OWNER’S GUIDE
READ AND SAVE THESE INSTRUCTIONS
Record Model No. and Serial No. of this dehumidifier in space provided below. These numbers are
printed on the nameplate located behind the bucket.
Model No. ___________________________________________________
Serial No.____________________________________________________
IMPORTANT: Keep a copy of your bill of sale. The date on the bill establishes the warranty period
should service be required. If service is performed, it is in your best interest to obtain and keep all
receipts.
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed, and
returned to the Frigidaire Company.
Contents
2
Warranty
3
3
Important Safety Instructions
Location
3
How It Works
4
Operating Steps
4-5
5-6
6
Dehumidifier Features
Removing Collected Water
Care and Cleaning
Avoid Service Checklist
7
Operate dehumidifier only as instructed in this Owner’s Guide. These instructions are not meant to
cover every possible condition and situation that may occur. Common sense and caution must be
used when installing, operating, and maintaining any appliance.
DEHUMIDIFIER
P/N 327000009 (0011)
Download from Www.Somanuals.com. All Manuals Search And Download.
Read all instructions before using this dehumidifier. To reduce the risk of fire,
electric shock, or injury to persons when using your dehumidifier, follow basic
precautions, including the following:
Important Safety
Instructions
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance. Read product labels for flammability and other warnings.
Child Safety Precautions
Avoid fire hazard or
• Destroy the carton, plastic bags, and any packing materials immediately after the
dehumidifier is unpacked. Children should never use these items for play.
• Do not leave children unattended in an area where the appliance is operating.
• Do not allow them to sit or stand on the appliance.
electric shock. Do not use an extension
cord or an adaptor plug. Do not remove
grounding prong from power cord.
Grounding type
wall receptacle
Electrical Information
• For your safety and protection, this dehumidifier is equipped with a three-prong
grounding plug on the power cord. Do not, under any circumstances, cut or
remove the round ground prong from the plug.
Do not, under
any circumstances,
cut, remove,
or bypass the
• Your dehumidifier must be plugged directly into a properly grounded and
polarized three-prong receptacle. If the wall receptacle you intend to use will not
accept a three-prong plug, or if you are not sure the outlet is adequately
grounded or protected by a time delay fuse or circuit breaker, have a qualified
electrician install the proper outlet according to the National Electrical Code and
applicable local codes and ordinances. Do not use an extension cord or an
adapter plug.
grounding prong
from this plug.
• Never unplug the dehumidifier by pulling on the power cord. Always grip the
plug firmly and pull straight out from the receptacle.
• Do not pinch, bend, or knot the power cord.
Selecting a Location
IMPORTANT:
Location
1. Dehumidifier must be operated in an enclosed area to be most effective.
Close all doors, windows, and other outside openings to the room. The
effectiveness of the dehumidifier depends on the rate at which new
moisture-laden air enters room.
2. Place dehumidifier in a location that does not restrict airflow through the
front of the unit or out of the louvers on the left side of cabinet.
3. A dehumidifier operating in a basement will have little or no effect in
drying an adjacent enclosed storage area, such as a closet, unless there
is adequate circulation of air in and out of the area. It may be necessary
to install a second dehumidifier in the enclosed area for satisfactory
drying.
When the unit is started, the fan begins to pull moisture-laden air across the
dehumidifying coils. The coils condense or draw moisture from the air, and air flows
through the side louvers into the room as dry, warm air. Moisture removed from air
is collected in a bucket on the front of the dehumidifier.
How It Works
© 1996 White Consolidated Industries, Inc.
All rights reserved.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
The bucket has a hose/drain connection. The dehumidifier should be kept in
operation as long as excess moisture is present in the room air.
Operating Steps
To begin operating the dehumidifier, follow these steps:
1. Plug the power cord into a properly grounded 110/120 volt AC outlet.
Note: Before operating this unit, see the “Removing Collected Water” section
for proper placement of the bucket. Model will not operate if the bucket is not
properly positioned in the unit.
2. When first using the dehumidifier, turn the Humidistat Control clockwise to the
MAX.DRY position. The unit will run continuously at this setting.
3. Press the Fan Speed Button to HI. The HI setting is recommended for faster
moisture removal.
4. Allow the dehumidifier to operate at the above settings for three to four days.
After this time, adjust the controls as needed. See below.
Humidistat Control
Dehumidifier Features
The Humidistat Control automatically starts dehumidifier when humidity is
excessive. When humidity has been reduced to the comfort level set on the control,
the unit turns off.
When first using dehumidifier, turn Humidistat Control clockwise to MAX.DRY. Unit
will run continuously at this setting. Operate dehumidifier at the MAX.DRY setting
for three to four days. During this time, observe the dampness conditions in the
area being dried. When the sweating has stopped and the dampness odors are
gone, adjust Humidistat Control to the position between OFF and MAX.DRY that
provides a “dryness” condition suitable to your needs/comfort.
Fan Speeds
The Fan Speed adjusts fan speed. When humidity has been reduced to the desired
level and quiet operation is preferred, press Fan Speed to LO.
Moisture Removal
At first, the dehumidifier will remove large amounts of moisture. It will continue to
do so until the relative humidity is reduced to a point where moisture damage will
not occur. Then, the amount of moisture removed from the air will be a lot less. This
indicates the dehumidifier is operating effectively and is maintaining the relative
humidity at the desired level. Judge the performance of the dehumidifier by the
elimination of dampness and dampness odors, not by the amount of water being
deposited in the bucket. When bucket has filled with water, unit will turn off. All
models feature an Automatic Shut-Off light that will glow until bucket is emptied
and returned to the proper position.
Operating Conditions
All models will operate if the room teperature is greater than 65°F (18°C). Models with
a moisture removal capacity greater than 40 pints per 24 hours will operate satisfactorily
at a temperature no lower than 50°F (10°C). If conditions less than those stated or the
humidity is low the dehumidifier should be turned off. See “Frost Control”.
(Hi-Speed)
(Low-Speed)
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Conditions (Continued)
Dehumidifier Features
A dehumidifier will not eliminate frost on windows during winter. The dehumidifying coil
normally operates above freezing temperatures and cannot prevent moisture from
condensing on the inside of a window pane that is below freezing.
(continued)
TIP: It may be helpful to use a dehumidifier in the kitchen or laundry area where
the humidity is high. Reducing humidity in these areas may reduce frost on
windows in other parts of the home.
Frost Control
The Frost Control feature prevents frost or ice from remaining on the dehumidifying
coil for an extended period of time. When frost formation occurs, this control turns
off the compressor. The fan continues to run, causing any frost or ice to melt.
Dehumidifier will then resume normal operation.
Frost Control is also designed to prevent excessive on-off cycling. Under certain
conditions this may allow frost to remain on coil for some time before the
compressor turns off and the frost is cleared.
Bucket and Float Installation
Removing Collected
Water
All models are supplied with a bucket, which is conveniently tucked into the front
of the unit to accumulate water removed from the air, or use the built-in hose
connection to carry water directly to a drain.
When using the bucket the Automatic Shut-Off switch is activated by a float. The
Automatic Shut-Off switch stops the unit before the bucket overflows, and turns
the unit on again after the bucket is emptied and replaced.
The bucket and float must be installed correctly for proper operation (Figure 1).
Figure 1
1. Grasp bucket from both sides at the bottom, gently lift up and slide halfway out
until handle is exposed. See Figure 2.
2. Grab handle and slide bucket away from unit. See Figure 3.
3. After emptying the collected water, slide bucket back into place.
4. Be sure bucket is in place.
Bucket Removal
Figure 3
5
Figure 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Direct Draining
Direct Draining
If you want the water to flow directly to a drain, you must first remove the hose cap
(Figure 2). To remove hose cap, use a standard screwdriver and turn counter-
clockwise. Connect any standard garden hose to the bucket connection, or
place the dehumidifier over the drain. A standard garden hose has a 3/4”
1
2
(19 mm) diameter connection with 11 ¼ inch threads per inch.
Note: When using either of the above direct draining methods, you must first drill
a 3/8” (10 mm) hole in the center of the bucket connection. (For ease of drilling use
locating mark to center drill bit for hole (Figure 3).) This will allow water to flow
freely through the connection. To reseal the hose connection to the bucket, use any
standard hose end cap. The hose cap cannot be used to reseal the hole.
Locating
Hole
Figure 5
Figure 4
Proper Care
Before cleaning, be sure to turn off and unplug unit.
Care and Cleaning
1.
2.
Dust outer cabinet with an oil-free cloth, or wash with warm water.
Use a vacuum cleaner and brush attachment to clean grill.
Note: Fan motor has been permanently lubricated at the factory.
Air passing through dehumidifier may carry quantities of dust, lint and fungus
spores. Much of this matter will be deposited on the coil and then flushed away
by natural drainage.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Before calling for service, review this list. It may save you time and expense. This
list includes common occurrences that are not the result of defective workman-
ship or materials in this appliance.
Avoid Service Checklist
OCCURRENCE
SOLUTION
DEHUMIDIFIER DOES NOT OPERATE.
Plug is disconnected from outlet. Push plug firmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit
breaker.
The dryness level you selected has been reached. Dehumidifier automatically shuts off when
selected amount of moisture has been removed from the air. If you want to remove more
moisture, turn the Humidistat Control to MAX.DRY. After the dehumidifier starts, reset the
control to the desired setting.
Bucket not installed properly. See “Removing Collected Water.”
Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this
occurs. Empty bucket and return bucket to position.
Dehumidifier is not turned on. Turn the Humidistat Control to MAX.DRY.
DEHUMIDIFIER RUNS TOO MUCH.
Windows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside.
Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate.
Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of
vacuum cleaner to clean grill. See “Care and Cleaning.” Dehumidifier must be placed in a space
that does not restrict air flowing into the rear coil or out of the front grill.
Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the
longer the dehumidifier will operate.
Humidistat Control is set at MAX.DRY. Dehumidifier will not turn off if Humidistat Control
is at MAX.DRY.
DEHUMIDIFIER IS OPERATUNG BUT
ROOM IS NOT DRY ENOUGH.
Humidistat Control is set too low. Turn the Humidistat Control to a higher setting.
Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the
longer it takes for the room air to become dry.
Dehumidifier does not have sufficient clearance to operate. Air flow to front grill is blocked. See
“Selecting a Location.”
Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below
65°F (18°C). See “Operating Conditions.”
Refer to causes under DEHUMIDIFIER RUNS TOO MUCH.
FROST APPEARS ON COILS ABOVE
BUCKET OR DRIP TRAY.
Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the
coil. Frost will usually disappear within 60 minutes.
Room Temperature is too low. All models will operate satisfactorily at temperatures greater than
65° F (18°C). Models with a moisture removal greater than 40 pints per 24 hours will operate
satisfactorily at a temperature no lower than 50°F (10°C). See “Operating Conditions”.
NOISE IS LIKE A FAN.
Air is moving through the dehumidifier. This is a normal sound.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CERTIFIED RATING
WATER REMOVAL
When the actual seal is affixed to a dehumidifier and the water removal capacity rating for
that dehumidifier appears in the AHAM Certification Directory, it signifies that the rating
is certified by Frigidaire Company and verified by the Association of Home Appliance
Manufacturers as complying with American National Standard B149.1.
AHAM
association of home
appliance manufacturers
Manufacturer Certified to ASSOCIATION
OF HOME APPLIANCE MANUFACTURERS
ANSI/AHAM DH-1-1992
®
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|