OWNER’S MANUAL
Model HV118H
120V., 60Hz., 8.33 Amps
Mini Canister with Caddy
For information or assistance:
EURO-PRO Operating LLC
94 Main Mill Street, Door 16
Plattsburgh, NY 12901
Tel: (800) 798-7398
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLE SHOOTING GUIDE
IMPORTANT SAFETY INSTRUCTIONS
When using your Mini Canister vacuum, basic safety precautions should always
be observed, including the following:
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
1.
2.
Plug unit in firmly.
Check fuse or breaker. Replace
fuse/reset breaker.
WARNING: To reduce the risk of fire,
electrical shock, or injury:
1.
Power cord not firmly plugged into
outlet.
12. Do not pick up hard or sharp objects
such as glass, nails, screws, coins, etc.
13. Do not use without all filters in place.
14. Turn off all controls before plugging or
unplugging vacuum cleaner.
15. Use extra care when vacuuming on
stairs.
16. Do not pick up flammable or
combustible materials (lighter fluid,
gasoline, kerosene, etc.) or use in the
presence of explosive liquids or vapor.
17. Do not pick up toxic material (chlorine
bleach, ammonia, drain cleaner, etc.).
18. Do not use in an enclosed space filled
with vapors given off by oil based
paints, paint thinner, moth proofing
substances, flammable dust, or other
explosive or toxic vapors.
19. Always unplug this appliance before
connecting or disconnecting vacuum
hose.
20. Use only on dry, indoor surfaces.
21. Do not use for any purpose other than
described in this user’s guide.
22. Use only extension cords UL-rated or
cUL at 15 amperes. extension cords
rated for less amperage may overheat.
Care should be taken to arrange the
cord so that the cord cannot be pulled
or tripped over.
VACUUM WILL
NOT OPERATE
1. Do not leave vacuum cleaner unattended
when it is plugged in. Unplug from
outlet when not in use and before cleaning
or servicing.
2. To reduce the risk of electric shock – do
not use outdoors or on wet surfaces.
3. Do not allow children to use as a toy.
Close attention is necessary when used
by or near children.
2.
3.
4.
No power in wall outlet.
Needs servicing.
Thermostat has tripped.
3.
4.
Call 1-800-798-7398.
Turn the unit off and unplug from
outlet. Allow unit to cool down,
then restart.
1.
2.
Empty and clean dust cup.
Turn unit off and unplug from
wall outlet. Remove Dust Cup
Filter and check for object(s) in
air duct and remove.
1.
2.
3.
Dust cup is full.
Unit clogged.
Dust Cup Filter needs cleaning or
replacing.
VACUUM WILL
NOT PICK-UP OR
SUCTION POWER
IS WEAK
3.
4.
Clean or replace Dust Cup
Filter.
Turn unit off and unplug from
wall outlet. Check for objects in
deluxe hose/extension tube.
4. Use only as described in this manual. Use
only manufacturer’s recommended
attachments.
4.
Flexible Hose/Extension Tubes
clogged
5. Do not use with damaged cord or plug. Do
not use vacuum cleaner if it has been
dropped, damaged, left outdoors, or
dropped into water. Return appliance to
EURO-PRO Operating LLC. for
examination, repair or adjustment.
6. Do not pull or carry by cord. Do not use
cord as a handle, close a door on cord,
or pull cord around sharp edges or
corners. Do not run appliance over cord.
Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To
unplug, grasp the plug, not the power
cord.
8. Do not handle plug or vacuum cleaner
with wet hands. Do not use outdoors or
on wet surfaces.
9. Do not put any objects into openings. Do
not use with any opening blocked and
do not restrict airflow. Keep all openings
free of dust, lint, hair, and anything that
may reduce airflow.
1.
2.
Dust cup full.
Rotating brush or elbow
obstructed.
Belt broken.
Hose obstructed.
Dust cup filter clogged.
TURBO BRUSH
DOES NOT
ROTATE OR
ROTATES
1.
2.
3.
4.
5.
Empty and clean dust cup.
Clear obstructions.
Call 1-800-798-7398.
Clear obstruction.
3.
4.
5.
SLOWLY
Clean or replace dust cup filter.
1.
2.
Dust cup is full.
Dust Cup Filter is not installed
correctly.
There is a puncture/hole in Dust
Cup Filter.
1.
2.
Empty and clean dust cup.
Review Dust Cup Filter
instructions.
DUST ESCAPING
FROM VACUUM
3.
3.
1.
Replace Dust cup filter.
Remove hose and/or brushes.
Remove obstruction from hose
and /or brush.
VACUUM, HOSE
OR BRUSHES
WILL NOT PICK-UP
1.
2.
Hose clogged.
Dust cup is full.
2.
Empty and clean dust cup.
23. Store your appliance indoors in a cool,
dry area.
24. Keep your work area well lit.
25. Do not immerse the mini canister into
water or other liquids.
26. Keep end of hose, wands and other
openings away from your face and
body.
FOR REPLACEMENT FILTER INFORMATION
or for Technical Support
10. Keep hair, loose clothing, fingers and all
parts of body away from openings and
moving parts.
for Model HV118H
Call Customer Service:
1 - 800 -798-7398
11. Do not pick up hot coals, cigarette butts,
matches or any hot, smoking, or burning
objects.
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Please Note:
The HEPA Dust Cup Filter is washable. It should, however, be replaced every six (6)
months to ensure peak performance of your vacuum.
The Exhaust Filter is washable. It should however be replaced every three (3) months
to ensure peak performance of your vacuum.
SAVE THESE INSTRUCTIONS
For Household Use Only
Important:
Make sure that ALL filters are completely dry (air dry only for 24 hours) before re-
installing back in the mini canister vacuum.
WARNING: To reduce the risk of electric shock, this appliance has a
polarized plug (one blade is wider than the other). This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install
the proper outlet. Do not modify the plug in any way.
Rev. 08/03D
8
1
Download from Www.Somanuals.com. All Manuals Search And Download.
PRECAUTIONARY MEASURES
OPERATING INSTRUCTIONS
CAUTION: The suction hole must be
5. Vigorously “TapClean”
the HEPA Dust Cup
Filter on a hard
Important: If the suction opening in the unit, the hose or the extension tubes
become blocked, switch off the vacuum cleaner and remove the blocking
substance before you start the unit again.
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
surface until no more
dust is observed
falling out from
Intelli-Sense Filter MonitorTM
When the Intelli-Sense Filter MonitorTM
lights up, it means that the dust cup is full
or filter needs cleaning. You must empty
the dust from the dust cup and clean the
HEPA dust cup filter right away.
5. When pulling out the power plug
from the wall outlet, pull the plug
not the power cord.
1. Do not operate the vacuum
cleaner to close too heaters,
or radiators.
between the pleats of
the filter.
6. “TapClean” the Debris
Screen or rinse under
a faucet until clean.
Remember that the
Changing & Cleaning the Exhaust
Filter
The exhaust filter is a washable filter but
should be replaced every three (3)
months depending on usage.
1. Remove the exhaust filter cover from
the rear of the unit.
2. Rinse the exhaust filter in
lukewarm water and dry the
filter completely. Do not use
a washing machine to rinse
the filter. Do not use a
Debris Screen must be
completely air dried for
24 hours before
Debris
reinstalling in the vacuum.
Screen
7. To re-assemble the HEPA filter
assembly, first insert the HEPA
filter onto the dust cup cover
6. Do not pick up anything that is
burning or smoking such as
making sure to push it all the way
in. Then insert the debris screen
again making sure that it is pushed
all the way up against the dust cup
cover.
cigarettes, matches or hot ashes.
2. Before inserting the power plug
into the wall outlet, make sure that
your hands are dry.
7. Do not use without dust cup filter or
exhaust filter in place.
hair dryer to dry it. Air dry
8. When replacing the dust cup cover
with the HEPA filter assembly
into the dust cup, make sure that
the tab on the
ONLY for 24 hours. Never
operate the vacuum without
the exhaust filter in place.
8. Before you start vacuuming,
make sure to remove large or
sharp objects that might
3. When the filter is dry, replace
into the unit and replace the exhaust
filter cover over it.
4. A severely soiled or clogged filter
should be thoroughly washed with
fresh tepid water. A mild detergent
can be used if required.
dust cup cover
damage the vacuum.
is fully aligned
with the tab
3. Do not vacuum any liquids.
indentation on
the dust cup
4. Keep hair, loose clothing, fingers,
feet and all parts of body away from
openings.
handle otherwise
the seal will not
be complete
and the unit will not
function properly.
Motor Thermostat
IMPORTANT: This unit is equipped
with a motor protective thermostat. If for
some reason the vacuum cleaner should
overheat, the thermostat will
automatically turn the unit off. Should
this occur:
• Push the On/Off button once.
• Disconnect the plug from the power
source.
• Check the source of overheating
problem. (i.e. clogged hose or filter)
• If clogged hose or filter is found, unclog
the hose and replace the filter.
• Wait at least 45 minutes before
attempting to reuse the vacuum.
• After unit has cooled down for 45
minutes, plug in the cleaner and push
the On/Off button. The vacuum should
start again.
PLEASE NOTE: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Dust Cup Filter is
properly "TapCleaned”
after each use and
suction does not
return to 100%, then
we suggest that the
HEPA filter be
“TapCleaned”
vigorously until no
more dust can be
Fig. A
Wash once a
month or when
suction appears
reduced.
Warning: Allow 24
hours for drying
before replacing in
unit.
removed, then rinsed under the faucet
and allowed to air dry for 24 hours
before refitting into the vacuum. (Fig.
A) Wash once a month or when
suction appears reduced.
• If the vacuum still does not start,
contact customer service at
1 (800) 798-7398.
2
7
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
GETTING TO KNOW YOUR MINI CANISTER VACUUM
IMPORTANT: In order to ensure that
IMPORTANT, Please Note : The
“TapClean” Rinseable HEPA Dust Cup
Filter & Debris Screen will stop most of
the tiniest dust particles from re-entering
the air you breathe. In fact it stops
99.97% of all particles as small as 0.3
microns - many times smaller than a
human hair!!! Because of this incredible
filtration performance, the HEPA Dust
Cup Filter will quickly accumulate, inside
the white filter folds, many fine dust
particles that are difficult to see but which
will eventually block or reduce your
suction power - if not cleaned properly.
Clean the HEPA Filter and Debris Screen
after each use as described in this
section.
maximum air suction is maintained,
empty the dust cup frequently and shake
out the HEPA filter and Debris Screen at
the same time. Ensure that the rotating
brush is kept free of hair and string which
may accumulate and decrease brush
performance.
Cleaning Air Driven Turbo Brush
Locking Latch
Tilt
Upwards
Turbine
1. To open the Dust Cup (container),
push the dust cup release button
and pull out the Dust Cup
(container ).
From time to time, the turbine of your
turbo brush will require cleaning. To do
this:
1. Remove the turbo brush from the hose
or telescopic extension tube.
2. Slide locking latch forward then tilt the
top housing of the brush upwards. The
top housing is hinged and will tilt up
approximately 45° only.
3. There may be some dust, lint, hair, etc
on the turbine wheel. Remove as much
of this as possible.
4. You may also use the unit’s hose with
crevice tool attached and use the
vacuum to remove any additional
debris from the turbine.
5. Ensure that the turbine wheel moves
freely by rotating it with your finger. If
the turbine does not rotate, call
Customer Service for help.
19
2. Press the dust
cup trap door
release button
to empty the
dirt into a
trash can.
3. To remove the
HEPA filter from
the dust cup
6. Once clean, close the top cover of the
turbo brush and slide the locking latch
toward the rear of the brush to lock.
container hold the dust
cup in one hand and
insert one finger of
your other hand into
the inlet hole on
the dust cup cover
and pull it up.
1. On/Off Power Switch
2. Hose Release Button
3. Dust Cup Release Button
4. Dust Cup (Container)
5. Caddy
11. Dust Cup Handle
12. Flexible Hose
13. Floor Brush
14. Deluxe Brush With Removable
Bristles
15. Extension Tubes (x3)
16. Crevice Tool
17. HEPA Dust Cup Filter
18. Debris Screen
19. Air Driven Turbo Brush
20. Shoulder Strap
Cleaning & Changing the HEPA
Dust Cup Filter
WARNING: Always unplug the unit from
electrical outlet before opening the Dust
Cup (container).
IMPORTANT: Do NOT use the HEPA
dust cup filter without the debris screen in
place.
6. Exhaust Filter Cover
7. Main Unit
8. Intelli-Sense Filter MonitorTM
9. Shoulder Strap Attachment Points
10.Dust Cup Trap Door Release
Button
4. When the HEPA Filter
assembly is removed
from the dust cup, pull
off the debris screen
first. Then to remove
the HEPA Filter from
the Dust Cup Cover,
hold the HEPA filter
with one hand and
with the other hand
pull the dust cup cover
up.
WARNING: After each Use - Always
remove the Filter Debris Screen from the
HEPA Dust Cup Filter, then vigorously
“TapClean” HEPA Filter until no more
dust can be removed.
Illustrations may differ from actual product.
Technical Specifications
Voltage:
Power:
120V., 60Hz.
8.33 Amps
3
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Warning: Always unplug from electrical
Attaching the Shoulder Strap
The Mini Canister Vacuum may be
used with the shoulder strap with or
without the caddy. To attach the
shoulder strap to the unit, attach the
hooks at the ends of the shoulder
strap to the shoulder strap
Using the Flexible Hose
Using the Floor Brush
outlet before opening the dust cup
(container).
To use the flexible hose with the Mini
Canister Vacuum, push the end of
the hose into the suction hole as
shown below. The flexible hose may
be used with the deluxe brush,
crevice tool (see previous page),
floor brush or the air driven turbo
brush. To attach the flexible hose to
the unit, insert the hose end into the
suction hole making sure that the
detent is on the top. This will lock the
hose in place. To remove the hose,
press the hoe release button and
pull the hose out.
1. Attach the flexible hose and the
extension tubes to the vacuum.
2. Attach the floor brush to the extension
tube.
3. You can use the floor brush with the
vacuum either with the caddy or as a
hand vacuum with the shoulder strap.
4. To vacuum bare floors, press the floor-
to-carpet lever on the floor brush down
to lower the bristles.
Note: HEPA dust cup filter must be used
when operating the hand vacuum.
Using The Unit As A Hand
Vacuum
attachment points on the top of the
vacuum. See illustration below.
1. To open the dust cup (container), push
the dust cup release button and pull
out the dust cup. Verify that the HEPA
dust cup filter is inside, then re-attach
the dust cup (container) to the hand
vacuum.
To vacuum carpets,
press the floor-to-
carpet lever up, to
raise the bristles.
The extension tubes can also be
attached to the flexible hose to give
you a longer reach or to help
Very flat carpets can
vacuum the floors with the floor
brush. Just push the wider end of
one of the tubes into the end of the
flexible hose and then attach the
other two tubes to each other. The
floor brush fits to the end of the
extension tubes.
sometimes be vacuumed
with the bristles down.
Air Driven Turbo Brush
The efficiency of your air driven
turbo brush depends on the
Bristle brush rotating at high
speed. Strong air suction is
needed to accomplish this.
In order to ensure that
2. You have the option of using the Mini
Canister Vacuum as a hand held
vacuum or as a canister. To remove
the caddy from the main unit, press
down on the locking lever and lift the
unit up.
Using the Crevice Tool
The crevice tool that is provided with
the Mini Canister Vacuum can be
used either on the vacuum alone,
with the hose or with the extension
tubes. See illustration below.
maximum air suction is maintained, please
read the following instructions:
1. Empty the dust cup frequently.
2. Always shake out the dust cup filter
when emptying the dust cup container.
3. Ensure that the rotating brush is kept
free of hair and string which may
accumulate and decrease brush
performance.
Using the Deluxe Brush with
Removable Bristles
Note: The deluxe brush with
removable bristles can be used with
the hose or the extension tube.
For vacuuming high, hard to reach
places such as ceilings,
4. Keep Air Driven Turbo Brush turbine
free of dirt and foreign matter. (See
page 6 for cleaning instructions.)
Please note that the crevice tool will
only go in the suction hole of the
mini canister one way. See
Using The Unit With Air Driven
Turbo Brush
illustration below. There is a detent
on the top of the crevice tool that
locks in place when inserted into the
suction hole. To remove the crevice
tool from the unit, press the hose
release button to allow you to
remove the accessory.
To replace the Mini Canister back
onto the caddy, slip the front part of
the unit onto the front locking tab of
the caddy (see below) and then lock
the unit in place by pushing it down
until the locking lever clicks in place.
1. Slide the narrow end of the extension
tube into the air driven turbo brush
or the flexible hose.
2. Slide the wide end of the assembled
extension tube onto the round end
of the deluxe hose.
3. Slide the round side of the hose into
the suction hole of the vacuum unit.
4. You can use the mini canister with or
without the shoulder strap.
5. You can now proceed to vacuum
your upholstery.
curtains/drapes, etc., use the
convertible brush with removable
bristles as follows:
1. Insert the convertible brush to the
hose alone or with the extension
tube attached to the hose.
2. If you need a brush action, slide on
the removable bristle brush onto the
deluxe brush. (See illustration
below.)
Slide
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
|