Elation Professional Boating Equipment E Spot LED User Manual |
E Spot Led™
Elation Professional
6122 S Eastern Ave
Los Angeles, Ca 90040
Rev. 3/11/2010 – visage
Version 1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
CONTENTS
1. General Information……………………………………………………………………… 4
a. Introduction………………………………………………………………………. 4
b. Unpacking………………………………………………………..…………..….. 4
c. Customer Support…………………………………………….………………… 4
d. Warranty Registration……………………………………………………..……. 5
2. Safety Instructions………………………………………………………........…………. 6
3. Features……………………………………………………………………………………7
4. General Guidelines………………………………………………………………………. 8
5. Fixture Overview…………………………………………………………………………. 9
6. Mounting and Installation………………………………………………………….……..12
a. Mounting Positions……………………………………………………………… 12
b. Mounting Points…………………………………………………………………. 13
c. Securing………………………………………………………………………….. 14
7. Understanding DMX……………………………………………………………………... 15
a. DMX Cable Requirements……..………………………………………………. 15
b. DMX Terminator………………………………………………………………….17
c. 3-Pin to 5-Pin Conversion……………………………………………………….17
8. Fixture Menu……………………………………………………………………………… 19
a. Menu functions………………………………………………………………….. 21
9. DMX Addressing..…………………………………………………………….. ………….29
10. DMX Channel Traits…...….…………………………………………………………….. 38
a. DMX Channel Values…………………………………………………………… 39
11. Error Codes………………………………………………………………………………. 41
12. Cleaning and Maintenance………………………………………………………………42
13. Photometric Data………………………………………………………………………….43
14. Gobos
15. Dimensional Drawings………………………………………………….……………….. 45
16. Circuit Schematic………...……………………………………………………………….46
17. Technical Specifications…………………………………………...………….………… 49
©Elation Professional, Los Angeles Ca.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
1. GENERAL INFORMATION
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! The E Spot Led,™ has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please read and
understand the instructions in this manual carefully and thoroughly before attempting to
operate this unit. These instructions contain important information regarding safety during
use and maintenance.
UNPACKING: Thank you for purchasing the E Spot Led™ by Elation Professional®. Every E
Spot Led™ has been thoroughly tested and has been shipped in perfect operating condition.
Carefully check the shipping carton for damage that may have occurred during shipping. If
the carton appears to be damaged, carefully inspect your unit for damage and be sure all
accessories necessary to operate the unit have arrived intact. In the event damage has been
found or parts are missing, please contact our customer support team for further assistance.
Please do not return this unit to your dealer without first contacting customer support at the
number listed below.
Inside the box you should find: the E Spot, a DMX cable, a safety cable, two omega clamps
and this manual. Please contact customer support at the number listed below if any items
are missing.
During initial fixture start-up, the fixture may omit some light smoke or release a
slight burning smell. This is a normal process and should decrease gradually.
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide
set up help and to answer any question should you encounter problems during your set up
comments or suggestions. For service related issue please contact Elation Professional®.
Service Hours are Monday through Friday 8:00 a.m. to 5:00 p.m. Pacific Standard Time.
Voice:
Fax:
(323) 582-3322
(323) 832-9142
E-mail:
Forum:
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to
©Elation Professional, Los Angeles Ca.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself, doing so will void your manufactures warranty.
Please do not discard the shipping carton in the trash. Please save for return shipping in the
event service is ever needed or recycle the container whenever possible.
WARRANTY REGISTRATION: The E Spot Led™ carries a two year (730 days) limited
warranty. Please fill out the enclosed warranty card to validate your purchase. All returned
service items whether under warranty or not, must be freight pre-paid and accompany a
return authorization (R.A.) number. The R.A. number must be clearly written on the outside
of the return package. A brief description of the problem as well as the R.A. number must
also be written down on a piece of paper and included in the shipping container. If the unit is
under warranty, you must provide a copy of your proof of purchase invoice. Items returned
without a R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting customer
support at (323) 582-3322.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the light
source at all times.
Never open this fixture while in use!
This device falls under protection-class 1. Therefore it is essential that the device be
grounded properly.
All electrical connections must be performed by qualified personal.
Be sure the available voltage matches the voltage requirements of the unit.
Be sure the power cord is never crimped or damaged. If the power cord is damaged, replace
it immediately with a new one of similar power rating.
Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of
the cord.
©Elation Professional, Los Angeles Ca.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
2. SAFETY INSTRUCTIONS
The E Spot Led™ is an extremely sophisticated piece of
electronic equipment. To guarantee a trouble free operation, it is
important to follow the guidelines in this manual. Elation will not
accept responsibility for damages resulting from the misuse of
this fixture due to the disregard of the information printed in this
manual.
1. Always be sure that the fan and the air inlets remain clean and are never blocked.
Allow about 6” (15cm) between this fixture and other devices or a wall to allow for
proper cooling.
2. Never touch the fixture during normal operation. This can cause severe personnel
injuries and/or damage to the fixture.
3. Be sure to unplug the E Spot Led™ from the power outlet before performing any
service or cleaning related issues.
4. Never look directly into the light source. You risk injury to your retina, which may
induce blindness.
5. For safe operation, follow the Installation guide described in chapter two of this
manual. Operating the E Spot Led™ without suited safety aids such as safety
cables or clamps can increase the risk of damage and/or personal injury.
6. When mounting this fixture, use only the original rigging parts included with this
fixture. Any structural modification will void the original manufactures warranty and
may increase the risk of damage and/or personal injury.
7. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture.
8. Do not attempt to operate this fixture if the power cord has become damaged or
frayed.
9. Installation should only be performed by qualified and certified personal.
Important Notice: Damages resulting from the disregard of safety and general user
instructions found in this user manual are not subject to any warranty claims.
©Elation Professional, Los Angeles Ca.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
3. FEATURES
• Pan 540° or 630˚ (User selectable) / Tilt 270°
• 15˚ Beam Angle
• Low Power Consumption
• 60 WATT White LED Source (Over 2,200 lumens from a single chip)
• 60,000 hours rated LED life
• Color Wheel: 8 colors plus white, with rainbow effect
• Rotating gobo wheel with 7 rotating gobos plus open, all gobos can be easily
replaceable and gobo indexing
• Prism and Prism Rotation, with 16 prism macros (Indexable)
• Flicker-free operation for television and film
• 3 operation mode: DMX controlled, stand alone or sound activated
• Strobe effect: 0~18 flashes per second or random strobe
• 0%~100% Dimming (two dimming options; linear & standard)
• Electronic menu display
• Control board with full LCD character display and foil-keyboard
• RDMX (Remote DMX addressing from any DMX console)
• Auto test for all functions
• Automatic Pan/Tilt Correction
• USITT DMX-512 Complaint (3-pin and 5-pin DMX Connections)
• Value of each DMX-channel can be displayed
• Minimal heat emission
• Maintenance free operation
• Preprogrammed colored macros
• Electronic power supply (100v~240V 50/60Hz)
• 8 built-in programs accessed via DMX-controller or manually
• Built-in DMX recorder - via the control board or external controller, up to 64 scenes
can be saved and then can be run in Stand Alone or sound activated.
©Elation Professional, Los Angeles Ca.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
4. GENERAL GUIDELINES
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in
theatres, etc. Do not attempt operation or installation without a proper knowledge on how to
do so.
This fixture was designed for indoor use only.
Consistent operational breaks may ensure that the fixture will function properly for many
years to come.
Do not shake the fixture around. Avoid brute force when installing or operating the device.
While choosing an installation location, please be sure that the fixture will not be exposed to
extreme heat, moisture or dust. The minimum distance between the fixture and a wall or flat
surface should be at least 0.5 meter (about 1.5ft).
Always install the fixture with an appropriate safety cable. When installing the fixture in a
suspended environment always be sure to use mounting hardware no less than M10 x 25
mm, also be sure the hardware is insert in the pre-arranged screw holes in the base of the
fixture.
When using the quick release “Omega” cam-lock system, be sure the four quick lock
fasteners are locked in the quick lock holes correctly.
Do not attempt to operate this fixture until you have familiarized yourself with its functions.
Do not permit operation by persons not qualified for operating this type of theatrical fixture;
most damages are the result of operations by nonprofessionals.
Please use the original packaging to transport the fixture in for service.
©Elation Professional, Los Angeles Ca.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
5. FIXTURE OVERVIEW
1. LED Assembly
2. LCD Menu Display
3. Mode/Esc Button
4. Up Button
5. Down Button
6. Enter Button
7. Microphone
8. Carrying Handle
9. 3-Pin DMX Output
10. 3-Pin DMX Input
11. 5-Pin DMX Output
12. 5-Pin DMX Input
13. Power Switch
15. Fuse Holder
16. Power Cord
©Elation Professional, Los Angeles Ca.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
1. LED–Extremely high optical LED output, Over 2,200 lumens from a sin-gle chip (White)
2. LED Menu Display - 4-segment menu display. Used to display the DMX address as
well as all other menu functions.
3. Mode/Esc Button - This button is used to access the menu functions.
4. Up Button – The up button is used to toggle forward through the menu functions and
settings.
5. Down Button – The down button is used to toggle backwards through the menu
functions and settings.
6. Enter Button – The enter button is used to enter in to a certain menu function or to lock
a function into memory.
7. Microphone – Internal microphone is used to trigger built-in scenes to sound.
8. Carrying Handle – Please use this intergraded handled to move the fixture form
location to location. Never carry the fixture by the head.
9. 3-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next
fixture in the DMX chain via a female, 3-pin XLR jack.
10. 3-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 3-pin
XLR jack.
11. 5-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next
fixture in the DMX chain via a female, 3-pin XLR jack.
12. 5-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 5-pin
XLR jack.
©Elation Professional, Los Angeles Ca.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
13. Power Switch – Controls main power to the unit.
14. Fuse Holder Assembly – This assembly houses the 4amp GMA safety fuse. Always
replace the fuse with an exact match unless otherwise specified by an authorized Elation
Service Technician. Using a fuse other than that specified could seriously damage the
unit and will void your manufactures warranty.
15. Power Cord – Plug into an appropriate power outlet to provide main power to the
fixture.
©Elation Professional, Los Angeles Ca.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
6. MOUNTING AND INSTALLATION
Cautions:
For added protection mount the fixtures in areas outside walking paths, seating areas, or in
areas were the fixture might be reached by unauthorized personal.
Before mounting the fixture to any surface, make sure that the installation area can hold a
minimum point load of 10 times the device’s weight.
Fixture installation must always be secured with a secondary safety attachment, such as an
appropriate safety cable.
Never stand directly below the device when mounting, removing, or servicing the fixture.
Caution!
When install the fixture be sure there is no highly inflammable
material within a distance of .5m (1.5 feet)
Mounting
The E Spot Led™ is fully operational in two different mounting positions, hanging
upside-down from a ceiling, or set on a flat level surface (see illustration on the next page).
Never mount the fixture on its’ side in any type of installation. Be sure this fixture is kept at
least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). Always use and
install the supplied safety cable as a safety measure to prevent accidental damage and/or
injury in the event the clamp fails.
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217
for proper installation in Europe To ensure proper installation, only
qualified staff should attempt installation.
©Elation Professional, Los Angeles Ca.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
Mounting points
Overhead mounting requires extensive experience, including amongst others calculating
working load limits, a fine knowledge of the installation material being used, and periodic
safety inspection of all installation material and the fixture. If you lack these qualifications, do
not attempt the installation yourself. Improper installation can result in bodily injury.
CAUTION!
Be sure a qualified electrician performs all electrical
connections.
Be sure to complete all rigging and installation procedures before connecting the main
power cord to the appropriate wall outlet.Clamp Mounting
©Elation Professional, Los Angeles Ca.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
The E Spot Led™ provides a unique mounting bracket assembly that integrates the bottom of
the base, the included “Omega Bracket,” and the safety cable rigging point in one unit (see
the illustration below). When mounting this fixture to truss be sure to secure an appropriately
rated clamp to the included omega bracket using a M10 screw fitted through the center hole
of the “omega bracket”. As an added safety measure be sure to attached at least one
properly rated safety cable to the fixture using the safety cable rigging point integrated in the
base assembly
Securing the E Spot Led™
Regardless of the rigging option you choose for your E Spot Led™ always be sure to secure
your fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable
on the hanging bracket as illustrated above. Be sure to only use the designated rigging point
for the safety cable and never secure a safety cable to a carrying handle.
©Elation Professional, Los Angeles Ca.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
7. UNDERSTANDING DMX
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most
lighting and controller manufactures as a form of communication between intelligent fixtures
and controllers. DMX allows all makes and models of different manufactures to be linked
together and operate from a single controller. This is possible as long as all the fixtures and
the controller are DMX compliant. A DMX controller sends the DMX data instructions to the
fixture allowing the user to control the different aspects of an intelligent light. DMX data is
sent out as serial data that travels from fixture to fixture via data “IN” and data “OUT” XLR
terminals located on the fixtures (most controllers will only have output jacks).
DMX Linking: To ensure proper DMX data transmission, always use proper DMX cables
and a terminator. When using several DMX fixtures try to use the shortest cable path
possible. Never split a DMX line with a “Y” style connector. The order in which the fixtures
are connected in a DMX line does not influence the DMX addressing. For example; a fixture
assigned a DMX address of 1 may be placed anywhere in the DMX chain, at the beginning,
at the end, or anywhere in the middle. The DMX controller knows to send data assigned to
address 1 to that fixture no matter where it is located in the DMX chain. The E Spot Led™
can be controlled via DMX-512 protocol. The E Spot Led™ is a 14-channel DMX fixture. The
DMX address is set electronically using the controls on the LCD menu.
Note: Although microphone and DMX cables may look similar, they are
not constructed of the same material and should never be used in place
of each other.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your
fixture and your DMX controller require a standard 3-pin or 5-pin XLR connector for data
input and data output (the figure on the next page is of a 3-Pin XLR connector). If you are
making your own cables, be sure to use two conductor shielded digital DMX cable rated at
120 ohms; this cable is designed for DMX transmission and may be purchased from your
Elation dealer or at most professional lighting retailers. Your cables should be made with a
male and female XLR connector on either end of the cable. Also, remember that a DMX line
must be daisy chained and cannot be split, unless using an approved DMX splitter such as
©Elation Professional, Los Angeles Ca.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
the Elation Opto Branch 4™ or DMX Branch/4™.
Be sure to follow the above figure when making your own cables. Do not use the ground lug
on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or
allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the
shield could cause a short circuit and erratic behavior.
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the
other side to the male 3-pin XLR input of the moving head (Please refer to the diagram
below.). You can chain multiple moving heads together through serial linking. The cable that
should be used is two conductor, shielded DMX cable with XLR input and output connectors.
Always be sure daisy chain your in and out data connections, never split or “Y” your DMX
connections unless you are using an approved DMX splitter such as the Elation Opto Branch
4™ or DMX Branch/4™.
©Elation Professional, Los Angeles Ca.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
DMX-512 connection with DMX terminator
A DMX terminator should be used in all DMX lines especially in longer runs. The use of a
terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt
resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy
chain to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease
the possibilities of erratic behavior.
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must
be used, these adaptors are readily available at most electric stores. The following chart
details a proper cable conversion.
Fixture DMX addressing;
All fixtures should be given a DMX starting address when using a DMX controller, so the
correct fixture responds to the correct control signal. This digital starting address is the
channel number from which the fixture starts to “listen” to the digital control information sent
©Elation Professional, Los Angeles Ca.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
out from the DMX controller. The allocation of this starting DMX address is achieved by
setting the correct DMX address on the digital display located on the base of the fixture.
You can set the same starting address for all fixtures or a group of fixtures, or set different
address for each individual fixture. Be advised that setting all you fixtures to the same DMX
address will subsequently control all fixtures in the same fashion, in other words, changing
the settings of one channel will affect all the fixtures simultaneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the
channel number you have set, based on the quantity of control channels (DMX channels) of
each fixture. That means changing the settings of one channel will only affect the selected
fixture.
In the case of the E Spot Led™, which is a 14 channel fixture, you should set the starting
DMX address of the first unit to 1, the second unit to 15 (14 + 1), the third unit to 29 (14 + 15),
and so on.
Note: During start-up the E Spot Led™ will automatically detect whether a DMX data signal
is being received or not. If DMX data signal is being received, the display will show
"Addr=XXX" (XXX representing the actual DMX address). If the fixture is not receiving a
DMX signal the display will flash. If your fixture is connected to a DMX controller and the
display is flashing (not receiving a DMX signal), please check the following:
-
The 3-PIN or 5-PIN XLR input plug (cable with DMX signal from controller) is not
connected or is not inserted completely into the DMX input jack of the fixture.
The DMX controller is switched off or defective.
-
-
-
The DMX cable or connector is defective.
A DMX terminator has been inserted into the last fixture in your DMX chain.
©Elation Professional, Los Angeles Ca.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
8. FIXTURE MENU
On-Board System Menu: The E Spot Led™ comes with an easy to navigate system menu.
This next section will detail the functions of each command in the system menu.
LCD Control Panel: The control panel located on the base of the fixture allows you to
access the main menu and make all necessary adjustments to the E Spot Led™. During
normal operation, tapping the “Mode/Esc” key once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and access the
sub-menus with the Up and Down buttons. Once you reach a field that requires adjusting,
tap the ENTER button to activate that field and use the UP and Down button to adjust the
field. Tapping the Enter button once more will confirm your setting. Once a setting is saved
the display will briefly readout OK to confirm a new setting has been made and locked into
memory. You may exit the main menu at any time without making any adjustments by
tapping the Mode/Esc button.
MODE/ESC Button - To access the main menu locate the Mode/Esc button on the front of
the unit. Press this button to activate the system menu. Tap the UP button until you reach
the function you wish to change. When you reach the function you wish to change tap the
ENTER button once to select that menu function. When a function is selected use either the
UP or DOWN buttons to change the function. Once your changes are made tap the ENTER
button yet again to lock the change in the system menu. To exit without making any
changes tap the Mode/Esc button.
Default settings shaded.
Indicate the staring DMX address
0
1
ADDR
TEST
AXXX A001
T-01~T-XX
RUN
A001 also is the setting for slave
Automatically test the function
Runs fixture as “master” or “alone” for
auto
MSTR/ALON
Runs fixture as “master” or “alone” for
audio
2
3
PLAY
RESE
AUDI
AUTO
ALL
MSTR/ALON
No DMX Status
Clos/Hold/Auto/Audi
Reset all motors and returns fixture to
home
SCAN
COLR
Reset only motors for pan/tilt
Reset only motors for colors
©Elation Professional, Los Angeles Ca.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
Reset only motors for gobo and
rotation
GOBO
OTHR
Reset other motors
LIFE
CLMP
0000~9999
Displays the total fixture running time
Clear lamp running time
4
TIME
5
6
7
8
9
RPAN
RTLT
FINE
DEGR
MIC
ON/OFF
ON/OFF
ON/OFF
540/630
M-XX M-70
Reverses the pan movements
Reverses the tilt movements
Switch 16 bit/8 bit
Pan degree select
Mic sensitivity
Display the DMX512 value of each
channel
Display turn off after 2mins
This function will reverse the display
180
VALU
D ON
FLIP
D–XX D-00 (DXXX)
ON/OFF
10 DISP
ON/OFF
Change DMX address via external
controller
Lamp optimization
Resets all the fixture functions to
default
RDMX
SPOT
DFSE
ON/OFF
ON/OFF
ON/OFF
Pan/tilt feedback (error correction)
on/off
11 SPEC
FEED
ON/OFF
FANS
VER
AUTO/HIGH/LOW
V1.0~V9.9
Fan’s mode select
Software version
CODE
CH01~CHXX
AUTO
CXXX
XXXX(-128~127)
Srvice code is “C050”
Motor Fix
ADJU
SEPR
STEP
Select program to be edit
IP01~IP08
Set the amount of your
program
Edit the channels of each
scene
Time for each scene
Edit program via controller
Auto Save
S–01 ~S–48
C–01~C–XX
0 1 XX(00~FFH)
XX XX(00~FFH)
T XXX(001~999)
ON/OFF
12 EDIT
SCXX
TIME
CEDT
RE.XX
ON/OFF
REC.
RUN
Program test
Main Menu Functions
1. ADDRESS MENU
- AOO1 - A511 (Value) - This is where you set the fixtures DMX address.
Setting/Changing the DMX Address
After applying power to the E Spot Led™ the LED will display the fixture’s current DMX
address immediately after the reset sequence. If the fixture is not receiving a DMX
signal the display will flash continuously. To set or adjust a DMX address, please follow
the procedure below:
©Elation Professional, Los Angeles Ca.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
1. Switch on the E Spot Led™ and wait for the fixture reset process to finished.
2. Press the Mode/Esc button to access the main menu. Toggle through the menu by
pressing the Up and Down buttons until the display shows A001. Tap the enter
button to make changes to the address, the current three digit address will
immediately begin to flash.
3. While the current three-digit address is flashing, use the Up and Down buttons to
select adjust the address. Lock your new address into the unit’s memory by
pressing the Enter button. After the new address has been successfully stored into
the fixture’s memory the LED will briefly readout PASS.
The DMX address is non-destructible and will remain in the fixture’s memory even when
power to the fixture has been switched off. Memory is backed-up and retained by an internal
power source with a five year shelf life.
2. TEST MENU
- T-01 - T-XX (Test) - Tests the functions of channel. To enter the test menu follow
the procedure below:
1. Access the main menu.
2. Tap the UP button until “TEST” is displayed, press ENTER.
3. The display will read T-01. You can now press the up button and test the different
channels. For example: If you press the up button until “T-05” is displayed, the unit
will test the color channel, changing the color one by one and show the rainbow
effect with different speeds.
4. Press MODE/ENTER or EXIT to exit.
3. PLAY MENU -
RUN
– This feature is used to run the internal preset programs in either a Master/Slave
or a stand-alone operating mode. Follow the procedure below to enter the run menu:
1. Access the main menu.
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.
3. Tap the UP or DOWN button until “RUN” is displayed, press ENTER.
©Elation Professional, Los Angeles Ca.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
4. Tap the UP or DOWN button to select either “Master” or “Alone” and press ENTER.
5. Press MODE/ESC to return to the main menu.
AUDI
- This feature is used to run the internal preset programs in AUDIO mode in either a
Master/Slave or a stand-alone operating mode Follow the procedure below to enter the
audio menu:
1. Access the main menu.
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.
3. Tap the UP or DOWN button until “AUDI” is displayed, press ENTER.
4. Tap the UP or DOWN button to select either “Master” or “Alone” and press ENTER.
5. Press MODE/ESC to return to the main menu.
AUTO
– Runs the unit without any DMX signal in stand-alone mode. Follow the procedure
below to enter the auto menu:
1. Access the main menu.
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.
3. Tap the UP or DOWN button until “AUTO” is displayed, press ENTER.
4. Tap the UP or DOWN button to select “CLOS”, “HOLD,” “AUTO,” or “AUDI” and
press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
This function dictates how the fixture will function if it looses DMX signal during
normal operation. The default function is set to hold, in which the fixture will lock into
the last DMX signal it received and remain in that position until it is turned off or
begins receiving a new DMX signal. If the fixture is turned on without any DMX
signal, the fixture will automatically go in to sound-active mode. Available settings
are: “Close” – Shutter flags will close. “Hold” – Fixture will remain at it’s last settings.
“Auto” – Fixture will go into stand-alone mode, running the built-in program. “Music”
– The fixture will go into sound-active mode.
©Elation Professional, Los Angeles Ca.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
4. RESE (RESET) MENU -
ALL - Resets all the motors in the unit.
SCAN - Resets the Pan and Tilt motors.
COLR (Color) - Resets the color motors.
GOBO - Resets the gobo motors.
SHTR - Resets the shutter motors.
OTHR - Reset all other motors
ALL
- When you activate this reset function, the fixture will begin to reset all motors.
1. Access the main menu.
2. Tap the UP button until “RESE” is displayed, press ENTER.
3. Tap the UP button until “ALL” is displayed, press ENTER.
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the
color motor.
5. Press ENTER to confirm
6. Press MODE/ESC to return to the main menu.
SCAN
- When you activate this reset function, the fixture will only reset the Pan and
Tilt mirror motor.
1. Access the main menu.
2. Tap the UP button until “RESE” is displayed, press ENTER.
3. Tap the UP button until “SCAN” is displayed, then press ENTER to confirm.
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the
color motor. Press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
COLR
- When you activate this reset function, the fixture will only reset the color
©Elation Professional, Los Angeles Ca.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
wheel motor.
1. Access the main menu.
2. Tap the UP button until “RESE” is displayed, press ENTER.
3. Tap the UP button until “COLR” is displayed, then press ENTER to confirm.
4. The display will show “ON/OFF”. Press the UP button to select“ON”to reset the
color motor. Press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
GOBO
- When you activate this reset function, the fixture will only reset the gobo
wheel motor.
1. Access the main menu.
2. Tap the UP button until “RESE” is displayed, press ENTER.
3. Tap the UP button until “GOBO” is displayed, press ENTER to confirm and begin
the reset process.
4. Press MODE/ESC to return to the main menu.
OTHR
- When you activate this reset function, the fixture will only reset any motor not
specified in the other reset commands previously listed.
1. Access the main menu.
2. Tap the UP button until “RESE” is displayed, press ENTER.
3. Tap the UP button until “OTHR” is displayed, then press ENTER to confirm.
4. The display will show “ON/OFF”. Press the UP button to select“ON”to reset the
color motor. Press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
5. TIME MENU -
LIFE - Displays the fixtures total running time.
©Elation Professional, Los Angeles Ca.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
CLMP - Clears the lamp running time.
LIFE
- With this function you can display the total running time of the fixture.
1. Access the main menu.
2. Tap the UP button until ”TIME” is displayed, press ENTER.
3. Tap the UP button until “LIFE” is displayed, press ENTER.
4. Press MODE/ESC to return to the main menu.
CLMP
- With this function you can clear the running time of the lamp. Note: Please
clear the lamp time every time you replace the lamp.
1. Access the main menu.
2. Tap the UP button until “TIME” is displayed, press ENTER.
3. Tap the UP button until “CLMP” is displayed, press ENTER.
4. Press MODE/ ENTER, the display will show “ON/OFF”.
5. Press the UP button to select “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
6. RPAN MENU
- This menu function will reverse the mirror PAN movements.
1. Access the main menu.
2. Tap the UP button until “RPAN” is displayed, press ENTER.
3. The display will show “ON/OFF”.
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate
this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
7. RTLT MENU
©Elation Professional, Los Angeles Ca.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
- This menu function will reverse the mirror TILT movements.
1. Access the main menu.
2. Tap the UP button until “RTLT” is displayed, press ENTER.
3. The display will show “ON/OFF”.
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate
this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
8. FINE MENU
- This menu item switches between 16 bit (fine) and 8 bit (coarse) modes. When
this function is turned on the fixture will operate in 16 bit (fine) mode. When functioning in 16
bit mode the fixture will use 16 DMX channels, when the 16bit function is turned off the
fixture will use 14 DMX channels. To access the Fine menu follow the procedure below:
1. Access the main menu.
2. Tap the UP button until “FINE” is displayed, press ENTER.
3. The display will show “ON/OFF”.
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate
this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
9. DEGR MENU -
- This menu function will toggle between the 630°and 540°for pan movement
When this function is turned on, the fixture will operate with a pan movement of 540˚.
1. Access the main menu.
2. Tap the UP button until “DEGR” is displayed, press ENTER.
3. The display will display “630/540”.
4. Press the UP or DOWN button to select 630˚ or 540˚ for the pan movement angle,
the default is 540˚
5. Press ENTER to confirm.
©Elation Professional, Los Angeles Ca.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
6. Press MODE/ESC to return to the main menu.
10. MIC MENU
- This function allows for electronic control of the internal microphone’s sound
sensitivity.
1. Access the main menu.
2. Tap the UP button until “MIC” is displayed and press ENTER.
3. The display will show “M-XX” (Where XX represents a value between 00 & 99).
4. Use the UP and DOWN button to adjust the mic sensitivity, 99 being the highest.
5. Press ENTER to confirm and lock your new setting in place.
6. Press MODE/ESC to return to the main menu.
11. DISPLAY MENU
- This menu function will control the various on-board display features.
VALU – This function will display the DMX value of each channel as it is
adjusted through the use of a DMX console.
1. Access the main menu.
2. Tap the UP button until “DISP” is displayed.
3. Press ENTER, the display will show “VALU”.
4. Press ENTER, once again “d-00” will be displayed.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
D ON – This function will turn the display off after the has gone two seconds
without any menu activity.
1. Access the main menu.
2. Tap the UP button until “DISP” is displayed.
3. Press ENTER, the display will show “VALU”.
4. Tap the UP button until ”D-ON” is displayed and tap the ENTER button.
Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this
function. When set “OFF”, this function will turn the display off after the display has gone
©Elation Professional, Los Angeles Ca.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
two seconds without any menu activity.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
FLIP – This function will reverse the display readout buy 180˚.
1. Access the main menu.
2. Tap the UP button until “DISP” is displayed.
3. Press ENTER, the display will show “VALU”.
4. Tap the UP button until ”FLIP” is displayed and tap the ENTER button.
5. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate
this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
13. SPEC MENU – This menu option access all the special functions listed below.
RDMX - Allows DMX address to be changed via and external DMX controller.
SPOT - This provides a spot beam for better lamp optimization.
DFSE (Default) - Resets the unit to all default settings.
FEED - This function turn the DMX correction feature “ON” (default) or “OFF.”
FANS- Changes the functionality of the built-in fans.
VER (Version) - Displays the software version.
ADJU – Calibration functions
RDMX
– This function allows the DMX address to remotely be adjusted from a DMX
console. This setting requires special settings for both the controller and the fixture.
RDMX is on by default. Follow the procedure listed below to access the RDMX
functions:
Fixture Settings:
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “RDMX” is displayed, press ENTER.
©Elation Professional, Los Angeles Ca.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
Controller Settings:
1. Set the DMX value of channel 1 to a value of 7.
2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7"
you can adjust the starting address between 1 and 255. When set to "8" you can
adjust the starting address between 256 and 511.
3. Use channel 3 to set your desired DMX starting address. For example: If you
want to set the starting address to 57, set channel 1 to a value of “7,” set channel
2 to a value of “7” and use channel 3 to set your address to 57 by selecting a
channel value of 57. Example 2: If you want to set the starting address to 420, set
channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164"
(256+164=420).
4. Wait for approximately 20 seconds for the unit to complete the address
reset function.
SPOT
– This function allows you to optimize the lamp without the use of an external
DMX controller. In this mode, the device will not react to any control signal.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “DFSE” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
©Elation Professional, Los Angeles Ca.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
DFSE
- With this function you can restore the factory default settings of the fixture. All
settings will be set back to the default values. Any edited scenes will be lost. When
restoring the factory settings the unit must be set to the address that the unit was in
when you started editing. When you confirm this function, the fixture will begin to
reload the original factory settings.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “DFSE” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
FEED
- Use this function to activate the pan/tilt error correction.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “FEED” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
FANS
- This function is used to change the functionality of the internal cooling fans.
Follow the procedure below to access the fan menu:
1. Access the main menu.
2. Tap the UP or DOWN button until “SPEC” is displayed, press ENTER.
©Elation Professional, Los Angeles Ca.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
3. Tap the UP or DOWN button until “FANS” is displayed, press ENTER.
4. The display will show “HIGH/AUTO”.
5. Press UP or DOWN button to select “HIGH” or “AUTO”.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
VER
- Use this function to display the Software version of the unit.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “VER” is displayed, press ENTER.
4. The display will show “V-1.0,” the display may also show, “V-2.0,” “V-9.9” etc.
5. Press ENTER or MODE/ESC to exit.
ADJU
- This function is used to calibrate the various internal motors in the event the
internal homing mechanism become slightly out of adjustment. This function is protected
with a password to prevent unauthorized personal from tampering with the fixture. To
enter the calibration menu follow the steps below:
1. Access the main menu.
2. Tap the UP or DOWN buttons until “ADJU” is displayed, then press ENTER.
3. Tap the UP or DOWN buttons until “CODE” is displayed, then press ENTER.
4. The display will show “CXXX”, were as XXX represents the calibration password.
The calibration password is “C050.” Use the UP or DOWN buttons to enter the
proper password.
5. Once the proper password is entered the display will read “CHXX”, were as “XX”
represents the fixture channel number, in the case of the E Spot Led™ 1 ~ 16.
6. Select the desired channel to be calibrated by pressing the UP or DOWN
buttons and then ENTER to confirm.
7. The display will then read “xxxx”, were “xxxx” stands for the calibrate values.
8. Adjust the desired calibration value between –128 and 127 by pressing the UP
and DOWN. As you scroll up and down through the calibration values you will
notice slight changes in the wheel or motor you are attempting to calibrate.
©Elation Professional, Los Angeles Ca.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
9. Once you reach your desired calibration press ENTER to confirm and lock in
your calibration.
14. EDIT MENU
- This menu item allows you to write a program into the fixture’s internal memory
(EEPROM) via the control panel or via an external DMX controller.
SEPR- Select program to be edit.
STEP (S-01 - S-48) - These are the steps slots that you write your programs into. There
are at total of 48 steps.
STXX (SC01 – SC48) - These are the scenes that are stored in your program. There are a
total of 48 scenes. C-01 - C-11 (Channel 1 - Channel 11) – Represents the total fixture
channels for each scene that can be edited.
TIME (Time) - Running time of the entire program.
CEDT - Edit program using a external controller.
REC – Auto save function.
RUN – Program test mode.
REC
- Records scenes automatically from any external DMX controller and stores them
inside the fixtures built-in memory. These scenes can then be recalled without the use of
an external controller.
1. Access the main menu.
2. Tap the UP or DOWN buttons until “EDIT” is displayed, then press ENTER.
3. Tap the UP or DOWN buttons until “REC” is displayed, then press ENTER.
4. After entering the REC function the display will read “RE.XX,” where as “XX”
represents the scene number in the internal memory to which the scene will be
stored.
5. Press the UP or DOWN buttons to select the desired scene number.
6. When you reach the scene number you wish to store the scene to, press ENTER
to confirm and lock the scene into the fixture’s memory.
7. Press MODE/ESC to return to the main menu.
©Elation Professional, Los Angeles Ca.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
SEPR
- With this function you can Select program to be edit.
1. Access the main menu.
2. Tap the UP button until “EDIT” is displayed, press ENTER.
3. Tap the UP button until “SEPR” is displayed, press ENTER.
4. The display shows “IP01,” this indicates the first step of your program. You can
call up to “IP08” scenes in “AUTO.” For example.
5. Press ENTER to save and MODE/ESC to exit.
STEP
- With this function you can program the number of steps in your individual
Program.
1. Access the main menu.
2. Tap the UP button until “EDIT” is displayed, press ENTER.
3. Tap the UP button until “STEP” is displayed, press ENTER.
4. The display shows “S-01,” this indicates the first step of your program. You can
call up to 48 scenes in “Run.” For example; if “S-05” is displayed, it means that
the scene will “RUN” the first 5 scenes you saved in “Edit.”
5. Press ENTER to save and MODE/ESC to exit.
SC01
- This function allows you to choose the total number of scenes in your internal
program.
1. Access the main menu.
2. Tap the UP button until “EDIT” is displayed, press ENTER.
3. Tap the UP button until “SC01” is displayed.
4. The display indicates “SC01,” this stands for the first scene of your program.
You may recall up to 48 scenes. For example, if you choose “SC05,” and then
select the “Run” function, the first 5 scenes you saved in “Edit” mode will run.
5. Press ENTER to save and MODE/ESC to exit.
©Elation Professional, Los Angeles Ca.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
Editing procedure 1: Using the control board only.
1. Access the main menu.
2. Tap the UP button until “EDIT” is displayed and press ENTER.
3. The display will show “SC-01”, this stands for the scene number. For example,
“SC-01” is displayed, it means you will be editing scene 1, press ENTER. You
can change the scene number by tapping the UP button.
4. Press ENTER, the display will show “C-01,” this represents the channel number.
If “C-01” is displayed, you will be editing the fixture’s channel 1 value of the
selected scene, press ENTER. You can change the channel number by tapping
the UP button.
5. The display will show the DMX value for the channel that is being edited. It will be
displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX
value is “XX.”
6. Adjust the DMX value by tapping the UP button, until you get the expected effect
for this channel.
7. Press ENTER to enter the editing of the other channels of the scene.
8. Repeat steps 5-8, until you finish setting all the DMX values for all the channels
of this scene, each scene can have 16 channels maximum.
9. Once all the channels are completed, the display will begin to flash “TIME,” this
indicates the time needed to run this scene.
10.Press ENTER to edit the time needed, the display shows “TXXX”, “XXX”
represents the time needed to run this scene. For example, “T002” means
scene 1 needs 0.4 seconds to run,“T-15”means this scene needs 3.0 seconds
to run. Note: “XX” is always 0.2 seconds not one second.
11.Adjust the time needed by tapping the UP button.
12.Press ENTER to save the settings for the scene you are editing, the display will
change to the next scene automatically.
13.Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes
maximum.
14.Press MODE/ESC to exit and save your edited scene into the fixtures internal
©Elation Professional, Los Angeles Ca.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
memory. The number of steps can be defined under “EDIT” and the scenes can
be called up under “Run.” To run the scenes see page 30.
Editing procedure 2: Using an external controller.
1. Call up the first scene in your controller now.
2. Select “SC01” by pressing the UP or DOWN buttons.
3. Press MODE/ESC, the display shows “SC01”.
4. Press MODE/ESC, the display shows “C-01”.
5. Select "CEDT" by pressing the UP or DOWN buttons.
6. Press MODE/ESC, the display shows "OFF".
7. Press UP, the display will read "ON".
8. Press MODE/ESC, the display shows "SC02". You successfully downloaded
the first scene.
9. Adjust the Step-time as described above.
10. Call up the second scene in your controller now.
11. Repeat steps 5-11 until all desired scenes are downloaded.
12. Press MODE/ESC to exit. The number of steps can be defined under “STEP”
and the scenes can be called up under “RUN.”
RUN
- This function allows you to “RUN” the user-installed program. You can set the
number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit.
1. Access the main menu.
2. Tap the UP button until “EDIT” is displayed, press ENTER.
3. Tap the UP button until “RUN” is displayed, press ENTER.
4. The display will show “ON/OFF”.
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press MODE/ESC to return to the main menu.
©Elation Professional, Los Angeles Ca.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
9. DMX ADDRESSING
Setting the DMX address - After the fixture is turned “ON” it will immediately complete a
reset process that test all the fixture’s functions. When the reset process concludes the LCD
will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the
display will flash continuously. To set or adjust a DMX address, please follow the procedure
below:
1. Toggle through the menu by pressing the Up and Down buttons until the display
reads “Addr=XXX.” Tap the enter button to make changes to the address.
2. While the display is flashing use the “UP” and “DOWN” buttons to select a new
address. Once the new address has been selected, lock the new address into
the fixture’s memory by pressing the “ENTER” button.
The DMX address is non-volatile and will remain in the fixture’s memory even when the
power to the unit is switched off. Memory is backed-up and retain by an internal power
source that should last about five years
Remote DMX addressing (RDMX) / Address Via DMX- This function allows the DMX
address to be changed remotely from a DMX console. This setting requires special settings
for both the controller and the fixture. This function may be turned on and off, and is “ON” be
default. Follow the procedure listed below to access the RDMX functions:
Fixture Settings:
8. Access the main menu and use the UP or DOWN to get to the
“Personality” menu, then press ENTER
9. Once in the “Personalities” menu, tap the UP or Down to get to the
“Status Settings “ menu, press ENTER.
10.Once in the “Status Settings” tap the UP or Down to get to the “Address via
DMX” function and press ENTER.
11.“Address via DMX” is the function that turns the RDMX function on and off.
Press ENTER and be sure the function is turned on.
12.Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
©Elation Professional, Los Angeles Ca.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
13.Press ENTER to confirm.
14.Press MODE/ESC to return to the main menu.
Controller Settings:
6. Set the DMX value of channel 1 to a value of 7.
7. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is
set to "7" you can adjust the starting address between 1 and 255. When
set to "8" you can adjust the starting address between 256 and 511.
8. Use channel 3 to set your desired DMX starting address. For example: If
you want to set the starting address to 57, set channel 1 to a value of “7,”
set channel 2 to a value of “7” and use channel 3 to set your address to
57 by selecting a channel value of 57. Example 2: If you want to set the
starting address to 420, set channel 1 to a value of “7,” channel 2 to "8"
and channel 3 to "164" (256+164=420).
9. Wait for approximately 20 seconds for the unit to complete the
address reset function.
©Elation Professional, Los Angeles Ca.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
10. DMX CHANNEL TRAITS:
The chart below details the channel layout for 14 DMX channels (default).
In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the fixture
into a 12-channel DMX fixture.
CHANNEL 1: Pan Movement (max. 540° or 630˚ User Selectable)
CHANNEL 2: 16bit Pan Movement (pan fine)
CHANNEL 3: Tilt Movement (max. 265°)
CHANNEL 4: 16bit Tilt Movement (tilt fine)
CHANNEL 5: Color Wheel
CHANNEL 6: Gobos rotating
CHANNEL 7: Rotating gobo
CHANNEL 8: Prism rotating
CHANNEL 9: Rotating prism
CHANNEL 10: Focus
CHANNEL 11: Strobe (0-13Hz), Shutter close/open function + random strobe
CHANNEL 12: Dimmer (Intensity) Control
CHANNEL 13: Speed Control (Pan/Tilt movement, blackout selection)
CHANNEL 14: Special (program control + lamp on, motor reset, lamp switch off)
©Elation Professional, Los Angeles Ca.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
DMX channel function and values:
DMX channel functions and their values (14 DMX channels):
Mode/Channel
Value
Function
St
Ba
Ex
PAN Movement 8bit
Pan Movement By 540/630
Pan Fine 16bit
Fine control of Pan movement
TILT Movement 8bit
Tilt Movement By 270
Tilt Fine 16bit
Fine control of Tilt movement
Color Wheel
1
2
3
4
1
0-255
0-255
0-255
0-255
2
0-14
15-29
Open / white
Color1
30-44
Color2
45-59
Color3
60-74
Color4
5
3
75-89
Color5
90-104
105-119
120-127
128-189
190-193
194-255
Color6
Color7
Color8
Forwards rainbow effect from fast to slow
No rotation
Backwards rainbow effect from slow to fast
Rotating gobos, cont. rotation
Open
6
4
0-9
10-19
Rotating gobo 1
20-29
Rotating gobo 2
30-39
Rotating gobo 3
40-49
Rotating gobo 4
50-59
Rotating gobo 5
60-69
Rotating gobo 6
70-79
Rotating gobo 7
80-95
Rotating gobo 1 shake
Rotating gobo 2 shake
Rotating gobo 3 shake
Rotating gobo 4 shake
Rotating gobo 5 shake
96-111
112-127
128-143
144-159
©Elation Professional, Los Angeles Ca.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
160-175
176-191
192-255
Rotating gobo 6 shake
Rotating gobo 7 shake
Rotating gobo wheel cont. rotation slow to fast
Rotating gobo index, rotating gobo rotation
Gobo indexing
0-127
7
5
128-189
190-193
194-255
Forwards gobo rotation from fast to slow
No rotation
Backwards gobo rotation from slow to fast
Rotating prism, Prism / Gobo macros:
0-31
32-63
Open
3 facet prism
Infinite (Trapezoid) prism
5 facet prism
Macro 1
64-95
96-127
128-135
136-143
144-151
152-159
160-167
168-175
176-183
184-191
192-199
200-207
208-215
216-223
224-231
232-239
240-247
248-255
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
8
6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
Macro 13
Macro 14
Macro 15
Macro 16
Rotating prism index, rotating prism rotation:
Prism indexing
0-127
128-189
190-193
194-255
Forwards prism rotation from fast to slow
No rotation
Backwards prism rotation from slow to fast
Focus:
Continuous adjustment from far to near
Shutter, strobe
9
7
10
11
8
9
0-255
0-31
Shutter closed
©Elation Professional, Los Angeles Ca.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
32-63
64-95
No function (shutter open)
Strobe effect slow to fast
No function (shutter open)
Pulse-effect in sequences
No function (shutter open)
Random strobe effect slow to fast
No function (shutter open)
Dimmer (intensity)
Intensity 0 to 100%
96-127
128-159
160-191
192-223
224-255
12
13
10
11
0-255
Speed pan/tilt movement
Max to min speed
Movements trigger blackout
Wheel changes trigger blackout
No function
0-225
226-235
236-245
246-255
Reset, internal programs
Color change normal
Color change to any position
No function
0-19
20-39
40-59
60-79
No function
80-84
All motors reset
85-87
Scan motors reset
88-90
91-93
Colors motors reset
Gobo motors reset
14
12
94-96
No function
97-99
Other motor reset
100-119
120-139
140-159
160-179
180-199
200-219
220-239
240-255
Internal program 1
Internal program 2
Internal program 3
Internal program 4
Internal program 5
Internal program 6
Internal program 7
Auto program by music
©Elation Professional, Los Angeles Ca.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
11.ERROR CODES:
When power is applied, the unit will automatically enter a “reset/test” mode. This mode
brings all the internal motors to a home position. If there is an internal problem with one or
more of the motors an error code will flash in the display in the form of “XXer” were as XX will
represent a function number. For example, when the display shows “0Er,” it means there is
some type of error with the Pan motor. If there are multiple errors during the start-up process
they will all flash in the display. For example: if the fixtures has errors on channel 1, channel
2, and channel 5 all at the same time, you will see the error message “01Er”, “02Er,”
and ”05Er” flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a
second reset signal and try to realign all the motors and correct the errors, if the error persist
after a second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the fixture will make the
following determinations: 1) 3 or more errors - The fixture cannot function properly with three
or more errors therefore the fixture will place itself in a stand-by mode until subsequent
repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors, therefore
most other functions will work properly. The fixture will attempt to operate normally until the
errors can be correct by a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
PAN Error: The yoke is not located in the default position after start-up or after a reset
command. This message will appear after a fixture reset if the pan’s magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective
motor or a defective motor IC drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
TILT Error: This message will appear after a fixture reset if the tilt’s magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective
motor or a defective motor IC drive on the main PCB). This error may also be displayed if the
head was blocked during a reset function.
©Elation Professional, Los Angeles Ca.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command. This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Prism-wheel error
This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Prism wheel is not located in the default position after
the reset.
Focus-error
This message will appear after the reset of the fixture and if the magnetic indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The focus motor is not located in the default position after
the reset.
©Elation Professional, Los Angeles Ca.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
12. CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
2. There must not be any deformations on the housing, lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Damaged rigging points or unsecured
rigging could cause the unit to fall and serious injure a person.
3. All mechanical parts and motors should not show any traces of serious wear and
should rotate freely.
4. Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
Further instructions depending on installation and usage have to be adhered by a skilled
installer and any safety problems should be addressed before attempting operation.
We recommend frequent cleaning of the fixture to ensure operational longevity and crisp
light output. When cleaning, please use a moist, lint-free cloth. Never use alcohol or
solvents.
There are no user serviceable parts inside this fixture with the exception of the lamp. Please
refer all other service related issues to an authorized Elation service technician.
Should you decide to service the fixture yourself please order genuine Elation parts directly
from Elation.
©Elation Professional, Los Angeles Ca.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
13. Photometric Data:
©Elation Professional, Los Angeles Ca.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
17. GOBOS:
©Elation Professional, Los Angeles Ca.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
15. DIMENSIONAL DRAWINGS:
©Elation Professional, Los Angeles Ca.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
16. CIRCUIT SCHEMATICS
©Elation Professional, Los Angeles Ca.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
17. TECHNICAL SPECIFICATIONS
Power supply
100~240v 50/60Hz
Internal Voltage Taps
Power Requirements
Fuse protection
120V = 3.15A/250V, GMA (5x20mm fine-wire fuse)
220V = 2A/250V, GMA (5x20mm fine-wire fuse)
180w (maximum @ at full power)
Power Consumption
Light Source
LED
CTB-90-W
Life Time
60,000 Hours (Rated)
Optical
Parabolic glass reflector
15° standard objective
Lens anti-reflex
Color Mixing
8 dichroic filters plus white, half-color compatible
Gobos
Gobo-wheel: 4 interchangeable rotating gobos plus "open", 3 glass Gobo
Gobo outside diameter 26.9 mm, image size 24 mm
Gobo thickness: glass = 1 mm, steel = 0.4 mm
Shutter / Strobe / Dimmer
Strobe-effect with variable speed 0 - 13 flashes per second
Continuously dimming 0% - 100%
Prism
Rotating 3-face prism, rotating and variable in speed
Focus
Motor driven focus from near to far away
DMX Channels
14 (16bit – default)
DMX Drive
Standard DMX-512, 3 pole & 5 pole XLR; [+] = Pin 3
Starting DMX [001].
[-] = Pin 2
[Ground] = Pin 1.
Pan / Tilt
Pan- movement
Tilt- movement
Weights and measures
Dimensions
630° in max. 2.0 seconds, 16 bit resolution
270° in max. 1.5 seconds, 16 bit resolution
11.42” (H) x 9.57” (W) x 16.02” (D) ~ Head vertical
23 Lbs
Weight (net)
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change
without any prior written notice.
©Elation Professional, Los Angeles Ca.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
©Elation Professional, Los Angeles Ca.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
E SPOT LED™
©Elation Professional, Los Angeles Ca.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Elation Professional®
6122 S. Eastern Ave.
Los Angeles, CA. 90040
323-582-3322 / 323-832-9142 fax
Version 1.0
Rev. 27/10/2009 – visage