VR15 & VR20RPQuartzray Vector Heaters
08/18149/1
(UK) Issue 1
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility
(EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimplex VR15 & VR20RP Quartzray Vector Heaters
THESEINSTRUCTIONSSHOULDBEREADCAREFULLYANDRETAINEDFORFUTUREREFERENCE
Vector VR20RP - Patio
Models
Similar to Vector VR15 but rain cover must be removed
before front assembly can be removed (see Fig. 5).
Heating Elements Voltage
Weight
2.2kg
VR15
1 x 1.5kW
1 x 2.0kW
230-240V
230-240V
Important
VR20RP
2.2kg
The supply cable MUST enter the back box from below on
this rain-proof model to prevent water entering the heater. If
the heater is to be wall mounted the two screws/nuts retaining
Important Safety Advice
the cover support bracket will need to be removed.
The installation of these appliances must always be
carried out by a competent electrician and be in
accordance with the current IEE wiring regulations and
relevant Building Regulations.
Installation
The minimum mounting height from ground/floor is 1.8
metres for both models.
The radiated heat from the heater is considerable and
must be taken into account when siting the heater.
Ensure that the heater is not used in close proximity to
the skin or eyes.
The heater should not be mounted in enclosed areas. The
minimum distance to an end wall is 1.0 metre. Large objects
should also be kept 1.0 metre away from the front of the
heater. Allow a minimum space of 150mm to any overhang
or ceiling - see Fig. 1.
Always isolate the heater from the supply before
undertaking any maintenance work of the appliance.
Do not locate the heater above or below any socket outlet.
The Vector VR15 model is designed for internal use only,
whilst the VR20RP Patio Vector model can be internally
or externally installed. Both heaters are not rated as
flame-proof and must not be used when flammable dusts,
gases, or vapours, etc., are likely to be present in the
atmosphere. If in doubt, advice should be sought from
the Health and Safety Executive inspectors or local fire
officers.
VR15
a.
b.
c.
Wall mounting – screw back box to wall using 2 holes
(see Fig. 3).
Bracket mounting – fit bracket to wall and back box to
bracket (see Fig. 6).
Suspended mounting – remove 2 knockouts (see Fig.
3) and suspend back box using conduit or chain hooks.
Quartz lamps are extremely fragile and must be handled
with extreme care at all times. Avoid touching the surface
of the quartz sleeve with bare fingers. If the sleeve is
accidentally touched remove the finger print with a soft
cloth moistened with methylated spirits.
VR20RP - Patio
a. Bracket mounting only – fit bracket to wall and back box
(cover
support
fitted)
to
wall
bracket
(see Fig. 6).
As with any fragile fitting mounted above head height,
care must be taken when siting the heater to avoid
locations where it may be subjected to knocks. In high
risk areas such as sports halls etc. extra guarding may
be required to protect the heater from flying objects. If in
doubt consult the heater manufacturer.
IMPORTANT When deciding upon the best location,
consideration must be given to the following requirements.
a. Avoid structures liable to vibration, e.g. crane gantries,
which could otherwise adversely affect lamp life.
b. The lamps are designed to operate within 5° of the
horizontal plane. It is very important to ensure that the
heater is mounted horizontally, otherwise the operating
life of the lamp could be impaired.
WARNING - THIS APPLIANCE MUST BE EARTHED.
HEATERS MUST BE MOUNTED OUT OF REACH FROM
OVERHEAD WALKWAYSAND OPENING WINDOWS. THE
HEATER MUST BE SECURELY FIXED AS IT WILL BE
DANGEROUS IN THE EVENT OF ANY INSECURITY IN ITS
FIXINGS.
c. Ensure appliance is mounted the correct way up so that
it can be tilted down but not up.
d. WARNING – THESE HEATERS ARE DESIGNED TO BE
WALL MOUNTED, BRACKET MOUNTED, OR
SUSPENDED MOUNTED – THEY MUST NOT BE
CEILING MOUNTED. THEY MUST NOT BE MOUNTED
IN A ROOM CONTAINING A BATH OR SHOWER. DO
NOT MOUNT HEATERS CLOSER THAN 3.5 METRES
FROM CURTAINS OR SIMILAR SOFT FURNISHINGS.
General
The Dimplex Vector range is available in two models, 1.5kW
for internal use and a 2.0kW, which is suitable for both
internal and external installation. Both models are suitable
for permanent connection to a 230-240V 1PN supply.
Electrical
Wiring to the heater must be installed in compliance with the
requirement of the IEE Regulations and any local or
insurance regulations.
Assembly
Vector VR15
All heaters are suitable for use on 230-240V single phase
supplies.
Remove the front assembly (see Fig. 2) and disconnect
the lamp leads from the terminal block. Remove
knockout(s) as shown in Fig. 3. DO NOT attempt to
remove knockouts on assembled heater as this will
cause damage to the fragile lamps.
Wiring between the heater and the spur outlet or isolation
switch must be in a heat resisting cable with a temperature
rating of T150. Sufficient slack cable must be left to allow for
angular adjustment of the heater body.
If a guard is to be fitted it is necessary to remove one
end cap from the heater front (see Fig. 4).
An all-pole isolating switch with a minimum separation of
3mm in each pole must be fitted adjacent to the heater to
Download from Www.Somanuals.com. All Manuals Search And Download.
facilitate local isolation.
2.
3.
Clean the lamp(s) and reflector(s) using a mild
detergent solution and soft cloth. Do not use any
abrasive or caustic cleaners. Dry with a soft cloth.
Avoid touching either the quartz lamp sleeve or the
aluminium reflector with bare fingers. If they are
accidentally touched remove any finger prints using a
soft cloth moistened with methylated spirit.
If miniature circuit breakers are to be used to avoid ‘nuisance
tripping’ due to the high in rush at switch on, a type ‘C’ MCB
with a tripping coefficient of 7-10 times rated current should
be used. Any other switching device should be Tungsten
lamp load rated.
Always ensure that the cable grip is tightened.
Check that the lamp(s) are properly located in the
spring retaining clips and that they have not been
disturbed by cleaning. The lamps should be pushed
fully back into the clips by applying light pressure on
IMPORTANT Ensure the electrical supply cable is routed
and restrained to prevent contact with the external
surfaces of the heater and is not positioned in the direct
heat beam.
the end caps only.
When heater is close to a ceiling the reflectors must be rotated
to avoid the heat beam from directly overheating it. The
reflector must point down at more than 30° from the
horizontal.
Safety in Operation
The heater is operated by simply switching on the electrical
supply, or, if used in conjunction with a control system, then
the supplier’s instructions must be observed.
Always ensure that the heat beam is parallel to or angled
away from a side wall when mounted close to and end wall
to avoid overheating wall surfaces. The minimum distance
to an end wall is 1.0m.
ALWAYS disconnect the heater from the supply before
attempting to work on or near it.
NEVER operate the heater with a high accumulation of dust
or dirt on the lamp(s) or reflector or with a damaged or
corroded reflector.
It is important that the user is instructed not to stack
inflammable material in the direct heat beam.
NEVER use the heater where flammable dusts, gases or
vapours, etc., are likely to be present in the atmosphere.
Maintenance
Since the Dimplex Vector Heater contains no moving parts
little maintenance is required beyond cleaning and lamp
replacement. It is however essential that the heater is not
operated with accumulation of dust or dirt on the lamp(s) or
reflector(s) as this can cause a build up of heat and eventual
damage . For this reason the heater must be inspected
regularly, depending upon conditions and at least at yearly
intervals.
NEVER operate the heater in close proximity to the skin or
eyes.
NEVER allow materials which could be damaged or ignited
by the radiated heat to be placed in close proximity to the
heater.
NEVER cover the heater – even when it is switched off.
ALWAYS refer to these instructions before attempting to
dismantle the heater.
Before undertaking any maintenance work on the heater due
attention must be paid to the following,
After Sales Service
Your product is guaranteed for one year from the date of
purchase.
1.
2.
3.
Always disconnect the heater from the electricity supply
before attempting to work on or near it.
Always ensure a safe means of access using an
access tower or properly supported ladder.
Within this period, we undertake to repair or exchange this
product free of charge (excluding lamps & subject to
availability) provided it has been installed and operated in
accordance with these instructions. Your rights under the
guarantee are additional to your statutory rights, which in
turn are not affected by this guarantee.
Some types of quartz lamps run with an internal
pressure in excess of atmospheric and while
construction is very strong there is a slight risk of
shattering. If it is necessary to examine a bare lamp
whilst in operation then a protective screen must be
used.
Should you require after sales service, you should contact
our customer services help desk on 0870 727 0101. It would
assist us if you can quote the model number, series, date of
purchase, and nature of the fault at the time of your call. The
customer services help desk will also be able to advise you
should you need to purchase any spares.
4.
Allow adequate time for the lamps and body casing to
cool before attempting to work on the heater.
Inspection and Cleaning
1.
Check that all the lamps are functioning. If any
thermostatic or time controls are fitted ensure that the
supply is ‘off’ before checking lamps. Any failed lamps
should be replaced (see lamp replacement).
Remove any accumulated dirt and check wiring and
connections.
Please do not return a faulty product to us in the first instance
as this may result in loss or damage and delay in providing
you with a satisfactory service.
Please retain you receipt as proof of purchase.
Glen Dimplex UK Limited
Millbrook House
Grange Drive
Hedge End
Southampton
UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)
Customer Services:
Tel.
0870 7270101
Fax.
e-mail
Tel.
0870 7270102
01 8424833
Hampshire. SO30 2DF
Republic of Ireland
[c] Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.
Download from Www.Somanuals.com. All Manuals Search And Download.
|