Power Blower
Operator's Manual
MODEL
PB-230LN
Serial Number 003001001 & Up
WARNING
DANGER
Readrulesforsafeoperationandallinstructionscarefully. ECHOprovidesthisOperator's
Manualwhichmustbereadandunderstoodforproperandsafeoperation.
X750001870
08/00
X7501139500
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
3
MANUAL SAFETY SYMBOLS AND IMPORTANT INFORMATION
Throughout this manual and on the product itself, you will find safety
alerts and helpful, information messages preceded by symbols or key
words. The following is an explanation of those symbols and key
words and what they mean to you.
This symbol accompanied by the words WARN-
ING and DANGER calls attention to an act or
condition that can lead to serious personal injury to
operator and bystanders.
IMPORTANT Theenclosedmessage
provides information necessary for the
protection of the unit.
NOTE This enclosed message provides
tips for use, care and maintenance of the
unit.
The circle with the slash symbol means whatever is
shown within the circle is prohibited.
SAFETY
DECALS
HOT DECAL
Locate these safety decals on your unit. The complete unit illustra-
tion, found in the "DESCRIPTION" section, will help you locate
them. Make sure the decals are legible and that you understand and
follow the instructions on them. If a decal cannot be read, a new one
canbeorderedfromyourECHOdealer. SeePARTSORDERING
instructions for specific information.
P/N89016006361
P/N89016003360
Download from Www.Somanuals.com. All Manuals Search And Download.
4
INTERNATIONAL SYMBOLS
Symbol
description/application
Symbol
description/application
Symbol
Symbol
description/application
Symbol form/shape
Symbol form/shape
Symbol form/shape
Symbol form/shape
description/application
Ignition
ON/OFF
Read and understand
Operator's Manual.
Fuel and oil mixture
Finger Severing
Engine choke
control.
Wear eyes, ears and
head protection
Emergency stop
Primerbulb
Wear hand
protection.Use
two handed.
Hot
Surface
Carburetor adjustment
- High speed mixture
Carburetor adjustment
- Low speed mixture
Wearslip
resistant foot
wear.
Safety/Alert
Carburetor adjustment
- Idle speed
DO NOT allow
flamesorsparks
nearfuel.
DO NOT smoke
nearfuel.
EQUIPMENT
Before operation a complete check of the unit must be performed:
• Check unit for loose/missing nuts, bolts and screws. Tighten
and/or replace as needed.
• Inspect fuel lines, tank and area around carburetor for fuel leaks. DO
NOT operate unit if leaks are found.
Spark Arrestor - Catalytic Muffler / Muffler
• The muffler or catalytic muffler controls the exhaust noise and
emissions. The spark arrestor screen prevents hot, glowing particles
of carbon from leaving the muffler. Make sure the spark arrestor
screen is in good repair and properly seated in the muffler. Keep
exhaust area clear of flammable debris. Avoid contact during and
immediatelyafteroperation.
Parts
ATTACHMENTS
AND
• Do not use blower if any part is missing or damaged.
• Have repairs done only by an authorized ECHO Service dealer.
• Do not use any attachment, accessory or replacement part unless it is
recommended in this Operator's Manual.
ACCESSORIES
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
5
FUEL
WARNING
DANGER
FuelisVERYflammable.Useextremecarewhenmixing,storingor
handling or serious personal injury may result.
• Use an approved fuel container.
• DONOTsmokenearfuel.
• DO NOT allow flames or sparks near fuel.
• Fuel tanks/cans may be under pressure. Always loosen fuel caps
slowly allowing pressure to equalize.
• NEVER refuel a unit when the engine is HOT!
• NEVER refuel a unit with the engine running.
• DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks
outdoors over bare ground.
• Securely tighten fuel cap after refueling.
• Inspect for fuel leakage. If fuel leakage is found, do not start or
operate unit until leakage is repaired.
IMPORTANT
Spilled fuel is a leading cause of hydrocarbon emissions. Some
states may require the use of automatic fuel shut-off containers
to reduce fuel spillage. Contact your ECHO dealer for ordering
information.
After Refueling;
• Wipe any spilled fuel from the unit.
• Move at least 3 m (10 ft.) from refueling location before starting.
After use;
• DO NOT store a unit with fuel in its tank. Leaks can occur. Return
3 m
unused fuel to an approved fuel storage container.
(10'MINIMUM)
PERSONAL CONDITION AND SAFETY EQUIPMENT
WARNING
DANGER
Power Blower users risk injury to themselves and others if the Power Blower is used improperly and/or safety
precautions are not followed. Proper clothing and safety gear must be worn when operating a Power Blower.
Physical Condition --
Your judgment and physical dexterity may not be good:
• if you are tired or sick,
• if you are taking medication,
• if you have taken alcohol or drugs.
Operate unit only if you are physically and mentally well.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Eye Protection --
Wear eye protection that meets ANSI Z87.1 or CE requirements
whenever you operate the blower.
Hand Protection --
Wear no-slip, heavy duty work gloves to improve your grip on the
blower handle. Gloves also reduce the transmission of machine
vibration to your hands.
Breathing Protection --
Wear a face mask to protect against dust.
Hearing Protection --
ECHO recommends wearing hearing protection whenever unit is used.
Proper Clothing --
Wear snug fitting, durable clothing;
• Pants should have long legs, shirts with long sleeves.
• DONOTWEARSHORTS,
• DONOTWEARTIES,SCARVES,JEWELRY.
Wear sturdy work shoes with nonskid soles;
• DONOTWEAROPENTOEDSHOES,
• DONOTOPERATEUNITBAREFOOTED.
Keep long hair away from engine and blower intake. Retain hair with cap
or net.
Hot Humid Weather --
Heavy protective clothing can increase operator fatigue which may lead
to heat stroke. Schedule heavy work for early morning or late afternoon
hours when temperatures are cooler.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
7
SAFE OPERATION
Determine Operation Area --
•
•
•
Do not operate this product indoors or in inadequately ventilated
areas.
Review area to be cleared. Look for potential hazards such as stones
or metal objects.
Spectators and fellow workers must be warned, and children and
animals prevented from coming nearer than 15 m (50 ft.) while the
blower is in use.
•
•
Take wind conditions into account: avoid open doors and windows.
Provide all operators of this equipment with the Operator's Manual
and instructions for safe operation.
•
Do not point blower at people or animals.
UseProperClothing&Equipment
•
Before starting the unit, equip yourself and any other person
working within the 15 m (50 ft.) Safety Zone with the required
Protective Equipment and clothing.
•
•
Keep long hair away from engine and blower intake. Retain hair with
cap or net.
Start unit on ground with throttle at idle. Check that blower pipe is
not blocked by the ground or by any objects.
15 m
(50 ft.)
KeepASolidStance
•
Maintain footing and balance at all times. Do not stand on slippery,
uneven or unstable surfaces. Do not work in odd positions or on
ladders.
•
Do not perform Maintenance or Assembly procedures with engine
running.
NoiseControl
•
•
•
Follow local noise regulations on sound levels and hours of
operations. Use only during appropriate hours.
Never use a higher speed setting then necessary to perform a task.
The higher the engine speed the louder the blower noise.
Be a good neighbor.
AvoidHotSurfaces
•
During operation, the muffler or catalytic muffler and surrounding
cover may become extremely hot. Avoid contact during and immedi-
ately after operation. Always keep exhaust area clear of flammable
debris. Allow the engine and muffler to completely cool before
performing any maintenance activity.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
EXTENDED OPERATION/EXTREME CONDITIONS
Vibration and Cold --
It is believed that a condition called Raynaud’s Phenomenon, which
affects the fingers of certain individuals may be brought about by
exposure to vibration and cold. Exposure to vibration and cold may
cause tingling and burning sensations followed by loss of color and
numbness in the fingers. The following precautions are strongly
recommended because the minimum exposure which might trigger the
ailment is unknown.
•
•
•
Keep your body warm, especially the head, neck, feet, ankles, hands
and wrists.
Maintain good blood circulation by performing vigorous arm
exercises during frequent work breaks and also by not smoking.
Limit the hours of operation. Try to fill each day with jobs where
operating the blower or other hand-held power equipment is not
required.
•
If you experience discomfort, redness and swelling of the fingers
followed by whitening and loss of feeling, consult your physician
before further exposing yourself to cold and vibration.
Repetitive Stress Injuries --
It is believed that overusing the muscles and tendons of the fingers,
hands, arms and shoulders may cause soreness, swelling, numbness,
weakness and extreme pain in those areas. Certain repetitive hand
activities may put you at a high risk for developing a Repetitive Stress
Injury(RSI). AnextremeRSIconditionisCarpalTunnelSyndrome
(CTS), which could occur when your wrist swells and squeezes a vital
nerve that runs through the area. Some believe that prolonged exposure
to vibration may contribute to CTS. CTS can cause severe pain for
months or even years. To reduce the risk of RSI/CTS, do the following:
•
Avoid using your wrist in a bent, extended or twisted position.
Instead try to maintain a straight wrist position. Also, when
grasping, use your whole hand, not just the thumb and index finger.
Take periodic breaks to minimize repetition and rest your hands.
Reduce the speed & force in which you do the repetitive movement.
Do exercises to strengthen the hand and arm muscles.
Immediately stop using all power equipment and consult a doctor if
you feel tingling, numbness or pain in the fingers, hands, wrists or
arms. The sooner RSI/CTS is diagnosed, the more likely permanent
nerve and muscle damage can be prevented.
•
•
•
•
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
9
DESCRIPTION
EMISSION CONTROL
EMISSION CONTROL
Refer to Emission Control Label on engine to determine
EPA Phase I or EPA Phase II compliance.
EPA Phase II
The emission control system for these engines are EM
(EngineModification).
EPA Phase I
The emission control system for these engines are
EM(EngineModification).
IMPORTANTENGINEINFORMATION
ENGINE FAMILY: YEHXS.0254CB
DISPLACEMENT: 22.8 CC
THIS ENGINE MEETS U.S. EPA PHASE II EMISSION
REGULATIONS FOR S.O.R.E. REFER TO OWNER'S
MANUAL FOR MAINTENANCE SPECIFICATIONS AND
ADJUSTMENTS. EMISSION COMPLIANCE PERIOD : 300
HRS.
IMPORTANT ENGINE INFORMATION
ENGINE FAMILY : YEHXS.0254CB
DISPLACEMENT : 22.8 cc
THIS ENGINE MEETS U.S. EPA PHI EMISSION REGULA-
TIONS FOR ULGE ENGINES. REFER TO OWNER’S
MANUAL FOR MAINTENANCE SPECIFICATIONS AND
ADJUSTMENTS.
An Emission Control Label is located on the engine.
(ThisisanEXAMPLEONLY,informationonlabelvaries
byengineFAMILY).
An Emission Control Label is located on the engine.
(ThisisanEXAMPLEONLY,informationonlabelvaries
byengineFAMILY).
PRODUCT EMISSION DURABILITY
The 300 hour emission durability period is the time
span selected by the manufacturer certifying the
engine emissions output meets applicable EPA
emissions regulations, provided that approved
maintenance procedures are followed as listed in the
Maintenance Section of this manual.
CONTENTS
1 - Power Head
1 - Blower Pipe Assembly
1 - Operator's Manual
1 - Warranty Registration Card
1 - ECHO Emissions and Warranty Statement
1-BottleECHO2-StrokeOilMix
Download from Www.Somanuals.com. All Manuals Search And Download.
10
1
9
11
2
3
4
5
6
10
7
8
1. STOP SWITCH - "SLIDE SWITCH" mounted on top of handle. Push forward to start and run. Slide back to stop.
2. THROTTLETRIGGER-Springloadedtoreturntoidlewhenreleased. Duringacceleration, presstriggergradually
for best operating technique.
3. SPARKPLUG-Providessparktoignitefuelmixture.
4. CHOKE - Choke is located on top of the air cleaner. Move choke lever to "COLD START" to close choke for cold
start. Move choke lever to "RUN" position to open choke.
5. SPARKARRESTOR-CATALYTICMUFFLER/MUFFLER-Themufflerorcatalyticmufflercontrolsexhaustnoise
and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep
exhaust area clear of flammable debris.
6. RECOILSTARTERHANDLE-Pullrecoilhandleslowlyuntilrecoilstarterengages,thenquicklyandfirmly. When
engine starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur.
7. FUELTANKCAP-Coversandsealsfueltank.
8. AIRCLEANER-Containsreplaceableairfilterelement.
9. THROTTLEPOSITIONLEVER-Pullbacktoincreaseenginespeed.Frictionwashersmaintainthrottlelever
setting.
10. PRIMER BULB - Pumping primer bulb before starting engine draws fresh fuel from the fuel tank priming the
carburetor for starting. Pump primer bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump
bulb an additional 4 or 5 times.
11. BLOWERPIPES-Twistlockdesign.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
11
SPECIFICATIONS
MODEL
PB-230LN Hand Held
Length
335 mm (13.2 in.) (w/o pipes)
235 mm (9.3 in.)
Width
Height
375 mm (14.8 in.)
Weight (dry)
Engine Type
Displacement
Bore
4.6 kg (10.1lb.)
Air cooled, two-stroke, single cylinder gasoline engine
22.8 cc (1.39 cu. in.)
32.2 mm (1.27 in.)
Stroke
28.0 mm (1.10 in.)
Carburetor
Ignition System
Spark Plug
Exhaust System
Fuel
Zama Diaphragm, model RB w/primer bulb
Flywheel Magneto, capacitor discharge ignition type
NGK BPM-7Y Gap 0.65 mm (0.026 in.)
Spark Arrestor Muffler
Mixed (Gasoline and Two-stroke Oil)
50:1 ECHO High Performance, two-stroke air cooled engine oil
Fuel/Oil Ratio
Gasoline
89 Octane unleaded. DO NOT use fuel containing methyl alcohol, more
than 10% ethyl alcohol or 15% MTBE.
Oil
50:1 ECHO High Performance, two-stroke air cooled engine oil
0.6 lit. (20.3 US fl. oz.)
Fuel Tank Capacity
Recoil Starter System
Wide Open Throttle Speed (RPM)
Idle Speed (RPM)
Automatic Recoil Starter Centrifugal Type
7000 - 7400
2500 - 3000
Maximum Air Volume
Maximum Air Speed w/pipes (MPH)
9.4 m3/min. (332 cu. ft./min.)
66 m/sec (147.6 mph)
Sound Level at 50 ft. dB(A) scale per
ANSI B175.2
66 dB(A)
Download from Www.Somanuals.com. All Manuals Search And Download.
12
ASSEMBLY
WARNING
DANGER
Never perform maintenance or assembly procedures with engine
running or serious personal injury may result.
BLOWER APPLICATION
Install Blower Pipes
1. Align grooves in straight pipe with pegs on blower housing and
slide pipe onto housing.
2. Turn straight pipe clockwise to lock into place.
3. Align grooves in fan head nozzle with pegs on straight pipe and
slide fan head nozzle onto straight pipe.
4. Turn fan head nozzle clockwise to lock into place.
PRE-OPERATION
FUEL
Fuel Requirements
Gasoline - Use 89 Octane [R + M] (mid grade or higher) gasoline known
2
to be good quality. Gasoline may contain up to 15% MTBE (methyl
tertiary-butyl ether). Gasohol containing methyl (wood) alcohol is NOT
approved.
TwoStrokeOil-Atwo-strokeengineoilmeetingISO-L-EGD(ISO/CD
13738) and J.A.S.O. FC Standards, must be used. Echo brand Premium
50:1 oil meets these standards. Engine problems due to inadequate
lubrication caused by failure to use an ISO-L-EGD and J.A.S.O. FC
certifiedoil, suchasEchoPremium50:1Two-strokeOil, willvoidthe
two-stroke engine warranty. (Emission related parts only are covered
for two years, regardless of two-stroke oil used, per the statement listed
in the EPA Phase II Emission Defect Warranty Explanation.)
IMPORTANT
EchoPremium2-StrokeOilmaybemixedat50:1ratioforapplica-
tion in all Echo engines sold in the past regardless of ratio
specified in those manuals.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
13
Mixing Instructions
1. Fill an approved fuel container with half of the required amount of
gasoline.
2. Add 2-stroke oil to gasoline.
3. Close container and shake to mix oil with gasoline.
4. Addremaininggasolineandremix.
5. Install fuel container cap and wipe any spilled fuel from container
and surrounding area.
Handling Fuel
WARNING
DANGER
FuelisVERYflammable.Useextremecarewhenmixing,storingor
handling or serious personal injury may result.
• Use an approved fuel container.
• DONOTsmokenearfuel.
• DO NOT allow flames or sparks near fuel.
• Fuel tanks/cans may be under pressure. Always loosen fuel
caps slowly allowing pressure to equalize.
• NEVER refuel a unit when the engine is HOT!
• NEVER refuel a unit with the engine running.
• DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks
outdoors over bare ground.
• Securely tighten fuel cap after refueling.
• Inspect for fuel leakage. If fuel leakage is found, do not start or
operate unit until leakage is repaired.
IMPORTANT
Spilled fuel is a leading cause of hydrocarbon emissions. Some
states may require the use of automatic fuel shut-off containers
to reduce fuel spillage. Contact your ECHO dealer for ordering
information.
After Refueling -
•
Wipe any spilled fuel from the unit.
•
Move at least 3m (10 ft.) from refueling location before starting.
After use -
•
DO NOT store a unit with fuel in its tank. Leaks can occur. Return
unused fuel to an approved fuel storage container.
3m
10 ft. MINIMUM
Storage -
Fuel storage laws vary by locality. Contact your local government for
the laws affecting your area. As a precaution, store fuel in an approved,
air tight container. Store in a well ventilated, unoccupied building, away
from sparks and flames. Do not store fuel longer than 30 days.
S M T W T F
S
7
1
8
2
3
4 5 6
9 10 11 12 13 14
IMPORTANT
Stored fuel ages. Do not mix more fuel than you expect to use in
thirty (30) days, ninety (90) days when a fuel stabilizer is added.
15 16 17 18 19 20 21
22 23 24 25 26 27 28
29 30 31
Stored two-stroke fuel may separate. ALWAYS shake fuel con-
tainer thoroughly before each use.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
OPERATION
• Provide all operators of this equipment with the Operator's Manual
and instructions for safe operation.
15 m
(50 ft.)
• Before starting the unit, equip yourself and any other person working
within the 15 m (50 ft.) Safety Zone with the required Protective
Equipment and clothing.
• Do not operate this product indoors or in inadequately ventilated
areas.
STARTING COLD ENGINE
1. Stop Switch - Start/Run.
A
Move stop switch button (A) away from the STOP position.
B
2. Move throttle position lever (B) midway between idle and full
throttle positions.
3. Close Choke - Cold Start.
C
Move choke (C) to "Cold Start" Position.
4. PurgeBulb-Pump.
Pump primer bulb (C) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope for starting.
Do not allow the rope to snap back in. Always hold the unit
firmly.
D
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
15
5. Place the blower on a flat clear area. Firmly grasp throttle grip with
left hand and rapidly pull recoil starter handle/rope (E) until engine
fires.
6. After engine fires, move choke lever to “Run” position and pull
recoil starter handle/rope until engine starts and runs. Allow unit
to warm up at idle for several minutes.
NOTE
If engine does not start with choke in “Run” position after 4 pulls,
repeat instructions.
E
7. After engine warm up, gradually depress throttle trigger to
increase engine RPM to operating speed.
STARTING WARM ENGINE
A
1. Stop Switch - Start/Run. Move stop switch button (A) away from
B
the STOP position.
2. Move throttle position lever (B) forward to idle position.
3. Place the blower on a flat clear area. Firmly grasp throttle grip with
left hand and rapidly pull recoil starter handle/rope (E) until engine
fires.
IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope for starting.
Do not allow the rope to snap back in. Always hold the unit
firmly.
NOTE
If engine does not start after 4 pulls, use Cold Start Procedure.
STOPPING ENGINE
A
F
1. Release throttle trigger (F) and allow engine to idle for a minute.
2. Move stop switch (A) to "STOP" position.
WARNING
DANGER
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using blower
again.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
OPERATING BLOWER
B
WARNING
DANGER
Always wear safety glasses, hearing protection and a face filter
mask or serious personal injury may result. .
Do not point the blower pipe in the direction of people or pets.
Read the Safety Section carefully.
IMPORTANT
To avoid engine damage due to over revving, do not block
blowerpipe.
1. Use only during appropriate hours.
2. Allow the engine to warm up at a fast idle for a few minutes.
3. Set engine speed with throttle position lever (B). Rotate lever
forward for lower speed; back for higher speed.
4. Use lower speed to blow dry leaves from a lawn or flower bed.
Additional speed may be necessary to clean grass and leaves from
walks, patios and drives or to move gravel, dirt, snow, bottles or
cans from a driveway, street, parking lot or stadium.
NOTE
Never use a higher speed setting than necessary to perform a task.
Remember, the higher the engine speed, the louder the blower noise.
Minimize dust by using blower at lower speeds. Keep debris on
your property.
Be Smart - be a good neighbor.
Download from Www.Somanuals.com. All Manuals Search And Download.
SOPLADOR MOTORIZADO
MANUAL DEL OPERADOR
17
MANTENIMIENTO
Su soplador ECHO está diseñado para proporcionar muchas horas de servicio sin problemas. El mantenimiento
programado regular permitirá que el soplador alcance ese objetivo. Si no está seguro o no dispone de las herramientas
necesarias, puede llevar la máquina a su distribuidor de servicio ECHO para el mantenimiento. Se ha clasificado cada tarea
de mantenimiento para que decida si desea hacer el mantenimiento USTED o el distribuidor de ECHO. Si la tarea no está
indicada vea a su distribuidor ECHO para efectuar las reparaciones.
NIVEL DE HABILIDAD
Nivel 1 =
Nivel 2 =
Nivel 3 =
Fácil de hacer. La mayoría de las herramientas vienen con la unidad.
Dificultad moderada. Tal vez se necesiten algunas herramientas especializadas.
Se requiere experiencia. Se requieren herramientas especializadas. Echo recomienda devolver la unidad a
su distribuidor ECHO para efectuar el servicio de la misma.
ECHO ofrece juegos de mantenimiento y piezas REPOWER™para facilitar su trabajo de mantenimiento. Debajo de cada
título de tarea se indican los distintos números de pieza necesarios para dicha tarea. Consulte con su distribuidor en lo
que se refiere a esas piezas.
INTERVALOS DE MANTENIMIENTO
Necesarias
nivel de
habilidad
Diaiamente
o Antes de
usar
3 meses
o 90
horas
6 meses
o 270
horas
Componente/
Sistema
Procedimiento de
Mantenimiento
Al cargar
combustible
Anualmente
Procedimientos De Mantenimiento Recomendados Del Distribuidor Echo
Orificio de escape del
cilindro
Inspeccionar/Limpiar/
Descarbonizar
3
I / L
R*
I
Procedimientos De Mantenimiento De Do-It-Yourself
Filtro de aire
Estrangulador
Inspeccionar/ Limpiar/
Reemplazar
1
I / L
I / L
Inspeccionar/Limpiar
2
1
Filtro de
combustible
Inspeccionar/Reemplazar
R*
Sistema de
combustible, Fugas
Inspeccionar/Reemplazar
Inspeccionar/Limpiar
Inspeccionar/Reemplazar
Inspeccionar/Limpiar
Inspeccionar/Limpiar
1
2
2
1
I
I / R*
Sistema de
enfriamiento
I / L
Apagachispas del
silenciador
I / R*
Cuerda del motor de
arranque
I / L
I / R*
Bujía
2
1
I / L
R*
Tornillos/Tuercas/
Pernos
Inspeccionar/Apretar/
Reemplazar
I / R*
CÓDIGOS DE LETRAS DEL PROCEDIMIENTO DE M MANTENIMIENTO: I NSPECCIONAR, R = REEMPLAZAR, L = LIMPIAR
NOTA IMPORTANTE - Los intervalos indicados son máximos. El uso real y su experiencia determinarán la frecuencia del mantenimiento
requerido.
NOTAS DE PROCEDIMIENTOS DE MANTENIMIENTO:
* Todas las recomendaciones de reemplazo se basan en encontrar piezas dañadas o desgastadas durante la inspección.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
AIR FILTER
Level1.
Tools required: 25-50 mm (1-2 in.) medium bristle paint brush.
Parts required: 90030 REPOWERTM Air and Fuel Filter Kit
NOTE
Cleandaily.
1. Close choke (Cold Start Position). This prevents dirt from
entering the carburetor throat when the air filter is removed.
Brush accumulated dirt from the air cleaner area.
2. Remove the air cleaner cover. Clean and inspect the element for
damage. If element is fuel soaked and very dirty, replace.
3. If element can be cleaned and reused, be certain it:
•still fits the cavity in the air cleaner cover.
•is installed with the original side out.
FUEL FILTER
Level1.
Toolsrequired: Fuellinehook. 203-254mm(8-10in.)lengthofwirewith
one end bent into a hook. Clean rag, funnel, and an approved fuel
container.
Partsrequired: 90030REPOWERTM AirandFilterKit
WARNING
DANGER
FuelisVERYflammable.Useextremecarewhenmixing,storingor
handling.
1. Use a clean rag to remove loose dirt from around fuel cap and
empty fuel tank.
2. Use the “fuel line hook” to pull the fuel line and filter from the
tank.
3. Remove the filter from the line and install the new filter.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
19
WARNING
DANGER
Do not perform maintenance on the engine or muffler until engine
and muffler are completely cool, otherwise serious personal injury
may occur.
SPARK PLUG
Level2.
Tools required: 3/4 in. Spark Plug deep socket, Feeler gauge (preferably
a wire gauge),
PartsRequired: 90065REPOWERTM Tune-UpKit
1. Remove spark plug and check for fouling, worn and rounded
center electrode.
2. Clean the plug or replace with a new one. DO NOT sand blast to
clean. Remaining sand will damage engine.
3. Adjust spark plug gap by bending outer electrode.
4. Tightensparkplugto145-155kg/cm(125-135in.lb.).
COOLING SYSTEMS CLEANING
Level2.
Toolsrequired: 25-50mm(1-2in.)mediumbristlebrush,3mmHex
Wrench, Cross Head Screwdriver.
Parts Required: None, if you are careful.
IMPORTANT
To maintain proper engine operating temperatures, cooling air must
pass freely through the cylinder fin area. This flow of air carries
combustion heat away from the engine.
INTAKE
GRILL
Overheating and engine seizure can occur when:
• Air intakes are blocked, preventing cooling air from reaching the
cylinder.
• Dust and grass build up on the outside of the cylinder. This build up
insulates the engine and prevents the heat from leaving.
Removal of cooling passage blockages or cleaning of cooling fins is
considered “Normal Maintenance”. Any failure attributed to lack of
maintenance is not warranted.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Cleaning Grill
1. Brush accumulated debris from crankcase intake grille above the
fueltank.
Cleaning Cylinder Fins
1. Remove two upper 3 mm hex screws at recoil starter.
2. Remove four engine cover screws and remove cover from engine.
Clean cylinder fins to allow cooling air to pass freely.
3. Loosely reassemble engine cover with four cross head and two
hex head screws.
4. Tighten all screws securely.
EXHAUST SYSTEM
Spark Arrestor Screen
Level2.
Tools required: Cross Head Screwdriver, 3mm Hex Wrench, 25-50 mm
(1-2in.)mediumbristlebrush
PartsRequired: SparkarrestorscreenP/N14586240630,
(1ea.)GasketsP/NV104000030,V104000050
IMPORTANT
Carbon deposits in muffler will cause a drop in engine output and
overheating. Spark arrestor screen must be checked periodically.
1. Remove two upper 3 mm hex screws at recoil starter.
2. Remove four engine cover screws and remove cover from engine.
Clean cylinder fins with brush to allow cooling air to pass freely.
3. Remove spark arrestor cover (A), gaskets (B) and (C) and spark
arrestor screen (D) from muffler. Replace screen if plugged with
carbon deposits.
D
C
B
4. Install spark arrestor screen, gaskets, and cover.
5. Loosely reassemble engine cover with four cross head and two
hex head screws.
A
6. Tighten all screws securely.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
21
Cylinder Exhaust Port
Level3.
IMPORTANT
The cylinder exhaust port must be inspected and cleaned of excess
carbon every 3 months or 90 hours of operation in order to maintain
this engine within the emissions durability period. ECHO strongly
recommends that you return your unit to your ECHO dealer for this
important maintenance service.
CARBURETOR ADJUSTMENT
Engine Break-In
New engines must be operated a minimum duration of two tanks of fuel
break-in before carburetor adjustments can be made. During the break-in
period your engine performance will increase and exhaust emissions will
stabilize. Idle speed can be adjusted as required.
High Altitude Adjustment
High altitude adjustment is not required for proper operation of this
engine.
Level2.
Toolsrequired: Screwdriver,tachometer(EchoP/N99051130017)
Parts required: none.
NOTE
Every unit is run at the factory and the carburetor is set in compli-
ance with EPA Emission Regulations. This carburetor does not have
acceleration and high speed adjustment needles.
A
IdleAdjustment
Before adjustment make sure that:
• Air filter is clean and properly installed.
• Spark arrestor screen is free of carbon.
• Blower pipes are installed.
A
1. Start engine, run at idle for one minute.
2. Complete warm up by running at full throttle for 5 minutes,
operating choke twice to clear air from carburetor chambers.
3. Check idle speed and reset if necessary. If a tachometer is
available, idle speed screw (A) should be set to the specifications
found on Page 11 "Specifications" of this manual. Turn idle screw
(A) clockwise to increase idle speed; counter clockwise to
decrease idle speed.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
TROUBLESHOOTING
Problem
Engine - starts hard
Engine - does not start
Cause
Remedy
Engine
Cranks
Fuel at
carburetor
No fuel at
carburetor
Fuel strainer clogged
Fuel line clogged
Carburetor
Clean
Clean
See your ECHO dealer
Fuel at
cylinder
No fuel at
cylinder
Carburetor
See your ECHO dealer
Muffler wet Fuel Mixture is too rich
with fuel
Open choke
Clean/replace air filter
Adjust carburetor
See your ECHO dealer
Spark at end
of plug wire
No spark
at end of
plug wire
Stop switch off
Electrical problem
Turn switch on
See your ECHO dealer
Spark at plug
No spark
at plug
Spark gap incorrect
Covered with carbon
Fouled with fuel
Adjust 0.65mm (0.026in.)
Clean or replace
Clean or replace
Replace plug
Spark plug defective
Engine
does not
crank
Internal engine problem
See your ECHO dealer
Engine
runs
Dies or accelerates poorly
Air filter dirty
Clean or replace
Replace
Replace
Clean and adjust/replace
Adjust
Fuel filter dirty
Fuel vent plugged
Spark plug
Carburetor
Cooling system plugged
Clean
Spark arrestor screen plugged Clean
Engine
runs
Blower does not work,
is weak or uneven.
Blower pipe clogged, loose,
or damaged.
Unclog
Tighten
properly
WARNING
DANGER
Fuel vapors are extremely flammable and may cause fire and/or explosion. Never test for ignition spark by ground-
ing spark plug against cylinder, otherwise serious personal injury may result.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER BLOWER
OPERATOR'S MANUAL
23
STORAGE
WARNING
DANGER
During operation the muffler or catalytic muffler and surrounding cover becomes hot. Always keep exhaust area
clear of flammable debris during transportation or when storing, otherwise serious property damage or personal
injury may result.
Long Term Storage (Over 30 Days)
Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage mainte-
nance which includes the following:
1. Store unit in a dry, dust free place, out of the reach of children.
WARNING
DANGER
Do not store where fuel fumes may accumulate or reach an open
flameorspark.
A
2. Place the stop switch (A) in the "STOP" position.
3. Remove accumulation of grease, oil, dirt and debris from exterior of
unit.
4. Perform all periodic lubrication and services that are required.
5. Tighten all screws and nuts.
6. Drain the fuel tank completely and pull the recoil starter handle
several times to remove fuel from the carburetor.
7. Remove the spark plug and pour 7cc (1/4 oz., 1/2 tablespoon) of
fresh, clean ECHO 2-stroke engine oil into the cylinder through
the spark plug hole.
A. Place a clean cloth over the spark plug hole.
B. Pull the recoil starter handle 2-3 times to distribute the oil
inside the engine.
C. Observe the piston location through the spark plug hole.
Pull the recoil handle slowly until the piston reaches the top
of its travel and leave it there.
8. Install the spark plug (do not connect ignition cable).
9. Remove blower pipe assembly from unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INFORMATION
PARTS
GenuineECHOPartsandECHOREPOWER™PartsandAssembliesfor
your ECHO products are available only from an Authorized ECHO
Dealer. When you do need to buy parts always have the Model
Number and Serial Number of the unit with you. You can find these
numbers on the engine housing. For future reference, write them in the
space provided below.
Model No. _____________ SN. ____________
SERVICE
DEALER?
Call
1-800-432-ECHO
or
Service of this product during the warranty period must be performed
by an Authorized ECHO Service Dealer. For the name and address of
the Authorized ECHO Service Dealer nearest you, ask your retailer or
call:1-800-432-ECHO(3246). Dealerinformationisalsoavailableonour
Web Site. When presenting your unit for Warranty service/repairs,
proof of purchase is required.
ECHO CONSUMER PRODUCT SUPPORT
CONSUMER PRODUCT
SUPPORT
If you require assistance or have questions concerning the application,
operation or maintenance of this product you may call the ECHO
ConsumerProductSupportDepartmentat1-800-673-1558from8:00am
to 5:00 pm (Central Standard Time) Monday through Friday. Before
calling, please know the model and serial number of your unit to help
your Consumer Product Support Representative.
1-800-673-1558
8 - 5 Mon - Fri C.S.T.
WARRANTY REGISTRATION
You may register your Echo equipment using the warranty registration
direct link between you and ECHO if we find it necessary to contact
you.
ADDITIONAL OR REPLACEMENT MANUALS
Safety Manuals in English/Spanish or English/French are available, free of charge, from your ECHO dealer or at
Operator'sandPartsManualsareavailableby:
•
•
•
Downloadingfreefromwww.echo-usa.com
Purchasing from your Echo Dealer.
Sending a check or money order for $2.00 per Parts Catalog or $1.50 per Operator's Manual made payable to ECHO,
INCORPORATED. State on a sheet of paper the model number and serial number of the ECHO unit you have, part
number of the manual (if known), your name and address and mail to address above.
Safety Videos are available from your Echo dealer. A $5.00 shipping charge will be required for each video.
Available Parts Catalog
PB-230LNS/N003001001&UP
PartNumber99922203230
ECHO, INCORPORATED
400OAKWOOD ROAD
LAKE ZURICH,IL 60047
Download from Www.Somanuals.com. All Manuals Search And Download.
|