		 CLEARWAVE™ WATER CONDITIONER   
					MODEL CW-HD-2   
					The ClearWave™ is the most advanced hi-tech computerized anti-scale device available today. It   
					operates by using a programmed ‘chip’ to constantly cycle through and induce over 200 different electro-   
					magnetic low frequency wave pulses into the water. These wave pulses produce water with remarkable   
					anti-scale properties, without adding salts or chemicals, at an operating cost for electricity of   
					approximately $25.00 per year.   
					POWER SPECIFICATIONS: 18 VAC, 25 Watts, .22 Amps   
					HOW IT WORKS   
					Pure water contains nothing but H20. But water, as it comes out of the ground, is rich in a multitude of   
					minerals. Minerals such as calcium and magnesium are the main components of hard water, and the   
					cause of scale formation and other problems.   
					There are three basic methods used to control the problem of hardness and specifically scale   
					formation.   
					ION EXCHANGE:   
					One method is to remove the calcium and magnesium from the water through ion exchange (the   
					traditional water softener). This method requires the use of a resin filled tank with a high concentration of   
					salt ions. As the water flows through the resin tank the salt ions (typically sodium) are exchanged for the   
					calcium or magnesium ions. This lowers the concentration of the minerals that cause scale and therefore   
					inhibits scale formation.   
					CHEMICAL ADDITION:   
					A second method used to control hard water scale is the addition of chemicals (such as phosphates) to   
					the water. These materials chemically alter the scaling characteristics of the calcium or magnesium,   
					allowing the concentration of the minerals to stay the same while still reducing scale formation and its   
					affects.   
					Both of the above methods require the use of consumable materials to change the makeup of the water.   
					For these devices to function properly, the homeowner must continuously replenish the salts or chemicals   
					as well as perform periodic maintenance on the equipment. In addition to these inconveniences, the   
					chemicals and salts discharged into the effluent water present problems downstream to the municipal   
					water treatment facility and the environment. Many U.S. cities have been enacting and/or evaluating   
					environmental legislation to limit or reduce the levels of chemicals or salts that result from these types of   
					water treatment methods.   
					ELECTRIC POTENTIAL:   
					A third method used to treat the hard water problems associated with scale utilizes changes in electrical   
					potential in the water to produce the affects of chemical addition. The electric potential applied changes   
					the scaling characteristics of the calcium or magnesium without the removal of these ions or the addition   
					of chemicals.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				INSTALLATION   
					WHERE TO INSTALL THE CLEARWAVE™   
					1. For water supply applications, locate where the main water supply pipe enters the home or   
					building. Point of use applications such as dishwashers, ice makers, boilers, water heaters   
					etc., attach the ClearWave™ unit to the water supply line to that particular appliance. For   
					long system piping lengths or high level calcium water, mount a CW-HD-1 to point of use   
					appliances.   
					2. Find a suitable location to install the ClearWave™ on the water supply pipe before the   
					piping branches off to supply water throughout the building.   
					HOW TO INSTALL THE CLEARWAVE™   
					1. One set of mounting brackets are provided, for mounting the ClearWave™ onto 1-1/2 inch   
					to 4 inch water pipes or wall mounted near the selected pipe area. Mount the mounting   
					brackets to the base of the ClearWave™ by using the screws provided. Mount the   
					ClearWave™ onto the pipe with wire ties or to the wall with appropriate fasteners. (see   
					Figure 1) For pipe mounting, the wall mount tabs should be removed from the mounting   
					brackets. (see Figure 2)   
					2. Plug the antennas into each end of the housing, to the appropriate wire wrap connections   
					(e.g. “CW” for clockwise wrapping and “CCW” for counter clockwise wrapping). If longer   
					wires are needed, up to 50 feet of 12Ga stranded wire can be added to the antenna wires   
					with an insulated butt end wire connector or they can be replaced with 60 feet of 12Ga   
					stranded wire.   
					Figure 1   
					Page 3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Figure 1A   
					Figure 2   
					PROPERLY WRAPPING THE ANTENNAE   
					The antenna wrap around the water pipe on each end of the ClearWave™ (see Figure 1). A   
					minimum of seven fully wrapped coils of the antenna wire, with each coil wrapped tightly against   
					the pipe and pressed snugly against each other is required for best results (see Figure 1A).   
					Each wire coil should be spaced 1 inch to 2 inches apart. The operation of the ClearWave™   
					and the antenna installation is not based on direction of water flow, but one antenna MUST be   
					wrapped in a clockwise direction and the other wrapped in an counter-clockwise direction.   
					1. On the right side of the unit wrap the first antenna onto the water pipe by securing the “CW”   
					clockwise antenna to the water pipe next to the ClearWave™ housing with a wire tie. Wrap   
					the right antenna clockwise (over the top of the pipe first), keeping the antenna wire tight   
					against the pipe and the preceding coil. Secure the end of the antenna wire to the water   
					pipe with a wire tie (see Figure 1A). Repeat wrapping the remainder of the antennas onto   
					the pipe alternating the wrap direction (see Figure 1).   
					2. On left side of the unit wrap the first antenna onto the water pipe by securing the “CCW anti   
					clockwise antenna to the water pipe next to the ClearWave™ housing with a wire tie. Wrap   
					the antenna counter-clockwise (Under the bottom of the pipe first), keeping the antenna wire   
					tight against the pipe and the preceding coil. Secure the end of the antenna wire to the   
					water pipe with a wire tie. Repeat wrapping the remainder of the antennas onto the pipe   
					alternating the wrap direction (see Figure 1).   
					3. When energized, the ClearWave™ by plugging in the power supply, the modulation   
					indicator lights start flashing sequentially indicating that the ClearWave™ is functioning   
					properly. If the indicator lights do not flash sequentially, unplug the power supply, wait one   
					minute then plug in the power supply again. If at any time a functional problem is   
					suspected, unplug the power supply, wait one minute then plug in the power supply again.   
					NOTE: The performance of the ClearWave™ is not affected by the direction or orientation of the unit.   
					The unit may be mounted to horizontal, vertical, or diagonally. The ClearWave™ can be used effectively   
					on any type of water pipe; galvanized, copper, or plastic.   
					NOTE: The ClearWave™ is designed and tested to cause little or no interference to other   
					communication devices, such as televisions, and most cordless telephones. Install the ClearWave™ at   
					least ten feet from any radio, television, or cordless telephone base unit to eliminate possible interference.   
					MAXIMUM WATER CONDITIONING CAPACITY FOR NOMINAL PIPE DIAMETERS   
					Nominal Pipe Diameter   
					1 inch   
					1 
					69   
					2 inch   
					1 
					118   
					3 inch   
					1 
					219   
					4 inch   
					2 
					450   
					# of Units Req.   
					GPM Flow   
					Page 4   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				OPERATION TIMETABLE FOR THE CLEARWAVE™   
					The following timetable of events should be used to evaluate the operation of the ClearWave™ during the   
					180-day customer satisfaction period. This is the best way to evaluate the ClearWave™ operation and   
					benefits the ClearWave™ technology can provide for you and your home. Please note testing for   
					changes in hardness with current testing practices will not show you if the ClearWave™ is working. The   
					current practice of determining water hardness is the measurement of the concentration of calcium and   
					magnesium in the water. Since the ClearWave™ does not remove any calcium or magnesium ions from   
					the water, testing the water before and after the installation of the ClearWave™ will not show any change.   
					DAY 1:........................................The ClearWave™ action immediately starts to loosen existing scale in   
					both the hot and cold water systems. One should find soap lathers more easily.   
					DAY 5 and onwards: ..................Scale begins to break down and come off water heater elements   
					(immersion heaters) and tanks. Most particles are microscopic and will flow through your water system,   
					but some small particles may be seen in the water coming from the hot water tap.   
					DAY 10 to 16:.............................It should be noticeably easier to wipe clean ceramic, plastic, glass, and   
					metal surfaces. By now the quantity of bath soap, dish soap, laundry detergent, and laundry softening   
					agents can be reduced. Scale should have loosened on faucet, showerheads and frequently used   
					appliances that boil water (such as coffee makers).   
					DAY 16 and onwards: ................Scale should continue to loosen from faucet, showerheads, and pipes.   
					With the continuing break down and reduction of scale from the heating surfaces of water heaters, water   
					should heat up quicker using less energy to achieve the desired temperature.   
					After 1 to 2 months:....................Any scaly crust or stains in toilets or under faucet should be significantly   
					reduced. No new stains or crust should form. Mold that attaches to scale will begin to disappear from   
					shower curtains and once cleaned should not reappear. Depending on the water hardness in the area,   
					the full affects can take up to 12 weeks, especially if the system has been heavily scaled up over many   
					years.   
					NOTES:   
					1) If iron is present in the water supply, use an iron filter prior to the ClearWave™.   
					2) Depending on water hardness or water make-up, two CW-HD-2 units may be required.   
					3) The CW-HD-2 can be used on water up to 25 grains of hardness. If over 25 grains, it can be   
					used to aid the operation of a water softener.   
					MANUFACTURERS’ WARRANTY:   
					The ClearWave™ unit is guaranteed for 18 months from the date of the original purchase against defects   
					in workmanship and material. During that period these defects will be repaired or the unit will be replaced   
					without charge at manufacturers option. *This guarantee covers normal consumer usage but excludes   
					damage caused by alteration, accident, misuse, abuse, neglect, installation, or normal wear and tear.   
					Should your unit fail within the unit guarantee period, please pack it carefully in the original box and return   
					it to your supplier. This guarantee does not affect your statutory rights. Please return the guarantee at the   
					end of this manual, to register your purchase.   
					SATISFACTION GUARANTEED:   
					In the unlikely event you are not satisfied with the performance of the ClearWave™ Water Conditioner it   
					should be returned with the receipt to the point of purchase (complete), and within 180 days of the original   
					purchase date. It should be packed in the original, box and is subject to the: * Terms and Conditions of   
					the manufacturers’ warranty.   
					Page 5   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				For more information on the ClearWave™, visit the Field Controls web site at   
					
					P/N 46302500 Rev. A   
					Page 6   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ꢀ 
					Warranty Registration   
					ClearWave™   
					Name:_____________________________________________   
					Address: ___________________________________________   
					City: _____________ State: ____________ Zip Code: ______   
					Phone#: ________________ Fax# ______________________   
					1. Grains if Known.   
					2. ppm’s if Known.   
					Light   
					Moderate   
					Heavy   
					Very Heavy   
					3. Do you have iron present in   
					your water?   
					YES   
					NO   
					If Yes, circle one   
					ppm’s if Known   
					4. Had you installed an Iron filter   
					prior to purchasing the   
					ClearWave™?   
					YES   
					NO   
					5. Where did you purchase the   
					ClearWave™ from?   
					6. Date purchased.   
					7. Mfg. date code.   
					Hardness   
					Level Check   
					One   
					Briefly describe any current water   
					9 
					problems; scale build up, odor, taste,   
					staining, etc…____________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					_______________________________   
					Light:   
					1-3 grains   
					17-51 ppm   
					Moderate:   
					4-6 grains   
					52-102 ppm   
					Hard:   
					7-10 grains   
					103-170   
					ppm   
					Very Hard:   
					10 grains &   
					above   
					170 ppm &   
					above   
					_______________________________   
					(ppm-Parts Per Million)   
					Download from Www.Somanuals.com. All Manuals Search And Download.   