Installation Instructions
Sample Wiring Configurations
1
Ensure that the location and intended use meet the following criteria:
Two-Location Scenario—Power Source at Wall Box
Single-Location Scenario—Power Source at Wall Box
• The range and performance of the wireless control system is highly
dependent on the following: (1) distance between devices; (2) layout of the
home; (3) walls separating devices; and (4) electrical equipment located near
devices.
Note: This device will not function without a neutral AC connection.
Note: This device will not function without a neutral AC connection.
To wire the switch and a multi-button keypad in a two-location scenario
(Escient’s 3-way-switch solution) where the power is first routed to the wall
box, do the following:
To wire the switch for a Escient single-location scenario in which the power is
first routed to the wallbox, use a 4-position terminal connector to connect the
wires indicated in the following table (illustrated in Figure 2):
• DO NOT exceed maximum load rating of switch (which is 1000 Volt for a
single unit).
WARNING! Disconnect power before installing or servicing the
device.
1. Wire the switch into Wall Box #1 by using a 4-position terminal connector
Wires in the Wall Box
Switch Wires
LS102
Wireless Switch
Installation
Guide
From Power Source
Blue (neutral)
To Light Fixture
Blue (neutral)
Brown (load)
None
2
3
Switch off and isolate the mains power at the main consumer
unit or fuse box before starting any installation or maintenance
work.
Blue (neutral)
Red (load)
Wires in Wall Box 1
Switch Wires
None
From Power
Source
To Light Fixture
To Wall Box 2
Brown (live)
Brown (live)
Green with Yellow
(protective earth, E,
Green with Yellow (earth,
Green with Yellow
Blue (neutral)
Red (load)
Blue (neutral)
None
Blue (neutral)
Brown (load)
None
Blue (neutral)
None
Prepare the wall box and wires:
E, or
)
(earth, E, or
)
or
)
• Ensure a 4-position terminal block is installed in the box.
• Strip each wire’s insulation back 7.3 mm (0.287 in.) from the wire end (as
shown).
Brown (live)
Brown (live)
Brown (traveler)
Green with
Green with
Green with
Green with
Yellow (earth,
Yellow (earth,
Yellow (earth,
Yellow (earth,
E, or
)
E, or
)
E, or
)
E, or
)
Supported Models and Requirements
2. Wire the multi-button keypad into Wall Box #2 by using a 3-position (or
greater) terminal connector to connect the following wires (illustrated in
Europe: EFLS102/N1W | UK: EFLS102/N1W
This device requires a neutral AC connection.
This device requires a 4-position terminal block in its wall box.
Multi-Button Keypad Wires
Blue (neutral)
Wires in Wall Box 2 (from Wall Box 1)
Blue (neutral)
Green with Yellow (earth, E, or
Brown (traveler)
)
Green with Yellow (earth, E, or
Brown (traveler)
)
Specifications and Supported Fixtures
This switch operates independently or as a device you can control with your
Escient® system. It installs in a standard wall box using typical wiring
standards and communicates to the Escient system using a wireless
connection. The specifications and supported fixtures are described below.
Figure 1. Strip Wire Insulation
WARNING! This is a Class 1 product and must be Earthed.
Power:
220-240 VAC 50/60 Hz
1.49 W-LEDs Off
1.77 W-LEDs On
4
Identify and connect switch wires to the wall box wires. Wall box wires
can differ depending upon how the box was wired by the electrician and
where the power source comes from—either the light fixture or the wall
box. Refer to “Sample Wiring Configurations”.
Wiring:
Requires a neutral AC connection
Figure 2. Wiring: Power Source at Wall Box
Supported Load
Types and Ratings:
220-240 VAC 1000VA Magnetic low voltage
220-240 VAC 1000VA Electronic low voltage
Operating
Temperature:
All load ratings are based on an ambient temperature of 25
degrees Celsius.
5
6
Fit wires back into the wall box. Bend the wires in a zigzag pattern so
that they easily fold into the wall box.
Volume:
5.0 Cubic inches
Communications:
IEEE 802.15.4, 2.4 GHz, 15-channel, spread spectrum radio
Connect the switch terminal block to the wall box wires as indicated in
WARNING! Improper use or installation can cause SERIOUS
INJURY, DEATH or LOSS/DAMAGE OF PROPERTY.
Note: Wall box wires can differ depending upon how the box was
wired by your electrician.
WARNING! Install in accordance with all national and local
electrical codes.
7
8
Secure the switch to the wall box using the screws
provided.
Figure 3. Wiring: Two-Location Scenario
WARNING! If you are not sure which wires are Hot, Neutral, Load
or Ground, have a trained electrician do the installation.
Attach the Decora-style screw-on wall plate (included).
CAUTION! Do not install to control a receptacle.
CAUTION! If you are not sure which wires are Hot, Neutral, Load or
Ground, have a trained electrician do the installation.
IMPORTANT! Using this product in a manner other than outlined in
this document voids your warranty. Further, Escient is NOT liable for
any damage incurred with the misuse of this product. See “Limited 2
WARNING! Do not turn power back on until the
wall plate is completely back in place.
9
When installation is complete, turn on the mains power.
Ensure that all LEDs on the front are lit.
IMPORTANT! Do NOT use a power screw driver to install this
device.
10
IMPORTANT! Changes or modifications not expressly approved by
Escient could void the user’s authority to operate the equipment.
Download from Www.Somanuals.com. All Manuals Search And Download.
|