Five Star Ranges Ventilation Hood FSH301 BL User Manual

®
Range Hood  
Use & Care / Installation Manual  
FSH481-WH (48” wide - White)  
FSH481-SS (48” wide - Stainless)  
FSH481-BL (48” wide - Black)  
FSH601-WH (60” wide - White)  
FSH601-SS (60” wide - Stainless)  
FSH601-BL (60” wide - Black)  
Models  
FSH301-WH (30” wide - White)  
FSH301-SS (30” wide - Stainless)  
FSH301-BL (30” wide - Black)  
FSH361-WH (36” wide - White)  
FSH361-SS (36” wide - Stainless)  
FSH361-BL (36” wide - Black)  
HB0026  
!
INTENDED FOR DOMESTIC COOKING ONLY  
!
V05650 rev.D  
FIVESTAR, Cleveland, TN 37320-2490  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INSTRUCTIONS  
WARNING  
WARNING  
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE  
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE  
FOLLOWING:*  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR  
INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
1. Use this unit only in the manner intended by the manufacturer.  
If you have questions, contact the manufacturer at the  
address listed in the warranty.  
2. Before servicing or cleaning unit, switch power off at service  
panel and lock the service disconnecting means to prevent  
power from being switched on accidentally. When the  
service disconnecting means cannot be locked, securely  
fasten a prominent warning device, such as a tag, to the  
service panel.  
3. Installation work and electrical wiring must be done by a  
qualified person(s) in accordance with all applicable codes  
and standards, including fire-rated codes and standards.  
4. Sufficient air is needed for proper combustion and  
exhausting of gases through the flue (chimney) of fuel  
burning equipment to prevent backdrafting. Follow the  
heating equipment manufacturer’s guideline and safety  
standards such as those published by the National Fire  
Protection Association (NFPA), and the American Society  
for Heating, Refrigeration and Air Conditioning Engineers  
(ASHRAE), and the local code authorities.  
5. When cutting or drilling into wall or ceiling, do not damage  
electrical wiring and other hidden utilities.  
6. Do not use this range hood with any additional solid state  
speed control device.  
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,  
or metal tray, then turn off the burner. BE CAREFUL TO  
PREVENT BURNS. If the flames do not go out immediately,  
EVACUATEAND CALL THE FIRE DEPARTMENT.  
2. NEVER PICK UPA FLAMING PAN - You may be burned.  
3. DO NOT USE WATER, including wet dishcloths or towels  
- This could cause a violent steam explosion.  
4. Use an extinguisher ONLY if:  
A. You know you have a Class ABC extinguisher and you  
already know how to operate it.  
B. The fire is small and contained in the area where it started.  
C. The fire department is being called.  
D. You can fight the fire with your back to an exit.  
Based on “Kitchen Firesafety Tips” published by NFPA.  
*
!
CAUTION  
1. For general ventilating use only. Do not use to exhaust  
hazardous or explosive materials and vapors.  
2. To avoid motor bearing damage and noisy and/or  
unbalanced impellers, keep drywall spray, construction  
dust, etc. off power unit.  
3. Your hood motor has a thermal overload which will  
automatically shut off the motor if it becomes overheated.  
The motor will restart when it cools down. If the motor  
continues to shut off and restart, have the hood serviced.  
4. For best capture of cooking impurities, the bottom of the  
hood should be a minimum of 24” and a maximum of 30”  
above the cooking surface.  
5. To reduce the risk of fire and to properly exhaust air on a  
ducted installation, be sure to duct air outside - Do not  
exhaust air into spaces within walls or ceiling or into attics,  
crawl spaces, or garage.  
6. This product is equipped with a thermostat which may  
start blower automatically. To reduce the risk of injury and  
to prevent power from being switch on accidentally, switch  
power off at service panel and lock or tag service panel.  
7. To reduce the risk of fire and electric shock, the FIVESTAR  
hood must be installed with FIVESTAR blower models  
FBK600, FBK1200 or exterior blower model 332H only.  
Other blowers cannot be substituted. (Blowers sold  
separately).  
7. Ducted fans must always be vented to the outdoors.  
8. To reduce the risk of fire, use only steel ductwork.  
9. This unit must be grounded.  
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:  
1. Never leave surface units unattended at high settings.  
Boilovers cause smoking and greasy spillovers that may  
ignite. Heat oils slowly on low or medium settings.  
2. Always turn hood ON when cooking at high heat or when  
cooking flaming foods.  
3. Clean ventilating fans frequently. Grease should not be  
allowed to accumulate on fan or filter.  
4. Use proper pan size. Always use cookware appropriate  
for the size of the surface element.  
8. Use with approved cord-connection kit only.  
9. Please read specification label on product for further  
information and requirements.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
CLEANING  
Always turn ON your hood before you begin cooking in order  
to establish an air flow in the kitchen. Let the blower run for a  
few minutes to clear the air after you turn off the range. This  
will help keep the whole kitchen cleaner and brighter.  
Grease filters  
The grease filters should be cleaned frequently. Use a warm  
detergent solution. Grease filters are dishwasher safe.  
Wash more often if your cooking style generates greater  
grease - like frying foods or wok cooking.  
4
6
Remove filters by pushing filters towards the back of hood  
and rotating filters downward.  
5
3
2
Blower Cleaning  
3
3
1
1
Remove the grease filters in order to access the blower.  
Vacuum blower to clean. Do not immerse in water. Refer to  
blower instruction manual for more details.  
HC0004  
1. Warming lamps  
2. Warming lamp switches  
3. Halogen lights  
4. Halogen light switches  
5. ON/OFF Blower switch  
6. Blower speed control  
Grease Rail  
The grease rail should be cleaned frequently, especially if  
baffle filters are used. Remove filters, then, disassemble the  
grease rail from the hood by removing its 3 retaining screws.  
See illustration below.  
Warming Lamps (Infrared)  
Each warming lamp (item 1 on picture above) is controlled  
with is own ON/OFF switch (item 2 on picture above).  
Use only BR40 Size, 250W Max., Infrared bulbs. (Purchase  
separately.)  
WARNING: Do not place highly flammable  
material on warming shelves.  
Cooktop Lighting (Halogen)  
A double set of ON/OFF switches (item 4 on picture above)  
control the halogen lights (item 3 on picture above).  
The front rocker controls the center light. The rear rocker  
controls both side lights. Select one, two, or three lights for  
best cooktop lighting.  
HD0069  
Refer to Stainless steel cleaning in Hood Cleaning section  
below. Once the grease rail is clean and dry, reassemble it to  
the hood and reinstall filters.  
Use PAR 20, 50W halogen bulbs. (Purchase separately.)  
Blower  
Hood Cleaning  
The blower is operated using two (2) controls.  
Stainless steel cleaning: How to maintain its ‘’BRIGHT LOOK’’  
Use the ON/OFF blower switch (item 5 on picture above) to  
start and stop the blower. When turned on, the blower will  
operate at the previous setting of the speed control (item 6 on  
the picture above).  
Turn the speed control knob clockwise to decrease blower  
speed - counterclockwise to increase speed.  
Do:  
- Regularly wash surfaces with clean cloth or rag soaked  
with warm water and mild soap or liquid dish detergent.  
- Always clean in the diredtion of original polish lines.  
- Always rinse well with clear water (2 or 3 times) after cleaning.  
Wipe dry completely.  
HEAT SENTRYTM  
Your hood is equipped with a HEAT SENTRYTM thermostat.  
This thermostat is a device that will turn on or speed up the  
blower if it senses excessive heat above the cooking surface.  
- You may also use a specialized household stainless steel  
cleaner.  
Don’t:  
- Do not use any steel or stainless steel wool or any other  
scrapers to remove stubborn dirt.  
1) If blower is OFF - it turns blower ON to high speed.  
2) If blower is ON at a lower speed setting - it turns blower up  
to HIGH speed.  
When the temperature level drops to normal, the blower will  
return to its original setting.  
- Do not use any harsh or abrasive cleaners.  
- Do not allow dirt to accumulate.  
- Do not let plaster dust or any other construction residues  
reach the hood. During construction/renovation, cover the  
hood to make sure no dust sticks to stainless steel surface.  
WARNING: The HEAT SENTRYTM thermostat can  
start the blower even if the hood is turned OFF.  
When this occurs, it is impossible to turn the  
blower OFF with the switch. If you must stop  
the blower, do it from the main electrical panel.  
Avoid: when choosing a detergent  
- Any cleaners that contains bleach will attack stainless steel.  
- Any products containing: chloride, fluoride, iodide,  
bromide will deteriorate surfaces rapidly.  
- Any combustible products used for cleaning such as  
acetone, alcohol, ether, benzol, etc., are highly explosive  
and should not be used close to a range.  
Enamel finish: Clean with warm water and detergent only.  
When discoloration occurs, use a good enamel polish such  
as automotive polish. (DO NOT use rough abrasive cleaner  
or porcelain cleaner.)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS INCLUDED WITH HOOD  
PARTS NOT INCLUDED WITH HOOD  
W
ranty  
PAR 20 50W  
Light Bulb  
Wood mounting strip  
(3 per hood)  
BR40, 250W Max.  
Warming Lamp  
(2 per hood)  
Grease Filters  
(3 per 30’’ and 36’’ hood)  
(4 per 48’’ hood)  
(5 per 60’’ hood)  
Safety  
Parts Bag  
(includes 4 flat head screws #10-2’’,  
8 screws #8-3/4’’, 4 Nuts #10-32,  
2 Wall anchors and  
Ducting Accessories  
(See “FIVESTAR Range Hood System” on page 6 for Ducting  
Accessory Model Nos.)  
2 Washers 3/16’’ ID x 3/4’’ OD)  
Blower (interior OR exterior)  
(See “FIVESTAR Range Hood System” on page 6 for Blower  
Model Nos.)  
Operation  
OPTIONAL PARTS  
Soffit Chimney  
Description  
Model Number  
FDC30-WH  
FDC30-SS  
FDC30-BL  
FDC36-WH  
FDC36-SS  
FDC36-BL  
FDC48-WH  
FDC48-SS  
FDC48-BL  
FDC60-WH  
FDC60-SS  
FDC60-BL  
30’’ White  
Backsplash  
30’’ Stainless  
30’’ Black  
36’’ White  
36’’ Stainless  
36’’ Black  
48’’ White  
48’’ Stainless  
48’’ Black  
60’’ White  
60’’ Stainless  
60’’ Black  
Description  
Model Number  
FBS30  
30’’ Stainless  
36’’ Stainless  
48’’ Stainless  
60’’ Stainless  
FBS36  
FBS48  
FBS60  
Cleaing  
TOOLS NEEDED FOR HOOD INSTALLATION  
Islation  
Screwdriver  
(Robertson or Phillips)  
Tape  
Measure  
3/8”  
Nutdriver  
Pencil  
SviceParts  
Sabre  
Saw  
Keyhole  
Saw  
Wire  
Stripper  
-or-  
Duct Tape  
Drill  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIVESTAR RANGE HOOD SYSTEM  
Wall & Roof Caps,  
Exterior Blower  
Model 647  
7’’ Round  
Wall Cap  
Model 332H  
(900 cfm)  
Exterior Blower  
Model 437  
High Capacity  
Roof Cap  
Model 441  
10’’ Round  
Wall Cap  
Model 634  
or 644  
Roof Cap  
Elbows and  
In-Line Dampers  
Model 421  
10’’ Round Vertical  
In-Line Damper  
Model 415  
7’’ Round  
Adjustable Elbow  
Model 418  
10’’ Round  
Adjustable Elbow  
Ductwork  
Model 410  
10’’ Round Duct  
(2 ft. sections)  
Model 407  
7’’ Round Duct  
(2 ft. sections)  
Choose 1 of 5  
Discharge  
Transitions  
Model 427  
Model 423  
Model 424  
Model 454  
(4 ½’’ x 18 ½’’  
Model 453  
(4 ½’’ x 18 ½’’  
(4 ½’’ x 18 ½’’ (4 ½’’ x 18 ½’’ to (4 ½’’ x 18 ½’’  
to 10’’ Rd.,  
6’’ high - lateral)  
10’’ Rd., - vertical) to 10’’ Rd., Horiz. to 10’’ Rd., Horiz. to 10’’ Rd., Horiz.  
front - rear)  
Horiz. / right)  
Horiz. / left)  
Optional  
FDC Series  
Soffit Chimney  
(See page 5 for  
model numbers)  
Model 332KR  
Rough-in Kit  
(Use with Exterior  
Blower Model 332H)  
Model FBK600  
Blower /  
Rough-in Kit  
(600 cfm Interior  
Blower and  
Choose 1 of 3  
Blower Systems  
Hood  
(Canopy with blower  
controls & lighting.  
Required for all  
installations.)  
Rough-in Plate)  
Model FBK1200  
Blower / Rough-in Kit  
(1200 cfm Interior Blower and  
Rough-in Plate)  
Optional FBS Series Backsplash  
(Stainless steel wall covering  
with warming shelves.)  
FIVESTAR MODELS available through your local FIVESTAR  
store or from FIVESTAR Parts at  
HL0033  
(See page 5 for model numbers.)  
1-800-553-7704.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARE THE HOOD LOCATION  
Wranty  
1. The FIVESTAR hood must be installed with interior blower  
2. Dimensions for the most common installations are shown  
below.  
models FBK600 or FBK1200, or exterior blower model  
332H only. Other blowers cannot be substituted. (Blowers  
sold separately.)  
Plan where and how the ductwork will be located.  
Install proper-sized ductwork, transition(s), elbow(s), and  
roof or wall cap for the model of blower you are using.  
Adjust your measurements for various heights of ceilings,  
soffits, cabinets or cooktops. For proper operation, the  
hood must be a minimum of 24” and a maximum of 30”  
above the cooktop.  
For best results, use a minimum number of transition  
and elbows.  
Standard  
8 ft. (2.44 m)  
ceiling  
S
t
a
nd  
457 mm  
ve oo  
ca  
a
r
d
18  
"
18"  
(457 mm)  
ROOF CAP  
(
)
t
H
op  
o
r-  
c
k
e
19"  
(483 mm)  
7" (178 mm)  
ROUND DUCT  
Safety  
b
i
n
t
Top of wood  
mounting strip  
DECORATIVE  
FLUE  
or SOFFIT  
12"  
(305 mm)  
WALL CAP  
Hood  
HOOD  
7" (178 mm)  
ROUND  
ELBOW  
FBS  
24" TO 30" (609 to 762 mm)  
ABOVE COOKING SURFACE  
RMP Series  
Backsplash  
(optional)  
Operation  
HH0024A  
24"  
Minimum distance  
between the hood and  
the cooktop  
(610 mm)  
MODEL FBK600 SINGLE BLOWER  
TYPICAL DUCTWORK  
Standard 36"  
(914 mm)  
ROOF CAP  
Cooktop  
H cooktop  
HH0028A  
10" (254 mm)  
ROUND DUCT  
INSTALLATION WITH STANDARD 18’’ HIGH  
OVER-COOKTOP CABINET  
Cleaing  
WALL CAP  
DECORATIVE  
12"  
FLUE  
or SOFFIT  
(305 mm)  
4-1/2" x 18-1/2"  
to 10"  
HOOD  
(114 x 470 to  
254 mm) ROUND  
TRANSITION  
(see page 4)  
FDC  
24" TO 30" (609 to 762 mm)  
ABOVE COOKING SURFACE  
HH0025A  
MODEL FBK1200 DUAL BLOWER  
TYPICAL DUCTWORK  
Islation  
EXTERIOR BLOWER  
10" (254 mm)  
ROUND DUCT  
FBS  
DECORATIVE  
FLUE  
10" (254 mm)  
ROUND ELBOW  
12"  
Maximum distance  
between the hood and  
the cooktop  
or SOFFIT  
(305 mm)  
EXTERIOR  
BLOWER  
SviceParts  
HOOD  
332KR  
ROUGH-IN KIT  
24" TO 30" (609 to 762 mm)  
ABOVE COOKING SURFACE  
INSTALLATION WITH 12’’ SOFFIT OR  
HH0026A  
OPTIONAL SOFFIT CHIMNEY FDC SERIES  
MODEL 332H EXTERIOR BLOWER  
TYPICAL DUCTWORK  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARE THE HOOD  
1. Using a Phillips #2 or a Robertson #2 screwdriver,  
unscrew the hood from the bottom of crate. Refer to figure  
to the right to locate all 4 screws. Discard these screws  
and remove hood from wood pallet.  
4
2
3
1
HR0002  
OPTION  
A Backsplash is available (see page 5 for more details). This  
backsplash must be installed before the hood shell because  
the hood shell covers the backsplash top mounting screws.  
In order to be able to install the backsplash, make sure you  
have at least 18” (457 mm) clearance between bottom of  
hood and range control panel or cooktop. (Refer to instructions  
included with backsplash.)  
2. Measure and mark a level line on wall above cooktop  
location for the wood mounting strip (see illustrations  
to the right and under step 2 on page 7). Use #10-2” flat  
head screws (included in the parts bag) to secure the  
mounting strip to the drywall. Make sure to hit the wall studs.  
CAUTION: Due to the weight of this hood,  
ensure that the wood strip is attached to all of  
7
!
the available wall studs (2 studs minimum for  
the 30hood, more as hood width increases);  
not into drywall alone.  
1. Drywall  
2. Wood Mounting Strip  
3. Flat Head Screw  
4. Wall Anchor Location  
5. Outline of the Back of the Hood  
6. Wall Studs  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALL THE HOOD  
Wranty  
1. Rest the back cavity of the hood on the wood mounting  
strip.  
Top of hood (inside view)  
Mounting screw locations  
CAUTION: Hold the hood until it is completely  
!
secured to the wood mounting strip.  
Secure hood to wood strip with (4) screws #8 - 3/4” (for  
30” and 36” width hoods) or (6) screws (for 48” and 60’’  
width hood) provided at location shown. Drill (2) 3/16” size  
holes into the drywall for wall anchors through the existing  
holes in the inside hood back in the locations shown. Then  
install the (2) wall anchors and attach the hood to these  
anchors with the remaining #8 - 3/4” screws and the (2)  
washers provided.  
Back of hood (inside view)  
Wall anchor locations  
Safety  
HD0064  
2. Attach transition (if required) to blower rough-in plate.  
Refer to page 6 for available model numbers.  
Use duct tape to make all joints secure and air-tight.  
NOTE  
Operation  
Model FBK600 blower plate connects directly to 7” round  
duct without a transition.  
The exterior blower model 332H utilizes a model 332KR  
mounting plate which connects directly to 10” round ductwork  
without a transition.  
HD0049  
3. Run power cable to installation location. Refer to the  
instructions included with the selected blower / rough-in  
kit (sold separately) for details on installing the rough-in  
plate. Install the rough-in plate so that the wiring box is  
located on the right side as you are facing the hood.  
Cleaing  
Plate on top of hood  
Locknuts  
For ducting through back of hood, remove existing plate  
from inside back of hood and attach to inside top of hood  
to cover hole. Secure to threaded studs with same (4)  
nuts.  
Rough-in plate on back of  
hood  
Wiring  
cover  
For ducting through top of hood, existing plate remains in  
place on inside back of hood.  
Connect ducting to transition or rough-in plate as you are  
installing the rough-in plate. Use duct tape to make all  
joints secure and air-tight.  
Locknuts  
Islation  
HD0063  
SviceParts  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECT THE WIRING  
1. Remove wiring cover from rough-in plate and set aside.  
WARNING: Risk of electrical shock. Electrical  
wiring must be done by qualified personnel  
in accordance with all applicable codes and  
standards. Before connecting wires, switch  
power off at service panel and lock service  
disconnecting means to prevent power from  
being switched on accidentally.  
2. Remove appropriate knock-out from rough-in plate. As you  
are installing the rough-in plate, feed 6” of power cable  
through knock-out opening and attach cable to wiring box  
with appropriate connector.  
3. Connect BLACK to BLACK, WHITE to WHITE and GREEN  
or bare wire under GREEN ground screw. Reinstall wiring  
cover.  
WIRING DIAGRAM  
RIGHT HEAT LAMP SWITCH  
RIGHT HEAT LAMP SOCKET  
B
120V 60Hz IN  
W
TO FAN MOTOR  
B
B
NEMA  
5-15P PLUG  
B
W
FAN SWITCH  
G
HS  
W
THERMOSTAT  
SPEED  
CONTROL  
B
RIGHT LIGHT  
SOCKET  
W
B
LIGHT  
W
B
SWITCH  
B
B
CENTER LIGHT SOCKET  
B
W
LEFT LIGHT SOCKET  
LEFT HEAT  
LAMP SWITCH  
B
W
LEFT HEATLAMP SOCKET  
B
W
TERMINAL BLOCK  
W
W
W
W
W
W
W
FINALIZE THE INSTALLATION  
OPTION  
A Soffit Chimney is available - to hide ductwork if the hood  
is not installed under a cabinet. Refer to the instructions  
included with the soffit chimney.  
Refer to page 5 for ordering information.  
1. To install blower, refer to instructions included with blower  
/ rough-in kit. Once the blower is installed, plug the blower  
unit into the female receptacle and the power supply onto  
the male connector inside the hood. DO NOT plug the two  
cords into each other.  
See page 6 for blower / rough-in kit information.  
HE0003  
2. Install (2) heat lamp bulbs. Use BR40 size, 250W Max.,  
infrared bulbs only (purchase separately).  
Install (3) halogen light bulbs. Use PAR20 50W size  
(purchase separately).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALL FILTERS  
Wranty  
CAUTION:Remove protective plastic film covering  
!
filters before installing them.  
It is recommended to install side filters first and finish with  
center one(s).  
1) Insert upper end of filter into the hood (pull tab side).  
2) Raise lower end toward the inside of hood.  
3) Position rear part of filter into channel and pull.  
4) Using the pull tab, pull on the upper end of filter and slide it  
under the front inner retaining piece.  
Safety  
1
2
Operation  
HD0070  
4
3
Cleaing  
HD0024  
Replacement filters are available.  
Refer to page 12 for ordering information.  
Islation  
SviceParts  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE PARTS  
1
20  
19  
21  
17  
18  
11  
20  
14  
4
16  
12  
3
22  
6
13  
5
15  
7
8
7
10  
2
9
2
HL0031  
KEY NO. PART NO.  
DESCRIPTION  
KEY NO. PART NO.  
DESCRIPTION  
17  
V05663  
V05663  
V05663  
Mesh Filter for 36” Hood  
11.61 x 15.25 x 0.355 (3 required)  
Mesh Filter for 48” Hood  
11.61 x 15.25 x 0.355 (4 required)  
Mesh Filter for 60” Hood  
11.61 x 15.25 x 0.355 (5 required)  
Grease Rail 30”  
1
2
3
4
5
6
7
V05616  
V02264  
V02773  
V02772  
V03435  
V03436  
V02563  
FIVESTAR Logo  
Porcelain Lamp Socket  
Male Motor Connector  
Female Motor Connector  
Thermostat  
Thermostat Bracket  
SPST Single Switch for  
Heat Lamps  
SPST Double Switch for  
Halogen Lights  
SPST Lighted Single Switch  
for Blower  
Speed Control Button  
Speed Control  
Terminal Block  
Power Cord  
Control Wire  
Lighted Switch Wire  
Lock Nut 8-32  
18  
V14763  
V14764  
V14766  
V14768  
V05528  
V05521  
V14744  
V14745  
V05650  
V12971  
Grease Rail 36”  
Grease Rail 48”  
Grease Rail 60”  
Filter Spring 5.265” x 0.350”  
Sealing Extrusion 20.625”  
Left Side Liner  
Right Side Liner  
Manual for Five Star  
Installation Bag (Flat head screws  
#10 x 2” (4), Screws #8 x 3/4” (8),  
Nuts #10-32 (4), Wall anchors (2),  
Washers 3/16” ID x 3/4” OD (2))  
Halogen Lamp PAR20 50W  
Heat Lamp BR40, 250W max.  
8
9
V03502  
V03503  
19  
20  
21  
22  
**  
10  
11  
12  
**  
**  
**  
13  
14  
15  
16  
17  
V03504  
V03501  
V03505  
V03517  
V03519  
V03520  
V00673  
V02512  
V01869  
V01582  
V05662  
**  
**  
*
V02544  
Machine Screw 8-32 x ½ Quadrex  
MachineScrew6-32PanQuadrex  
Lock Nut 6-32  
Mesh Filter Kit for 30” Hood  
9.5 x 15.25 x 0.355 (QTY:3)  
Order replacement parts by PARTNO. - not by KEY NO.  
* Purchased locally.  
** Not illustrated.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Continental Kitchen Grill CM43505 User Manual
Craftsman Air Compressor 919722020 User Manual
Creda Oven REFLECTION User Manual
Curtis Flat Panel Television KCR2610A User Manual
Dymo Label Maker LT 100T User Manual
Electro Voice Microphone 633 User Manual
Everpure Water System DEV9108 25 User Manual
Frigidaire Oven 318205116 User Manual
GE Monogram Range ZGU486LDPSS User Manual
Gigabyte Network Card GA K8VT890 9 User Manual