OPERATION
BLOWER
MEDIUM
SPEED
Controls
LIGHT
SWITCH
PILOT
LAMP
The hood is operated using the (4) push-buttons located at eye-level, on the front
edge of the hood.
BLOWER
BLOWER
HIGH
SPEED
ON-LOW /
OFF
SWITCH
The light switch turns the halogen lamps on and off.
The blower on-low / off switch turns the blower on to its lowest running speed. The
blower must be turned on using this switch. Turn the blower off by pressing this
switch a second time.
The blower medium speed switch changes the blower speed to medium. This
switch works only if the blower is already running at low or high speed.
The blower high speed switch changes the blower speed to high. This switch works
only if the blower is already running at low or medium speed.
The pilot lamp lights up whenever the blower is on.
FIG. 1
HALOGEN BULBS
This range hood requires two halogen bulbs (Type GU10, MR16 shielded, 120V,
50W).
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT
ANY OPERATIONS ON THE APPLIANCE.
1. Loosen the ring nut by turning it counterclockwise.
2. Loosen the bulb by turning it counterclockwise; pull the bulb downwards to
remove. CAUTION: BULB MAY BE HOT!
3. Replace with Type GU10, MR16 shielded, 120V, 50W halogen bulb.
BULB
RING NUT
FIG. 2
MAINTENANCE
Proper maintenance of the Range Hood will assure proper performance of the unit.
Grease Filters
The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are dishwasher safe.
See “INSTALL FILTERS” section for removal and installation instructions.
Non-Ducted Recirculation Filters
The non-ducted recirculation filters should be changed every 6 months.
See “INSTALL FILTERS” section for removal and installation instructions.
Hood Cleaning
Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance.
Cleaning tips:
● Hot water with soap or detergent is all that is usually needed.
● Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
● For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing
powder with a little water and a soft cloth.
● For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in
direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.
● DO NOT allow deposits to remain for long periods of time.
● DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
● DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel
for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after
exposure and wipe dry with a clean cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Hood
1 - Decorative Flue Assembly
1 - Parts Bag containing:
1 - Mounting Bracket
1 - Discharge Collar
DISCHARGE
COLLAR
MOUNTING
BRACKET
1 - Flue Mounting Bracket
8 - Mounting Screws (4,8 x 38mm Pan Head)
4 - Mounting Screws (3,9 x 9,5mm Pan Head)
2 - Mounting Screws (3.9 x 6mm Flat Head)
8 - Drywall Anchors
1 - Installation Instructions
4 MOUNTING
SCREWS (3.9 x
9.5mm Pan Head)
2 MOUNTING BRACKET
SCREWS
(3.9 x 6mm Flat Head)
8 DRYWALL
ANCHORS
FLUE MOUNTING
BRACKET
8 MOUNTING SCREWS
(4.8 x 38mm Pan Head)
DECORATIVE
FLUE
FIG. 3
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL THE DUCTWORK
(DUCTED HOODS ONLY)
ROOF CAP
6”
!
CAUTION: To reduce the risk of fire, use only metal ductwork.
ROUND DUCT
1. Decide where the ductwork will run between the hood and the outside.
DECORATIVE
WALL
CAP
2. A straight, short duct run will allow the hood to perform most efficiently.
FLUE
HOOD
ROUND
ELBOW
3. Long duct runs, elbows, and transitions will reduce the performance of the
hood. Use as few of them as possible. Larger ducting may be required for best
performance with longer duct runs.
24” TO 30” ABOVE
COOKING SURFACE (see
“INSTALL MOUNTING
BRACKETS” section for
mounting restrictions
6”
ADAPTER
4. Install a roof or wall cap. Connect round metal ductwork to cap and work back
towards hood location. Use duct tape to seal the joints between ductwork sec-
tions.
FIG. 4
INSTALL ELECTRICAL
(DUCTED AND NON-DUCTED HOODS)
WARNING: Electrical wiring must be done by a qualified person(s) in accor-
dance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wir-
ing.
6-1/2”
3-1/4”
1. Plan where the hood will be located above the cook top. Refer to the “INSTALL
MOUNTING BRACKET” section for hood mounting height options.
2. Install a standard 2” x 4” wall outlet box and 3-blade 125 volt, 15 Amp grounded
receptacle.
18” to 22”
3. Mount the 18” to 22” below the bottom of the hood.
4. Locate the receptacle within the boundary shown and off center of the ductwork
(to allow for power cord plug and flue clearance).
FIG. 5
INSTALL MOUNTING BRACKET
(DUCTED AND NON-DUCTED HOODS)
FRAMING BEHIND WOOD CROSS
SUPPORT
1. Construct wood wall framing that is flush with interior surface of wall studs.
Make sure:
a) the framing is centered over installation location.
b) the height of the framing will allow the mounting bracket to be secured to
the framing within the dimensions shown.
2. After wall surface is finished, secure mounting bracket to framing using dimen-
sions shown.
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a)
CEILING HEIGHT
DRYWALL
WOOD
24”
25”
26”
27”
28”
29”
30”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
CROSS
SUPPORT
8-FOOT
37-7/8”
38-7/8”
39-7/8”
39-7/8”
9-FOOT
41-7/8”
41-7/8”
42-7/8”
42-7/8”
43-7/8”
43-7/8”
FIG. 6
40-7/8”
10- FOOT (see note b)
Note a - Minimum hood distance above cook top must not be less than 24”.
A maximum 30” above cook top is highly recommended for best capture of cooking
impurities.
Distances over 30” are at the installers discretion; and if ceiling height and flue length
permit.
Note b - a 10-foot high celing requires use of an optional flue extension, available
from your local dealer.
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL FLUE MOUNTING BRACKET
(DUCTED AND NON-DUCTED HOODS)
1. Assemble the flue mounting bracket, adjusting outside width as shown. See Figure 7.
2. Carefully center the mounting bracket directly over the range hood location.
3. Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors (Fig. 8). Make sure
the bracket is pushed into the corner, tight against the wall and centered over the hood.
FLUE MOUNTING BRACKET
DRYWALL ANCHORS
3.9 x 6 mm
FLAT HEAD
BRACKET SCREWS
7-3/4”
(196.8 mm)
4.8x38mm
MOUNTING SCREWS
FIG. 7
FIG. 8
PREPARE THE HOOD
Note: On stainless steel hoods, carefully remove the plastic protective film
from all exterior surfaces of the hood and decorative flues, prior to final
installation.
DISCHARGE
COLLAR
DUCT
CONNECTOR
(DUCTED HOODS ONLY)
Install the discharge collar into the duct connector of the range hood. Fig. 9.
FIG. 9
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
PREPARE THE HOOD
(NON - DUCTED HOODS ONLY)
Note: The following materials must be purchased separately for non-ducted recirculation installations.
• Non - Ducted Recirculation Kit, Model DFKTWC51EC.
• 5” diameter metal duct.
1. Discard discharge collar and damper supplied with the hood. Install the 5” to 6” adapter supplied with the Non-Ducted
Recirculation Kit. Fig. 10.
2. Secure the plenum to the flue mounting bracket with (2) 3.9x6mm flat head screws (the screws are supplied with the
Non-Ducted Recirculation Kit “DFKTWC51EC”). Fig. 11.
FLUE MOUNTING
5”-6”
ADAPTER
BRACKET
3.9x6mm
FLAT HEAD
SCREWS
PLENUM
FIG.10
FIG.11
INSTALL THE HOOD
(DUCTED AND NON-DUCTED HOODS)
Note: at least two people will be required to mount the hood.
1. Raise the hood into its mounting position.
2. Align the rectangular opening on the back of the hood with the wall-mounting bracket. Gently lower the hood until it
securely engages the bracket. Fig. 12.
3. Level the hood with 2 mounting screws (3.9x9.5mm) and secure with (4) mounting screws. Use drywall anchors provided
if wall studs or framing are not available. Fig. 12.
4. On ductedhoods, attach 6” round metal duct between the hood’s blower collar and duct that leads to the outside location.
5. On non-ducted hoods, attach 5” round metal expandable duct between the 5”-6” adapter on the hood and the connector
on the plenum.
6. Tape all duct joints to make them secure and air tight.
7. Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue.
MOUNTING SCREWS
(4.8x38mm)
WALL FRAMING
MOUNTING SCREWS
(3.9x9.5mm)
MOUNTING SCREWS
MOUNTING
(4.8x38mm)
BRACKET
RECTANGULAR
CUTOUT
FIG.12
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL THE HOOD, cont’d
8. Carefully place the decorative flue on the hood. Fig. 13.
- On ducted installation in rooms with 8-foot ceilings, the air vents are concealed. Install the flue with the air vents
down.
- On non-ducted installations in rooms with 8-foot ceilings, the air vents are exposed. Install the flue with the air vents
up.
- On ducted and non-ducted installations in rooms with 9-foot ceilings, the vents are exposed. Install the flue with air
vents up.
ROOMS WITH 10-FOOT CEILINGS
(DUCTED HOODS ONLY)
Rooms with 10-foot ceilings require flue extension model FXWC51EC available from your local dealer.
9. Discard the upper flue supplied with the product. Replace it with the flue extension.
10. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 14.
12. Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 14.
UPPER FLUE
UPPER FLUE
VENTS EXPOSED
VENTS
3.9x9.5mm
CONCEALED
MOUNTING SCREWS
UPPER
FLUE
LOWER
FLUE
LOWER
FLUE
FIG.14
FIG. 13
INSTALL FILTERS
(DUCTED AND NON-DUCTED HOODS)
1. To remove the GREASE filter, push in on the metal latch tab and tilt filter
downward to remove.
2. To install the GREASE filter, align rear filter tabs with slots in the hood. Depress
the metal latch tab, push filter into position and release. Make sure filter is
securely engaged after installation.
GREASE FILTERS
NOTE: Prior to use, remove protective film from the filter frame.
FIG.15
(NON-DUCTED HOODS ONLY)
1. To remove the NON-DUCTED RECIRCULATION filters, rotate them.
2. To install the NON-DUCTED RECIRCULATION filters, position the filter over
the blower; rotate to lock filters in place (Fig. 16).
3. Install GREASE filters after Non-ducted Recirculation filters are installed.
NON-DUCTED
RECIRCULATION
FILTERS
FIG.16
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS - LISTE PIECES DE RECHANGE
MODELS PL30WC51EC - PL36WC51EC - PL42WC51EC
KEY No.
DESCRIPTION (ENGLISH )
Grease Filter
Motor Capacitor
Connection Box Support
Electrical Box Support
Lamp Bulb
Blower
Motor
Blower Wheel
Rubber Washer
Feeder Cable
Cable
Discharge Collar
Logo
Decorative Flue Bottom
Decorative Flue Top
Flue Mounting Bracket
Feeder Cable Connection Box
Feeder Cable Connection Box Cover
Junction Clamp
N.
DESCRIPTION (FRANCAIS)
9
14
9
Filtre à graisse
Condensateur
14
16
16
Support boîte cable alimentation
Support boîte installation electrique
Ampoule
16
16
26
26
45
45
Convoyer
48
48
Moteur
49
49
Turbine
53
53
Pare chocs
60
60
Cable alimentation
Cable
67
67
86
86
Bride de raccordement
Plaquette logo
113
118
119
120
145
146
147
151
152
165
195
223
228
229
230
234
240
250
407
477
998
ALA
113
118
119
120
145
146
147
151
152
165
195
223
228
229
230
234
240
250
407
477
998
ALA
Conduit décoratif inférieur
Conduit décoratif supérieur
Etrier de support
Boîte cable alimentation
Couvercle boîte cable alimentation
Borne
Serre cable
Serre cable
Boîte installation electrique
Support
Bouton
Circuite commandes
Voyant lumineux
Couvercle commandes
Boîte commandes
Sous-bouton
Bague
Etrier support convoyer
Fermeture
Electrical Box Wires Stop
Feeder Cable Clamp
Electrical Box Capacitor
Bracket
Switch Button
Controls Board
Warning lamp
Switch board box cover
Switch board box
Switch Actuator
Ring Nut
Blower Support Bracket
Closing
Hardware Package
Halogen Support Assembly
Accessoires de fixation
Ensemble support lampe halogène
- 18 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS - LISTE PIECES DE RECHANGE
MODELS PL30WC51EC - PL36WC51EC - PL42WC51EC
- 19 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|