Installation
Instructions
30", 36" and 48"
Professional
Restaurant Style
Vent Hoods
Models:
ZV48R
ZV36R
ZV30R
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CONTENTS
Step 1, Determine Ductwork and Wiring Locations .... 10
Step 2A, Install Hood Onto Wall ................................... 11
Step 2B, Install Hood Beneath Soffit ............................ 12
Step 3, Connect Ductwork ............................................. 13
Step 4, Connect Electrical.............................................. 13
Step 5, Install Duct Covers ............................................. 13
Step 6, Install Motor ....................................................... 13
Step 7, Install Filters ....................................................... 14
Step 8, Install Backguard and Shelf............................... 14
Step 9, Install Shelf Only................................................ 15
Step 10, Install Implement Rods ................................... 15
Product Dimensions ......................................................... 3
Installation Clearances ..................................................... 4
Optional Duct Cover Accessories .................................... 4
Installation Height, Duct Cover Accessories................... 5
Advance Planning ............................................................. 6
Power Supply .................................................................... 6
Duct Fittings...................................................................... 7
Tools and Materials Required .......................................... 8
Remove the Packaging ..................................................... 8
Parts Provided ................................................................... 9
PRODUCT DIMENSIONS
12"
47-15/16"
Each hood is
shipped with a
stainless steel
10"
backguard and a
warming shelf.
Hoods may be
installed with the
shelf or backguard
alone, or with both
as shown.
Warming
Shelf
22-1/2"
Backguard
47-15/16"
25"
Model ZV48R
12"
35-15/16"
29-15/16"
12"
10"
10"
22-1/2"
22-1/2"
29-15/16"
35-15/16"
25"
25"
Model ZV36R
Model ZV30R
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Advance Planning
INSTALLATION CLEARANCES
OPTIONAL DUCT COVER
ACCESSORIES
These vent hoods are designed to be installed onto a
wall or beneath a soffit or cabinet.
Standard and Full-Width decorative duct covers are
available in 6" and 12" heights. Duct covers may be
stacked, in various combinations, to conceal the
ductwork running from the top of the hood to the
ceiling.
Installation with Warming Shelf
•Hoods must be installed 32" Min., 38" Max over any
type cooking surface when warming shelf is used.
Installation without Warming Shelf
•Install these hoods 30" Min. to 36" Max. above the
cooking surface when installed over any professional
style cooktop or range.
• Before you begin, you should determine the
installation height of the hood and order the correct
size duct cover. The duct covers should be ordered at
the same time as the vent hood and be on site before
installation. Order the duct cover corresponding to
your model.
•These hoods may be installed 24" min. above a gas or
electric drop-in style cooktop.
Note: Clearances may vary due to type of cooking product and
local codes. Check with local inspectors to be sure standard is
applicable.
Standard Duct Covers
6" Duct Cover
Soffit Installation
12" Duct Cover
SOFFIT
SOFFIT
6" Duct Covers
Hood Model
ZV48R
ZV36R
6” Duct Cover
ZX48DC6
ZX36DC6
Dimensions
30" Min.
36" Max.
32" Min.
38" Max.
6"H x 19-11/16"W x 11-7/8"D
6"H x 15-3/4"W x 11-7/8"D
6"H x 15-3/4"W x 11-7/8"D
ZV30R
ZX36DC6
Allow 32" min. and 38" max.
clearance above any cooking
surface when installed with shelf.
Install these hoods 30" Min. to
36" Max. over a professional
style cooktop or range.
12" Duct Covers
Hood Model
ZV48R
ZV36R
ZV30R
12” Duct Cover Dimensions
ZX48DC12
ZX36DC12
ZX36DC12
12"H x 19-11/16"W x 11-7/8"D
12"H x 15-3/4"W x 11-7/8"D
12"H x 15-3/4"W x 11-7/8"D
In this installation, the ductwork running from the
top of the hood will be concealed in the soffit or
upper cabinetry.
Full-Width Duct Covers
Wall Mount Installation
Optional 6"
or 12" Duct
Cover
30" Min.
36" Max.
32" Min.
38" Max.
6" Duct Covers
Hood Model
ZV48R
ZV36R
ZV30R
6” Duct Cover
Dimensions
ZX48FWDC6
ZX36FWDC6
ZX30FWDC6
6"H x 47-15/16"W x 11-7/8"D
6"H x 35-15/16"W x 11-7/8"D
6"H x 29-15/16"W x 11-7/8"D
Allow 32" min. and 38" max.
clearance above any cooking
surface when installed with shelf.
Install these hoods 30" Min. to
36" Max. over a professional
style cooktop or range.
12" Duct Covers
Hood Model
ZV48R
ZV36R
ZV30R
12” Duct Cover Dimensions
For this installation, a decorative duct cover is
available to conceal the ductwork running from
the top of the hood. Use of the duct cover requires
special consideration to the installation height above
the countertop.
ZX48FWDC12
ZX36FWDC12
ZX30FWDC12
12"H x 47-15/16"W x 11-7/8"D
12"H x 35-15/16"W x 11-7/8"D
12"H x 29-15/16"W x 11-7/8"D
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Advance Planning
DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES
These vent hoods must be installed 30" min. to
36" max. above the standard 36" high cooking
surface. When installed with the warming shelf,
allow 32" min. to 38" max. clearance. The exact
hood installation height is determined by the
ceiling height.
Restaurant-Style Hoods
without Warming Shelf Installed
Restaurant-Style Hoods
with Shelf Installed1
*Possible
Hood
*Possible
Hood
Actual
Ceiling Installation 6" Duct 12" Duct Installation 6" Duct 12" Duct
Height
Height
Covers Covers
Height
Covers Covers
7' 11"
31"
1
1
1
1
37"
1
1. Measure the exact ceiling height.
2. Review the chart at right to determine the
range of possible hood installation heights that
can be accomplished with one or more duct
covers.
3. Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct covers.
4. Duct covers may be stacked, in various
combinations, to reach ceiling heights.
8' 0"
8' 0"
32"
32"
38"
1
1
1
8' 1"
8' 2"
8' 3"
33"
34"
35"
1
1
1
1
1
1
33"
34"
35"
1
1
1
1
1
1
8' 4"
8' 4"
30"
36"
2
1
1
36"
37"
1
1
1
1
8' 5"
31"
32"
2
2
8' 6"
8' 6"
32"
38"
2
1
Duct Cover(s)
Duct Cover(s)
10"
1
10"
8' 7"
8' 8"
8' 9"
33"
34"
35"
2
2
2
33"
34"
35"
2
2
2
30" Min.
36" Max.
32" Min.
38" Max.
8' 10"
8' 10"
30"
36"
1
2
2
36"
37"
2
2
8' 11"
31"
32"
1
1
2
2
9' 0"
9' 0"
32"
38"
1
2
2
Ceiling
Height
to Floor
Ceiling
Height
to Floor
9' 1"
9' 2"
9' 3"
33"
34"
35"
1
1
1
2
2
2
33"
34"
35"
1
1
1
2
2
2
9' 4"
9' 4"
30"
36"
3
2
1
36"
37"
1
1
2
2
Note: When determining the installation height, consideration
must be given to the use of the warming shelf.
9' 5"
31"
32"
3
3
9' 6"
9' 6"
32"
38"
3
2
1
9' 7"
9' 8"
9' 9"
33"
34"
35"
3
3
3
33"
34"
35"
3
3
3
9' 10"
9' 10"
30"
36"
1
3
3
36"
37"
3
3
9' 11"
31"
32"
1
1
3
3
10' 0"
10' 0"
32"
38"
1
3
3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Advance Planning
ADVANCE PLANNING
POWER SUPPLY
IMPORTANT – (Please read carefully)
Ductwork Planning
•These vent hoods are equipped for 10" round
ductwork. For best performance, use 10" round
ductwork on the 48" wide hoods. 30" and 36" hoods
may be transitioned to 8" round.
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
•This hood may be vented vertically through upper
cabinets, soffit or ceiling. A duct transition piece is
supplied for vertical exhaust. Use locally supplied
elbows to vent horizontally through the rear wall.
•Determine the exact location of the vent hood.
•Plan the route for venting exhaust to the outdoors.
•Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should
not exceed 150 ft. equivalent length for any duct
configurations.
AVERTISSEMENT–
POUR DES
RAISONS DE SÉCURITÉ, CET APPAREIL DOIT
ÊTRE CORRECTEMENT MIS À LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
•Refer to “Duct Fittings” chart to compute the
maximum permissible length for duct runs to the
outdoors.
•Use metal ductwork only.
Electrical supply
•Install a wall cap or roof cap with damper at the
exterior opening. Order the wall or roof cap and any
transition needed in advance.
These vent hoods must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
Wall Framing for Adequate Support
•These vent hoods are heavy. Adequate structural
support must be provided. Hoods must be secured to
vertical studs in the wall.
•It is strongly recommend that the vent hood with
duct cover be on site before final framing and wall
finishing. This will also help to accurately locate the
ductwork and electrical service.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible on the back wall or ceiling.
• Connect the wiring to the house wiring in
accordance with local codes.
Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available
to fit all models. The duct cover conceals the ductwork
running from the top of the hood to the ceiling or
soffit. Stack one or more duct covers over the top
of the hood to reach your ceiling height.
Grounding instructions
The grounding conductor must be connected
to a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING:
The improper connection of
the equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil de mise à la terre peut
causer un choc électrique. En cas de doute, consulter
un électricien qualifié ou un technicien pour
déterminer si l’appareil est à la terre.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Advance Planning
Equivalent Quantity
Total
Length
DUCT FITTINGS
Duct Piece
Length*
Used
Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.
10" round
to 8" round
5 ft.
1 ft.
For best results, use 10" diameter duct.
Round,
straight
(per foot length)
Note: Do not exceed maximum permissable
equivalent lengths!
90° elbow
45° elbow
8" Dia. 52 ft.
10" Dia. 24 ft.
Maximum recommended duct
length for these hoods: 150 feet
8" Dia. 31 ft.
10" Dia. 14 ft.
Flexible ducting:
If flexible metal ducting is used, all
the equivalent feet values in the table
should be doubled. The flexible
metal duct should be straight and
smooth and extended as much as
possible.
Round
wall cap
with damper
8" Dia. 99 ft.
10" Dia. 41 ft.
Round
roof cap
8" Dia. 136 ft.
10" Dia. 56 ft.
Do NOT use flexible plastic ducting.
Note: Any home ventilation system, such as a
ventilation hood, may interrupt the proper flow of
combustion air and exhaust required by fireplaces,
gas furnaces, gas water heaters and other naturally
vented systems. To minimize the chance of interruption
of such naturally vented systems, follow the heating
equipment manufacturer’s guidelines and safety
standards such as those published by NFPA and ASHRAE.
Total Duct Run
Hoods Are Equipped
For 10" Round Duct
*Hoods are supplied with a 10"
round transition. A locally
supplied transition is required
for other sizes.
Note: Outlet on top of hood is
8-1/8" x 8".
*Actual length of straight duct plus duct
fitting equivalent. Equivalent length of duct
pieces are based on actual tests conducted
by GE Evaluation Engineering and reflect
requirements for good venting performance
with any ventilation hood.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
1/4" pivoting
hex socket
Hammer
Duct tape
Electric or battery operated drill
and 1/8", 3/8" bits
Key Hole Saw
Wire cutter/stripper
Pencil and tape measure
Spirit level
10" round metal
duct, length to
suit installation.
Safety glasses
Wire nuts
Phillips and flat
blade
screwdrdivers
Flashlight
Strain relief for
junction cover.
Step ladder
120V 60Hz. 15 or 20 Amp,
Pliers
Metal Snips
Saber saw
or Sawsall
2-wire with ground. Properly
grounded branch circuit.
REMOVE THE PACKAGING
•Remove packages from the “V” shaped cardboard
section. Remove shipping pads.
•Grease filters must be removed. Grasp the latch, pull
the filter up and lift out.
•Lift the hood out of the box.
IMPORTANT:
Lift the hood by grasping
the outside edges of the exhaust opening on the top.
Duct
Transition
Wood
Mounting
Support
Parts
•Lift to remove the grease trays. Set grease filters and
trays aside for later installation. DO NOT DISCARD.
Hood
Motor
Mounted
on Skid
Shipping Carton
• The vent hood motor is shipped secured to the skid with
4 screws. Locate and remove 2 screws on each side of the
motor. Discard the shipping skid and screws.
•From the inside of the hood, loosen (do not remove)
the 2 screws holding the wood mounting support to
the back of the hood. The screws should be backed
out of the wood to 1/4". Remove and set aside the
mounting support with screws for later installation.
DO NOT DISCARD.
•Remove tape and packing material from the hood and
all supplied parts.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Preparation
PARTS PROVIDED
Locate the parts packed with the hood.
Wood Support
with Original Screws
Duct Transition
with Damper
2 Stainless Steel Grease Filters
(3 filters with 48" models)
Heat Lamp
(2 with 48" models)
2 Implement Rods and 4 Stand-offs
Backguard
Allen Wrench
For Implement Rods
Grease Tray
Warming Shelf
HARDWARE
PACKAGE
Locate and check contents.
Screws shown actual size.
Note: Hardware appearance
may vary slightly.
4 Phillips head screws to
secure the duct transition to
the hood outlet on the top.
4 screws to secure the wood
support to the wall
POZIDRIV 3
2 flat washers
for wall anchors
6 (3/16") hollow wall anchors
with screws use 2 to secure
hood to the wall at the bottom.
Use 4 to secure backguard
and shelf.
2 Phillips head machine
screws to secure shelf to
bottom of hood.
10 Phillips head screws.
Use 6 to secure hood to the
wood support. (2 are
secured to wood support)
Use 2 to secure 30" and 36"
backguards to wall. Use 4 to
secure a 48" backguard.
2 shoulder screws
to secure shelf to
bottom of hood.
1 hex head safety screw
and lock washer, to
secure the blower.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
• Use a level to draw the cooktop centerline location.
Draw the line to ceiling height.
• Measure desired distance from the bottom of the hood
9-7/8"
to the cooking surface.
Top of Hood
Note: If you are installing the hood with duct covers, be sure to read
“Using Duct Cover Accessories” page 7. Exact installation height
may be determined by use of one or more duct covers.
Wood
22-1/2"
Support
20"
• Determine bottom
of hood location
(Dimension A) by
subtracting 12-1/2"
from the desired
installation height.
*House Wiring
Location
Bottom of Hood
Dimension A
Installation
Height
Dim. A
Cooking Surface
*See recessed
location below.
FOR VERTICAL (Straight Up) DUCTING:
•Use a level to draw a centerline from the bottom of the
hood to ceiling or soffit.
•If venting out the ceiling, extend the centerline
forward on the ceiling or soffit.
•Use a level to draw a straight horizontal pencil line
indicating the bottom of the hood.
•From the line indicating the bottom of the
hood, measure 20" up and draw another line for
the location of the wood support. See illustration.
•Locate the centerline of a 10-1/2" hole on the ceiling
or soffit by measuring 6" from the wall.
FOR DUCTING THROUGH REAR WALL:
• Measure 9-7/8" above the marked line for the top of
the hood. At the centerline, draw a horizontal line to
mark the location for a 10-1/2" diameter hole.
House Wiring Location:
•The junction box is fastened to the back of the hood
on the right side.
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
6-1/2"
14-1/4"
14" for 48" Models
8" for 36" Models
5" for 30" Models
Electrical
Area
Alternate Knockout Locations (for soffit installation)
If the installation requires, the junction box can be
relocated from the back to the top of the hood. Remove
3 screws, align box to top knockout and secure with
original screws.
•The recessed back side of the hood provides a large
area for the house wiring to exit the wall and be
routed to the rear knockout and junction box.
•The location for the house wiring depends on the
installation height of the hood and the width of the
hood. See shaded “Electrical Area” for locations.
•Remove junction box cover and knockout. Install
strain relief.
•Remove junction box cover and knockout. Install strain
relief.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
STEP 2A INSTALL HOOD ONTO WALL
IMPORTANT: Framing must be capable of
supporting up to 150 lbs.
Install Transition Onto Top of Hood
SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR
CABINET, GO TO STEP 2B.
Duct
Transition
• Locate at least 2 vertical studs at the wood support.
• Center the supplied wood support, left to right and below the
20" marked line.
IMPORTANT: Remove
shipping tape from
damper and check that
damper moves freely.
op of
T
Hood
• Place the duct transition piece over the hood exhaust and secure
Wood
Support
with 4 screws provided.
• Use duct tape to seal the connection. Check to be sure the
damper moves freely.
20"
Bottom
of
Hang Hood On Wood Support
Hood
• Lift the hood and hold close to the installation location. Route
house wiring through the knockout and into the junction box.
• Place the hood over the wood support. Be sure the mounting
screws engage the keyhole slots in the back of the hood. Tighten
the screws.
Centerline of
Installation
Space
WARNING:
Continue to provide additional
support while the hood is mounted with only these 2 screws. These
screws will not support the weight of the hood. The hood could
fall resulting in damage or personal injury.
• Secure the wood support to 2 or more vertical studs, using
at least 2 of the 4 supplied long screws.
IMPORTANT: Screws must penetrate at least 1-1/2" into
AVERTISSEMENT–
Continuez à fournir un
vertical studs. Countersink screws into support.
soutien additionnel pendant le montage de la hotte avec ces deux
vis seulement. Ces deux vis ne soutiendront pas le poids de la
hotte. La hotte peut tomber, occasionnant des blessures
corporelles ou des dommages matériels.
Note: The mounting
screws must remain in
their original shipping
location. These screws
are positioned to engage
the keyhole slots in the
back of the hood.
• Check to be sure the hood is level and centered.
Original Mounting
Screws as Shipped
Bottom
Mounting
Holes
30"
1/4"
Gap
Centerline of
to
Installation
36"
Space
Test Duct Cover Fit
• Place duct cover(s) over the top of the hood to check for
gaps. Adjust the hood up or down if necessary.
• Adjust depth of original mounting screws in wood support
until they protrude 1/4" forward. This 1/4" gap will provide
clearance to hang the hood.
Install Bottom Mounting Screws
• Drill 1/8" pilot holes into the two bottom mounting holes.
Enlarge the holes if they did not enter studs to 3/8". Insert
anchors for wall fasteners into bottom holes. Remove
anchor screws and add flat washers provided. Drive
screws into anchors and tighten.
• Install 4 additional screws through the inside back of the
hood and into the wood support.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
STEP 2B Alternate Mounting Method
INSTALL HOOD TO SOFFIT OR BENEATH CABINETS
SKIP THIS STEP IF USING WALL MOUNTING
METHOD
IMPORTANT: Soffit framing must be capable
of supporting up to 150 lbs.
When necessary, the hood may be installed so that it is
supported by the soffit.
Install Transition Onto Top of Hood
•The soffit should be constructed with 2 x 4’s.
•Determine the installation location on the wall.
•Continue the centerline forward on the bottom of the
cabinet or soffit.
•The opening above the hood should allow for the 10"
round duct and clearance to slide the hood back
against the wall.
Duct
Transition
IMPORTANT: Remove
shipping tape from
damper and check that
damper moves freely.
Requires 10-1/2" Min.
Opening For Ductwork
and Hood Installation
op of
T
ood
H
• Place the transition piece over the hood exhaust and
secure with 4 screws provided.
• Use duct tape to seal the connection. Check to be sure
the damper moves freely.
Mount Hood onto Soffit or Cabinet
Note: If mounting to the underside of a cabinet with a
recessed bottom, install shims to fill the gap.
A
Soffit
A
•The 2 x 4 studs must be located as shown in the chart,
Dim. A. to accept mounting screws.
Engage Top
Keyhole Slots
Add Shims
If Bottom
Is Recessed
1/4" Gap
“A”
“B”
Centerline to Stud
and Keyhole Slots
Hood Width
At the Top
47-15/16"
35-15/16"
29-15/16"
Push Back
to Wall
Back
Wall
ZV48R
ZV36R
ZV30R
23-9/16"
17-9/16"
14-9/16"
Top View
Front of Hood
•Drive mounting screws into the studs until they
protrude 1/4". The 1/4" gap will provide clearance to
engage the keyhole slots in the top of the hood.
•Lift hood to installation position. Locate house wiring
and route through the knockout (from the back or
top of the hood).
•Lift hood onto mounting screws. Slide back against
the rear wall.
•Tighten mounting screws.
A
2"
8-1/8"
7-1/2"
2-9/16"
8"
C
6"
B
Back of Hood
IMPORTANT: For additional support and to
minimize vibration during operation, the hood
must be secured to the back wall. Use wall anchors
to fasten bottom back of hood to the wall.
•Drill 1/8" pilot holes into the studs at the locations
shown in the top view illustration.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
STEP 3 CONNECT DUCTWORK
STEP 5 INSTALL DUCT COVERS
• Install ductwork, making connections in direction of
airflow as illustrated.
Note: For easier handling, remove cardboard insert
after film is peeled off.
• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints with
duct tape for an airtight seal.
Remove protective film from duct covers. If more than
one duct cover is used, secure each piece together with
screws provided.
•Place the duct cover(s) on top of the hood.
•From inside the hood, secure the duct cover to the
top with the small Phillips head screws supplied with
the covers.
• Use duct tape to seal the
flange connection.
Air Flow
Screw
Reach inside the
hood and push
the damper up
to be sure it
Duct Tape
Over Seam
and Screw
moves freely.
STEP 6 INSTALL MOTOR
Duct Tape
Over Transition
Outlet
STEP 4 CONNECT ELECTRICAL
Attachment
Slot
Spring
Clip
Verify that power is turned off at the source.
•From the inside of the hood, slip motor into the
attachment slot on the left.
•Rotate motor upwards until it snaps into the spring
clip on the right.
•Secure the motor to the hood with the machine
screw and lock washer. (Screw is marked with red
or blue paint.)
WARNING:
If house wiring is not
2-wire with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
AVERTISSEMENT –
Si le câblage
•Plug connector into the motor.
de la maison n’est pas du type à deux fils avec un fil de
terre, l’installateur doit fournir un circuit de terre.
Quand les fils de la maison sont en aluminium, il
prendre soin d’utiliser de la pâte antioxidation
approuvée par UL et des connecteurs pour
l’aluminium-cuivre.
Attachment
Screw
Top
A
Remove
B
Insert Power
Conduit Thru
Strain Relief
and Tighten
Junction Box
Cover
White
Ground
Black
Spring
Clip
IMPORTANT: Connector ends
are designed to mate only
one way. Match flat and
round connectors as shown.
C
Use UL Listed
Wire Nuts
• Use wire nuts to connect incoming ground to green,
white to white and black to black.
• Push wires into junction box and replace cover. Be
sure wires are not pinched.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
• Insert the filter into the opening and drop into the
bottom. Raise filter to the top and lock into place.
STEP 7 INSTALL FILTERS
• Drop grease tray into the hood. The rear tabs should
engage the slots in the hood track.
• To remove the filters, grasp the latch, pull the filter
up and lift out.
This hood can be installed with the
warming shelf and backguard together or
with the warming shelf or backguard alone.
STEP 8 INSTALL BACKGUARD AND SHELF
INSTALL BACKGUARD:
•Remove packaging.
•Place backguard against the bottom of the hood to
use as a template. Mark upper screw locations “A”
and “B”
•Remove backguard.
•Drill four 1/8" pilot holes at screw locations “A”
and “B”.
•If drill did not enter studs, enlarge holes to 3/8".
•Insert wall anchors into the enlarged holes. Remove
screws from wall anchors.
•Align and secure backguard to wall using 2 wall
anchor screws or wood screws in locations “A”.
•For 30" and 36" models, install 2 screws through
hole locations “C” at the bottom of the backguard.
For 48" models, install 4 screws.
INSTALL SHELF OVER BACKGUARD:
•Install two shoulder screws into holes “D” in the
bottom of hood flange leaving 1/8" gap.
•Remove shelf packaging and protective film.
•Engage shoulder screws into the keyhole slots in the
top of the shelf. Slide shelf towards the left to lock
into place.
•Install two 3/4" long machine screws through the
bottom of the shelf into the bottom hood flange,
location “E”.
•Install anchor screws through the shelf and into the
wall holes “B”.
•Remove all protective film.
1/8"
Gap
E
D
B
D
A
E
B
A
B
Mounting
B
Holes for
Backguard (A, C)
and Shelf (B)
D
R
A
U
G
K
C
A
B
C
•If installing the backguard alone, without the
shelf, drive screws in all locations shown.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
STEP 9 INSTALL SHELF “ONLY”
STEP 10 INSTALL IMPLEMENT
RODS
•Remove shelf packaging and protective film.
•If installing the shelf alone, without the backguard,
place shelf against the bottom of the hood and mark
screw hole locations “B” on the wall.
•Drill two 1/8" pilot holes.
•If drill did not enter studs, enlarge holes to 3/8".
•Insert wall anchors into enlarged holes. Remove
screws from wall anchors.
•Install two shoulder screws into holes “D” in the
bottom of hood flange leaving 1/8" gap.
•Engage shoulder screws into the keyhole slots in the
top of the shelf. Slide shelf towards the left to lock
into place.
•Install two 3/4" long machine screws through the
bottom of the shelf into the bottom hood flange,
location “E”.
Screw
Stand-offs
Into
Hood
Use Allen
Wrench to
Secure Rod
to Stand-offs
•Use a flat blade screwdriver to install stand-offs into
the bottom of the hood.
•Align implement rod to stand-offs with the screw hole
towards the inside of the hood. Secure the rod to the
stand-offs with the supplied Allen wrench.
1/8"
Gap
•Follow the same procedure on the opposite side.
E
D
B
D
E
FINALIZE INSTALLATION
•Install the supplied infrared bulb(s).
•See the Owner’s Manual for instructions to test
operation.
B
Mounting
Holes
for Shelf (B)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: While performing installations described in this book,
safety glasses or goggles should be worn.
For Monogram® local service in your area, call
1.800.444.1845.
Note: Product improvement is a continuing endeavor at
General Electric. Therefore, materials, appearance and
specifications are subject to change without notice.
GE Consumer & Industrial
GE Appliances
General Electric Company
Louisville, KY 40225
Pub. No. 49-80152-4
11-07 JR
ge.com
Printed in Italy
©2007 GE Company
Download from Www.Somanuals.com. All Manuals Search And Download.
|