Selecting A Mounting locAtion  
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights  
of the Insurice Systems are:  
• Single System - 9 lbs. (4.0 kg.)  
• Twin System - 19 lbs. (8.5 kg)  
• Triple System - 27 lbs. (12 kg)  
• Quad System - 36 lbs. (20 kg)  
2. The location should allow for:  
• Minimum clearance of 2-1/2” under the cartridge(s) so it can be lowered for removal and re-  
placement.  
• Adequate space for “in” and “out” water line connections.  
• Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard  
Low Pressure Alarm is used. See Figures 1-4.  
Figure 1 – Insurice Single System  
Figure 2 – Insurice Twin System  
Figure 3 – Insurice Triple System  
3. If possible, keep at least 6” available to the left and the right of the Insurice System in the event  
poor quality water conditions require the installation of the optional Everpure K-Series Prefilter.  
operAting SpecificAtionS*  
replacement  
cartridge  
combined Model name  
flow rate  
capacity  
Insurice Single - i2000  
Insurice Single - i20002  
Insurice Single - i4000  
Insurice Single - i40002  
Insurice Twin - i2000  
Insurice Twin - i20002  
Insurice Twin - i4000  
Insurice Twin - i40002  
Insurice Triple - i2000  
Insurice Triple - i20002  
Insurice Triple - i4000  
Insurice Triple - i40002  
Insurice Quad - i2000  
Insurice Quad - i20002  
Insurice Quad - i4000  
Insurice Quad - i40002  
i2000  
1.67 gpm (6.3 lpm) 9,000 gal (34,000 L)  
1.67 gpm (6.3 lpm) 9,000 gal (34,000 L)  
1.67 gpm (6.3 lpm) 12,000 gal (45,420 L)  
1.67 gpm (6.3 lpm) 12,000 gal (45,420 L)  
3.3 gpm (12.6 lpm) 18,000 gal (68,000 L)  
3.3 gpm (12.6 lpm) 18,000 gal (68,000 L)  
3.3 gpm (12.6 lpm) 24,000 gal (90,840 L)  
3.3 gpm (12.6 lpm) 24,000 gal (90,840 L)  
5.0 gpm (18.9 lpm) 27,000 gal (102,000 L)  
5.0 gpm (18.9 lpm) 27,000 gal (102,000 L)  
5.0 gpm (18.9 lpm) 36,000 gal (136,260 L)  
5.0 gpm (18.9 lpm) 36,000 gal (136,260 L)  
i20002  
i4000  
i40002  
i2000  
i20002  
i4000  
i40002  
i2000  
i20002  
i4000  
i40002  
i2000  
i20002  
i4000  
i40002  
6.6 gpm (25 lpm)  
6.6 gpm (25 lpm)  
6.6 gpm (25 lpm)  
6.6 gpm (25 lpm)  
36,000 gal (136,260 L)  
36,000 gal (136,260 L)  
48,000 gal (181,680 L)  
48,000 gal (181,680 L)  
* For individual cartridge specifications, refer to cartridge literature.  
temperature: 35-100°F (2-38°C)  
pressure:  
10 - 125 psi (0.7 - 8.6 bar), non-shock  
For cold water use only.  
Figure 4 – Insurice Quad System  
Manufactured by Everpure  
EV3112-81 Rev E AP08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
replAceMent pArtS  
System Tested and Certified by NSF International against  
NSF/ANSI Standards 42 and 53 for the reduction of:  
Contact your local Everpure dealer for filter cartridges or system  
replacement parts.  
Standard No. 42 —  
Aesthetic Effects  
Chemical Reduction  
Taste and Odor  
Chlorine  
Mechanical Filtration  
Particulate Class I: 99.2% reduction of particles  
one-half micron and larger in size  
description  
part number  
EV3114-09  
EV3114-09  
EV3114-07  
EV3114-07  
Outlet pressure gauge  
Inlet pressure gauge (quad only)  
Inlet valve (twin, triple & quad)  
Flushing valve  
Standard No. 53 —  
Health Effects  
Mechanical Filtration  
Turbidity (i2000, i20002 Only)  
Cyst  
Asbestos (i2000, i20002 Only)  
preSSure gAugeS  
Adequate Outlet  
Pressure  
Low Inlet  
Pressure  
Adequate Inlet  
Pressure  
Low Outlet  
Pressure  
cArtridge chAnge procedure  
flushing  
4. Pull cartridge downward and out of  
everpure carbon filter cartridge  
change  
2. Open flushing valve to relieve  
pressure.  
head.  
6. Turn cartridge right 90˚ until  
rotation stops.  
8. With flushing valve fully open, open  
inlet water at full force for five  
minutes. Close flushing valve.  
5. Hold head firmly. Align cartridge  
lug with label. Insert new cartridge  
firmly into head.  
1. Shut off power to equipment. Shut  
off inlet water ahead of system.  
3. Hold head firmly and push upward.  
Turn cartridge to left until it stops.  
7. Repeat steps 3-6 for remaining  
cartridges.  
9. Turn on power to equipment  
for installations in Massachusetts, the commonwealth of Massachusetts plumbing code 248 cMr shall be adhered to. consult your licensed  
plumber for installation of the system. this system and its installation must comply with state and local regulations.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
liMited WArrAnty  
coMMerciAl WAter treAtMent equipMent  
You have just purchased one of the finest water treatment units made. As an expression of our confidence in Everpure products, this product is warranted against defects in  
material and workmanship to the original end-user when installed in accordance with Everpure specifications. The warranty period commences from the date of purchase  
and is administered as follows:  
for a period of one yeAr  
for a period of fiVe yeArS  
replaceable elements (i.e., filter & water treatment cartridges)*  
the entire system (excluding replaceable elements)  
*this is for material & workmanship, not lter or water treatment cartridge life.  
The unit must be used in operating conditions that conform to Everpure’s recommended design guidelines. This warranty will not apply if the unit has been modified, repaired  
or altered by someone not authorized by Everpure.  
if a part described above is found defective within the specied period, you should notify everpure technical service at the phone number listed below. Any part  
found defective within the terms of this warranty will be repaired or replaced (at everpure’s discretion) by your local dealer or everpure technical service. you  
pay only freight from our factory and local dealer charges. Any repaired or replaced warranty item will be incorporated under the original warranty terms of the  
existing system.  
We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing agents (such as chlorine, ozone,  
chloramines and other related components), alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not  
meet Everpure’s specifications. Refer to the specifications section in the Installation and Operating manual for approved application parameters.  
Our product performance specifications are furnished with each water treatment unit. TO THE EXTENT PERMITTED BY LAW, EVERPURE DISCLAIMS ALL IMPLIED WARRANTIES,  
INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE EXTENT REQUIRED BY LAW, ANY SUCH IMPLIED  
WARRANTIES ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR THE ENTIRE WATER TREATMENT UNIT. As a manufacturer, we do not know the characteristics  
of your water supply or the purpose for which you are purchasing this product. The quality of water supplies may vary seasonally or over a period of time, and your water  
usage rate may vary as well. Water characteristics can also differ considerably if this product is moved to a new location. For these reasons, we assume no liability for the  
determination of the proper equipment necessary to meet your requirements, and we do not authorize others to assume such obligations for us. Further, we assume no  
liability and extend no warranties, express or implied, for the use of this product with a non-potable water source or a water source which does not meet the conditions for  
use described in the owner’s guide or performance data sheet for this product. OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT  
(AT EVERPURE’S DISCRETION) OF THE FAILED PARTS OF THE WATER TREATMENT UNIT, AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT, INDIRECT, INCIDENTAL,  
CONSEQUENTIAL, SPECIAL, GENERAL OR OTHER DAMAGES.  
Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Similarly,  
some states do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific  
legal rights, and you may also have other rights which vary from state to state. Consult your telephone directory for your local independently operated Everpure dealer, or  
write Everpure for warranty and service information.  
for sales, replacement components, and service, contact your everpure dealer or:  
everpure, llc: 1040 Muirfield Drive • Hanover Park, Illinois 60133 • 800.323.7873  
in europe: Toekomstlaan 30 • B-2200 Herentals, Belguim  
technical Service  
800.942.1153  
in Japan: Hashimoto MN Bldg. 7F • 3-25-1 Hashimoto Sagamihara-Shi • Kanagawa 229-1103, Japan  
Printed in U.S.A.  
EV3112-81 Rev E AP08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Lighting Indoor Furnishings 1 85 QL User Manual
Cooper Lighting Work Light AEL1SD User Manual
Craftsman Blower 358748200 User Manual
Dynalink Universal Remote A 1012 User Manual
Electro Voice Microphone N D308B User Manual
Everex Laptop LM7WB User Manual
Fellowes Paper Shredder MS 450Cs User Manual
Frigidaire Washer FFTW1001PW User Manual
Generac Power Systems Portable Generator 004917 3 User Manual
Gigabyte Network Card GN MD01 User Manual