Extron electronic Stereo Receiver FOX HD SDI User Manual

User’s Manual  
FOX HD-SDI  
Multi-Rate SDI Fiber Optic Transceiver  
Extron Electronics, USA  
1230 South Lewis Street  
Anaheim, CA 92805  
800.633.9876 714.491.1500  
FAX 714.491.1517  
Extron Electronics, Europe  
Beeldschermweg 6C  
3821 AH Amersfoort, The Netherlands  
+800.3987.6673 +31.33.453.4040  
FAX +31.33.453.4050  
Extron Electronics, Asia  
135 Joo Seng Rd. #04-01  
PM Industrial Bldg., Singapore 368363  
+800.7339.8766 +65.6383.4400  
FAX +65.6383.4664  
Extron Electronics, Japan  
Kyodo Building, 16 Ichibancho  
Chiyoda-ku, Tokyo 102-0082  
Japan  
68-1384-01 Rev. A  
11 07  
+81.3.3511.7655 FAX +81.3.3511.7656  
© 2007 Extron Electronics. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
警告  
安全须知 中文  
这个符号提示用户该设备用户手册中  
电源 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备  
必 须 使 用 有 地 线 的 供 电 系 统 供 电 。 第 三 条 线  
( 地 线 ) 是 安 全 设 施 , 不 能 不 用 或 跳 过 。  
拔掉电源 为安全地从设备拔掉电源,请拔掉所有设备后  
或桌面电源的电源线,或任何接到市电系统的电源线。  
电源线保护 妥善布线, 避免被踩踏,或重物挤压。  
维护 所有维修必须由认证的维修人员进行。 设备内部没  
有用户可以更换的零件。为避免出现触电危险不要自己  
试图打开设备盖子维修该设备。  
有重要的操作和维护说明。  
这个符号警告用户该设备机壳内有暴  
露的危险电压,有触电危险。  
注意  
阅读说明书 用 户 使 用 该 设 备 前 必 须 阅 读 并 理  
解 所 有 安 全 和 使 用 说 明 。  
通风孔 有些设备机壳上有通风槽或孔,它们是用来防止  
机内敏感元件过热。 不要用任何东西挡住通风孔。  
锂电池 不正确的更换电池会有爆炸的危险。 必须使用与  
厂家推荐的相同或相近型号的电池。 按照生产厂的建  
议处理废弃电池。  
保存说明书 用户应保存安全说明书以备将来使  
用。  
遵守警告 用户应遵守产品和用户指南上的所有安  
全和操作说明。  
避免追加 不要使用该产品厂商没有推荐的工具或  
追加设备,以避免危险。  
FCC Class A Notice  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this  
device may not cause harmful interference, and (2) this device must accept any interference received,  
including interference that may cause undesired operation. The Class A limits are designed to  
provide reasonable protection against harmful interference when the equipment is operated in  
a commercial environment. This equipment generates, uses, and can radiate radio frequency  
energy and, if not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is likely to  
cause harmful interference, in which case the user will be required to correct the interference at his  
own expense.  
This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used  
with the unit to ensure compliance with FCC emissions limits.  
N
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide — FOX HD-SDI  
The FOX HD-SDI is a transceiver that can function as a  
transmitter and/or a receiver. At least two units are required  
for a transmitter-receiver system with at least one fiber optic  
cable linking each two units. The FOX HD-SDI is available in  
single mode or multimode versions.  
N
Connect and operate two or more FOX HD-SDI units as follows:  
Step 1  
Power off all equipment. If desired, mount the units in racks.  
Step 2  
MODE  
MODE  
MODE  
Use the rear panel  
1 down  
2 down  
1 down  
2 up  
1 up  
2 down  
Mode DIP switches  
to configure each  
unit to be installed  
in the system as  
a bidirectional  
1
2
1
2
1
2
Bidirectional  
Transceiver  
Transmitter  
Receiver with  
Loop-through  
transceiver, a transmitter, or a receiver as shown above right.  
The drawings below and on QS-2 show the signal flow for  
the three different FOX HD-SDI configurations. For more  
information on the various modes and their capabilities, see  
"Transceiver configurations" in chapter 1, "Introduction".  
N
Step 3  
Transmitting unit — Connect an HD-SDI, SDI, or 3G-SDI  
video source to the unit's HD/SDI In BNC connector.  
HD/SDI IN  
Step 4  
Video  
Source  
Transmitting unit —  
If the FOX HD-SDI  
Video from  
Source  
To Receiver  
is configured as a  
FOX HDSDI  
OPTICAL  
POWER  
12V  
0.3A MAX  
transmitter, and if desired,  
connect one or two local  
monitors to the unit's  
Buffered Outputs BNC  
connectors. These two  
BNCs output the same  
MODE  
1
2
HD/SDI IN  
BUFFERED OUTPUTS  
Tx  
Rx  
Transmitter  
HD-SDI, SDI, or 3G-SDI video that was input in step 3.  
Step 5  
Both units — Connect  
a fiber cable between  
the transmitting unit's  
Optical Tx connector  
and the receiving unit's Optical Rx connector.  
FOX HD-SDI • Quick Start Guide  
QS-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide — FOX HD-SDI, cont’d  
Table of Contents  
Step 6  
Receiving unit — Connect one or two monitors to the unit's Buffered  
Outputs BNC connectors.  
To/from 2nd Video from 2nd  
Video  
Unit configured as  
bidirectional transceiver —  
Both BNCs output  
the HD-SDI, SDI, or  
3G-SDI video that was  
transmitted across the  
fiber cable.  
Source  
Transceiver  
Transceiver  
FOX HDSDI  
OPTICAL  
POWER  
12V  
0.3A MAX  
MODE  
1
2
HD/SDI IN  
BUFFERED OUTPUTS  
Tx  
Rx  
Bidirectional  
Transceiver  
Video from  
Transmitter  
Source  
Daisy-chained  
Receiver Transmitter  
Unit configured as  
receiver — Output 2 BNC  
only outputs the  
FOX HDSDI  
OPTICAL  
POWER  
12V  
0.3A MAX  
MODE  
transmitted video.  
1
2
HD/SDI IN  
BUFFERED OUTPUTS  
Tx  
Rx  
Receiver with  
Loop-through  
Step 7  
Receiving unit — If desired, connect a fiber cable between the  
receiving unit's Optical Tx connector and another unit's Optical Rx  
connector.  
Unit configured as bidirectional transceiver — Connect the fiber  
cable to the transmitting unit.  
Unit configured as a receiver — Connect the fiber cable to another  
receiving unit for daisy chaining.  
Up to 10 receivers can be daisy-chained in this manner.  
N
Step 8  
Receiving unit configured as bidirectional transceiver —  
Connect a video source to the unit's HD/SDI In BNC connector.  
HD/SDI IN  
Step 9  
Transmitting unit configured as a bidirectional  
transceiver — Connect one or two local monitors to the  
unit's Buffered Outputs BNC connectors. These two  
BNCs output the same video that was input in step 8.  
1
2
BUFFERED OUTPUTS  
Step 10  
68-1384-01.Rev. A  
Connect power to all FOX units and to all connected video sources  
and displays.  
11.07  
All trademarks mentioned in this manual are the properties of their respective owners.  
FOX HD-SDI • Quick Start Guide  
FOX HD-SDI • Table of Contents  
QS-2  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents, cont'd  
FOX HD-SDI  
Chapter One  
1
Introduction  
About.this.Manual  
About.the.FOX.HD-SDI  
Features  
FOX HD-SDI • Table of Contents  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Introduction  
The FOX HD-SDI units output continuous,  
invisible light, which may be harmful and  
dangerous to the eyes; use with caution.  
W
About the FOX HD-SDI  
The Extron FOX HD-SDI product family consists of two models  
(MM and SM) of high performance digital (HD-SDI, SDI, or  
3G-SDI) video fiber optic transceivers. The transmitted signal  
can include any audio or unidirectional serial data that is  
embedded in the input video.  
Do not look into the rear panel fiber optic  
cable connectors or into the fiber optic cables,  
themselves.  
All transceivers in the system must be the same model (all  
singlemode or all multimode).  
N
Plug the attached dust caps into the optical  
transceivers when the fiber optic cable is  
unplugged.  
Transceiver configurations  
The transceiver can be configured via its rear panel Mode DIP  
switches to operate in one of three ways:  
About this Manual  
This manual contains information about the following Extron  
FOX HD-SDI fiber optic transceiver products:  
Bidirectional transceiver  
Transmitter  
Receiver  
FOX HD-SDI MM, a multimode, long distance  
(up to 500 m [1,640']) transceiver  
See item , "Mode switches", on page 2-11 to set the  
configuration.  
N
FOX HD-SDI SM, a singlemode, very long distance  
(up to 30 km [18.75 miles]) transceiver (figure 1-1)  
Daisy Chain Numerous  
Receivers  
Bidirectional transceiver  
In this manual, the term "transceiver" refers to any FOX  
HD-SDI; the term "bidirectional transceiver" refers to a  
FOX HD-SDI configured as described in this section.  
N
HD-SDI Broadcast  
Monitors  
Although the description below does allow connection of  
a FOX HD-SDI configured as transmitter or receiver,  
the typical configuration is as shown: two bidirectional  
transceivers.  
N
T
U
L
P
T
D
A
IC  
H
T
X
O
P
O
U
B
IG  
F
N
O
C
x
R
x
T
X
I
D
S
12V MA  
0.2A  
/
D
H
Extron  
Up to 30 km (18.75 miles)  
on singlemode ꢀber using  
SM Model  
FOX HD-SDI  
Fiber Optic  
Transceiver  
A FOX HD-SDI that is configured as a bidirectional transceiver  
(figure 1-2) inputs digital video on its SDI/HD-SDI Input BNC.  
The transceiver converts the video input to a proprietary signal  
and transmits the video over a fiber link to another FOX HD-SDI  
that is configured as a bidirectional transceiver or as a receiver.  
HD-SDI Broadcast  
Monitors  
S
S
T
U
X
O
L
P
T
D
A
IC  
H
T
P
O
F
U
B
IG  
F
N
O
C
x
R
x
T
HD-SDI  
In From  
Source A  
HD-SDI  
In From  
Source B  
HD-SDI HD-SDI  
Out From Out From  
Source B Source B  
HD-SDI HD-SDI  
Out From Out From  
Source A Source A  
X
D
S
12V MA  
0.2A  
/
D
H
Extron  
FOX HD-SDI  
Fiber Optic  
Transceiver  
FOX HDSDI  
OPTICAL  
FOX HDSDI  
OPTICAL  
POWER  
12V  
0.3A MAX  
POWER  
12V  
0.3A MAX  
MODE  
MODE  
1
2
1
2
HD/SDI IN  
HD/SDI IN  
HD-SDI Camera  
BUFFERED OUTPUTS  
BUFFERED OUTPUTS  
Tx  
Rx  
Tx  
Rx  
Figure 1-1 — Typical FOX HD-SDI application  
FOX HD-SDI  
FOX HD-SDI  
The two products are physically and functionally identical,  
with the exception of the effective range of transmission.  
In this manual, the term "FOX HD-SDI" refers to either  
product.  
N
Configured as bidirectional transceiver  
Configured as bidirectional transceiver  
Figure 1-2 — Bidirectional transceiver connections  
FOX HD-SDI • Introduction  
FOX HD-SDI • Introduction  
1-2  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction, cont’d  
A bidirectional transceiver can also simultaneously receive  
a proprietary signal from another transceiver (in any  
Features  
Extends HD-SDI, SDI, and 3G-SDI signals very long distances  
configuration) on its Optical Rx port, convert the proprietary  
signal to back to the original format digital video, and output  
the video on its own two Buffered Outputs BNC connectors.  
over a single fiber — The FOX HD-SDI supports multi-  
rate SDI at rates up to 2.97 Gbps, and complies with  
SMPTE 259M-C, 292M, 424M, and ITU digital video  
standards.  
Transmitter and receiver  
Video input — When it is configured as a transmitter, the  
Although the description below does allow connection of a  
FOX HD-SDI configured as a bidirectional transceiver, the  
typical configuration is as shown: a transmitter and one or  
more receivers.  
N
FOX HD-SDI inputs digital video on a BNC connector.  
HD-SDI loop-through — The transceiver has two Buffered  
SDI/HD-SDI BNC connectors that allows connection of  
a local monitor when the transceiver is configured as a  
transmitter.  
A FOX HD-SDI that is configured as a transmitter (figure 1-3)  
inputs digital video on its HD/SDI Input BNC. The transmitter  
converts the video input to a proprietary signal and transmits  
the video over a fiber link to a FOX HD-SDI that is configured as  
a receiver or as a bidirectional transceiver. The transmitter also  
simultaneously outputs the digital video on its two Buffered  
Outputs BNCs.  
Video output — The transceiver outputs digital video on one  
or two Buffered SDI/HD-SDI BNC connectors when it is  
configured as a bidirectional transceiver or a receiver.  
Dual buffered outputs — When the FOX HD-SDI is configured  
as a transmitter, the SDI/HD-SDI BNC output connectors  
can be used for previewing the video on a local monitor.  
FOX HD-SDI(s)  
Configured as receiver(s)  
Input equalization and reclocking on buffered outputs — The  
FOX HD-SDI automatically equalizes incoming multi-  
rate SDI signals, and reshapes and restores signals on its  
buffered outputs.  
HD-SDI  
In From  
Source A  
HD-SDI HD-SDI  
Out From Out From  
Source A Source A  
HD-SDI  
Out From  
Source A  
Transmitted HD-SDI  
from source A  
FOX HDSDI  
OPTICAL  
FOX HDSDI  
OPTICAL  
POWER  
12V  
0.3A MAX  
POWER  
12V  
0.3A MAX  
MODE  
MODE  
Daisy chain capability — Up to 10 transceivers can be daisy  
chained to send the video to multiple locations when one  
of more units are configured as receivers.  
1
2
1
2
HD/SDI IN  
HD/SDI IN  
BUFFERED OUTPUTS  
BUFFERED OUTPUTS  
Tx  
Rx  
Tx  
Rx  
Real-time status LED indicators for troubleshooting and  
monitoring  
FOX HD-SDI  
FOX HD-SDI  
Configured as transmitter  
Configured as receiver  
1" high, quarter rack width, metal enclosures — With low  
profile enclosures, the transceiver can be discreetly  
installed in a variety of locations, such as behind a plasma  
or LCD flat-panel display.  
Figure 1-3 — Transmitter-to-receiver connections  
A FOX HD-SDI that is configured as a receiver receives a  
proprietary signal on its Rx fiber optic port. The receiver  
converts the proprietary signal back to original HD-SDI, SDI,  
or 3G-SDI video and outputs the video on only one of its own  
Buffered Output BNC connectors, Output 2.  
Rack mountable — The unit is rack mountable in any  
conventional 19" wide rack, using any of a variety of  
Extron's rack shelves.  
Power — The unit's 100 VAC to 240 VAC, external power supply  
The receiver converts the second digital video signal that it  
created from the optical input back into a proprietary signal  
and outputs it on the Optical Rx port over a fiber link to another  
FOX HD-SDI that is configured as a receiver or as a bidirectional  
transceiver.  
provides worldwide power compatibility.  
Up to 10 receivers can be daisy-chained in this manner.  
N
FOX HD-SDI • Introduction  
FOX HD-SDI • Introduction  
1-4  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Introduction, cont’d  
FOX HD-SDI  
Chapter Two  
2
Installation and Operation  
Mounting.the.Unit  
Connections.and.Settings  
Operation  
FOX HD-SDI • Introduction  
1-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and Operation  
Mounting instructions  
Mounting the Unit  
For optional rack mounting, mount the transceiver on any of the  
following rack shelves:  
Installation and service must be performed by  
authorized personnel only.  
C
RSF 123 3.5" deep 1U VersaTools® rack shelf kit  
(part #60-190-20) (figure 2-1)  
The 1" high, quarter-rack width transceiver can be placed on  
a tabletop, mounted on a rack shelf, mounted under a desk or  
tabletop, or mounted on a projector bracket.  
RSB 123 3.5" deep 1U VersaTools rack shelf (part #60-604-20)  
RSU 126 6" deep 1U universal rack shelf kit  
(part #60-190-10)  
Tabletop placement  
Affix the four included rubber feet to the bottom of the unit and  
place it in any convenient location.  
RSB 126 6" deep 1U basic rack shelf (part #60-604-10)  
RSU 129 9.5" deep 1U universal rack shelf kit  
(part #60-190-01) (figure 2-2 on the next page)  
Rack mounting  
RSB 129 9.5" deep 1U basic rack shelf (part #60-604-01)  
UL requirements  
The following Underwriters Laboratories (UL) requirements  
pertain to the installation of the FOX HD-SDI transmitter or  
receiver into a rack (figure 2-1).  
VersaTools Rack Shelf  
1.  
Elevated operating ambient temperature — If installed in  
a closed or multi-unit rack assembly, the operating ambient  
temperature of the rack environment may be greater  
than room ambient. Therefore, consider installing the  
equipment in an environment compatible with the +122 °F  
(50 °C) maximum ambient temperature (Tma) specified by  
Extron.  
1/4 Rack Width Front  
False Faceplate  
2.  
3.  
4.  
Reduced air flow — Installation of the equipment in a rack  
should be such that the amount of air flow required for  
safe operation of the equipment is not compromised.  
Mechanical loading — Mounting of the equipment in  
the rack should be such that a hazardous condition is not  
achieved due to uneven mechanical loading.  
Use 2 mounting holes on  
opposite corners.  
(2) 4-40 x 3/16"  
Screws  
Circuit overloading — Consideration should be given to  
the connection of the equipment to the supply circuit and  
the effect that overloading of the circuits might have on  
overcurrent protection and supply wiring. Appropriate  
consideration of equipment nameplate ratings should be  
used when addressing this concern.  
Figure 2-1 — Mounting the transceiver on a  
VersaTools rack shelf  
On the non-VersaTools rack shelves, the transceiver unit can be  
mounted in the front or the rear of the rack.  
5.  
Reliable earthing (grounding) — Reliable earthing  
of rack-mounted equipment should be maintained.  
Particular attention should be given to supply connections  
other than direct connections to the branch circuit (such as  
the use of power strips).  
1.  
2.  
If installed, remove the feet from the bottom of the unit.  
Mount the unit on the shelf, using two 4-40 x 3/16" screws  
in opposite (diagonal) corners to secure the unit to the  
shelf.  
3.  
4.  
Install false faceplate(s) or other unit(s) to the rack shelf.  
Insert the shelf into the rack, aligning the holes in the shelf  
with those of the rack.  
FOX HD-SDI • Installation and Operation  
FOX HD-SDI • Installation and Operation  
2-2  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and Operation, cont’d  
1U Universal Rack Shelf  
1/2 Rack Width  
Front False  
Faceplate  
1/4 Rack Width  
Front False  
Faceplate  
Both front false faceplates  
use 2 screws.  
(2) 4-40 x 3/16"  
Screws  
Use 2 mounting holes on  
opposite corners.  
Figure 2-3 — Under-desk mounting  
6.  
Align the installed screws with the slots in the mounting  
brackets, and place the transceiver against the surface,  
with the screws through the bracket slots.  
Figure 2-2 — Mounting the transceiver on a standard  
rack shelf  
5.  
Secure the shelf to the rack using the supplied machine  
screws.  
7.  
Slide the transceiver slightly forward or back, then tighten  
all four screws to fasten it in place.  
Furniture mounting  
The transceiver can be mounted under a horizontal surface using an  
optional MBU 125 under-desk mounting kit (part #70-077-01).  
Mount the unit under a desk or table as follows:  
1.  
2.  
If rubber feet were previously installed on the bottom of  
the unit, remove them.  
Secure the under-desk mounting brackets to the  
transceiver with the four machine screws provided in the  
mounting kit (figure 2-3).  
3.  
4.  
Hold the transceiver with attached brackets against the  
underside of the desk or other furniture. Mark the location  
of holes for screws on the desk.  
Drill 1/4" (6.4 mm) deep, 3/32" (2 mm) diameter pilot  
holes in the table or desk at the marked screw locations  
from the underside or inside (the concealed side) of the  
furniture, where the transceiver will be located.  
5.  
Insert the four wood screws into the pilot holes. Fasten  
each screw into the installation surface until just less than  
1/4" of the screw head protrudes.  
FOX HD-SDI • Installation and Operation  
FOX HD-SDI • Installation and Operation  
2-4  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and Operation, cont’d  
c. Tighten the screws.  
Through-desk mounting  
d. Replace the unit inside the surface (step 4).  
The transceiver can be mounted through a desk or other  
furniture using an optional Extron MBD 129 through-desk  
mounting kit, part #70-077-02. Mount the transceiver through a  
desk or table as follows (figure 2-4):  
Projector mounting  
The transceiver can be mounted on a projector bracket using  
either of the following optional Extron projector mounting kits:  
PMK 300 projector mounting kit (part #70-374-01)  
PMK 350 low profile projector mounting kit  
(part #70-563-02 [black] or part #70-563-03 [white])  
PMK 300 mounting  
Mount the transceiver to a PMK 300 bracket as follows:  
1.  
If necessary, remove the feet from the bottom of the  
transceiver.  
2.  
Mount the transceiver to one of the bracket’s three  
mounting plates using two of the supplied 4-40 x 3/16"  
screws in opposite (diagonal) corners to secure the device  
to the bracket. It can be vertically mounted facing either  
up or down (figure 2-5).  
On the side mounting plates, the device is typically  
mounted on the outside of the bracket.  
N
On the front mounting plate, the device is typically  
mounted on the inside of the bracket.  
Figure 2-4 — Through-desk mounting  
Side Mounting  
Plate  
1.  
Loosely attach the mounting brackets to the transceiver  
using the four machine screws and washers supplied with  
the mounting kit.  
Bracket  
Brace  
U-Bolt  
2.  
Hold the transceiver against the inside of the surface  
through which it will be mounted. Mark the four screw  
holes on the inside of the surface to which you are  
mounting the device.  
Extron  
FOX 500 HDSDI  
Transceiver  
Power Supply  
3.  
4.  
5.  
Drill four pilot holes, each 3/32" in diameter by 1/4" deep,  
where you made marks.  
Extron  
PMK 300  
Multi-product Projector Mount Kit  
Using the provided four wood screws, secure the brackets  
to the mounting surface.  
Front Mounting  
Plate  
Slide the transceiver up and down in the mounting  
brackets until the face of the transmitter or receiver is at  
the desired height. Tighten the screws that secure the  
brackets in place.  
If the screws are inaccessible to a screwdriver:  
a. On the transceiver, mark the location of the brackets  
relative to the screws.  
Figure 2-5 — PMK 300 projector mounting a transceiver  
FOX HD-SDI • Installation and Operation  
b. Remove the transceiver from inside the furniture.  
FOX HD-SDI • Installation and Operation  
2-6  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and Operation, cont’d  
3.  
Use the two included tie wraps to strap the power supply  
to one of the brackets.  
PMK 350 mounting  
Mount the transceiver to a PMK 350 bracket as follows:  
The PMK 300 has a hole in the bottom plate that allows the  
projector pole to be inserted through the center of the plate  
(figure 2-6), rather than outside of the plate (figure 2-5).  
To install the PMK 300 in this configuration, slide the  
bracket up from the bottom of the pole before the projector  
is installed on the pole.  
N
1.  
Remove the front and back plates from the PMK 350  
(figure 2-7), using an Extron Tweeker or a #2 Philips  
screwdriver. Retain the screws to reattach the plates when  
you are finished.  
Extron  
Quarter-rack  
Rear Plate  
Sized Product  
Bracket  
Brace  
Contoured  
Base  
L-shaped  
Bracket  
Extron  
PMK 350  
Multi-product Projector  
Mounting Kit  
U-bolt  
Extron  
PMK 300  
U-Bolt  
Multi-product Projector  
Mount Kit  
Extron  
Power Supply  
Front Plate  
Cover Sheet  
Figure 2-7 — PMK 350 projector mounting a  
transceiver  
2.  
3.  
If necessary, remove the feet from the bottom of the  
receiver.  
Secure the transceiver to one side of the mounting tray,  
using two of the supplied 4-40 x 3/16" screws in opposite  
(diagonal) corners.  
Figure 2-6 — Projector pole on the inside  
4.  
5.  
Use the two included tie wraps to strap the power supply  
to the bracket.  
4.  
Place the contoured bracket brace against the pole and  
opposite the back plate. The pole should fit snugly into the  
depression in the center of the bracket brace.  
Place the PMK 350 around the projector ceiling mounting  
pole (figure 2-7, above).  
5.  
Place the U-bolt around the ceiling pole and insert the  
two legs of the U-bolt through the round holes on the  
contoured bracket brace and then through the slotted holes  
on the bracket’s mounting plate.  
The supplied U-bolt fits a typical (1.5" to 2.0" diameter)  
ceiling pole.  
N
6.  
Secure the bracket to the U-bolt with the included hex  
nuts, washers, and lock washers. Tighten the hex nuts just  
enough that they can be loosened by hand.  
FOX HD-SDI • Installation and Operation  
FOX HD-SDI • Installation and Operation  
2-8  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and Operation, cont’d  
6.  
Assemble the U-bolt and the following parts in the  
following order (figure 2-8):  
Connections and Settings  
All connectors are on the rear panel (figure 2-9).  
Mount Plate  
Flange  
FOX HDSDI  
OPTICAL  
POWER  
12V  
Contoured  
Base  
MODE  
0.3A MAX  
U-bolt  
1
2
1
2
HD/SDI IN  
BUFFERED OUTPUTS  
Tx  
Rx  
L-shaped  
Bracket  
5
1
2
3
4
Slotted Hole  
in PMK Tray  
L-shaped  
Bracket Screws  
Figure 2-9 — FOX HD-SDI transceivers connectors  
Ceiling  
Pole  
HD-SDI Input connector — If the FOX HD-SDI is configured  
as either a bidirectional transceiver or as a transmitter, connect  
an HD-SDI, SDI, or 3G-SDI video input to this BNC connector.  
a
b
Figure 2-8 — Hanging the tray on the pole  
Mode switches — Set these DIP switches to the positions shown  
in the table below to select the transceiver configuration. See  
"Transceiver configurations" on page 1-3 for more information.  
a. Pass the legs of the U-bolt through the slotted holes on  
the mount plate flange.  
b. Place the legs around the projector pole.  
SW1 SW2 Mode  
c. Pass the legs through the holes in the contour base.  
Down Down Bidirectional transceiver (default position)  
MODE  
The pole fits snugly into the depression in the center  
of the contoured base.  
N
Down Up  
Transmitter with local monitor outputs  
Down Receiver with daisy chaining  
Up  
Up  
d. Pass the U-bolt legs through the holes in the L-shaped  
1
2
Up  
Spare (functions as receiver with daisy chaining)  
bracket.  
The supplied U-bolt fits a typical (1.5" to 2.0"  
diameter) ceiling pole.  
Fiber optic connectors —  
N
c
This unit outputs continuous invisible light, which  
may be harmful and dangerous to the eyes; use with  
caution. For additional safety, plug the attached  
W
7.  
Align the two slotted holes in the bottom of the L-shaped  
bracket with the two slotted holes in the base of the tray.  
Secure the L-shaped bracket to the base by inserting two  
provided 6-32 x 5/16" screws through the aligned slots.  
dust caps into the optical transceivers  
when the fiber optic cable is unplugged.  
OPTICAL  
8.  
9.  
Move the PMK 350 up to the desired location on the ceiling  
pole, as close to the ceiling as desired.  
Ensure that you use the proper fiber cable for  
your transceivers. Typically, singlemode fiber  
cable has a yellow jacket and multimode fiber  
determine the transceiver's compatibility.  
N
Tx  
Rx  
Secure the L-shaped bracket to the U-bolt using the  
included hex nuts, washers, and lock washers. Tighten the  
hex nuts securely.  
Be sure to tighten the hex nuts securely enough that the  
PMK 350 does not slide down the ceiling pole. A socket  
wrench is recommended to tighten the hex nuts.  
N
Tx In any FOX HD-SDI configuration, for all one-  
way HD-SDI, SDI, or 3G-SDI transmission, connect a  
fiber optic cable to the Optical Tx LC connector.  
10. Secure the front panel to the mounting tray with four of  
the included #6 screws.  
Connect the free end of this fiber optic cable  
to the Optical Rx connector on another  
FOX HD-SDI transceiver that is configured as a  
bidirectional transceiver or as a receiver.  
OPTICAL  
11. If desired, choose one of the provided four sizes of self-  
adhesive cover sheets, and apply it to the underside of the  
mounting tray.  
Tx  
Rx  
FOX HD-SDI • Installation and Operation  
FOX HD-SDI • Installation and Operation  
2-10  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation and Operation, cont’d  
Rx If the FOX HD-SDI is configured as a bidirectional  
Power supply wiring  
transceiver or as a receiver, for one-way communications  
from the transmitting unit, connect a fiber optic cable to the  
Optical Rx connector.  
Figure 2-10 shows how to wire the power connector.  
If the FOX HD-SDI is configured as a bidirectional transceiver,  
connect the free end of this fiber optic cable to the Optical Tx  
connector on the transmitting FOX HD-SDI.  
Smooth  
Ridges  
A
A
SECTION A–A  
If the FOX HD-SDI is configured as a receiver, connect the  
free end of this fiber optic cable to the Optical Tx connector  
on the next FOX HD-SDI in the daisy chain.  
Power Supply  
Output Cord  
Tie Wrap  
Buffered Outputs connectors — In any FOX HD-SDI  
configuration, connect a digital display to these BNC  
connectors. See "Transceiver configurations" on page 1-3 for  
more details.  
3
5
d
e
Captive Screw  
Connector  
If the FOX HD-SDI is configured as a bidirectional transceiver,  
the video is output on both connectors 1 and 2 and is the video  
signal sent from the other transceiver.  
Figure 2-10 — Power connector wiring  
Power supply voltage polarity is critical. Incorrect  
voltage polarity can damage the power supply  
and the FOX HD-SDI. Identify the power cord  
negative lead by the ridges on the side of the cord  
(figure 2-10).  
C
If the FOX HD-SDI is configured as a receiver, the video  
is output on connector 2 only and is the video sent by the  
transmitting unit.  
If the FOX HD-SDI is configured as a transmitter, the video is  
output on both connectors 1 and 2 and is looped through from  
To verify the polarity before connection, plug in the power  
supply with no load and check the output with a voltmeter.  
the same transceiver's HD/SDI Input connector, item  
.
a
Power connector — Plug the included external 12 VDC  
power supply into this 2-pole captive screw connector.  
See “Power supply wiring”, on the next page, to wire the  
connector.  
The two power cord wires must be kept separate  
while the power supply is plugged in. Remove  
power before wiring.  
W
The length of the exposed (stripped) copper wires  
is important. The ideal length is 3/16" (5 mm).  
Longer bare wires can short together. Shorter wires  
are not as secure in the connectors and could be  
pulled out.  
C
Do not tin the power supply leads before installing them  
in the connector. Tinned wires are not as secure in the  
connectors and could be pulled out.  
N
Use the supplied tie-wrap to strap the power cord to the  
extended tail of the connector.  
Alternatively, an optional Extron PS 123 Universal 12 VDC  
Power Supply, part #60-814-01, can power multiple Extron  
12 VDC devices using only one AC power connector.  
FOX HD-SDI • Installation and Operation  
FOX HD-SDI • Installation and Operation  
2-12  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and Operation, cont’d  
Operation  
System operation  
After the transmitting and receiving units and all of their  
Front panel indicators  
connected devices are powered up, the system is fully  
operational. If any problems are encountered, ensure all  
traditional and fiber cables are routed and connected properly.  
All indicators are on the front panel (figure 2-13).  
RATE  
270  
Mbps  
1.485  
Gbps  
2.97  
Gbps  
UNKNOWN  
FOX HDSDI  
1
2
Figure 2-13 — FOX HD-SDI's transceivers indicators  
Power indicator — When lit, this light emitting diode (LED)  
a
b
indicates that the FOX HD-SDI transceiver is receiving power.  
Rate indicators — These LEDs light to indicate the detected  
input video rate, either on the HD/SDI input BNC (if configured  
as a transmitter) or on the Optical Rx connector (if configured as  
a receiver or bidirectional transceiver). The recognized rates are  
270 Mbps, 1.485 Gbps, or 2.97 Gbps.  
When the Rate Unknown LED lights, this indicates that an input  
is detected, either on the HD/SDI input BNC (if configured as  
a transmitter) or on the Optical Rx connector (if configured as a  
receiver or bidirectional transceiver), but that the FOX HD-SDI  
does not recognize the rate.  
All four Rate LEDs blink repeatedly if a fiber optic  
connector module on the rear of the unit is unseated.  
N
The FOX HD-SDI equalizes and distributes the input  
whether it recognizes the rate or not.  
N
Fiber Compatibility Indications  
You must use the proper fiber cable for your transceivers.  
Each transceiver indicates its fiber compatibility, singlemode or  
multimode, at power-up by blinking the four Rate indicators.  
Multimode — The Rate LEDs blink once.  
Singlemode — The Rate LEDs blink twice.  
To determine the fiber cable type, observe the cable jacket.  
Typically, singlemode fiber cable has a yellow jacket and  
multimode fiber cable has an orange jacket.  
N
All transceivers in the system must be the same model (all  
singlemode or all multimode). Mixed transmission mode  
units will not work together.  
N
FOX HD-SDI • Installation and Operation  
FOX HD-SDI • Installation and Operation  
2-14  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation and Operation, cont’d  
FOX HD-SDI  
Appendix A  
A
Reference Information  
Specifications  
Part.Numbers  
FOX HD-SDI • Installation and Operation  
2-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reference Information  
Video  
Specifications  
Signal type...................................... HD-SDI, SDI, and 3G-SDI digital video  
The FOX HD-SDI is a transceiver that can function as a  
N
signals  
transmitter and/or as a receiver. Two units are required for a  
transmitter-receiver system with one fiber optic cable linking  
the two units. The FOX HD-SDI is available in single mode or  
multimode versions.  
Gain ................................................ Unity  
Resolution....................................... 8 or 10 bits, automatic  
Data rates........................................ 270 Mbps, 1.485 Gbps, 2.970 Gbps  
Operation standards..................... SMPTE 259M-C, SMPTE 292M,  
SMPTE 424M, ITU-R BT.601,  
These transceivers are class 1 laser products. They meet the  
safety regulations of IEC-60825, FDA 21, CFR 1040.10, and  
FDA 21 CFR 1040.11.  
N
ITU-R BT.1120, DVB-ASI  
Auto data rate lock........................ Yes  
Video input— transmitter  
Number/signal type..................... 1 single link SDI, HD-SDI, or 3G-SDI  
digital component video  
Optical fiber interconnection between transmitter and  
receiver  
Number/type ................................ 1 fiber optic  
Connectors .................................... 1 female BNC  
Data rates........................................ 19 Mbps to 2.97 Gbps  
Nominal level ................................ 0.8 Vp-p  
Minimum/maximum levels........ 0.5 V to 1 Vp-p with no offset  
Impedance ..................................... 75 ohms  
Return loss ..................................... <-15 dB @ 5 MHz to 2.97 GHz  
DC offset (max. allowable)........... 5 V  
Input coupling............................... AC  
Only one fiber is required to transmit video and embedded audio  
and unidirectional data.  
N
Connectors ..................................... 1 LC connector  
Operating distance........................ 30 km (18.75 miles) with singlemode (SM)  
cables with a FOX HD-SDI SM  
500 m (1640’) with multimode (MM)  
cables with a FOX HD-SDI MM  
Input cable equalization............... Automatic for up to -30 dB of cable loss  
Operating distance is approximate. These are typical  
distances. The maximum distance may be greater than these  
typical numbers depending on factors such as fiber type, fiber  
bandwidth, connector splicing, losses, modal or chromatic  
dispersion, environmental factors, and kinks.  
N
HD-SDI ............................... 120 m (400’) using Extron RG6 cable  
90 m (300’) using Extron RG59 cable  
SDI....................................... 150 m (500’) using Extron RG6 cable  
120 m (400’) using Extron RG59 cable  
The transmission distance varies depending on the signal  
resolution and on the type of cable, graphic card, and display  
used in the system.  
N
Nominal peak wavelength........... 850 nm for FOX HD-SDI MM,  
1310 nm for FOX HD-SDI SM  
Transmission power  
Singlemode......................... -5 dBm, typical  
Multimode.......................... -5 dBm, typical  
Maximum receiver sensitivity  
Singlemode......................... -18 dBm, typical  
Multimode.......................... -12 dBm, typical  
Optical loss budget  
Video output — receiver  
Number/signal type..................... 2 single link SDI, HD-SDI, or 3G-SDI  
digital component video  
Connectors .................................... 2 female BNC  
Reclocking...................................... Automatic for 270 Mbps, 1.485 Gbps,  
2.97 Gbps, or bypassed for unrecognized  
rates  
Singlemode......................... 13 dB, maximum  
Multimode.......................... 7 dB, maximum  
Nominal level ................................ 0.8 Vp-p  
Minimum/maximum levels........ 0.5 V to 1.0 Vp-p  
Impedance ..................................... 75 ohms  
FOX HD-SDI • Reference Information  
FOX HD-SDI • Reference Information  
A-2  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reference Information, cont’d  
Return loss ..................................... <-25 dB @ 100 MHz  
DC offset ........................................ 5 mV with input at 0 offset  
Part Numbers  
FOX HD-SDI part numbers  
General  
The FOX HD-SDI is a transceiver that can function as  
N
External power supply ................ 100 VAC to 240 VAC, 50/60 Hz, 6 watts,  
external; to 12 VDC, 2 A, regulated  
Power input requirements........... 12 VDC, 0.3 A  
Temperature/humidity................ Storage: -40 to +158 °F (-40 to +70 °C) /  
10% to 90%, noncondensing  
a transmitter and/or as a receiver. At least two units are  
required for a transmitter-receiver system with one fiber  
optic cable linking the two units.  
Additional transceivers configured as receivers can be  
added to the system for daisy-chaining.  
Operating: +32 to +122 °F (0 to +50 °C) /  
10% to 90%, noncondensing  
The FOX HD-SDI is available in singlemode (SM) and  
multimode (MM) models:  
Cooling ........................................... Convection, unvented  
Rack mount.................................... Yes, with optional 1U, 9.5” deep rack shelf,  
part #60-190-01 or 60-604-01;  
FOX HD-SDI Models  
FOX HD-SDI SM  
Part number  
60-901-01  
60-900-01  
1U, 6” deep rack shelf, part #60-190-10,  
60-604-10;  
FOX HD-SDI MM  
or VersaTools® 1U, 3” deep rack shelf, part  
#60-190-20 or 60-604-20.  
Included parts  
These items are included in each order for a FOX HD-SDI:  
Also furniture mountable with optional  
Through-Desk Mounting Kit, #70-077-02,  
or Under-Desk Mounting Kit, #70-077-01;  
or attachable to a projector mount using  
optional kit #70-526-02 or 70-077-04.  
Included parts  
Replacement  
part number  
12 VDC power supply  
70-055-01  
Tweeker (small screwdriver)  
User’s guide  
Enclosure type .............................. Metal  
Enclosure dimensions................... 1.0” H x 4.3” W x 3.0” D  
(quarter rack wide)  
(1) 10' LC-LC duplex patch cables  
(SM or MM, depending on the model)  
2.5 cm H x 10.9 cm W x 7.6 cm D  
(Depth excludes connectors.)  
Product weight .............................. 0.5 lb (0.3 kg) per each unit  
Shipping weight ........................... 3 lbs (2 kg) per each unit  
Vibration ........................................ ISTA 1A in carton  
(International Safe Transit Association)  
Listings............................................ UL, CUL  
Compliances................................... CE, FCC Class A, VCCI, AS/NZS, ICES,  
FDA Class 1  
MTBF............................................... 30,000 hours  
Warranty ........................................ 3 years parts and labor  
All nominal levels are at 10%.  
N
N
Specifications are subject to change without notice.  
FOX HD-SDI • Reference Information  
FOX HD-SDI • Reference Information  
A-4  
A-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reference Information, cont’d  
Optional accessories  
Accessories  
Part number  
60-190-01  
RSU 129 9.5" 1U universal rack shelf kit  
RSB 129 9.5" 1U basic rack shelf  
60-604-01  
RSU 126 6" deep 1U universal rack shelf kit  
RSU 126 6" deep 1U universal rack shelf  
60-190-10  
60-604-10  
60-190-20  
RSF 123 3.5" deep 1U VersaTools®  
rack shelf kit  
RSB 123 3.5" deep 1U VersaTools  
rack shelf  
60-604-20  
MBD 129 through desk mounting kit  
PMK 300 projector mounting kit  
70-077-02  
70-374-01  
PMK 350 low profile projector mounting kit,  
black (white)  
70-563-02 (03)  
FOX HD-SDI • Reference Information  
A-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Echo Blower PB 500H User Manual
Eiki Cassette Player 5090A User Manual
Exakta Digital Camera Exa Version 2 User Manual
Fisher Price Motorized Toy Car 73510 User Manual
Fortinet Network Router 127 User Manual
Freestyle Watch 527 User Manual
Friedrich Heat Pump HEAT PUMPS User Manual
Fujitsu Scanner 04ENZ0 User Manual
Fundex Games Board Games Hangman User Manual
GE Refrigerator 197D5226P002 User Manual