REMOTE CONTROL USUAGE  
The corner wall mounted electric fireplace is supplied with a radio frequency remote control.  
This remote control has a range of approximately 50 feet (15.25m), it does not have to be  
pointed at the fireplace and can pass through most obstacles (including walls). It is supplied  
with one of 243 independent frequencies to prevent interference with other units. The  
frequency designation is indicated on the back of the transmitter.  
A. Remote Control Initialization  
This procedure is required every time there is a loss  
of power to the remote control in the fireplace.  
(i.e. power failure, breaker tripped, main power switch  
is turned off)  
1. Ensure that power is supplied through main  
service panel.  
2. Locate manual controls. (refer to FIGURE 13)  
3. Activate main power switch, red indicator light 1  
will flash.  
4. Press and hold the heater control switch for five  
seconds. The second red indictor light will flash.  
5. Press ON button located on the remote control  
transmitter (FIGURE 14). This will synchronize  
the remote control transmitter and receiver.  
B. Remote Control Usage  
The remote control operates the fireplace levels  
sequentially. The level is increased every time the  
ON button on the transmitter is pressed. The  
fireplace can be turned off at any point by pressing  
the OFF button on the remote control transmitter.  
FIGURE 14  
Manual  
Selection  
Switch  
Level 1: The flame effect is turned on and the first red  
indicator light is activated.  
Main  
Power  
Switch  
Level 2: The flame effect remains on, the heater is  
activated to the low heat setting, and the first and  
second red indicator lights are activated.  
Level 3: The flame effect remains on, the heater is  
set to the high heat setting, and all three red indicator  
lights are activated.  
Level 3 Indicator  
Level 2 Indicator  
Level 1 Indicator  
FIGURE 15  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
MANUAL CONTROLS  
The corner wall mounted electric fireplace can also be controlled in a similar manner to the  
remote control with switches located inside the unit (FIGURE 15).  
A. Main Power Switch  
Main on/off switch, supplies power to the remote control receiving unit. When placed in the  
on position Level 1 indicator will flash.  
B. Manual Selection Switch  
Operates the corner wall mounted electric fireplace in the same manner as the remote  
control transmitter. Pressing the left side of this switch has the same effect as the ON  
button on the remote control and the right side has the same effect as the OFF button of  
the remote control. Pressing once to the left activates Level 1, twice activates Level 2,  
three times activates Level 3. Pressing to the right turns the corner wall mounted electric  
fireplace off.  
MAINTENANCE  
WARNING  
Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire,  
electric shock or damage to persons.  
LIGHT BULB REPLACEMENT  
Allow at least 5 minutes for light bulbs to cool before touching bulbs to avoid accidental burning  
of skin.  
Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity  
and detail of the log exterior disappears. There are two bulbs under the log set which generate  
the flames and embers.  
TOOL REQUIREMENTS  
Slot screw driver  
HELPFUL HINTS  
It is a good idea to replace all light bulbs at one time if they are close to the end of their rated  
life. Group replacement will reduce the number of times you need to open the unit to replace  
light bulbs.  
LOWER LIGHT BULB REQUIREMENTS  
Two (2) clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt rating.  
LOWER BULB REPLACEMENT  
1. Unplug the unit from the outlet.  
2. Open latched door.  
3. Remove the 3 mounting bracket screws.  
4. Set aside mounting bracket.  
5. Remove 2 log set screws.  
6. Set log set assembly aside.  
7. Unscrew the bulb(s) counter clockwise.  
8. Insert new bulb(s).  
9. Assemble in reverse order.  
NOTE  
When placing log set back into unit ensure the log set sits in between the 2 vertical  
mounting flanges.  
10.Plug in the corner wall mounted electric fireplace.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cobra Electronics GPS Receiver SL3 User Manual
Coleman Trimmer 2000004412 User Manual
Cooper Lighting Indoor Furnishings CFE 4 User Manual
CyberData Stereo Amplifier 4 Port User Manual
Eaton Electrical Automobile Parts MTR3 User Manual
Faber Ventilation Hood Diamante Isola User Manual
Fujitsu Laptop A26391 K220 Z125 1 5619 User Manual
Generac Power Systems Portable Generator 0940 1 User Manual
GE Oven JKP75BMBB User Manual
GE Washer GFWN1000 User Manual