Residential & Light Commercial HVAC
Split System Heat Pump
11⁄
208/230 Volt, 1-Phase, 60 Hz
2
thru 5 Tons
Performance:
Efficiency rating of 13 SEER
Cooling capacities from 11⁄
to 5 tons
2
Refrigerant Circuit:
Factory installed biflow liquid line filter drier
Long life copper tubes, aluminum fins
State-of-the-art compressors
Large, wrap-around coil surface
Quality Built:
Galvanized steel exterior cabinet with
1,000-hour salt spray, powder-coated finish
Powder-coated fan guard
Full louvered panel to protect coil
Formed base with 21⁄2" ground clearance
Limited 5-year warranty on parts
Low pressure port
Integrated solid state control with adjustable
time-temp demand defrost
Easy To Install:
Rated in Accordance with ARI Standard
210/240. Certification Applies Only When Used
with Proper Components as Listed with ARI.
Additional rating information can be found
Factory-charged
Only three screws to access electrical controls
Easy access to service valves
Size
2Max. Fuse
Model
Number
Nominal
BTUH
Min. Circuit
Ampacity
Operating Dimensions
H x W x D (inches)
Min. Mounting Ship / Operating
Refrigerant
Pad Size (inches)
Weight (lbs)
(tons)
or Breaker
1
1
1
1
2
CH18ABD1VF
CH24ACD1VF
CH30ACD1VF
CH36ACD1VF
CH42ACD1VF
CH48ACD1VF
CH60ACZ1VF
1 ⁄2
R-22
R-22
18,000
24,000
30,000
36,000
42,000
48,000
60,000
13.5
16.0
18.8
20.5
24.8
27.3
38.4
20
25
30
35
40
45
60
32 ⁄2 X 21 ⁄2 X 21 ⁄
24 x 24
32 x 32
32 x 32
32 x 32
32 x 32
32 x 32
32 x 32
132 / 127
195 / 186
195 / 186
197 / 188
208 / 201
212 / 203
258 / 249
1
1
1
2
2
32 ⁄2 X 29 ⁄2 X 29 ⁄
1
1
1
1
2
2 ⁄2
R-22
32 ⁄2 X 29 ⁄2 X 29 ⁄
1
1
1
2
3
R-22
32 ⁄2 X 29 ⁄2 X 29 ⁄
1
1
1
1
2
3 ⁄2
R-22
32 ⁄2 X 29 ⁄2 X 29 ⁄
1
1
1
2
4
5
R-22
32 ⁄2 X 29 ⁄2 X 29 ⁄
1
1
R-410A
39 X 29 ⁄2 X 29 ⁄2
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications
ARI CERTIFIED COMBINATION RATINGS
COOLING
HEATING
LOW TEMP
FACTORY
UNIT
SIZE
OUTDOOR
MODEL
INDOOR
MODEL
HIGH TEMP
CAPACITY
SUPPLIED
TOTAL
CAPACITY
SEER
EER
HSPF
ENHANCEMENT
COP
3.42
3.42
3.42
3.50
3.50
3.42
3.42
3.42
3.42
CAPACITY
11,100
11,100
15,000
18,200
22,000
23,000
23,000
28,400
38,000
COP
2.36
2.36
2.20
2.30
2.50
2.30
2.30
2.50
2.30
CH18ABD1VF AFPB24A1
CH18ABD1VF AFPB24B1
CH24ACD1VF AFPB24B1
TXV, TDR
TXV, TDR
TXV, TDR
TXV, TDR
TXV, TDR
TXV, TDR
TXV, TDR
TXV, TDR
TXV, TDR
18,000
18,000
24,000
28,000
34,000
40,000
40,000
46,000
56,000
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
11.0
11.0
11.4
11.5
11.5
11.5
11.5
11.5
11.2
17,300
17,300
24,000
28,000
34,000
40,000
40,000
44,000
56,000
8.2
8.2
8.2
8.2
8.2
8.2
8.2
7.8
8.2
18
24
30 CH30ACD1VF
AFPB36A1
36
42
CH36ACD1VF AFPB36A1
CH42ACD1VF AFPC48A1
CH42ACD1VF AFPC48B1
CH48ACD1VF AFPC48B1
CH60ACZ1VF AZFPC60B1
48
60
SEER – Seasonal Energy Efficiency Ratio
COP – Coefficient of Performance
TDR – Time – Delay Relay
HSPF – Heating Seasonal Performance Factor
EER – Energy Efficiency Ratio
NOTES:
1. Tested combination per ARI 210/240 standard. Fedders air handlers contain the TDR as standard equipment.
2. Supplemental electric heat is not included.
3. Ratings are based on:
Cooling Standard: 80ºF db 67ºF wb indoor entering air temperature and 95ºF db air entering outdoor unit.
High – Temp Heating Standard: 70ºF db indoor entering air temperature and 47ºF db 43ºF wb air entering outdoor unit.
Low – Temp Heating Standard: 70ºF db indoor entering air temperature and 17ºF db 15ºF wb air entering outdoor unit.
3
Specifications subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
Split System Heat Pump
LINE SET LENGTH AND SIZE
SUCTION LINE SIZES
LIQUID LINE SIZES
25 ft. 50 ft.
3/8 3/8
BTUH
15 ft.
3/4
25 ft.
3/4
50 ft.
3/4
75 ft.
3/4
15 ft.
3/8
3/8
3/8
3/8
3/8
3/8
3/8
75 ft.
3/8
3/8
3/8
3/8
1/2
1/2
1/2
18
24
30
36
42
48
60
3/4
3/4
3/4
3/4
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/4
7/8
7/8
7/8
3/4
7/8
7/8
7/8
7/8
7/8
7/8
7/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
Recommended liquid & suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and
15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied
by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet
vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)
Note: See unit installation instructions for proper installation.
COOLING PERFORMANCE DATA
RATINGS AT STANDARD CONDITIONS
COOLING DATA AT EXTENDED OUTDOOR AMBIENTS F.M.B.T.U.H.
OUTDOOR
UNIT
MODEL
AIR
HANDLER
BTUH
CFM
80
85
90
95
100
105
110
115
SEER*
TOTAL
SENSIBLE
TOTAL
19,450
15,250
25,800
19,900
30,050
23,100
36,350
28,300
42,700
33,250
49,300
40,950
60,550
44,550
18,900
14,950
25,150
19,500
29,450
22,600
35,500
27,850
42,550
32,900
48,150
39,750
59,000
43,950
18,450
14,600
24,600
19,050
28,750
22,050
34,800
27,650
40,950
32,100
46,950
38,100
57,450
43,100
18,000
14,200
24,000
18,700
28,000
21,700
34,000
27,250
40,000
31,500
46,000
36,000
56,000
42,350
17,650
14,050
23,450
18,450
27,200
21,450
33,250
26,950
39,000
30,550
44,850
34,800
54,300
41,700
17,200
13,800
22,900
18,000
26,550
21,050
32,550
26,750
38,000
29,600
43,650
33,550
52,450
40,950
16,750
13,500
22,350
17,650
25,800
20,800
31,700
26,350
37,400
28,450
42,500
32,350
51,100
40,500
16,400
13,250
21,950
17,300
25,250
20,550
30,950
26,050
36,800
27,600
41,400
31,150
49,850
39,600
CH18ABD1VF
CH24ACD1VF
CH30ACD1VF
CH36ACD1VF
CH42ACD1VF
CH48ACD1VF
CH60ACZ1VF
AFPB24A1
AFPB24B1
AFPB36A1
AFPB36A1
AFPC48A1
AFPC48B1
AZFPC60B1
18,000
13
650
24,000
28,000
34,000
40,000
46,000
56,000
13
13
13
13
13
13
840
SENSIBLE
TOTAL
1,000
1,200
1,350
1,550
1,750
SENSIBLE
TOTAL
SENSIBLE
TOTAL
SENSIBLE
TOTAL
SENSIBLE
TOTAL
SENSIBLE
*TDR required to obtain SEER rating.
4
Specifications subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
Split System Heat Pump
5
Specifications subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
Split System Heat Pump
Residential & Light Commercial
13 SEER Split System
Model Number Identification
CH 24 A B D 1 V F * A
Product Type
C = Air Conditioner
CH = Heat Pump
Brand
Fitting Type
V = Sweat
Nominal Capacity
18 = 18,000 BTUH [5.28 kW]
24 = 24,000 BTUH [7.03 kW]
30 = 30,000 BTUH [8.79 kW]
36 = 36,000 BTUH [10.55 kW]
42 = 42,000 BTUH [12.31 kW]
48 = 48,000 BTUH [14.07 kW]
60 = 60,000 BTUH [17.58 kW]
Electrical Designation
1 = 208 / 230 Volts, 1 Phase, 60 Hz
2 = 220 Volts, 1 Phase, 50 Hz
3 = 208 / 230 Volts, 3 Phase, 60 Hz
4 = 460 Volts, 3 Phase, 60 Hz
5 = 230 Volts, 3 Phase, 50 Hz
6 = 380 Volts, 3 Phase, 50 Hz
Series
Chassis Size
Refrigerant Variations
D = R-22 Refrigerant
Z = R-410A Refrigerant
B = 211⁄2" W x 211⁄2" D x H - Determined by BTU Size
C = 291⁄2" W x 291⁄2" D x H - Determined by BTU Size
Fedders Corporation
505 Martinsville Rd.
Liberty Corner, NJ 07938 USA
(908) 604-8686
All product specifications reflect available information at the printing of this brochure.
Fedders reserves the right to revise or modify products and/or specifications without notice.
Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.
FD-017-0507-m
Form No. F-CH13
6
Specifications subject to change without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
|