| Installation and Operating Instructions   08/50511/0   Issue 0   Air Warmer: Model No. HAW1000N   Dimensions   (millimetres)   Watts Electrical Supply Weight (kg)   HAW1000N   1000   230-240V ~1PN   14   115   207   470   Fig. 1   THESE INSTRUCTIONS SHOULD BE READ CAREFULLYAND RETAINED FOR FUTURE REFERENCE   Important Safety Advice   Do not locate above or below a fixed socket outlet.   The heater including the supporting legs can get very hot;   therefore do not mount directly on any combustible   material. Suitable fire resistant material is required   between the heater and any combustible base or support.   Warning: Before obtaining access to the terminals all supply   circuits must be disconnected.   The heater should be installed to allow a reasonable air   flow around the heater.   A prominent notice should be provided where the heater   is sited ‘Keep Clear and Unobstructed’.   x Avoid exposure to water.   The heaters are not suitable for general domestic use.   The heater is suitable for a drying room provided that the   heater has suitable ventilation.   Fig. 2   A mains lead which can operate at + 110°C must be used.   Installation   An all-pole isolating switch with a minimum separation of   3mm in each pole must be fitted adjacent to the heater to   facilitate local isolation.   The installation should be carried out by a suitably qualified electrician/   engineer in accordance with applicable standards.   Remove all items from the packaging. The heater should be fixed using   the fixing points provided - see Fig. 3. Ensure the heater is securely   fastened.   General   This carton contains:   • • 1 HAW1000N heater   1 Foldable guard   Electrical connection   WARNING – THISAPPLIANCE MUST BE EARTHED.   Verify that the electrical supply cable is sufficient for the rated loading.   Check that the incoming supply conforms to the rated supply.   179   The heater power circuit must be protected by a suitably rated over   current device.   449   The incoming cables must be connected to the factory fitted heater   terminals provided. Do not alter any factory fitted wiring.   Fig. 3   The Terminal Cover Casting can be removed to access the terminals, by   removing the 2 screws fixing the cover - see Fig. 2.   Remove the terminal cover and connect the mains cable, while making   note of the path the connecting cable should take through the guard.   WARNING: Ensure the power cable path does not come into contact   with the heater element.   Reattach the terminal cover to the heater and fasten the cable gland.   The heater is supplied with an earth stud, located inside the terminal box,   which must be connected to earth.   Mount the guard over the heater. Ensure the guard is mounted centrally   relative to the heater as shown in Fig. 4.   After connection check the continuity of earth connections.   The heater should not be connected until the instruction leaflet has been   read fully.   Download from Www.Somanuals.com. All Manuals Search And Download.   |