Dynasty Spas Hot Tub MC MP DY4 User Manual

MC-MP-DY4 Spa Pack •  
The Quick Reference Card provides a quick overview of your spa's main  
functions and the operations accessible with your digital control pad.  
Starting Pump 1:  
Turning the light on:  
Press Pump 1 to turn Pump 1 on at low  
speed. Pressing a second time turns Pump 1  
to high speed. A third time turns Pump 1 off.  
When at high speed, a built-in timer turns  
pump off after 20 minutes and when at low  
speed after 2 hours, unless it has been  
manually deactivated.  
Pressing Light key once turns light on at high  
intensity. Pressing a second time turns light to  
low intensity. A third time turns light off.  
A built-in timer turns light off after 2 hours,  
unless it has been manually deactivated.  
the second press. If the LEDs remain off for  
more than 5 sec., the color/  
display sequence will reset and start back at  
the beginning the next time the Light key is  
pressed. Color/ display sequences are:  
The "Light" icon is displayed when  
light is on at high intensity. It flashes  
when light is on at low intensity.  
1• LEDs light up and slowly cycle through all  
six colors. The slow cycle restarts at the  
beginning and repeats.  
The "Pump 1" icon lights up when  
Pump 1 is on at high speed. It flashes  
when Pump 1 is on at low speed.  
2• LEDs light up and remain on in Aqua.  
3• LEDs light up and remain on in Purple.  
4• LEDs light up and remain on in Blue.  
5• LEDs light up and remain on in Gold.  
6• LEDs light up and remain on in Green.  
7• LEDs light up and remain on in Red.  
8• LEDs light up for 2 sec., flash off, then  
flash on in the next color until all six colors  
have been displayed. The flashing cycle  
then repeats itself.  
Fiber Box Option: If spa has an optional fiber  
box only, pressing Light key turns fiber box  
(motor & light) on. Pressing again turns fiber  
box motor off but leaves light on. A third time  
turns both motor and light off. A built-in timer  
turns fiber box off after 2 hours, unless it has  
been manually deactivated. The "Light" icon is  
displayed when fiber box light is on. It flashes  
when fiber box motor and light are on at the  
same time.  
Starting Pump 2:  
Press Pump 2 once to turn Pump 2 on at low  
speed. Pressing a second time turns Pump 2  
to high speed. A third time turns pump off.  
A built-in timer turns pump off after 20 mi-  
nutes, unless manually deactivated first.  
9• LEDs flash on/off quickly for a strobe light  
effect. A built-in timer turns lights off after  
2 hours unless manually deactivated first.  
The "Pump 2" icon lights up when  
Pump 2 is on at high speed. It flashes  
when Pump 2 is on at low speed.  
LED Light Option: If spa has an optional LED  
light, Press Light key to turn LED lights on. To  
advance to the next color/display setting, press  
Light key twice. The LEDs will go off with the  
first press, then back on in the next setting with  
The "Light" icon is displayed  
when light is on.  
Starting the blower:  
Press Blower to turn blower on at high speed.  
Press a second time to turn blower to low  
speed. A third time turns blower off. A built-in  
timer turns blower off after 20 minutes, unless  
manually deactivated first.  
Time & temperature display:  
Temperature display unit:  
Press and hold Light key for 5 seconds to  
display water temperature in either Fahrenheit  
(˚F) or Celsius (˚C).  
The display toggles every 5 seconds alternately  
showing the hourly time and the current water  
temperature.  
The "Blower" icon lights up when  
blower is on at high speed. It flashes  
when blower is on at low speed.  
The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above Set  
Point or if a pump has been started manually. The "Filter" icon will blink (on 0.5 second,  
off 0.5 second, on 0.5 second, off 1.5 seconds).  
Automatic water heater start:  
When water temperature is 1˚F (0.5˚C)  
lower than the Set Point, the heater will  
automatically turn on until water tempera-  
ture reaches Set Point plus 1˚F (0.5˚C).  
Troubleshooting  
The "Heater" icon lights up when the  
heater is on. It flashes when there is a  
request for more heat but the heater  
has not yet started.  
Pumps have started up for  
one minute on several  
occasions and "Filter Cycle"  
icon is flashing.  
Water temperature is  
displayed.  
3 flashing dots are dis-  
played.  
Setting water temperature:  
Water temperature in the  
spa has reached 112˚F  
(44˚C).  
A problem has been de-  
tected.  
Use Up or Down arrow key to regulate water  
temperature. The temperature setting will be  
displayed for 5 seconds to confirm your new  
selection.  
Not a bug but a feature!  
Do not enter the water!  
Check and open water  
valves. Clean filters if nec-  
essary. Check water level.  
Add water if needed.  
Our Smart Winter Mode  
protects your system from  
the cold by automatically  
turning the pumps on for  
one minute several times a  
day to prevent water from  
freezing in pipes.  
Do not enter the water!  
Allow water to cool down.  
The system will reset au-  
tomatically when water  
reaches 109˚F (43˚C).  
The "Set Point" symbol indicates the  
desired temperature, NOT the current  
water temperature!  
Water temperature can be adjusted by 1˚ in-  
crements from 59 to 104˚F (15 to 40˚C).  
Shut power off and power  
your spa up again to reset  
the system.  
Call your dealer or service  
supplier if problem persists.  
Inverted display:  
The display is flashing.  
Call your dealer or service  
supplier if problem persists.  
Press and hold Pump 2 for 5 seconds to invert  
the display. Note that the ˚F or ˚C icon is not  
displayed in reverse mode. Follow the same  
procedure to return to default mode. If a  
power-up occurs, the display always returns  
to default mode.  
A power failure has  
occurred. Press any key  
to reset the system, then  
reprogram all desired  
parameters.  
Download from Www.SQomuaicnukaRls.ecfoemr.eAnllcMeaCnuaarlds Search And Download.  
Temperature  
unit  
Step  
Programming  
7Sequence  
Time of day  
Step 2 Filter cycle start time  
Step 1  
Filter cycle duration  
Step 3  
Step 4  
Step 5  
Step 6  
Step 7  
Filter cycle frequency  
Filter Cycle  
icon  
Heater  
icon  
Up & Down  
arrows  
Economy mode start time  
Economy mode duration  
Programming Mode  
icon  
Economy Mode  
icon  
Lock  
icon  
Storing settings in memory & returning to Normal mode  
Digital control pad lockout  
Step 1- Time of day  
This function allows you to prevent unauthorized parameter  
setting of the unit. This feature is especially helpful when young  
children have access to the keypad.  
Setting the time:  
1- Enter Programming mode by holding  
Prog. key pressed down for 2 seconds.  
2- The display will show the current time.  
3- Use Up and Down arrows to change  
the hours.  
10:25  
11:43  
am  
There are two modes you can choose from: Full lock or Partial  
lock. Full lock means that all keypad functions are locked. Partial  
lock means that the basic functions of the spa will remain accessi-  
ble (pumps, blower and light), but it will be impossible to change  
the temperature Set Point, to override the Economy mode or  
to enter the Programming mode.  
pm  
4- Prog. key a second time to select the  
minutes.  
5- Use Up and Down arrows to change  
setting.  
When control pad is locked, the "Lock" icon will be displayed.  
Steps 2 & 3- Filter cycle start time & duration  
Locking your digital control pad:  
The system automatically performs two filter cycles per day, at  
12-hour intervals. During the filter cycle, Pumps 1 & 2 and the  
blower will run the first minute, then Pump 3 will run for one  
minute. Pump 1 will then run at low speed for a programmed  
number of hours. The "Filter Cycle" icon lights up when a filter  
cycle is on.  
1- Press and hold Pump 1 key for  
5 seconds.  
LocP  
2- The display will show LocP, with "P"  
representing Partial lock.  
3- Release the key and the keypad will be  
LocF  
in Partial lock mode. Keep key pressed  
down for 5 more seconds if you want  
to be in Full lock mode. The "LocF"  
message will then be displayed.  
To program a filter cycle, you must enter: 1) the time you want  
the cycle to start and 2) the duration of the cycle. If no filtering is  
required, the duration should be set to "0". For continuous  
filtering, the filter cycle duration should be set to "12:00".  
When control pad is locked, all automatic functions of the system  
run as usual. If a key is pressed down, a "LocP" or "LocF"  
message will be displayed for 1 second. To unlock the keypad,  
simply press and hold Pump 1 key again for 5 seconds.  
Setting filter cycle start time:  
1- Press Prog. key a third time.  
2- The display will show FSxx, with "xx"  
representing the starting hour.  
3- Use Up and Down arrows to change  
setting.  
FS01  
FS12  
When control pad is unlocked, the "Ulock" icon will be displayed.  
Economy mode  
Setting filter cycle duration:  
1- Press Prog. key a fourth time.  
Press Econo key to switch from Normal mode to Economy  
mode. To save energy, the Economy mode Set Point is 20˚F  
(11˚C) below the Normal mode Set Point.  
2- The display will show Fdxx, with "xx"  
representing the duration in hours.  
3- Use Up and Down arrows to change  
setting.  
Fd00  
Fd12  
The "Economy Mode" icon lights up when Economy  
mode is on.  
Step 4- Filter cycle frequency  
There are 3 available Economy operating modes:  
noEc:  
Ec 1:  
Ec 2:  
No Economy mode  
Economy mode always on  
Economy mode on during a programmed  
number of hours (see Steps 5 & 6*)  
Setting filter cycle frequency:  
1- Press Prog. key a fifth time.  
2- The display will show FFxx, with "xx"  
representing the frequency per day.  
3- Use Up and Down arrows to change  
setting.  
FF01  
Selecting the desired Economy mode:  
FF04  
1- Press and hold Econo key for  
more than 2 seconds.  
2- The display will show the current  
mode (noEc, Ec 1 or Ec 2).  
noEc  
Ec 1  
Steps 5 & 6- Economy mode start time & duration*  
Setting Economy mode start time:  
3- Keep key pressed down until the  
desired mode is displayed.  
1- Press Prog. key a sixth time.  
After 5 seconds, the new setting will be programmed.  
2- The display will show ESxx, with "xx"  
representing the starting hour.  
3- Use Up and Down arrows to change  
setting.  
ES10  
ES08  
Setting Economy mode duration:  
Summary of control panel parameters  
1- Press Prog. key a seventh time.  
2- The display will show Edxx, with "xx"  
representing the duration in hours.  
3- Use Up and Down arrows to change  
setting.  
Ed01  
FSxx Filter cycle start time  
Fdxx Filter cycle duration  
FFxx Filter cycle frequency  
ESxx Economy mode start time  
Edxx Economy mode duration  
LocX Control pad lockout  
Ed04  
Step 7- Storing settings in memory  
Press Prog. key an eighth time to store settings in the system's  
non-volatile memory and to return to Normal mode.  
E
Smart  
Winter  
TM  
Mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9919-100494-B  

Closet Maid Outdoor Storage 6 Cube Storage System User Manual
Coleman Tent 2000001594 User Manual
Country Flame Indoor Fireplace CF 04 User Manual
Craftsman Saw 31510849 User Manual
Dimplex Fan XL6N User Manual
Dimplex Heat Pump SI 5MER User Manual
Dynacord Stereo Amplifier DSA 8204 User Manual
Escient DVD Player M32002 01A2 User Manual
Euro Pro Iron EP485 User Manual
Generac Power Systems Portable Generator 0784 1 User Manual