Dx46
FIR-DRIVE
Sound System Processor
Key Features:
•
•
•
•
•
•
116 dB dynamic range
2 analog inputs, 6 analog outputs
2 digital AES/EBU inputs
FIR-DRIVE
TEMP limiter
Configuration via IRIS-Net
Technical Specifications:
Mains Voltage 100 to 240 V AC, 50 to 60 Hz
Power Consumption 25 W
Analog Audio Inputs 2 XLR IN, electronically balanced
2 x XLR THRU OUT, electronically
balanced
General Description:
The Electro-Voice Dx46 is a digital sound system processor with 2 analog
inputs, 2 digital AES/EBU inputs and 6 analog outputs. With high resolution
FIR filters, sophisticated speaker protection and a multi level delay concept
the Dx46 sets new standards for digital loudspaker processors. FIR-DRIVE
provides highly detailed optimization of loudspeaker performance through
the use of complex-phase FIR filters and advanced DSP settings. The con-
figuration and operation of the device can be done via the front panel or the
IRIS-Net software. For remote configuration and control the Dx46 can be
connected via Ethernet or USB. The integrated 2 port ethernet switch allows
daisy chain connection of devices. Direct-access buttons for editing DSP pa-
rameters are available on the front panel. Up to 90 presets (60 factory pre-
sets and 30 programmable user presets) can be used. The integrated FLASH
memory allows software or preset update via Ethernet or USB. Five control
inputs on the rear panel can be used for recall of presets using external
switches or contacts. On the front panel level meters for input and output
signals, output gain reduction, limit and clip LEDs, dedicated Mute buttons,
output channel function indicators (SUB, LO, MID, HI) and a LCD display
(192x32 pixesl) with blue backlight are available. There are 6 preconfigured
configurations plus one free configurable full edit (2 in 6 out) configuration
available. Three dedicated processing groups (user, array, speakers) are
available. For each output 512-tap FIR filters can be used, the PEQ and GEQ
use 48 Bit filter algorithms. A look-ahead Peak limiter and TEMP limiter
(Thermal Energy Management and Protection) are available. The integrated
Signal Generator allows internal generation of pink noise, white noise or sine
signal. Every DSP parameter can be locked and / or hidden. The configura-
tion of the ethernet port can be done via IRIS-Net device scan. Using 24 Bit
AD/DA converters a dynamic range of 116 dB is reached. A switchable input
PAD (-6 dB) can be activated. Configuration is done via IRIS-Net software,
the visualization of the system transfer function is possible using Electro-
Voice Speaker Settings. Please refer to the Dx46 owner‘s manual and IRIS-
Net documentation for more details.
Digital Audio Inputs 1 x XLR AES/EBU IN
1 x XLR AES/EBU THRU OUT
Digital Audio Format AES3, 32 kHz to 192 kHz sample rate
Nominal Input Voltage 1.55 V / +6 dBu
Maximum Input Voltage 17.3 V / +27 dBu
(with -6dB PAD engaged)
Input Impedance 10 kOhm
Common Mode Rejection -85 dB @ 1 kHz (typical)
A/D Conversion 24-Bit Sigma-Delta
Analog Audio Outputs 6 x XLR OUT, electronically balanced
Nominal Output Voltage 1.55 V / +6 dBu
Maximum Output Voltage 8.7 V / +21 dBu
Output Impedance 50 Ohm
D/A Conversion 24-Bit Sigma-Delta
Frequency Response 20 Hz to 22 kHz (+/-0.5 dB)
THD+N < 0.002% (band limited 22 Hz to 22
kHz)
Dynamic Range 116 dB (A-weighted)
USB USB Type B on front panel (PC Inter-
face)
Ethernet 2 x RJ-45 ports, 100 MB, Integrated
Switch
Control Port 1 x 6-pole Euro block
Software Configurable for Preset
Recall
Sample Rate 48 kHz
Data Format 24-Bit
Internal Processing 48-Bit Double Precision
Signal Processing Parametric EQs, 31 band Graphic
EQs, Delays, Routing, X-Over, 512
Taps FIR filters, PA limiter, TEMP limi-
ter, Level, Polarity, Signal generator
Operating Temperature Range 0 °C to 40 °C
Dimensions (WxHxD) 19 x 13.9 x 1.72 inch (483 x 356.1 x
43.6 mm)
Weight (Net) 4.8 kg
Download from Www.Somanuals.com. All Manuals Search And Download.
Dx46
FIR-DRIVE
Sound System Processor
DSP Signal Flow Chart:
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions Drawings:
Rear View:
Dx46 Part Number:
Dx46, 120 V -- F01U126855
Dx46, 230 V -- F01U126854
Agency Approvals
CE
FCC, IC
CB
U.S.A. and Canada only. For customer orders, contact Customer Service at:
800/392-3497 Fax: 800/955-6831
Europe, Africa, and Middle East only. For customer orders, contact Customer Service at:
+ 49 9421-706 0 Fax: + 49 9421-706 265
12000 Portland Avenue South, Burnsville, MN 55337
Phone: 952/884-4051, Fax: 952/884-0043
Other International locations. For customer orders, Contact Customer Service at:
+ 1 952 884-4051 Fax: + 1 952 887-9212
© Bosch Communications Systems 03/2010
For warranty repair or service information, contact the Service Repair department at:
800/685-2606
Part Number F01U126854 Vs 01
For technical assistance, contact Technical Support at: 866/78AUDIO
Specifications subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
|