FortiAnalyzer-4000B®
Rack and Hardware Install Guide
Version 4.0 MR2
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Identifying the Inner Rack Rails . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installing the Inner Rails on the Chassis . . . . . . . . . . . . . . . . . . . . . . 10
Installing the Outer Rails onto a Rack . . . . . . . . . . . . . . . . . . . . . . . 11
Installing the Chassis into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . 12
Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Welcome and thank you for selecting Fortinet products for your network protection.
Fortinet® ASIC-accelerated multi-threat security systems improve network security, reduce
network misuse and abuse, and help you use communications resources more efficiently
without compromising the performance of your network. Fortinet systems are ICSA-
certified for Antivirus, Firewall, IPSec, SSL-TLS, IPS, Intrusion detection, and AntiSpyware
services.
Fortinet systems are dedicated, easily managed security devices that deliver a full suite of
capabilities including:
•
•
•
Application-level services such as virus protection, intrusion protection, spam filtering,
web content filtering, IM, P2P, and VoIP filtering
Network-level services such as firewall, intrusion detection, IPSec and SSL VPN, and
traffic shaping
Management services such as user authentication, logging, reporting with
FortiAnalyzer, administration profiles, secure web and CLI administrative access, and
SNMP.
The Fortinet security system uses Fortinet’s Dynamic Threat Prevention System
(DTPS™) technology, which leverages breakthroughs in chip design, networking, security
and content analysis. The unique ASIC-accelerated architecture analyzes content and
behavior in real-time, enabling key applications to be deployed right at the network edge
where they are most effective at protecting your networks.
This chapter contains the following topics:
•
•
•
•
Registering your Fortinet product
Before you begin, take a moment to register your Fortinet product at the Fortinet Technical
Many Fortinet customer services, such as firmware updates, technical support, and
FortiGuard Antivirus and other FortiGuard services, require product registration.
For more information, see the Fortinet Knowledge Center article Registration Frequently
Customer service and technical support
Fortinet Technical Support provides services designed to make sure that your Fortinet
products install quickly, configure easily, and operate reliably in your network.
To learn about the technical support services that Fortinet provides, visit the Fortinet
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Fortinet documentation
Introduction
You can dramatically improve the time that it takes to resolve your technical support ticket
by providing your configuration file, a network diagram, and other specific information. For
a list of required information, see the Fortinet Knowledge Center article What does
Fortinet documentation
most up-to-date versions of Fortinet publications, as well as additional technical
documentation such as technical notes.
In addition to the Fortinet Technical Documentation web site, you can find Fortinet
technical documentation on the Fortinet Tools and Documentation CD, and on the Fortinet
Knowledge Center.
Fortinet Tools and Documentation CD
Many Fortinet publications are available on the Fortinet Tools and Documentation CD
shipped with your Fortinet product. The documents on this CD are current at shipping
time. For current versions of Fortinet documentation, visit the Fortinet Technical
Fortinet Knowledge Center
The Fortinet Knowledge Center provides additional Fortinet technical documentation,
such as troubleshooting and how-to-articles, examples, FAQs, technical notes, a glossary,
Comments on Fortinet technical documentation
Please send information about any errors or omissions in this or any Fortinet technical
Conventions
Fortinet technical documentation uses the conventions described below.
IP addresses
To avoid publication of public IP addresses that belong to Fortinet or any other
organization, the IP addresses used in Fortinet technical documentation are fictional and
follow the documentation guidelines specific to Fortinet. The addresses used are from the
private IP address ranges defined in RFC 1918: Address Allocation for Private Internets,
CLI constraints
CLI constraints, such as <address_ipv4>, indicate which data types or string patterns
are acceptable input for a given parameter or variable value. CLI constraint conventions
are described in the CLI Reference document for each product.
Notes, Tips and Cautions
Fortinet technical documentation uses the following guidance and styles for notes, tips
and cautions.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Conventions
Tip: Highlights useful additional information, often tailored to your workplace activity.
Note: Also presents useful information, but usually focused on an alternative, optional
method, such as a shortcut, to perform a step.
Caution: Warns you about commands or procedures that could have unexpected or
undesirable results including loss of data or damage to equipment.
Typographical conventions
Fortinet documentation uses the following typographical conventions:
Table 1: Typographical conventions in Fortinet technical documentation
Convention
Example
Button, menu, text box, From Minimum log level, select Notification.
field, or check box label
CLI input
config system dns
set primary <address_ipv4>
end
CLI output
FGT-602803030703 # get system settings
comments
opmode
: (null)
: nat
Emphasis
HTTP connections are not secure and can be intercepted by
a third party.
File content
<HTML><HEAD><TITLE>Firewall
Authentication</TITLE></HEAD>
<BODY><H4>You must authenticate to use this
service.</H4>
Hyperlink
Keyboard entry
Type a name for the remote VPN peer or client, such as
Central_Office_1.
Navigation
Publication
Go to VPN > IPSEC > Auto Key (IKE).
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Conventions
Introduction
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack and Hard Drive Installation
Instructions
The FortiAnalyzer-4000B comes with a sliding rail kit. Use the instructions below to install
the rails.
Caution: Only trained service technicians are authorized to remove the system cover and
access any of the components inside the system. Before you begin, review the safety
instructions that came with the system.
Installing Hard Drives
Removing Hard Drive Trays from the Chassis
To remove a hard drive tray from the chassis
1 Press the release button on the drive tray. This extends the drive bay handle.
2 Use the handle to pull the drive out of the chassis.
Figure 1: Removing the hard drive.
2
1
The drives are mounted in drive trays to simplify their installation and removal from the
chassis. These trays also help promote proper airflow for the drive bays.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Hard Drives
Rack and Hard Drive Installation Instructions
Figure 2: Chassis drive tray.
Dummy drive
Drive tray
Note: Except for short periods of time (swapping hard drives), do not operate the server
with the hard drives empty.
Installing a Hard Drive to the Hard Drive Tray
To install a hard drive into the hard drive tray
1 Remove the two screws securing the dummy drive to the drive tray and remove the
dummy drive. Place the hard drive tray on a flat surface such as a desk, table or work
bench.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack and Hard Drive Installation Instructions
Installing Hard Drives
Figure 3: Removing dummy drive from tray.
2 Slide the hard drive into the tray with the printed circuit board side facing down.
Figure 4: Installing the hard drive into the tray.
SATA hard
drive
Drive tray
3 Carefully align the mounting holes in both the drive tray and the hard drive.
4 Secure the hard drive to the tray using six screws.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack Installation
Rack and Hard Drive Installation Instructions
5 Replace the drive tray into the chassis. Make sure to close the drive tray handle to lock
the drive tray into place.
Figure 5: Installing the hard drive in the chassis.
Rack Installation
Overview
This chapter provides a quick setup checklist to get your chassis up and running.
Following these steps in the order given should enable you to have the system operational
within a minimum amount of time.
Unpacking the System
You should inspect the box the chassis was shipped in and note if it was damaged in any
way. If the chassis itself shows damage you should file a damage claim with the carrier
who delivered it.
Decide on a suitable location for the rack unit that will hold your chassis. It should be
situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical
noise and electromagnetic fields are generated. You will also need it placed near a
grounded power outlet. Be sure to read the Rack and Server Precautions in the next
section.
Preparing for Setup
The box your chassis was shipped in should include two sets of rail assemblies, two rail
mounting brackets and the mounting screws you will need to install the system into the
rack. Read this section in its entirety before you begin the installation procedure outlined in
the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches).
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack and Hard Drive Installation Instructions
Rack Installation
Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient
airflow and ease in servicing.
Warnings and Precautions!
This product is for installation only in a Restricted Access Location (dedicated equipment
rooms, service closets and the like).
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with
the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack.
In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the rack.
You should extend only one component at a time - extending two or more simultaneously
may cause the rack to become unstable.
General Server Precautions
Review the electrical and general safety precautions that came with the components you
are adding to your chassis.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components on the bottom of the rack first, and then work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from power
surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug hard drives and power supply modules to cool before touching them.
Always keep the rack's front door and all panels and components on the servers closed
when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of
the rack environment may be greater than the ambient temperature of the room.
Therefore, consideration should be given to installing the equipment in an environment
compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe
operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise
due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply
circuitry and the effect that any possible overloading of circuits might have on overcurrent
protection and power supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack Mounting Instructions
Rack and Hard Drive Installation Instructions
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be
grounded. Particular attention should be given to power supply connections other than the
direct connections to the branch circuit (i.e. the use of power strips, etc.).
Rack Mounting Instructions
Rack Rails Assembly
This section provides information on installing the SC846 chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean that the
assembly procedure will differ slightly. You should also refer to the installation instructions
that came with the rack unit you are using.
Note: This rail will fit a rack between 27" and 34.45" deep.
Caution: The left and right rails differ from each other. Do not exchange their inner rails.
Caution: Keep the ball bearing shuttle locked at the front of the middle rail during
installation.
Caution: A minimum of two people are required for safe installation of the chassis.
To install the unit on the rack
1 Pull the inner rail out of the outer rail until it is fully extended.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack and Hard Drive Installation Instructions
Rack Mounting Instructions
Figure 6: Pulling the inner rail out of the outer rail until it is fully extended and pressing
the locking tab down.
PULL
Figure 7: Releasing the inner rail.
Outer rail
Middle rail
Inner rail
3 Place the inner rail firmly against the side of the chassis. Make sure that the hooks
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack Mounting Instructions
Rack and Hard Drive Installation Instructions
Figure 8: Attaching the rails to the chassis.
1
3
Screw
1
3
Screw
Slide the inner rail
6 Press the locking tab and push the middle rail back into the outer rail.
Figure 9: Press the locking tab and push the middle rail back into the outer rail.
7 Hang the hooks of the rails on the rack holes and if necessary, secure with screws.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack and Hard Drive Installation Instructions
Rack Mounting Instructions
Figure 10: Inserting the hooks on the rails.
Optional
screws
8 Repeat Step 7 to mount the four ends, extending the rails as necessary.
Figure 11: Installing the rails to the server rack.
9 Pull the middle rail out of the front of the outer rail and make sure that the ball bearing
shuttle is locked at the front of the middle rail.
10 Align the inner rails with the middle rails and then push evenly on both sides of the
chassis until it clicks into the fully extended position.
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack Mounting Instructions
Rack and Hard Drive Installation Instructions
Figure 12: Installing the chassis on the rack.
Ball bearing
shuttle
11 Depress the locking tabs on both sides of the chassis simultaneously and push the
chassis all the way into the rear of the rack.
12 If additional security is required, secure the chassis handles to the front of the rack with
two screws (optional).
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack and Hard Drive Installation Instructions
Rack Mounting Instructions
Figure 13: Optional screws to secure chassis to rack.
Screw
Screw
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack Mounting Instructions
Rack and Hard Drive Installation Instructions
FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide
05-420-126194-20100608
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|