Dell™ PowerVault™ Modular Disk 3000i
Systems Installation Guide
w w w. d e l l . c o m | s u p p o r t . d e l l . c o m
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1
Introduction
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
2
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
13
Direct-Attached Solutions
.
.
.
.
.
.
Network-Attached Solutions .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Installing MD Storage Software.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
Installing MD Storage Software on an iSCSI-attached Host
Server (Windows).
Installing MD Storage Software on an iSCSI-attached Host
Server (Linux) .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
25
27
Installing a Dedicated Management Station (Windows and Linux) .
Contents
3
Download from Www.Somanuals.com. All Manuals Search And Download.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
28
28
Viewing Resource CD Contents.
.
.
Installing the Manuals
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
Using iSNS .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
45
45
45
46
46
What is CHAP?
Target CHAP
Mutual CHAP .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
CHAP Definitions .
How CHAP Is Set Up
4
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are using Windows Server 2003 or Windows Server 2008
.
.
.
.
57
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Viewing the status of your iSCSI connections .
5
.
.
.
.
.
.
Windows Host Setup.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
63
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
64
Configuring TCP/IP on Linux using DHCP (root users only)
Configuring TCP/IP on Linux using a Static IP address
65
(root users only).
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
65
Index
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
67
Contents
5
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
This guide outlines the steps for configuring the Dell™ PowerVault™ Modular Disk 3000i
(MD3000i). The guide also covers installing the MD Storage Manager software, installing and
®
configuring the Microsoft iSCSI and Linux initiators, and accessing documentation from the
PowerVault MD3000i Resource CD. Other information provided includes system requirements,
storage array organization, initial software startup and verification, and discussions of utilities and
premium features.
MD Storage Manager enables an administrator to configure and monitor storage arrays for optimum
®
®
usability. MD Storage Manager operates on both Microsoft Windows and Linux operating
systems and can send alerts about storage array error conditions by either e-mail or Simple Network
Management Protocol (SNMP). These alerts can be set for instant notification or at regular intervals.
System Requirements
Before installing and configuring the MD3000i hardware and MD Storage Manager software, ensure
that the operating system is supported and minimum system requirements are met. For more
information, refer to the Dell™ PowerVault™ MD3000i Support Matrix available on
support.dell.com.
Management Station Hardware Requirements
A management station uses MD Storage Manager to configure and manage storage arrays across the
network. Any system designated as a management station must be an x86-based system that meets
the following minimum requirements:
®
®
•
•
•
•
•
Intel Pentium or equivalent CPU (133 MHz or faster)
128 MB RAM (256 MB recommended)
120 MB disk space available
Administrator or equivalent permissions
Minimum display setting of 800 x 600 pixels with 256 colors (1024 x 768 pixels with 16-bit color
recommended)
Introduction
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction to Storage Arrays
A storage array includes various hardware components, such as physical disks, RAID controller modules,
fans, and power supplies, gathered into enclosures. An enclosure containing physical disks accessed
through RAID controller modules is called a RAID enclosure.
One or more host servers attached to the storage array can access the data on the storage array. You can
also establish multiple physical paths between the host(s) and the storage array so that loss of any single
path (through failure of a host server port, for example) does not result in total loss of access to data on the
storage array.
The storage array is managed by MD Storage Manager software running either on a host server or a
dedicated management station. On a host server system, MD Storage Manager and the storage array
communicate management requests and event information directly via iSCSI ports. On a dedicated
management station, MD Storage Manager communicates with the storage array either through an
Ethernet connection on the RAID controller modules or via the host agent installed on the host server.
Using MD Storage Manager, you configure the physical disks in the storage array into logical components
called disk groups, then divide the disk groups into virtual disks. You can make as many disk groups and
virtual disks as your storage array configuration and hardware permit. Disk groups are created in the
unconfigured capacity of a storage array, while virtual disks are created in the free capacity of a disk
group.
Unconfigured capacity is comprised of the physical disks not already assigned to a disk group. When a
virtual disk is created using unconfigured capacity, a disk group is automatically created. If the only
virtual disk in a disk group is deleted, the disk group is also deleted. Free capacity is space in a disk group
that has not been assigned to a virtual disk.
Data is written to the physical disks in the storage array using RAID technology. RAID levels define the
way in which data is written to physical disks. Different RAID levels offer different levels of accessibility,
redundancy, and capacity. You can set a specified RAID level for each disk group and virtual disk on your
storage array.
You can also provide an additional layer of data redundancy by creating disk groups that have a RAID
level other than 0. Hot spares can automatically replace physical disks marked as Failed.
For more information on using RAID and managing data in your storage solution, see the Dell™
PowerVault™ Modular Disk Storage Manager User’s Guide.
8
Introduction
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
This chapter provides guidelines for planning the physical configuration of your Dell™ PowerVault™
MD3000i storage array and for connecting one or more hosts to the array. For complete information
on hardware configuration, see the Dell™ PowerVault™ MD3000i Hardware Owner’s Manual.
Storage Configuration Planning
Consider the following items before installing your storage array:
•
•
•
•
Evaluate data storage needs and administrative requirements.
Calculate availability requirements.
Decide the frequency and level of backups, such as weekly full backups with daily partial backups.
Consider storage array options, such as password protection and e-mail alert notifications for error
conditions.
•
Design the configuration of virtual disks and disk groups according to a data organization plan.
For example, use one virtual disk for inventory, a second for financial and tax information, and a
third for customer information.
•
•
Decide whether to allow space for hot spares, which automatically replace failed physical disks.
If you will use premium features, consider how to configure virtual disk copies and snapshot
virtual disks.
About the Enclosure Connections
The RAID array enclosure is connected to an iSCSI-enabled host server via one or two RAID
controller modules. The RAID controller modules are identified as RAID controller module 0 and
RAID controller module 1 (see the PowerVault MD3000i Hardware Owner’s Manual for more
information).
Each RAID controller module contains two iSCSI In port connectors that provide direct connections
to the host server or switches. iSCSI In port connectors are labeled In-0 and In-1(see the PowerVault
MD3000i Hardware Owner’s Manual for more information).
Each MD3000i RAID controller module also contains an Ethernet management port and a SAS Out
port connector. The Ethernet management port allows you to install a dedicated management
station (server or standalone system). The SAS Out port allows you to connect the RAID enclosure
to an optional expansion enclosure (MD1000) for additional storage capacity.
Hardware Installation
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Cabling the Enclosure
You can connect up to 16 hosts and two expansion enclosures to the storage array.
To plan your configuration, complete the following tasks:
1
2
3
4
Evaluate your data storage needs and administrative requirements.
Determine your hardware capabilities and how you plan to organize your data.
Calculate your requirements for the availability of your data.
Determine how you plan to back up your data.
The iSCSI interface provides many versatile host-to-controller configurations. For the purposes of this
manual, the most conventional topologies are described. The figures in this chapter are grouped
according to the following general categories:
•
•
Direct-attached solutions
Network-attached (SAN) solutions
Redundancy vs. Nonredundancy
Nonredundant configurations, configurations that provide only a single data path from a host to the
RAID enclosure, are recommended only for non-critical data storage. Path failure from a failed or
removed cable, a failed NIC, or a failed or removed RAID controller module results in loss of host access
to storage on the RAID enclosure.
Redundancy is established by installing separate data paths between the host and the storage array, in
which each path is to different RAID controller modules. Redundancy protects the host from losing
access to data in the event of path failure, because both RAID controllers can access all the disks in the
storage array.
Direct-Attached Solutions
You can cable from the Ethernet ports of your host servers directly to your MD3000i RAID controller
iSCSI ports. Direct attachments support single path configurations (for up to four servers) and dual path
data configurations (for up to two servers) for both single and dual controller modules.
RAID controller through a single physical Ethernet port. Because there is only the single port, there is no
redundancy (although each iSCSI portal supports multiple connections). This configuration is
supported for both single controller and dual controller modes.
Figure 2-1 and Figure 2-2 show the supported nonredundant cabling configurations to MD3000i RAID
controller modules using the single path data configuration. Figure 2-1 shows a single controller array
configuration. Figure 2-2 shows how four standalone servers are supported in a dual controller array
configuration.
10
Hardware Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-1. One or Two Direct-Attached Servers (or Two-Node Cluster), Single-Path Data, Single Controller (Simplex)
2
3
1
Management traffic
5
4
1
4
standalone (one or
two) host server
2
5
two-node cluster
3
Ethernet
management port
MD3000i RAID
Enclosure (single
controller)
corporate, public or
private network
Hardware Installation
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-2. Up to Four Direct-Attached Servers, Single-Path Data, Dual Controllers (Duplex)
1
Management traffic
2
4
3
1
4
standalone (up to
four) host server
2
Ethernet management
port (2)
3
MD3000i RAID
Enclosure (dual
controllers)
corporate, public or
private network
Dual Path Data Configuration
In Figure 2-3, up to two servers are directly attached to the MD3000i RAID controller module. If the host
server has a second Ethernet connection to the array, it can be attached to the iSCSI ports on the array’s
second controller. This configuration provides improved availability by allowing two separate physical
paths for each host, which ensures full redundancy if one of the paths fail.
12
Hardware Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-3. One or Two Direct-Attached Servers (or Two-Node Cluster), Dual-Path Data, Dual Controllers (Duplex)
2
1
3
5
4
1
4
standalone (one or
two) host server
2
5
two-node cluster
3
Ethernet
management port
(2)
MD3000i RAID
Enclosure (dual
controllers)
corporate, public or
private network
You can also cable your host servers to the MD3000i RAID controller iSCSI ports through an IP storage
area network (SAN) industry-standard 1GB Ethernet switch. By using an IP SAN "cloud" Ethernet
switch, the MD3000i RAID controller can support up to 16 hosts simultaneously with multiple
connections per session. This solution supports either single- or dual-path data configurations, as well as
either single or dual controller modules.
Figure 2-4 shows how up to 16 standalone servers can be attached (via multiple sessions) to a single
MD3000i RAID controller module through a network. Hosts that have a second Ethernet connection to
the network allow two separate physical paths for each host, which ensures full redundancy if one of the
paths fail. Figure 2-5 shows how the same number of hosts can be similarly attached to a dual MD3000i
RAID controller array configuration.
Hardware Installation
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-4. Up to 16 SAN-Configured Servers, Single-Path Data, Single Controller (Simplex)
1
2
3
5
4
1
4
up to 16 standalone
host servers
2
5
IP SAN (Gigabit
Ethernet switch)
3
Ethernet
management port
MD3000i RAID
Enclosure (single
controller)
corporate, public or
private network
14
Hardware Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-5. Up to 16 Dual SAN-Configured Servers, Dual-Path Data, Dual Controllers (Duplex)
1
2
3
5
4
1
4
up to 16 standalone
host servers
2
5
IP SAN (dual Gigabit
Ethernet switches)
3
Ethernet
management port
(2)
MD3000i RAID
Enclosure (dual
controllers)
corporate, public or
private network
Attaching MD1000 Expansion Enclosures
One of the features of the MD3000i is the ability to add up to two MD1000 expansion enclosures for
additional capacity. This expansion increases the maximum physical disk pool to 45 3.5" SAS and/or
SATA II physical disks.
As described in the following sections, you can expand with either a brand new MD1000 or an MD1000
that has been previously configured in a direct-attach solution with a PERC 5/E system.
NOTICE: Ensure that all MD1000 expansion enclosures being connected to the MD3000i are first updated to the
latest Dell MD1000 EMM Firmware (available from support.dell.com). Dell MD1000 EMM Firmware versions prior to
A03 are not supported in an MD3000i array; attaching an MD1000 with unsupported firmware causes an uncertified
condition to exist on the array. See the following procedure for more information.
Hardware Installation
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Expanding with Previously Configured MD1000 Enclosures
Use this procedure if your MD1000 is now directly attached to and configured on a Dell PERC 5/E
system. Data from virtual disks created on a PERC 5 SAS controller cannot be directly migrated to an
MD3000i or to an MD1000 expansion enclosure connected to an MD3000i.
NOTICE: If an MD1000 that was previously attached to PERC 5 SAS controller is used as an expansion enclosure
to an MD3000i, the physical disks of the MD1000 enclosure will be reinitialized and data will be lost. All data on the
MD1000 must be backed up before attempting the expansion.
Perform the following steps to attach previously configured MD1000 expansion enclosures to the MD3000i:
1
2
Back up all data on the MD1000 enclosure(s).
While the enclosure is still attached to the PERC 5 controller, upgrade the MD1000 firmware to
version A03 or above. Windows systems users can reference the DUP.exe package; for Linux kernels,
users can reference the DUP.bin package.
3
Before adding the MD1000 enclosure(s), make sure the MD3000i software is installed and up to date.
For more information, refer to the Dell
support.dell.com
™
PowerVault
™
MD3000i Support Matrix available on
.
a
b
Install or update (to the latest version available on support.dell.com) the MD Storage Manager on
each host server. Install or update (to the latest version available on support.dell.com) the
multipath drivers on each host server. The multipath drivers are bundled with Modular Disk
Storage Management install. On Windows systems, the drivers are automatically installed when a
Full or Host selection is made.
Using the MD Storage Manager, update the MD3000i RAID controller firmware to the latest
version available on support.dell.com
Controller Module Firmware) and the NVSRAM (Support
RAID Controller Module NVSRAM).
(
Support
→
Download Firmware
→
Download RAID
Download
→
Download Firmware
→
4
5
Stop I/O and turn off all systems:
a
b
c
Stop all I/O to the array and turn off affected host systems attached to the MD3000i.
Turn off the MD3000i.
Turn off the MD1000 enclosure(s).
Referencing the applicable configuration for your rack (Figure 2-1 through Figure 2-5), cable the
MD1000 enclosure(s) to the MD3000i.
16
Hardware Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Turn on attached units:
a
b
Turn on the MD1000 expansion enclosure(s). Wait for the enclosure status LED to light blue.
Turn on the MD3000i and wait for the status LED to indicate that the unit is ready:
•
•
If the status LEDs light a solid amber, the MD3000i is still coming online.
MD Storage Manager.
•
If the status LEDs light a solid blue, the MD3000i is ready.
c
After the MD3000i is online and ready, turn on any attached host systems.
7
After the MD1000 is configured as the expansion enclosure to the MD3000i, restore the data that was
backed up in step 1.
After they are online, the MD1000 enclosures are available for use within the MD3000i system.
Expanding with New MD1000 Enclosures
Perform the following steps to attach new MD1000 expansion enclosures to the MD3000i:
1
Before adding the MD1000 enclosure(s), make sure the MD3000i software is installed and up to date.
For more information, refer to the Dell PowerVault MD3000i Support Matrix available on
support.dell.com
™
™
.
a
b
c
Install or update (to the latest version available on support.dell.com) the MD Storage Manager on
each host server.
Install or update (to the latest version available on support.dell.com) the multipath drivers on
each host server.
Using the MD Storage Manager, update the MD3000i RAID controller firmware
(
Support
→
NVSRAM (Support
Download Firmware
→
Download RAID Controller Module Firmware) and the
→
Download Firmware
→
2
3
Stop I/O and turn off all systems:
a
b
c
Stop all I/O to the array and turn off affected host systems attached to the MD3000i.
Turn off the MD3000i.
Turn off any MD1000 enclosures in the affected system.
Referencing the applicable configuration for your rack (Figure 2-1 through Figure 2-5), cable the
MD1000 enclosure(s) to the MD3000i.
Hardware Installation
17
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Turn on attached units:
a
b
Turn on the MD1000 expansion enclosure(s). Wait for the enclosure status LED to light blue.
Turn on the MD3000i and wait for the status LED to indicate that the unit is ready:
•
•
If the status LEDs light a solid amber, the MD3000i is still coming online.
If the status LEDs are blinking amber, there is an error that can be viewed using the
MD Storage Manager.
•
If the status LEDs light a solid blue, the MD3000i is ready.
c
After the MD3000i is online and ready, turn on any attached host systems.
5
Using the MD Storage Manager, update all attached MD1000 firmware if it is out of date:
a
b
Select Support
→
Download Firmware
→
Download Environmental (EMM) Card Firmware.
Check the Select All check box so that all attached MD1000 enclosures are updated at the same
time (each takes approximately 8 minutes to update).
18
Hardware Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
Software Installation
The MD3000i Resource CD contains all documentation pertinent to MD3000i hardware and
MD Storage Manager software. It also includes software and drivers for both Linux and
®
®
Microsoft Windows operating systems.
The MD3000i Resource CD contains a readme.txt file covering changes to the software, updates,
fixes, patches, and other important data applicable to both Linux and Windows operating systems.
The readme.txt file also specifies requirements for accessing documentation, information regarding
versions of the software on the CD, and system requirements for running the software.
For more information on supported hardware and software for Dell™ PowerVault™ systems, refer to
the Dell™ PowerVault™ MD3000i Support Matrix located at support.dell.com.
Dell recommends installing all the latest updates available at support.dell.com.
Use the following procedure to assemble and start your system for the first time:
1
Install the NIC(s) in each host server that you attach to the MD3000i Storage Array, unless the
NIC was factory installed. For general information on setting up your IP addresses, see Guidelines
for Configuring Your Network for iSCSI.
2
3
Cable the storage array to the host server(s), either directly or via a switch.
Cable the Ethernet management ports on the storage array to either the management network
(iSCSI-attached host server) or dedicated management station (non-iSCSI).
4
5
Power on the storage array and wait for the status LED to turn blue.
Install the iSCSI Initiator Software (iSCSI-attached Host
To configure iSCSI later in this document (see "Array Setup and iSCSI Configuration"), you must
install the Microsoft iSCSI initiator on any host server that will access your storage array before you
install the MD Storage Manager software.
®
NOTE: Windows Server 2008 contains a built-in iSCSI initiator. If your system is running Windows
Server 2008, you do not need to install the iSCSI initiator as shown in this section. Skip directly to "Installing
MD Storage Software."
Software Installation
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Depending on whether you are using a Windows Server 2003 operating system or a Linux operating
system, refer to the following steps for downloading and installing the iSCSI initiator.
Installing the iSCSI Initiator on a Windows Host Server
1
Refer to the Dell
™
PowerVault
™
MD3000i Support Matrix on support.dell.com for the latest version
and download location of the Microsoft iSCSI Software Initiator software.
2
3
From the host server, download the iSCSI Initiator software.
Once the installation begins and the Microsoft iSCSI Initiator Installation setup panel appears, select
Initiator Service and Software Initiator
.
4
5
DO NOT select Microsoft MPIO Multitpathing Support for iSCSI
.
NOTICE: Make sure the Microsoft MPIO Multitpathing Support for iSCSI option is NOT selected. Using this option
will cause the iSCSI initiator setup to function improperly.
Accept the license agreement and finish the install.
NOTE: If you are prompted to do so, reboot your system.
Installing the iSCSI Initiator on a Linux Host Server
Follow the steps in this section to install the iSCSI initiator on a Linux server.
NOTE: All appropriate Linux iSCSI initiator patches are installed using the MD3000i Resource CD during MD
Storage Manager Software installation.
Installing the iSCSI Initiator on a RHEL 4 System
®
®
You can install the iSCSI initiator software on Red Hat Enterprise Linux 4 systems either during or
after operating system installation.
To install the iSCSI initiator during RHEL 4 installation:
1
When the Package Installation Defaults screen is displayed, select the Customize the set of Packages
to be installed option. Click Next to go to the Package Group Selection screen.
2
In the Servers list, select the Network Servers package and click Details to display a list of Network
Server applications.
3
4
Select the iscsi-initiator-utils - iSCSI daemon and utility programs option.
Click OK, then Next to continue with the installation.
To install the iSCSI initiator after RHEL 4 installation:
1
From the desktop, click Applications
Group Selection screen is displayed.
→
System Settings
→
Add Remove Applications. The Package
2
In the Servers list, select the Network Servers package and click Details to display a list of Network
Server applications.
20
Software Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
3
4
Select the iscsi-initiator-utils - iSCSI daemon and utility programs option.
Click Close, then Update
.
NOTE: Depending upon your installation method, the system will ask for the required source to install the
package.
Installing the iSCSI Initiator on a RHEL 5 System
You can install the iSCSI initiator software on Red Hat Enterprise Linux 5 systems either during or after
operating system installation. With this version of the Linux software, you can also elect to install the
iSCSI initiator after the operating system installation via the command line.
To install the iSCSI initiator during RHEL 5 installation:
1
2
3
4
5
6
When the Package Installation Defaults screen is displayed, select the Customize now option.
Click Next to go to the Package Group Selection screen.
Select Base System, then select the Base option.
Click Optional Packages
.
Select the iscsi-initiator-utils option.
Click OK, then Next to continue with the installation.
To install the iSCSI initiator after RHEL 5 installation:
1
From the desktop, select Applications
displayed.
→
Add/Remove Software. The Package Manager screen is
2
3
4
5
In the Package Manager screen, select the Search tab.
Search for iscsi-initiator-utils.
When it is displayed, select the iscsi-initiator-utils option.
Click Apply
.
NOTE: Depending upon your installation method, the system will ask for the required source to install the
package.
NOTE: This method might not work if network access is not available to a Red Hat Network repository.
To install the iSCSI initiator after RHEL 5 installation via the command line:
1
2
Insert the RHEL 5 installation CD 1 or DVD. If your media is not automounted, you must manual
mount it. The iscsi-initiatorutils.rpm file is located in the Server or Client subdirectory.
Run the following command:
rpm -i /path/to/media/Server/iscsi-initiatorutils.rpm
Software Installation
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the iSCSI Initiator on a SLES 9 System
®
You can install the iSCSI initiator software on SUSE Linux Enterprise Servers (SLES) 9 SP3 systems
either during or after operating system installation.
To install the iSCSI initiator during SLES 9 installation:
1
2
3
4
At the YaST Installation Settings screen, click Change
Click Software, then select Detailed Selection to see a complete list of packages.
Select Various Linux Tools, then select linux-iscsi
Click Accept
If a dependencies window is displayed, click Continue and proceed with the installation.
.
.
.
To install the iSCSI initiator after SLES 9 installation:
1
2
3
4
5
6
From the Start menu, select System YaST
.
Select Software, then Install and Remove Software
.
In the Search box, enter linux-iscsi.
When the linux-iscsi module is displayed, select it.
Click on Check Dependencies to determine if any dependencies exist.
If no dependencies are found, click Accept
.
Installing the iSCSI Initiator on a SLES 10 SP1 System
You can install the iSCSI initiator software on SUSE Linux Enterprise Server Version 10 systems either
during or after operating system installation.
To install the iSCSI initiator during SLES 10 SP1 installation:
1
2
3
4
5
6
At the YaST Installation Settings screen, click Change.
Click Software, then select Search
In the Search box, enter iscsi.
.
When the open-iscsi and yast2-iscsi-client modules are displayed, select them.
Click Accept
If a dialog box regarding dependencies appears, click Continue and proceed with installation.
.
Installing the iSCSI initiator after SLES 10 SP1 installation:
1
2
3
Select Desktop
Select Search
→
YaST
→
Software
→
Software Management.
.
In the Search box, enter iscsi.
22
Software Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
4
5
When the open-iscsi and yast2-iscsi-client modules are displayed, select them.
Click Accept
.
Installing MD Storage Software
The MD3000i Storage Software provides the host-based storage agent, multipath driver, and MD
Storage Manager application used to operate and manage the storage array solution. The MD Storage
Manager application is installed on a host server to configure, manage, and monitor the storage array.
When installing from the CD, three installation types are available:
•
•
•
Typical (Full installation) — This package installs both the management station and host server
software. It includes the necessary host-based storage agent, multipath driver, and MD Storage
Manager software. Select this option if you plan to use MD Storage Manager on the host server to
configure, manage, and monitor the storage array.
Management Station
—
This package installs the MD Storage Manager software, which is needed
to configure, manage, and monitor the storage array. Select this option if you plan to us MD Storage
Manager to manage the storage array from a standalone system that is connected to the storage
array only via the Ethernet management ports.
Host — This package installs the necessary storage agent and multipath driver on a host server
connected to the storage array. Select this option on all host servers that are connected to a storage
array but will NOT use MD Storage Manager for any storage array management tasks.
NOTE: Dell recommends using the Host installation type if the host server is running Windows Server 2008
Core version.
Installing MD Storage Software on an iSCSI-attached Host Server (Windows)
To install MD Storage Manager on a Windows system, you must have administrative privileges to install
MD Storage Manager files and program packages to the C:\Program Files\Dell\MD Storage Manager
directory.
NOTE: A minimum version of the Storport driver must be installed on the host server before installing the MD
Storage Manager software. A hotfix with the minimum supported version of the Storport driver is located in the
\windows\Windows_2003_2008\hotfixes directory on the MD3000i Resource CD. The MD Storage Manager
installation will test for the minimum Storport version and will require you to install it before proceeding.
Complete the following steps to install MD Storage Manager on an iSCSI-connected host server:
1
2
Close all other programs before installing any new software.
Insert the CD, if necessary, and navigate to the main menu.
NOTE: If the host server is running Windows Server 2008 Core version, navigate to the CD drive and run the
setup.bat utility.
3
From the main menu, select Install MD3000i Storage Software.
The Installation Wizard appears.
Software Installation
23
Download from Www.Somanuals.com. All Manuals Search And Download.
4
5
Click Next.
Accept the terms of the License Agreement, and click Next
.
The screen shows the default installation path.
6
7
Click Next to accept the path, or enter a new path and click Next.
Select an installation type:
•
Typical (Full installation) — This package installs both the management station and host software.
It includes the necessary host-based storage agent, multipath driver, and MD Storage Manager
software. Select this option if you plan to use MD Storage Manager on the host server to configure,
manage, and monitor the storage array.
OR
•
Host — This package installs the necessary storage agent and multipath driver on a host server
connected to the storage array. Select this option on all hosts that are connected to a storage array
but will NOT use MD Storage Manager for any storage array management tasks.
NOTE: Dell recommends using the Host installation type if the host server is running Windows Server 2008
Core version.
8
9
Click Next.
If the Overwrite Warning dialog appears, click OK. The software currently being installed
automatically replaces any existing versions of MD Storage Manager.
10 If you selected Typical (full) installation in step 6, a screen appears asking whether to restart the event
monitor automatically or manually after rebooting. You should configure only one system (either a host
or a management station) to automatically restart the event monitor.
NOTE: The event monitor notifies the administrator of problem conditions with the storage array. MD Storage
Manager can be installed on more than one system, but running the event monitor on multiple systems can
cause multiple alert notifications to be sent for the same error condition. To avoid this issue, enable the event
monitor only on a single system that monitors your storage arrays. For more information on alerts, the event
monitor, and manually restarting the event monitor, see the User’s Guide.
11 The Pre-Installation Summary screen appears, showing the installation destination, the required disk
space, and the available disk space. If the installation path is correct, click Install
.
12 When the installation completes, click Done.
13 A screen appears asking if you want to restart the system now. Select No, I will restart my
system myself.
14 If you are setting up a cluster host, double-click the MD3000i Stand Alone to Cluster.reg file located
in the windows\utility directory of the MD3000i Resource CD. This merges the file into the registry of
each node.
NOTE: Windows clustering is only supported on Windows Server 2003 and Windows Server 2008.
24
Software Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are reconfiguring a cluster node into a stand alone host, double-click the MD3000i Cluster to
Stand Alone.reg file located in the windows\utility directory of the MD3000i Resource CD. This
merges the file into the host registry.
NOTE: These registry files set the host up for the correct failback operation.
15 If you have third-party applications that use the Microsoft Volume Shadow-copy Service (VSS) or Virtual
Disk Service (VDS) Application Programming Interface (API), install the VDS_VSS package located in
the windows\VDS_VSS directory on the MD3000i Resource CD. Separate versions for 32-bit and 64-bit
operating systems are provided. The VSS and VDS provider will engage only if it is needed.
16 Set the path for the command line interface (CLI), if required. See the MD Storage Manager CLI Guide
for more information.
17 Install MD Storage Manager on all other Windows hosts attached to the MD3000i array.
18 If you have not yet cabled your MD3000i Storage Array, do so at this time.
19 After the MD3000i has initialized, reboot each host attached to the array.
NOTE: If you are not installing MD Storage Manager directly from the Resource CD (for example, if you are instead
installing MD Storage Manager from a shared network drive), you must manually apply iSCSI updates to the
Windows system registry. To apply these updates, go to the \windows\Windows_2003_2008\iSCSI_reg_changer
directory on the Resource CD and run the iSCSi_reg_changer_Win2k3.bat or iSCSi_reg_changer_Win2k8.bat file.
The iSCSI Initiator must be installed before you make these updates.
Installing MD Storage Software on an iSCSI-attached Host Server (Linux)
MD Storage Manager can be installed and used only on Linux distributions that utilize the RPM Package
®
®
Manager format, such as Red Hat or SUSE . The installation packages are installed by default in the
/opt/dell/mdstoragemanager directory.
NOTE: Root privileges are required to install the software.
Follow these steps to install MD Storage Manager software on an iSCSI-connected host server:
1
2
Close all other programs before installing any new software.
Insert the CD. For some Linux installations, when you insert a CD into a drive, a screen appears asking
if you want to run the CD. Select Yes if the screen appears. Otherwise, double-click on the autorun
script in the top directory or, from within a terminal window, run ./install.sh from the linux directory
on the CD.
NOTE: On RHEL 5 operating systems, CDs are automounted with the -noexec mount option. This option does
not allow you to run any executable directly from the CD. To complete this step, you must unmount the CD,
then manually remount it. Then, you can run these executables. The command to unmount the CD-ROM is:
umount CD_device_node
The command to manually mount CD is:
mount CD_device_node mount_directory
Software Installation
25
Download from Www.Somanuals.com. All Manuals Search And Download.
3
At the CD main menu, type
The installation wizard appears.
Click Next
2
and press Enter
.
4
5
6
.
Accept the terms of the License Agreement and click Next
.
Select an installation type:
•
Typical (Full installation) — This package installs both the management station and host options.
It includes the necessary host-based storage agent, multipath driver, and MD Storage Manager
software. Select this option if you plan to use MD Storage Manager on the host server to configure,
manage, and monitor the storage array.
OR
•
Host — This package installs the necessary storage agent and multipath driver on a host server
connected to the storage array. Select this option on all hosts that are connected to a storage array
but will NOT use MD Storage Manager for any storage array management tasks.
7
8
If the Overwrite Warning dialog appears, click OK. The software currently being installed
automatically replaces any existing versions of MD Storage Manager.
9
The Multipath Warning dialog box may appear to advise that this installation requires an RDAC MPP
driver. If this screen appears, click OK. Installation instructions for the RDAC MPP driver are given in
step 13.
10 If you selected Typical (full) installation in step 6, a screen appears asking whether to restart the event
monitor automatically or manually after rebooting. You should configure only one system (either a host
or a management station) to automatically restart the event monitor.
NOTE: The event monitor notifies the administrator of problem conditions with the storage array. MD Storage
Manager can be installed on more than one system, but running the event monitor on multiple systems can
cause multiple alert notifications to be sent for the same error condition. To avoid this issue, enable the event
monitor only on a single system which monitors your MD3000i arrays. For more information on alerts, the
event monitor, and manually restarting the event monitor, see the User’s Guide.
11 The Pre-Installation Summary screen appears showing the installation destination, the required disk
space, and the available disk space. If the installation path is correct, click Install
.
12 When the installation completes, click Done.
13 At the install the multi-pathing driver [y/n]?prompt, answer
y
(yes).
14 When the RDAC driver installation is complete, quit the menu and restart the system.
15 Install MD Storage Manager on all other hosts attached to the MD3000i array.
16 Reboot each host attached to the array.
26
Software Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a Dedicated Management Station (Windows and Linux)
Optionally, you can manage your storage array over the network via a dedicated system attached to the
array via the Ethernet management port. If you choose this option, follow these steps to install MD
Storage Manager on that dedicated system.
1
2
(Windows) From the CD main menu, select Install MD3000i Storage Software.
(Linux) From the CD main menu, type
The Installation Wizard appears.
2
and press <Enter>.
3
4
5
6
Click Next
.
Accept the terms of the License Agreement and click Next
.
Click Next to accept the default installation path (Windows), or enter a new path and click Next
.
Select Management Station as the installation type. This option installs only the MD Storage
Manager software used to configure, manage and monitor a MD3000i storage array.
7
8
Click Next.
If the Overwrite Warning dialog appears, click OK. The software currently being installed
automatically replaces any existing versions of MD Storage Manager.
9
A screen appears asking whether to restart the event monitor automatically or manually after
rebooting. You should configure only one system (either a host or a management station) to
automatically restart the event monitor.
NOTE: The event monitor notifies the administrator of problem conditions with the storage array. MD Storage
Manager can be installed on more than one system, but running the event monitor on multiple systems can
cause multiple alert notifications to be sent for the same error condition. To avoid this issue, enable the event
monitor only on a single system that monitors your MD3000i arrays. For more information on alerts, the event
monitor, and manually restarting the event monitor, see the MD Storage Manager User’s Guide.
10 The Pre-Installation Summary screen appears showing the installation destination, the required disk
space, and the available disk space. If the installation path is correct, click Install
.
11 When the installation completes, click Done.
A screen appears asking if you want to restart the system now.
12 Restart the system.
13 Set the path for the command line interface (CLI), if required. See the MD Storage Manager CLI
Guide for more information.
Software Installation
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Documentation for Windows Systems
Viewing Resource CD Contents
1
Insert the CD. If autorun is disabled, navigate to the CD and double-click setup.exe.
NOTE: On a server running Windows Server 2008 Core version, navigate to the CD and run the setup.bat
utility. Only the MD3000i Readme can be viewed on Windows Server 2008 Core versions. Other MD3000i
documentation cannot be viewed or installed.
A screen appears showing the following items:
a
b
c
d
View MD3000i Readme
Install MD3000i Storage Software
Install MD3000i Documentation
iSCSI Setup Instructions
2
To view the readme.txt file, click the first bar.
The readme.txt file appears in a separate window.
3
4
Close the window after viewing the file to return to the menu screen.
To view the manuals from the CD, open the HTML versions from the /docs/ folder on the CD.
Installing the Manuals
1
Insert the CD, if necessary, and select Install MD3000i Documentation in the main menu.
A second screen appears.
2
3
4
5
Click Next
Accept the License Agreement and click Next
Select the installation location or accept the default and click Next
Click Install
The installation process begins.
.
.
.
.
6
7
When the process completes, click Finish to return to the main menu.
To view the installed documents, go to My Computer and navigate to the installation location.
NOTE: The MD3000i Documentation cannot be installed on Windows Server 2008 Core versions.
28
Software Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
Documentation for Linux Systems
Viewing Resource CD Contents
1
Insert the CD.
For some Linux distributions, a screen appears asking if you want to run the CD. Select Yes if the
screen appears. If no screen appears, execute ./install.sh within the linux folder on the CD.
2
A menu screen appears showing the following items:
1 View MD3000i Readme
2 Install MD3000i Storage Software
3 Install Multi-pathing Driver
4 Install MD3000i Documentation
5 View MD3000i Documentation
6 iSCSI Setup Instructions
7 Dell Support
8 View End User License Agreement
3
4
If you want to view the readme.txt file, type
The file appears in a separate window. Close the window after viewing the file to return to the menu screen.
To view another document, type and press <Enter>.
1
and press <Enter>.
5
A second menu screen appears with the following selections:
MD3000i Owner's Manual
MD3000i Installation Guide
MD Storage Manager CLI Guide
MD Storage Manager User's Guide
NOTE: To view the documents from the CD, you must have a web browser installed on the system.
Type the number of the document you want and press <Enter>.
The document opens in a browser window.
5
6
7
Close the document when you are finished. The system returns to the documentation menu described
in step 4.
Select another document or type
menu screen.
q
and press <Enter> to quit. The system returns to the main
Software Installation
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Manuals
1
2
Insert the CD, if necessary, and from the menu screen, type
5
and press <Enter>.
A screen appears showing the default location for installation. Press <Enter> to accept the path
shown, or enter a different path and press <Enter>.
3
4
When installation is complete, press any key to return to the main menu.
To view the installed documents, open a browser window and navigate to the installation directory.
30
Software Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
To use the storage array, you must configure iSCSI on both the host server(s) and the storage array.
Step-by-step instructions for configuring iSCSI are described in this section. However, before
proceeding here, you must have already installed the Microsoft iSCSI initiator and the MD Storage
Manager software. If you have not, refer to Software Installation and complete those procedures
before attempting to configure iSCSI.
from a management station, the iSCSI initiator must be installed and configured on each host server.
Before You Start
Before you begin configuring iSCSI, you should fill out the iSCSI Configuration Worksheet
(Table 4-2 and Table 4-3). Gathering this type of information about your network prior to starting
the configuration steps should help you complete the process in less time.
NOTE: If you are running Windows Server 2008 and elect to use IPv6, use Table 4-3 to define your
settings on the host server and storage array controller iSCSI ports. IPv6 is not supported on storage
array controller management ports.
Terminology
The table below outlines the terminology used in the iSCSI configuration steps later in this section.
Term
Definition
CHAP (Challenge Handshake
An optional security protocol used to control access to an iSCSI
storage system by restricting use of the iSCSI data ports on both
the host server and storage array. For more information on the
types of CHAP authentication supported, see Understanding
CHAP Authentication.
Authentication Protocol)
host or host server
host server port
A server connected to the storage array via iSCSI ports.
iSCSI port on the host server used to connect it to the storage
array.
iSCSI initiator
The iSCSI-specific software installed on the host server that
controls communications between the host server and the storage
array.
Setting Up Your iSCSI Storage Array
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 4-1. Standard Terminology Used in iSCSI Configuration (continued)
Term
Definition
iSCSI host port
The iSCSI port (two per controller) on the storage array.
iSNS (Microsoft Internet Storage An automated discovery, management and configuration tool
Naming Service)
used by some iSCSI devices.
management station
The system from which you manage your host server/storage array
configuration.
storage array
target
server.
An iSCSI port on the storage array that accepts and responds to
requests from the iSCSI initiator installed on the host server.
iSCSI Configuration Worksheet
The iSCSI Configuration Worksheet (Table 4-2 or Table 4-3) helps you plan your configuration.
Recording host server and storage array IP addresses at a single location will help you configure your
setup faster and more efficiently.
Guidelines for Configuring Your Network for iSCSI provides general network setup guidelines for both
Windows and Linux environments. It is recommended that you review these guidelines before
completing the worksheet.
32
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 4-2. iSCSI Configuration Worksheet (IPv4 settings)
host server
A
Mutual CHAP
Secret
cntl. 0
cntl. 1
MD3000i
B
192.168.128.102
(Mgmt network port)
Target CHAP
Secret
192.168.130.101 (In 0 default)
192.168.131.101 (In 1 default)
192.168.131.102 (In 1 default)
192.168.130.102 (In 0 default)
192.168.128.101 (Mgmt network port)
If you need additional space for more than one host server, use an additional sheet.
Subnet
(should be different for each NIC)
A
Default gateway
Static IP address (host server)
iSCSI port 1
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
iSCSI port 2
iSCSI port 3
iSCSI port 4
Management port
Management port
B
Static IP address (storage array)
Subnet
Default gateway
____ . ____ . ____ . ____
iSCSI controller 0, In 0
iSCSI controller 0, In 1
Management port, cntrl. 0
iSCSI controller 1, In 0
iSCSI controller 1, In 1
Management port, cntrl. 1
____ . ____ . ____ . ____ ____ . ____ . ____ . ____
____ . ____ . ____ . ____ ____ . ____ . ____ . ____
____ . ____ . ____ . ____ ____ . ____ . ____ . ____
____ . ____ . ____ . ____ ____ . ____ . ____ . ____
____ . ____ . ____ . ____ ____ . ____ . ____ . ____
____ . ____ . ____ . ____ ____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
____ . ____ . ____ . ____
Setting Up Your iSCSI Storage Array
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 4-3. iSCSI Configuration Worksheet (IPv6 settings)
host server
A
B
Mutual CHAP
Secret
cntl. 0
cntl. 1
MD3000i
Target CHAP
Secret
If you need additional space for more than one host server, use an additional sheet.
Host iSCSI port 2
Host iSCSI port 1
A
________________________
Link Local IP Address
Routable IP Address
Subnet Prefix
Link Local IP Address
Routable IP Address
Subnet Prefix
________________________
________________________
________________________
________________________
________________________
________________________
________________________
Gateway
Gateway
iSCSI controller 0, In 0
IP Address
B
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
Routable IP Address 1
Routable IP Address 2
Router IP Address
iSCSI controller 0, In 1
IP Address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
Routable IP Address 1
Routable IP Address 2
Router IP Address
iSCSI controller 1, In 0
IP Address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
Routable IP Address 1
Routable IP Address 2
Router IP Address
iSCSI controller 1, In 1
IP Address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
Routable IP Address 1
Routable IP Address 2
Router IP Address
34
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring iSCSI on Your Storage Array
The following sections contains step-by-step instructions for configuring iSCSI on your storage array.
However, before beginning, it is important to understand where each of these steps occur in relation to
your host server/storage array environment.
Table 4-4 below shows each specific iSCSI configuration step and where it occurs.
Table 4-4. Host Server vs. Storage Array
This step is performed on the HOST SERVER using
the Microsoft or Linux iSCSI Initiator:
This step is performed on the STORAGE ARRAY
using MD Storage Manager:
Step 1: Discover the storage array
Step 2: Configure the iSCSI ports on the storage
array
Step 3: Perform target discovery from the iSCSI
initiator
Step 4: Configure host access
Step 5: (Optional) Configure CHAP
authentication on the storage array
Step 6: (Optional) Configure CHAP
authentication on the host server
Step 7: Connect to the storage array from the host
server
Step 8: (Optional) Set up in-band management
Using iSNS
iSNS (Internet Storage Naming Service) Server, supported only on Windows iSCSI environments,
eliminates the need to manually configure each individual storage array with a specific list of initiators
and target IP addresses. Instead, iSNS automatically discovers, manages, and configures all iSCSI devices
in your environment.
For more information on iSNS, including installation and configuration, see www.microsoft.com.
Setting Up Your iSCSI Storage Array
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 1: Discover the Storage Array (Out-of-band management only)
Default Management Port Settings
By default, the storage array management ports will be set to DHCP configuration. If the controller(s) on
your storage array is unable to get IP configuration from a DHCP server, it will timeout after ten seconds
and fall back to a default static IP address. The default IP configuration is:
Controller 0: IP: 192.168.128.101 Subnet Mask: 255.255.255.0
Controller 1: IP: 192.168.128.102 Subnet Mask: 255.255.255.0
NOTE: No default gateway is set.
NOTE: If DHCP is not used, initial configuration of the management station must be performed on the same
physical subnet as the storage array. Additionally, during initial configuration, at least one network adapter
must be configured on the same IP subnet as the storage array’s default management port (192.168.128.101 or
192.168.128.102). After initial configuration (management ports are configured using MD Storage Manager),
the management station’s IP address can be changed back to its previous settings.
NOTE: This procedure applies to out-of-band management only. If you choose to set up in-band
management, you must complete this step and then refer to Step 8: (Optional) Set Up In-Band Management.
You can discover the storage array automatically or manually. Choose one and complete the steps below.
Automatic Storage Array Discovery
1
Launch MD Storage Manager.
If this is the first storage array to be set up, the Add New Storage Array window appears.
2
Choose Automatic and click OK
.
It may take several minutes for the discovery process to complete. Closing the discovery status window
before the discovery process completes will cancel the discovery process.
After discovery is complete, a confirmation screen appears. Click Close to close the screen.
Manual Storage Array Discovery
1
Launch MD Storage Manager.
If this is the first storage array to be set up, the Add New Storage Array window appears.
2
3
Select Manual and click OK.
Select Out-of-band management and enter the host server name(s) or IP address(es) of the iSCSI
storage array controller.
4
Click Add.
Out-of-band management should now be successfully configured.
After discovery is complete, a confirmation screen appears. Click Close to close the screen.
36
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Array
1
2
3
in MD Storage Manager.
Click the Initial Setup Tasks option to see links to the remaining post-installation tasks. For more
information about each task, see the User’s Guide. Perform these tasks in the order shown in Table 4-5.
NOTE: Before configuring the storage array, check the status icons on the Summary tab to make sure the
enclosures in the storage array are in an Optimal status. For more information on the status icons,
see Troubleshooting Tools.
Table 4-5. Initial Storage Array Setup Tasks
Task
Purpose
Information Needed
Rename the storage array.
To provide more a meaningful
name than the software-assigned
label of Unnamed.
A unique, clear name with no more
than 30 characters that may include
letters, numbers, and no special
characters other than underscore (_),
minus (–), or pound sign (#).
NOTE: If you need to physically
find the device, click Blink the
storage array on the Initial Setup
Tasks dialog box or click the Tools
tab and choose Blink. Lights on the
front of the storage array blink
intermittently to identify the array.
Dell recommends blinking storage
arrays to ensure that you are
NOTE: MD Storage Manager does not
check for duplicate names. Names are
not case sensitive.
working on the correct enclosure.
Set a storage array password.
To restrict unauthorized access,
MD Storage Manager asks for a
password before changing the
configuration or performing a
destructive operation.
A case-sensitive password that meets
the security requirements of your
enterprise.
Setting Up Your iSCSI Storage Array
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 4-5. Initial Storage Array Setup Tasks (continued)
Task
Purpose
Information Needed
Set the management port IP
addresses on each controller.
To set the management port IP
addresses to match your public
network configuration. Although
DHCP is supported, static IP
addressing is recommended.
In MD Storage Manager, select
Initial Setup Tasks→ Configure
Ethernet Management Ports, then
specify the IP configuration for each
management port on the storage
array controllers.
NOTE: If you change a management
port IP address, you may need to
update your management station
configuration and/or repeat storage
array discovery.
Set up alert notifications.
Set up e-mail alerts.
To arrange to notify individuals (by E-mail — Sender (sender’s SMTP
e-mail) and/or storage management gateway and e-mail address) and
stations (by SNMP) when a storage recipients (fully qualified e-mail
array component degrades or fails, addresses)
Set up SNMP alerts.
or an adverse environmental
SNMP — (1) A community name, a
NOTE: The Status area in the
Summary tab shows if alerts have
been set for the selected array.
condition occurs.
known set of storage management
stations set by administrator as an
ASCII string in the management
console (default: "public"), and (2)
a trap destination, IP address or host
name of a management console
running an SNMP service
38
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 2: Configure the iSCSI Ports on the Storage Array
By default, the iSCSI ports on the storage array are set to the following IPv4 settings:
Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask: 255.255.255.0 Port: 3260
Controller 0, Port 1: IP: 192.168.131.101 Subnet Mask: 255.255.255.0 Port: 3260
Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask: 255.255.255.0 Port: 3260
Controller 1, Port 1: IP: 192.168.131.102 Subnet Mask: 255.255.255.0 Port: 3260
NOTE: No default gateway is set.
To configure the iSCSI ports on the storage array, complete the following steps:
1
2
From MD Storage Manager, click the iSCSI tab, then select Configure iSCSI Host Ports
Configure the iSCSI ports on the storage array.
.
NOTE: Using static IPv4 addressing is recommended, although DHCP is supported.
NOTE: IPv4 is enabled by default on the iSCSI ports. You must enable IPv6 to configure IPv6 addresses.
NOTE: IPv6 is supported only on controllers that will connect to host servers running Windows Server 2008.
The following settings are available (depending on your specific configuration) by clicking the
Advanced button:
•
Virtual LAN (VLAN) support
A VLAN is a network of different systems that behave as if they are connected to the same
segments of a local area network (LAN) and are supported by the same switches and routers.
When configured as a VLAN, a device can be moved to another location without being
reconfigured. To use VLAN on your storage array, obtain the VLAN ID from your network
administrator and enter it here.
•
•
Ethernet priority
This parameter is set to determine a network access priority.
TCP listening port
The port number the controller on the storage array uses to listen for iSCSI logins from host server
iSCSI initiators.
NOTE: The TCP listening port for the iSNS server is the port number the storage array controller uses to
connect to an iSNS server. This allows the iSNS server to register the iSCSI target and portals of the storage
array so that the host server initiators can identify them.
•
Jumbo frames
Jumbo Ethernet frames are created when the maximum transmission units (MTUs) are larger than
1500 bytes per frame. This setting is adjustable port-by-port.
3
4
5
To enable ICMP PING responses for all ports, select Enable ICMP PING responses
Click OK when all iSCSI storage array port configurations are complete.
.
Test the connection by performing a ping command on each iSCSI storage array port.
Setting Up Your iSCSI Storage Array
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 3: Perform Target Discovery from the iSCSI Initiator
This step identifies the iSCSI ports on the storage array to the host server. Select the set of steps in one
of the following sections (Windows or Linux) that corresponds to your operating system.
If you are using Windows Server 2003 or Windows Server 2008 GUI version
1
Click Start
→
Tools iSCSI Initiator
Programs
→
Microsoft iSCSI Initiator or Start
→
All Programs
→
Administrative
→
.
2
3
Click the Discovery tab.
Under Target Portals, click Add and enter the IP address or DNS name of the iSCSI port on the
storage array.
4
5
If the iSCSI storage array uses a custom TCP port, change the Port number. The default is 3260.
Click Advanced and set the following values on the General tab:
•
•
•
Local Adapter: Must be set to Microsoft iSCSI Initiator.
Source IP: The source IP address of the host you want to connect with.
Data Digest and Header Digest: Optionally, you can specify that a digest of data or header
information be compiled during transmission to assist in troubleshooting.
•
CHAP logon information: Leave this option unselected and do not enter CHAP information
at this point, unless you are adding the storage array to a SAN that has target CHAP already
configured.
NOTE: IPSec is not supported.
Click OK to exit the Advanced menu, and OK again to exit the Add Target Portals screen.
6
To exit the Discovery tab, click OK.
If you plan to configure CHAP authentication, do not perform discovery on more than one iSCSI
port at this point. Stop here and go to the next step, Step 4: Configure Host Access.
If you do not plan to configure CHAP authentication, repeat step 1 thorough step 6 (above) for all
iSCSI ports on the storage array.
If you are using Windows Server 2008 Core Version
1
2
3
Set the iSCSI initiator service to start automatically:
sc \\<server_name> config msiscsi start= auto
Start the iSCSI service:
sc start msiscsi
Add a target portal:
iscsicli QAddTargetPortal <IP_address_of_iSCSI_port_on_storage
array>
40
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are using Linux Server
®
®
®
Configuration of the iSCSI initiator for Red Hat Enterprise Linux version 4 and SUSE Linux
Enterprise Server 9 distributions is performed by modifying the /etc/iscsi.conf file, which is installed by
default when you install MD Storage Manager. You can edit the file directly, or replace the default file
with a sample file included on the MD3000i Resource CD.
To use the sample file included on the CD:
1
2
3
4
Save the default /etc/iscsi.conf file by naming it to another name of your choice.
Copy the appropriate sample file from /linux/etc on the CD to /etc/iscsi.conf
Rename the sample file to iscsi.conf
.
.
Edit the iscsi.conf file and replace the IP address entries shown for DiscoveryAddress=with the
IP addresses assigned to the iSCSI ports on your storage array:
For example, if your MD3000i has two iSCSI controllers (four iSCSI ports), you will need to add four
IP addresses:
DiscoveryAddress=<your_storage_array_IP_address>
DiscoveryAddress=<your_storage_array_IP_address>
DiscoveryAddress=<your_storage_array_IP_address>
DiscoveryAddress=<your_storage_array_IP_address>
If you elect not to use the sample file on the CD, edit the existing default /etc/iscsi.conf file as shown
in the previous example.
5
Edit (or add) the following entries to the /etc/iscsi.conf file:
HeaderDigest=never
DataDigest=never
LoginTimeout=15
IdleTimeout=15
PingTimeout=5
ConnFailTimeout=144
AbortTimeout=10
ResetTimeout=30
Continuous=no
InitialR2T=no
ImmediateData=yes
MaxRecvDataSegmentLength=65536
Setting Up Your iSCSI Storage Array
41
Download from Www.Somanuals.com. All Manuals Search And Download.
FirstBurstLength=262144
MaxBurstLength=16776192
6
7
Restart the iSCSI daemon by executing the following command from the console:
/etc/init.d/iscsi restart
Verify that the server can connect to the storage array by executing this command from a console:
iscsi -ls
If successful, an iSCSI session has been established to each iSCSI port on the storage array. Sample
output from the command should look similar to this:
********************************************************************
SFNet iSCSI Driver Version ...4:0.1.11-3(02-May-2006)
********************************************************************
TARGET NAME
TARGET ALIAS
HOST ID
: iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
:
: 2
BUS ID
: 0
TARGET ID
: 0
TARGET ADDRESS
SESSION STATUS
SESSION ID
: 192.168.0.110:3260,1
: ESTABLISHED AT Wed May 9 18:20:27 CDT 2007
: ISID 00023d000001 TSIH 5
********************************************************************
TARGET NAME
TARGET ALIAS
HOST ID
: iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
:
: 3
BUS ID
: 0
TARGET ID
: 0
TARGET ADDRESS
SESSION STATUS
SESSION ID
: 192.168.0.111:3260,1
: ESTABLISHED AT Wed May 9 18:20:28 CDT 2007
: ISID 00023d000002 TSIH 4
If you are using RHEL 5 or SLES 10 SP1
Configuration of the iSCSI initiator for RHEL version 5 and SLES 10 SP1 distributions is done by
modifying the /etc/iscsi/iscsid.conf file, which is installed by default when you install MD Storage
Manager. You can edit the file directly, or replace the default file with a sample file included on the
MD3000i Resource CD.
To use the sample file included on the CD:
1
2
3
Save the default /etc/iscsi/iscsid.conf file by naming it to another name of your choice.
Copy the appropriate sample file from /linux/etc on the CD to /etc/iscsi/iscsid.conf
.
Rename the sample file to iscsid.conf
.
42
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Edit the following entries in the /etc/iscsi/iscsid.conf file:
a
b
Edit (or verify) that the node.startup = manual line is disabled.
Edit (or verify) that the node.startup = automaticline is enabled. This will enable
automatic startup of the service at boot time.
c
Verify that the following time-out value is set to 144:
node.session.timeo.replacement_timeout = 144
d
Save and close the /etc/iscsi/iscsid.conf file.
5
6
7
8
From the console, restart the iSCSI service with the following command:
service iscsi start
Verify that the iSCSI service is running during boot using the following command from the console:
chkconfig iscsi on
To display the available iscsi targets at the specified IP address, use the following command:
iscsiadm –m discovery –t st -p <IP_address_of_iSCSI_port>
After target discovery, use the following command to manually login:
iscsiadm -m node –l
This logon will be performed automatically at startup if automatic startup is enabled.
9
Manually log out of the session using the following command:
iscsiadm -m node -T <initiator_username> -p <target_ip> -u
Setting Up Your iSCSI Storage Array
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 4: Configure Host Access
This step specifies which host servers will access virtual disks on the storage array. You should perform
this step:
•
•
before mapping virtual disks to host servers
any time you connect new host servers to the storage array
1
2
3
Launch MD Storage Manager.
Click on the Configure tab, then select Configure Host Access (Manual)
.
At Enter host name, enter the host server to be available to the storage array for virtual disk mapping.
This can be an informal name, not necessarily a name used to identify the host server to the network.
4
5
In the Select host type drop-down menu, select the host type.
Click Next
.
If your iSCSI initiator shows up in the list of Known iSCSI initiators, make sure it is highlighted and
click Add and then Next. Otherwise, click New and enter the iSCSI initiator name
.
–
In Windows, the iSCSI initiator name can be found on the General tab of the iSCSI Initiator
Properties window.
–
In Linux, the iSCSI initiator name can be found in the etc/initiatorname.iscsi file or by using the
iscsi-iname command.
Click Next
.
6
7
Choose whether or not the host server will be part of a host server group that will share access to the
same virtual disks as other host servers. Select Yes only if the host is part of a Microsoft cluster.
Click Next
.
Click Finish
.
44
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Understanding CHAP Authentication
Before proceeding to either Step 5: Configure CHAP Authentication on the Storage Array (optional) or
Step 6: Configure CHAP Authentication on the Host Server (optional), it would be useful to gain an
overview of how CHAP authentication works.
What is CHAP?
Challenge Handshake Authentication Protocol (CHAP) is an optional iSCSI authentication method
where the storage array (target) authenticates iSCSI initiators on the host server. Two types of CHAP are
supported: target CHAP and mutual CHAP.
Target CHAP
In target CHAP, the storage array authenticates all requests for access issued by the iSCSI initiator(s) on
the host server via a CHAP secret. To set up target CHAP authentication, you enter a CHAP secret on
the storage array, then configure each iSCSI initiator on the host server to send that secret each time it
attempts to access the storage array.
Mutual CHAP
In addition to setting up target CHAP, you can set up mutual CHAP in which both the storage array and
the iSCSI initiator authenticate each other. To set up mutual CHAP, you configure the iSCSI initiator
with a CHAP secret that the storage array must send to the host sever in order to establish a connection.
In this two-way authentication process, both the host server and the storage array are sending
information that the other must validate before a connection is allowed.
CHAP is an optional feature and is not required to use iSCSI. However, if you do not configure CHAP
authentication, any host server connected to the same IP network as the storage array can read from and
write to the storage array.
NOTE: If you elect to use CHAP authentication, you should configure it on both the storage array (using MD
Storage Manager) and the host server (using the iSCSI initiator) before preparing virtual disks to receive data.
If you prepare disks to receive data before you configure CHAP authentication, you will lose visibility to the
disks once CHAP is configured.
Setting Up Your iSCSI Storage Array
45
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAP Definitions
To summarize the differences between target CHAP and mutual CHAP authentication, see Table 4-6.
Table 4-6. CHAP Types Defined
CHAP Type
Description
Target CHAP
Sets up accounts that iSCSI initiators use to connect to the target
storage array. The target storage array then authenticates the iSCSI
initiator.
that a target storage array uses to connect to an iSCSI initiator. The
iSCSI initiator then authenticates the target.
How CHAP Is Set Up
The next two steps in your iSCSI configuration, Step 5: Configure CHAP Authentication on the Storage
Array (optional) and Step 6: Configure CHAP Authentication on the Host Server (optional), offer step-by-
step procedures for setting up CHAP on your storage array and host server.
46
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are configuring CHAP authentication of any kind (either target-only or target and mutual), you
must complete this step and Step 6: Configure CHAP Authentication on the Host Server (optional).
If you are not configuring any type of CHAP, skip these steps and go to Step 7: Connect to the Target
Storage Array from the Host Server.
NOTE: If you choose to configure mutual CHAP authentication, you must first configure target CHAP.
Remember, in terms of iSCSI configuration, the term target always refers to the storage array.
Configuring Target CHAP Authentication on the Storage Array
1
From MD Storage Manager, click the iSCSI tab, then Change Target Authentication.
Make a selection based on the following:
Table 4-7. CHAP Settings
Selection
Description
None
This is the default selection. If None is the only selection, the storage array will
allow an iSCSI initiator to log on without supplying any type of CHAP
authentication.
None and
CHAP
The storage array will allow an iSCSI initiator to log on with or without CHAP
authentication.
CHAP
If CHAP is selected and None is deselected, the storage array will require CHAP
authentication before allowing access.
2
3
To configure a CHAP secret, select CHAP and select CHAP Secret.
Enter the Target CHAP secret (or Generate Random Secret), confirm it in Confirm Target CHAP
Secret and click OK
.
Although the storage array allows sizes from 12 to 57 characters, many initiators only support CHAP
secret sizes up to 16 characters (128-bit).
NOTE: Once entered, a CHAP secret is not retrievable. Make sure you record the secret in an accessible
place. If Generate Random Secret is used, copy and past the secret into a text file for future reference since
the same CHAP secret will be used to authenticate any new host servers you may add to the storage array. If
you forget this CHAP secret, you must disconnect all existing hosts attached to the storage array and repeat
the steps in this chapter to re-add them.
4
Click OK.
Setting Up Your iSCSI Storage Array
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Mutual CHAP Authentication on the Storage Array
The initiator secret must be unique for each host server that connects to the storage array and must not
be the same as the target CHAP secret.
1
From MD Storage Manager, click on the iSCSI tab, then select Enter Mutual Authentication
Permissions
.
2
3
Select an initiator on the host server and click the CHAP Secret
.
Enter the Initiator CHAP secret, confirm it in Confirm initiator CHAP secret, and click OK
.
NOTE: In some cases, an initiator CHAP secret may already be defined in your configuration. If so, use it
here.
4
Click Close
.
NOTE: To remove a CHAP secret, you must delete the host initiator and re-add it.
48
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
(optional)
If you configured CHAP authentication in Step 5: Configure CHAP Authentication on the Storage Array
(optional), complete the following steps. If not, skip to Step 7: Connect to the Target Storage Array from
the Host Server.
Select the set of steps in one of the following sections (Windows or Linux) that corresponds to your
operating system.
If you are using Windows Server 2003 or Windows Server 2008 GUI version
1
Click Start
→
Tools iSCSI Initiator
Programs
→
Microsoft iSCSI Initiator or Start
→
All Programs
→
Administrative
→
.
2
If you are NOT using mutual CHAP authentication:
skip to the step 4 below
If you are using mutual CHAP authentication:
•
3
•
•
•
click the General tab
select Secret
at Enter a secure secret, enter the mutual CHAP secret you entered for the storage array
4
5
Click the Discovery tab.
Under Target Portals, select the IP address of the iSCSI port on the storage array and click Remove
.
The iSCSI port you configured on the storage array during target discovery should disappear. You will
reset this IP address under CHAP authentication in the steps that immediately follow.
6
7
Under Target Portals, click Add and re-enter the IP address or DNS name of the iSCSI port on the
storage array (removed above).
Click Advanced and set the following values on the General tab:
•
•
•
Local Adapter: Should always be set to Microsoft iSCSI Initiator.
Source IP: The source IP address of the host you want to connect with.
Data Digest and Header Digest: Optionally, you can specify that a digest of data or header
information be compiled during transmission to assist in troubleshooting.
•
•
CHAP logon information: Enter the target CHAP authentication username and secret you
entered (for the host server) on the storage array.
Perform mutual authentication: If mutual CHAP authentication is configured, select this
option.
NOTE: IPSec is not supported.
Setting Up Your iSCSI Storage Array
49
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Click OK.
If discovery session failover is desired, repeat step 5 and step 6 (in this step) for all iSCSI ports on the
storage array. Otherwise, single-host port configuration is sufficient.
NOTE: If the connection fails, make sure that all IP addresses are entered correctly. Mistyped IP addresses
are a common cause of connection problems.
If you are using Windows Server 2008 Core Version
1
Set the iSCSI initiator services to start automatically (if not already set):
sc \\<server_name> config msiscsi start= auto
2
Start the iSCSI service (if necessary):
sc start msiscsi
3
4
If you are not using mutual CHAP authentication, skip to step 4.
Enter the mutual CHAP secret you entered for the storage array:
iscsicli CHAPSecret <secret>
5
6
Remove the target portal that you configured on the storage array during target discovery:
iscsicli RemoveTargetPortal <IP_address> <TCP_listening_port>
You will reset this IP address under CHAP authentication in the following steps.
Add the target portal with CHAP defined:
iscsicli QAddTargetPortal
<IP_address_of_iSCSI_port_on_storage_array> [CHAP_username]
[CHAP_password]
where
[CHAP_username]is the initiator name
[CHAP_password]is the target CHAP secret
If discovery session failover is desired, repeat step 5 for all iSCSI ports on the storage array. Otherwise,
If you are using Linux Server
1
Edit the /etc/iscsi.conf file to add an OutgoingUsername=and OutgoingPassword=entry
after each DiscoveryAddress=entry. OutgoingUsernameis the iSCSI initiator name entered
in Step 4: Configure Host Access, and the OutgoingPasswordis the CHAP secret created in Step
5: Configure CHAP Authentication on the Storage Array (optional).
For example, your edited /etc/iscsi.conf file might look like this:
DiscoveryAddress=172.168.10.6
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
50
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
OutgoingPassword=0123456789abcdef
DiscoveryAddress=172.168.10.7
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
DiscoveryAddress=172.168.10.8
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
DiscoveryAddress=172.168.10.9
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
If you are using Mutual CHAP authentication on Linux Server
If you are configuring Mutual CHAP authentication in Linux, you must also add an
IncomingUsername=and IncomingPassword=entry after each OutgoingPassword=entry.
The IncomingUsername is the iSCSI target name, which can be viewed in MD Storage Manager by
accessing the iSCSI tab and clicking Change Target Identification.
For example, your edited /etc/iscsi.conf file might look like this:
DiscoveryAddress=172.168.10.6
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
IncomingUsername=iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
IncomingPassword=abcdef0123456789
DiscoveryAddress=172.168.10.7
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
IncomingUsername=iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
IncomingPassword=abcdef0123456789
DiscoveryAddress=172.168.10.8
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
IncomingUsername=iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
IncomingPassword=abcdef0123456789
DiscoveryAddress=172.168.10.9
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
OutgoingPassword=0123456789abcdef
IncomingUsername=iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
IncomingPassword=abcdef0123456789
Setting Up Your iSCSI Storage Array
51
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are using RHEL 5 or SLES 10 SP1
1
To enable CHAP (optional), the following line needs to be enabled in your /etc/iscsi/iscsid.conf file.
node.session.auth.authmethod = CHAP
2
To set a username and password for CHAP authentication of the initiator by the target(s), edit the
following lines as shown:
node.session.auth.username = <iscsi_initiator_username>
node.session.auth.password = <CHAP_initiator_password>
3
If you are using Mutual CHAP authentication, you can set the username and password for CHAP
authentication of the target(s) by the initiator by editing the following lines:
node.session.auth.username_in= <iscsi_target_username>
node.session.auth.password_in = <CHAP_target_password>
4
5
To set up discovery session CHAP authentication, first uncomment the following line:
discovery.sendtargets.auth.authmethod = CHAP
Set a username and password for a discovery session CHAP authentication of the initiator by the
target(s) by editing the following lines:
discovery.sendtargets.auth.username = <iscsi_initiator_username>
discovery.sendtargets.auth.password = <CHAP_initiator_password>
6
7
To set the username and password for discovery session CHAP authentication of the target(s) by the
initiator for Mutual CHAP, edit the following lines:
discovery.sendtargets.auth.username = <iscsi_target_username>
discovery.sendtargets.auth.password_in = <CHAP_target_password>
As a result of steps 1 through 6, the final configuration contained in the /etc/iscsi/iscsid.conf file might
look like this:
node.session.auth.authmethod = CHAP
node.session.auth.username = iqn.2005-03.com.redhat01.78b1b8cad821
node.session.auth.password = password_1
node.session.auth.username_in= iqn.1984-
05.com.dell:powervault.123456
node.session.auth.password_in = test1234567890
discovery.sendtargets.auth.authmethod = CHAP
discovery.sendtargets.auth.username = iqn.2005-
03.com.redhat01.78b1b8cad821
52
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
discovery.sendtargets.auth.password = password_1
discovery.sendtargets.auth.username = iqn.1984-
05.com.dell:powervault.123456
discovery.sendtargets.auth.password_in = test1234567890
If you are using SLES10 SP1 via the GUI
1
2
3
4
5
6
7
Select Desktop
Click Service Start, then select When Booting
Select Discovered Targets, then select Discovery
Enter the IP address of the port.
Click Next
→
YaST
→
iSCSI Initiator.
.
.
.
Select any target that is not logged in and click Log in
.
Choose one:
•
If you are not using CHAP authentication, select No Authentication. Proceed to step 8.
or
•
If you are using CHAP authentication, enter the CHAP username and password. To enable
Mutual CHAP, select and enter the Mutual CHAP username and password.
8
9
Repeat step 7 for each target until at least one connection is logged in for each controller.
Go to Connected Targets
.
10 Verify that the targets are connected and show a status of true.
Setting Up Your iSCSI Storage Array
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 7: Connect to the Target Storage Array from the Host Server
If you are using Windows Server 2003 or Windows Server 2008 GUI
1
Click Start
→
Tools iSCSI Initiator
Programs
→
Microsoft iSCSI Initiator or Start
→
All Programs
→
Administrative
→
.
2
Click the Targets tab.
If previous target discovery was successful, the iqn of the storage array should be displayed under
Targets
.
3
4
5
6
Click Log On
Select Automatically restore this connection when the system boots
Select Enable multi-path
Click Advanced and configure the following settings under the General tab:
.
.
.
•
•
•
Local Adapter: Must be set to Microsoft iSCSI Initiator.
Source IP: The source IP address of the host server you want to connect from.
Target Portal: Select the iSCSI port on the storage array controller that you want to
connect to.
•
•
•
Data Digest and Header Digest: Optionally, you can specify that a digest of data or header
information be compiled during transmission to assist in troubleshooting.
CHAP logon information: If CHAP authentication is required, select this option and enter
the Target secret
.
option.
NOTE: IPSec is not supported.
7
Click OK
.
To support storage array controller failover, the host server must be connected to at least one iSCSI
port on each controller. Repeat step 3 through step 8 for each iSCSI port on the storage array that you
want to establish as failover targets (the Target Portal address will be different for each port you
connected to).
NOTE: To enable the higher throughput of multipathing I/O, the host server must connect to both iSCSI ports
on each controller, ideally from separate host-side NICs. Repeat step 3 through step 7 for each iSCSI port on
each controller. If using a duplex MD3000i configuration, then LUNs should also be balanced between the
controllers.
The Status field on the Targets tab should now display as Connected
Click OK to close the Microsoft iSCSI initiator.
.
8
NOTE: MD3000i supports only round robin load-balancing policies.
54
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are using Windows Server 2008 Core Version
1
2
3
Set the iSCSI initiator services to start automatically (if not already set):
sc \\<server_name> config msiscsi start= auto
Start the iSCSI service (if necessary):
sc start msiscsi
Log on to the target:
iscsicli PersistentLoginTarget <Target_Name> <Report_To_PNP>
<Target_Portal_Address> <TCP_Port_Number_Of_Target_Portal> * * *
<Login_Flags> * * * * * <Username> <Password> <Authtype> *
<Mapping_Count>
where
<Target_Name>is the target name as displayed in the target list. Use the iscsicli
ListTargetscommand to display the target list.
<Report_To_PNP>is T, which exposes the LUN to the operating system as a storage device.
<Target_Portal_Address>is the IP address of the iSCSI port on the controller being logged in
to.
<TCP_Port_Number_Of_Target_Portal>is 3260.
<Login_Flags>is 0x2to enable multipathing for the target on the initiator. This value allows more
than one session to be logged in to a target at one time.
<Username>is the initiator name.
<Password>is the target CHAP secret.
<Authtype>is either
0
for no authentication,
1
for Target CHAP, or
2
for Mutual CHAP.
NOTE: <Username>, <Password> and <Authtype> are optional parameters. They can be replaced with an
asterisk (*) if CHAP is not used.
<Mapping_Count>is 0, indicating that no mappings are specified and no further parameters are
required.
* * * An asterisk (*) represents the default value of a parameter.
For example, your logon command might look like this:
iscsicli PersistentLoginTarget
iqn.1984-05.com.dell:powervault.6001372000ffe333000000004672edf2
3260 T 192.168.130.101 * * * 0x2 * * * * * * * * * 0
Setting Up Your iSCSI Storage Array
55
Download from Www.Somanuals.com. All Manuals Search And Download.
To view active sessions to the target, use the following command:
iscsicli SessionList
To support storage array controller failover, the host server must be connected to at least one iSCSI
port on each controller. Repeat step 3 for each iSCSI port on the storage array that you want to
establish as a failover target. (The Target_Portal_Addresswill be different for each port you
connect to).
PersistentLoginTargetdoes not initiate a login to the target until after the system is rebooted.
To establish immediate login to the target, substitute LoginTargetfor
PersistentLoginTarget.
NOTE: Refer to the Microsoft iSCSI Software Initiator 2.x User’s Guide for more information about the
commands used in the previous steps. For more information about Windows Server 2008 Server Core, refer to
If you are using a Linux Server
If you configured CHAP authentication in the previous steps, you must restart iSCSI from the Linux
command line as shown below. If you did not configure CHAP authentication, you do not need to restart
iSCSI.
/etc/init.d/iscsi restart
Verify that the host server is able to connect to the storage array by running the iscsi -ls command as you
did in target discovery. If the connection is successful, an iSCSI session will be established to each iSCSI
port on the storage array.
Sample output from the command should look similar to this:
*******************************************************************************
SFNet iSCSI Driver Version ...4:0.1.11-3(02-May-2006)
*******************************************************************************
TARGET NAME
TARGET ALIAS
HOST ID
: iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
:
: 2
BUS ID
: 0
TARGET ID
: 0
TARGET ADDRESS
SESSION STATUS
SESSION ID
: 192.168.0.110:3260,1
: ESTABLISHED AT Wed May 9 18:20:27 CDT 2007
: ISID 00023d000001 TSIH 5
*******************************************************************************
TARGET NAME
TARGET ALIAS
HOST ID
: iqn.1984-05.com.dell:powervault.6001372000f5f0e600000000463b9292
:
: 3
BUS ID
: 0
TARGET ID
TARGET ADDRESS
: 0
: 192.168.0.111:3260,1
56
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
SESSION STATUS
SESSION ID
: ESTABLISHED AT Wed May 9 18:20:28 CDT 2007
: ISID 00023d000002 TSIH 4
*******************************************************************************
Viewing the status of your iSCSI connections
In MD Storage Manager, clicking the iSCSI tab and then Configure iSCSI Host Ports will show the
status of each iSCSI port you attempted to connect and the configuration state of all IP addresses. If
either displays Disconnected or Unconfigured, respectively, check the following and repeat the iSCSI
•
•
•
Are all cables securely attached to each port on the host server and storage array?
Is TCP/IP correctly configured on all target host ports?
Is CHAP set up correctly on both the host server and the storage array?
To review optimal network setup and configuration settings, see Guidelines for Configuring Your Network
for iSCSI.
Setting Up Your iSCSI Storage Array
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 8: (Optional) Set Up In-Band Management
Out-of-band management (see Step 1: Discover the Storage Array (Out-of-band management only)) is the
recommended method for managing the storage array. However, to optionally set up in-band
management, use the steps shown below.
The default iSCSI host port IPv4 addresses are shown below for reference:
Controller 0, Port 0: IP: 192.168.130.101
Controller 0, Port 1: IP: 192.168.131.101
Controller 1, Port 0: IP: 192.168.130.102
Controller 1, Port 1: IP: 192.168.131.102
NOTE: The management station you are using must be configured for network communication to the same IP
subnet as the MD3000i host ports.
NOTE: By default, the MD3000i host ports are not IPv6 enabled. To use IPv6 for in-band management, you
must first connect either out-of-band, or in-band using the default IPv4 addresses. Once this is done, you can
enable IPv6 and begin step 1 below using the IPv6 addresses.
1
2
3
Establish an iSCSI session to the MD3000i RAID storage array.
In either Windows or Linux, restart the SMagent service.
Launch MD Storage Manager.
If this is the first storage array to be set up for management, the Add New Storage Array window will
appear. Otherwise, click New
.
4
5
Select Manual and click OK
.
Select In-band management and enter the host server name(s) or IP address(es) of the host server that
is running the MD Storage Manager software.
6
Click Add.
In-band management should now be successfully configured.
58
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Premium Features
If you purchased premium features for your storage array, you can set them up at this point. Click
Tools→ View/Enable Premium Features or View and Enable Premium Features on the Initial Setup
Tasks dialog box to review the features available.
Advanced features supported by MD Storage Manager include:
•
•
Snapshot Virtual Disk
Virtual Disk Copy
To install and enable these premium features, you must first purchase a feature key file for each feature
and then specify the storage array that will host them. The Premium Feature Activation Card that shipped
in the same box as your storage array gives instructions for this process.
For more information on using these premium features, see the User’s Guide.
Troubleshooting Tools
The MD Storage Manager establishes communication with each managed array and determines the
current array status. When a problem occurs on a storage array, MD Storage Manager provides several
ways to troubleshoot the problem:
•
Recovery Guru — The Recovery Guru diagnoses critical events on the storage array and recommends
step-by-step recovery procedures for problem resolution. To access the Recovery Guru using MD
Storage Manager, click Support Recover from Failure. The Recovery Guru can also be accessed from
→
the Status area of the Summary page.
•
Storage Array Profile — The Storage Array Profile provides an overview of your storage array
configuration, including firmware versions and the current status of all devices on the storage array.
To access the Storage Array Profile, click Support
→
viewed by clicking the Storage array profile link in the Hardware Components area of the
View storage array profile. The profile can also be
Summary tab.
•
Status Icons — Status icons identify the six possible health status conditions of the storage array.
For every non-Optimal status icon, use the Recovery Guru to detect and troubleshoot the problem.
–
–
Optimal — Every component in the managed array is in the desired working condition.
Needs Attention — A problem exists with the managed array that requires intervention to
correct it.
–
–
Fixing — A Needs Attention condition has been corrected and the managed array is currently
changing to an Optimal status.
Unresponsive — The storage management station cannot communicate with the array, one
controller, or both controllers in the storage array. Wait at least five minutes for the storage array to
return to an Optimal status following a recovery procedure.
–
Contacting Device — MD Storage Manager is establishing contact with the array.
Setting Up Your iSCSI Storage Array
59
Download from Www.Somanuals.com. All Manuals Search And Download.
–
Needs Upgrade — The storage array is running a level of firmware that is no longer supported by
MD Storage Manager.
•
Support Information Bundle — The Gather Support Information link on the Support tab saves all
storage array data, such as profile and event log information, to a file that you can send if you seek
technical assistance for problem resolution. It is helpful to generate this file before you contact Dell
support with MD3000i-related issues.
60
Setting Up Your iSCSI Storage Array
Download from Www.Somanuals.com. All Manuals Search And Download.
Uninstalling Software
The following sections contain information on how to uninstall MD Storage Manager software from
both host and management station systems.
Uninstalling From Windows
Use the Change/Remove Program feature to uninstall MD Storage Manager from a
®
®
Microsoft Windows operating systems other than Windows Server 2008:
1
2
3
From the Control Panel, double-click Add or Remove Programs.
Select MD Storage Manager from the list of programs.
Click Change/Remove, and follow the prompts to complete the uninstallation process.
The Uninstall Complete window appears.
4
Select Yes to restart the system, and then click Done.
®
Use the following procedure to uninstall MD Storage Manager on Windows Server 2008 GUI
versions:
1
2
3
From the Control Panel, double-click Programs and Features
Select MD Storage Manager from the list of programs.
.
Click Uninstall/Change, then follow the prompts to complete the uninstallation process.
The Uninstall Complete window appears.
4
Select Yes to restart the system, then click Done.
Use the following procedure to uninstall MD Storage Manager on Windows Server 2008 Core
versions:
1
Navigate to the \Program Files\Dell\MD Storage Manager\Uninstall
Dell_MD_Storage_Manager directory.
NOTE: By default, MD Storage Manager is installed in the \Program Files\Dell\MD Storage Manager
directory. If another directory was used during installation, navigate to that directory before beginning
the uninstall procedure.
2
From the installation directory, type (command is case sensitive):
Uninstall Dell_MD_Storage_Manager
and press Enter
.
Uninstalling Software
61
Download from Www.Somanuals.com. All Manuals Search And Download.
3
4
From the Uninstall window, click Next and follow the on-screen instructions.
Select Yes to restart the system, then click Done
.
Uninstalling From Linux
Use the following procedure to uninstall MD Storage Manager from a Linux system.
1
By default, MD Storage Manager is installed in the /opt/dell/mdstoragemanager directory. If another
directory was used during installation, navigate to that directory before beginning the Uninstall
procedure.
2
From the installation directory, type
./uninstall_dell_mdstoragemanager
and press <Enter>.
3
4
From the Uninstall window, click Next, and follow the instructions that appear on the screen.
While the software is uninstalling, the Uninstall window is displayed. When the uninstall procedure is
complete, the Uninstall Complete window is displayed.
Click Done
.
62
Uninstalling Software
Download from Www.Somanuals.com. All Manuals Search And Download.
Guidelines for Configuring Your Network
for iSCSI
This section gives general guidelines for setting up your network environment and IP addresses for
use with the iSCSI ports on your host server and storage array. Your specific network environment
may require different or additional steps than shown here, so make sure you consult with your system
administrator before performing this setup.
Windows Host Setup
If you are using a Windows host network, the following section provides a framework for preparing
your network for iSCSI.
To set up a Windows host network, you must configure the IP address and netmask of each iSCSI
port connected to the storage array. The specific steps depend on whether you are using a Dynamic
Host Configuration Protocol (DHCP) server, static IP addressing, Domain Name System (DNS)
server, or Windows Internet Name Service (WINS) server.
NOTE: The server IP addresses must be configured for network communication to the same IP subnet
as the storage array management and iSCSI ports.
If using a DHCP server
1
On the Control Panel, select Network connections or Network and Sharing Center. Then click
Manage network connections
.
2
3
Right-click the network connection you want to configure and select Properties
On the General tab (for a local area connection) or the Networking tab (for all other connections),
select Internet Protocol (TCP/IP), and then click Properties
.
4
Select Obtain an IP address automatically, then OK
.
If using Static IP addressing
1
On the Control Panel, select Network connections or Network and Sharing Center. Then click
Manage network connections
.
2
3
Right-click the network connection you want to configure and select Properties.
On the General tab (for a local area connection) or the Networking tab (for all other connections),
select Internet Protocol (TCP/IP), and then click Properties
.
Network Configuration Guidelines
63
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Select Use the following IP address and enter the IP address, subnet mask, and default gateway
addresses.
If using a DNS server
1
On the Control Panel, select Network connections or Network and Sharing Center. Then click
Manage network connections
.
2
3
Right-click the network connection you want to configure and select Properties.
On the General tab (for a local area connection) or the Networking tab (for all other connections),
select Internet Protocol (TCP/IP), and then click Properties
.
4
Select Obtain DNS server address automatically or enter the preferred and alternate DNS server IP
addresses and click OK
.
If using a WINS server
NOTE: If you are using a DHCP server to allocate WINS server IP addresses, you do not need to add WINS
server addresses.
1
2
3
On the Control Panel, select Network connections
.
Right-click the network connection you want to configure and select Properties
.
On the General tab (for a local area connection) or the Networking tab (for all other connections),
select Internet Protocol (TCP/IP), and then click Properties
.
4
5
6
Select Advanced, then the WINS tab, and click Add
.
In the TCP/IP WINS server window, type the IP address of the WINS server and click Add
.
To enable use of the Lmhosts file to resolve remote NetBIOS names, select Enable LMHOSTS
lookup
.
7
8
To specify the location of the file that you want to import into the Lmhosts file, select Import
LMHOSTS and then select the file in the Open dialog box
Enable or disable NetBIOS over TCP/IP.
If using Windows 2008 Core Version
On a server running Windows 2008 Core version, use the netsh interface command to configure the
iSCSI ports on the host server.
Linux Host Setup
If you are using a Linux host network, the following section provides a framework for preparing your
network for iSCSI.
To set up a Linux host network, you must configure the IP address and netmask of each iSCSI port
connected to the storage array. The specific steps depend on whether you are configuring TCP/IP using
Dynamic Host Configuration Protocol (DHCP) or configuring TCP/IP using a static IP address.
64
Network Configuration Guidelines
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: The server IP addresses must be configured for network communication to the same IP subnet as the
storage array management and iSCSI ports.
Configuring TCP/IP on Linux using DHCP (root users only)
1
Edit the /etc/sysconfig/network file as follows:
NETWORKING=yes
HOSTNAME=mymachine.mycompany.com
2
Edit the configuration file for the connection you want to configure, either /etc/sysconfig/network-
scripts/ifcfg-ethX (for RHEL) or /etc/sysconfig/network/ifcfg-eth-id-XX:XX:XX:XX:XX (for SUSE).
BOOTPROTO=dhcp
Also, verify that an IP address and netmask are not defined.
3
Restart network services using the following command:
/etc/init.d/network restart
Configuring TCP/IP on Linux using a Static IP address (root users only)
1
Edit the /etc/sysconfig/network file as follows:
NETWORKING=yes
HOSTNAME=mymachine.mycompany.com
GATEWAY=255.255.255.0
2
Edit the configuration file for the connection you want to configure, either /etc/sysconfig/network-
scripts/ifcfg-ethX (for RHEL) or /etc/sysconfig/network/ifcfg-eth-id-XX:XX:XX:XX:XX (for SUSE).
BOOTPROTO=static
BROADCAST=192.168.1.255
IPADDR=192.168.1.100
NETMASK=255.255.255.0
NETWORK=192.168.1.0
ONBOOT=yes
TYPE=Ethernet
HWADDR=XX:XX:XX:XX:XX:XX
GATEWAY=192.168.1.1
3
Restart network services using the following command:
/etc/init.d/network restart
Network Configuration Guidelines
65
Download from Www.Somanuals.com. All Manuals Search And Download.
66
Network Configuration Guidelines
Download from Www.Somanuals.com. All Manuals Search And Download.
A
alerts, 38
iSNS, 35
C
cabling, 9-10
nonredundancy, 10
CHAP, 45
target, 45
Windows, 23-27
Linux host and server, 41
cluster host
setting up, 24
iSCSI, 31
DNS, 64
discovery, 36
Linux, 64
D
disk group, 8
manuals, 28, 30
target discovery, 40
password, 37
post-installation
configuration, 37
E
iSCSI configuration
worksheet, 33-34
enclosure connections, 9
event monitor, 24-26
expansion, 15
Premium Features, 59
premium features, 9
iSCSI initiator, 19
installing on Windows, 20
Index
67
Download from Www.Somanuals.com. All Manuals Search And Download.
R
RAID, 8
RDAC MPP driver, 26
readme, 28-29
virtual disk, 8-9
S
status, 37, 60
VSS, 25
status icons, 37, 59
storage array, 8
W
Storage Array Profile, 59
Windows, 19, 28, 61
planning, 9
T
troubleshooting, 59
68
Index