Elation Professional Fan X Fogger User Manual

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.  
Modular Design for Easy, Cost Effective Maintenance.  
Standardized Interface Allows Interchangeable Control Modules on All Models.  
Illuminated Fluid Tank for Easy Monitoring for the Level of Fog Fluid.  
Electronic Low Fluid Monitoring Protects Pump from Running Dry  
Heavy-Duty, Quiet Pump for Continuous, Silent Operation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Congratulations on the purchase of your new  
ANTARI X Fogger  
Introduction  
Thank you for choosing an ANTARI X Fogger. You now own a  
rugged and powerful state-of-the-art machine. Prior to use, we  
suggest that you carefully read all of the instructions. By  
following the suggestions found in this user manual, you can look  
forward to the reliable and satisfactory performance of your  
ANTARI Fog Machine for years to come.  
Please follow these operation, safety and maintenance instructions  
to ensure a long and safe life for your fog machine.  
Cautions  
Risk of electric shock. Disconnect the appliance from the electric  
supply before removing the cover. Note: there are no user  
serviceable parts inside.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safeguards  
Danger of Electric Shock  
! Keep this device dry.  
! For inside use only. Not designed for outside use.  
! For the 110V models, use 3-prong grounded electrical  
outlet only. Prior to use take care to determine that the  
unit is installed at the rated voltage.  
! Always unplug your ANTARI Fog Machine before filling  
its tank.  
! Keep fog machine upright.  
! Unplug the machine when not in use.  
! This machine is not water- or splash-proof. If  
moisture, water, or fog liquid gets inside the housing,  
immediately unplug the unit and contact a service  
technician or your ANTARI dealer before using it again.  
! No user serviceable parts inside. Refer to your ANTARI  
dealer or other qualified service personnel.  
Danger of Burns  
! For adult use only. Fog machine must be installed out  
of the reach of children. Never leave the unit running  
unattended.  
! Never aim the output nozzle directly at people.  
! Fog machine output aren is very hot. Avoid coming  
within 60 cm of the output nozzle during operation.  
! Locate the fog machine in a well-ventilated area. Never  
cover the unit's vents. In order to guarantee adequate  
ventilation, allow a free air space of at least 20 cm  
around the sides and top of the unit.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
! Never aim the output nozzle at open flames.  
! If the supply cord is damaged, it must be replaced by  
manufacturer or its service agent or similarly qualified  
personnel in order to avoid a hazard.  
! The output nozzle becomes very hot during operation  
(3000C). Keep flammable materials at least 50 cm away  
from the nozzle.  
! Always allow your ANTARI X Fogger to cool down  
before attempting to clean or service it.  
Danger of Explosion  
! Never add flammable liquids of any kind (oil, gas,  
perfume) to the fog liquid.  
! Use only the high-quality, water-based ANTARI fog .  
Other fog liquids may cause clogging or "spitting".  
! Always make sure there is sufficient liquid in the fog  
liquid tank. Operating this unit without liquid will  
cause damage to the pump as well as over-heating of  
the heater.  
! If your ANTARI Fog Machine fails to work properly,  
discontinue use immediately. Drain all fog liquid from  
the tank, pack the unit securely (preferably in the  
original packing material), and return it to your  
ANTARI dealer for service.  
! Always drain tank before mailing or transporting this  
unit.  
! Never drink fog liquid. If it is ingested, call a doctor  
immediately. If fog liquid comes in contact with skin  
or eyes, rinse thoroughly with water.  
Important:  
Pay attention to all warning labels and instructions printed on the  
exterior of your ANTARI Fog Machine.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unpacking & Inspection  
Open the shipping carton and verify that all equipment necessary to  
operate the system has arrived intact.  
Before beginning initial setup of your ANTARI Fog Machine, make sure  
that there is no evident damage caused by transportation. In the event  
that the unit's housing or cable is damaged, do not plug it in and do not  
attempt to use it until after contacting your ANTARI dealer for  
assistance.  
Setup  
Remove all packing materials from shipping box. Check  
that all foam and plastic padding is removed, especially in  
the nozzle area.  
Place fog machine on a flat surface and remove fog liquid  
tank cap.  
Fill with only ANTARI Fog Fluid. ANTARI X Fogger only  
works with uncontaminatedANTARI Fog Fluid. Other fluids  
may cause spitting and serious clogging problem and could  
resuit in the production of an unhealthful fog.The use of other  
fluids voids the wananty of the ANTARI X Fogger. When  
filled, place cap back on liquid tank.  
Firmly attach the control module cable to the connector  
inside the rear chamber of the machine.  
WARNING:  
Use of any fluid othe than ANTARI fog fluid or modification or  
attempted to unauthorized repair of the fog machine will  
immediately invalidate the warranty.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
! Plug power cord into a grounded electrical outlet.  
Turn power switch on rear of unit to " ON" position.  
Warm-up is complete when the display on control  
module.shows " Ready to Fog"  
! To emit fog, press the appropriate button on the  
control module for the desired length of time.  
! The control unit's display will cycle " Warming up" and  
" Ready to Fog " as the machine re-heats to the proper  
operating temperature.  
! For further information on operating your ANTARI Fog  
Machine, see the section titled, "Contrd Module  
Operation".on pagexx.  
If your model includes a mounting bracket designed for overhead  
installation, it may be installed at floor level or suspended  
overhead. If the unit is to be mounted using the bracket, it is  
important that the fog does not shoot directly at any one's face.  
Whatever installation method you choose, do not allow the unit  
to have more than a 15 degree angle of inclination.  
Important:  
Always monitor tank fluid level as you are fogging. Running a fog  
machine with no fluid can permanently damage the unit.  
If you experience low output, pump noise or no output at all,  
unplug immediately. Check fluid level, the external fuse,control  
module connection, and power from the wall. If all of the above  
appears to be O.K., plug the unit in again. If fog does not come  
out after holding the control module button down for 30 seconds,  
check the hose attached to the tank to make sure there is fluid  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
going through the hose. If you are unable to determine the cause  
of the problem, do not simply continue pushing the control  
module button, as this may damage the unit. Return the  
machine to your ANTARI dealer immediately.  
Control Module Operation  
FUNCITON  
VOLUME  
ENTER  
MANUAL  
ON / OFF  
TIMER  
ESC  
! X-10: 10 meter wired multi-function remote control  
module with 5-pin XLR connector for ANTARI X Series  
models X-310, X-510, X-515, X-530. Its interface  
allows the operator to customize fog machine functions  
by adjusting fogging duration, interval and volume. Its  
LCD displays current operating parameters, which are  
automatically stored in non-volatile memory, allowing  
the machine to be powered down without losing  
function settings. Instructions below:  
1.Via the Function key, you can adjust the desired  
settings. Pressing the Function key will cycle through  
different options including Volume, Timer, Heat &  
Fan. The Enter (Volume) Key is used to select the  
desired option. To adjust fog output volume setting,  
simply go into Volume option. Adjust the volume  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
percentage (within the range of 1% to nonstop burst) by  
means of Up / Down keys. To adjust timer setting, go  
into Timer option. Cycle through Interval (within the  
range of 1 to 900 seconds), Duration (within the range  
of 1 to 200 seconds), and Volume (within the range of  
1% to nonstop burst) by means of Up / Down keys. Use  
Enter (Volume) Key to select each option and make  
changes as desired. To turn off the heater and fan, go  
into Heat & Fan option. Use Enter (Volume) Key to  
confirm the selection. Use On/Off (Manual) Key to turn  
it on.  
2.Press the Timer key to activate the timer function.  
The display shows the adjusted interval and the device  
counts the seconds down to "0". After that, the fog  
emission is triggered at the volume adjusted under  
"Timer Out". The duration depends on the settings  
adjusted under "Duration Set". If you wish to deactivate  
the timer function, press the Timer key once more.  
3.Press the Volume switch for immediate triggering of  
the fog emission at the volume adjusted under "Volume  
Out". Press the Volume switch once more in order to  
stop the fog emission.  
4.Press the Manual key for immediate triggering of the  
fog emission at 100 % volume. Let the Manual key loose  
in order to stop the fog emission.  
! X-20: DMX Interface module. Please refer to the section  
on Page 8 titled X-20 DMX Module Settings.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
! X-30: All the X-10 features plus wireless capability.  
Wireless operation is possible up to a distance of 50  
meters. The address can be set from 0 to 8, which means  
total 9 different units can be controlled separately or in  
any combination desired. Press function to cycle to RF  
mode to select desired address number. Make sure the  
address setting on the X-30 matchs the address setting  
on the transmitter. There are two buttons on the  
transmitter. One is to release fog, the other is to stop the  
operation.  
ANTARI X-20 DMX Module Settings  
Value  
Function  
OFF  
Volume Control( 5% - 95%)  
0 - 5  
6 - 249  
Maximum Volume Output ( 100%)  
250 - 255  
On X Foggers such as X-510, X-515 and X-530, X-20 uses only 1  
channel to control volume output operation. On X Fazer such as  
X-310, X-20 uses 2 channels to control both fog volume and fan  
volume. Whatever channel you select on the unit, the channel  
next to it will be selected automatically for fan volume control.  
Each channel has a value range of 0 to 225. Timer functions such  
as duration and interval can be programmed using the DMX  
controller or the DMX control software being used by lighting and  
effects operator.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
If Channel has a value from 0 to 5, the unit is OFF.  
Between the values 6 to 249 the volume of fog output is  
regulated.With 6 being the minimum volume of fog produced and  
249 approaching the maximum. The volume output rises as the  
DMX value is increased.  
If Channel has a value from 250 TO 255, the machine will operate at  
maximum output.  
Note: In the example above, if the machine were assigned the  
DMX address of 124, Channel would correspond to DMX address  
124.  
In general, ANTARI X Fogger with X-20 DMX Module conform to  
the following performance specifications:  
1.Average Operating temperature = 2500C  
2.Fogger can maintain maximum output for 30 seconds  
or more  
3.Fogger can maintain constant output at 30% volume  
setting (roughly a value of 75).  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
Do not allow the fog liquid to become contaminated. Always  
replace the caps on the fog liquid container and the fog machine  
liquid tank immediately after filling.  
After every 40 hours of continuous operation, it is recommended to  
run a cleaning solution composed of 80% distilled water and 20%  
white vinegar through the system to prevent the accumulation of  
particulate matter in the heating element. The recommended  
cleaning regimen is as follows:  
1.Empty all fog fluid from machine. Add cleaning  
solution to tank. Plug unit in and begin warm up.  
2.Run unit in a well-ventilated area until tank is  
empty.  
3.Cleaning is now complete. Refill with fog liquid.  
Note: All fog machines are prone to clogging due to the thick  
consistency of fog fluid and the high temperature at which it  
vaporizes. However, a properly maintained fog machine should  
provide years of reliable use.  
Clean with a dry cloth only. Store dry.  
Cleaning your fog machine regularly will help reduce costly  
parts replacement and repair charges.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Notes  
! All fog machines develop condensation around the  
output nozzle. Because this may result in some  
moisture accumulation on the surface below the output  
nozzle, consider this condensation when installing your  
unit.  
! All fog machines may sputter small amounts of fog  
occasionally during operation and for a minute or so  
after being turned off.  
! All fog machines have a recycling period after long  
bursts when the machine will shut itself down for a  
short period in order to heat up again. During this time,  
no fog can be produced.  
! If the supply cord is damaged, it must be replaced by  
ANTARI or its unhorized dealer to avoid a hazard.  
Please read and save these instructions  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
Atari Lighting and Effect Ltd. warrants to the original purchaser that the  
ANTARI X Fogger will be free from original defects in workmanship and  
material for a period of six months from the date of purchase. During the  
warranty period, machines will be repaired or replaced at the option of  
ANTARI or its designateddealer.  
If the purchaserreturns a completedregistration card toANTARI or its  
designated dealer within 30 days of purchase, ANTARI will extend the  
limited warranty onthe pump assemblyand the heatexchanger assembly toa  
FULL YEAR from the date of purchase. If the warranty card is not received by  
ANTARI or its designateddealer, the warranty will remaineffective for six  
months.  
The warranty does not extend to any parts of the ANTARI X Fogger that have  
been subject to misuse or accident. Neither does the warranty cover any  
ANTARI X Fogger that has been opened, modified or repaired other than by  
ANTARI or its designateddealer.  
The warranty willnot apply ifprocedures described inthe Instruction Manual  
are not followed. It is the user's obligation to clean and maintain the ANTARI  
X Fogger accordingto these instructions, and to followacceptable practices  
for handling electricaldevices with heatingelements.  
NOTE: USE OF ANY FLUID OTHER THAN ANTARI FOG FLUID WILL  
VOID WARRANTY.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ei Electronics Switch EI159 User Manual
Extron electronic Power Supply P S 100 User Manual
Extron electronic Scanner SRI 200 User Manual
Extron electronic Switch FOXBOX 4G DVI User Manual
Fagor America Electric Pressure Cooker 85M7 User Manual
Fellowes Paper Shredder 450Ms User Manual
Frigidaire Range 316135932 User Manual
GE Microwave Oven PVM2070SMSS User Manual
GE Monogram Cooktop ZGU365 User Manual
GN Netcom Cordless Telephone 9000MWD User Manual