Power Blower
Operator's Manual
MODEL
PB-265L
WARNING
Read rules for safeoperationandinstructions carefully. ECHOprovidesthisOperator's
Manual,whichmustbereadandunderstoodforproperand safe operation.
X753002580
10/06
X7531180400
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
3
SAFETY
MANUAL SAFETY SYMBOLS AND IMPORTANT INFORMATION
Throughout this manual and on the product itself, you will find safety alerts and helpful, informational messages
preceded by symbols or key words. The following is an explanation of those symbols and key words.
CIRCLE AND SLASH SYMBOL
DANGER
This symbol means the specific action
shown is prohibited. Ignoring these
prohibitions can result in serious or fatal
injury.
Thesafetyalertsymbolaccompaniedbytheword
“DANGER”callsattentiontoanactorcondition
whichWILLleadtoseriouspersonalinjuryordeath
ifnotavoided.
NOTE
WARNING
Thesafetyalertsymbolaccompaniedbytheword
“WARNING”callsattentiontoanactorcondition
whichCANleadtoseriouspersonalinjuryordeath
ifnotavoided.
This enclosed message provides tips for use, care
and maintenance of the unit.
IMPORTANT
The enclosed message provides information
necessary for the protection of the unit.
CAUTION
Thesafetyalertsymbolaccompaniedbytheword
“CAUTION”callsattentiontoanactorcondition
whichmayleadtominorormoderatepersonalinjury
ifnotavoided.
INTERNATIONAL SYMBOLS
Symbol
description/application
Symbol
description/application
Symbol form/shape
Symbol form/shape
Symbol
Symbol
description/application
Symbol form/shape
Symbol form/shape
description/application
Ignition
ON/OFF
Emergency stop
Read and understand
Operator's Manual.
Fuel and oil mixture
Finger Severing
Carburetor adjustment
- Low speed mixture
Wear eyes, ears and
head protection
Primerbulb
Wear hand
protection.Use
twohanded.
Carburetor adjustment
- High speed mixture
Carburetor adjustment
- Idle speed
Hot
Surface
Choke Control
"Run"
Position
Choke Control
"Cold Start"
Position
Wear slip
resistant foot
wear.
Safety/Alert
(ChokeOpen)
(Choke Closed)
DONOTallow
flamesorsparks
nearfuel.
DO NOT smoke
nearfuel.
Idle Speed
Fast Speed
PERSONAL CONDITION AND SAFETY EQUIPMENT
WARNING
Power Blower users risk injury to themselves and others if the power blower is used improperly or safety precautions
are not followed. Proper clothing and safety gear must be worn when operating a blower.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Physical Condition
Your judgment and physical dexterity may not be good:
• if you are tired or sick,
• if you are taking medication,
• if you have taken alcohol or drugs.
Operate unit only if you are physically and mentally well.
Eye Protection
Wear eye protection that meets ANSI Z87.1 or CE requirements whenever you operate the unit.
Hand Protection
Wear no-slip, heavy-duty work gloves to improve your grip on the blower handle. Gloves also reduce the transmission
of machine vibration to your hands.
Breathing Protection
Wear a facemask to protect against dust.
Hearing Protection
ECHO recommends wearing hearing protection whenever unit is used.
Proper Clothing
Wear snug fitting, durable clothing;
• Pants should have long legs, shirts with long sleeves.
• DONOTWEARSHORTS,
• DONOTWEARTIES,SCARVES,andJEWELRY.
Wear sturdy work shoes with nonskid soles:
• DONOTWEAROPENTOEDSHOES,
• DONOTOPERATEUNITBAREFOOTED.
Keep long hair away from engine and blower intake. Retain hair with cap or net.
Hot Humid Weather
Heavy protective clothing can increase operator fatigue, which may lead to heat stroke. Schedule heavy work for early
morning or late afternoon hours when temperatures are cooler.
Vibration and Cold
It is believed that a condition called Raynaud’s Phenomenon, which affects the fingers of certain individuals, may be
brought about by exposure to vibration and cold. Exposure to vibration and cold may cause tingling and burning
sensations, followed by loss of color and numbness in the fingers. The following precautions are strongly recom-
mended, because the minimum exposure, which might trigger the ailment, is unknown.
• Keep your body warm, especially the head, neck, feet, ankles,
hands, and wrists.
• Maintain good blood circulation by performing vigorous arm
exercises during frequent work breaks, and also by not smoking.
• Limit the hours of operation. Try to fill each day with jobs where
operating the unit or other hand-held power equipment is not
required.
• If you experience discomfort, redness, and swelling of the fingers
followed by whitening and loss of feeling, consult your physi-
cian before further exposing yourself to cold and vibration.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
5
Repetitive Stress Injuries
It is believed that overusing the muscles and tendons of the fingers, hands, arms, and shoulders may cause soreness,
swelling, numbness, weakness, and extreme pain in those areas. Certain repetitive hand activities may put you at a high
risk for developing a Repetitive Stress Injury (RSI). An extreme RSI condition is Carpal Tunnel Syndrome (CTS), which
could occur when your wrist swells and squeezes a vital nerve that runs through the area.
Some believe that prolonged exposure to vibration may contribute to CTS. CTS can cause severe pain for months or
even years.
To reduce the risk of RSI/CTS, do the following:
• Avoid using your wrist in a bent, extended, or twisted position.
Instead, try to maintain a straight wrist position. Also, when
grasping, use your whole hand, not just the thumb and index
finger.
• Take periodic breaks to minimize repetition and rest your hands.
• Reduce the speed and force with which you do the repetitive
movement.
• Do exercises to strengthen the hand and arm muscles.
• Immediately stop using all power equipment and consult a
doctor if you feel tingling, numbness, or pain in the fingers,
hands, wrists, or arms. The sooner RSI/CTS is diagnosed, the
more likely permanent nerve and muscle damage can be pre-
vented.
DANGER
Do not operate this product indoors or in inadequately ventilated
areas. Engine exhaust contains poisonous emissions and can
cause serious injury or death.
Read the Manuals
• Provide all users of this equipment with the Operator’s Manual
and Safety Manual for instructions on Safe Operation.
Clear the Work Area
• Spectators and fellow workers must be warned, and children and
animals prevented from coming nearer than 15 m (50 ft.) while the
unit is in use.
• Take wind conditions into account: avoid open doors and
windows.
• Do not point blower at people or animals.
Keep a Firm Grip
• Hold the stick handle with thumb and fingers encircling the
handle.
Keep a Solid Stance
• Maintain footing and balance at all times. Do not stand on
slippery, uneven, or unstable surfaces. Do not work in odd
positions or on ladders. Do not over reach.
Avoid Hot Surfaces
• Keep exhaust area clear of flammable debris. Avoid contact
during and immediately after operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
EQUIPMENT CHECK
WARNING
Use only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment
combination. ECHO, INC. will not be responsible for the failure of cutting devices, attachments or accessories which
have not been tested and approved by ECHO. Read and comply with all safety instructions listed in this manual and
safety manual.
• Check unit for loose/missing nuts, bolts and screws. Tighten
and/or replace as needed.
• Inspect fuel lines, tank and area around carburetor for fuel leaks. DO NOT operate unit if leaks are found.
• Do not use blower if any part is missing or damaged.
• Have repairs done only by an authorized ECHO Service dealer.
• Do not use any attachment, accessory or replacement part unless it is recommended in this Operator's Manual.
EMISSION CONTROL
EPA Phase 2
The emission control system for these engines are EM/TWC (Engine and Catalyst Modification).
IMPORTANTENGINEINFORMATION
ENGINE FAMILY: 6EHXS.0254KF DISPLACEMENT: 25.4 CC
EMISSION COMPLIANCE PERIOD : 300 HRS.
THIS ENGINE MEETS U.S. EPA PH2 AND 2005 - 2006
CALIFORNIA EMISSION REGULATIONS FOR SOREs.
REFER TO OWNER'S MANUAL FOR MAINTENANCE
SPECIFICATIONS AND ADJUSTMENTS.
An Emission Control Label is located on the unit. (This is an EXAMPLE
ONLY,informationonlabelvariesbyengineFAMILY).
PRODUCT EMISSION DURABILITY
The 300 hour emission durability compliance period is the time span selected by the manufacturer certifying the
engine emissions output meets applicable emissions regulations, provided that approved maintenance procedures are
followed as listed in the Maintenance Section of this manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
7
DESCRIPTION
Locate the safety decals on your unit. Make sure the decals are legible and that you understand and follow the instruc-
tions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See PARTS ORDERING
instructions for specific information.
3
4
13
2
5
1
14
12
11
6
10
7
9
8
15
18
17
16
1
Hot Decal (near muffler and engine)
P/N89016006361
2
3
Sound Label (located on blower housing)
P/NX508000120
65 Category I
Measured at 50 ft. (15m) per ANSI B175.2
General Warning Decal (located on blower housing)
P/N89016009461
Download from Www.Somanuals.com. All Manuals Search And Download.
8
1. SAFETYDECAL-Listsimportantsafetyprecautions.
2. SAFETYDECAL-Listsimportantsafetyprecautions.
3. SAFETYDECAL-Listsimportantsafetyprecautions.
4. SPARKPLUG-Providessparktoignitefuelmixture.
5. SPARKARRESTOR-CATALYTICMUFFLER/MUFFLER-Themufflerorcatalyticmufflercontrolsexhaustnoise
and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep
exhaust area clear of flammable debris.
6. SERIALNUMBERLABEL- Listsmodelnumberandserialnumberofunit.
7. RECOILSTARTERHANDLE-Pullrecoilhandleslowlyuntilstarterengages,thenquicklyandfirmly. When
engine starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur.
8. FUELTANKCAP-Coversandsealsfueltank.
9. FUELTANK-Containsfuelandfuelfilter.
10. AIRCLEANER-Containsreplaceableairfilterelement.
11. HANDLE - Rotates downward for throttle control access. Spring loaded for flexible operation.
12. THROTTLEPOSITIONLEVER/STOPSWITCH-Combinationstopswitchandvariablespeedthrottlelever.
When the lever is moved all the way forward the blower is at Wide Open Throttle (W.O.T.). When the lever is
moved rearward to detent, the blower is at idle. When the lever is moved rearward past the idle detent the blower will
stop.
13. CHOKE - Choke is located on the side of the air cleaner. Move choke lever to "COLD START" ( ) to close choke
for cold starting. Move choke lever to "RUN" ( ) position to open choke.
14. PURGE BULB - Pumping purge bulb before starting engine draws fresh fuel from the fuel tank, purging air from
the carburetor. Pump purge bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump purge
bulb an additional 4 or 5 times.
15. SHOULDER HARNESS - Used to support unit on operator's back. The straps are adjustable.
16. BLOWERPIPES-Exclusivepositivelockingsystem.
17. FLEXIBLEPIPE-Allowsforfullrangeofmovement.
18. STICKHANDLE-Usedbyoperatortodirectairflow.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
9
CONTENTS
__ 1 - PowerHead
__ 1 - FlexPipe
__ 1 - SwivelPipe
__ 1 - StraightPipe
__ 1 - Straight Pipe w/decal
__ 1 - Operator's Manual
__ 1 - Warranty Registration Card
__ 1 - ECHO Emissions and Warranty Statement
__ 1 - PlasticBag
__ 2 - Clamps w/screws
__ 1 - Stick Handle Assembly
__ 1 - Echo Power Blend TM 2-stroke oil sample
Download from Www.Somanuals.com. All Manuals Search And Download.
10
ASSEMBLY
WARNING
Never perform maintenance or assembly procedures with engine
running or serious personal injury may result.
INSTALL BLOWER PIPES / STICK HANDLE
1. Assemble clamps (A) onto both ends of flexible pipe (B).
2. Assemble swivel pipe (C) into flexible pipe (B) and tighten clamp
(A).
3. Assemble flexible pipe (B) to elbow (D) on blower and tighten
clamp(A).
D
B
NOTE
A light lubricant may be used to ease assembly of flexible pipe to
blowerelbow.
C
A
H
4. Loosen wing nut (E) completely and open stick handle clamp.
5. Align notches (F) in handle clamp with tabs (G).
6. Slide stick handle onto swivel pipe (C). Stick handle should be
angled away from operator.
H
7. Position stick handle (H) for comfortable operation, and tighten
wingnut(E).
F
G
8. Assemble straight pipe (I) onto swivel pipe (C), until you feel light
resistance. Do not force connection. Hold swivel pipe and turn
straight pipe counter clockwise, engaging positive locking
channels,until connection is firm. Do not force connention.
E
B
9. Assemble straight pipe with decal (J) to straight pipe (I) as in step
8.
NOTE
Blower use will eventually loosen pipe connections. Exclusive
positive locking system allows pipes to be tightened. If loosening
occurs, remove two straight pipes and install according to instruc-
tions 8 & 9.
I
C
J
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
11
OPERATION
Fuel to Oil Mix - 50:1 Ratio
NOTE:Useofunmixed,improperlymixed,orfuelolderthan90days,
(stale fuel), may cause hard starting, poor performance, or severe
engine damage and void the product warranty. Read and follow
instructions in the Storage section of this manual.
U.S.
METRIC
GAS OIL
GAS
OIL
Gallons
Fl. oz.
Liter
cc.
FUEL
Fuel Requirements
1
2
5
2.6
5.2
13
4
8
20
80
160
400
Gasoline - Use 89 Octane [R+M/2] (mid grade or higher) gasoline
known to be good quality. Gasoline may contain up to 15% MTBE
(methyl tertiary-butyl ether). Gasohol containing methyl (wood) alcohol
is NOT approved.
Mixing Instructions
1. Fill an approved fuel container with half
of the required amount of gasoline.
2. Add the proper amount of 2-stroke oil to
gasoline.
3. Close container and shake to mix oil with
gasoline.
TwoStrokeOil-Atwo-strokeengineoilmeetingISO-L-EGD(ISO/CD
13738) and J.A.S.O. FC Standards must be used. Echo brand premium
Power Blend TM Universal 2-Stroke Oil meets these standards. Engine
problems due to inadequate lubrication caused by failure to use an
ISO-L-EGDandJ.A.S.O.FCcertifiedoil,suchasEchopremiumPower
Blend TM, will void the two-stroke engine warranty. (Emission related
parts only are covered for two years, regardless of two-stroke oil used,
per the statement listed in the Emission Defect Warranty Explanation.)
4. Add remaining gasoline, close fuel
container,andremix.
IMPORTANT
Spilled fuel is a leading cause of
hydrocarbon emissions. Some states
may require the use of automatic fuel
shut-off containers to reduce fuel
spillage.
IMPORTANT
EchopremiumPowerBlendTM Universal2-StrokeOilmaybemixed
at 50:1 ratio for application in all Echo engines sold in the past
regardless of ratio specified in those manuals.
Handling Fuel
After use
• DO NOT store a unit with fuel in its
tank. Leaks can occur. Return unused
fuel to an approved fuel storage
container.
DANGER
FuelisVERYflammable.Useextremecarewhenmixing,storingor
handling or serious personal injury may result.
• Use an approved fuel container.
Storage - Fuel storage laws vary by locality.
Contact your local government for the laws
affecting your area. As a precaution, store
fuel in an approved, airtight container. Store
in a well-ventilated, unoccupied building,
away from sparks and flames.
• DONOTsmokenearfuel.
• DO NOT allow flames or sparks near fuel.
• Fuel tanks/cans may be under pressure. Always loosen fuel caps
slowly allowing pressure to equalize.
• NEVERrefuelaunitwhentheengineisHOTorRUNNING!
• DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks outdoors
over bare ground.
• DO NOT overfill fuel tank. Wipe up spills immediately.
• Securely tighten fuel tank cap and close fuel container after
refueling.
IMPORTANT
Stored fuel ages. Do not mix more fuel
than you expect to use in thirty (30)
days, ninety (90) days when a fuel
stabilizer is added.
• Inspect for fuel leakage. If fuel leakage is found, do not start or
operate unit until leakage is repaired.
• Move at least 3m (10 ft.) from refueling location before starting
the engine.
IMPORTANT
Stored two-stroke fuel may separate.
ALWAYS shake fuel container
thoroughly before each use.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
STARTING COLD ENGINE
• Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
• Rotate throttle handle downward to a comfortable operating position.
1. Throttle Position Lever
Move throttle position lever (A) to START/IDLE DETENT
A
position(
).
2. Choke
Move choke (B) to "Cold Start" ( ) position.
B
3. Purge Bulb
Pump purge bulb (C) until fuel is visible and flows freely in the
clear fuel tank return line.
4. Recoil Starter
Pullrecoilstarterhandle(D)untilenginefires, ormaximum5pulls.
C
5. Choke
Move choke (B) to run ( ) position and if necessary, restart
engine.
NOTE
D
If engine does not start after 5 pulls, repeat instructions 2-5.
NOTE
Allow engine to warm up before use.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
13
STARTING WARM ENGINE
A
The starting procedure is the same as Cold Start except DO NOT close
the choke.
1. Throttle Position Lever
Move throttle position lever (A) to start/idle detent posi-
tion(
).
2. Purge Bulb
Pump purge bulb (C) until fuel is visible and flows freely in the
clear fuel tank return line.
C
3. Recoil Starter
Pull recoil starter handle (D) and engine should start.
D
NOTE
If engine does not start after 5 pulls, use cold start procedures.
STOPPING ENGINE
1. Throttle Position Lever
Move throttle position lever (A) to idle detent position(
allow engine to return to idle before shutting off engine.
) and
A
2. Move throttle lever (A) to " " (Stop) position.
WARNING
If engine does not stop when throttle lever is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using blower
again.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
OPERATING BLOWER
WARNING
Always wear safety glasses, hearing protection, face filter mask and
take all safety precautions or serious personal injury may result.
Do not point the blower pipe in the direction of people or pets.
Read the Safety Section carefully.
IMPORTANT
To avoid engine damage due to over revving, do not block
blower pipe opening.
1. Use only during appropriate hours.
2. Allow the engine to warm up at a fast idle for a few minutes.
3. Set engine speed with throttle position lever (A).
A
4. Use lower speed to blow dry grass and leaves from walks, patios
and drives.
5. Additional speed may be necessary to clean leaves from a lawn or
flowerbed.
6. Higher speed may be necessary to move gravel, dirt, snow, bottles
or cans from a driveway, street, parking lot or stadium.
NOTE
Never use a higher speed setting than necessary to perform a task.
Remember, the higher the engine speed, the louder the blower noise.
Minimize dust by using blower at lower speeds and by dampening
material with water/mist when necessary. Keep debris on your
property.
Be Smart - be a good neighbor.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
15
MAINTENANCE
Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help
your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your
unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOURSELF or have the
ECHO Dealer do it, each maintenance task has been graded. If task is not listed, see your ECHO Dealer for repairs.
SKILL LEVELS
Level1=
Level2=
Level3=
Easy to do. Most required tools come with unit.
Moderate difficulty. Some specialized tools may be required.
Experiencerequired. Specializedtoolsarerequired. Echorecommends
that the unit be returned to your ECHO dealer for service.
ECHO offers REPOWERTM Maintenance Kits and Parts to make your maintenance job easier. Just below each task
heading are listed the various part numbers required for that task. See your ECHO dealer for these parts.
MAINTENANCE INTERVALS
DAILY
OR
BEFORE
USE
3
6
REQ'D
SKILL
LEVEL
COMPONENT/
SYSTEM
MAINTENANCE
PROCEDURE
EVERY
REFUEL
MONTHS
OR 90
HOURS
MONTHS
OR 270
HOURS
YEARLY
Recommended Echo Dealer Maintenance Procedures
Inspect/Clean/Decarbon
Do-It-Yourself Maintenance Procedures
Cylinder Exhaust Port
3
I / C
R*
I
Air Filter
Inspect/Clean/Replace
Inspect/Clean
1
2
1
1
2
2
1
2
1
I / C
I / C
Choke
Fuel Filter
Inspect/Replace
Inspect/Replace
Inspect/Clean
R*
Fuel System, Leaks
Cooling System
Muffler Spark Arrestor
Recoil Starter Rope
Spark Plug
I
I / R*
I / C
Inspect/Replace
Inspect/Clean
I / R*
I / C
I / C
I / R*
Inspect/Clean
R*
Screws/Nuts/Bolts
Inspect/Tighten/Replace
I / R*
MAINTENANCE PROCEDURE LETTER CODES: I = INSPECT, R = REPLACE, C = CLEAN
IMPORTANT NOTE - Time intervals shown are maximum. Actual use and your experience will determine the frequency of required
maintenance.
MAINTENANCE PROCEDURE NOTES:
* All recommendations to replace are based on the finding of damage or wear during inspection.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
AIR FILTER
Level1.
Tools required: 25-50mm(1-2in.)Cleaningbrush
Parts required: Airfilter
1. Close choke (Cold Start Position [ ]). This prevents dirt from
entering the carburetor throat when the air filter is removed. Brush
accumulateddirtfromaircleanerarea.
2. Remove air filter cover. Brush dirt from inside cover.
3. Removeairfilterandlightlybrushdebrisfromfilter. Replacefilter
if it is damaged, fuel soaked, very dirty, or the rubber sealing
edges are deformed.
4. If filter can be reused, be certain it:
• Fits tightly in the air filter cavity.
• Is installed with the original side out.
5. Installairfiltercover.
FUEL FILTER
Level1.
Tools required: 200-250mm(8-10in.)lengthofwire with one end bent
into a hook, clean rag, funnel, and an approved fuel
container
Parts required: Fuel line and filter
DANGER
FuelisVERYflammable.Useextremecarewhenmixing,storingor
handling.
1. Use a clean rag to remove loose dirt from around fuel cap and
empty fuel tank.
2. Use the “fuel line hook” to pull the fuel line and filter from the
tank.
3. Remove the filter from the line and install the new filter.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
17
SPARK PLUG
Level2.
Tools required: T-Wrench, Feeler gauge
Parts Required: Spark plug
IMPORTANT
Use only NGK BPM8Y spark plug otherwise severe engine
damage may occur.
1. Remove spark plug and check for fouling, worn and rounded
center electrode.
2. Clean the plug or replace with a new one. DO NOT sand blast to
clean. Remaining sand will damage engine.
3. Adjust spark plug gap by bending outer electrode.
4. Tightensparkplugto150-170kg/cm(130-150in.lb.).
COOLING SYSTEM
Level2.
Tools required: 4mmx130mm(5")longhexwrench, cleaningbrush
Parts Required: None, if you are careful.
IMPORTANT
To maintain proper engine operating temperatures, cooling air must
pass freely through the cylinder fin area. This flow of air carries
combustion heat away from the engine.
Overheating and engine seizure can occur when:
• Air intakes are blocked, preventing cooling air from reaching the
cylinder.
• Dust and grass build up on the outside of the cylinder. This build
up insulates the engine and prevents the heat from leaving.
Removal of cooling passage blockages or cleaning of cooling fins is
considered “Normal Maintenance.” Any failure attributed to lack of
maintenance is not warranted.
INTAKE GRILL
Cleaning Grill and Cylinder Fins
1. Remove accumulated debris from intake grill between backpack
frame and blower housing.
2. Disconnect spark plug lead from spark plug.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
3. Remove spark plug
4. Remove engine cover - 7 screws.
5. Loosely install spark plug to keep dirt out of cylinder.
6. Clean cylinder fins to allow cooling air to pass freely.
7. Reassemble parts in reverse order.
IMPORTANT
Do not over-tighten screws, otherwise mounting holes may become
stripped.
EXHAUST SYSTEM
Spark Arrestor Screen
Level2.
Tools required: CrossHeadScrewdriver,4mmHexWrench,
Soft metal brush
Parts Required: Spark arrestor screen, Gasket
IMPORTANT
Carbon deposits in muffler will cause a drop in engine output and
overheating. Spark arrestor screen must be checked periodically.
1. Disconnect spark plug lead from spark plug.
2. Remove engine cover - 7 screws.
D
C
B
3. Remove exhaust deflector (A), spark arrestor cover (B), gasket (C),
and spark arrestor screen (D) from muffler. Replace screen if
plugged with carbon deposits.
A
NOTE
When cleaning carbon deposits, be careful not to damage the
catalyticelementinsidemuffler.
4. Install spark arrestor screen, gaskets, and covers.
5. Install engine cover.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
19
Cylinder Exhaust Port
Level3.
IMPORTANT
The cylinder exhaust port must be inspected and cleaned of excess
carbon every 3 months or 90 hours of operation in order to maintain
this engine within the emissions durability period. ECHO strongly
recommends that you return your unit to your ECHO dealer for this
important maintenance service.
CARBURETOR ADJUSTMENT
Level2.
Tools required: Screwdriver,tachometer(EchoP/N99051130017)
Parts required: None.
NOTE
Every unit is run at the factory and the carburetor is set in compli-
ance with Emission Regulations. This carburetor does not have
acceleration and high speed adjustment needles. Do not attempt to
use carburetor adjustment procedures provided in the Warranty
EmissionsBooklet.
BeforeAdjustment
Check that:
• Air filter is clean and properly installed.
• Spark arrestor screen is free of carbon.
• Blower pipes are installed.
A
1. Start engine, run at idle for one minute.
2. Complete warm up by running at full throttle for 5 minutes,
operating choke twice to clear air from carburetor chambers.
3. Check idle speed and reset if necessary. If a tachometer is
available, idle speed screw (A) should be set to the specifications
found on Page 22 "Specifications" of this manual. Turn idle screw
(A) clockwise to increase idle speed; counter clockwise to
decrease idle speed.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
TROUBLESHOOTING
TROUBLESHOOTING CHART
Problem
Check
Status
Cause
Remedy
Fuel strainer clogged
Fuel line clogged
Carburetor
Clean or replace
Clean or replace
See your Echo dealer
Fuel at carburetor
No fuel at carburetor
No fuel at cylinder
Carburetor
See your Echo dealer
Fuel Mixture too rich
Open choke
Fuel at cylinder
Engine
cranks -
starts hard/
doesn't
Clean/replace air filter
Adjust carburetor
See your Echo dealer
Muffler wet with fuel
No spark
Stop switch off
Electrical problem
Interlock switch
Turn switch to ON
See your Echo dealer
See your Echo dealer
start
Spark at end
of plug wire
Spark gap incorrect
Covered with carbon
Fouled with fuel
Adjust to .65mm (0.026 in.)
Clean or replace
Clean or replace
Spark at plug
No spark
Plug defective
Replace plug
Air filter
Air filter dirty
Normal wear
Clean or replace
Contaminants/residues in Replace
fuel
Fuel filter
Fuel filter dirty
Contaminants/residues in Clean or replace
fuel
Fuel vent
Fuel vent plugged
Engine runs,
but dies or
does not
accelerate
properly
Normal wear
Vibration
Clean and adjust or replace
Spark Plug
Carburetor
Plug dirty/worn
Adjust
Clean
Improper adjustment
Cooling system
dirty/plugged
Extended operation in
dirty/dusty locations
Cooling System
Spark Arrestor
Screen
Spark arrestor
screen plugged
Normal wear
Replace
Engine does
not crank
N/A
N/A
Internal engine problem
See your Echo dealer
Engine runs,
blower
doesn't work
or is
Build-up of debris
Vibration
Unclog
Tighten
Replace
Pipe clogged
Pipe loose
Blower pipe
Wear/Misuse
Pipe damaged
weak/uneven
WARNING
Fuel vapors are extremely flammable and may cause fire and/or explosion. Never test for ignition spark by grounding
spark plug near cylinder plug hole, otherwise serious personal injury may result.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
21
STORAGE
WARNING
During operation the muffler - catalytic muffler and surrounding cover become hot. Always keep exhaust area clear
of flammable debris during transportation or when storing, otherwise serious property damage or personal injury
may result.
Long Term Storage (Over 30 Days)
Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage mainte-
nance which includes the following:
1. Store unit in a dry, dust free place, out of the reach of children.
WARNING
Do not store where fuel fumes may accumulate or reach an open flame or spark.
2. Place the stop switch in the "STOP" position.
7. Remove the spark plug and pour 7cc (1/4 oz.) of
fresh, clean ECHO 2-stroke engine oil into the
cylinder through the spark plug hole.
3. Remove accumulation of grease, oil, dirt and debris
fromexteriorofunit.
A. Place a clean cloth over the spark plug hole.
4. Perform all periodic lubrication and services that are
required.
B. Pull the recoil starter handle 2-3 times to
distribute the oil inside the engine.
5. Tighten all screws and nuts.
C. Observe the piston location through the spark
6. Drain the fuel tank completely and pull the recoil
starter handle several times to remove fuel from the
carburetor.
plug hole. Pull the recoil handle slowly until the
piston reaches the top of its travel and leave it
there.
8. Install the spark plug (do not connect ignition cable).
9. Remove blower pipe assembly from unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
SPECIFICATIONS
MODEL ----------------------------------------------------- PB-265L
Length ------------------------------------------------------- 305mm(12.0in.)
Width-------------------------------------------------------- 410mm (16.1in.)
Height ------------------------------------------------------- 435mm(17.1in.)
Weight with pipes ----------------------------------------- 5.2 kg(11.5lb.)
Engine Type ------------------------------------------------ Air cooled, two-stroke, single cylinder gasoline engine
Displacement ----------------------------------------------- 25.4cc(1.55cu.in.)
Bore---------------------------------------------------------- 34.0cc(1.34in.)
Stroke-------------------------------------------------------- 28.0mm(1.10in.)
Carburetor -------------------------------------------------- Zama Diaphragm model w/purge bulb
Ignition System -------------------------------------------- Flywheel Magneto, capacitor discharge ignition type
SparkPlug -------------------------------------------------- NGKBPM8YGap0.65mm(0.026in.)
ExhaustSystem -------------------------------------------- Spark Arrestor Muffler w/Catalyst
Fuel ---------------------------------------------------------- Mixed(GasolineandTwo-strokeOil)
Fuel/OilRatio ----------------------------------------------- 50:1 two-stroke air cooled engine oil
Gasoline ----------------------------------------------------- 89 Octane unleaded. DO NOT use fuel containing methyl alcohol,
more than 10% ethyl alcohol or 15% MTBE.
Oil ------------------------------------------------------------ PowerBlendTM PremiumUniversal2-StrokeOil
Fuel Tank Capacity ---------------------------------------- 0.66lit.(22.3USfl.oz.)
RecoilStarterSystem -------------------------------------- i-30 Automatic Recoil Starter
Idle Speed --------------------------------------------------- 2,700-3,300 (RPM)
Wide Open Throttle Speed ------------------------------- 6,700-7,200(RPM)
Maximum Air Speed (Measured at pipe end) ---------- 59.1m/sec (132mph)
Average Air Volume (Measured at pipe end) ---------- 10.2m3/min.(361cu.ft./min.)
Sound Level at 50 ft. dB(A) scale per ANSI B175.2 ---- 65dB(A)
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
23
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INFORMATION
PARTS/SERIAL NUMBER
GenuineECHOPartsandECHOREPOWER™PartsandAssembliesfor
your ECHO products are available only from an Authorized ECHO
Dealer. When you do need to buy parts always have the Model
Number and Serial Number of the unit with you. You can find these
numbers on the engine housing. For future reference, write them in the
space provided below.
Model No. _____________ SN. ____________
SERVICE
Service of this product during the warranty period must be performed
by an Authorized ECHO Service Dealer. For the name and address of
the Authorized ECHO Service Dealer nearest you, ask your retailer or
call:1-800-432-ECHO(3246). Dealerinformationisalsoavailableonour
Web Site. When presenting your unit for Warranty service/repairs,
proof of purchase is required.
DEALER?
Call
1-800-432-ECHO
or
ECHO CONSUMER PRODUCT SUPPORT
If you require assistance or have questions concerning the application,
operation or maintenance of this product you may call the ECHO
ConsumerProductSupportDepartmentat1-800-673-1558from8:30am
to 4:30 pm (Central Standard Time) Monday through Friday. Before
calling, please know the model and serial number of your unit to help
your Consumer Product Support Representative.
CONSUMER PRODUCT
SUPPORT
1-800-673-1558
8:30 - 4:30 Mon - Fri C.S.T.
WARRANTY REGISTRATION
You may register your Echo equipment using the warranty registration
direct link between you and ECHO if we find it necessary to contact
you.
ADDITIONAL OR REPLACEMENT MANUALS
Safety Manuals in English/Spanish or English/French are available, free of charge, from your ECHO dealer or at
Operator'sandPartsManualsareavailableby:
• Downloadingfreefromwww.echo-usa.com
• Purchasing from your Echo Dealer.
• Manuals are available by sending a written request stating the model number and serial number of your Echo unit,
part number of the manual, your name and address, and mail to the address below.
Safety Videos are available from your Echo dealer. A $5.00 shipping charge will be required for each video.
ECHO, INCORPORATED
400OAKWOOD ROAD
LAKE ZURICH,IL 60047
09001001/09999999
Download from Www.Somanuals.com. All Manuals Search And Download.
|