems, and when provisionally the  
safety in question is not ensured. The user should  
use this product with adopting measures for  
ensuring safety in such high-safety applications.  
PFU LIMITED assumes no liability whatsoever  
for damages arising from use of this product by  
the user in high-safety applications, and for any  
claims or compensation for damages by the user  
or a third party.  
®
®
Microsoft Windows 2000  
Professional operating system.  
Windows 2000  
®
®
Microsoft Windows XP  
Professional operating system  
(32/64-bit),  
Windows XP  
®
®
Microsoft Windows XP Home  
Edition operating system.  
®
®
Microsoft Windows  
Windows  
Server 2003  
TM  
Server 2003 Standard Edition  
operating system (32/64-bit).  
®
®
TM  
Microsoft Windows Vista  
Windows Vista  
Home Basic operating system  
(32/64-bit),  
®
®
TM  
TM  
TM  
TM  
Microsoft Windows Vista  
Home Premium operating  
system (32/64-bit),  
®
®
Microsoft Windows Vista  
Business operating system  
(32/64-bit),  
About the use of mercury  
®
®
Microsoft Windows Vista  
Enterprise operating system  
(32/64-bit),  
Lamp(s) inside this product contain  
mercury and must be recycled or  
disposed of according to local, state, or  
federal laws.  
g
H
®
®
Microsoft Windows Vista  
Ultimate operating system  
(32/64-bit).  
To avoid unexpected injuries;  
fi-5530C2 Image Scanner Getting Started  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Where there is no distinction between the different  
versions of the above operating system, the  
general term "Windows " is used.  
This symbol alerts operators to helpful  
advice regarding operation.  
HINT  
®
®
Adobe Acrobat  
Adobe Acrobat  
All the descriptions in this manual assume the  
usage of Adobe Acrobat bundled with this  
product. However, Adobe Acrobat may be  
upgraded without notice. If the descriptions differ  
from the screens actually displayed, refer to the  
Acrobat’s “Help”.  
A TRIANGLE symbol indicates that special care  
and attention is required.  
The drawing inside the triangle shows the  
specific caution.  
A CIRCLE with a diagonal line inside shows  
action which users may not perform.  
The drawing inside or under the circle shows the  
specific action that is not allowed.  
Manufacturer  
Outline characters on a colored background  
show instructions users should follow.  
It may also include the drawing that shows the  
specific instruction.  
PFU LIMITED  
International Sales Dept., Imaging Business  
Division, Products Group  
Solid Square East Tower, 580 Horikawa-cho,  
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,  
Japan  
R
Warning Label  
Phone : (81-44) 540-4538  
The glass surface inside the ADF becomes hot  
during the operation. Be careful not to touch the  
glass surface inside the ADF.  
All Rights Reserved, Copyright© PFU LIMITED 2007  
About Maintenance  
The user must not perform repairs on this scanner.  
Contact the store where you purchased the scanner  
or an authorized FUJITSU Image Scanner service  
provider to make repairs to this product.  
Do NOT remove, stain or scratch the  
warning labels from the scanner.  
ATTENTION  
Warning Indications Used In This  
Manual  
Screen Examples In This Manual  
The screen examples in this manual are subject to  
change without notice in the interest of product  
improvement. If the actual displayed screen  
differs from the screen examples in this manual,  
operate by following the actual displayed screen  
while referring to the User's Manual of the scanner  
application you are using.  
This indication alerts operators to an  
operation that, if not strictly  
observed, may result in severe injury  
or death.  
This indication alerts operators to an  
operation that, if not strictly  
observed, may result in safety  
hazards to personnel or damage to  
equipment.  
The screenshots in this manual were captured  
from FUJITSU TWAIN32 scanner driver,  
ScandAll PRO Image Capturing Utility Software,  
FUJITSU ISIS scanner driver, QuickScan Pro™  
image capturing software and Adobe® Acrobat®.  
Symbols Used In This Manual  
This symbol alerts operators to particularly  
ATTENTION  
important information. Be sure to read this  
information.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Turn the scanner OFF if it is damaged.  
If the scanner is damaged for any reason,  
disconnect immediately the power plug in order  
to turn out the scanner. Contact the store  
where you purchased the scanner.  
Do not damage the AC cable.  
Do not put liquids inside the scanner.  
A damaged AC cable may cause fire or electric  
Do not insert or drop metal objects in to the  
scanner. Do not scan wet documents or  
documents with paper clips or staples. Do not  
splash or allow the scanner to get wet.  
shock. Do not place heavy objects on AC  
cables, or pull, bend, twist, heat, damage or  
modify AC cables.  
Do not use damaged AC cables or power  
plugs, or install any cables or power plugs to  
loose wall sockets.  
If foreign objects (water, small metal objects,  
liquids, etc.) get inside the scanner, immediately  
turn off the scanner and disconnect the power  
plug from the power outlet, then contact the store  
where you bought the scanner or the  
Maintenance Service Center. Pay particular  
attention to this warning in households where  
there are small children.  
Use only specified AC cables and  
connector cables  
Use only specified AC cables and connector  
cables. Failure to use the correct cables might  
cause electric shock and/or equipment failure.  
Please don’t use the AC cable provided with  
this scanner for other devices, since this might  
cause equipment failure and other troubles or  
an electric shock.  
Do not touch the inside of the scanner  
unless necessary.  
Do not take apart or modify the scanner. The  
inside of the scanner contains high-voltage  
components. Touching these components might  
cause fire or electric shock.  
Use this scanner only at the indicated  
power voltage. Do not connect to multiple-  
power strips.  
Do not use the scanner if there is a strange  
odor.  
Use this scanner only at the indicated power  
voltage and current. Improper power voltage  
and current might cause fire or electric shock.  
Do not connect to multiple-power strips.  
If you detect excessive heat coming from the  
device or detect other problems such as smoke,  
strange smells or noises, disconnect immediately  
the power plug in order to turn out the scanner.  
Make sure that any smoke coming from it has  
stopped, before contacting the store where you  
bought the scanner or an authorized FUJITSU  
scanner service provider.  
Do not touch the AC cable with wet hands.  
Do not touch the power plug with wet hands.  
Doing so might cause electric shock.  
Wipe any dust from the power plug.  
Wipe off any dust from metal parts on the  
power plug or metal fittings with a soft, dry  
cloth. Accumulated dust might cause fire or  
electric shock.  
Do not install the device in locations that  
has oil smoke, steam, humidity, and dust.  
Do not install the scanner in locations subject  
to oil smoke, steam, humidity, and dust. Doing  
so might cause a fire or electric shock.  
fi-5530C2 Image Scanner Getting Started  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Before moving the scanner, disconnect the  
power plug from the power outlet.  
Do not move the scanner with the power and  
interface cables connected as this might  
damage the cables, causing fire, electric shock  
or injuries. Before moving the scanner, be sure  
to disconnect the power plug from the power  
outlet, and all other data cables. Make sure that  
the floor is free of any obstruction.  
Do not install the scanner on unstable  
surfaces.  
Make sure that the scanner is installed on a  
flat, level surface and that none of its parts  
extend beyond the surface top, such as a desk  
or table. Do not install the scanner on  
unstable surfaces. Install the scanner on a level  
surface that is free of vibration to prevent it  
from falling.  
Install the scanner on a strong surface that will  
support the weight of the scanner and other  
devices.  
Protect the scanner from static electricity.  
Install the scanner away from strong magnetic  
fields and other sources of electronic noise.  
Also, protect the scanner from any static  
electricity as this might cause the scanner to  
malfunction.  
Do not block the ventilation ports.  
Do not use aerosol sprays near the  
scanner.  
Do not block the ventilation ports. Blocking the  
ventilation ports generates heat inside of  
scanner, which may results in fire or scanner  
failure.  
Do not use aerosol sprays to clean the scanner.  
Aerosol sprays cause dirt and dust to enter the  
scanner, resulting scanner failure and  
malfunction.  
Do not place heavy objects or stand on top  
of the scanner.  
Disconnect the power plug from the power  
outlet when the scanner is not used for a  
long period of time.  
Do not place heavy objects on the scanner or  
use the scanner's surface top to perform other  
work. Improper installation might cause injuries  
and equipment failure.  
When the scanner is not going to be used for a  
long period of time, be sure to disconnect the  
power plug from the power outlet for safety.  
Firmly insert the power plug.  
Firmly insert the power plug as far it can go into  
the power outlet.  
Do not install the scanner in the direct  
sunlight.  
Do not install the scanner under direct sunlight or  
near heating apparatus. Doing so might cause  
excessive heat to build up inside the scanner,  
which can cause scanner trouble or even fire.  
Install the scanner in a well-ventilated location.  
Avoid any contact when scanner is in use.  
Avoid touching any scanner mechanism during  
scanning since this may cause injuries.  
Do not use the scanner immediately after  
moving it from a cold place into a warm  
room.  
Do not use the device immediately after  
moving it from a cold place into a warm room.  
This may cause condensation, which might  
lead to scanning errors. Let the device dry  
about one or two hours before you use it.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter1 PREPARING THE SCANNER  
Removable Parts  
1.1 Checking the Contents of  
the Scanner Package  
The following shows the parts that can be removed from  
the scanner.  
When you unpack the scanner package, make sure that  
the package contains all the parts on the list included in  
the package.  
If any parts are missing or defective, contact your scan-  
ner dealer or an authorized FUJITSU scanner service  
provider. Handle the scanner and accessories with care.  
ADF paper chute  
Sheet guide  
Pad ASSY  
Pick roller  
1.2 Names of Parts  
This section describes the names of parts.  
Can be removed  
Front side  
(2) ADF paper chute  
(3) Side guide  
(1) Automatic document  
feeder (ADF)  
(4) ADF button  
(5) Operator panel  
(6) Stacker  
Rear side  
(10) DC inlet  
(9) USB Interface connector  
(11) EXT connector  
(8) SCSI Interface connector  
(7) SCSI ID switch  
fi-5530C2 Image Scanner Getting Started  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Indications on the Function  
1.3 Operator panel  
Number Display  
The operator panel is located on the right side of the  
scanner. The panel consists of a Function Number Dis-  
play, four buttons and a LED.  
The following shows the indications on the Function  
Number Display.  
Indication  
Meaning  
Function No.  
display  
Lights only one time upon turning on the  
scanner.  
8
P
0
1
Function  
Indicates that the scanner has been turned  
ON and is being initialized.  
Send to  
Indicates that initialization will soon be  
completed.  
Scan  
Power button  
Indicates that initialization has been com-  
pleted successfully.  
This status is called "Ready Status."  
LED  
.
Indicates that a temporary error (that users  
can solve) has occurred during the initial-  
ization or scanning of documents.  
[U] and an error number (1, 2, 6) are dis-  
played alternately.  
To return the scanner to the ready status  
([1]), press the [Scan] or [Send to] button  
while the error is indicated.  
U
Name  
Function  
Function Number  
Display  
Indicates the state of the scan-  
ner. The meaning of the num-  
bers and alphabets indicated  
are explained later in this sec-  
tion.  
Indicates that a device alarm (that users can  
not solve) has occurred during the initial-  
ization or scanning of documents.  
[E] and an alarm number (2 to 9, and, c, d,  
F) are indicated alternately.  
Buttons Function  
Changes the Function activated  
by the [Send to] button (*).  
E
Send to  
Launches the linked applica-  
tion software (*).  
Scan  
To return the scanner to the ready status  
([1]), press the [Scan] or [Send to] button.  
If this alarm occurs, turn the power off and  
then on again. If the alarm is indicated after  
turning on the power again, contact your  
servic engineer.  
Power button  
Turns the scanner ON and  
OFF.  
LED  
-
Lights when the scanner is  
turned ON.  
*) About the settings on the launcher, refer to FUJITSU  
TWAIN32 scanner driver help and "fi-5530C2 Oper-  
ator’s Guide" on the Setup CD-ROM.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter2  
INSTALLATION OF THE SCANNER  
2) Connect the AC adapter connector to the scan-  
2.1 Installing the Scanner  
ner’s DC inlet.  
1. Place the scanner at its installation site.  
For details on the scanner's dimensions and  
required installation space, refer to section 7.2  
"Installation Specifications" of "fi-5530C2 Oper-  
ator’s Guide" on the Setup CD-ROM.  
2. Attach the ADF paper chute.  
Hold the ADF paper chute and insert its tabs into  
the corresponding slots in the scanner as shown in  
the figure below.  
The Side guides of the ADF paper chute have to  
face up.  
3) Plug the AC cable into the outlet.  
ADF paper chute  
The Function Number Display and the LED  
HINT  
may flash for an instant when plugging the  
AC cable into the outlet.  
Tab  
2.2 Connecting the Scanner to  
Your Personal Computer  
Connect either with the USB interface cable or the SCSI  
interface cable.  
Side guide  
This scanner is provided with two inter-  
ATTENTION  
faces: Ultra SCSI and USB 2.0 /1.1. Con-  
nect only one of the USB or SCSI interface  
cable.  
3. Connect the AC adapter.  
Use only the AC adapter provided by the  
ATTENTION  
manufacturer.  
Connecting with the USB  
Interface Cable  
1. Connect the USB interface cable to the USB  
interface connector.  
1) Connect the AC cable to the AC adapter.  
fi-5530C2 Image Scanner Getting Started  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2. Connect the other end of the USB interface  
cable to your personal computer.  
1. Insert the SCSI interface cable into the inter-  
face connector of the scanner until both sides  
click.  
Be sure to use the USB cable which  
comes with this scanner as an acces-  
sory. Correct operation with commer-  
cially available cables is not guaranteed.  
ATTENTION  
When connecting to an USB hub, use  
the first stage USB hub that is closest to  
the computer. If you use the second or  
later hub stages, the scanner may not  
operate correctly.  
If you connect the scanner with USB 2.0,  
it is required that the USB port and Hub  
are compliant with USB 2.0. The scan-  
ning speed may slow down if it is con-  
nected with USB1.1.  
2. Connect the other end of the cable to your per-  
sonal computer.  
Be careful not to bend the pins of the SCSI  
cable when connecting to the scanner .  
ATTENTION  
Connecting with the SCSI Inter-  
face Cable  
When using the scanner with a SCSI interface, the fol-  
lowing SCSI interface cable and SCSI card must be pur-  
chased.  
The SCSI ID initially set at the factory is [5].  
HINT  
If the SCSI ID of another SCSI device is set  
SCSI interface cable:  
to the same ID, either change the scanner's  
SCSI ID or SCSI ID of the other SCSI  
device. For details on how to change the  
SCSI ID, refer to "Setting the SCSI ID" in  
this section.  
Use a cable which complies with a 50 Pin Con-  
tact Shielded High-Density SCSI Device Con-  
nector for Ultra SCSI.  
SCSI card  
Find the recommended SCSI card information in  
the Fujitsu web site (FAQ).  
Setting the SCSI ID  
The factory initial setting for SCSI ID is [5].  
When connecting the SCSI interface  
cable, turn the scanner off. Be sure to  
connect the SCSI interface cable first ,  
and then turn on the power of the scan-  
ner and personal computer.  
ATTENTION  
1. Press the power button at least for two sec-  
onds to turn off the scanner if it is on. Discon-  
nect the AC cable from the outlet.  
2. Set the SCSI ID using the SCSI ID switch on  
the back of the scanner.  
In a SCSI daisy chain formation, con-  
nect the scanner so that it is the termi-  
nated device.  
Click  
ID No.  
0 to 7  
8, 9  
Description  
Can be set as the ID  
Works with the factory default value  
(SCSI ID = 5).  
3. Press the power button to turn on the scanner.  
When the scanner is turned ON, the SCSI ID set  
at step 2 is enabled.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Installing the Scanner  
Software  
FUJITSU TWAIN 32 Scanner Driver  
To scan documents with this scanner, you must install a  
scanner driver for operating the scanner as well as  
scanning software (hereinafter called the "application")  
for launching the driver and performing a scan.  
The scanner drivers and application provided with the  
scanner are as follows:  
FUJITSU TWAIN 32 is a TWAIN-compliant scanner  
driver.  
To use this scanner with any TWAIN-compatible  
application, install FUJITSU TWAIN 32, following the  
procedure below.  
Scanner Driver:  
Preparations  
FUJITSU TWAIN 32 (-> page 5)  
Do the following before installing the application:  
Scanning application:  
Unpack the Setup CD-ROM, but do not  
insert the Setup CD-ROM into the CD driver  
yet.  
ScandAll PRO (-> page 8)  
(Supports both FUJITSU TWAIN 32 and ISIS)  
Install either of the scanner drivers above and ScandAll  
PRO. The following sections describe the installation of  
respective drivers and the application.  
Connect the scanner correctly to your  
personal computer.  
For details on how to connect the scanner,  
In addition, this scanner is bundled with the following  
software applications. To make full use of the scanner,  
try to use them together.  
HINT  
When errors occur in the scanner, you can view  
information about what happened to the scanner  
and how to solve the problem on the screen of  
the personal computer.  
Uninstall an older version of FUJITSU  
TWAIN 32 if it is already installed on your  
personal computer.  
Image Processing Software Option  
<Trial Version> (-> page 9)  
Uninstall [Scanner Utility for Microsoft Win-  
ATTENTION  
dows] from [Add/Remove Programs] on  
the control panel.  
This is an optional application for performing  
binary image processing on scanned images.  
QuickScan ProTM  
<Trial Version> (-> page 9)  
This application complies with the ISIS standard  
and it is used for scanning images. This  
scanner is accompanied with a trial version of  
this application.  
Installing the FUJITSU TWAIN32  
Scanner Driver  
Adobe Acrobat (-> page 10)  
This is an industry-standard application used for  
creating, managing, and making use of digi-  
talized documents in PDF format.  
Screenshots taken in Windows XP are used  
as examples. The displayed windows and  
operations may slightly vary depending on  
the operating system you are using.  
HINT  
How to install drivers and applications is described  
below.  
1. Press the power button to turn on the scanner.  
2. Turn on your personal computer and log on to  
Windows.  
Be sure to log on as a user with "Adminis-  
ATTENTION  
trator" privileges.  
fi-5530C2 Image Scanner Getting Started  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3. If the scanner is automatically detected,  
[Found New Hardware Wizard] or [Add/  
Remove Hardware Wizard] dialog box will  
appear. Click the [Cancel] button to close the  
Wizard dialog box.  
After you select [Yes] for installing Error  
Recovery Guide, the [Choose Setup Lan-  
guage] dialog box appears. Select a lan-  
guage and follow the on-screen  
instructions. The Error Recovery Guide dia-  
log box is automatically displayed when the  
installation is complete. Wait until the instal-  
lation of the TWAIN driver starts.  
ATTENTION  
7. Select a language for the installation on the  
[Choose Setup Language] dialog box, and then  
click the [Next] button.  
4. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK START UP SCREEN>  
appears.  
This screen may not appear if the  
ATTENTION  
"AutoPlay" setting is set to off. In this case,  
find "Install.exe" in the CD-ROM using  
"Explore" or "My Computer" and execute  
it.  
8. Install the driver, following the on-screen  
instructions.  
9. When you see the [InstallShield Wizard Com-  
plete] dialog box, click the [Finish] button.  
5. Click [INSTALL PRODUCTS], and then click  
[TWAIN Driver].  
Depending on the state of the operating system, the  
computer will once shut down and restart. In this case,  
the computer detects the scanner when it starts up. Do  
not remove the Setup CD-ROM from the CD drive until  
the computer completely starts up again.  
6. The Error Recovery Guide Installation dialog  
box appears.  
Error Recovery Guide is an application with  
which you can view on-screen information for  
troubleshooting errors that may occur in the  
scanner. This guide helps solve problems, so  
select [Yes] to install it. You may also choose  
to install it later.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the FUJITSU ISIS  
Depending on the operating system you  
are using, you may need to do the follow-  
ing.  
Scanner Driver  
ATTENTION  
Windows 2000:  
Screenshots taken in Windows XP are  
HINT  
If you see the [Digital Signature not  
Found] dialog box, click the [Yes] button.  
Windows Vista:  
used as examples. The displayed windows  
and operations may slightly vary depending  
on the operating system you are using.  
If you see the [Found New Hardware] dia-  
log box, select [Locate and install driver  
software], and then in the [User Account  
Control] dialog box, click the [Continue]  
button, if it is displayed.  
1. Press the power button to turn on the scanner.  
2. Turn on your personal computer, and then log  
on to Windows..  
The installation of FUJITSU TWAIN 32 is complete.  
Next, install ScandAll PRO (-> page 8).  
Be sure to log on as a user with "Adminis-  
ATTENTION  
trator" privileges.  
To make sure that FUJITSU TWAIN 32 is  
ATTENTION  
successfully installed, perform a scan with  
a TWAIN-compliant application such as  
ScandAll PRO. For information about how  
to scan with ScandAll PRO, refer to sec-  
3. When the scanner is automatically detected,  
[Found New Hardware Wizard] or [Add/  
Remove Hardware Wizard] dialog box will  
appear. Click the [Cancel] button to close the  
Wizard dialog box.  
FUJITSU ISIS Scanner Driver  
FUJITSU ISIS is an ISIS-compliant scanner driver.  
To use this scanner with any ISIS-compatible  
application, install FUJITSU ISIS, following the proce-  
dure below.  
Preparations  
Do the following before installing the application:  
4. Insert the "Setup CD-ROM" into the CD drive.  
<SETUP DISK START UP SCREEN>  
Unpack the Setup CD-ROM, but do not  
insert the Setup CD-ROM into the CD driver  
yet.  
appears.  
Connect the scanner correctly to your per-  
The [SETUP DISK START UP SCREEN]  
ATTENTION  
sonal computer.  
may not appear if the "AutoPlay" setting is  
set to off. In this case, find "Install.exe" in  
the CD-ROM using "Explore" or "My Com-  
puter" and execute it.  
For details on how to connect the scanner,  
HINT  
fi-5530C2 Image Scanner Getting Started  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Click [INSTALL PRODUCTS], and then click  
[ISIS Driver].  
Your computer will restart and detect the scanner. Do  
not remove the Setup CD-ROM from the CD drive until  
your personal computer completely starts up again.  
Depending on the operating system you  
ATTENTION  
are using, you may need to do the follow-  
ing.  
Windows 2000:  
If you see the [Digital Signature not  
Found] dialog box, click [Yes].  
Windows Vista:  
If you see the [Found New Hardware] dia-  
log box, select [Locate and install driver  
software], and then in the [User Account  
Control] dialog box, click the [Continue]  
button, if it is displayed.  
6. Error Recovery Guide Installation dialog box  
appears.  
Error Recovery Guide is an application with  
which you can view on-screen information for  
troubleshooting errors that may occur in the  
scanner. This guide helps solve problems, so  
select [Yes] to install it. You may also choose  
to install it later.  
The installation of FUJITSU ISIS is complete.  
Next, install ScandAll PRO.  
To make sure that FUJITSU ISIS is suc-  
ATTENTION  
cessfully installed, perform a scan with a  
TWAIN-compliant application such as  
ScandAll PRO. For information about how  
to scan with ScandAll PRO, refer to sec-  
After you select [Yes] for installing Error  
ATTENTION  
Recovery Guide, the [Choose Setup Lan-  
guage] dialog box appears. Select a lan-  
guage and follow the on-screen  
instructions. The Error Recovery Guide  
dialog box is automatically displayed when  
the installation is complete. Wait until the  
installation of the ISIS starts.  
ScandAll PRO  
Installing ScandAll PRO  
7. Select a language for the installation on the  
[Choose Setup Language] dialog box, and then  
click the [Next] button.  
ScandAll PRO is software for scanning images, which is  
in conformity with both TWAN/ISIS standards. Using  
FUJITSU TWAIN 32 or FUJITSU ISIS together with  
ScandAll PRO allows you to create document images.  
Be sure to log on as a user with "Adminis-  
ATTENTION  
trator" privileges.  
1. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK START UP SCREEN>  
appears.  
2. Click [INSTALL PRODUCTS], and then click  
[ScandAll PRO].  
8. Install the driver, following the on-screen  
instructions.  
3. Select a language for the installation on  
[Choose Setup Language] dialog box, and then  
click the [OK] button.  
9. When you see the [InstallShield Wiizard Com-  
plete] dialog box, click the [Finish] button.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Proceed with the installation, following the on-  
screen instructions.  
ner. Follow the procedure below to install the trial ver-  
sion of QuickScan ProTM that comes with this scanner.  
5. When the [InstallShield Wizard Complete] dia-  
log box appears, click the [Finish] button.  
Be sure to log on as a user with "Adminis-  
ATTENTION  
trator" privileges.  
For information about the features of Scan-  
HINT  
dAll PRO, refer to Help topics in ScandAll  
PRO.  
1. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK STARTUP SCREEN>  
appears.  
2. Click [INSTALL PRODUCTS], and then click  
[QuickScan Pro (Trial)].  
Error Recovery Guide  
If Error Recovery Guide is installed on your computer,  
you can troubleshoot errors that may occur in the scan-  
ner by simply following the on-screen instructions .  
If you did not install Error Recovery Guide together  
with the scanner driver, follow the procedure below to  
install it.  
3. In the [Welcome to the InstallShield Wizard for  
QuickScan 4.5] dialog box, click the [Next] but-  
ton.  
4. Type in necessary information in the [Customer  
Information] dialog box, and then click the  
[Next] button.  
1. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK STARTUP SCREEN>  
appears.  
2. Click [INSTALL PRODUCTS], and then click  
[Error Recovery Guide].  
3. Select a language for the installation in the  
[Choose Setup Language] dialog box, and then  
click the [OK] button.  
4. Install the application, following the on-screen  
instructions.  
5. When you see the [InstallShield Wiizard Com-  
plete] dialog box, click the [Finish] button.  
TM  
"QuickScan Pro " included in the Setup  
ATTENTION  
CD-ROM is a trial version that can be exe-  
cuted for limited number of times. You can  
run this trial version up to 30 times before  
it is disabled. If you wish to use this prod-  
uct, please consider purchasing full ver-  
sion. (When you install the trial version,  
use the displayed Serial Number.)  
Image Processing Software Option  
(Trial)  
For details on the installation of Image Processing Soft-  
ware Option (Trial Version), refer to the "Image Pro-  
cessing Software Option USER’S GUIDE."  
5. Install the application, following the on-screen  
instructions.  
QuickScan Pro™ (Trial)  
For information about the features and  
HINT  
TM  
operations of QuickScand Pro , refer to  
QuickScan ProTM is image capturing software based on  
the ISIS standard. By using this software together with  
FUJITSU ISIS, you can scan documents with the scan-  
"QuickScan Overview" or "QuickScan  
Help."  
Form the [start] menu, select [All Pro-  
grams] -> [EMC Captiva] -> [QuickScan],  
and then select a desired file.  
fi-5530C2 Image Scanner Getting Started  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
4. Install the application, following the on-screen  
instructions.  
®
®
Adobe Acrobat  
For information about how to install Adobe  
Acrobat, refer to "Read Me" that you can  
view when [Readme] is clicked in the dia-  
log box shown in step 2.  
HINT  
Install Adobe Acrobat from the "Adobe Acrobat CD-  
ROM" provided with this scanner.  
For information about how to operate  
Adobe Acrobat, refer to the Help topics in  
Adobe Acrobat.  
Adobe Acrobat is a prerequisit for display-  
ing manuals.  
HINT  
* You do not have to install Adobe Acrobat  
if it is already installed on your computer.  
Notes for using Adobe Acrobat  
ATTENTION  
1. Insert the Adobe Acrobat CD-ROM into the  
CD-ROM drive.  
When scanning a paper document and  
converting the image to PDF using Adobe  
Acrobat, unexpected images may be out-  
put when:  
The [Adobe Acrobat] dialog box appears.  
1. Setting "Edge Shadow Removal" in Acro-  
bat, and setting "Digital Endorser" or  
"Black Background" options in the  
TWAIN driver at the same time. Letter  
strings embedded in the image or the  
background may be missed.  
This dialog box may not appear if the  
ATTENTION  
"AutoPlay" setting is set to off. In this case,  
find "AutoPlay.exe" in the CD-ROM using  
"Windows Explorer" or "My Computer" and  
execute it.  
Solution 1: Set "Edge shadow removal"  
to "OFF" or set any option other than  
"Adaptive" for "Color/Grayscale" and/or  
"Monochrome" under "Compression" by  
selecting [File]->[Create PDF]-> [From  
Scanner...]-> [Optimization Options] in  
Acrobat.  
2. In the dialog box below, click the folder icon;  
installation starts and the Setup dialog box  
appears.  
Solution 2: Adjust the scanning density  
in the TWAIN driver.  
2. Setting "Adaptive" for "Color/Grayscale"  
and/or "Monochrome" under "Compres-  
sion" in Acrobat and scanning in a reso-  
lution lower than the resolution  
recommended for Acrobat.  
Solution: Set OPTION to something  
other than "Adaptive" under "Compres-  
sion."  
3. Scanning a document longer than the  
double letter (11x17) or A3 size, when  
setting "Overscan" in the TWAIN driver,  
the scan may fail.  
Solution: When scanning a double letter  
(11x17) or A3 size of document, do not  
set "Overscan" in TWAIN driver.  
3. In the dialog box below, click the [Next] button.  
4. *As for detailed usage and information of  
Acrobat, refer to "Create a PDF file from  
a scanned document" in Acrobat Help.  
Support and User registration for Adobe  
ATTENTION  
products  
For details, refer to the technical support  
information stored in the [Customer Sup-  
port] folder on Adobe Acrobat CD-ROM.  
(Note that free person-to-person support is  
not available for this is bundled product.)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6. In ScandAll PRO, select [Scan] on the menu,  
and then select [Select Scanner].  
2.4 Checking Scanner Driver  
Operation  
This section explains how to check the operation of the  
installed scanner driver by using ScandAll PRO.  
Make sure that the scanner driver is installed properly,  
following the procedure below.  
Checking the Operation of the  
Scanner Driver  
7. Select a scanner in the displayed dialog box.  
1. Load the document on the scanner.  
To use FUJITSU TWAIN 32:  
Select "FUJITSU fi-5530C2dj," and then click the  
[Select] button.  
For information about how to load the document,  
refer to section 1.2 in fi-5530C2 Operator's  
Guide.  
2. Launch ScandAll PRO.  
From the [start] menu, select [All Programs] ->  
[ScandAll PRO] -> [ScandAll PRO].  
ScandAll PRO starts up.  
3. In ScandAll PRO, select [Tool] on the menu,  
and then select [Preferences].  
To use FUJITSU ISIS:  
Select "Fujitsu fi-5530C2" and then click the  
[Select] button.  
The [Setup] dialog box appears.  
4. On the [Scan] tab, select a driver.  
To check the operation of FUJITSU TWAIN 32,  
select "TWAIN."  
To check the operation of FUJITSU ISIS, select  
"ISIS."  
8. Select [Scan] on the menu, and then select  
[Scan Settings].  
5. Click the [OK] button to close the [Setup] dialog  
box.  
fi-5530C2 Image Scanner Getting Started  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. In the [Scan Settings] dialog box, clear the  
[Save to file] checkbox.  
To use FUJITSU ISIS  
On the dialog box below, configure scanning set-  
tings, and then click the [OK] button.  
You are returned to the [Scan Settings] dialog  
box.  
12. Click the [Scan] button.  
When you are using FUJITSU TWAIN 32,  
HINT  
you may see the TWAIN Driver setup dia-  
log box again. If so, click the [Scan] button  
on the dialog box.  
You only check the operation now, so you  
do not have to save to file.  
HINT  
The document is scanned and the scanned  
image is displayed in the [ScandAll PRO]  
window.  
10. Click [Scanner Settings].  
A setup dialog box appears for you to config-  
ure scanner driver settings.  
11. Configure scanner settings such as the resolu-  
tion and paper size.  
To use FUJITSU TWAIN 32  
On the dialog box below, configure scan settings,  
and then click the [OK] button.  
If the scanned document image is displayed in the win-  
dow, it means that the scanner driver is installed prop-  
erly.  
For further information about how to scan documents,  
refer to "fi-5530C2 Operator’s Guide" contained in the  
Setup CD-ROM.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Click the [Change/Remove] button or the  
[Remove] button.  
2.5 Uninstalling Supplied  
Programs  
6. When you see a confirmation dialog box, click  
the [OK] button or the [Yes] button.  
The following explains how to uninstall software appli-  
cations provided with the scanner.  
Upon clicking the button, uninstallation is  
started.  
Screenshots taken in Windows XP are used  
HINT  
as examples. The displayed windows and  
operations may slightly vary depending on  
the operating system you are using.  
Displays may vary depeinding on the oper-  
ating system you are using. Follow the on-  
screen instructions.  
HINT  
Examples  
In Windows 2000, the window and button  
names described above are as follows:  
1. Start your personal computer.  
[Add or Remove Programs] -> [Add/  
Remove Applications]  
Be sure to log on as a user with "Adminis-  
trator" privileges.  
ATTENTION  
The [Changel/Remove] button -> The  
[Add/Remove] button  
In Windows Vista, the window and button  
names described above are as follows:  
[Uninstall or Change a program] ->[Unin-  
stall or Change]  
2. Exit all applications.  
3. From the [Start] menu, select [Control Panel] ->  
[Add or remove Programs].  
In the [Add or remove Programs] dialog box,  
you can view a list of installed applications.  
4. Select an application you want to uninstall as  
follows:  
To remove FUJITSU TWAIN 32,  
select "Scanner Utility for Microsoft Win-  
dows."  
To remove ScandAll PRO,  
select "Fujitsu ScandAll PRO V1.0."  
To remove FUJITSU ISIS,  
select "Fujitsu ISIS Drivers."  
To remove Error Recovery Guide,  
select "Error Recovery Guide."  
To remove Software Operation Panel, (Software  
Operation Panel is automatically installed  
together with FUJITSU TWAIN 32/ISIS),  
select "Software Operation Panel."  
To remove QuickScan ProTM  
select "QuickScan"  
,
For information about how to uninstall  
Image Processing Software Option (Trial  
version), refer to "Image Processing  
Software Option User’s Guide."  
HINT  
For information about how to uninstall  
Adobe Acrobat, refer to Adobe Acrobat  
"Read Me."  
fi-5530C2 Image Scanner Getting Started  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix1 TROUBLESHOOTING  
Troubleshooting checklist  
Symptom  
Check this item  
Remedy  
Push the power button.  
The scanner is not turned on. Have you pushed the power button?  
Are the AC cable and AC adapter prop-  
erly connected to the scanner?  
Correctly connect the AC cable and the AC  
adapter.  
Disconnect the AC cable and the AC adapter from  
the scanner, then connect them again.  
If this does not restore the power supply, contact  
the store where you purchased the scanner or an  
authorized FUJITSU scanner service provider.  
Is Windows normally started up?  
Push the power button again after completely  
starting up Windows.  
Scanning does not start.  
Are the documents loaded correctly on  
the ADF paper chute?  
Load the document correctly on ADF paper chute.  
Is the ADF closed completely?  
Close the ADF completely.  
Is the USB cable or SCSI cable properly Correctly connect the cable. (When a USB hub is  
connected? used, check the hub's power supply.)  
(When using SCSI interface) Is SCSI ID Set SCSI ID correctly by SCSI ID switch on rear  
set correctly? of scanner.  
Does the Function Number Display indi- When the Function Number Display indicates an  
cates an alarm or an error?  
alarm or an error, refer to chapter 5 "TROUBLE-  
SHOOTING" of "fi-5530C2 Operator’s Guide"  
for removing the alarm or the error.  
Does the alarm state remain displayed  
even after the scanner has been turned  
off and back on again?  
Turn off and on the power button.  
If this does not eliminate the alarm state, contact  
the store where you purchased the scanner or an  
authorized FUJITSU scanner service provider.  
Vertical lines appear in the  
generated image.  
Is the glass dirty?  
Clean the glass following the instructions in chap-  
ter 3 "Daily Care" of "fi-5530C2 Operator’s  
Guide."  
The generated image is  
skewed or distorted.  
Are the documents loaded correctly?  
Load the documents correctly.  
The generated image qual-  
ity is not good enough.  
Are the glass or sheet guides (a white  
location) clean?  
Clean dirty locations.  
Multi-feed errors occur fre-  
quently.  
Do the documents satisfy the "Docu-  
ment Quality" and the "Multi feed  
Detection Conditions" in the chapter 6  
of "fi-5530C2 Operator’s Guide"?  
Use the documents that satisfy the "Document  
Quality" and the "Multi feed Detection Condi-  
tions" in the chapter 6 of "fi-5530C2 Operator’s  
Guide"  
Are the documents set properly in the  
ADF paper chute?  
Fan the documents before scanning. Correctly  
align the document stack and load them on the  
ADF paper chute. For details, refer to section 2.1  
Is the document stack thicker than  
10mm?  
Reduce the number of sheets in the document  
stack to 10 mm thickness or less.  
Is the Pad ASSY dirty?  
Clean the Pad ASSY. For details, refer to section  
3.2 "Cleaning the ADF" of "fi-5530C2 Operator's  
Guide."  
Is the Pad ASSY worn out?  
Replace the Pad ASSY. For details, refer to sec-  
tion 4.2 "Replacing the Pad ASSY" of "fi-5530C2  
Operator's Guide."  
AP-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Symptom  
Check this item  
Remedy  
Paper is not fed (pick error  
occurs frequently, or docu-  
ment stops midway).  
Do the documents satisfy the "Docu-  
ment Quality" and the "Multi feed  
Detection Conditions" in the chapter 6  
of "fi-5530C2 Operator’s Guide"?  
Use the documents that satisfy the "Document  
Quality" and the "Multi feed Detection Condi-  
tions" in the chapter 6 of "fi-5530C2 Operator’s  
Guide."  
Is the Pick roller dirty?  
Clean the Pick roller. For details, refer to section  
3.2 "Cleaning the ADF"of "fi-5530C2 Operator's  
Guide."  
Is the Pick roller worn out?  
Clean the Pick roller. For details, refer to section  
4.3 "Replacing the Pick Roller" of "fi-5530C2  
Operator's Guide."  
Is there any debris on the document feed Remove any debris from the document feed path.  
path?  
The generated images are  
elongated.  
Are the Feed rollers dirty?  
Have you adjusted the scan scale?  
Are the Feed rollers dirty?  
Clean the Feed rollers. For details, refer to section  
3.2 "Cleaning the ADF"of "fi-5530C2 Operator's  
Guide."  
Select "Scanners and Cameras" in the control  
panel, then click the [Device Set] tab to adjust  
scale.  
There is a shadow on the  
leading edge of the gener-  
ated image?  
Clean the Feed rollers. For details, refer to section  
3.2 "Cleaning the ADF"of "fi-5530C2 Operator's  
Guide."  
Have you adjusted the offset (the scan-  
ning starting position)?  
Adjust the [Sub-scan Setting] on [Scanners and  
Cameras] in the control panel.  
fi-5530C Image Scanner Getting Started  
AP-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temporary error  
Device alarm (Permanent error)  
Indication  
Meaning  
Indication  
E2  
Meaning  
U1  
U2  
U6  
A paper feed error occurred.  
A multi feed error occurred.  
The print cartridge is not set.  
Trouble in the optical system (front).  
Trouble in the optical system (back).  
The motor fuse has blown out.  
Trouble in the operator panel.  
E3  
E4  
E6  
E7  
The following shows the procedure for releasing of each  
temporary error.  
Trouble occurred in the internal memory  
(EEPROM).  
E8  
E9  
Ec  
Ed  
EF  
The SCSI interface fuse has blown out.  
An error in the image memory.  
An alarm in the memory.  
"U1" error  
1. Remove jammed documents.  
(For details, refer to section 5.1 "Removing  
Jammed Documents" of "fi-5530C2 Opera-  
tor’s Guide on the Setup CD-ROM..)  
2. Confirm that the documents meet the paper  
conditions for scanning.  
Trouble in the SCSI interface controller.  
A trouble in the Background switching  
mechanism.  
(For details, refer section 6.2 "Document  
Quality" of "fi-5530C2 Operator’s Guide" on  
the Setup CD-ROM.)  
When you encounter any alarm, turn off and on the  
scanner. If the alarm is still displayed on the Function  
Number Display, contact the store where you purchased  
the scanner or an authorized FUJITSU scanner service  
provider.  
"U2" error  
Press the [Send to] button on the Operator Panel.  
The papers that were multi fed will be ejected.  
"U6" error  
This is a temporary error related with the  
Imprinter option (sold separately). For details,  
refer to chapter 5 "Error Message" of "fi-553PR  
Operator's Guide."  
AP-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix2 DAILY CARE  
Locations and Cycle for Cleaning  
When operating the scanner, the  
ADF’s inside glass becomes very  
hot.  
Before you clean inside the scan-  
ner, turn off its power and unplug  
the AC adapter from the outlet. Wait  
for at least 15 minutes.  
Do not turn off the scanner when  
you clean the Feed rollers or Eject  
rollers.  
Part to clean  
Pad ASSY  
Standard Cleaning Cycle  
Clean these parts after every  
5,000 scans.  
Pick roller  
Feed rollers  
Plastic rollers  
Eject rollers  
Sheet guides  
Glass  
Cleaning Materials  
Ultra sonic sensor  
Cleaning  
Materials  
Parts No.  
Remarks  
1 bottle  
Moisten a cloth with  
this fluid and wipe the  
scanner clean.  
The scanner must be cleaned more fre-  
quently if you scan any of the following  
type of sheets:  
ATTENTION  
Cleaner F1  
PA03950-  
0352  
Documents of coated paper  
Documents that are almost completely  
covered with printed text or graphics  
Chemically treated documents such  
as carbonless paper  
Documents containing a large amount  
of calcium carbonate  
Lint-free dry  
cloth  
- Commercially available one  
For details about the cleaning materials, contact the  
FUJITSU scanner dealer where you purchased the scan-  
ner.  
Documents written by pencil  
Documents on which the toner is not  
fused sufficiently.  
Cleaning Method  
For details on the cleaning the ADF, refer to section 3.2  
"Cleaning the ADF" of "fi-5530C2 Operator’s Guide"  
on the Setup CD-ROM."  
The ADF must be cleaned with a lint-free cloth moist-  
ened with the Cleaner F1.  
It may take long before the cleaner  
ATTENTION  
vaporizes if a large quantity is used.  
When cleaning the scanner parts,  
dampen a cloth with modest quantities  
of the cleaner. In addition, wipe off the  
cleaner completely with a soft lint-free  
cloth to leave no residue on the surface  
of the cleaned parts.  
fi-5530C Image Scanner Getting Started  
AP-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix3 REPLACING CONSUMABLES  
The following illustrations show the locations of the  
During its operation, the inside  
consumables. For details, refer to chapter 4 "Replacing  
Consumables" of "fi-5530C2 Operator’s Guide" on the  
Setup CD-ROM.  
glass of the ADF becomes very  
hot .  
Before replacing the  
consumables, turn its power off  
and unplug the AC adapter from  
the outlet. Wait at least  
15 minutes.  
Replacing the Pad ASSY  
To remove  
To attach  
Consumables and Replacement  
Cycle  
The followings are the specifications of consumables  
and their recommended replacement cycles.  
Pad ASSY  
Standard  
Replacement Cycle  
Description  
Parts No.  
Replacing the Pick Roller  
Pad ASSY  
PA03334-  
0002  
After 100,000 scans or  
one year  
Sheet guide  
Pick roller  
PA03334-  
0001  
After 200,000 sheets  
or one year  
To purchase consumables, contact the store where you  
purchased the scanner or an authorized FUJITSU scanner  
service provider.  
The replacement cycles above are rough guidelines  
when using A4/Letter woodfree or wood containing  
paper 64 g/m2 (17 lb). This cycle varies according to the  
type of the used paper and how frequently the scanner is  
used and cleaned.  
Use only the specified consumables.  
ATTENTION  
Pick roller  
AP-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
fi-5530C Image Scanner Getting Started  
AP-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-5530C2 Image Scanner Getting Started  
P3PC-1932-01EN  
Issue Date: June, 2007  
Issued by: PFU LIMITED  
z Copying of the contents of this manual in whole or in part and  
copying of the scanner application is prohibited under the  
copyright law.  
z The contents of this manual are subject to change without notice.  
z PFU LIMITED is not liable whatsoever for any damages resulting  
from use of this scanner and procedures described in this manual,  
profit loss due to defects, and any claims by a third party.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki CRT Television LC XWP2000 User Manual
Festool Saw KS 120 User Manual
Flying Mole Stereo Amplifier CAS10 User Manual
Fujitsu All in One Printer DL700 User Manual
Garmin GPS Receiver Vista C User Manual
GE Cordless Telephone 16223870 User Manual
GE Dishwasher GDF510 540 Series User Manual
GE Microwave Oven JVM60 User Manual
Generac Power Systems Portable Generator 4703 User Manual
George Foreman Fryer SKG01GFB User Manual