Frigidaire Air Conditioner FRP12PTT2R User Manual

Air Conditionerꢀ/ꢀ  
Heat Pumpꢀ/  
Backup Electric Heater  
PTAC  
FRP12PTT2R  
Product Dimensions  
Height  
Width  
Depth  
16"  
42"  
13-13/16"  
More Easy-To-Use Features  
Comfort Control Design  
Simple controls allow guests to  
customize their settings, while quiet,  
uniform air movement keeps rooms  
comfortable.  
Smart Self-Check  
Provides nine diagnostic points for self-  
check and correction of fault conditions.  
Eco-Friendly  
Frigidaire® uses R-410A refrigerant that’s  
not harmful to the earth’s ozone layer  
and meets U.S. Environmental Protection  
Agency requirements.  
Effortless™ Operation  
Simple, intuitive room controls are easy  
for guests to operate — ensuring a  
relaxing, more comfortable stay. Features  
like Effortless™ Restart and Ready-Select®  
controls reduce maintenance calls.  
Performance  
BTUs  
Cool  
12,000ꢀ/ꢀ11,800  
10,200ꢀ/ꢀ8,300  
10,700ꢀ/ꢀ10,500  
Backup Electric Heater  
Heat Pump  
Signature Features  
SilentDesign™  
Sound reduction package.  
Energy-Saver Option  
This function effortlessly maximizes  
energy efficiency while keeping guests  
comfortable.  
Effortless™ Maintenance  
Effortless™ Temperature  
Control  
Frigidaire® air conditioners maintain the  
preset room temperature so the room  
remains comfortable at all times and  
helps control energy levels.  
With Frigidaire’s reputation for durability,  
easy maintenance, availability of reliable  
parts and service you can count on,  
you can be sure that you’re getting the  
highest-quality performance.  
frigidaire.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PTAC  
FRP12PTT2R Air Conditionerꢀ/ꢀHeat Pumpꢀ/ꢀBackup Electric Heat  
Rearward Slope  
1/4" Slope  
Acccessory  
Outdoor Grille  
Front Panel  
Acccessory  
Wall Sleeve  
Outside Wall  
Inside Wall  
Chassis  
Product Dimensions  
Wall Cutout Dimensions  
Height  
16"  
Height  
Width  
16-5/16"  
42-3/16"  
Width  
42"  
Depth  
13-13/16"  
13-13/16"  
Max. Wall Thickness  
Plug Type (NEMA)  
6-20P  
PTAC Specifications  
Replacement Installation  
Product Shipping Weight (approx.) – 135 Lbs.  
When replacing existing PTAC with new unit, refer to Product  
Installation Guide on web to identify existing wall-sleeve manufacturer  
and size compatibility. If proper installation and slope are suspect,  
then correct installation of Frigidaire® PTAC Sleeve options  
recommended.  
For any sleeve retrofit application, be sure that the foam seals  
(factory-installed on the tube sheets) provide a good seal between  
the grille and the outdoor coil tube sheets. These foam seals provide  
a barrier that stops air from the inside mixing with air on the outside  
(known as air recirculation).  
Using Frigidaire® wall sleeve with Non-Frigidaire grille requires  
installation of an Accessory Baffle Kit, which ensures a good seal  
between the unit and exterior grille to prevent air recirculation. Air  
recirculation is a large contributor to performance loss and premature  
damage to major components.  
An electrical supply with grounded three-prong receptacle is  
required. The power supply circuit must be installed in accordance  
with current edition of National Electrical Code (ANSI/NFPA 70)  
and local codes & ordinances.  
Voltage Rating – 230Vꢀ/ꢀ208Vꢀ/ꢀ60 Hzꢀ/ꢀ20 Amps  
Amps @ 230/208V Volts = (Cool) 5.1ꢀ/ꢀ5.3 Ampsꢀ/ꢀ(Backup Electric  
Heater) 13.2ꢀ/ꢀ12.2 Ampsꢀ/ꢀ(Heat Pump) 4.5ꢀ/ꢀ4.7 Amps  
Always consult local and national electric codes.  
Recommended Circuit Breaker – 20 Amps  
Unit equipped with 230/208V 3-wire power supply cord, NEMA plug  
type 6-20P, approximately 66" long.  
In order for condensate water to drain properly inside the unit, the  
sleeve must be installed properly: Level from right to left with a slight  
1/4" rearward pitch from the indoor side to the outdoor side as shown  
in the illustration above. Refer to the Installation Instructions on the  
web.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.  
*See accessories pages attached for optional accessories.  
New Installation  
For new installation, Frigidaire® PTAC Sleeves are available and  
recommended for proper installation. See accessories pages for  
sleeve options.*  
PTAC installation requires 13-13/16" maximum wall thickness.  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-866-942-1567 frigidaire.com  
Specifications  
subject to change.  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-866-942-1567 frigidaire.ca  
FRP12PTT2R 06/11 © 2011 Electrolux Home Products, Inc.  
Printed in the U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Packaged Terminal Air Conditioner (PTAC)  
FRP12PTT2R – Cool & Heat Pump with Electric Heat Back-up, 12,000 BTU  
JOB:  
REFERENCE:  
APPROVAL:  
DATE:  
CONSTRUCTION:  
UNIT NUMBER:  
LOCATION:  
ENGINEER:  
SUBMITTED TO:  
DRAWING NUMBER:  
SUBMITTED BY:  
Dimensions  
Features  
24 Hour On/Off Timer  
Effortless™ Maintenance  
Effortless™ Protection  
Comfort Control Design  
Smart Self-Check  
Height: 16˝  
SilentDesign™  
Width: 42˝  
Depth: 13 13/16˝  
Energy-Saver Option  
Eco-Friendly with R410a Refrigerant  
Ready-Select® Controls with  
LED Temperature Display  
Unit Weight:  
111 Lbs.  
Shipping Weight: 135 Lbs.  
Effortless™ Temperature Control  
Versatile Multi-Mode Operation  
Effortless™ Operation  
Front desk Control Ready  
Cord included (LCDI 6-20P)  
Commercial Grade Warranty  
Max Wall Thickness: 13 13/16˝  
Cut-Out Height:  
Cut-Out Width:  
16 5/16˝  
42 3/16˝  
Multi-Speed Fan  
PERFORMANCE  
BTU (Cool)  
BTU (Heat Pump)  
BTU (Heat - Electric)  
EER (Cooling)  
COP (Heat Pump)  
Dehumidification (Pints/Hr.)  
Approximate Cooling Area (Sq. Ft.)  
Performance Certification  
Safety Certification  
Commercial Grade Warranty  
ELECTRICAL  
SPECIFICATIONS  
Refrigerant  
Charge (Oz.)  
Noise Level Indoors (High/Med/Low) (dB)  
Air Volume (CFM) (High/Med/Low)  
Motor RPM (High/Med/Low)  
Air Direction Control  
12,000/11,800  
R410A  
26.8  
53/52/51  
10700 / 10500  
10,200/8,300  
10.7/10.5  
3.1/3.1  
315/295/276  
1100/1000/920  
Auxiliary 2-way  
0-12505-27603-3  
2.7  
640  
UPC Code  
FEATURES  
AHRI & CEC  
UL, CUL & CSA  
1 Year Full/5 Year Sealed  
Normal  
Fresh or Recycled  
Fin Coating  
Air Intake  
Low-Voltage Start-up  
Auto Fan  
Energy Saver  
24 Hour On/Off Timer  
Room Freeze Protection  
Random Restart Protection  
Quiet Start-up  
Indoor Fan Speeds  
LED Display  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
3
230/208V/60Hz  
5.1/5.3  
1120/1120  
4.5/4.7  
1010 / 990  
13.2/12.2  
3000/2452  
20A  
Volts/Hertz  
Amps (Cool)  
Watts (Cool)  
Amps (Heat Pump)  
Watts (Heat Pump)  
Amps (Heat - Electric)  
Watts (Heat - Electric)  
Circuit Breaker  
Yes  
LCDI 6-20P  
NEMA Plug Type  
ACCESSORIES – A complete line of accessories is available for each Frigidaire PTAC model. For more details please contact our Commercial Call Center at 1-866-942-1567.  
F11FRP12PTT2RSS  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Earthquake Sound Car Speaker EQ8S8 User Manual
Eiki Projector ESL Series User Manual
Euro Pro Food Processor KP81E User Manual
Extron electronic Switch SW6 VGA A User Manual
Fujitsu Marine Sanitation System C300 User Manual
Fujitsu Portable Generator J Adapter Class Generator User Manual
Garmin GPS Receiver 1350T User Manual
GE Answering Machine 2 9876 User Manual
Gemini Musical Instrument PS 626USB User Manual
Gianni Industries Door DG 15LD User Manual