| 20" (50.8 cm) Freestanding Electric Range   PRODUCT MODEL NUMBERS   PRODUCT DIMENSIONS   TEP200VA   TEP222VA   Electrical: If codes permit and a separate ground wire is   used, it is recommended that a qualified electrical installer   determine that the ground path is adequate and wire   gauge is in accordance with local codes.   Range Rating*   Specified Rating of   Power Supply Cord Kit   and Circuit Protection   120/240 Volts 120/208 Volts   Amps   D A 8.0 - 16.5 KW 6.0 - 12.5 KW   40 or 50**   16.6 - 22.5 KW 12.6 - 18.5 KW 50   *The NEC calculated load is less than the total   connected load listed on the model/serial rating plate.   **If connecting to a 50-amp circuit, use a 50-amp rated   cord with kit. For 50-amp rated cord kits, use kits that   specify use with a nominal 1-3/8" (34.9 mm) diameter   connection opening.   C B A circuit breaker is recommended.   The range can be connected directly to the circuit breaker   box (or fused disconnect) through flexible or nonmetallic   sheathed, copper or aluminum cable.   A. 36" (91.5 cm)   B. 19½" (49.5 cm)   C. 24½" (62.2 cm)   D. 42" (106.7 cm)   The model/serial rating plate is located under the left front   burner bowl.   CABINET OPENING DIMENSIONS   Cabinet opening dimensions shown are for:   B 25" (63.5 cm) countertop depth   24" (61.0 cm) base cabinet depth   36" (91.4 cm) countertop height   F C D IMPORTANT: If installing a range hood or microwave   hood combination above the range, follow the range hood   or microwave hood combination installation instructions   for dimensional clearances above the cooktop surface.   A E NOTE: 24" (61.0 cm) minimum when bottom of wood or   metal cabinet is covered by not less than 1/4" (0.64 cm)   flame retardant millboard covered with not less than No.   28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,   0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.   G G 30" (76.2 cm) minimum clearance between the top of the   cooking platform and the bottom of an uncovered wood   or metal cabinet.   H To eliminate the risk of burns or fire by reaching over   heated surface units, cabinet storage space located above   the surface units should be avoided. If cabinet storage is   to be provided, the risk can be reduced by installing a   range hood that projects horizontally a minimum of 5"   (12.7 cm) beyond the bottom of the cabinets.   A. 18" (45.7 cm) min. clearance   upper side cabinet to   countertop   E. 5" (12.7 cm) min. countertop   space to side wall or other   combustible material   B. 13" (33.0 cm) max. upper   cabinet depth   F. For minimum clearance to top   of cooktop, see NOTE.   C. 20" (50.8 cm) min. cabinet   opening width   G. Wall receptacle - 8" (20.3 cm)   from either cabinet,   D. 20¹⁄₈" (51.1 cm) opening width   H. 5½" (14.0 cm) max. from floor.   Locate 120/240-volt   receptacle in shaded area.   Because Whirlpool Corporation policy includes a continuous commitment to improve our   products, we reserve the right to change materials and specifications without notice.   Dimensions are for planning purposes only. For complete details, see Installation   Instructions packed with product. Specifications subject to change without notice.   Ref. W10175654B   08-27-08   Download from Www.Somanuals.com. All Manuals Search And Download.   |