Built-In Downdraft Cooktop
RC30DG60PS
30" Gas
Product Dimensions
Width
30"
Depth
21-13/32"
Height (Min.)/(Max.)
17-13/16"/ꢀ23-3/8"
More Easy-To-Use Features
Low Simmer Burner
Perfect for delicate foods and sauces.
Stainless Steel Recessed Cooktop
3 Ducting Options
Dishwasher-Safe Filter
Available in:
Stainless
(S)
Burners
BTU
Right Front
Right Rear
Left Front
Left Rear
12,000
5,000
9,500
17,000
Signature Features
Downdraft System
PowerPlus® Boil
17,000 BTU sealed burner boils
water faster.
Whisks away odors and smoke without
the need for overhead ventilation.
Pro-Select® Controls
Continuous Grates
Precise control at your fingertips.
Continuous grates make it easy to
move heavy pots and pans between
burners without lifting.
frigidaire.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Built-In Downdraft Cooktop
RC30DG60PS 30" Gas
30" Gas Cooktop
with Ventilation Unit
For ventilation unit ductwork preparation
and installation planning information, refer to
30" min. for
30" Gas Cooktop Ductwork Preparation page.
unprotected
30"
cabinet bottom
24" min.
Rear Discharge
Right Side View
for protected
cabinet bottom
18"
min.
2113/32"
30"
1713/16"
13"
max.
cabinet
depth
Ventilation
unit not shown
beneath cooktop.
311/16"
2613/16"
1815/16"
Down Discharge
Right Side View
13/8" minimum flat distance
from cutout edge
28"
191/8
"
9" min. to nearest
combustible wall
(each side of unit)
233/8
"
24"
13/8" minimum flat distance
from cutout edge
Built-In Cooktop Specifications
•
•
•
•
Cooktop Shipping Weight (approx.) – 89 Lbs.
Voltage Rating – 120Vꢀ/ꢀ60 Hzꢀ/ꢀ15 Amps
For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.
Amps @ 120 Volts = 15
Always consult local and national electric and gas codes.
For detailed electrical and gas supply locations, refer to
30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.
Locate cooktop between wall studs or floor joists so that ductwork
may be installed properly.
Installing cooktop into pre-existing base cabinets may require
modifications. Cabinets with drawers require drawers be removed
and drawer fronts attached to cabinet face. Verify internal length
and width of cabinet base because sides or back wall may need
cut out and corner braces removed to accommodate unit.
Countertop opening MUST be cut based on dimensions shown,
cut squarely with sides parallel to each other and with front and
rear perpendicular to cabinet sides.
Provide adequate gas supply. Cooktop ships with 3/4" factory
regulator.
LP Gas conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 36".
Allow 30" minimum clearance between top of cooktop platform
and bottom of unprotected wood or metal overhead cabinet.
Allow 9" minimum required clearance from left edge and right edge
of cooktop to nearest combustible wall on each side.
•
•
•
•
•
•
•
•
•
•
Ductwork Preparation
•
For ventilation unit ductwork preparation and planning information,
refer to 30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
•
•
Optional Accessories
•
Granite Countertop Installation Kit – (PN # 903103-9010)
Pre-formed countertops with raised lip and radius at base of
backsplash may not allow enough flat area for proper installation.
Minimum 1-3/8" distance required from rear and front edge of
cooktop cutout.
Accessories information available
on the web at frigidaire.com
•
•
•
•
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com
Specifications
subject to change.
•
•
•
•
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca
RC30DG60P 07/13
Download from Www.©So20m13aEnluecatlrso.lcuxomHo.mAellPMroaduncutsa,lIsncS. earch And Download.
Built-In Downdraft Cooktop
RC30DG60PS 30" Gas
Electrical /Gas Supply Location
30" Gas Downdraft Cooktop –
Ductwork Preparation
Countertop
surface
51/2
"
Ventilation unit comes detached from cooktop.
C
Cabinet
side wall
L
Cabinet
side wall
To ensure proper installation, refer to 30" Gas Downdraft
Cooktop Specifications page for planning information, and
installation guide on web for complete installation details
including countertop and cabinet requirements.
Electrical
Installation Note:
31/4
"
Recomm.
gas supply
stub area
Locate 120 volt,
60 Hertz, properly
grounded branch
circuit protected
by 15 amp circuit
breaker or time
delay fuse within
shaded area
Ducting Options
On floor, through floor or through wall.
4"
4"
11"
shown.
45/16"
Exhaust Outlet Locations –
Cut exhaust outlet hole in wall or
floor based on desired installation.
Exhaust duct MUST be located
between wall studs or floor joists.
Cutout
center
Cutout
center
8"
6"
6"
71/8
"
45/16"
Bottom
Exhaust Outlet
Rear Wall
Exhaust Outlet
Built-In Cooktop Ductwork Preparation
•
•
Ventilation unit comes detached from cooktop. To ensure proper
For maximum efficiency, use shortest, straightest duct run possible.
Unit operates most efficiently with up to 100 equivalent feet of duct.
(Refer to Calculating Duct Length Table in Product Installation Guide.)
Flexible ducting is not recommended due to severely restricted
airflow; if blower outlet and floor or wall duct location do NOT align,
flexible METAL ducting can be used to adapt to offset.
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold. Cold weather installations should
have additional backdraft damper installed.
installation, refer to 30" Gas Downdraft Cooktop Specifications page
for planning information, and installation guide on web for complete
installation details including countertop and cabinet requirements.
•
•
•
•
•
Ducting Options – On floor, through floor or through wall.
Ventilation Unit Discharge Options – Rear or down.
Consider ductwork location and desired installation before cutting
exhaust outlet hole in cabinet. For proper installation, cooktop
exhaust duct MUST be located between wall studs or floor joists.
•
•
Vent exhaust air outside only and NOT into any concealed space.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Exhaust Duct Required – Galvanized or aluminum duct in 6" round
or 3-1/4" x 10" rectangular, or combination of both. PVC should
be used if installing under concrete slab.
•
Local building code must be followed in specifying approved type
and schedule of ALL duct used; always use appropriate roof or
wall cap with damper.
Accessories information available
on the web at frigidaire.com
•
•
•
•
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com
Specifications
subject to change.
•
•
•
•
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca
RC30DG60P 07/13
Download from Www.©So20m13aEnluecatlrso.lcuxomHo.mAellPMroaduncutsa,lIsncS. earch And Download.
|