Air Conditionerꢀ/ꢀ
Heat Pumpꢀ/
Backup Electric Heater
PTAC
FRP12PTT2R
Product Dimensions
Height
Width
Depth
16"
42"
13-13/16"
More Easy-To-Use Features
Comfort Control Design
Simple controls allow guests to
customize their settings, while quiet,
uniform air movement keeps rooms
comfortable.
Smart Self-Check
Provides nine diagnostic points for self-
check and correction of fault conditions.
Eco-Friendly
Frigidaire® uses R-410A refrigerant that’s
not harmful to the earth’s ozone layer
and meets U.S. Environmental Protection
Agency requirements.
Effortless™ Operation
Simple, intuitive room controls are easy
for guests to operate — ensuring a
relaxing, more comfortable stay. Features
like Effortless™ Restart and Ready-Select®
controls reduce maintenance calls.
Performance
BTUs
Cool
12,000ꢀ/ꢀ11,800
10,200ꢀ/ꢀ8,300
10,700ꢀ/ꢀ10,500
Backup Electric Heater
Heat Pump
Signature Features
SilentDesign™
Sound reduction package.
Energy-Saver Option
This function effortlessly maximizes
energy efficiency while keeping guests
comfortable.
Effortless™ Maintenance
Effortless™ Temperature
Control
Frigidaire® air conditioners maintain the
preset room temperature so the room
remains comfortable at all times and
helps control energy levels.
With Frigidaire’s reputation for durability,
easy maintenance, availability of reliable
parts and service you can count on,
you can be sure that you’re getting the
highest-quality performance.
frigidaire.com
Download from Www.Somanuals.com. All Manuals Search And Download.
PTAC
FRP12PTT2R Air Conditionerꢀ/ꢀHeat Pumpꢀ/ꢀBackup Electric Heat
Rearward Slope
1/4" Slope
Acccessory
Outdoor Grille
Front Panel
Acccessory
Wall Sleeve
Outside Wall
Inside Wall
Chassis
Product Dimensions
Wall Cutout Dimensions
Height
16"
Height
Width
16-5/16"
42-3/16"
Width
42"
Depth
13-13/16"
13-13/16"
Max. Wall Thickness
Plug Type (NEMA)
6-20P
PTAC Specifications
Replacement Installation
•
•
•
•
•
Product Shipping Weight (approx.) – 135 Lbs.
When replacing existing PTAC with new unit, refer to Product
Installation Guide on web to identify existing wall-sleeve manufacturer
and size compatibility. If proper installation and slope are suspect,
then correct installation of Frigidaire® PTAC Sleeve options
recommended.
For any sleeve retrofit application, be sure that the foam seals
(factory-installed on the tube sheets) provide a good seal between
the grille and the outdoor coil tube sheets. These foam seals provide
a barrier that stops air from the inside mixing with air on the outside
(known as air recirculation).
Using Frigidaire® wall sleeve with Non-Frigidaire grille requires
installation of an Accessory Baffle Kit, which ensures a good seal
between the unit and exterior grille to prevent air recirculation. Air
recirculation is a large contributor to performance loss and premature
damage to major components.
An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
Voltage Rating – 230Vꢀ/ꢀ208Vꢀ/ꢀ60 Hzꢀ/ꢀ20 Amps
Amps @ 230/208V Volts = (Cool) 5.1ꢀ/ꢀ5.3 Ampsꢀ/ꢀ(Backup Electric
Heater) 13.2ꢀ/ꢀ12.2 Ampsꢀ/ꢀ(Heat Pump) 4.5ꢀ/ꢀ4.7 Amps
Always consult local and national electric codes.
Recommended Circuit Breaker – 20 Amps
Unit equipped with 230/208V 3-wire power supply cord, NEMA plug
type 6-20P, approximately 66" long.
In order for condensate water to drain properly inside the unit, the
sleeve must be installed properly: Level from right to left with a slight
1/4" rearward pitch from the indoor side to the outdoor side as shown
in the illustration above. Refer to the Installation Instructions on the
web.
•
•
•
•
•
•
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
*See accessories pages attached for optional accessories.
New Installation
•
For new installation, Frigidaire® PTAC Sleeves are available and
recommended for proper installation. See accessories pages for
sleeve options.*
•
PTAC installation requires 13-13/16" maximum wall thickness.
•
•
•
•
USA 10200 David Taylor Drive Charlotte, NC 28262 1-866-942-1567 frigidaire.com
Specifications
subject to change.
•
•
•
•
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-866-942-1567 frigidaire.ca
FRP12PTT2R 06/11 © 2011 Electrolux Home Products, Inc.
Printed in the U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
Packaged Terminal Air Conditioner (PTAC)
FRP12PTT2R – Cool & Heat Pump with Electric Heat Back-up, 12,000 BTU
JOB:
REFERENCE:
APPROVAL:
DATE:
CONSTRUCTION:
UNIT NUMBER:
LOCATION:
ENGINEER:
SUBMITTED TO:
DRAWING NUMBER:
SUBMITTED BY:
Dimensions
Features
• 24 Hour On/Off Timer
• Effortless™ Maintenance
• Effortless™ Protection
• Comfort Control Design
• Smart Self-Check
Height: 16˝
• SilentDesign™
Width: 42˝
Depth: 13 13/16˝
• Energy-Saver Option
• Eco-Friendly with R410a Refrigerant
• Ready-Select® Controls with
LED Temperature Display
Unit Weight:
111 Lbs.
Shipping Weight: 135 Lbs.
• Effortless™ Temperature Control
• Versatile Multi-Mode Operation
• Effortless™ Operation
• Front desk Control Ready
• Cord included (LCDI 6-20P)
• Commercial Grade Warranty
Max Wall Thickness: 13 13/16˝
Cut-Out Height:
Cut-Out Width:
16 5/16˝
42 3/16˝
• Multi-Speed Fan
PERFORMANCE
BTU (Cool)
BTU (Heat Pump)
BTU (Heat - Electric)
EER (Cooling)
COP (Heat Pump)
Dehumidification (Pints/Hr.)
Approximate Cooling Area (Sq. Ft.)
Performance Certification
Safety Certification
Commercial Grade Warranty
ELECTRICAL
SPECIFICATIONS
Refrigerant
Charge (Oz.)
Noise Level Indoors (High/Med/Low) (dB)
Air Volume (CFM) (High/Med/Low)
Motor RPM (High/Med/Low)
Air Direction Control
12,000/11,800
R410A
26.8
53/52/51
10700 / 10500
10,200/8,300
10.7/10.5
3.1/3.1
315/295/276
1100/1000/920
Auxiliary 2-way
0-12505-27603-3
2.7
640
UPC Code
FEATURES
AHRI & CEC
UL, CUL & CSA
1 Year Full/5 Year Sealed
Normal
Fresh or Recycled
Fin Coating
Air Intake
Low-Voltage Start-up
Auto Fan
Energy Saver
24 Hour On/Off Timer
Room Freeze Protection
Random Restart Protection
Quiet Start-up
Indoor Fan Speeds
LED Display
Yes
Yes
Yes
Yes
Yes
Yes
Yes
3
230/208V/60Hz
5.1/5.3
1120/1120
4.5/4.7
1010 / 990
13.2/12.2
3000/2452
20A
Volts/Hertz
Amps (Cool)
Watts (Cool)
Amps (Heat Pump)
Watts (Heat Pump)
Amps (Heat - Electric)
Watts (Heat - Electric)
Circuit Breaker
Yes
LCDI 6-20P
NEMA Plug Type
ACCESSORIES – A complete line of accessories is available for each Frigidaire PTAC model. For more details please contact our Commercial Call Center at 1-866-942-1567.
F11FRP12PTT2RSS
Download from Www.Somanuals.com. All Manuals Search And Download.
|