| OWNER’S MANUAL   CPS 3 / CPS 4   CONTRACTOR PRECISION SERIES   Download from Www.Somanuals.com. All Manuals Search And Download.   DESCRIPTION   CONTENTS   Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9 Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11   Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20   Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21   Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24   DESCRIPTION   First of all, we would like to express our thanks and at the same time congratulate you on the decision to   buy one of our CONTRACTOR PRECISION SERIES power amplifiers.   Electro-Voice CONTRACTOR PRECISION SERIES amplifiers are made to meet the highest require-   ments of any on-the-road application. Thus they provide on-board protection against thermal and   capacitive overload, short-circuit and the occurrence of HF or DC at the output. Additionally, special   circuitry prevents the output-stage transistors from being damaged by Back-EMF. During soft start,   delayed switching of the power outputs is accomplished via relays and a limiter controls the initial current   inrush, preventing the mains fuse from being blown during the power-on operation.   The mechanical construction as well is carried out following the highest precision standards of the industry.   The robust steel chassis provides extreme rigidity and it is meant to live through any hard wearing condition   of a touring application. Thermal stability is guaranteed by two 4-Mode silently running fans that offer the   possibility to also use the amplifiers in a studio environment.   The extensive comparator circuitry constantly monitors the input and output signals and activates the   internal limiters whenever a non-linear operational state is encountered. This provides reliable protection   of the connected loudspeaker systems against overload and clipping. The sound quality of the CON-   TRACTOR PRECISON SERIES power amplifiers is superb. Using comprehensive dimensioned power   supply units with low-interference toroidal transformers gains a headroom that exceeds the nominal power   handling capacity by far. No V/I-Foldback-Limiter circuits are employed within the power amplifiers, making   it possible to operate the amps on complex loads up to ±90° phase angles without a problem.   The input facilities are carried out as balanced XLRF-type sockets while the Direct-Outs – on which the   carried-through signals are present – come as XLRM-type connectors. Using the Input Routing-switches   lets you determine if the CONTRACTOR PRECISION SERIES amplifiers are operated in DUAL (stereo)   or PARALLEL (monaural) mode; “mono-bridged” operation is also possible.   The dB-scaled level controls are to be found on the rear panel. These potentiometers guarantee precise   and reliable operation. The easy readable LED display offers quick optical information on the power   amplifiers’ momentary operational mode. For each channel individually the display shows whether they   are operational, a signal is present at the outputs, when the limiters are activated, and whether one of the   protection circuits has been engaged or not. The power outputs CANNEL A, CHANNEL B and BRIDGED   OUT are carried out as Speakon connectors. A ground-lift switch that separates the enclosure from the   appliance’s ground potential and therefore helps to eliminate ground noise loops and the mono bridged   mode switch are also located on the rear panel. In normal operation all CONTRACTOR PRECISION   SERIES power amplifiers can be used to drive loads down to 2 ohms; in bridged mode the minimal load   is 4 ohms. All amps are equipped with extremely silent running fans providing front-to-rear air circulation,   guaranteeing trouble-free operation even in smaller power amplifier rack systems.   Studying this owner’s manual carefully will provide you with further and more detailed information about   the CONTRACTOR PRECISION SERIES power amplifiers. Thus we recommend to keep on reading,   assuring you that the Electro-Voice CONTRACTOR PRECISION SERIES power amplifiers will provide   you with a lot of fun and satisfaction in your work.   9 Download from Www.Somanuals.com. All Manuals Search And Download.   FRONT PANEL   1. Level Control   To prevent unauthorized operation of the level controls on the CPS3 and CPS4, they are provided with   screwed-on protective cover lids. When shipped from the factory, the detented potentiometers are set to   their clockwise limits. Thus, the input signal is not attenuated. In case matching the input levels is required,   you first have to detach (unscrew) the cover lids to gain access to the potentiometers.   2. POWER ON INDICATION   This LED lights up when the mains switch is pressed. If it does not light up, the unit is not connected to   the mains or the mains fuse has blown.   3. INPUT INDICATION   This LED lights up if a signal is present at the power amplifier input. The indicator does not light up when   the input controls are turned down completely.   4. OUTPUT INDICATION   This LED lights up if a signal is present at the power amplifier output. The indicator goes off when the   speaker line has shorted or a protective circuit has been activated thus indicating that there is no signal   at the speaker output terminals.   5. LIMIT   This LED lights up if the limiter has been activated and the power amplifier is being operated at the clip   level. If the LED flashes briefly, this is not a cause for concern. If this LED is lit permanently, the volume   should be reduced to avoid overload damages to the connected loudspeaker systems.   6. PROTECT   When this LED lights up during operation, one of the protection circuits against over-temperature,   overload, shorted outputs, radio frequency interference or DC faults has been triggered. The cause of the   error e.g. a shorted loudspeaker line must be remedied. In case of overheating, wait a little until the   amplifier switches back to operating mode itself.   7. POWER Switch   The unit is switched on via the power switch. The loudspeaker outputs are switched on via delayed relays   so that no startup transients are audible. A current limiter prevents startup peaks on the mains line and   prevents the mains fuse from blowing.   10   Download from Www.Somanuals.com. All Manuals Search And Download.   REAR PANEL   POWER AMPLIFIER INPUTS   Parallel to the XLR-type inputs, output connectors are provided,   offering the opportunity to feed additional power amplifiers with the   same signal.   The inputs are electrically balanced with pin-assignment according to   the IEC 268 standard.   Pin-assignment of the XLR-type input connectors:   PIN 1: SHIELD   PIN 2: a, +   PIN 3: b, -   Input sensitivity is factory set to 0 dBu.   The power amplifier can be set internally to +6dBu input sensitivity or   to +26dBu gain.   INPUT ROUTING   PARALLEL MONAURAL   Setting the selector switch to the PARALLEL/MONO position puts the   channel A and channel B inputs in electrically direct parallel configu-   ration, leaving you still the possibility to control the channels’ level   settings separately, using the output controls A and B.   DUAL STEREO   When the selector switch is set to its DUAL/STEREO position both   channels are amplified individually.   11   Download from Www.Somanuals.com. All Manuals Search And Download.   REAR PANEL   POWER AMPLIFIER OUTPUT CONNECTORS   SPEAKON output connectors are provided for the power   amplifier channels A (left) and B (right).   The Bridged Out Connector for bridged operation is   sealed with a plastic cover to prevent connection errors.   LIMITER   The time constant of the built-in limiter to avoid overdri-   ving is adjustable. Position “SLOW” is the factory preset   and this should also be the normal position.   If the power amplifier is used as a MID/HI-frequency   amplifier in active multi-way systems, the limiter switch   should be set to “FAST”.   If the power amplifier is used as LOW-frequency ampli-   fier in active multi-way systems, the limiter switch should   be set to “SLOW”.   BRIDGED MODE   Slide switch to change from Normal Stereo mode to   Bridged mode. In Bridged mode the built-in power ampli-   fiers operate in “push- pull” and the double output voltage   from channel A and B appears at the Bridged output   connector. The phases of Channel A and B are in oppo-   site and therefore the individual channels must not be   used as loudspeaker outputs.   HI-LO-CUT FILTER   This filter attenuates subsonic and high frequency si-   gnals so that the power amplifiers are not modulated with   these signals. This switch should normally always be in   position ON. The OFF position is only for applications   where an upstream unit, e.g. a crossover or a equalizer,   has integrated HI-Cut and LO-Cut filters.   GROUNDLIFT SWITCH   Hum loops can be avoided with the groundlift switch. If   the power amplifier is operated together with other units   in one 19" rack, the switch should be in GROUNDED   position. If the power amplifier is used with units which   have different earthing potentials, the switch should be   adjusted to the UNGROUNDED position.   12   Download from Www.Somanuals.com. All Manuals Search And Download.   SPECIFICATIONS   Technical Specifications: CPS3, CPS4   Amplifier at rated conditions, both channels driven with 8 ohms loads, unless otherwise specified.   CPS3   CPS4   Load Impedance   8 W   4 W   2 W   8 W   4 W   2 W   Maximum Midband Output Power   THD=1%, 1kHz   560W 900W 1200W   500W 800W 1000W   1800W 2400W ———   72V   850W 1300W 1800W   750W 1200W 1500W   2600W 3600W ———   91V   Rated Output Power   THD< 0.1%, 20Hz ... 20kHz   Maximum Bridged Output Power   THD=1%, 1kHz   Maximum RMS Voltage Swing   THD=1%, 1kHz   Voltage Gain   at 1 kHz   37dB   39dB   Slew Rate   35V/µs   1300W   40V/µs   1850W   Power Consumption   at 1/8 maximum output power @ 4 W   Input Sensitivity   0dBu ( 775mV)   at rated output power @ 4 W, 1 kHz   THD at rated output power,   MBW=80kHz, 1 kHz   < 0.05 %   < 0.01 %   < 0.01 %   <-70 dB   IMD-SMPTE   60 Hz, 7 kHz   DIM30   3.15kHz, 15 kHz   Crosstalk   ref. 1kHz, at rated output power   Frequency Response   -1dB, ref. 1 kHz   13Hz ... 40kHz   10Hz ... 48kHz   20kW   Power Bandwith   THD=1%, ref. 1kHz, half power @ 4 W   Input Impedance   20Hz ... 20 kHz, balanced   Damping Factor   at 100Hz / 1kHz   >400 / >300   Signal to Noise Ratio   A-weighted   105dB   Power Requirements   Protection   230V, 50Hz ... 60Hz   Audio limiters, High temperature, DC, HF, Back-EMF,   Peak current limiters, Inrush current limiters, Turn-on delay   Front-to-Rear, 4-stage-fans   Cooling   Safety Class   I Dimensions (W x H x D), mm   Weight   483 x 132.5 x 385.5   27kg   29kg   Retrofitting kit   Input Transformers   NRS 90176   13   Download from Www.Somanuals.com. All Manuals Search And Download.   BLOCK DIAGRAM   20   Download from Www.Somanuals.com. All Manuals Search And Download.   ABMESSUNGEN/DIMENSIONS   Abmessungen/Dimensions (in mm)   21   Download from Www.Somanuals.com. All Manuals Search And Download.   |