FMI Indoor Fireplace VCM 36Q User Manual

resIdeNTIAl ANd oUTdoor  
UNVeNTed (VeNT-Free) UNIVersAl FIreBoX  
oWNers oPerATIoN ANd INsTAllATIoN MANUAl  
PFS  
®
US  
Models (V)QM36(sr,sI,Hr,HI), VCM-36Q, (V)QM42(sr,sI,Hr,HI),  
VCM-42Q, (V)QM50(sr,sI,Hr,HI), VCM-50Q  
WARNING: If the information in this manual is not  
followed exactly, a fire or explosion may result causing  
property damage, personal injury or loss of life.  
— Do not store or use gasoline or other flammable  
vapors and liquids in the vicinity of this or any other  
appliance.  
— WHAT TO DO IF YOU SMELL GAS  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do not use any  
phone in your building.  
• Immediatelycallyourgassupplierfromaneighbor’s  
phone. Follow the gas supplier’s instructions.  
• If you cannot reach your gas supplier, call the fire  
department.  
— Installationandservicemustbeperformedbyaquali-  
fied installer, service agency or the gas supplier.  
INSTALLER: Leave this manual with the appliance.  
CONSUMER: Retain this manual for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
sAFeTy  
Continued  
You must operate this fireplace  
WARNING: Any change to  
this firebox or its controls can  
be dangerous.  
with the provided fireplace  
screen and hood in place.  
Make sure these parts are in  
place and screens are closed  
before running installed gas  
log heater. Replace hood with  
FMI pRODUcTS, LLc model  
109511-01 50", 109511-02 42",  
or109511-0336"only.Thishood  
has been designed to keep the  
operation of your fireplace safe  
and efficient.  
WARNING:Donotallowfans  
to blow directly into the firebox.  
Avoidanydraftsthatalterburner  
flame patterns. Ceiling fans can  
create drafts that alter burner  
flame patterns. Altered burner  
patterns can cause sooting.  
WARNING:Donotuseablow-  
er insert, heat exchanger insert  
orotheraccessorynotapproved  
for use with this firebox.  
1. Do not use this firebox as a wood burning  
fireplace. Use only decorative unvented  
room heaters (log sets).  
2. Donotaddextralogsorornamentssuchas  
pine cones, vermiculite or rock wool. Using  
these added items can cause sooting.  
Due to high temperatures, the  
applianceshouldbelocatedout  
oftrafficandawayfromfurniture  
and draperies.  
3. Use only the provided hood. See Parts,  
page 30.  
4. Vent-free gas log heaters installed in these  
fireboxes require fresh air ventilation to  
run properly. See Air for Combustion and  
Ventilation, page 8.  
5. Do not run vent-free heaters installed in  
these fireboxes  
Do not place clothing or other  
flammable material on or near  
the appliance. Never place any  
objects in the firebox or on  
logs.  
• where flammable liquids or vapors are  
used or stored  
• under dusty conditions  
6. Do not use this firebox to cook food or  
burn paper or other objects.  
7. Turn unit off and let cool before servicing.  
Only a qualified service person should  
service and repair firebox.  
8. Operating vent-free heaters installed in  
these fireboxes above elevations of 4,500  
feet could cause pilot outage.  
9. Do not use the firebox if it has been  
under water.  
Firebox front and screen be-  
comes very hot when running  
firebox.Keepchildrenandadults  
away from hot surfaces to avoid  
burns or clothing ignition. Fire-  
box will remain hot for a time  
after shutdown. Allow surfaces  
to cool before touching.  
10. Before using furniture polish, wax, carpet  
cleaner or similar products, turn heater  
off. If heated, the vapors from these prod-  
ucts may create a white powder residue  
within burner box or on adjacent walls  
and furniture.  
Carefully supervise young chil-  
dren when they are in the room  
with firebox.  
Keepthereplaceareaclearand  
freefromcombustiblematerials,  
gasoline, and other flammable  
vapors and liquids.  
11. Provide adequate clearances around air  
openings.  
122275-01G  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
loCAl Codes  
Install and use firebox with care. Follow all  
State of Massachusetts: The installation  
must be made by a licensed plumber  
or gas fitter in the Commonwealth of  
Massachusetts.  
local codes. In the absence of local codes,  
use the latest edition of The National Fuel Gas  
Code ANSI Z223.1/NFPA 54*. Firebox must  
be electrically grounded in accordance with  
the National Electrical Code, ANSI/NFPA70  
(latest edition).  
*Available from:  
American National Standards Institute, Inc.  
1430 Broadway  
Sellers of unvented propane or natural  
gas-fired supplemental room heaters  
shall provide to each purchaser a copy of  
527 CMR 30 upon sale of the unit.  
Vent-free gas products are prohibited for  
bedroom and bathroom installation in  
the Commonwealth of Massachusetts.  
New York, NY 10018  
National Fire Protection Association, Inc.  
Batterymarch Park  
Quincy, MA 02269  
loCATINg FIreBoX  
pLANNING  
ProdUCT FeATUres  
OpERATION  
Plan where you will install the firebox. This will  
save time and money later when you install  
the firebox. Before installation, consider the  
following:  
This firebox is designed for use with approved  
ANSI Z21.11.2 decorative type unvented room  
heaters. (Physical size limitations apply. Refer  
to minimum firebox requirements supplied  
with log heater.) It requires no outside vent-  
ing or chimney making installation easy and  
inexpensive.  
1. Where firebox will be located. Allow for  
wall and ceiling clearances (see Installa-  
tion Clearances, page 11).  
2. Everything needed to complete installation.  
3. These models CANNOT be installed in  
a bedroom unless maximum Btu rating  
of installed vent-free log set is less than  
10,000 Btu/hr.  
4. Proper air for combustion and ventilation  
(page 8).  
4
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProdUCT sPeCIFICATIoNs  
36" MODELS (V)qM36 SERIES AND VCM-36q  
29"  
22"  
18 3/8  
"
19 13/16"  
(Ref.)  
30 1/2  
"
4 7/8  
"
34 3/4  
"
1 5/16"  
3 3/4  
"
36" HEARTH  
11 1/8  
"
54 1/2  
"
50"  
365/16"  
30"  
97/16"  
35/16"  
7"  
7 7/8  
"
7 3/8  
"
36"  
45 1/8  
111/8  
"
"
Figure 1 - 36" Models (V)QM36 Series and VCM-36Q  
122275-01G  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProdUCT sPeCIFICATIoNs  
Continued  
42" MODELS (V)qM42 SERIES AND VCM-42q  
30 5/16  
"
25"  
22 1/2"  
23 13  
/
"
16  
32 3/8"  
(Ref.)  
4 7/8"  
40 3/4"  
3 3/4"  
1 5/16  
"
42" HEARTH  
11 1 /8"  
54 1/2"  
50"  
30"  
36 5/16  
"
9 7/16  
3 5/16  
"
7 7/8"  
7"  
"
42"  
51 1/8"  
8 3/4"  
13"  
Figure 2 - 42" Models (V)QM42 Series and VCM-42Q  
6
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProdUCT sPeCIFICATIoNs  
Continued  
50" MODELS (V)qM50 SERIES AND VCM-50q  
38 5  
/
16  
"
33"  
22 1/2"  
23 13  
/
16  
"
32 3/8"  
(Ref.)  
4 7/8"  
40 3/4"  
3 3/4"  
1 5  
/
16  
"
50" HEARTH  
11 1/8"  
54 1/2"  
30"  
50"  
"
365/16  
97/16  
"
7 7/8"  
7"  
35/16  
"
50"  
59 1/8"  
8 3/4"  
13"  
Figure 3 - 50" Models (V)QM50 Series and VCM-50Q  
122275-01G  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIr For CoMBUsTIoN ANd VeNTIlATIoN  
Unusually tight construction is defined as  
construction where:  
WARNING: This heater shall  
notbeinstalledinaroomorspace  
unlesstherequiredvolumeofin-  
door combustion air is provided  
by the method described in the  
National Fuel Gas Code, ANSI  
Z223.1/NFPA54,theInternational  
Fuel Gas Code, or applicable lo-  
cal codes. Read the following in-  
structionstoinsureproperfresh  
airforthisandotherfuel-burning  
appliances in your home.  
a. walls and ceilings exposed to the out-  
side atmosphere have a continuous  
water vapor retarder with a rating of  
one perm (6 x 10-11 kg per pa-sec-m2) or  
less with openings gasketed or sealed  
and  
b. weather stripping has been added on  
openable windows and doors and  
c. caulking or sealants are applied to  
areas such as joints around window  
and door frames, between sole plates  
and floors, between wall-ceiling joints,  
between wall panels, at penetrations  
for plumbing, electrical and gas lines  
and at other openings.  
Today’s homes are built more energy efficient  
than ever. New materials, increased insulation  
and new construction methods help reduce  
heat loss in homes. Home owners weather  
strip and caulk around windows and doors to  
keep the cold air out and the warm air in. Dur-  
ing heating months, home owners want their  
homes as airtight as possible.  
If your home meets all of the three criteria  
above, you must provide additional fresh  
air. See Ventilation Air From Outdoors,  
page 10.  
If your home does not meet all of the three  
criteria above, proceed to Determining  
Fresh-Air Flow For Firebox Location.  
While it is good to make your home energy  
efficient, your home needs to breathe. Fresh  
air must enter your home. All fuel-burning ap-  
pliances need fresh air for proper combustion  
and ventilation.  
Confined and Unconfined Space  
The National Fuel Gas Code, ANSI Z223.1/  
NFPA54 defines a confined space as a space  
whose volume is less than 50 cubic feet per  
1,000 Btu per hour (4.8 m3 per kw) of the ag-  
gregate input rating of all appliances installed  
in that space and an unconfined space as a  
space whose volume is not less than 50 cubic  
feet per 1,000 Btu per hour (4.8 m3 per kw)  
of the aggregate input rating of all appliances  
installed in that space. Rooms communicating  
directly with the space in which the appliances  
are installed*, through openings not furnished  
with doors, are considered a part of the un-  
confined space.  
Exhaust fans, fireplaces, clothes dryers and  
fuelburningappliancesdrawairfromthehouse  
to operate. You must provide adequate fresh  
air for these appliances. This will insure proper  
venting of vented fuel-burning appliances.  
pROvIDING ADEQUATE  
vENTILATION  
The following are excerpts from National Fuel  
Gas Code, ANSI Z223.1/NFPA 54, Air for  
Combustion and Ventilation.  
All spaces in homes fall into one of the three  
following ventilation classifications:  
* Adjoining rooms are communicating only if  
there are doorless passageways or ventilation  
grills between them.  
1. Unusually Tight Construction  
2. Unconfined Space  
DETERMINING FRESH-AIR FLOW  
FOR FIREbOx LOcATION  
Determining if You have a Confined or  
Unconfined Space  
Use this work sheet to determine if you have  
a confined or unconfined space.  
3. Confined Space  
Theinformationonpages8 through 10 willhelp  
you classify your space and provide adequate  
ventilation.  
Unusually Tight Construction  
The air that leaks around doors and windows  
may provide enough fresh air for combustion  
and ventilation. However, in buildings of un-  
usually tight construction, you must provide  
additional fresh air.  
Space: Includes the room in which you will  
install heater plus any adjoining rooms with  
doorless passageways or ventilation grills  
between the rooms.  
8
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIr For CoMBUsTIoN ANd VeNTIlATIoN  
Continued  
1. Determine the volume of the space (length  
If the actual Btu/Hr used is less than the  
maximum Btu/Hr the space can support, the  
space is an unconfined space. You will need  
no additional fresh air ventilation.  
x width x height).  
Length x Width x Height =__________cu. ft.  
(volume of space)  
Example: Space size 22 ft. (length) x 18 ft.  
(width) x 8 ft. (ceiling height) = 3,168 cu. ft.  
(volume of space)  
If additional ventilation to adjoining room  
is supplied with grills or openings, add the  
volume of these rooms to the total volume  
of the space.  
WARNING:Iftheareainwhich  
theheatermaybeoperateddoes  
notmeettherequiredvolumefor  
indoorcombustionair,combus-  
tion and ventilation air shall be  
provided by one of the methods  
described in the National Fuel  
GasCode,ANSIZ223.1/NFPA54,  
theInternationalFuelGasCode,  
or applicable local codes.  
2. Multiply the space volume by 20 to determine  
the maximum Btu/Hr the space can support.  
________ (volume of space) x 20 = (Maxi-  
mum Btu/Hr the space can support)  
Example: 3,168 cu. ft. (volume of space) x 20 =  
63,360 (maximum Btu/Hr space can support)  
3. Add the Btu/Hr of all fuel burning appliances  
in the space.  
Vent-free fireplace  
Gas water heater*  
Gas furnace  
Vented gas heater  
Gas fireplace logs  
Other gas appliances* + _________ Btu/Hr  
Total = _________Btu/Hr  
* Do not include direct-vent gas appliances.  
Direct-vent draws combustion air from the  
outdoors and vents to the outdoors.  
Example:  
Gas water heater  
39,000  
Vent-free fireplace + _________Btu/Hr  
Total  
_________Btu/Hr  
_________Btu/Hr  
_________Btu/Hr  
_________Btu/Hr  
_________Btu/Hr  
vENTILATION AIR  
Ventilation Air From Inside Building  
This fresh air would come from an adjoining  
unconfined space. When ventilating to an  
adjoining unconfined space, you must provide  
two permanent openings: one within 12" of the  
ceiling and one within 12" of the floor on the  
wall connecting the two spaces (see options  
1 and 2, Figure 4). You can also remove door  
into adjoining room (see option 3, Figure 4).  
Follow the National Fuel Gas Code, ANSI  
Z223.1/NFPA 54, Air for Combustion and  
Ventilation for required size of ventilation  
grills or ducts.  
40,000  
_________Btu/Hr  
79,000  
= _________Btu/Hr  
4. Compare the maximum Btu/Hr the space  
can support with the actual amount of Btu/Hr  
used.  
12"  
_______ Btu/Hr (maximum the space can  
support)  
_______ Btu/Hr (actual amount of Btu/Hr  
used)  
Ventilation  
Ventilation Grills  
Into Adjoining Room,  
Option 2  
Grills Into  
Adjoining  
Room,  
Or  
Remove  
Door into  
Adjoining  
Room,  
Option  
3
Option 1  
Example: 63,360 Btu/Hr (maximum the  
space can support)  
79,000 Btu/Hr (actual amount of  
Btu/Hr used)  
The space in the example is a confined space  
because the actual Btu/Hr used is more than the  
maximum Btu/Hr the space can support. You  
must provide additional fresh air. Your options  
are as follows:  
12"  
A. Rework worksheet, adding the space of an  
adjoining room. If the extra space provides an  
unconfined space, remove door to adjoining  
room or add ventilation grills between rooms.  
See Ventilation Air From Inside Building.  
Figure 4 - Ventilation Air from Inside  
Building  
B. Vent room directly to the outdoors. See  
Ventilation Air From Outdoors, page 10.  
C. Install a lower Btu/Hr fireplace, if lower Btu/  
Hr size makes room unconfined.  
122275-01G  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIr For CoMBUsTIoN ANd VeNTIlATIoN  
Continued  
ventilation Air From Outdoors  
Provide extra fresh air by using ventilation  
grills or ducts. You must provide two perma-  
nent openings: one within 12" of the ceiling  
and one within 12" of the floor. Connect these  
items directly to the outdoors or spaces open  
to the outdoors. These spaces include attics  
and crawl spaces. Follow the National Fuel  
Gas Code, ANSI Z223.1/NFPA 54, Air for  
Combustion and Ventilation for required size  
of ventilation grills or ducts.  
Ve ntilated  
Attic  
Outlet  
Air  
Outlet  
Air  
T o Attic  
T o  
Crawl  
Space  
Inlet  
Air  
Ve ntilated  
Crawl Space  
Inlet Air  
IMPORTANT: Do not provide openings for  
inlet or outlet air into attic if attic has a thermo-  
stat-controlled power vent. Heated air entering  
the attic will activate the power vent.  
Figure 5 - Ventilation Air from Outdoors  
INsTAllATIoN  
NOTICE: The firebox identifica-  
tionlabel(includingmodelnum-  
ber, serial number, clearances,  
etc.) is located on a chain under  
the bottom refractory.  
WARNING: A qualified ser-  
vicepersonmustinstallrebox.  
Follow all local codes.  
WARNING: Never install  
firebox  
IMPORTANT: Vent-free gas log heaters add  
moisture to the air. Although this is beneficial,  
installing firebox in rooms without enough  
ventilation air may cause mildew to form from  
too much moisture. See, page 8.  
• in a bedroom or bathroom*  
• in a recreational vehicle  
• where curtains, furniture,  
clothing, or other flammable  
objectsarelessthan36"from  
front or 42" from top of fire-  
box. For side clearances see  
Figure 6, page 11  
IMPORTANT: Make sure the firebox is level.  
If firebox is not level, log set will not work  
properly.  
Note: Your firebox is designed to be used in  
zero clearance installations. Wall or framing  
material can be placed against any exterior  
surface on the rear, sides, top or bottom of  
your firebox, except where standoff spacers  
are integrally attached. If standoff spacers are  
attached to your firebox, these spacers can  
be placed directly against wall or framing ma-  
terials. Use the dimensions shown for rough  
opening to create the easiest installation.  
• in high traffic areas  
• in windy or drafty areas  
*Unlessinstalledlogsetisrated  
at 10,000 Btu/hr or less.  
CAUTION: Log heaters  
installed in this firebox create  
warmaircurrents.Thesecurrents  
move heat to wall surfaces next  
to firebox. Installing firebox next  
tovinylorclothwallcoveringsor  
operating firebox where impuri-  
ties(suchas,butnotlimitedto,to-  
bacco smoke, aromatic candles,  
cleaning fluids, oil or kerosene  
lamps, etc.) in the air exist, may  
discolor walls or cause odors.  
Use dimensions shown for rough openings  
to create the easiest installation (see Built-In  
Firebox Installation, page 12).  
10  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
Mantel clearances for built-In  
Installation  
INSTALLATION cLEARANcES  
If placing custom mantel above built-in fire-  
box, you must meet the minimum allowable  
clearance between mantel shelf and top of  
firebox opening shown in Figure 7. These are  
the minimum allowable mantel clearances  
for a safe installation. Use larger clearances  
wherever possible to minimize the heating of  
objects and materials placed on the mantel.  
WARNING: Maintain the  
minimum clearances. If you  
can, provide greater clearances  
from floor, ceiling, and adjoin-  
ing wall.  
Carefully follow the instructions below. This  
will ensure safe installation.  
Minimum Wall and Ceiling Clearances  
(see Figure 6)  
A. Clearances from the side of the fireplace  
cabinet to any combustible material and  
wall should follow diagram in Figure 6.  
cAUTION: Do not allow the  
vent-freegaslogheatertotouch  
or extend beyond the fireplace  
screen.  
Example: The face of a mantel, bookshelf,  
NOTICE: Surface temperatures  
of adjacent walls and mantels  
become hot during operation.  
Walls and mantels above the  
firebox may become hot to  
the touch. If installed properly,  
these temperatures meet the  
requirement of the national  
product standard. Follow all  
minimum clearances shown in  
this manual.  
etc. is made of combustible material and  
1
protrudes 3 /2" from the wall. This com-  
bustible material must be 4" from the side  
of the fireplace cabinet (see Figure 6).  
B. Clearances from the top of the firebox  
opening to the ceiling should not be less  
than 42".  
C. When the firebox is installed directly on  
carpeting, tile or other combustible mate-  
rial, other than wood flooring, the firebox  
should be installed on a metal or wood  
panel extending the full width and depth  
of the enclosure.  
Wall board or facing  
Mantel Shelf  
D. Clearances from the bottom of firebox to  
the floor is 0".  
material (above  
Note: Any portion of the  
firebox) may be of  
mantel shelf must NOT  
extend beyond this profile.  
combustible material,  
including decorative  
12"  
These fireboxes can be installed as free-  
standing units against a wall with approved  
cabinet mantels that may be available from  
your retailer or supplier, or as a built-in unit.  
The clearances are the same for either instal-  
lation method.  
mantel ornaments or  
6 3  
1 1  
/4"  
other similar projec-  
tions off of the facing  
material.  
/
2"  
Framing  
Material  
Noncombustible  
Material May  
12" 16" 20"  
Project Off this  
Surface above  
the Firebox Hood  
Firebox  
Note: All vertical  
Example  
measurements are  
from top of fireplace  
hood opening to  
bottom of mantel shelf.  
These minimum  
Wire-mesh  
Screen  
Supplied  
Firebox Hood  
Must Be Used  
at All Times  
clearances replace any  
other recommended  
clearances supplied  
with your ANSI Z21.11.2  
approved gas logs.  
*
Figure 7 - Minimum Mantel Clearances  
for Built-In Installation  
*Minimum 16" from Side Wall  
Figure 6 - Minimum Clearance for  
Combustible to Wall  
122275-01G  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
3. Carefully set firebox in front of rough  
NOTIcE:Ifyourinstallationdoes  
not meet the minimum clear-  
ances shown, you must do one  
of the following:  
• raise the mantel to an accept-  
able height  
opening with back of firebox inside wall  
opening.  
4. Carefully insert firebox into rough opening.  
5. Attach firebox to wall studs using nails  
or wood screws through holes in nailing  
flange (see Figure 10).  
6. Install and properly test gas log heater.  
Follow installation instructions included  
with the vent-free gas log heater that is  
being installed.  
• remove the mantel  
bUILT-IN FIREbOx INSTALLATION  
Built-in installation of this firebox involves  
installing firebox into a framed-in enclosure.  
This makes the front of firebox flush with wall.  
If installing a mantel above the firebox, you  
must follow the clearances shown in Figure  
7, page 11. Follow these instructions to install  
the firebox in this manner.  
IMPORTANT: When finishing your firebox,  
combustible materials such as wall board,  
gypsum board, sheet rock, drywall, plywood,  
etc. may be butted up next to the sides and top  
of the firebox. Combustible materials should  
never overlap the firebox front facing.  
1. Frame in rough opening. The firebox fram-  
ing should be constructed of 2 x 4 lumber  
or heavier. Use dimensions and rough  
opening layout in Figure 8. Adjust framing  
so that firebox flushes with finished wall  
surface. If installing in a corner, use dimen-  
sions in Figure 9, for rough opening.  
2. Install gas piping to firebox location. See  
Installing Gas Line on page 14 and Con-  
necting to Gas Supply in log set owner’s  
manual.  
WARNING: Do not allow any  
combustiblematerialstooverlap  
the firebox front facing.  
IMPORTANT: Noncombustible materials such  
as brick, tile, etc. may overlap the front fac-  
ing, but should never cover any necessary  
openings.  
WARNING:Donotallownon-  
combustible materials to cover  
any necessary openings.  
54.625"  
Nails or  
Wood  
Screws  
30.125"  
28.250"  
(36" Models)  
45.375" (36" Models)  
51.375" (42" Models)  
59.375" (50" Models)  
Figure 8 - Framing Dimensions  
Maintain 1 1/2"  
Clearance at Sides  
and Back of Fireplace  
61" (36" Models)  
65" (42" Models)  
71" (50" Models)  
1 1/2" Clearance  
Not Required at  
Nailing Flanges  
Nailing  
Flanges  
Figure 10 - Attaching Firebox to Wall  
Studs  
86.5" (36" Models)  
92" (42" Models)  
100" (50" Models)  
Figure 9 - Corner Installation  
12  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
WARNING: Use only non-  
combustible mortar or adhe-  
siveswhenoverlappingthefront  
facing with noncombustible  
facing material.  
Cabinet  
Mantel  
Gas Line  
INSTALLING FIREbOx USING  
OpTIONAL MANTELS AvAILAbLE  
FROM RETAILER OR cUSTOM bUILT  
Access Hole  
(Either Side  
of Firebox)  
Gas  
Piping  
WARNING: A qualified ser-  
vicepersonmustinstallrebox.  
Follow all local codes.  
Figure 11 - Installing Cabinet Mantel  
(Mantel May Vary From Illustration)  
This firebox may be installed using a cabinet  
mantel against a wall in your home. The  
firebox and cabinet mantel can be installed  
directly on the floor. Mantels may be avail-  
able from your retailer or custom built for  
your home.  
1. Assemble cabinet mantel as instructed.  
2. Install gas piping to firebox location. See  
Installing Gas Line, page 14.Youmayhave  
to cut an access hole in the floor or wall to  
run gas line to firebox. Make sure to locate  
access hole so cabinet mantel will cover it  
when installed (see Figure 11).  
3. Place firebox on floor in desired location.  
Make sure mantel will be flush against  
wall when installed.  
4. Carefully slide cabinet mantel over firebox.  
Be careful not to scratch firebox, cabinet  
mantel, flooring, etc., when installing (see  
Figure 12).  
5. Install and properly test gas log heater.  
Follow installation instructions included  
with the vent-free gas log heater that is  
being installed.  
Figure 12 - Inserting Firebox Into  
Cabinet Mantel (Mantel May Vary From  
Illustration)  
122275-01G  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
2. Install right side as left side in step 1 using  
INSTALLING GAS LINE  
screws provided.  
WARNING: A qualified ser-  
vicepersonmustconnectheater  
to gas supply. Follow all local  
codes.  
3. Install back panel and secure back to  
sides and bottom of firebox with screws  
provided.  
4. Using self-tapping screws and a drill, place  
screws into large holes in back and side  
panels (see Parts, page 30), through wire  
mesh and into firebox wrapper to secure.  
IMPORTANT: See Connecting to Gas Supply  
in your log set owner’s manual for details on  
gas hookup.  
Hole in  
Side Panel  
You may run the gas line from either side of  
the firebox (see Figure 13). Decide which side  
you want to run the gas line from.  
Note: This is one option for installing shutoff  
valve. Check local codes for equipment shut-  
off valve location requirements.  
Figure 14 - Hole in Side Panel to Attach  
to Firebox Wrapper  
BRICK INSTALLATION  
Each brick housing is stamped with a number  
(full size bricks are not stamped). These num-  
bers will help identify bricks when installing. It  
is important to install these bricks exactly as  
instructed. Press brick firmly into brick housing  
until it snaps. Groove line on side of brick will  
come in contact with flange on brick housing.  
This secures brick into housing (see Figure  
15). Smaller bricks may require a small portion  
of furnace cement applied to back of brick to  
secure it until grouting has been completed.  
Equipment  
Shutoff Valves  
(Install One)  
Gas Line Hole  
Bricks are packaged in separate boxes. Brick  
matrixes on pages 15 through 27 show how  
bricks are packaged and placed for each  
size fireplace and the number of bricks per  
box. There are 2 extra full bricks included in  
hearth brick package.  
Figure 13 - Installing Gas Line and  
Equipment Shutoff Valve (Model May  
Vary From Illustration)  
BRICK PANEL INSTALLATION  
Install bricks one section at a time starting with  
hearth panel followed by rear panel, left panel  
and right panel. It is important to install bricks  
in sequence. Please note, full size bricks are  
NOT stamped.  
IMPORTANT:Installationofbrick  
should be done after the fire-  
place is placed in a permanent  
location.  
The brick housings are already installed on  
the panels. When installing brick housing  
panels into fireplace, wear gloves as edges  
may be sharp.  
1. Beginning with left side panel, place  
panel, bottom edge first, at an angle into  
fireplace. Secure to bottom of fireplace  
with screws provided.  
Figure 15 - Installing Bricks into Brick  
Housings  
14  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
hEARTh BRICK MATRIx  
RED  
FULL  
IvORY  
FULL  
QTY  
11*  
FULL  
FULL  
FULL  
FULL  
F124  
F124  
(112140-01) (112140-05)  
ASH BRICK ASH BRICK  
(120848-01) (120848-03)  
F012R  
F124R  
F125R  
1
FULL  
F126  
FULL  
FULL  
F126  
F012W  
F124W  
F125W  
2
2
2
120848  
Ash Brick  
FULL  
FULL  
F125  
F128  
F125  
F128  
F126R  
F128R  
* Includes 2 extra bricks.  
F126W  
F128W  
2
2
F012  
F012  
36" Hearth  
RED  
IvORY  
QTY  
FULL  
FULL  
13*  
F133  
F011  
F133  
(112140-01) (112140-05)  
ASH BRICK ASH BRICK  
(120848-01) (120848-03)  
1
F123  
FULL  
FULL  
F123  
F011R  
F059R  
F123R  
F124R  
F126R  
F132R  
F133R  
F011W  
F059W  
F123W  
F124W  
F126W  
F132W  
F133W  
1
4
2
2
2
2
2
FULL  
FULL  
FULL  
FULL  
FULL  
F124  
F124  
FULL  
FULL  
FULL  
FULL  
120848  
F126  
F126  
Ash Brick  
F132  
F059  
F059  
F059  
F059  
F132  
42" Hearth  
* Includes 2 extra bricks.  
RED  
IvORY  
QTY  
FULL  
FULL  
17*  
F011  
FULL  
FULL  
F011  
F011  
F135  
FULL  
F126  
F135  
(112140-01) (112140-05)  
ASH BRICK ASH BRICK  
(120848-01) (120848-03)  
FULL  
FULL  
FULL  
F126  
FULL  
FULL  
1
F024  
F024  
FULL  
FULL  
FULL  
F011R  
F011R  
F021R  
F024R  
F025R  
F059R  
F126R  
F134R  
F135R  
F011W  
F012W  
F021W  
F024W  
F025W  
F059W  
F126W  
F134W  
F135W  
3
2
2
2
2
2
2
2
2
FULL  
FULL  
F021  
FULL  
F021  
FULL  
120848  
Ash Brick  
F025  
F025  
F134  
F059  
F012  
F012  
F059  
F134  
50" Hearth  
* Includes 2 extra bricks.  
122275-01G  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
36" FULL STACKED BRICK MATRIx  
F147  
F148  
F148  
F036  
LEFT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
F158  
F158  
F158  
FULL  
FULL  
7
(112140-01) (112140-05)  
FULL  
FULL  
FULL  
F036R  
F143R  
F144R  
F147R  
F148R  
F158R  
F185R  
F191R  
F192R  
F036W  
F143W  
F144W  
F147W  
F148W  
F158W  
F185W  
F191W  
F192W  
3
2
1
1
2
3
1
1
1
F036  
FULL  
FULL  
FULL  
F036  
F185 or  
F191  
F192  
F150  
F150  
F160  
F148  
REAR REFRAcTORY  
FULL  
FULL  
FULL  
RED  
IvORY  
QTY  
FULL  
FULL  
8
F160  
F160  
FULL  
FULL  
(112140-01) (112140-05)  
F148R  
F150R  
F152R  
F153R  
F159R  
F160R  
F148W  
F150W  
F152W  
F153W  
F159W  
F160W  
1
2
1
2
6
4
FULL  
FULL  
F160  
FULL  
F153  
F152  
F153  
F147  
F148  
F148  
RIGHT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
F158  
F036  
FULL  
FULL  
7
(112140-01) (112140-05)  
FULL  
FULL  
FULL  
F036R  
F143R  
F144R  
F147R  
F148R  
F158R  
F185R  
F191R  
F192R  
F036W  
F143W  
F144W  
F147W  
F148W  
F158W  
F185W  
F195W  
F192W  
3
2
1
1
2
3
1
1
1
F158  
F158  
FULL  
FULL  
F036  
FULL  
F036  
F185 or  
F191  
F192  
16  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
42" FULL STACKED BRICK MATRIx  
LEFT REFRAcTORY  
F156  
F158  
F155  
F017  
FULL  
RED  
IvORY  
QTY  
FULL  
FULL  
FULL  
FULL  
F033  
FULL  
FULL  
8
(112140-01) (112140-05)  
F032  
F017R  
F032R  
F033R  
F143R  
F151R  
F155R  
F156R  
F158R  
F186R  
F190R  
F017W  
F032W  
F033W  
F143W  
F151W  
F155W  
F156W  
F158W  
F186W  
F190W  
1
3
3
3
1
1
1
2
1
1
F033  
F032  
FULL  
F158  
F151  
F033  
FULL  
FULL  
F190 or F186  
F032  
F157  
F033  
F017  
F017  
F157  
F033  
F032  
F032  
F032  
F032  
F032  
F032  
FULL  
FULL  
REAR REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
FULL  
FULL  
FULL  
7
(112140-01) (112140-05)  
F017R  
F032R  
F033R  
F152R  
F154R  
F157R  
F017W  
F032W  
F033W  
F152W  
F154W  
F157W  
2
6
4
2
2
2
F033  
F154  
F033  
F154  
FULL  
FULL  
F152  
FULL  
F152  
F017  
FULL  
F155  
F156  
F158  
RIGHT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
FULL  
FULL  
FULL  
F033  
FULL  
FULL  
8
(112140-01) (112140-05)  
F032  
F017R  
F032R  
F033R  
F143R  
F151R  
F155R  
F156R  
F158R  
F186R  
F190R  
F017W  
F032W  
F033W  
F143W  
F151W  
F155W  
F156W  
F158W  
F186W  
F190W  
1
3
3
3
1
1
1
2
1
1
F033  
FULL  
F032  
F158  
F151  
FULL  
FULL  
F033  
F190 or F186  
F032  
122275-01G  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
50" FULL STACKED BRICK MATRIx  
LEFT REFRAcTORY  
F147  
RED  
IvORY  
QTY  
F149  
F032  
F148  
FULL  
F148  
FULL  
FULL  
FULL  
7
FULL  
FULL  
FULL  
F158  
(112140-01) (112140-05)  
F032R  
F033R  
F143R  
F144R  
F145R  
F146R  
F147R  
F148R  
F149R  
F158R  
F191R  
F192R  
F032W  
F033W  
F143W  
F144W  
F145W  
F146W  
F147W  
F148W  
F149W  
F158W  
F191W  
F191W  
3
3
2
1
1
1
1
2
1
3
1
1
F033  
F032  
F158  
F158  
FULL  
FULL  
F033  
F032  
F145 or  
F191  
F146 or  
F192  
F033  
F150  
F148  
FULL  
F148  
F150  
F160  
REAR REFRAcTORY  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
RED  
IvORY  
QTY  
FULL  
FULL  
13  
FULL  
F160  
(112140-01) (112140-05)  
F148R  
F150R  
F152R  
F153R  
F159R  
F160R  
F148W  
F150W  
F152W  
F153W  
F159W  
F160W  
2
2
2
2
6
4
FULL  
FULL  
FULL  
F152  
FULL  
F152  
F160  
F153  
F160  
F153  
RIGHT REFRAcTORY  
F147  
RED  
IvORY  
QTY  
F148  
FULL  
F148  
FULL  
F149  
F032  
FULL  
FULL  
7
FULL  
FULL  
FULL  
F158  
F158  
F158  
(112140-01) (112140-05)  
F032R  
F033R  
F143R  
F144R  
F145R  
F146R  
F147R  
F148R  
F149R  
F158R  
F191R  
F192R  
F032W  
F033W  
F143W  
F144W  
F145W  
F146W  
F147W  
F148W  
F149W  
F158W  
F191W  
F192W  
3
3
2
1
1
1
1
2
1
3
1
1
F033  
F032  
FULL  
FULL  
F033  
F032  
F145 or  
F191  
F146 or  
F192  
F033  
18  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
36" FULL hERRINGBONE BRICK MATRIx  
F074  
F074  
LEFT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
(112140-01)  
FULL  
(112140-05)  
6
F068R  
F071R  
F072R  
F074R  
F113R  
F115R  
F165R  
F181R  
F189R  
S011R  
F068W  
F071W  
F072W  
F074W  
F113W  
F115W  
F165W  
F181W  
F189W  
S011W  
1
1
5
2
3
1
1
1
1
1
F181 or F071  
S011  
F074  
F074  
F117  
REAR REFRAcTORY  
F074  
F074  
F074  
RED  
FULL  
(112140-01)  
IvORY  
FULL  
(112140-05)  
QTY  
6
F068R  
F072R  
F074R  
F084R  
F107R  
F108R  
F117R  
F161R  
F168R  
F179R  
F187R  
F068W  
F072W  
F074W  
F084W  
F107W  
F108W  
F117W  
F161W  
F168W  
F179W  
F187W  
1
1
6
3
3
1
1
1
2
1
1
F074  
F187  
F074  
RIGHT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
(112140-01)  
FULL  
(112140-05)  
3
F122  
F068R  
F071R  
F072R  
F074R  
F110R  
F112R  
F068W  
F071W  
F072W  
F074W  
F110W  
F112W  
4
1
1
2
3
1
F122  
F122  
F122  
F120R  
F122R  
F180R  
F181R  
F188R  
F120W  
F122W  
F180W  
F181W  
F188W  
4
4
1
1
1
F074  
F181 or F071  
122275-01G  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
42" FULL hERRINGBONE BRICK MATRIx  
F074  
F074  
LEFT REFRAcTORY  
RED  
IvORY  
QTY  
F120  
F120  
F120  
FULL  
(112140-01)  
FULL  
(112140-05)  
6
F064R  
F068R  
F072R  
F074R  
F120R  
F163R  
F169R  
F175R  
F176R  
F177R  
F182R  
F064W  
F068W  
F072W  
F074W  
F120W  
F163W  
F169W  
F175W  
F176W  
F177W  
F182W  
4
4
2
2
4
1
1
1
1
1
1
F120  
F176  
F175 or F182  
F177  
F074  
F074  
REAR REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
(112140-01)  
FULL  
(112140-05)  
9
F063R  
F068R  
F072R  
F074R  
F089R  
F161R  
F168R  
F171R  
F178R  
F063W  
F068W  
F072W  
F074W  
F089W  
F161W  
F168W  
F171W  
F178W  
3
1
6
2
1
2
1
1
1
F171  
F074  
RIGHT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
FULL  
9
(112140-01)  
(112140-05)  
F071R  
F068R  
F072R  
F074R  
F100R  
F101R  
F162R  
F164R  
F165R  
F174R  
F071W  
F068W  
F072W  
F074W  
F100W  
F101W  
F162W  
F164W  
F165W  
F174W  
4
1
2
1
3
1
1
1
1
1
F162 or F184  
20  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
50" FULL hERRINGBONE BRICK MATRIx  
LEFT REFRAcTORY  
IvORY  
F074  
F074  
RED  
QTY  
F120  
F120  
F120  
FULL  
(112140-01)  
FULL  
(112140-05)  
6
F064R  
F068R  
F072R  
F064W  
F068W  
F072W  
4
4
2
F074R  
F120R  
F163R  
F169R  
F175R  
F176R  
F074W  
F120W  
F163W  
F169W  
F175W  
F176W  
2
4
1
1
1
1
F120  
F176  
F177R  
F182R  
F177W  
F182W  
1
1
F175 or F182  
F177  
REAR REFRAcTORY  
F074  
F074  
RED  
IvORY  
QTY  
FULL  
(112140-01)  
FULL  
(112140-05)  
12  
F063R  
F065R  
F068R  
F072R  
F074R  
F082R  
F063W  
F065W  
F068W  
F072W  
F074W  
F082W  
3
3
2
2
2
1
F089R  
F161R  
F168R  
F170R  
F178R  
F089W  
F161W  
F168W  
F170W  
F178W  
1
2
2
1
1
F168  
F168  
F178  
RIGHT REFRAcTORY  
F093  
F074  
F074  
RED  
IvORY  
FULL  
QTY  
9
FULL  
(112140-01)  
(112140-05)  
F068R  
F072R  
F074R  
F083R  
F084R  
F085R  
F093R  
F166R  
F167R  
F172R  
F173R  
F183R  
F068W  
F072W  
F074W  
F083W  
F084W  
F085W  
F093W  
F166W  
F167W  
F172W  
F173W  
F183W  
2
1
2
3
4
1
1
1
1
1
1
1
F167  
F166  
122275-01G  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
36" SPLIT STACKED BRICK MATRIx  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S047  
FULL  
S047  
FULL  
S047  
FULL  
S047  
S046  
S046  
S046  
FULL  
FULL  
FULL  
FULL  
FULL  
S050  
S050  
S050  
LEFT REFRAcTORY  
RED  
IvORY QTY  
FULL  
FULL  
16  
(112140-02) (112140-06)  
S043R  
S044R  
S045R  
S046R  
S047R  
S050R  
S095R  
S043W  
S044W  
S045W  
S046W  
S047W  
S050W  
S095W  
1
1
1
6
6
5
1
S046  
FULL  
S047  
S050  
S046  
S050  
S046  
FULL  
S047  
S045  
S044 or S095  
S043  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S048  
S049  
S048  
S049  
FULL  
S048  
FULL  
FULL  
FULL  
FULL  
FULL  
S048  
REAR REFRAcTORY  
S049  
S048  
S049  
FULL  
S049  
S048  
S049  
RED  
IvORY  
QTY  
FULL  
FULL  
17  
(112140-02)(112140-06)  
FULL  
FULL  
S048R  
S049R  
S051R  
S052R  
S048W  
S049W  
S051W  
S052W  
12  
10  
1
S048  
S049  
S048  
S049  
S048  
S049  
S048  
S049  
2
FULL  
S051  
S048  
S052  
S048  
S052  
S046  
FULL  
S047  
FULL  
S047  
FULL  
S047  
FULL  
S047  
FULL  
S047  
FULL  
S047  
S045  
RIGHT REFRAcTORY  
S050  
S050  
S050  
S050  
S050  
S054  
FULL  
FULL  
FULL  
FULL  
FULL  
RED  
IvORY  
QTY  
S046  
S046  
S046  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
16  
(112140-02) (112140-06)  
S044R  
S045R  
S046R  
S047R  
S050R  
S054R  
S095R  
S044W  
S045W  
S046W  
S047W  
S050W  
S054W  
S095W  
1
1
6
6
5
1
1
S046  
S046  
S044 or S095  
22  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
42" SPLIT STACKED BRICK MATRIx  
S050  
S050  
S050  
S050  
S050  
S050  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S046  
FULL  
FULL  
FULL  
FULL  
FULL  
LEFT REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
17  
S046  
S046  
S046  
S046  
S080  
(112140-02) (112140-06)  
S045R  
S046R  
S050R  
S076R  
S077R  
S080R  
S081R  
S045W  
S046W  
S050W  
S076W  
S077W  
S080W  
S081W  
1
5
6
6
6
1
1
S045  
or S081  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S078  
FULL  
S076  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S078  
FULL  
FULL  
REAR REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
FULL  
16  
(112140-02) (112140-06)  
S051R  
S076R  
S077R  
S078R  
S051W  
S076W  
S077W  
S078W  
2
12  
10  
2
FULL  
FULL  
FULL  
FULL  
FULL  
S051  
FULL  
FULL  
S051  
S050  
S046  
S050  
S046  
S050  
S046  
S050  
S046  
S050  
S046  
S050  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S077  
S077  
FULL  
FULL  
FULL  
FULL  
FULL  
S076  
RIGHT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
FULL  
17  
S076  
(112140-02) (112140-06)  
S077  
S077  
S045R  
S046R  
S050R  
S076R  
S077R  
S081R  
S082R  
S045W  
S046W  
S050W  
S076W  
S077W  
S081W  
S082W  
1
5
6
6
6
1
1
S076  
S076  
S076  
S077  
S077  
S082  
S045 or S081  
S076  
122275-01G  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
50" SPLIT STACKED BRICK MATRIx  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S077  
S076  
S045 or S096  
S046  
S046  
S046  
S046  
S046  
S046  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S095  
S050  
S050  
S050  
LEFT REFRAcTORY  
RED  
IvORY  
QTY  
FULL  
FULL  
16  
(112140-02) (112140-06)  
S043R  
S045R  
S046R  
S050R  
S076R  
S077R  
S095R  
S096R  
S043W  
S045W  
S046W  
S050W  
S076W  
S077W  
S095W  
S096W  
1
1
6
5
6
6
1
1
S050  
S050  
S043  
S077  
S048  
S048  
S048  
S048  
S048  
S048  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S048  
S049  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
S049  
S048  
S049  
S048  
S049  
S048  
S049  
S048  
S049  
S048  
S052  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
REAR REFRAcTORY  
S049  
S049  
S049  
RED  
IvORY  
QTY  
FULL  
FULL  
28  
(112140-02) (112140-06)  
S048R  
S049R  
S051R  
S052R  
S048W  
S049W  
S051W  
S052W  
12  
10  
2
2
S049  
S052  
FULL  
S051  
FULL  
S051  
S046  
FULL  
S076  
RIGHT REFRAcTORY  
FULL  
FULL  
S077  
S050  
S046  
S050  
S046  
S050  
S046  
S050  
S046  
S050  
S046  
S054  
RED  
IvORY  
QTY  
S076  
S076  
S076  
FULL  
FULL  
FULL  
FULL  
FULL  
16  
S077  
S077  
S077  
FULL  
FULL  
FULL  
FULL  
FULL  
FULL  
(112140-02) (112140-06)  
S045R  
S046R  
S050R  
S054R  
S076R  
S077R  
S095R  
S096R  
S045W  
S046W  
S050W  
S054W  
S076W  
S077W  
S095W  
S096W  
1
6
5
1
6
6
1
1
S076  
S076  
FULL  
FULL  
S077  
S077  
FULL  
S095  
FULL  
S045 or S096  
24  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
36" SPLIT hERRINGBONE BRICK MATRIx  
S003  
LEFT REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
12  
(112140-02) (112140-06)  
S001R  
S002R  
S003R  
S004R  
S032R  
S058R  
S069R  
S071R  
S072R  
S073R  
S074R  
S075R  
S103R  
F120R  
S001W  
S002W  
S003W  
S004W  
S032W  
S058W  
S069W  
S071W  
S072W  
S073W  
S074W  
S075W  
S103W  
F120W  
1
1
1
1
1
7
7
1
1
1
1
1
1
1
F194R  
F194W  
1
F120  
S003  
S073  
S003  
REAR REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
12  
(112140-02) (112140-06)  
S001R  
S002R  
S003R  
S004R  
S014R  
S015R  
S059R  
S061R  
S062R  
S090R  
S091R  
F071R  
F120R  
F129R  
S001W  
S002W  
S003W  
S004W  
S014W  
S015W  
S059W  
S061W  
S062W  
S090W  
S091W  
F071W  
F120W  
F129W  
2
1
2
1
12  
1
1
1
1
1
1
1
1
1
F129  
S003  
F120  
RIGHT REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
S064  
(112140-02) (112140-06)  
12  
1
1
1
1
7
1
1
6
1
1
1
1
1
1
1
1
1
S001R  
S002R  
S003R  
S004R  
S055R  
S056R  
S057R  
S058R  
S063R  
S064R  
S065R  
S066R  
S067R  
S068R  
F129R  
F130R  
F193R  
S001W  
S002W  
S003W  
S004W  
S055W  
S056W  
S057W  
S058W  
S063W  
S064W  
S065W  
S066W  
S067W  
S068W  
F129W  
F130W  
F193W  
F129  
F130  
122275-01G  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
42" SPLIT hERRINGBONE BRICK MATRIx  
S003  
S003  
LEFT REFRAcTORY  
S087  
S085  
S085  
RED  
IvORY  
QTY  
19  
FULL  
FULL  
(112140-02) (112140-06)  
S001R  
S002R  
S003R  
S004R  
S054R  
S074R  
S075R  
S085R  
S087R  
S088R  
S103R  
F071R  
F131R  
S001W  
S002W  
S003W  
S004W  
S054W  
S074W  
S075W  
S085W  
S087W  
S088W  
S103W  
F071W  
F131W  
2
9
2
1
1
1
1
7
1
1
1
1
1
S085  
S085  
S085  
S085  
S085  
F054 or S088  
S003  
S003  
REAR REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
12  
(112140-02) (112140-06)  
S001R  
S002R  
S003R  
S004R  
S059R  
S060R  
S061R  
S062R  
S074R  
S083R  
S084R  
F071R  
F120R  
F129R  
S001W  
S002W  
S003W  
S004W  
S059W  
S060W  
S061W  
S062W  
S074W  
S083W  
S084W  
F071W  
F120W  
F129W  
2
2
2
7
1
1
1
1
6
1
1
1
1
1
F129  
F120  
S003  
S003  
RIGHT REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
18  
S089  
S089  
S089  
S089  
(112140-02) (112140-06)  
S001R  
S002R  
S003R  
S004R  
S065R  
S074R  
S086R  
S089R  
S092R  
S093R  
S094R  
S104R  
F054R  
S001W  
S002W  
S003W  
S004W  
S065W  
S074W  
S086W  
S089W  
S092W  
S093W  
S094W  
S104W  
F054W  
2
8
2
2
1
1
1
8
1
1
1
1
2
S089  
S089  
S089  
S089  
S092 or S093  
F054  
F054  
S094  
26  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
50" SPLIT hERRINGBONE BRICK MATRIx  
S003  
S003  
LEFT REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
(112140-02) (112140-06) 18  
S001R  
S002R  
S003R  
S004R  
S007R  
S067R  
S093R  
S097R  
S098R  
S099R  
S105R  
S106R  
F120R  
F130R  
F137R  
S001W  
S002W  
S003W  
S004W  
S007W  
S067W  
S093W  
S097W  
S098W  
S099W  
S105W  
S106W  
F120W  
F130W  
F137W  
2
1
2
2
8
1
1
6
1
1
1
1
1
1
1
S093 or S099 F120  
F130  
S003  
S003  
REAR REFRAcTORY  
RED  
FULL  
IvORY  
FULL  
QTY  
(112140-02) (112140-06) 24  
S001R  
S002R  
S003R  
S004R  
S006R  
S008R  
S012R  
S059R  
S060R  
S062R  
S100R  
F129R  
F136R  
S001W  
S002W  
S003W  
S004W  
S006W  
S008W  
S012W  
S059W  
S060W  
S062W  
S100W  
F129W  
F136W  
2
2
2
2
13  
1
1
2
2
2
1
3
1
F129  
F129  
F129  
RIGHT REFRAcTORY  
S003  
S003  
RED  
FULL  
IvORY  
FULL  
QTY  
F195  
(112140-02) (112140-06( 18  
S007  
S001R  
S002R  
S003R  
S004R  
S007R  
S067R  
S075R  
S088R  
S093R  
S101R  
S102R  
S107R  
S108R  
F054R  
F139R  
F195R  
S001W  
S002W  
S003W  
S004W  
S007W  
S067W  
S075W  
S088W  
S093W  
S101W  
S102W  
S107W  
S108W  
F054W  
F139W  
F195W  
1
2
2
1
7
2
1
1
1
7
1
1
1
1
1
1
S007  
S007  
S007  
S007  
S007  
S007  
S102  
S088 or F054  
F139  
122275-01G  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
ture by moving trowel in the direction of the  
GROUTING INSTRUcTIONS  
joint. Grout mixture in the joint should now  
be flush with brick surface. If not enough  
grout is applied into each space, grout may  
fall out after burning.  
Material provided:  
1 or 2 - 10 lb. bags of cement (depending  
on model)  
1 or 2 - 10 lb. bags of sand (depending  
on model)  
8. Using a joint striker, force grout mixture  
into joint and sweep back and forth  
until grout is smooth and round. If grout  
becomes too shallow, add more grout  
mixture with piping bag and strike again.  
Material required:  
1 - Piping bag  
1 - Joints striker  
1 - Heavy duty mixing bucket  
1 - Trowel  
9. Continue procedure around each group of  
6 bricks until an entire panel is finished.  
1. Moisten brick surface with damp sponge  
or spray bottle just prior to application.  
When bricks are wet, any excess grout  
mixture on bricks will easily wipe off.  
10. Using trowel, scrape in direction of joints  
to remove any grout that may have col-  
lected around bricks during striking. If  
desired, take a moist sponge and lightly  
sweep over bricks to remove any grout  
that may have gotten on bricks. DO NO  
PRESS HARD OR RUB IN A CIRCULAR  
MOTION. This will press the grout into  
brick and turn brick a different color.  
2. In a heavy duty mixing bucket, pour seven  
(4-1/2) cups of water. Add 5 lbs. (half of a  
bag) of sand and 5 lbs (half of a bag) of  
cement. Mix together well using a power  
drill with mixing wand attachment to a yo-  
gurt like consistency, not adding enough  
water can lead to grout falling out after  
burning.  
Allow 72 hours before  
operating fireplace.  
3. The overall length of piping bag should be  
about 16". If the bag is longer than 16",  
cut it down to size by removing end with  
larger opening. This will make the bag  
easier to handle.  
4. Put 2 to 3 cups of grout mixture into piping  
bag making sure the smaller opening is  
downward and over a moist towel to avoid  
spilling. Place a wet towel over the bucket  
making sure it is directly on the surface of  
grout mixture. This will keep the mixture  
moist and it will not dry out before use.  
Figure 16 - Grouting Brick  
5. Begin grouting by first doing a “Filler  
Pass”. This is done by filling the joint about  
3/4 full with grout mixture. It is important  
to work with only 6 bricks at a time so  
INSTALLING FIREpLAcE HOOD  
AND ScREEN  
grout doesn't have time to set up before 1. Attach hood to firebox using screws pro-  
striking.  
vided (see Figure 17, page 29).  
6. Complete a “Finishing Pass” around 6 2. Mount screen rod brackets on left and right  
bricks you just put filler pass around. This  
is done by slowly filling in remainder of the  
joint with a thick amount of grout mixture.  
Mixture should be a little higher than the  
brick surface.  
side of smoke shelf with #8 x 1/2" screws  
provided (see Figure 18, page 29).  
3. Slide round end of screen rod into rings  
at top of screen. Attach one push-on nut  
to end of rod before attaching last ring of  
screen.  
7. Using a trowel, remove excess grout mix-  
4. Insert round end of rod into rod bracket  
on left side of fireplace.  
28  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INsTAllATIoN  
Continued  
5. Mount flat end of screen rod with #10 x 5/8"  
Screen  
Rod  
to center of smoke shelf (see Figure 18).  
Fireplace Front  
Smoke Shelf  
Bracket  
6. Install other screen rod in same manner.  
Push  
On Nut  
Screen  
Rod  
Screws  
Figure 17 - Screw and Hood Placement  
Ring  
Screen  
Figure 18 - Installing Fireplace Screen  
TeCHNICAl serVICe  
You may have further questions about When calling, please have your model and  
installation, operation, or troubleshooting. serial numbers of your firebox ready.  
If so, contact FMI PRODUCTS, LLC at  
1-866-328-4537.  
You can also visit FMI PRODUCTS, LLC’s  
web site at www.fmiproducts.com.  
rePlACeMeNT PArTs  
Note: Use only original replacement parts. When calling FMI PRODUCTS, LLC, have  
This will protect your warranty coverage for ready  
parts replaced under warranty.  
• your name  
Contact authorized dealers of this product.  
If they can’t supply original replacement  
part(s), call FMI PRODUCTS, LLC at  
1-866-328-4537.  
• your address  
• model and serial numbers of your firebox  
• how firebox was malfunctioning  
• type of gas used (propane/LP or natural  
gas)  
• purchase date  
Usually, we will ask you to return the part to  
the factory.  
122275-01G  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PArTs  
MODELS (V)qM36(SR,SI,hR,hI), VCM-36q, (V)qM42(SR,SI,hR,hI),  
VCM-42q, (V)qM50(SR,SI,hR,hI), VCM-50q  
11  
10  
13  
12  
9
14  
8
17/18  
16  
7
15  
6
13  
5
24  
1
19  
19  
22  
21  
4
13  
14  
3
23  
26  
15  
16  
2
17/18  
26  
25  
16  
20  
30  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PArTs  
This list contains replaceable parts used in your firebox. When ordering parts, follow the  
instructions listed under Replacement Parts on page 29 of this manual.  
q
q
q
M36, VCM-36 M42, VCM-42 M50, VCM-50  
KEY  
q
q
q
NO. PART NO.  
DEScRIpTION  
qTY.  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
6
4
2
4
2
2
6
1
1
1
1
1
1
1
2
2
2
2
2
2
(V)  
(V)  
(V)  
1
2
3
4
**  
**  
**  
Face Assembly  
Firebox Bottom Assembly  
Firebox Bottom  
120826-01 Hearth Brick Panel, 36"  
120826-02 Hearth Brick Panel, 42"  
120826-03 Hearth Brick Panel, 50"  
5
6
7
8
9
**  
**  
**  
**  
**  
Firebox Surround  
Firebox Top  
Insulation Pan Support  
Insulation Pan  
Top Insulation  
10 110454-03 Fireplace Top, 36"  
110454-02 Fireplace Top, 42"  
110454-01 Fireplace Top, 50"  
11 23490SA  
12 **  
13 109720-02 Clearance Spacer  
14 117891-01 Fireplace Handle Bracket  
15 20042  
16 21171  
17 109752-01 Conduit One  
Standoff  
Fireplace Surround Assembly  
Outside Air Cover Plate  
Gas Conduit Cover  
18 109752-02 Conduit Two  
19 20106  
20 **  
Nailing Strap  
Heat Shield Support  
21 123298-01 Ash Box Assembly  
22  
23  
**  
**  
Ash Box Ring  
Hearth Support Brace  
24 109511-04 Hood  
109511-05 Hood  
109511-06 Hood  
25 117566-03 Screen  
117566-01 Screen  
117566-02 Screen  
26 117568-03 Screen Rod  
117568-01 Screen Rod  
117568-02 Screen Rod  
pARTS AvAILAbLE NOT SHOWN  
see page 32 Brick Panel Assemblies with Brick  
Housings (1 each, right, left, rear)  
1
** Not a field replaceable part.  
122275-01G  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PArTs  
MODELS (V)qM36(SR,SI,hR,hI), (V)qM42(SR,SI,hR,hI), (V)qM50(SR,SI,hR,hI),  
MK-36(SS,Sh)-(R)(I), MK-42(Sh,SS)-(R)(I), MK-50(Sh,SS)-(R)(I)  
This list contains replaceable parts used in your firebox. When ordering parts, follow the  
instructions listed under Replacement Parts on page 29 of this manual.  
All parts are housing Panel Assemblies.  
For Brick part numbers see pages 15 thru 27.  
PART NO.  
DEScRIpTION  
qTY.  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
122317-02 36" Full Stack Left  
122319-02 42" Full Stack Left  
122321-02 50" Full Stack Left  
122323-02 36" Full Herringbone Left  
122327-02 42" Full Herringbone Left  
122327-02 50" Full Herringbone Left  
122317-01 36" Full Stack Right  
122319-01 42" Full Stack Right  
122321-01 50" Full Stack Right  
122323-01 36" Full Herringbone Right  
122325-01 42" Full Herringbone Right  
122327-01 50" Full Herringbone Right  
122354-01 36" Full Stack Rear  
122354-02 42" Full Stack Rear  
122354-03 50" Full Stack Rear  
122356-01 36" Full Herringbone Rear  
122356-02 42" Full Herringbone Rear  
122356-03 50" Full Herringbone Rear  
1
1
PART NO.  
DEScRIpTION  
qTY.  
1
120842-01 36" Split Stack Left  
120842-02 42" Split Stack Left  
1
120842-03 50" Split Stack Left  
1
120845-01 36" Split Herringbone Left  
120845-02 42" Split Herringbone Left  
120845-03 50" Split Herringbone Left  
120843-01 36" Split Stack Right  
120843-02 42" Split Stack Right  
120843-03 50" Split Stack Right  
120846-01 36" Split Herringbone Right  
120846-02 42" Split Herringbone Right  
120846-03 50" Split Herringbone Right  
120844-01 36" Split Stack Rear  
120844-02 42" Split Stack Rear  
120844-03 50" Split Stack Rear  
120847-01 36" Split Herringbone Rear  
120847-02 42" Split Herringbone Rear  
120847-03 50" Split Herringbone Rear  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NoTes  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
122275-01G  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NoTes  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
34  
122275-01G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NoTes  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
_____________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
______________________________________________________  
122275-01G  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WArrANTy  
KeeP THIs WArrANTy  
Model (located on product or identification tag)_____________________________  
Serial No. (located on product or identification tag)__________________________  
Date Purchased __________________________  
Keep receipt for warranty verification.  
FMI ProdUCTs, llC lIMITed WArrANTIes  
New products  
Standard Warranty: FMIPRODUCTS, LLCwarrantsthisnewproductandanypartsthereoftobefreefromdefects  
in material and workmanship for a period of four (4) years from the date of first purchase from an authorized dealer  
provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s  
warnings and instructions.  
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date  
of first purchase.  
Factory Reconditioned products  
Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be  
free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer  
provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s  
warnings and instructions.  
Terms common to All Warranties  
The following terms apply to all of the above warranties:  
Always specify model number and serial number when contacting the manufacturer. To make a claim under this  
warranty the bill of sale or other proof of purchase must be presented.  
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only  
when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.  
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow-  
ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by  
FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI  
PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement  
parts voids this warranty.  
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs,  
unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of  
the owner.  
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper  
installation, lack of proper maintenance, tampering, or alteration(s).  
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty  
excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all  
implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) years on  
new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC  
makes no other warranties regarding this product.  
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not  
be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential  
damages.  
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental  
or consequential damages, so the above limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
For information about this warranty contact:  
2701 S. Harbor Blvd.  
Santa Ana, CA 92704  
1-866-328-4537  
122275-01  
Rev. G  
04/10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edelbrock Automobile Parts 1472 User Manual
Edimax Technology Network Router BR6101 User Manual
Electro Voice Portable Speaker MTH 2 94B User Manual
Estate Cordless Telephone TERZOWOY User Manual
Franke Consumer Products Plumbing Product FF 1800 User Manual
Friedrich Air Conditioner CP08A10 User Manual
GE Conference Phone 29487 User Manual
Genelec Portable Speaker 8040A User Manual
GE Water System 263 User Manual
Go Video VCR DDV9000 User Manual