Electrical Connection
Important Safety Advice
WARNING THISAPPLIANCE MUST BE EARTHED
If the socket outlets in your home are not of the 13 amp BS1363
type they will not accept the plug connected to this heater, therefore
cut off the plug. When cut off this plug can constitute a shock
hazard if inserted into a socket outlet. It must therefore be
disposed of safely.
Before wiring the appropriate plug please note that the wires in
this mains lead are coloured in accordance with the following
code.
WARNING –THIS APPLIANCE MUST NOT BE USED IN A
BATHROOM.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OFABATH,ASHOWER ORASWIMMING
POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED
IMMEDIATELYBELOWAFIXED SOCKET OUTLET.
GREEN/YELLOW:
BLUE:
BROWN:
EARTH
NEUTRAL
LIVE
The plug must be accessible after heater installation.
Connect the Green/Yellow wire to the terminal marked E or the
DO NOT USE THE HEATER UNTIL THE FEET OR WALL
BRACKETSARE FITTED CORRECTLY.
earth symbol or coloured Green or Green/Yellow.
Connect the Brown wire to the terminal marked L or coloured
Red.
FOLLOW these instructions carefully.
Connect the Blue wire to the terminal marked N or coloured
Black.
DO NOT connect the Brown (Live) or the Blue (Neutral) wires to
the Earth terminal of your 13 amp plug. If the terminals of the
plug are unmarked or you are in any doubt, consult a qualified
electrician.
CAUTION: If you use this heater in conjunction with a thermal
control, programme controller, timer or any other device which
switches the heater on automatically observe all safety warnings
at all times.
The heater carries a warning ‘DO NOT COVER’ to alert the
user to the risk of fire that exists if the heater is
accidentally covered.
Models DXLWP400TI, DXLWP800TIN and ARLWP800TI
can be set to switch on automatically. Remember to
observe all safety warnings at all times.
This appliance is not intended for use by children or other
persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.
If young children, the aged or infirm are likely to be left in
the vicinity of the heater, we advise that adequate
precautions should be taken. We recommend a guard
be fitted to ensure contact with the heater is avoided and
objects cannot be inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or
for further advice contact the Customer Helpline.
Download from Www.Somanuals.com. All Manuals Search And Download.
Models with Timer
DXLWP400TI, DXLWP800TI N & ARLWP800TI
15
Set the I - ¡ - O slide switch on the timer
(Fig. 3) to :
14
I
Position O - Heating Off
Position I - Manual operation
1 2
This setting allows power to the heater
uninterrupted by the timer settings. The
heat selector switch will control the output
O
1 1
(see ‘Using the heater’).
Fig. 3
Position ¡ - ‘Auto’ operation
DO NOT disconnect this heater from
15
the mains supply unless it is being
taken out of use (e.g. in summer or for
14
I
storage), otherwise the timer clock will
stop.
1 2
O
1 1
Setting the time of day
To set the time of day, rotate the timer
dial clockwise (indicated by the arrow)
until the correct time of day is opposite
Fig. 4
the reference mark
(see Fig. 4).
The 24-hour clock is used ; e.g. time shown for 3 pm is ‘15’
(15:00hrs).
Setting the ‘Auto’ ON and OFF times
To set the timer :
1. Using your finger tip or the tip of a
pencil, push in as many segments as
necessary around the dial, according
to the times you don’t require heat –
see Fig. 4. Each segment pushed in
switches the heater OFF for that part of
the hour.All other segments will be ON.
For example, Fig. 5 shows the timer
set to switch the heater ON between 7
am and 9 am and between 4 pm and
9.30 pm .
Fig. 5
2. You can select as many ON periods
as you like, within the 24-hour day. The
settings will repeat every day until changed.
3. To change ON and OFF times, simply push in any ‘ON’
segments you wish to cancel and pull out new ‘ON’ segments
as required.
Switching to auto
Set the heat selector and thermostat for the heat output required.
Check that the clock shows the correct time of day. Set the I - ¡
- O slide switch to ¡ (see Fig. 4) - the convector will switch ON
and OFF according to the timer settings (see Fig 5).
IMPORTANT NOTES
Remember to observe all safety warnings when operating the
heater on auto setting unattended or attended .
If the mains supply to the heater is interrupted, the timer clock
will stop until power is restored ; reset the time of day to ensure
correct ON and OFF times.
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning
WARNING –ALWAYS DISCONNECT FROM THE POWER SUPPLY
BEFORECLEANINGTHEHEATER.
Do not use detergents, abrasive cleaning powder or polish of
any kind on the body of the heater.
Allow the heater to cool, then wipe with a dry cloth to remove dust
and a damp cloth (not wet) to clean off stains. Be careful not to
allow moisture into the heater.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it
should not be disposed of with household waste.
Please recycle where facilities exist. Check with
your Local Authority or retailer for recycling advice
in your country.
After Sales Service
Your product is guaranteed for three years from the date of
purchase.
Within this period, we undertake to repair or exchange this product
free of charge (subject to availability) provided it has been
installed and operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory
rights, which in turn are not affected by this guarantee.
Should you require after sales service you should contact our
customer services help desk on 0870 727 0101. It would assist
us if you can quote the model number, series, date of purchase,
and nature of the fault at the time of your call. The customer
services help desk will also be able to advise you should you
need to purchase any spares.
Please do not return a faulty product to us in the first instance as
this may result in loss or damage and delay in providing you with
a satisfactory service.
Please retain your receipt as proof of purchase.
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and
EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336
Glen Dimplex UK Limited
Millbrook House
Grange Drive
Hedge End
Southampton
UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)
Customer Services:
Tel.
0870 7270101
Fax.
e-mail
Tel.
0870 7270102
01 8424833
Republic of Ireland
Hampshire. SO30 2DF
[c] Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.
Download from Www.Somanuals.com. All Manuals Search And Download.
|