ꢀ. Application  
Page  
ꢀ2  
ꢀ2  
ꢀ2  
ꢀ2  
ꢀ3  
ꢀ3  
ꢀ3  
ꢀ4  
ꢀ4  
ꢀ5  
ꢀ5  
ꢀ5  
ꢀ6  
ꢀ6  
ꢀ6  
ꢀ6  
ꢀ6  
ꢀ7  
ꢀ8  
20  
2. Safety instructions  
3. Errors and load restrictions  
4. Safety regulations  
4.ꢀ Special requirements for use in ex-hazardous areas  
5. Safety instructions  
6. Ex-data  
7. Technical data  
8. Functional description / operating information  
8.ꢀ Lite-Ex PL 30 components  
8.2 Getting started  
8.3 Battery replacement  
8.4 Cleaning the twist ring  
8.5 Lamp replacement  
8.6 Replacing the spare disc  
9. Repairs  
ꢀ0. Cleaning, maintenance and storage  
ꢀꢀ. Warranty and liability  
ꢀ2. EC-Type Examination Certificate  
ꢀ3. EC Declaration of Conformity  
Note:  
The current operating instructions, EC Declaration of Conformity and the Ex-certificate  
are available for download from the relevant product page under www.ecom-ex.com  
;
alternatively they can be requested directly from the manufacturer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀꢀ  
1. Application  
The Lite-Ex PL 30 is an LED pocket torch designed for industrial applications or  
use in potentially explosive areas of Zones 2, ꢀ and 0 as well as 22, 2ꢀ and 20 in  
accordance with Directive 99/92/EC (ATEX ꢀ37).  
2. Safety instructions  
These operating instructions contain information and safety regulations that must  
be followed to ensure safe and reliable operation of the unit under the described  
conditions. Failure to follow the information and instructions can have dangerous  
consequences or may contravene applicable regulations.  
Please take the time to carefully read through the owner’s manual before  
you start using the unit. In the event of any doubt or discrepancies (for ex-  
ample, due to translation or printing errors), the German version of these  
operating instructions shall prevail.  
3. Errors and load restrictions  
If there is any risk that the safety or integrity of the unit has been compromised,  
the unit must be taken out of operation immediately and removed from the Ex-area  
without delay.  
Action must be taken to prevent the device from being accidentally placed into  
operation again.  
We recommend sending the unit to the manufacturer to be examined.  
The safety and reliability of the unit may be at risk if, for example:  
- Damage is visible on the housing  
- The unit has been subjected to excessive loads for which it is not designed  
- The unit has been improperly stored  
- The unit has been damaged in transit  
- Labels or markings on the unit are illegible  
- Malfunctions occur  
- Permitted tolerances or threshold values have been exceeded  
In the unlikely event that the product becomes faulty, it is recommended that any  
repairs are carried out only by ecom instruments GmbH as the use of non-ecom  
spare parts invalidates both the warranty and the Ex-certification.  
4. Safety regulations  
Persons using the unit must observe the standard safety regulations and read the  
certificate to prevent incorrect operation or misuse of the unit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ2  
The following additional safety regulations must also be observed:  
- The unit must not be opened within the Ex-area.  
- The batteries must only be changed outside the Ex-area.  
- Additional or spare batteries must not be carried in the Ex-area.  
- Only approved battery types may be used.  
- Only spare sealing rings and discs of ecom instruments are allowed.  
- Only accessories approved by ecom instruments GmbH may be used.  
- Prevent the unit from coming into contact with aggressive acidic or alkaline solutions.  
- Do not open the inside torch head.  
4.1 Special requirements for use in ex-hazardous areas  
- Storing of the torch is prohibited!  
- After changing the batteries or the sealing rings always check to make sure that  
the sealing rings and threads are clean and in good condition.  
- Before using the lamp in the Ex-hazardous area and in order to ensure the IP ra-  
ting, please check that all parts of the unit are hand tightened up to the stop  
– being careful not to over-tighten.  
5. Safety instructions  
Caution! Strong light may blind other people.  
- Do not look directly into the light.  
- Do not shine the light directly into the eyes of other people.  
6. Ex-data  
EC-type examination certificate no.: ZELM 05 ATEX 0272 X  
Ex-designation:  
II ꢀ G EEx ia IIC T4  
II ꢀ D Tꢀ30°C IP65  
Approved for Zones 2, ꢀ and 0, device group II, potentially explosive gases of gas  
group C, vapours or mist, and temperature class T4.  
Approved for Zones 22, 2ꢀ and 20, device group II, potentially explosive dusts, and  
Tꢀ30°C  
The certification assures, that the maximum malfunction-surface-temperature of  
maximum 80% of the temperature class T4 / ꢀ30° C is taken into consideration  
(acc. to EN ꢀꢀ27-ꢀ).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ3  
7. Technical data  
Ambient temperature Ta: -20 ... +50°C  
Storage temperature:  
-30 ... +60°C (without batteries)  
Battery / power supply: 3 x LRꢀ4 (see table)  
Lamp:  
ꢀ high-performance LED (3-watt)  
Operating time:  
Dimensions:  
Weight:  
> 48 hours (continuous)  
approx. 220 mm x 40/45 mm  
approx. 550 g (including batteries)  
IP 65  
IP rating:  
ESD protection:  
CE designation:  
Antistatic housing  
0ꢀ02  
Table of approved battery types  
Manufacturer  
GP  
Type  
Super Alkaline Battery ꢀ4A LRꢀ4  
Energizer No. E93  
Eveready  
Duracell  
Procell MNꢀ400 LRꢀ4  
Powermax 3 LRꢀ4  
Panasonic  
Panasonic  
Energizer  
Powerline Industrial Battery LRꢀ4  
Ucar Gold LRꢀ4  
List of approved sealing rings and discs  
Manufacturer  
ecom  
Type  
sealing rings type PL 30 (complete set)  
spare disc type PL 30  
ecom  
8. Functional description / operating information  
Please take the time to carefully read through these operating instructions to ensure  
that you are familiar with all of the functions of your Lite-Ex PL 30 and know how to  
use all of the functions. For you own safety and information please read through the  
information on the following pages.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ4  
8.1 Lite-Ex PL 30 components  
Illustration 1  
Body of torch  
Sealing rings  
Twist ring  
Battery compartment  
Alignment screw  
Torch head  
Spare disc  
Housing head  
8.2 Getting started  
In order to be able to use the torch in the Ex-area, you must first check that the  
outer housing head and body are screwed on completely. After this has been done,  
you can switch on the torch by turning the yellow twist ring slightly in a clockwise  
direction. The torch is supplied with factory-fitted batteries.  
8.3 Battery replacement  
When the brightness is no longer satisfactory, the batteries should be replaced. It is  
strongly recommended that all three batteries be replaced together. When replacing  
the batteries, only use approved battery types (see table of approved battery types in  
section 7. Technical data).  
To replace the batteries, hold on to the housing head and the twist ring, and turn the  
body of the torch anticlockwise until it comes off. Take the used batteries out of the  
battery compartment, observing correct polarity and replace them with new ones.  
After you insert the new batteries screw the body of the torch back on. Make sure  
that torch components are screwed together securely before switching the torch on.  
Battery replacement  
- Only use approved battery types. See table in section 7. Technical data.  
- Always replace all of the batteries together.  
- Make sure that the polarity of the inserted batteries is correct.  
- Please ensure that all used batteries are properly disposed of in an environmental-  
ly friendly manner.  
- After changing the batteries or the sealing rings always check to make sure that  
the sealing rings and threads are clean and in good condition.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ5  
8.4 Cleaning the twist ring  
A non-contacting twist ring is used to switch on the Lite-Ex PL 30 (see description  
above). Dirt or moisture does not effect the function. The twist ring is easy to clean  
if excessive amounts of dirt and grime have made it difficult to turn. First take off the  
torch body and remove the batteries (see section 8.3 Battery replacement). Remove  
the twist ring by sliding it off the back of the torch, and then clean the ring. When  
putting the twist ring back on, make sure that the arrow marks on the ring line up  
with the alignment screw on the bottom part of the torch head (see illustration ꢀ).  
Then re-insert the batteries, and screw the body of the torch back on.  
8.5 Lamp replacement  
The Lite-Ex PL 30 is equipped with an extremely long-lasting LED lamp. Replacing  
the LED is normally not required. If, however, the torch is defective or the brightness  
of the torch has diminished, it should be sent to ecom instruments for inspection or  
repair. Under no circumstances should you attempt to open the torch head. Manipu-  
lating the torch head or LED on your own poses a risk to the safety of the torch and  
is not permitted.  
8.6 Replacing the spare disc  
The torch head is protected by the housing head that surrounds it as well as an  
additional disc, which is positioned over the opening where the beam is emitted. The  
disc is made of high-quality material. Should, however, the disc break, it is possible  
to replace it. To replace the disc, hold on to the body of the Lite-Ex PL 30 and  
the twist ring, and carefully unscrew the housing head by turning it anticlockwise.  
Clean the housing head thoroughly to remove any remaining pieces, and check the  
sealing ring for damage. After this has been done, you can install a new glass disc  
and, if necessary, new sealing rings. Only spare sealing rings of ecom instruments  
are allowed. The sealing ring is positioned between the housing head and the disc  
(see illustration ꢀ). When putting the housing head back on, ensure that the seal is  
positioned properly on the disc. After installation, you should not be able to see any  
part of the sealing ring through the opening where the beam is emitted. If the inside  
of the torch head or lens is also damaged, the torch should be sent to the manufac-  
turer for repair.  
9. Repairs  
Repair work is subject to the nationally valid regulations and directives. We therefore  
recommend that such work be performed by ecom instruments GmbH, Germany, as  
all repairs must be examined to ensure functional safety.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ6  
10. Cleaning, maintenance and storage  
- Only use a suitable cloth or sponge to clean the unit. Do not use solvents or abra-  
sive cleaning agents to clean the unit.  
- We recommended having the operation and lumen output of the device checked  
by the manufacturer every two years.  
- The batteries should be taken out of the unit if it is to be stored for extended periods.  
- The storage temperature should be within the permitted range of -30°C to +60°C.  
11. Warranty and liability  
Under the general terms and conditions of business, ecom instruments GmbH offers  
a two-year warranty for function and materials on this product when used under the  
specified operating and maintenance conditions. Batteries, LED/Lamps and working  
parts are considered consumable parts and are not covered under the warranty.  
In addition to the standard 2 years manufacturer’s warranty, ecom instruments GmbH  
offers an optional lifetime warranty on the torch housing. This warranty includes dama-  
ge which is incurred only when the device is properly used. Damage to the front disc  
is not included, neither is damage in the form of cosmetic and superficial scratches to  
the housing or to the ‘Ex-certification’ and other text contained on the housing.  
After the 2 years standard warranty period, in the event that the housing has to be  
changed, this optional lifetime warranty does not include any costs that may be  
incurred for inspection, packing and carriage etc. This warranty is only limited by the  
future availability of spare parts. This warranty is invalidated if the torch head unit  
has been opened / tampered with in any way or if the sealing is damaged.  
This warranty does not extend to products that have been used improperly, altered,  
neglected, damaged by accident or subjected to abnormal operating conditions  
or improper handling. In the event of a warranty claim, the faulty device should be  
returned to ecom instruments GmbH. We reserve the right to readjust, repair or  
replace the unit.  
The above warranty terms represent the sole rights of the purchaser to compensation  
and apply exclusively and in place of all other contractual or statutory warranty obli-  
gations. ecom instruments GmbH does not accept liability for specific, direct, indirect,  
incidental or consequential damages or losses, regardless of whether they are caused  
by breach of warranty, lawful or unlawful actions, actions in good faith or other actions.  
If in certain countries the restriction of statutory warranty and the exclusion or re-  
striction of incidental or consequential damages is unlawful, then it may be possible  
that the above restrictions and exclusions do not apply for all purchasers. If any  
clause in these warranty terms should be found to be invalid or unenforceable by a  
competent court, then such a judgement shall not affect the validity or enforceability  
of any other clause contained in these warranty terms.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ7  
12. EC-Type Examination Certificate  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀ9  
13. EC Declaration of Conformity  
Further details relating to the declaration of conformity can be found at the following  
Internet address: http://www.ecom-ex.com in the Product Download area.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
ecom instruments GmbH  
Industriestr. 2  
97959 Assamstadt  
Germany  
Tel.: +49 (0) 62 94 / 42 24-0  
Fax: +49 (0) 62 94 / 42 24-90  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Conair Hair Dryer hair dryer User Manual
Coway Water System P 07FRV User Manual
Cub Cadet Blower HB59L User Manual
Cub Cadet Trimmer CC5090 User Manual
Edimax Technology Printer PS 1001 User Manual
Elation Professional Home Safety Product 100WW User Manual
Fisher Price Model Vehicle V3299 User Manual
Frigidaire Oven 318200943 User Manual
FUNAI TV VCR Combo F9TRF1 User Manual
Gardena Water Pump D 89070 Ulm User Manual