User’s Manual
SCP 150, SCP 150 AAP,
and SCP 150 L
Secondary Control Panels for the
System 5 IP Switcher
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500
Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040
Fax +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400
Fax +65.6383.4664
Extron Electronics, Japan
Kyodo Building
16 Ichibancho
Chiyoda-ku, Tokyo 102-0082 Japan
+81.3.3511.7655
Fax +81.3.3511.7656
68-717-01 Rev. A
03 05
© 2005 Extron Electronics. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Chapter 1 • Introduction ..........................................................1-1
About the SCP 150, SCP 150 AAP, and SCP 150 L . 1-2
Features......................................................................................1-2
Chapter 2 • Installation and Operation..........................2-1
Installation Overview .........................................................2-2
Installing or Replacing Button Labels .........................2-2
Mounting Options.................................................................. 2-3
UL Requirements ....................................................................2-4
Preparing the Site .................................................................2-4
Installing the Electrical Box.............................................2-5
Cabling the Rear Panel .......................................................2-6
Pre-installation Testing/Troubleshooting.................. 2-8
Mounting the SCP .................................................................. 2-8
Mounting in a wall box ..........................................................2-8
Mounting in a rack .................................................................2-9
Mounting on a lectern ...........................................................2-9
Front Panel Features..........................................................2-10
Resetting to Factory Firmware Version ...................2-13
Chapter 3 • Remote Communication ...............................3-1
Setting Up RS-232 Communication .............................. 3-2
Using Simple Instruction Set (SIS) Commands .......3-2
Host-to-SCP communications ................................................3-3
SCP-initiated messages ........................................................... 3-3
Error responses ........................................................................ 3-3
Using the command/response tables ....................................3-3
Symbol definitions ................................................................. 3-4
Special Function SIS Commands....................................3-7
Using the Switch/Function Button Table............... 3-10
Switch number locations......................................................3-11
Updating the Firmware ....................................................3-12
Appendix A • Specifications, Part Numbers,
Accessories, and Dimensions............................................... A-1
Specifications ......................................................................... A-2
Included Parts......................................................................... A-3
SCP 150 • Table of Contents
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents, cont’d
Accessories .............................................................................. A-4
Cables ......................................................................................... A-4
Panel Dimensions................................................................. A-5
Templates ................................................................................. A-7
SCP 150
All trademarks mentioned in this manual are the properties of their respective owners.
68-717-01 Rev. A
03 05
Chapter One
1
Introduction
About the SCP 150, SCP 150 AAP, and SCP 150L
Features
SCP 150 • Table of Contents
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
About the SCP 150, SCP 150 AAP, and SCP 150 L
SCP 150
The Extron SCP 150, SCP 150 AAP, and SCP 150 L are hardwired
remote control panels for the Extron System 5 IP switcher. All
models replicate the switcher’s volume, input switching, and
system controls. The SCP 150 AAP also provides four spaces for
the addition of optional architectural adapter plates (AAPs) or
audio, relay, or IR control modules (ACMs, RCMs, IRCMs).
Unless otherwise noted or implied, the term “SCP” refers to all
three models of the SCP 150 (SCP 150, SCP 150 AAP, and
SCP 150 L).
The System 5 IP cannot be configured from the SCP
control panels. All switcher setup must be done from the
switcher or via RS-232. Refer to the System 5 IP
manual for information on setting up the switcher.
The System 5 IP supports up to two SCPs. Up to four control
modules and one IR Link infrared signal repeater can be daisy-
chained with the panels. The SCP accepts signals from the
optional IR 402 remote control.
Chapter Two
The panels can be mounted in or on walls or furniture. The
SCP 150 mounts in a 2-gang electrical box, surface mount box,
or mounting bracket and the SCP 150 AAP mounts in a 4-gang
electrical box, surface mount box, or mounting bracket.
Installation and Operation
2
The SCP 150 L fits into a compact lectern space, into a wall, or
into an Extron UCM RAAP or UCM 10X8P faceplate.
Installation Overview
Installing or Replacing Button Labels
MountingOptions
Features
Gray, black, white, and RAL9010 white faceplates — The SCPs
are available in four colors for integration into a variety
of environments.
ULRequirements
Customizable, illuminated buttons — The panel buttons can be
easily identified, even in low light.
Preparing the Site
System expandability — The panels can be daisy-chained with
Extron’s control modules (IRCMs, ACMs, RCMs) and an
IR Link to provide versatile remote control options.
Installing the Electrical Box
Cabling the Rear Panel
Furniture and wall mountability — The SCPs can be mounted
in or on walls or furniture with the use of optional
electrical boxes, surface mount boxes, or mounting
brackets.
Pre-installationTesting/Troubleshooting
Mounting the SCP
Front Panel Features
Resetting to Factory Firmware Version
SCP 150 • Introduction
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation
3.
Separate the white backing from the clear button cap:
insert the blade of the small screwdriver into the corner
notch and gently twist the blade.
Installation Overview
To install and set up an SCP 150, SCP 150 AAP, or SCP 150L,
follow these steps:
4.
5.
Save the translucent, white backing plate, but remove the
text/label insert from the transparent button cap.
Turn the equipment off. Make sure that the SCP and the
System 5 IP switcher are disconnected from the power
source.
1
Select one of the premade button labels from the label
sheets included with the SCP. Remove the label from its
backing and peel the protective film from the front of the
label, if applicable.
Run cables through the wall or furniture where the SCP
will be installed.
2
3
You may also use a Brother P-Touch label maker to create
custom labels. Cut the labels so they are square, 1/2 inch
on each side.
Prepare the site and install and ground the electrical box,
surface mount box, or mounting brackets.
Set the panel address DIP switch on the back of the SCP.
4
5
6.
Insert the button label into the clear button cap, align the
white backing plate with the cap and firmly snap it into
place.
Wire the 5-pole captive screw connectors on both ends of
the cable that was installed in the wall or furniture in step
2
.
7.
8.
Gently but firmly press the reassembled button into place
in the panel.
Plug the wired connectors into the CM/IR/SCP
connectors on the back of the SCP and on the rear panel of
the switcher.
6
Repeat steps 1 to 7 as needed to relabel other buttons.
Restore power to the switcher.
7
8
Press an input selection button. If the corresponding LED
does not light or the switch to the selected input is not
made, disconnect power from the switcher and verify
correct connector wiring at both ends of the cable.
Use notch to
remove button.
Mount the SCP in the electrical box, surface mount box, or
mounting brackets. Make sure the faceplate is tied to an
earth ground to prevent damage caused by electrostatic
discharge.
9
Clear Button
Align tabs and
Cap
Reconnect the switcher to the A/C power source.
10
lock in place.
TEXT
White Backing
Plate
Installing or Replacing Button Labels
Separate two
You may wish to customize the SCP’s button labels. The labels
can be changed at any time, but it is convenient to change them
before you mount the panel. Follow these steps to change the
translucent button labels:
piece button here.
Mounting Options
Mount the SCP 150 or SCP 150 AAP in an electrical box or
surface mount box or use a mounting bracket to secure it to a
wall, podium, table, or other furniture.
1.
Remove the button from the panel: use a small, flat bladed
screwdriver such as an Extron Tweeker to gently pry a
button out from the panel.
Electrical boxes can be attached to wall studs or to furniture.
Use an electrical box deep enough to contain the SCP’s electrical
components and the connected cables.
2.
Locate the notch in the corner of one side of the clear outer
layer.
SCP 150 • Installation and Operation
2-2
SCP 150 • Installation and Operation
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
To mount the SCP 150 in areas of walls or furniture without
Installing the Electrical Box
studs, use an optional Extron 2-gang mounting bracket, part
#70-086-01, -11, or -21. For the SCP 150 AAP, use an Extron
4-gang mounting bracket, part #70-086-03, -13, or -23.
If you are using a mounting bracket or SMB instead of an
electrical box, follow the mounting instructions that came with
the bracket or SMB.
To mount the SCP 150 externally on a wall or desktop, use an
optional Extron 2-gang SMB surface mount box, part #60-640-02.
For the SCP 150 AAP, use an Extron 4-gang SMB, part
#60-642-02.
To install the electrical box:
1.
Insert the electrical box into the opening, and attach
the wall box to the wall stud (2" x 4") or furniture with
nails or screws, leaving the front edge flush with the
surface, as shown in the following illustration.
UL Requirements
The Underwriters Laboratories (UL) requirements listed below
pertain to the installation of the SCP into a wall or furniture.
Wall Stud
Wall Box
1.
This unit is not to be connected to a centralized DC power
source or used beyond its rated voltage range.
2.
This unit must be installed in a UL listed electrical wall
box.
The UL approved electrical box is not included with the
SCP; the installer is responsible for obtaining and
installing the box.
3.
This unit must be installed in accordance with the
National Electrical Code.
Preparing the Site
Flush with
Wall Surface
To mount the panel using either an electrical box or a mounting
Screws or Nails
bracket, use one of the rough-in templates provided on pages
A-7 through A-9 as a guide to measure and mark the hole in the
wall or furniture through which the SCP will be mounted. The
templates provide measurements for installing the panel with
either an electrical box or a mounting bracket. You do not need
the template if you are mounting the panel using an SMB.
To attach the wall box to wood, use four #8 to #10
wood or sheet metal screws. A minimum of 1/2 inch
(1.25 cm) of screw threads must penetrate the wood.
If the wood is a 2 x 4, such as a wall stud, 10-penny or
larger nails can be used.
The templates are not to scale and are provided for
reference only.
To attach the electrical wall box to metal, use four #8
or #10 sheet metal screws (self-tapping) or #8 or #10
machine bolts with matching nuts.
To prepare the site:
2.
3.
Feed the cables into the wall box. Cable clamps
should be used to hold the cables in place for strain
relief.
1.
2.
3.
Choose a mounting location. If using an electrical box to
wall-mount the panel, locate a stud to which the box will
be attached.
Exposed cable shields (braids or foil) are potential
sources of short circuits. Trim back and/or insulate
shields with heat shrink.
Use the appropriate template and panel dimensions in
Appendix A to as a guide to measure and mark the area to
cut out of the wall or furniture.
Cut out the opening in the wall or furniture.
SCP 150 • Installation and Operation
2-4
SCP 150 • Installation and Operation
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
Cabling the Rear Panel
Serial/host port — Use this 3-pole captive screw connector to
connect to your PC’s RS-232 port. Extron Simple Instruction Set
(SIS) commands can then be issued from the PC to monitor and
obtain information from the SCP. This port is also used for
uploading firmware to the SCP, if necessary. Refer to chapter 3,
Remote Communication, for further details.
3
Do not connect to this port if the SCP is being used with
the System 5IP.
2
3
A
B
C
D
E
2
3 1
4
J5
1
O N
IR Link
Panel address DIP switch — If using two SCPs, set DIP
switch 1 to assign a unique address to each panel. Set the
switch to Off to assign address 00 and On to assign address 01.
Switches 2 and 3 are not used.
1
A
+12VDC
B Ground (
)
D
IR Link
The System 5 IP can support up to two SCPs.
The panels must each have a unique address.
DIP switch 4 is used to enable the RS-232/host port of
the SCP 150. Note: If the SCP is connected to the
System 5IP, set switch 4 to the “off” position.
IRCM-DV+
Control Module
A
B
C
D
E
A
B
C
D
E
SIGNAL
IR LINK
IR Link
CM/IR/SCP connectors — These two 5-pole captive screw
connectors function in exactly the same way and can be used
interchangeably. Connect one connector to a System 5 IP
switcher and the other to a second SCP, an Extron control
module (ACM, RCM, IRCM), or an Extron IR Link infrared
signal repeater.
2
DVD CONTROL
MENU
Tx
TITLE
ENTER
A
B
C
D
A
B
C
D
E
+12VDC
Ground (
Control signal (IRCM)
Modulated IR (IR Link)
+12VDC
Ground (
Control signal (IRCM)
Modulated IR (IR Link)
SCP Communication (IR)
A
B
C
D
A
B
C
D
E
REW
PLAY
NEXT PAUSE
STOP
)
Control
Module
)
Two SCPs, up to four control modules, and one IR Link can be
daisy-chained using these connectors. The maximum distance
between the System 5 IP and a connected device is 200' (61 m).
The switcher provides 12 VDC power to the SCP and any daisy-
chained control devices via these connectors, so no additional
power supply is required.
VOLUME
PROJECTOR
PROJECTOR
ON
PROJECTOR
OFF
FUNCTION
BUTTON
LIGHTS
ON
LIGHTS
OFF
IR
PC
INPUT
1
INPUT
INPUT
3
INPUT
4
INPUT
5
2
3 1
4
2
J5
O N
SCP 150
SCP 150
System 5 IP
Rear Port
SCP 150
Wire the connectors as shown in the illustration on the next
page. The illustration is a guide; the SCPs, control modules, and
IR Link can be daisy-chained in combinations other than the one
shown.
SCP 150 • Installation and Operation
2-6
SCP 150 • Installation and Operation
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
Mounting in a rack
Pre-installation Testing/Troubleshooting
The SCP 150 L is rack-mountable using the full rack width
Before mounting the SCP to the wall or furniture, test the
system to make sure that the connections are correct and the
panel is working correctly. Test the system by powering on the
switcher, then pressing the input selection buttons on the
SCP and watching the LEDs on the switcher to see if the system
switches to the desired inputs.
UCM-RAAP mounting plate. Mount the UCM-RAAP using the
rack mounting screws included with the monting plate. Next,
mount the SCP 150 L to the UCM-RAAP using the SCP’s four
mounting screws, as show in the following diagram.
The connections between the SCP and a System 5 IP
equipped with front panel controls can be tested even if
input/output devices are not available. For a
System 5 IP without front panels controls, input 5 will
be the only input available to view.
Extron
UCM-RAAP
Mounting the SCP
Once the system has been cabled and tested, the SCP can be
mounted to the wall or furniture. See Mounting Options, earlier
in this chapter, for a description of the available brackets and
boxes in which the SCP may be mounted.
Extron
SCP 150 L
R
O
T
C
E
J
N
N
O
O
O
I
R
T
T
C
P
N
U
F
T
U
R
B
O
T
C
F
E
J
O
O
R
P
F
R
O
T
C
N
E
J
O
E
R
P
M
O
LU
O
V
C
P
S
T
H
IG
L
FF
O
S
T
N
H
O
IG
L
T
U
P
L
IN
0
5
1
5
IR
P
C
T
U
S
P
IN
4
T
U
P
IN
3
T
PU
2
IN
T
PU
IN
1
n
o
r
t
x
E
Mounting in a wall box
1.
With power removed, insert the SCP into the wall,
furniture, or SMB.
Mounting on a lectern
2.
Secure it to the box or mounting bracket with the
provided machine screws. The following illustration shows
an SCP mounted in an electrical box.
The SCP 150 L is designed to be mounted on a lectern. To
mount the SCP 150 L, cut a hole of the required size (see
“Preparing the Site” in this chapter) and attach the SCP 150 L
using the provided wood screws.
If you are not installing the SCP into a grounded metal
electrical box, make sure that the faceplate is grounded to
an earth ground.
Lectern
Extron
SCP 150 L
R
O
T
C
E
N
J
IO
O
T
C
R
N
P
U
N
F
O
T
T
R
U
O
B
T
C
E
J
O
R
P
FF
O
R
O
T
C
E
J
O
E
R
P
N
M
O
U
L
PC
O
V
S
HT
LIG
FF
O
S
T
LIGH
T
N
U
5
SCP 150
O
INP
PUT
4
IN
T
INPU
3
T
PU
2
IN
T
U
1
INP
OR
OJECT
N
IO
N
T
T
C
PR
N
U
F
O
T
R
U
O
T
F
B
C
F
E
O
J
O
R
P
R
O
T
C
E
O
J
O
R
P
UME
N
L
VO
C
P
S
T
F
H
IG
L
F
O
S
T
N
H
O
IG
L
T
U
5
P
N
I
T
U
P
N
I
4
T
U
P
N
I
3
T
U
2
P
150
IN
CP
S
T
U
1
P
IN
SCP 150 • Installation and Operation
2-9
2-8
SCP 150 • Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
Front Panel Features
1
2
6
The controls on the SCP 150, SCP 150 AAP, and SCP 150 L
replicate the System 5 IP’s volume, input switching, and system
controls. All the button functions for the System 5 IP and the
SCPs are configured via RS-232 or Ethernet control. See the
System 5 IP user’s manual for instructions on configuring the
buttons.
PROJECTOR
VOLUME
PROJECTOR
PROJECTOR
OFF
FUNCTION
BUTTON
ON
LIGHTS
ON
LIGHTS
OFF
PC
IR
3
5
1
2
6
INPUT
1
INPUT
3
INPUT
5
INPUT
2
INPUT
4
Extron
PROJECTOR
VOLUME
PROJECTOR
ON
PROJECTOR
OFF
FUNCTION
BUTTON
4
LIGHTS
ON
LIGHTS
OFF
IR
PC
3
5
SCP 150 L
INPUT
1
INPUT
2
INPUT
3
INPUT
4
INPUT
5
All the buttons on the SCP can light bright green, red,
or amber when selected in stand-alone mode (not
connected to the System 5 IP). Unselected buttons light
dim amber.
SCP 150
On and Off buttons — Press these buttons to turn the projector
on and off. The buttons flash during the projector’s warm up
or cool down cycle, and then light steadily.
1
4
SCP150
and
Function buttons — These buttons are fully configurable and
can be used to control the System 5 IP’s relays, execute IR or
RS-232 commands, or trigger other buttons. Refer to the
System 5 IP user’s manual for information on configuring these
buttons.
2
3
1
2
7
6
PROJECTOR
VOLUME
3
The three function buttons in the middle row ( ) replicate the
PROJECTOR
PROJECTOR
OFF
FUNCTION
BUTTON
ON
three function buttons on a System 5 IP equipped with front
panel controls. The single function button in the top row (
an additional function button not found on the switcher.
2
) is
LIGHTS
ON
LIGHTS
OFF
IR
PC
5
3
Input selection buttons — These buttons replicate the five input
selection buttons on a System 5 IP equipped with front panel
controls. Press one of these buttons to select an input on the
switcher. Refer to the System 5 IP user’s manual for more
information on input selection.
4
5
INPUT
1
INPUT
2
INPUT
3
INPUT
4
INPUT
5
SCP 150 AAP
IR signal pickup sensor — This sensor allows control of the SCP
using an optional Extron IR 402 remote control. Point the
remote directly at the sensor. The remote has a range of
4
SCP150AAP
SCP 150 • Installation and Operation
2-10
2-11
SCP 150 • Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
approximately 30 feet (9.14 meters) within 40 degrees on either
side of the axis. See the following illustration.
Resetting to Factory Firmware version
To reset the SCP to the firmware version with which it was
delivered from the factory, press and hold the buttons
numbered 1 and 3 on the front panel while applying power to
the unit. See the following three illustrations.
PROJECTOR
VOLUME
PROJECTOR
ON
PROJECTOR
OFF
FUNCTION
BUTTON
LIGHTS
ON
LIGHTS
OFF
PC
IR
INPUT
1
INPUT
3
INPUT
5
INPUT
2
INPUT
4
Extron
PROJECTOR
VOLUME
SCP 150 L
40
40
IR
30 feet
maximum
SCP 150
To reset, press these two buttons
simultaneously while applying power
to the SCP 150.
IR 402 Remote
ResettingtheSCP150tofactorydefaults
Volume knob and indicator LEDs — Turn this knob to adjust
the volume on the input that is currently selected. The five
LEDs indicate the current volume level, as shown in the
following illustration. The top LED is red and the others are
green.
6
PROJECTOR
VOLUME
IR
VOLUME
VOLUME
VOLUME
LED Off
LED Blinking
LED On
1-19%
0% (Min) or Mute
VOLUME
20-39%
VOLUME
VOLUME
SCP 150 AAP
To reset, press these two buttons
simultaneously while applying power
to the SCP 150 AAP.
40-59%
60-89%
90-100% (Max)
AAP mounting spaces (SCP 150 AAP only) — Mount up to four
single-space AAPs or control modules (IRCMs, ACMs, RCMs)
here.
7
ResettingtheSCP150AAPtofactorydefaults
2-12
SCP 150 • Installation and Operation
2-13
SCP 150 • Installation and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
SCP 150
PROJECTOR
VOLUME
IR
Extron
To reset, press these two buttons
simultaneously while applying power
to the SCP 150L.
Chapter Three
3
Resetting the SCP 150 L to factory defaults
Remote Communication
Setting Up RS-232 Communication
Using Simple Instruction Set (SIS) Commands
Special Function SIS Commands
Using the Switch/Function Button Table
Updating the Firmware
SCP 150 • Installation and Operation
2-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication
Host-to-SCP communications
Setting Up RS-232 Communication
SIS commands consist of one or more characters per field. No
special characters are required to begin or end a command
sequence. When the SCP determines that a command is valid, it
executes the command and sends a response to the host device.
The RS-232 interface allows you to obtain information about the
SCP and to activate certain SCP functions from a host computer
or other device (such as a control system) attached to the rear
panel RS-232 port (shown below).
Most responses from the panel to the host end with a carriage
return and a line feed (CR/LF = ), which signals the end of
the response character string. A string is one or more
characters.
Tx
Gnd Rx
J1
SCP-initiated messages
3-polecaptivescrewconnectorfortheRS-232port
on the SCP rear panel
At power-up, the following SCP-initiated message appears:
© Copyright 2004, Extron Electronics, SCP 150, Vx.xx
This message is displayed only at power-up.
Use the following protocol settings for your PC:
Baud rate: 9600
Data bits: 8
Parity: None
When a local event such as a front panel selection takes place,
the SCP responds by sending a message to the host indicating
what selection was entered (see Switch responses on page 3-5).
Stop Bits: 1
Flow Control: None
No response to these messages is required from the host.
The control device (host) can use the Extron Simple Instruction
Set™ (SIS™) commands.
Error responses
When the SCP receives a valid SIS command, it executes the
command and sends a response to the host device. If the SCP is
unable to execute the command because the command is invalid
or contains invalid parameters, the SCP returns an error response
to the host.
In order to use the RS-232 port, DIP switch 4 must be
set to the “on” position.
Using Simple Instruction Set (SIS) Commands
Error response codes and their descriptions are shown below.
Each error response is followed by a carriage return.
SIS commands can be used with the SCP only when it is in
stand-alone mode; that is, DIP switch #4 on the rear panel is in
the ON position. The available commands enable you to test
the front panel LEDs and buttons, and to query for certain
information about the SCP.
E10 – Invalid command
E13 – Invalid command parameter
E23 – Bad checksum
E28 – Bad filename/File not found
You cannot program any SCP buttons or switches using
SIS commands. The SCP’s buttons only reflect what is
programmed for the System 5 IP to which the SCP is
connected.
Using the command/response tables
The command/response tables on the following pages list valid
command ASCII codes, the SCP’s responses to the host, and a
description of the command’s function or the results of
executing the command.
The ASCII to HEX conversion table on the next page is for use
with the command/response tables.
SCP 150 • Operation
3-2
SCP 150 • Operation
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication, cont’d
ASCII to HEX Conversion Table
•
ASCII to Hex conversion table
Symbol definitions
= CR/LF (carriage return/line feed) (hex 0D 0A)
= Soft carriage return (no line feed)
= Escape key
Esc
= Space
•
X1
= Firmware number
If a command is not case-sensitive, this is indicated by
showing the command letter in uppercase. followed by a
slash (/), then the same letter in lowercase.
Examples: Q/q, I/i
SCP 150 • Remote Communication
3-4
SCP 150 • Remote Communication
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication, cont’d
Special Function SIS Commands
X?
Y?
The syntax for setting a special function for an SCP 150 is
*
* __ #,
X?
Y?
where
is the value of the action to be performed,
is the value for
the button or switch, and __ is the function number. To view a
function’s setting, use __#, where __ is the function number. In the
X?
Y?
following table the values of the
and
variables are different for
each command/function. These values are given in the rightmost
column.
SCP 150 • Remote Communication
3-6
SCP 150 • Remote Communication
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication, cont’d
SCP 150 • Remote Communication
3-8
SCP 150 • Remote Communication
3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication, cont’d
Switch number locations
Using the Switch/Function Button Table
The following illustration shows the button/switch memory
block numbering on the SCP 150 front panel. Refer to the
Switch/Button table, on the previous page. The switch locations
are the same on the SCP 150 AAP and SCP 150 L models.
Switches are assigned to specific buttons on the SCP, any
attached remote control module (IRCM/RCM/ACM), or the
IR 402 remote. Each time a button is pressed or released, or a
knob is turned on the SCP or a control module, the switch
number associated with that button appears on your PC
terminal emulator screen (HyperTerminal, etc.) as part of the
host response.
On most of the special function SIS commands, the switch
PROJECTOR
VOLUME
number is the
value that you enter as part of the command.
X?
Switch Switch Switch
(See the Command/response table for special function SIS commands,
#1
#2
#8
earlier in this chapter.)
Switch Switch Switch
#5 #6 #7
The following Switch/Function Button table shows which switch
number is associated with each button or knob on the SCP,
control module, or IR 402. In the Switch column, locate the
switch number displayed on your terminal emulator, then look
in the Function Button column beside the number to find out
which button was pressed or released.
IR
Switch Switch Switch Switch Switch
#9 #10 #11 #12 #13
SCP 150
The SCP does not use all of the available buttons/
switches.
No buttons can be programmed via the SCP.
Switch
Function Button
1
2
Power on
Power off
5
6
7
8
Function 1 (room) button
Function 2 (room) button
Function 3 (room) button
Function 4 (room) button
Input 1 selection button
Input 2 selection button
Input 3 selection button
Input 4 selection button
Input 5 selection button
9
10
11
12
13
Switch/FunctionButtontable
SCP 150 • Remote Communication
3-10
SCP 150 • Remote Communication
3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication, cont’d
Updating Firmware
4.
5.
Power on the SCP. See the
previous caution.
If necessary, you can replace the SCP’s firmware without
On your PC, start the Firmware
Loader program. The screen on
the right appears:
changing firmware chips. This procedure must be performed
using a PC on which the Firmware Loader Software has been
installed. The PC’s RS-232 port must be directly cabled to the
SCP’s RS-232 port.
6.
7.
Select the COM port through
which the PC will communicate
with the SCP via RS-232.
CAUTION
Do not attempt to upload firmware if a System 5 IP
is connected to the SCP with any connections other
than power. The RS-232 cable from the PC must be
connected directly to the SCP.
If the baud rate is not set to 9600,
do the following:
a.
Click the Baud button. A baud rate pop-up menu
appears, and the Baud button changes to OK.
System 5 IP
Rear Panel
CM/IR/SCP
A
B
C
D
E
+V
G
CM IR SCP
A
B
C
D
E
+12VDC
Ground (
A
B
)
Power From
System 5 IP
b.
From the pop-up menu, select 9600.
8.
Click the OK button that was originally the Baud button
(circled in the figure above). The following window opens,
indicating the current firmware version.
2
3 1
4
J5
G
Rx Tx
O N
RxTx
SCP 150
Rear Panel
Transmit (Tx)
Receive (Rx)
Ground (Gnd,
RS-232 to/from Host PC
)
Each time that the existing firmware is replaced, the SCP
is reset to the factory default settings.
Follow the directions below.
1.
appropriate firmware file for the model of SCP that you
want to update. Save the new firmware file to your PC,
and write down its filename and save location for later use.
9.
Click Upload. You are prompted to select the firmware file
that you downloaded in step 1. Click OK.
10. When the browser window opens, locate and select the
firmware file, then click Open to upload the firmware to
the SCP.
2.
3.
Connect a cable between the SCP’s RS-232 port and the
serial (RS-232) port of the PC (see chapter 2).
Set DIP switch 4 to the ON position.
SCP 150 • Remote Communication
3-12
SCP 150 • Remote Communication
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Communication, cont’d
The firmware update file must have a filename extension
of .bin. If the file does not have that extension, it will not
SCP 150
work properly.
Appendix A
11. Follow the instructions on the screen to upload the
firmware.
12. When the firmware uploading is complete, the following
A
dialog box appears:
Specifications, Part Numbers,
Accessories, and Dimensions
Specifications
Included Parts
Accessories
Click OK to exit the Firmware Upload program.
Cables
PanelDimensions
Templates
SCP 150 • Remote Communication
3-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications, Parts, Accessories, Dimensions
All nominal levels are at 10%.
Control/remote — control pad
Serial control port ........................ RS-232, via a 3.5 mm captive screw
connector, 3 pole
Specificationsaresubjecttochangewithoutnotice.
Baud rate and protocol ............... 9600 baud, 8 data bits, 1 stop bit, no parity
Serial control pin configurations A = TX, B = RX, C = GND
IR remote control ........................ IR 402 (optional)
30' maximum, 40 degrees off axis
Program control .......................... Extron’s Simple Instruction Set (SIS™)
Included Parts
These items are included in each order for an SCP 150,
SCP 150 AAP, or SCP 150 L:
General
Power ............................................ 12 VDC, at 0.5 A, from the System 5 IP
switcher
Temperature/humidity .............. Storage: -40 to +158 °F (-40 to +70 °C) /
10% to 90%, noncondensing
Replacement
part number
Included parts
SCP 150 (controller only - no faceplate)
60-495-00
Operating: +32 to +122 °F (0 to +50 °C) /
10% to 90%, noncondensing
Rack mount .................................. No, but furniture/wall mountable with
included faceplates and electrical boxes or
optional mounting bracket kits or AAP wall
plates.
or
or
SCP 150 (gray, black, white, RAL9010) 60-495-01, -02, -03, -05
SCP 150 AAP (gray, black, white, RAL9010)
60-496-01, -02, -03, -05
or
SCP 150 L (black, white, RAL 9010)
3.5 mm, 5-pole captive screw connector (2)
3.5 mm, 3-pole captive screw connector (1)
Button labels (text)
60-495-32, -33, -35
10-319-01
Enclosure type .............................. Metal
Enclosure dimensions
10-265-03
33-954-01
SCP 150 faceplate ............. 4.5" H x 4.6" W x 0.1" D (2 gang)
11.4 cm H x 11.7 cm W x 0.3 cm D
Button labels (symbols)
33-955-01
SCP 150 AAP faceplate .... 4.5" H x 8.25" W x 0.1"D (4 gang)
11.4 cm H x 11.7 cm W x 0.3 cm D
SCP 150 L faceplate .......... 3.2" H x 6.5" W x 0.1"D
8.0 cm H x 16.5 cm W x 0.3 cm D
Circuit board (all models) 2.9" H x 3.5" W x 0.5" D
7.4 cm H x 8.9 cm W x 1.3 cm D
International faceplate labels
(gray, black, white)
33-953-01, -02, -03
Tweeker (small screwdriver)
SCP 150 User’s Manual
[Allow at least 1.5" (3.8 cm) depth in the
wall or furniture. Depth excludes
connectors, knob, and buttons.]
Product weight ............................. 0.3 lbs (0.1 kg)
Shipping weight ........................... 2 lbs (1 kg)
Vibration ....................................... ISTA 1A in carton (International Safe
TransitAssociation)
Listings .......................................... UL, CUL as a component of the System 5 IP
Compliances ................................. CE as a component of the System 5 IP
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
SCP 150 • Specifications, Parts, Accessories, Dimensions
A-2
SCP 150 • Specifications, Parts, Accessories, Dimensions
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications, Parts, Accessories, Dimensions, cont’d
Accessories
Panel Dimensions
Ø.520 THRU
These items may be ordered separately:
5X Ø.125 THRU
4X Ø.160 THRU
wØ.290 82°
(CODED "E")
SCP 150
wØ.180
X
90°
X
FAR SIDE
R. 070 TOP
EDGE ALL
AROUND.
Accessories
Part number
4.500
2-gang mounting bracket (gray, black, white, RAL9010)
70-086-01, -11, -21, -25
2X 3.858
3.505
3.390
3.305
2X 3.105
2.905
3.195
4-gang mounting bracket (gray, black, white, RAL 9010)
70-086-03, -13, -23, -25
2.705
2.375
2.330
SEE DETAIL "B"
Ø.219 THRU
wØ.392 82°
NEAR SIDE
x
2-gang SMB surface mount box
4-gang SMB surface mount box
Button labels (international text)
IR 402 remote control
60-640-02
60-642-02
33-956-01
70-207-01
1.563
2X 1.000
2X .576
3X Ø.120 THRU
wØ.220
(CODED 'F')
X
82°
.000
(.10 THK.)
4X R.25
SCP 150 AAP
Cables
4X Ø.160 THRU
Ø.290 82°
(CODED E)
w
X
SEE DETAIL "A"
R.070 TOP
EDGE ALL
AROUND
These cables may be ordered separately:
Ø.520 THRU
4.500
SEE DETAIL "C"
Comm-Link cable
Part number
5X Ø.125 THRU
wØ.180 90°
FAR SIDE
X
2X 3.858
3.505
50 feet/15.2 meters long
26-461-01
26-461-02
26-461-03
26-461-04
22-119-02
22-119-03
3.390
3.305
3.195
2X 3.105
2.905
100 feet/30.5 meters long
200 feet/61 meters long
2.705
2.375
2.330
2.200
Ø.219 THRU
wØ.392 82°
X
NEAR SIDE
1.563
400 feet/122 meters long
Bulk 500 feet/152.4 meters long
Bulk 1000 feet/304.8 meters long
2X 1.000
2X .576
.000
(.10 THK)
4X R.25
3X Ø.120 THRU
wØ.220 82°
(CODED 'F')
SEE DETAIL "B"
x
1.880
3.110
.940
1.555
.320
.640
.640
.320
DETAIL `A'
DETAIL `B'
3.520
+.010-.000
1.760
8X Ø.170 THRU
4x R.050
2.740
1.370
1.405
1.375
1.050
2.100
.700
2.750
2.810
+0.015-0.000
.350
1.500
3.000
DETAIL `C'
A-4
SCP 150 • Specifications, Parts, Accessories, Dimensions
SCP 150 • Specifications, Parts, Accessories, Dimensions
A-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications, Parts, Accessories, Dimensions, cont’d
SCP 150 L
Templates
The templates are not to scale and are provided for
reference only.
6 . 5 0 0
2 X 6 . 2 5 0
Top Panel
3.6"
(9.15
cm)
Electrical Box
4 . 8 7 5
SURFACE CUT-OUT AREA
FOR FURNITURE MOUNT
2.8"
(7.1 cm)
Location of SCP 150
2 . 7 5 5
2 . 2 5 0
To install SCP 150
directly into furniture,
cut along this line.
1 . 6 2 5
SCP 150
TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's SCP 150
2 X . 2 5 0
. 0 0 0
A-6
SCP 150 • Specifications, Parts, Accessories, Dimensions
SCP 150 • Specifications, Parts, Accessories, Dimensions
A-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications, Parts, Accessories, Dimensions, cont’d
3.15"
(8.0cm)
Top Panel
2.85"
(7.2 cm)
SURFACE CUT-OUT AREA
FOR FURNITURE MOUNT
6.5"
(16.5 cm)
3.6"
(9.15 cm)
Location of SCP 150
To install SCP 150
directly into furniture,
cut along this line.
SCP 150 L
TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's SCM-150L
A-8
SCP 150 • Specifications, Parts, Accessories, Dimensions
SCP 150 • Specifications, Parts, Accessories, Dimensions
A-9
Download from Www.Somanuals.com. All Manuals Search And Download.
|