FEATURES  
High efficiency: 87% @ 1.8V/40A  
Standard footprint:  
57.9x36.8x10.2mm (2.28”x1.45”x0.40”)  
Industry standard pin out  
Fixed frequency operation  
Wide output trim range: 0.8V~1.9V  
Fully protected: OTP, OVP, OCP, UVLO  
No minimum load required  
Fast transient response  
Start up into pre-biased load  
Basic insulation  
ISO 9000, TL 9000, ISO 14001 certified  
manufacturing facility  
UL/cUL 60950 (US & Canada) Recognized,  
and TUV (EN60950) Certified  
CE mark meets 73/23/EEC and 93/68/EEC  
directives  
Delphi Series Q48SR, 165W Quarter Brick Family  
DC/DC Power Modules: 48V in, 1.8V/40A out  
The Delphi Series Q48SR Quarter Brick, 48V input, adjustable single  
output, isolated, open frame DC/DC converters are the latest offering  
from a world leader in power systems technology and manufacturing   
Delta Electronics, Inc. This product family provides up to 165 watts of  
power or up to 60A of output current in an industry standard footprint.  
This product represents the next generation of design technology which  
may be utilized to provide high levels of current at very low output  
voltages required by today’s leading-edge circuitry. Utilizing an  
advanced patented thermal and electrical design technology; the Delphi  
Series Q48SR converters are capable of providing higher output current  
capability with excellent transient response and lower common mode  
noise. Featuring a wide operating output voltage range and high current  
at low output voltages, these units offer more useable power over a  
wide range of ambient operating conditions. The wide range trimmable  
output feature allows the user to both reduce and standardize part  
numbers across different and/or migrating voltage requirements. This  
model covers the output range of 0.8V to 1.9V at 40A.  
OPTIONS  
Short lead lengths  
Non-latching over voltage protection  
Negative trim  
Positive on/off logic  
APPLICATIONS  
Telecom/DataCom  
Wireless Networks  
Optical Network Equipment  
Server and Data Storage  
Industrial/Test Equipment  
Datasheet  
DS_Q48SR1R840_12212004  
Delta Electronics, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
95  
24.0  
20.0  
16.0  
12.0  
8.0  
36Vin  
48Vin  
75Vin  
36Vin  
48Vin  
75Vin  
90  
85  
80  
75  
70  
65  
60  
4.0  
0.0  
5
10  
15  
20  
25  
30  
35  
40  
5
10  
15  
20  
25  
30  
35  
40  
OUTPUT CURRENT(A)  
OUTPUT CURRENT (A)  
Figure 1: Efficiency vs. load current for minimum, nominal, and  
Figure 2: Power dissipation vs. load current for minimum,  
maximum input voltage at 25°C. (Vout=1.8V)  
nominal, and maximum input voltage at 25°C. (Vout=1.8V)  
85  
80  
75  
70  
65  
14.0  
36Vin  
48Vin  
75Vin  
12.0  
10.0  
8.0  
6.0  
4.0  
36Vin  
48Vin  
75Vin  
2.0  
0.0  
60  
10  
20  
30  
40  
10  
20  
30  
40  
OUTPUT CURRENT(A)  
OUTPUT CURRENT (A)  
Figure 3: Efficiency vs. load current for minimum, nominal, and  
Figure 4: Power dissipation vs. load current for minimum,  
maximum input voltage at 25°C. (Vout=0.8 V)  
nominal, and maximum input voltage at 25°C. (Vout=0.8V)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
15.0  
14.0  
13.0  
12.0  
11.0  
10.0  
9.0  
95  
93  
91  
89  
87  
85  
83  
81  
79  
36Vin  
48Vin  
75Vin  
8.0  
7.0  
6.0  
36Vin  
48Vin  
1.4  
75Vin  
77  
75  
5.0  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
0.8  
1.0  
1.2  
1.6  
1.8  
OUTPUT VOLTAGE (V)  
OUTPUT VOLTAGE (V)  
Figure 5: Efficiency vs. output voltage for minimum, nominal,  
Figure 6: Power dissipation vs. output voltage for minimum,  
and maximum input voltage at 25°C. (Iout=40A)  
nominal, and maximum input voltage at 25°C. (Iout=40A)  
3.0  
Io=40A  
Io=24A  
Io=4A  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
30 35 40 45 50 55 60 65 70 75  
INPUT VOLTAGE (V)  
Figure 7: Typical input characteristics at room temperature  
Figure 8: Turn-on transient at full rated load current (resistive  
load) (5 ms/div). Top Trace: Vout; 1V/div; Bottom Trace:  
ON/OFF input: 2V/div  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Figure 9: Turn-on transient at zero load current (5 ms/div).  
Top Trace: Vout: 1V/div; Bottom Trace: ON/OFF input:  
2V/div  
Figure 10: Output voltage response to step-change in load  
current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:  
10µF, tantalum capacitor and 1µF ceramic capacitor. Top Trace:  
Vout (50mV/div), Bottom Trace: Iout (20A/div). Scope  
measurement should be made using a BNC cable (length shorter  
than 20 inches). Position the load between 51 mm to 76 mm (2  
inches to 3 inches) from the module..  
Figure 11: Output voltage response to step-change in load  
current (75%-50%-75% of Io, max: di/dt = 2.5A/µs). Load  
cap: 470µF, 35mESR solid electrolytic capacitor and 1µF  
ceramic capacitor. Top Trace: Vout (100mV/div), Bottom  
Trace: Iout (20A/div). Scope measurement should be made  
using a BNC cable (length shorter than 20 inches). Position  
the load between 51 mm to 76 mm (2 inches to 3 inches)  
from the module.  
Figure 12: Test set-up diagram showing measurement points for  
Input Terminal Ripple Current and Input Reflected Ripple Current.  
Note: Measured input reflected-ripple current with a simulated  
source Inductance (LTEST) of 12 µH. Capacitor Cs offset possible  
battery impedance. Measure current as shown above.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
Figure 13: Input Terminal Ripple Current, ic, at full rated  
output current and nominal input voltage with 12µH source  
impedance and 33µF electrolytic capacitor (500 mA/div).  
Figure 14: Input reflected ripple current, is, through a 12µH  
source inductor at nominal input voltage and rated load current  
(5 mA/div).  
Copper Strip  
Vo(+)  
SCOPE  
RESISTIVE  
LOAD  
10u  
1u  
Vo(-)  
Figure 15: Output voltage noise and ripple measurement  
test setup  
Figure 16: Output voltage ripple at nominal input voltage and  
rated load current (20 mV/div). Load capacitance: 1µF ceramic  
capacitor and 10µF tantalum capacitor. Bandwidth: 20 MHz.  
Scope measurement should be made using a BNC cable (length  
shorter than 20 inches). Position the load between 51 mm to 76  
mm (2 inches to 3 inches) from the module.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CHARACTERISTICS CURVES  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0.0  
Vin=48V  
20  
0
10  
30  
40  
50  
60  
LOAD CURRENT (A)  
Figure 17: Output voltage vs. load current showing typical  
current limit curves and converter shutdown points.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN CONSIDERATIONS  
Input Source Impedance  
Do not ground one of the input pins without grounding  
one of the output pins. This connection may allow a  
non-SELV voltage to appear between the output pin  
and ground.  
The impedance of the input source connecting to the  
DC/DC power modules will interact with the modules  
and affect the stability. A low ac-impedance input  
source is recommended. If the source inductance is  
more than a few µH, we advise adding a 10 to 100 µF  
electrolytic capacitor (ESR < 0.7 at 100 kHz)  
mounted close to the input of the module to improve the  
stability.  
The power module has extra-low voltage (ELV) outputs  
when all inputs are ELV.  
This power module is not internally fused. To achieve  
optimum safety and system protection, an input line  
fuse is highly recommended. The safety agencies  
require a normal-blow fuse with 20A maximum rating to  
be installed in the ungrounded lead. A lower rated fuse  
can be used based on the maximum inrush transient  
energy and maximum input current.  
Layout and EMC Considerations  
Delta’s DC/DC power modules are designed to operate  
in a wide variety of systems and applications. For  
design assistance with EMC compliance and related  
PWB layout issues, please contact Delta’s technical  
support team. An external input filter module is  
available for easier EMC compliance design.  
Application notes to assist designers in addressing  
these issues are pending release.  
Soldering and Cleaning Considerations  
Post solder cleaning is usually the final board assembly  
process before the board or system undergoes  
electrical testing. Inadequate cleaning and/or drying  
may lower the reliability of a power module and  
severely affect the finished circuit board assembly test.  
Adequate cleaning and/or drying is especially important  
for un-encapsulated and/or open frame type power  
modules. For assistance on appropriate soldering and  
cleaning procedures, please contact Delta’s technical  
support team.  
Safety Considerations  
The power module must be installed in compliance with  
the spacing and separation requirements of the end-  
user’s safety agency standard, i.e., UL60950,  
CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and  
IEC60950-1999, if the system in which the power  
module is to be used must meet safety agency  
requirements.  
When the input source is 60 Vdc or below, the power  
module meets SELV (safety extra-low voltage)  
requirements. If the input source is a hazardous voltage  
which is greater than 60 Vdc and less than or equal to  
75 Vdc, for the module’s output to meet SELV  
requirements, all of the following must be met:  
The input source must be insulated from any  
hazardous voltages, including the ac mains, with  
reinforced insulation.  
One Vi pin and one Vo pin are grounded, or all the  
input and output pins are kept floating.  
The input terminals of the module are not operator  
accessible.  
A SELV reliability test is conducted on the system  
where the module is used to ensure that under a  
single fault, hazardous voltage does not appear at  
the module’s output.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES DESCRIPTIONS  
Vi(+)  
Vo(+)  
Over-Current Protection  
The modules include an internal output over-current  
protection circuit, which will endure current limiting for  
an unlimited duration during output overload. If the  
output current exceeds the OCP set point, the modules  
will automatically shut down (hiccup mode).  
Sense(+)  
ON/OFF  
Sense(-)  
Vi(-)  
Vo(-)  
The modules will try to restart after shutdown. If the  
overload condition still exists, the module will shut down  
again. This restart trial will continue until the overload  
condition is corrected.  
Figure 18: Remote on/off implementation  
Remote Sense  
Over-Voltage Protection  
Remote sense compensates for voltage drops on the  
output by sensing the actual output voltage at the point  
of load. The voltage between the remote sense pins  
and the output terminals must not exceed the output  
voltage sense range given here:  
The modules include an internal output over-voltage  
protection circuit, which monitors the voltage on the  
output terminals. If this voltage exceeds the over-  
voltage set point, the module will shut down and latch  
off. The over-voltage latch is reset by cycling the input  
power for one second.  
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] 10% × Vout  
Over-Temperature Protection  
This limit includes any increase in voltage due to  
remote sense compensation and output voltage set  
point adjustment (trim).  
The over-temperature protection consists of circuitry  
that provides protection from thermal damage. If the  
temperature exceeds the over-temperature threshold  
the module will shut down.  
Vi(+) Vo(+)  
Sense(+)  
The module will try to restart after shutdown. If the over-  
temperature condition still exists during restart, the  
module will shut down again. This restart trial will  
continue until the temperature is within specification.  
Sense(-)  
Vi(-) Vo(-)  
Remote On/Off  
Contact  
Resistance  
Contact and Distribution  
Losses  
The remote on/off feature on the module can be either  
negative or positive logic. Negative logic turns the  
module on during a logic low and off during a logic high.  
Positive logic turns the modules on during a logic high  
and off during a logic low.  
Figure 19: Effective circuit configuration for remote sense  
operation  
If the remote sense feature is not used to regulate the  
output at the point of load, please connect SENSE(+)  
to Vo(+) and SENSE(–) to Vo(–) at the module.  
Remote on/off can be controlled by an external switch  
between the on/off terminal and the Vi(-) terminal. The  
switch can be an open collector or open drain.  
The output voltage can be increased by both the  
remote sense and the trim; however, the maximum  
increase is the larger of either the remote sense or the  
trim, not the sum of both.  
For negative logic if the remote on/off feature is not  
used, please short the on/off pin to Vi(-). For positive  
logic if the remote on/off feature is not used, please  
leave the on/off pin floating.  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
Care should be taken to ensure that the maximum  
output power does not exceed the maximum rated  
power.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES DESCRIPTIONS (CON.)  
Output Voltage Adjustment (TRIM)  
To increase or decrease the output voltage set point,  
connect an external resistor between the TRIM pin  
and either the SENSE(+) or SENSE(-). The TRIM pin  
should be left open if this feature is not used.  
Figure 21: Circuit configuration for trim-down (decrease  
output voltage)  
If the external resistor is connected between the TRIM  
and SENSE (-) the output voltage set point decreases  
(Fig. 21). The external resistor value required to obtain  
a percentage output voltage change % is defined  
as:  
Figure 20: Circuit configuration for trim-up (increase output  
voltage)  
10ΚΩ  
If the external resistor is connected between the TRIM  
and SENSE (+) pins, the output voltage set point  
increases (Fig. 20). The external resistor value  
required to obtain a percentage of output voltage  
change % is defined as:  
Rtrim_down  
(
)
=
11kΩ  
where  
Vonom = nominal Vout (3.3V or 1.8V)  
= trim expressed as decimal fraction, i.e. 40% is  
written as 0.4  
Vonom  
(
1+ ∆  
)
Vref  
Rtrim_up() =  
10k11kΩ  
Ex. When trim down to 0.8V from 1.8V  
Vref∆  
Vonom = 1.8V  
= (1.8-0.8)/1.8 = 0.5556  
10K  
where  
Vonom = nominal Vout (3.3V or 1.8V)  
Vref = 1.225V  
= trim expressed as decimal fraction, i.e. 10% is written  
as 0.1  
Rtrim down =  
11KΩ = 7KΩ  
0.5556  
The output voltage can be increased by both the remote  
sense and the trim, however the maximum increase  
allowed is the larger of either the remote sense spec or  
the trim spec, not the sum of both.  
Ex. When trim up to 1.9V from 1.8V  
Vonom = 1.8V  
Vref = 1.225V  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
= (1.9-1.8)/1.8 = 0.05556  
(
1.8×1.05556 1.225  
)
Rtrim up =  
×10KΩ  
1.225*0.05556  
11KΩ = 88.18KΩ  
Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
Output voltage  
Resistor value ( k)  
1.5V  
1.2V  
1.0V  
0.9V  
0.8V  
49.00  
19.00  
11.50  
9.0  
7.0  
Figure 22: Trim resistor value example for popular output  
voltages. Connect the resistor between the TRIM and  
SENSE (-) pins.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THERMAL CONSIDERATIONS  
THERMAL CURVES  
Thermal management is an important part of the  
system design. To ensure proper, reliable operation,  
sufficient cooling of the power module is needed over  
the entire temperature range of the module. Convection  
cooling is usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
Figure 24: Hot spot location  
The allowed maximum hot spot temperature is defined at 114℃  
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel. The space between the neighboring PWB  
and the top of the power module is constantly kept at  
6.35mm (0.25’’).  
Thermal Derating  
Heat can be removed by increasing airflow over the  
module. The module’s maximum device temperature is  
114 and the measured location is illustrated in Figure  
24. To enhance system reliability, the power module  
should always be operated below the maximum  
operating temperature. If the temperature exceeds the  
maximum module temperature, reliability of the unit  
may be affected.  
PWB  
MODULE  
FACING PWB  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
MEASURED BELOW  
THE MODULE  
50.8 (2.0”)  
AIR FLOW  
12.7 (0.5”)  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inche  
Figure 23: Wind tunnel test setup  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THERMAL CURVES (CON.)  
Q48SR1R840(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 48V, Vo = 1.8V (Tranverse Orientation)  
Output Current(A)  
45  
40  
35  
30  
25  
20  
15  
10  
5
Natural  
Convection  
100LFM  
200LFM  
300LFM  
400LFM  
500LFM  
600LFM  
0
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 25: Output current vs. ambient temperature and air  
velocity (Vin=48V, Vout=1.8V, transverse orientation)  
Q48SR1R840(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 48V, Vo = 1.5V (Tranverse Orientation)  
Output Current(A)  
45  
40  
35  
30  
25  
20  
15  
10  
5
Natural  
Convection  
100LFM  
200LFM  
300LFM  
400LFM  
500LFM  
600LFM  
0
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 26: Output current vs. ambient temperature and air  
velocity (Vin=48V, Vout=1.5V, transverse orientation)  
Q48SR1R840(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 48V, Vo = 1.0V (Tranverse Orientation)  
Output Current(A)  
45  
40  
35  
30  
25  
20  
15  
10  
5
Natural  
Convection  
100LFM  
200LFM  
300LFM  
400LFM  
500LFM  
600LFM  
0
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 27: Output current vs. ambient temperature and air  
velocity (Vin=48V, Vout=1.0V, transverse orientation)  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MECHANICAL DRAWING  
Pin No.  
Name  
-Vin  
ON/OFF  
+Vin  
+Vout  
+SENSE  
TRIM  
-SENSE  
-Vout  
Function  
Negative input voltage  
Remote ON/OFF  
Positive input voltage  
Positive output voltage  
Positive remote sense  
Output voltage trim  
Negative remote sense  
Negative output voltage  
1
2
3
4
5
6
7
8
Notes:  
1
2
3
Pins 1-3, 5-7 are 1.00mm (0.040”) diameter  
Pins 4 and 8 are 1.50mm (0.060”) diameter  
All pins are copper with tin plating  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PART NUMBERING SYSTEM  
The part numbering system for Delta’s Q48SR DC/DC converters have the following format:  
Q
48  
Input  
Voltage  
48V  
S
R
1R8  
40  
N
R
Pin  
Length  
A
Form Factor  
Number of  
Outputs  
S - Single  
Product  
Series  
R - Single  
Board  
Output  
Voltage  
1R8 - 1.8V  
Output  
Current  
40 - 40A  
ON/OFF  
Logic  
N - Negative R - 0.170”  
P - Positive  
Space Option Code  
Q - Quarter  
Brick  
A - Standard  
Functions  
N - 0.145”  
K - 0.110”  
MODEL LIST  
MODEL NAME  
Q48SR1R840NR A  
Q48SR1R860NR A  
Q48SR3R335NR A  
Q48SR3R350NR A  
INPUT  
OUTPUT  
EFF @ 100% LOAD  
36V~75V  
36V~75V  
36V~75V  
36V~75V  
2.7A  
0.8V - 1.9V  
40A - 72W  
60A - 108W  
35A - 115W  
50A - 165W  
87%  
88%  
90%  
91%  
4.0A  
4.2A  
5.9A  
0.8V - 1.9V  
1.7V - 3.6V  
1.7V - 3.6V  
Note: Please contact us for factory pre-set fixed output voltages.  
USA:  
Europe:  
Asia & the rest of world:  
Telephone:  
Telephone: +41 31 998 53 11  
Fax: +41 31 998 53 53  
Telephone: +886 3 4526107 x6220  
Fax: +886 3 4513485  
East Coast: (888) 335 8201  
West Coast: (888) 335 8208  
Fax: (978) 656 3964  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available  
upon request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta  
for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license  
is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise  
these specifications at any time, without notice.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion Car Video System OHM102 OHM153 User Manual
Crate Amplifiers Musical Instrument Amplifier MX15R User Manual
Ecom Instruments Bluetooth Headset EX TRA BT User Manual
Edimax Technology Network Router BR 6004 User Manual
Electro Voice Microphone 637 User Manual
Electro Voice Portable Speaker MTH 4 64B User Manual
Extron electronic Stereo Amplifier DVI 104 User Manual
Extron electronic Stereo Receiver IR Link User Manual
Fellowes Paper Shredder PS 67Cs User Manual
Frigidaire Ventilation Hood FHWC3640MS User Manual