®
16
Multimeter with Temperature
Instruction Sheet
P
Read First: Safety Information
To ensure that the meter is used safely, follow these instructions:
•
•
Do not use the meter if the meter or test leads appear damaged, or if
you suspect that the meter is not operating properly.
Disconnect the live test lead before disconnecting the common test
lead.
•
•
When using the probes, keep your fingers behind the finger guards on
the probes.
Do not use the V•Check mode to measure voltages in circuits that
could be damaged by this mode’s low input impedance
( 2 kΩ).
•
•
•
Turn off power to the circuit under test before cutting, desoldering, or
breaking the circuit. Small amounts of current can be dangerous.
Do not apply more than 600V rms between a meter terminal and earth
ground.
Use caution when working with voltages above 60V dc or 30V ac rms.
Such voltages pose a shock hazard.
PN 643657 June 1997 Rev.2, 3/98
1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
AC and DC Voltage
Also refer to V•Check.
Volts AC
Input Impedance 5 MΩ
50 Hz to 400 Hz
Volts DC
Input Impedance 10 MΩ
MULTIMETER
MULTIMETER
16
16
AC
DC
4000 mV 4V 40V 400V 600V
OFF
OFF
V
AC DC
V
AC
/
DC
/
CAT
CAT
600V
600V
COM
+
COM
+
ip01i.eps
Resistance and Continuity eR
Turn off circuit power before testing. Also refer to V•Check.
Resistance
Continuity
16
MULTIMETER
MULTIMETER
MULTIMETER
16
16
Mk
OFF
OFF
OFF
V
•Check
V
•Check
V•Check
A
Low Impedance
V•Check
A
A
CAT
CAT
CAT
TEMPERATURE
TEMPERATURE
TEMPERATURE
600V
600V
600V
COM
+
COM
+
COM
+
400Ω 4 kΩ 40 kΩ 400 kΩ 4 mΩ 40 mΩ
Short
Open
<25Ω
ip02i.eps
Detects shorts and opens ≥250 µS.
Download from Www.Somanuals.com. All Manuals Search And Download.
W V•Check
If a dc or ac voltage greater than about 4.5V is present across the inputs
when the meter is set to R, G, or e, the meter switches automatically
to dc or ac voltage mode (V•Check mode).
W Warning
Repetitive transients on a dc bus will cause V•Check to
select ac volts, even though a hazardous dc voltage may
be present. To avoid a misleading display and possible
electric shock, manually select the proper volts function
for measurements on these circuits.
When V•Check is activated, the meter has low input impedance (LoZ)
2 kΩ. This load can alter the voltages in electronic control circuits. Do
not use V•Check to measure voltage in circuits that could be damaged by
a 2 kΩ load.
Hint: V•Check can be effectively used to eliminate “ghost” voltages.
Disable and re-enable V•Check
For and Ω,
If AC detected
If DC detected
MULTIMETER
16
,
Disables V•Check and
locks meter in selected
mode.
Meter puts 2 kΩ
load on circuit.
2 sec
OFF
V
•Check
A
CAT
TEMPERATURE
600V
or
or
COM
+
Re-enables
V•Check
or
ip09i.eps
Download from Www.Somanuals.com. All Manuals Search And Download.
Temperature
MULTIMETER
16
°F
°C
OFF
V•Check
A
CAT
TEMPERATURE
600V
COM
+
Vent
or
Pipe
80PK-1 Type K
Thermocouple
Probe
ip19f.eps
Note correct connector polarity.
To meet stated accuracy, the 80AK temperature adapter must be at the
same temperature as the meter. In addition, the 80AK and the 80PK-1
should be cleaned and lubricated regularly. Use any petroleum based
lubricant.
Warning
To avoid possible electric shock, DO NOT apply
thermocouple tip to any conductor that is greater than
30V AC, 42.4V pk, or 60V DC to earth.
Download from Www.Somanuals.com. All Manuals Search And Download.
Capacitance E
Turn off circuit power; then disconnect and discharge the capacitor before
measuring capacitance.
MULTIMETER
16
If the capacitor requires more
discharging, diSC is displayed
while the capacitor discharges.
OFF
V
•Check
A
CAT
TEMPERATURE
600V
COM
+
1 µF 10 µF
100 µF
10,000 µF
+
ip05i.eps
Note correct probe polarity for polarized capacitors.
Download from Www.Somanuals.com. All Manuals Search And Download.
Microamps µA
Range 0 to 200 µA
MULTIMETER
16
µA AC
µA DC
OFF
V
•Check
A
CAT
TEMPERATURE
600V
COM
+
Flame
sensor
probe
Control
module
ip20i.eps
Example: Flame rectification circuit.
Download from Www.Somanuals.com. All Manuals Search And Download.
Diode Test G
Turn off circuit power before testing. For best results diodes
should be measured out of circuit.
Also refer to V•Check.
Good Diode
MULTIMETER
Typical voltage
for silicon diode
MULTIMETER
16
16
Low Impedance
V•Check
OFF
OFF
V
•Check
V•Check
A
A
CAT
CAT
TEMPERATURE
TEMPERATURE
600V
600V
COM
+
COM
+
Single beep
ip03i.eps
Forward Bias
Reverse Bias
Bad Diode
MULTIMETER
16
MULTIMETER
16
OFF
OFF
V•Check
V•Check
A
A
CAT
TEMPERATURE
CAT
TEMPERATURE
600V
600V
COM
+
COM
+
or
ip04i.eps
Shorted
Open
Download from Www.Somanuals.com. All Manuals Search And Download.
µF
MIN MAX
(Records the lowest and highest measurements)
V•Check, autoranging, and Battery Saver are disabled. Put the meter
in the proper range before entering MIN MAX.
When the reading changes more than about 50 digits, the meter gives a
short beep. When a new minimum or maximum is recorded, the meter
gives a long beep.
Enter
MIN MAX
Present Reading with
Input Change AlertTM
Maximum Reading
2 sec
To Exit
Minimum Reading
ip10i.eps
Download from Www.Somanuals.com. All Manuals Search And Download.
µF
MIN MAX with Elapsed Time
Records the hours and minutes between when MIN MAX was entered
and the last high and low was recorded. OL is displayed for times longer
than 99:59.
To enable the MIN MAX timer, hold down M while turning the rotary
switch from OFF to either measurement mode.
Enter MIN MAX. View Maximum Reading
Present Reading
Maximum Reading
Elapsed Time
2 sec
Minimum Reading
Elapsed Time
Minimum Reading
Exit MIN MAX
ip11i.eps
Download from Www.Somanuals.com. All Manuals Search And Download.
Disabling the Beeper
To disable the beeper for all modes, hold down r for 2 seconds while
turning the meter on.
Continuity Capture
To set up the meter to capture intermittent shorts and opens, turn the
switch to GR, connect the leads to the circuit; then press M.
ip12i.eps
Captures transitions longer than 250 µs (1/4000th of a second).
Transitions after the first transition cause the meter to beep, but the
display does not change.
To reset the display to the current condition, press M.
To exit, press M for 2 seconds, or change the measurement mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Clean the case with a damp cloth and detergent. Do not use abrasives or
solvents.
Battery Replacement
Remove the test leads before disassembling the case.
COM
600V
+
+
ip13i.eps
Replacement Parts
Fluke TL-75 (Double-insulated leads)
80AK-8001 (Adapter, Thermocouple)
80PK-1 (Probe, Thermocouple, Beaded K-Type)
PN 855705
PN 919683
PN 750422
Service and Parts
This meter should be serviced only by a qualified service technician. For
service information in the USA and Canada call 1-800-526-4731. To
locate an authorized service center, visit us on the World Wide Web:
below.
USA and Canada: 1-800-44-FLUKE (1-800-443-5853)
Europe: +31 402-678-200
Japan: +81-3-3434-0181
Singapore: +65- -276-6196
*
Anywhere in the world: +1-425-356-5500
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Accuracy is specified for a period of one year after calibration, at 18°C to
28°C (64°F to 82°F) with relative humidity to 90%. AC conversions are
ac-coupled, average responding, and calibrated to the rms value of a sine
wave input. Accuracy specifications are given as follows:
±([% of reading] + [number of least significant digits])
Function
Range
Resolution
Accuracy
-10°C to 400°C
14°F to 752°F
0.1°C or
0.2°F
±(1.0% + 0.8°C)
typical
Temperature
±(1.0% + 1.5°F) typical
±(5.0% + 1.5°C)
typical
(Type K Thermocouple) -40°C to -10°C
-40°F to 14°F
0.1°C or
0.2°F
±(5.0% + 3.3°F) typical
Error does not include Type K Thermocouple errors.
Function
Range
Resolution
Accuracy
4000 mV1
4.000V
1 mV
±(1.9% + 3)
±(1.9% + 3)
±(1.9% + 3)
±(1.9% + 3)
±(1.9% + 3)
0.001V
00.01V
000.1V
1V
40.00V
400.0V
(50 to 400 Hz)
600V
4000 mV1
4.000V
1 mV
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 1)
±(0.9% + 1)
0.001V
00.01V
000.1V
1V
40.00V
400.0V
600V
±(0.9% + 1)
400.0Ω
0.1Ω
±(0.9% + 2)
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
1.000 µF
10.00 µF
100.0 µF
10000 µF
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.001 µF
0.01 µF
0.1 µF
1 µF
±(0.9% + 1)
±(0.9% + 1)
±(0.9% + 1)
±(0.9% + 1)
Ω
±(1.5% + 3)
±(1.9% + 2)
±(1.9% + 2)
±(1.9% + 2)
≤1000 µF ±(1.9% + 2)
>1000 µF ±(10% + 90) typical
±(1.9% + 2)2
2.000V
0.001V
1.The 4000 mV range can be entered only in manual range mode. Use the
4000 mV range with accessories.
2.The beeper is guaranteed to come on at <25Ω and turn off at >250Ω. The
meter detects opens or shorts ≥250 µs.
Download from Www.Somanuals.com. All Manuals Search And Download.
Function
Range Resolution
Accuracy
Burden Voltage
0 to 200 µA
0.1 µA
±(2% + 3 counts)
<5 mV/µA
(50 Hz to 400
Hz)
0 to 200 µA
0.1 µA
±(1% + 2 counts)
<5 mV/µA
Overload
Function
Input Impedance (Nominal)
Protection1
>5 MΩ <100 pF
600V rms
V•Check and LoZ = >2 kΩ <200 pF (ac coupled)2
>10MΩ <100 pF
600V rms
V•Check and LoZ = >2 kΩ <200 pF2
Common Mode Rejection
Normal Mode Rejection
Ratio (1 kΩ Unbalanced)
600V rms >60 dB at dc 50 or 60 Hz
600V rms >100 dB at dc, 50 or 60 Hz >50 dB at 50 Hz or 60 Hz
Full Scale Voltage
Open Circuit Test Voltage
To 4.0 MΩ
40 MΩ
600V rms
600V rms
<1.5V dc
<450 mV dc <1.5V dc
2.400V dc
2.4-3.0V dc
Short Circuit Current
600V rms
600V rms
<500 µA
0.95 mA (typical)
1. 3 x 106 V Hz maximum
2. 2 kΩ input impedance up to 50V. Impedance increases with input voltage to
>300 kΩ at 600V.
MIN MAX Recording Accuracy and Response Time
Specified accuracy of the measurement function ±12 digits in dc for changes
>200 ms in duration (±40 digits in ac). Typical 100 ms response to 80%.
Example 1: This would mean ±1.2° when recording temperature.
Example 2: This would mean ±12 µA when recording µA or ±12A if used with a
dc amp probe (with a mV input).
Download from Www.Somanuals.com. All Manuals Search And Download.
MIN MAX Recording with Elapsed Time
Elapsed Time
Resolution
Accuracy
0 to 100 hours (99:59)
1 minute
0.3% typical
Maximum Voltage
Between any Terminal
and Earth Ground:
600V rms
Display:
3 3/4-digits, 4000 counts, updates 4/sec
Operating Temperature: -10°C to 50°C (14°F to 122°F)
Storage Temperature:
-30°C to 60°C (-22°F to 140°F)
indefinitely (to -40°C (-40°F) for 100 hrs)
Temperature
Coefficient:
(.1 x specified accuracy)/°C (<18°C or
>28°C)
Relative Humidity:
0% to 90% (-10°C to 35°C; 14°F to 95°F)
0% to 70% (35°C to 50°C; 95°F to 122°F)
9V, NEDA 1604 or IEC 6F22
650 continuous hours with alkaline
450 continuous hours with carbon-zinc
3 meter drops.
Battery Type:
Battery Life:
Shock, Vibration:
Size (H x W x L):
3.46 cm x 7.05 cm x 14.23 cm
(1.35 in x 2.75 in x 5.55 in)
Weight:
Safety:
286g (10 oz)
Designed to Protection Class II
requirement of UL1244, ANSI/ISA-S82,
CSA C22.2 No 231, and VDE 0411, and
IEC 1010 overvoltage Category III (CAT
III, 600 Volts).
EMI Regulations:
Certifications:
Complies with FCC Part 15, Class B, and
VDE 0871B. Trademark of TÜV Product
Services. Complies with EN 61010-1:
1993.
TUV, UL and VDE pending
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY & LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under
normal use and service. The warranty period is three years and begins on the date of shipment.
Parts, product repairs and services are warranted for 90 days. This warranty extends only to the
original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses,
disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered,
neglected or damaged by accident or abnormal conditions of operation or handling. Fluke
warrants that software will operate substantially in accordance with its functional specifications for
90 days and that it has been properly recorded on non-defective media. Fluke does not warrant
that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user
customers only but have no authority to extend a greater or different warranty on behalf of Fluke.
Warranty support is available if product is purchased through a Fluke authorized sales outlet or
Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for
importation costs of repair/replacement parts when product purchased in one country is submitted
for repair in another country.
Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of
charge repair, or replacement of a defective product which is returned to a Fluke authorized
service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center or send the
product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to
the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit.
Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB
Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or
abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and
obtain authorization before commencing the work. Following repair, the product will be returned to
the Buyer transportation prepaid and the Buyer will be billed for the repair and return
transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER
ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR
ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or
exclusion or limitation of incidental or consequential damages, the limitations and exclusions of
this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or
unenforceable by a court of competent jurisdiction, such holding will not affect the validity or
enforceability of any other provision.
Fluke Corporation
P.O. Box 9090
Everett WA
Fluke Europe B.V.
P.O. Box 1186
5602 B.D. Eindhoven
The Netherlands
98206-9090
5/94
Download from Www.Somanuals.com. All Manuals Search And Download.
|