Delta Electronics Power Supply S36SS User Manual

FEATURES  
High efficiency: 81% @ 3.3V/4.5A  
Standard footprint  
Surface mountable  
Industry standard pin out  
Size: 45.5mm x 28.0mm x 12.2mm  
(1.79” x 1.10” x 0.48”)  
Fixed frequency operation  
Input UVLO, OVLO, Output OCP, OVP  
No minimum load required  
Wide Input voltage range: 18V~60V  
ISO 9001, TL 9000, ISO 14001, QS9000,  
OHSAS18001 certified manufacturing  
facility  
UL/cUL 60950 (US & Canada) recognized,  
and TUV (EN60950) certified  
CE mark meets 73/23/EEC and  
93/68/EEC directive  
Delphi Series S36SS, 15W Family  
DC/DC Power Modules: 18Vin to 60Vin, 3.3V/4.5A out  
OPTIONS  
Positive on/off logic  
The Delphi Series S36SS, surface mountable, wide ranging input, single  
output, isolated DC/DC converter, is the latest offering from a world  
leader in power system and technology and manufacturing – Delta  
Electronics, Inc. This product family provides up to 15 watts of power or  
up to 4.5A of output current in an industry standard footprint. With  
creative design technology and optimization of component placement, the  
Delphi Series Small Power converters possess outstanding electrical and  
thermal performance, as well as extremely high reliability under highly  
stressful operating conditions. All models are protected from abnormal  
input/output voltage and current conditions.  
APPLICATIONS  
Telecom/DataCom  
Wireless Networks  
Optical Network Equipment  
Server and Data Storage  
Industrial/Test Equipment  
DATASHEET  
DS_S36SS3R304_04062006  
1
Delta Electronics, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
90  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
85  
80  
75  
70  
65  
18Vin  
24Vin  
48Vin  
60Vin  
18Vin  
24Vin  
60  
55  
48Vin  
60Vin  
50  
0.5  
1
1.5  
2
2.5  
3
3.5  
4
4.5  
0.5  
1
1.5  
2
2.5  
3
3.5  
4
4.5  
OUTPUT CURRENT(A)  
OUTPUT CURRENT (A)  
Figure 1: Efficiency vs. load current for minimum, nominal, and  
Figure 2: Power dissipation vs. load current for minimum,  
maximum input voltage at 25°C.  
nominal, and maximum input voltage at 25°C.  
1.00  
Io=4.5A  
I0=2.7A  
Io=0.45  
0.80  
0.60  
0.40  
0.20  
0.00  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
INPUT V OLTA GE (V )  
Figure 3: Typical input characteristics at room temperature.  
Figure 4: Turn-on transient at full rated load current (resistive  
load) (2 ms/div). Top Trace: Vout (1V/div); Bottom Trace:  
ON/OFF Control (2V/div).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Figure5: Turn-on transient at zero load current (2 ms/div). Top  
Trace: Vout (1V/div); Bottom Trace: ON/OFF Control (2V/div).  
Figure 6: Output voltage response to step-change in load  
current (50%-100%-50% of Io, max; di/dt = 0.1A/µs). Load  
cap: 10µF, 100 mESR tantalum capacitor and 1µF  
ceramic capacitor. Top Trace: Vout (50mV/div), Bottom  
Trace: Iout (2A/div).  
i
s
TEST  
12uH  
Cs:68uF/100V  
Vi(+)  
Vi(-)  
68uF/100V  
ESR< 0.3  
ESR< 0.3  
20100KHz  
20100KHz  
Figure 7: Test set-up diagram showing measurement points for  
Input Reflected Ripple Current (Figure 8).  
Note: Measured input reflected-ripple current with a simulated  
Figure 8:. Input Reflected Ripple Current, i , at full rated  
output current and nominal input voltage with 12µH source  
impedance and 68µF electrolytic capacitor (2 mA/div).  
s
source Inductance (LTEST) of 12 µH. Capacitor Cs offset possible  
battery impedance.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Copper Strip  
Vo(+)  
SCOPE  
RESISTIVE  
LOAD  
10u  
1u  
Vo(-)  
Figure 9: Output voltage noise and ripple measurement test  
setup. Scope measurement should be made using a BNC  
cable (length shorter than 20 inches). Position the load  
between 51 mm to 76 mm (2 inches to 3 inches) from the  
module.  
Figure 10: Output voltage ripple at nominal input voltage and  
rated load current (20 mV/div). Load capacitance: 1µF ceramic  
capacitor and 10µF tantalum capacitor. Bandwidth: 20 MHz.  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
Vin=48V  
0.0  
0.0  
2.0  
4.0  
6.0  
8.0  
LOAD CURRENT (A)  
Figure 11: Output voltage vs. load current showing typical  
current limit curves and converter shutdown points.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN CONSIDERATION  
This power module is not internally fused. To achieve  
optimum safety and system protection, an input line  
fuse is highly recommended. The safety agencies  
require a normal-blow fuse with 3A maximum rating to  
be installed in the ungrounded lead. A lower rated fuse  
can be used based on the maximum inrush transient  
energy and maximum input current.  
Input Source Impedance  
The impedance of the input source connecting to the  
DC/DC power modules will interact with the modules  
and affect the stability. A low ac-impedance input  
source is recommended. If the source inductance is  
more than a few µH, we advise adding a 10 to 100 µF  
electrolytic capacitor (ESR < 0.7 at 100 kHz)  
mounted close to the input of the module to improve the  
stability.  
Soldering and Cleaning Considerations  
Post solder cleaning is usually the final board assembly  
process before the board or system undergoes  
electrical testing. Inadequate cleaning and/or drying  
may lower the reliability of a power module and  
severely affect the finished circuit board assembly test.  
Adequate cleaning and/or drying is especially important  
for un-encapsulated and/or open frame type power  
modules. For assistance on appropriate soldering and  
cleaning procedures, please contact Delta’s technical  
support team.  
Layout and EMC Considerations  
Delta’s DC/DC power modules are designed to operate  
in a wide variety of systems and applications. For  
design assistance with EMC compliance and related  
PWB layout issues, please contact Delta’s technical  
support team. An external input filter module is  
available for easier EMC compliance design.  
Application notes to assist designers in addressing  
these issues are pending release.  
Safety Considerations  
The power module must be installed in compliance with  
the spacing and separation requirements of the end-  
user’s safety agency standard if the system in which the  
power module is to be used must meet safety agency  
requirements.  
When the input source is 60Vdc or below, the power  
module meets SELV (safety extra-low voltage)  
requirements. If the input source is a hazardous voltage  
which is greater than 60 Vdc and less than or equal to  
75 Vdc, for the module’s output to meet SELV  
requirements, all of the following must be met:  
The input source must be insulated from any  
hazardous voltages, including the ac mains, with  
reinforced insulation.  
One Vi pin and one Vo pin are grounded, or all the  
input and output pins are kept floating.  
The input terminals of the module are not operator  
accessible.  
A SELV reliability test is conducted on the system  
where the module is used to ensure that under a  
single fault, hazardous voltage does not appear at  
the module’s output.  
Do not ground one of the input pins without grounding  
one of the output pins. This connection may allow a non-  
SELV voltage to appear between the output pin and  
ground.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
20.373 32.637 ×0.1  
3.3×0.1+ 0.018  
FEATURES DESCRIPTIONS  
Rtrim down =  
10.2 = 38.96  
[
ΚΩ  
]
Over-Current Protection  
Vo(+)  
The modules include an internal output over-current  
protection circuit, which will endure current limiting for  
an unlimited duration during output overload. If the  
output current exceeds the OCP set point, the modules  
will automatically shut down (hiccup mode).  
Trim  
Rtrim-up  
Vo(-)  
The modules will try to restart after shutdown. If the  
overload condition still exists, the module will shut down  
again. This restart trial will continue until the overload  
condition is corrected.  
Figure 13: Circuit configuration for trim-up (increase output  
voltage)  
Over-Voltage Protection  
If the external resistor is connected between the TRIM  
and Vo - the output voltage set point increases. The  
external resistor value required to obtain a percentage  
output voltage change Vo% is defined as:  
12.2636  
The modules include an internal output over-voltage  
protection circuit, which monitors the voltage on the  
output terminals. If this voltage exceeds the over-  
voltage set point, the module will shut down (Hiccup  
mode). The modules will try to restart after shutdown. If  
the fault condition still exists, the module will shut down  
again. This restart trial will continue until the fault  
condition is corrected.  
Rtrim up =  
[
10.2 ΚΩ  
]
3.3Vo 0.018  
Ex. When trim-up +10% (3.3V X 1.1 = 3.63V)  
12.2636  
Output Voltage Adjustment (TRIM)  
Rtrim up =  
[
10.2 = 29.11 ΚΩ  
]
3.3×0.10.018  
To increase or decrease the output voltage set point, the  
modules may be connected with an external resistor  
between the TRIM pin and either the Vo+ or Vo -. The  
TRIM pin should be left open if this feature is not used.  
Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
Remote ON/OFF  
Vo(+)  
The remote on/off feature on the module can be either  
negative or positive logic. Negative logic turns the  
module on during a logic low and off during a logic high.  
Positive logic turns the modules on during a logic high  
and off during a logic low. Remote on/off can be  
controlled by an external switch between the on/off  
terminal and the Vi(-) terminal. The switch can be an  
open collector or open drain. If the remote on/off feature  
is not used, please short the on/off pin to Vi(-) for  
negative logic and let the pin open for positive logic.  
Rtrim-down  
Trim  
Vo(-)  
Figure 12: Circuit configuration for trim-down (decrease output  
voltage)  
Vi(+)  
Vo(+)  
If the external resistor is connected between the TRIM  
and Vo+ pins, the output voltage set point decreases.  
The external resistor value required to obtain a  
percentage of output voltage change Vo% is defined  
as:  
ON/OFF Trim  
20.373 32.673Vo  
3.3Vo +0.018  
Rtrim down =  
[
10.2 ΚΩ  
]
Vi(-)  
Vo(-)  
Ex. When trim-down –10% (3.3V X 0.9 = 2.97V)  
Figure 14: Circuit configuration for remote ON/OFF  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
THERMAL CONSIDERATIONS  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel. The space between the neighboring PWB  
and the top of the power module or a heat sink is  
6.35mm (0.25”).  
Thermal Derating  
Heat can be removed by increasing airflow over the  
module. The module’s hot spot temperature is defined at  
+105°C.  
To enhance system reliability, the power  
module should always be operated below the maximum  
operating temperature. If the temperature exceeds the  
maximum module temperature, reliability of the unit may  
be affected.  
PWB  
MODULE  
FACING PWB  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
MEASURED BELOW  
THE MODULE  
50.8 (2.0”)  
AIR FLOW  
10 (0.4”)  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 15: Wind tunnel test setup  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
THERMAL CURVES  
S36SS3R304(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 60V  
Output Current(A)  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
Natural  
Convection  
100LFM  
200LFM  
300LFM  
400LFM  
500LFM  
600LFM  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 16: Temperature measurement location. Pin locations  
are for reference only.  
The allowed maximum hot spot temperature is defined at  
Figure 19: Output current vs. ambient temperature and air  
velocity (Vin=60V)  
105℃  
S36SS3R304(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 24V  
Output Current(A)  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
Natural  
Convection  
100LFM  
200LFM  
300LFM  
400LFM  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 17: Output current vs. ambient temperature and air  
velocity (Vin=24V)  
S36SS3R304(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 48V  
Output Current(A)  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
Natural  
Convection  
100LFM  
200LFM  
300LFM  
400LFM  
500LFM  
600LFM  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 18: Output current vs. ambient temperature and air  
velocity (Vin=48V)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
MECHANICAL DRAWING  
Pin No.  
Name  
+Vout  
-Vout  
Trim  
NC  
Function  
1
2
3
Positive output voltage  
Negative output voltage  
Output voltage trim  
No Connection  
4
5
NC  
No Connection  
6
NC  
No Connection  
7
NC  
No Connection  
8
9
ON/OFF  
NC  
ON/OFF Logic  
No Connection  
10  
11  
12  
NC  
-Vin  
+Vin  
No Connection  
Negative input voltage  
Positive input voltage  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PART NUMBERING SYSTEM  
S
36  
S
S
3R3  
04  
N
R
F
A
Form  
Factor  
S- Small  
Power  
Input  
Voltage  
36- 18V~ 60V  
Number of Product  
Output  
Voltage Current  
3R3- 3.3V 04- 4.5A  
Output  
ON/OFF  
Logic  
N- Negative R- SMD Pin  
Pin Type  
Option  
Code  
A- Standard  
Outputs  
Series  
S- Single  
S- SMD  
Space-RoHS 5/6  
P- Positive  
Function  
F- RoHS 6/6  
(Lead Free)  
MODEL LIST  
MODEL NAME  
INPUT  
OUTPUT  
EFF @ 100% LOAD  
S36SS3R304NRFA  
18V- 60V  
1.3A  
3.3V  
4.5A  
81%  
USA:  
Telephone:  
East Coast: (888) 335 8201  
West Coast: (888) 335 8208  
Fax: (978) 656 3964  
Europe:  
Phone: +41 31 998 53 11  
Fax: +41 31 998 53 53  
Asia & the rest of world:  
Telephone: +886 3 4526107 ext 6220  
Fax: +886 3 4513485  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available  
upon request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta  
for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license  
is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise  
these specifications at any time, without notice.  
11
Download from Www.Somanuals.com. All Manuals Search And Download.  

Coleman Tent 2000001585 User Manual
Continental Electric Blender CE22161 User Manual
Cooper Lighting Indoor Furnishings 1484 User Manual
Craftsman Drill 32017217 User Manual
Creative Speaker SB1380 User Manual
Digital Spectrum Digital Photo Frame NV 800 User Manual
Electro Voice DJ Equipment SB121 User Manual
Electro Voice Portable Speaker E V Sixteen User Manual
GE Monogram Dishwasher ZBD6800KBB User Manual
GE Toaster 106701 User Manual