Crown Audio Stereo Amplifier FM1000A User Manual

®
FM1000A  
RF Amplifier Package  
User's Manual  
©2005 Crown Broadcast, a division of International Radio and Electronics, Inc.  
25166 Leer Drive, Elkhart, Indiana, 46514-5425 U.S.A.  
(574) 262-8900  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Section 1—Getting Acquainted  
1.1 Your Amplifier Package .......................................................................................1–2  
1.2 Amplifier Package Specifications.........................................................................1–3  
1.3 Safety Considerations..........................................................................................1–4  
1.3.1 Dangers ............................................................................................................1–4  
1.3.2 Warnings ..........................................................................................................1–4  
1.3.3 Cautions ...........................................................................................................1–4  
Section 2—Installation  
2.1 Operating Environment .....................................................................................2–2  
2.2 Tools Required ..................................................................................................2–2  
2.3 Unpacking.........................................................................................................2–2  
2.4 Preinstallation ...................................................................................................2–3  
2.4.1 Power Amplifier Modules .............................................................................2–3  
2.4.2 Hubble Twist Lock® Connector Wiring ........................................................2–4  
2.5 Installation ........................................................................................................2–5  
2.6 Remote I/O Connection.....................................................................................2–6  
Section 3—Operation  
3.1 Initial Power-up Procedures..............................................................................3–2  
3.2 Power Switches ................................................................................................3–4  
3.2.1 AC Input Circuit Breaker ...............................................................................3–4  
3.2.2 DC Power Switch..........................................................................................3–5  
3.2.3 Interlock Switch............................................................................................3–5  
3.3 Digital Multimeter .............................................................................................3–6  
3.4 Fault Indicators .................................................................................................3–7  
3.5 Fuse Indicators .................................................................................................3–8  
Section 4—Principles of Operation  
4.1 PA1000 Power Amplifier ...................................................................................4–2  
4.1.1 Power Modules ............................................................................................4–2  
4.1.2 Power Combiner Board ................................................................................4–2  
4.1.3 Backplane Assembly.....................................................................................4–3  
4.1.3.1  
4.1.3.2  
4.1.3.3  
Backplane DC Interconnect Board ........................................................4–3  
Input Divider Board...............................................................................4–3  
Output Combiner Board ........................................................................4–3  
4.1.4 Output Filter & Reflectometer .......................................................................4–3  
4.1.5 Metering and Control Board .........................................................................4–4  
4.1.6 DC Fuse and Power Distribution Board ........................................................4–4  
4.1.7 Cooling Fans.................................................................................................4–4  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2 PS1000 Power Supply ......................................................................................4–4  
4.2.1 AC Input Board .............................................................................................4–5  
4.2.2 PFC (Power Factor Correcting) Switching Board ..........................................4–5  
4.2.3 DC Output Board ..........................................................................................4–6  
4.2.4 Cooling Fans.................................................................................................4–6  
Section 5—Troubleshooting  
5.1 Troubleshooting Flow Chart Analysis ................................................................5–2  
5.2 Digital Multimeter Parameters ..........................................................................5–3  
5.2.1 In Ref (Input Drive Reference)......................................................................5–3  
5.2.2 SWR (Standing Wave Ratio) ........................................................................5–3  
5.2.3 ALC (Automatic Level Control) .....................................................................5–3  
5.2.4 Power Out ....................................................................................................5–3  
5.2.5 PA Temp .......................................................................................................5–4  
5.2.6 PA Voltage ....................................................................................................5–4  
5.2.7 Tot Current ...................................................................................................5–4  
5.2.8 PA1–8...........................................................................................................5–4  
5.3 Fault Indicators .................................................................................................5–5  
5.3.1 Antenna ........................................................................................................5–5  
5.3.2 RF Drive........................................................................................................5–5  
5.3.3 PA Temp .......................................................................................................5–5  
5.3.3.1  
Potential Causes for Non-functioning Cooling Fans ..............................5–5  
5.3.4 PA DC ...........................................................................................................5–6  
5.3.5 Multiple Indicators........................................................................................5–6  
Section 6—Reference Drawings  
6.1 Views ................................................................................................................6–2  
6.2 Diagrams and Schematics ................................................................................6–3  
Section 7—Service and Support  
7.1 Service..............................................................................................................7–2  
7.2 24–Hour Support ..............................................................................................7–2  
7.3 Spare Parts .......................................................................................................7–2  
Glossary  
Index  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I
INFORMATION  
Section 1—Getting Acquainted  
This section provides a general description of the FM1000A  
power amplifier system and introduces you to safety conventions  
used within this document. Review this material before install-  
ing or operating the amplifier and power supply.  
Getting Acquainted  
1–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I
1.1 Your Amplifier Package  
The FM1000A is a highly efficient amplifier package designed to set a new standard  
in FM transmitter design offering modularity, ease of use, and long-term reliabil-  
ity. The FM1000A package includes a PA1000 amplifier, PS1000 power supply, and  
an FM1K accessory pack.  
The PA1000 broadband amplifier requires no tuning and typically provides 80% RF  
efficiency across the band. The PS1000 power supply is power factor corrected and  
90% efficient. Modern MOSFET technology ensures high AC to RF efficiency  
(better than 70% overall) and long-term reliability. The unmatched efficiency of  
this power amplifier significantly improves your bottom line by providing cooler  
operation and lower power costs.  
These modular units are uniquely designed to be lightweight and compact for  
convenient shipping, and require only seven RU spaces for installation. Installa-  
tion is made simple with just three interconnections between the amplifier and  
power supply. In addition, built-in digital metering and status indicator capabili-  
ties enable intuitive operation to further augment the user-friendly design.  
Economic long-term reliability is ensured through our carefully engineered solid-  
state design. The PA1000 features two field-replaceable 500–watt power modules.  
This power amplifier delivers 500 to over 1000 watts of RF power output. Use your  
existing exciter or purchase the FM1000T which includes our award-winning FM30  
exciter for an unbeatable 1 kW transmitter package.  
Metering  
Fault  
Fuses  
PA1  
PA2  
PA3  
PA4  
PA5  
PA6  
PA7  
PA8  
Antenna  
RF Drive  
PA Temp  
PA DC  
PA3  
PA  
4
PA8  
Power Out  
PA Temp  
PA7  
In Ref  
SWR  
ALC  
PA Voltage  
Tot Current  
®
Power  
I
O
®
Illustration 1–1 FM1000A Amplifier Package  
1–2  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2 Amplifier Package Specifications  
RF Power Output:  
100 to 1100 watts continuous with remote  
controlled power adjust  
RF Drive Requirement:  
30 watts for full output  
RF Output Impedance:  
Maximum SWR:  
50 ohms (unbalanced)  
1.7:1 (With power foldback at high SWR)  
87–108 MHz  
Frequency Range:  
RF Harmonics/Spurious Products: Better than –80 dB  
Asynchronous AM S/N Ratio:  
Synchronous AM S/N Ratio:  
Better than –55 dB with 100% modulation at  
400 Hz, no de-emphasis, no FM modulation  
(typically > 60 dB)  
Better than –55 dB with 100% modulation at  
400 Hz, no de-emphasis, FM  
modulation=75 kHz @400 Hz  
(typically > 60 dB)  
Operating Environment:  
Temperature Range:  
Humidity Range:  
0°–50°C at sea level  
0–80% at 20°C (noncondensing)  
240 Volts AC +10/-15%, 50–60 Hz  
AC Power:  
Power Consumption:  
Less than 1400 watts at 1000 watts RF output  
typical  
Power Factor:  
.96 typical  
Overall Efficiency:  
RF Output Connector:  
Power Amplifier Chassis:  
70% typical  
7/8 in. EIA flange, 7–16 in DIN optional  
7 x 17.25 x 23 inches (17.78 x 43.82 x  
58.42 cm) exclusive of rack ears, but inclu-  
sive of connectors  
Power Supply Chassis:  
Weight:  
5.25 x 17.25 x 23 inches (13.34 x 43.82 x  
58.42 cm) exclusive of rack ears  
PA1000—40 pounds (18.1 kg)  
RF PA Modules—8 pounds (3.6 kg) each  
PS1000—43 pounds (19.5 kg)  
Note: System performance is specified using Crown Broadcast  
Model FM30 Exciter where applicable.  
Getting Acquainted  
1–3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I
1.3 Safety Considerations  
Crown Broadcast assumes the responsibility for providing you a safe product and  
safety guidelines during its use. “Safety” means protection to all individuals who  
install, operate, and service the transmitter as well as protection of the transmitter  
itself. To promote safety, we use standard hazard alert labeling on the product and  
in this manual. Follow the associated guidelines to avoid potential hazard.  
1.3.1 Dangers  
DANGER represents the most severe hazard alert. Extreme bodily harm or death  
will occur if DANGER guidelines are not followed.  
1.3.2 Warnings  
WARNING represents hazards which could result in severe injury or death.  
1.3.3 Cautions  
CAUTION indicates potential personal injury or equipment or property damage if  
the associated guidelines are not followed. Particular cautions in this text also  
indicate unauthorized radio-frequency operation.  
Type of Hazard  
WARNING  
Severe shock hazard!  
Turn power off and  
Pictorial Indication  
of Hazard  
Explanation of  
Hazard  
wait approximately 1  
minute for capacitors  
to discharge before  
handling them.  
Illustration 1–3 Sample Hazard Alert  
1–4  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Section 2—Installation  
This section provides important guidelines for installing your  
power amplifier and power supply. Review this information care-  
fully for proper installation.  
Installation  
2–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.1 Operating Environment  
You can install the FM1000A amplifier system in a standard 19–inch component  
rack or on a suitable surface such as a bench or desk. In any case, the area should  
be as clean and well-ventillated as possible. The power supply must be installed  
directly above or below the power amplifier (for the included dressed cables to  
reach their respective connectors).  
2.2 Tools Required  
To install the power supply and power amplifier, you will need the following tools:  
Medium phillips screwdriver  
Medium flat-blade screwdriver  
Small flat-blade screwdriver  
7/16–Inch wrench or nut driver  
ESD (Electrostatic Discharge) protection grounding strap and/or mat.  
2.3 Unpacking  
Before handling any exposed printed circuit boards, ground yourself with an  
antistatic strap and/or mat.  
CAUTION  
Possible equipment damage!  
Guard against electrostatic discharge  
through electronic components.  
The power amplifier, power supply, and two power amplifier modules are packed  
and shipped in individual boxes because of their modular nature. (The FM1K  
accessory kit is packed inside one of the two power amplifier module boxes.) For  
added protection, both the PA1000 amplifier and PS1000 supply are packed in an  
inner box and then placed inside an outer box with styrofoam protective corners in  
both boxes. You will need to unpack a total of four boxes (plus two inner boxes).  
Note: Save the boxes and packaging material that the individual  
units are packed in should you need to return them for factory  
service.  
2–2  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 Preinstallation  
2.4.1 Power Amplifier Modules  
The PA1000 incorporates four power amplifiers (two each in two modules). Due to  
possible damage during shipment, the power modules have been removed. Follow  
these steps to install the modules:  
1. Remove the front panel of the PA1000 (four screws).  
2. Taking ESD precautions (see page 2–2), unpack the power modules and place  
them on your work area with the circuit sides up.  
Connector  
Warning Label  
Slide Rail  
Illustration 2–1 Power Amplifier Module  
3. The warning labels on the front of the modules should all be positioned to the  
center of the chassis, also note the position of the connector on the modules  
and in the chassis.  
4. Insert the two power modules, using their slide rails, into the built in chan-  
nels of the right-side cavity as shown below. Note that the connectors and  
warning labels are nearest the middle wall or partition of the PA1000.  
Module A  
(amps 3 & 4)  
Module B  
(amps 7 & 8)  
Middle Partition  
Vacant Cavity  
Illustration 2–2 Power Amplifier Module Placement  
5. Be sure the modules are pushed in completely so that the connector makes  
proper contact.  
6. Replace the front panel of the PA1000.  
Installation  
2–3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4.2 Hubble Twist Lock® Connector Wiring  
Prepare the wiring for the Hubble Twist-Lock® connector in the following manner  
before connecting to your AC power source:  
1. Use round cord with a diameter of 0.385–0.780 inches (10–20 mm), Type SJ  
12/3 – 10/3; Type S 16/3 – 10/3.  
2. Select conductor size from your National Electrical Code®.  
3. Slide the cover onto the cord. Remove insulation from cable and conductors  
as shown in Illustration 2–3. Do not tin conductors.  
1 Inch  
(25 mm)  
5/8 Inch  
(16 mm)  
Illustration 2–3 Cover, Cable & Conductors  
4. Loosen terminal screws. Insert conductors fully into proper terminals ac-  
cording to the table below. Take caution that there are no stray wire strands.  
Terminal  
Conductor  
Equipment grounding conductor  
(green or green/yellow)  
Green Hex Head Screw  
Hot circuit conductor, 240 VAC  
Brass Screw  
(NOT white, NOT green)  
Brass/Black Screw  
Hot circuit conductor, 240 VAC  
(NOT white, NOT green)  
5. Tighten terminal screws to 18 pound• inches (2.1 Nm) of torque.  
6. Tighten assembly screws to 10 pound• inches (1.1 N• m) of torque.  
7. Tighten cord clamp screws to 10 pound• inches (1.1 N• m) of torque.  
WARNING  
Possible Electric Shock Hazard!  
Do not connect AC source until all  
other connections are made and  
installation is complete.  
2–4  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5 Installation  
1. Mount the units in an appropriate 19–inch wide cabinet. The power supply  
must be installed directly below the power amplifier for the included  
cables to reach their respective connectors (see illustration 2–4 below).  
Note: The PS1000 weighs approximately 40 pounds (18.1 kg); the  
PA1000, approximately 43 pounds (19.5 kg). Use help to install.  
2. Ensure that the PS1000 power switch is off, the circuit breakers of the 240  
VAC source on the back panel are off, and the AC connector is not plugged in.  
3. Install the exciter source (such as a Crown Broadcast FM30) according to its  
instructions.  
4. Connect the RF input cable from the exciter source to the N connector on the  
back of the PA1000.  
5. Connect the RF output cable (from the antenna) to the 7/8 EIA or 7-16 DIN  
connector on the back of the PA1000.  
6. Connect one end of the supplied control cable to the 9–pin D-sub connector  
on the PA1000.  
7. Connect the other end of the control cable to the 9–pin D-sub connector on  
the PS1000.  
+ DC Input  
DC Input  
RF Monitor  
(Optional Connection)  
RF Input  
Ground Screws  
Air Intakes/Filters  
Remote I/O  
RF Output  
Control  
PA1000  
Circuit Breakers  
+ DC Output  
OFF  
OFF  
Fans  
Power  
Control  
DC Output  
Air Exhaust Vents  
PS1000  
240 VAC IN  
Illustration 2–4 Rear Panel Connections  
Installation  
2–5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Using the supplied connector, tie together pins 6 and 7 of the Remote I/O  
connector. The amplifier will not operate without this connection or a  
remote switch on these pins. (See Section 2.6 for Remote I/O connection.)  
9. If monitoring of the output signal is desired, connect the RF monitor cable to  
the BNC connector on the PA1000.  
10. Connect the DC input/output cables between the PA1000 and the PS1000 as  
illustrated (Illustration 2–4). The connector end with the ground lead con-  
nects to the PA1000. Be sure to attach the ground leads as indicated.  
Note: The power lead shield is only grounded at the PA chassis.  
11. Install the covers over the DC terminals of the PA1000 and the PS1000 using  
hardware form the hardware kit (1/4–inch X 6–32 bolts with lock washers).  
12. Connect to your AC power source by inserting the Hubble Twist-Lock connec-  
tor into the female Hubble connector on the PS1000 and turn to the right  
until the connection locks.  
2.6 Remote I/O Connection  
The Remote I/O Connector on the back of the PA1000 allows remote control and  
monitoring of Certain transmitter functions. There are three basic control func-  
tions—AC on/off, RF power level adjustment, and RF down/off.  
The AC power on/off remote control function, available at pin 7 of the Remote I/O  
Connector, turns DC power to the PA on when the pin is grounded.  
The RF power level adjustment remote control function has an internal maximum  
limit set on the Metering and Control Board. The Local Power Adjust (R62) sets  
the maximum limit of RF power output. The limit is set by placing the Remote/  
Local switch (SW5) in the LOCAL position and adjusting the Local Power Adjust to  
your desired maximum limit (see illustrations 2–5 and 2–6). However, for any  
remote operation to work, the Remote/Local slide switch must be in the REMOTE  
position. Then the on-board remote RAISE and LOWER push buttons and any  
external remote switches attached to pins 4 and 15 of the I/O Connector can adjust  
+5V  
MAXIMUM  
R62  
LOCAL  
POWER  
ADJUST  
MINIMUM  
REMOTE  
RAISE POWER  
LOCAL  
Electro-  
Control  
Circuit  
TANSMITTER  
CONTROL  
Pin 4  
Remote I/O Conn.  
SW5  
SW3  
RAISE  
REMOTE  
REMOTE  
LOWER POWER  
Pin 15  
Remote I/O Conn.  
SW4  
LOWER  
Illustration 2–5 Local and Remote Functions  
2–6  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the level up to that limit and down to zero. When a specific output power level is  
set, the Metering and Control Board controls and maintains the setting to keep the  
power constant. The location of the Local Power Adjust (R62), the on-board Raise  
and Lower switches (SW3 & SW4), and the Local/Remote slide switch (SW5) are  
shown below.  
Local/Remote  
Slide Switch  
On-board Remote  
Power Adjust  
Buttons  
Local Power Adjust  
Pot  
Illustration 2–6 On-board Remote Power & Related Controls  
Another remote control function, available at pin 5 of the Remote I/O Connector,  
turns RF down/off. Connecting this pin to ground through a resistor allows the  
RF power output level of the amplifier to be reduced below the internal limit set by  
the Local Power Adjust pot or the remote Raise/Lower settings. However, some  
drive power, less than one watt, may still be present at the antenna. Depending on  
the resistor used, this pin can serve as a control for optional low power operation.  
The remaining remote functions are for monitoring the various  
parameters of the PA1000. They are either buffered metering outputs, direct  
reading, or latched high/low indications. Further details of these functions are  
described in the pin-out table on page 2–8.  
Note: If Remote I/O controls are not used, tie pin 7 to pin 6 (GND.).  
For remote I/O (Input/Output) connection, connect your remote I/O cable from  
your remote control location to the 25–pin (female) D-sub connector on the back  
panel of the PA1000. The I/O Connector on the power amplifier is described in the  
following diagram:  
13  
1
25  
14  
Illustration 2–7 Remote I/O connector (back panel view)  
The Remote I/O Connector Pinout Table on the next page summarizes the Remote  
I/O pin connections.  
Installation  
2–7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pin #  
Function  
PA#8 Current Monitor (a buffered metering output with 1 V = 2 A)  
PA#7 Current Monitor (a buffered metering output with 1 V = 2 A)  
Ground  
1
2
3
4
Remote RAISE Power (a momentary switch, on this pin, when held low will  
raise the power level 10 watts every 0.5 seconds)  
5
Remote RF Power Control (a resistor to ground on this pin reduces RF  
power output level below internal limits. See Section 2.6, page 2–7)  
6
7
Ground  
Remote AC Power On (a latching switch, on this pin, when held low will turn  
the AC power supply on)  
8
Fault Summary (the voltage from this pin goes to +5 V if any fault occurs and  
drops below 2V when the fault goes away)  
9
Ground  
10  
ALC (the voltage from this pin is a direct reading of automatic level control  
voltage, not buffered)  
11  
12  
PA Temperature (a buffered metering output with 1 V = 20° C)  
SWR (a buffered metering output with a calculated reading of standing wave  
ratio in VDC)  
13  
14  
15  
RF Output Power (a buffered metering output with a calculated reading of  
output power of 1 V = 1000 W)  
Input Power Reference (a buffered metering output with a DC voltage  
representing input power)  
Remote LOWER Power (a momentary switch, on this pin, when held low will  
lower the power level 10 watts every 0.5 seconds)  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
PA#6 Current Monitor (a buffered metering output with 1 V = 2 A)  
PA#5 Current Monitor (a buffered metering output with 1 V = 2 A)  
Ground  
PA#4 Current Monitor (a buffered metering output with 1 V = 2 A)  
PA#3 Current Monitor (a buffered metering output with 1 V = 2 A)  
Ground  
PA#2 Current Monitor (a buffered metering output with 1 V = 2 A)  
PA#1 Current Monitor (a buffered metering output with 1 V = 2 A)  
PA Total Current Monitor (a buffered metering output with 1 V = 20 A)  
PA Volts (a buffered metering output with 1 V = 10 V)  
Note: PA = Power Amplifier  
Remote I/O Connector Pinout Table  
2–8  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 3—Operation  
This section provides general operating parameters of your power  
amplifier system and a detailed description of the front panel  
display.  
Operation  
3–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1 Initial Power-up Procedures  
These steps summarize the operating procedures you should use for the initial  
operation of the power amplifier and power supply. More detailed information  
follows.  
1. Ensure that the external remote control unit is properly connected (See the  
Pin Out Description Table, Section 2.6, page 2–8 for proper pin configura-  
tion). If not using a remote control unit, pin 7 must be tied to ground pin 6.  
2. Connect Antenna.  
3. If using an external remote control, enable the power supply via the remote  
I/O connector.  
4. Turn on (flip up) the AC input circuit breaker located on the rear panel of the  
power supply (do not turn on the front panel power switch yet).  
Outputs to  
PA1000  
Fan  
Circuit Breaker  
AC Input  
Circuit Breaker  
+ DC Output  
OFF  
OFF  
Fans  
Power  
Control  
DC Output  
PS1000  
Air Exhaust Vents  
240 VAC IN  
Illustration 3–1 PS1000 Back Panel Functions  
5. Turn on the exciter (a Crown FM30 or equivalent) and adjust its RF power  
output level until the In Reference (In Ref) voltage, as indicated on the  
PA1000 front panel Digital Multimeter, is between 0.4 and 0.8volts. This is  
not a drive dependent amplifier; therefore drive must be at a constant level  
regardless of main output power.  
Note: The unit will not operate until the exciter is active.  
3–2  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Before power-up, place the Local/Remote switch (located on the Metering &  
Control board behind the front panel) in the Local position and adjust the  
output power limit to the mid-level position using the Local Power Adjust,  
also on the Metering & Control board (see Illustration 3–2 below). The unit is  
normally shipped with this setting. See Section 2.6 for setting up remote  
operation and using the on-board remote buttons and other controls.  
7. Turn on the main power switch located on the front panel of the power  
supply. (The unit typically takes 30 seconds to power up.)  
Local/Remote  
Slide Switch  
On-board Remote  
Power Adjust  
Buttons  
Local Power Adjust  
Pot  
Illustration 3–2 Local Power Adjust and Other Controls  
8. Check the PA1000 parameters with the Digital Multimeter for a current (Tot  
Current) of 20 to 30 amps and a voltage (PA Voltage) of 25 to 35 volts. If  
parameters are within range, increase the Local Power Adjust to the maxi-  
Air Intakes/Filters  
Power  
I
O
®
Power Switch  
Illustration 3–3 PS1000 Front Panel Functions  
mum level of desired operation.  
Note: The Local Power Adjust pot is unconventional (CW lowers power).  
9.Using an external remote control unit connected to the Remote I/O connector,  
adjust the PA1000 to the maximum power set by the Local Power Adjust.  
(This prevents adjusting to higher than permitted power levels.)  
Operation  
3–3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Verify that the following conditions are present as indicated by the PA1000s  
Digital Multimeter:  
a. In Ref—Should read between 0.4 and 0.8 volts (0.5 nominal, dependent  
upon power input level).  
b. SWR—Should read 1.05 to 1.5.  
c. ALC—Should read between 4.00 and 6.00 volts for 1.1 kW output (less  
for lower output or danger conditions, i.e. high SWR).  
d. Power Out—Should read 1.10 for 1.1 kW output.  
e. PA Temp—Should read 35 to 50°C with ambient temperature of 25°C.  
The remainder of this section describes the functions of the front and rear panel  
indicators and switches of the PA1000 and PS1000.  
3.2 Power Switches  
3.2.1 AC Input Circuit Breaker  
The PS1000 supplies power to the PA1000 by converting single-phase 220/240 VAC  
into 50 VDC. The PS1000 is protected by a 20 A, double-pole circuit breaker  
located on the rear panel. This AC input circuit breaker must be in the “up”  
position (as shown below) for operation.  
AC Input  
Circuit Breaker  
ON  
ON  
Fans  
Power  
Control  
240 VAC IN  
Illustration 3–4 AC Input Circuit Breaker  
3–4  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.2 DC Power Switch  
The main on/off power switch located on the front panel of the power supply  
controls high voltage output. (The control circuit activates this voltage.)  
Power  
I
O
®
Power Switch  
Illustration 3–5 DC Power Switch  
3.2.3 Interlock Switch  
This switch is located on the fan mounting bracket in the power supply. When the  
top cover of the power supply is removed, the Interlock Switch interrupts the  
power supply control circuit disabling the high and low voltage supplies.  
Lethal voltages are still present on the AC Input Board !  
WARNING  
So, handle with care.  
Interlock Switch  
Illustration 3–6 Interlock Switch  
Operation  
3–5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3 Digital Multimeter  
The 3–digit numeric display in the upper left corner of the front panel provides  
information on the amplifiers operation. Use the up” and “down” push-buttons to  
select one of the following parameters as indicated by a green LED.  
Multimeter  
Metering Selection Buttons  
Metering Indicators  
Metering  
Fault  
PA1  
PA5  
PA6  
PA7  
PA8  
Antenna  
RF Drive  
PA Temp  
PA DC  
PA3  
Power Out  
PA Temp  
PA2  
PA3  
PA4  
In Ref  
SWR  
ALC  
PA Voltage  
Tot Current  
®
Illustration 3–7 Digital Multimeter  
In Ref—Input reference is a relative voltage level used to determine input RF  
power level. This varies between frequency of operation and input power level.  
SWR—Direct reading of the antenna Standing-Wave Ratio (the ratio of the actual  
load impedance to the desired 50 ohm load impedance).  
ALCAutomatic level control is DC gain control bias used to regulate PA supply  
voltage. With the PA power supply at full output voltage, ALC will read about 6.0  
volts. When the RF output is being regulated by the RF power control circuit, this  
voltage will be reduced, typically reading 5.0 to 6.0 volts. The ALC voltage will be  
reduced during PA DC overcurrent, SWR, or overtemperature conditions.  
Power OutActually reads RF voltage squared, so the accuracy can be affected by  
SWR. Tolerance of ± 10% is normal. For exact set-up on site, an external power  
meter is recommended.  
PA Temp—Highest temperature of all individual RF power amplifier heatsinks in  
degrees C.  
PA Voltage—Supply voltage of the RF power amplifier.  
Tot Current—Sum total current of all individual RF power amplifiers in amperes.  
PA1–8—Individual RF amplifier current reading in amperes.  
3–6  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 Fault Indicators  
Faults are indicated by illuminated red LEDs when the following occurs:  
Antenna—Load SWR exceeds 1.5:1. ALC voltage is reduced to limit the reflected  
RF power.  
RF Drive—Lack of or insufficient RF drive. If the RF drive fault LED is lit, input  
drive must be increased. To achieve full output power, 30 watts of input drive is  
required.  
CAUTION  
Possible equipment damage!  
Do not exceed 40 watts of input drive.  
Damage to the PA1000 will result if  
this level is exceeded.  
PA Temp—PA heatsink temperature is greater than 75°C (power foldback will  
begin at this point).  
PA DC—Power supply current for the PA (power amplifier) is at the preset limit, or  
there is a difference of more than 2.5 amps in current between the individual PAs.  
When this indicator is on ALC, the voltage is reduced automatically which holds  
the supply current to the preset limit.  
Fault Indicators  
Metering  
Fault  
Fuses  
PA1  
PA2  
PA3  
PA4  
PA5  
PA6  
PA7  
PA8  
Antenna  
RF Drive  
PA Temp  
PA DC  
PA3  
PA4  
Power Out  
PA Temp  
PA7  
PA8  
In Ref  
SWR  
ALC  
PA Voltage  
Tot Current  
®
Illustration 3–8 Fault Indicators  
Operation  
3–7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.5 Fuse Indicators  
The PA1000 consists of two field-replacable power modules with two amplifiers in  
each module. Each of the paralleled amplifiers is protected by a 10 ampere  
fast-acting fuse. When a fuse opens, the indicator light next to it illuminates.  
Fuses 3 and 4 represent amplifiers 1 and 2 on the top right module. Fuses 7 and 8  
represent amplifiers 3 and 4 on the lower right power module.  
Fuses and Indicators  
Fault  
Fuses  
PA1  
PA2  
PA3  
PA4  
PA5  
PA6  
PA7  
PA8  
Antenna  
RF Drive  
PA Temp  
PA DC  
PA3  
PA4  
Out  
mp  
PA7  
PA8  
tage  
rrent  
®
Illustration 3–9 Fuse Indicators  
3–8  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ue  
n ha  
'e n  
ta ci  
i
a
o
n
t
p
o
o
s
a
r
e
v
l
a
i
r
r
e
ue  
o
o
f
a
n
r
u
l
o
i
a
.
o
n
t
o
s
n ha  
e
a
m
e
l
e
a
i
d
i
o
n
f
a
r
l
u
o
ta ci  
.
p
a
r
v
l
a
i
r
r
e
ue  
n ha  
'e n  
i
a
'e n  
ta ci  
'e n  
o
n
o
t
s
e
a
m
e
l
l
e
a
i
d
o
i
o
f
a
n
r
u
l
o
.
p
a
r
v
l
a
i
e
r
r
a
e
m
e
l
e
a
i
d
i
ta ci  
e
a
m
e
e
p
a
i
a
d
r
i
v
l
a
i
r
r
e
ta ci  
p
a
r
v
l
a
i
r
r
e
ta ci  
p
o
a
e
r
v
i
l
a
r
r
e
ue  
n ha  
'e n  
i
a
o
n
t
o
s
o
f
a
n
u
r
l
o
.
e
a
m
l
e
a
i
d
i
ta ci  
la  
a
e
r
l
v
i
a
r
Section 4—Principles of Operation  
This section discusses the circuit principles upon which the  
power amplifier and power supply function. This information is  
not needed for day-to-day operation, but may be useful for ad-  
vanced users and service personnel.  
Principles of Operation  
4–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to mo  
s
n
e
d
i
v
e
n
d
o
r
u
o
c
c
o
n
q
,
s
u
e
n
o
si  
a
n
u
d
i
,
i
c
o m  
t
o
e
m
s
n
e
e
d
s
o
r
o c  
h
q
,
m
o
i
a
f
c
e
c
o
s
i
u
n
i
n
d
d
i
,
i
c
e
s
r
e
a
v
e
nd  
o
s
ri  
s
c
o
f
s
u
e
o
n
to mo  
m
n
d
e
o
o c  
q
,
i
a
m
h
h
c
c
e
c
e
c
i
s
n
o
si  
n
u
d
d
i
,
i
c
e
e
s
e
nd  
o c  
n
o
r
s
ri  
v
m
o c  
o
i
a
h
o
o
f
c
e
c
n
n
i
d
a
e
a
m
e
m
i
a
e
nd  
o
c
v
ri  
i
c
s
s
c
d
s
o
n
a
e
v
ri  
d
o
s
m
m
v
e
nd  
o
ri  
c
c
o
d
s
n
a
to mo  
s
n
m
e
u
o
,
q
n
o
si  
o c  
h
nd  
n
u
d
i
,
i
c
e
e
s
r
m
o
i
a
f
c
e
c
i
d
e
v
ri  
e
o
s
c
s
o
n
a
m
Introduction  
The FM1000A is a solid state RF amplifier package designed to deliver 500 to 1000  
watts. The package consists of two separate, compact units—a power supply  
(PS1000) and a power amplifier (PA1000). In turn, these units consist of modular  
components which provide for efficient operation as well as ease-of-service.  
4.1 PA1000 Power Amplifier  
The PA1000 power amplifier features adjustable output to deliver 500–1000 watts of  
RF output power for broadcast transmission. The amplifier is broadband; no tuning  
is required. The design, however, ensures efficient operation. Typical RF efficiency  
is 75% to 85% across the FM band.  
4.1.1 Power Modules  
The primary components of the PA1000 are two, 500–watt power modules. These  
power modules are mounted by stacking two in the right cavity of the chassis. The  
two slots on the left side are unpopulated.  
The chassis of the power modules acts as a heat sink for the MOSFET amplifiers.  
There are two power amplifiers mounted to spacer plates on each of the heat sinks,  
for a total of four power amplifiers in all. (The power amplifiers are the same as  
those utilized in the Crown Broadcast 100, 250, and 500–watt transmitters.)  
Power from the amplifiers is combined through a micro-strip combiner to convert  
from 50 output impedance for each amplifier to an intermediate impedance and  
then return to the 50 output at the Low Pass Filter. This technology eliminates  
tuning and adjustments throughout the 88–108 FM band and enables each amplifier  
to equally share the power load. The power combiner is also designed to allow a  
module to be disconnected from the combiner and removed without adversely  
affecting the impedance balance of the unit. With one module removed the imped-  
ance change allows the remaining module to continue operation at approximately  
one-third of the full output power.  
4.1.2 Power Combiner Board  
There are two Power Combiner Boards; one attached to each of the two heatsinks  
overlapping the amplifiers. Each board takes the power from two amplifiers and  
combines it through a parallel quarter-wave transmission line transformer network.  
The power is then summed in a common point junction on the Output Combiner  
Board.  
4–2  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.1.3 Backplane Assembly  
The backplane assembly is located in the vertical center of the PA1000 behind the  
power modules. The Backplane Assembly is the common connection point for the  
major sections of the transmitter. This assembly consists of the Input Divider  
Board, Output Combiner Board, and Backplane Interconnect Board.  
4.1.3.1 Backplane DC Interconnect Board  
This board is located nearest the metal inner brace of the chassis. It distributes DC  
power to each of the four MOSFET amplifiers, provides the interconnections for  
control of the power supply, and enables connection to the remote control inter-  
face. The Backplane/DC Interconnect Board contains interconnections from the  
Control and Metering Board to the DC Fuse and Power Distribution Board, as well  
as power connections to the power amplifier modules.  
4.1.3.2 Input Divider Board  
The Input Divider Board is the middle board sandwiched between the Backplane DC  
Interconnect Board and the Output Combiner Board. It provides the power division  
and impedance transformation needed to supply proper drive to each of the four  
amplifiers (two modules).  
4.1.3.3 Output Combiner Board  
The Output Combiner Board is located nearest the Output Filter It consists of a  
micro-strip transmission line that combines the output power from the four ampli-  
fiers (two modules) so that ultimately, all the power comes together at one common  
point junction. Here the currents and voltages of all four power amplifiers are in  
phase and producing equal RF output power. From this common point junction,  
the Output Combiner Board uses a second quarter-wave transformer to convert the  
output power to the 50–ohm impedance needed at the output of the unit.  
4.1.4 Output Filter & Reflectometer  
The Output Filter/Reflectometer is located behind the Backplane Assembly in the  
center of the PA1000. See the accompanying schematic in Section 6 for more  
information.  
The ninth-order, elliptic, low-pass filter attenuates harmonics generated in the  
power amplifier. The capacitors for the filter are circuit board pads. The reflecto-  
meter uses printed circuit board traces for micro-strip transmission lines. Trans-  
mission line segments (with an impedance of about 100 ohms) on either side of a  
50–ohm conductor provide sample voltages representative of the square root of  
forward and reverse power. DC voltages, representative of forward and reflected  
power, go through a bulkhead Filter Board to the Backplane/DC Interconnect  
Board, then to the Metering Board where they are processed for power control and  
metering and for SWR metering and protection.  
Principles of Operation  
4–3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to mo  
s
n
e
d
i
v
e
n
d
o
r
u
o
c
c
o
n
q
,
s
u
e
n
o
si  
a
n
u
d
i
,
i
c
o m  
t
o
e
m
s
n
e
e
d
s
o
r
o c  
h
q
,
m
o
i
a
f
c
e
c
o
s
i
u
n
i
n
d
d
i
,
i
c
e
s
r
e
a
v
e
nd  
o
s
ri  
s
c
o
f
s
u
e
o
n
to mo  
m
n
d
e
o
o c  
q
,
i
a
m
h
h
c
c
e
c
e
c
i
s
n
o
si  
n
u
d
d
i
,
i
c
e
e
s
e
nd  
o c  
n
o
r
s
ri  
v
m
o c  
o
i
a
h
o
o
f
c
e
c
n
n
i
d
a
e
a
m
e
m
i
a
e
nd  
o
c
v
ri  
i
c
s
s
c
d
s
o
n
a
e
v
ri  
d
o
s
m
m
v
e
nd  
o
ri  
c
c
o
d
s
n
a
to mo  
s
n
m
e
u
o
,
q
n
o
si  
o c  
h
nd  
n
u
d
i
,
i
c
e
e
s
r
m
o
i
a
f
c
e
c
i
d
e
v
ri  
e
o
s
c
s
o
n
a
m
4.1.5 Metering and Control Board  
The Metering and Control Board is located above the upper left cavity. This board  
supplies readings of voltages and currents, and provides information on the opera-  
tion of the amplifier.  
The Local Power Adjust pot sets the upper limit (maximum) of RF power output.  
The on-board RAISE and LOWER push buttons and any external remote control of  
the power level is activated within that limit by placing the Local/Remote slide  
switch on the board into the Remote position. When a specific output power is set,  
the Metering and Control Board controls and maintains the setting keeping power  
constant. A long-life battery supplies power to retain the power setting after the  
amplifier is turned off.  
This board also takes samples from the RF amplifier boards and PS1000 power  
supply and processes all the data. It provides SWR readings from the Output Filter  
and folds back the amplifier power if the SWR exceeds safe operating limits. Protec-  
tion circuitry for overcurrent and overtemperature conditions is designed into this  
board as well, providing additional precaution against overheating. This board is  
fail-safe, like all the other circuit board components in the FM1000A and can be  
removed for repair/replacement if necessary.  
4.1.6 DC Fuse and Power Distribution Board  
This board is located above the right cavity over Power Modules A and B. The DC  
Fuse and Power Distribution Board takes power direct from the power supply  
through one 80–amp power line, divides it into four separate DC power lines, and  
distributes it to the four power amplifiers. Metering resistors in each of the four  
power lines monitor the current drawn by each of the four amplifiers to ensure  
proper function for monitor and control of the unit.  
4.1.7 Cooling Fans  
There is a cooling fan located in the back of the PA1000 powered by the PS1000.  
The fan operates at 24 volts and is rated at 235 cubic feet per minute. Cool air is  
drawn through the heatsinks where a flushing moves the air over the DC Distribu-  
tion Fuse board, the Control and Metering Board, the Output Filter circuits, and  
then out through the air vents on the side panel. If a fan fails, the amplifier will  
fold back power to prevent overheating.  
4.2 PS1000 Power Supply  
The PS1000 supplies power to the PA1000 by converting single-phase 240  
VAC into 50 VDC. The PS1000 is protected by a 20 A double-pole circuit breaker.  
This highly efficient power supply utilizes switching technology and is power factor  
corrected. The PS1000 consists of three printed circuit boards described below.  
4–4  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2.1 AC Input Board  
The AC Input Board is located on the left side of the PS1000. AC power from the  
circuit breaker connects to the AC Input Board where it connects to a ±12 volt DC  
power supply and three relays. The ±12 volts is used to close the three relays when  
the DC Power Switch on the front panel is switched on. In addition, the ±12 volts  
are supplied to the PA1000 for use in the Control and Metering Board. The 240-  
volt AC input to the power supply is connected through a Hubble Twist Lock  
connector on the back panel to a 20–amp circuit breaker mounted inside the back  
panel.  
When the power supply is turned on and enabled, the AC power comes through  
torroidal inductors which prevent harmonics and spurious products from feeding  
back into the AC power lines. The current flows from the inductors to a bridge  
rectifier that converts the current to DC Power, and from there to the PFC Switch-  
ing Board where the rectified DC is filtered. The filtered DC power is then fed from  
the PFC Switching Board through an 80–turn boost inductor and back to the PFC  
Switching Board.  
4.2.2 PFC (Power Factor Correcting) Switching Board  
The PFC Switching Board is located directly behind the cooling fans (front panel) in  
the PS1000. This board takes the voltage from the Torroidal Boost Inductor and  
sends it to the Boost Switching Transistor. The switching transistor chops the DC  
input power at a 25 kHz rate. The chopped voltage is then rectified, filtered, and  
sent as DC voltage to a set of four transistors which form a second switching stage.  
The second switching stage chops the DC voltage at a 22.5 kHz rate. This chopped  
DC power is fed through a blocking capacitor to a transformer on the DC Output  
Board. The second switching stage controls the amount of power sent to the DC  
Output Board. This ensures that the transformer output voltage and current are  
correct for providing the selected RF output power to the amplifier.  
Principles of Operation  
4–5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to mo  
s
n
e
d
i
v
e
n
d
o
r
u
o
c
c
o
n
q
,
s
u
e
n
o
si  
a
n
u
d
i
,
i
c
o m  
t
o
e
m
s
n
e
e
d
s
o
r
o c  
h
q
,
m
o
i
a
f
c
e
c
o
s
i
u
n
i
n
d
d
i
,
i
c
e
s
r
e
a
v
e
nd  
o
s
ri  
s
c
o
f
s
u
e
o
n
to mo  
m
n
d
e
o
o c  
q
,
i
a
m
h
h
c
c
e
c
e
c
i
s
n
o
si  
n
u
d
d
i
,
i
c
e
e
s
e
nd  
o c  
n
o
r
s
ri  
v
m
o c  
o
i
a
h
o
o
f
c
e
c
n
n
i
d
a
e
a
m
e
m
i
a
e
nd  
o
c
v
ri  
i
c
s
s
c
d
s
o
n
a
e
v
ri  
d
o
s
m
m
v
e
nd  
o
ri  
c
c
o
d
s
n
a
to mo  
s
n
m
e
u
o
,
q
n
o
si  
o c  
h
nd  
n
u
d
i
,
i
c
e
e
s
r
m
o
i
a
f
c
e
c
i
d
e
v
ri  
e
o
s
c
s
o
n
a
m
4.2.3 DC Output Board  
The DC Output Board is located in the back of the unit directly behind the PFC  
Switching Board. This board rectifies and filters the transformer output voltage  
once again to produce the clean DC power required for the power modules. The DC  
Output Board also provides the 24–volts that operate the cooling fans in both the  
PS1000 and the PA1000. There are two parallel paths from the DC Output Board,  
with half the power going through each set of output cables. These cables come  
together at the terminal in back of the unit providing the maximum output power  
of 50 volts at 60 amperes.  
4.2.4 Cooling Fans  
There are two cooling fans located in the front section of the PS1000. Their pri-  
mary function is to cool the semiconductors used in the switching and rectifying  
process which are subject to high currents. The fans blow cool air through the  
heatsinks and out through the vents on the back and side panels of the PS1000.  
The fans have a dedicated circuit breaker located on the back panel of the power  
supply.  
4–6  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE  
Section 5—Troubleshooting  
This section describes procedures for service personnel to diag-  
nose and troubleshoot potential fault conditions in the power  
amplifier and power supply.  
Troubleshooting  
5–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE  
5.1 Troubleshooting Flow Chart Analysis  
Does your  
amplifier have  
output power?  
See Section 3.1  
Initial Power-up  
procedures.  
Is power  
output at the  
proper level?  
Yes  
No  
Do you have  
power now?  
Yes  
No  
Is exciter delivering  
sufficient RF drive?  
(Check In Ref meter  
reading.)  
Is your exciter  
turned on?  
Yes  
No  
See Section 3.1  
Initial Power-up  
procedures.  
Are there any  
fault  
indicators?  
Yes  
No  
Yes  
No  
Yes  
No  
Turn the  
exciter on.  
Antenna: See  
Section 5.3.1  
Secure all  
connections to the  
PS2000.  
RF Drive: See  
Section 5.3.2  
Ensure AC input  
circuit breaker is  
flipped up  
PA Temp: See  
Section 5.3.3  
Ensure main  
power switch is  
turned on.  
PA DC:  
See  
Section 5.3.4  
Call Support—  
See Section 8  
5–2  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.2 Digital Multimeter Parameters  
The following procedures are general in nature; for in-depth service, and repair see  
the Service & Support section of this manual.  
WARNING  
Lethal voltages present!  
Only technically qualified  
individuals shoud attempt  
troubleshooting or service  
procedures.  
If any abnormal readings are displayed for any of the following parameters on the  
Digital Multimeter, try troubleshooting in the following manner:  
5.2.1 In Ref (Input Drive Reference)  
If this indication of drive level is not between 0.4 and 0.8 volts, then:  
q Check the exciter to ensure proper power input level of 25–30 watts.  
q Check RF input cable for secure connection.  
5.2.2 SWR (Standing Wave Ratio)  
If the SWR is over 1.5:1, then look for:  
q effects of inclement weather such as icing on the antenna and feed line.  
q for moisture in the feedline.  
q insecure antenna connections.  
5.2.3 ALC (Automatic Level Control)  
If this indication is not between 4.00 and 6.00 volts for 1.1 kW output, then:  
q Check for overheating (see PA Temp fault LED).  
q Check for overcurrent (see PA DC fault LED).  
q Check for high SWR (see Antenna fault LED).  
5.2.4 Power Out  
This reading is user adjustable, but for full output should read 1.10 for 1.1 kW.  
q If lower than desired, check for proper input drive, and/or proper adjustment  
of the Local Power Control (see section 3.1 #6).  
Troubleshooting  
5–3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE  
5.2.5 PA Temp  
The meter should read between 35–50°C with an ambient temperature of 25°C. If  
temperature is 75°C or above, then check and do the following:  
Ambient temperature higher than 50°C; reduce temperature.  
Restricted air flow; remove any obstructions, clean dirty air filters by using  
mild detergent and warm water.  
Possible antenna mismatch; check for icing, moisture in the feedline, and  
secure antenna connections.  
Overcurrent: If PA DC fault indicator is flashing, monitor the current for a  
proper level—the total current and the current of individual Power Amps.  
5.2.6 PA Voltage  
Supply voltage to the RF power amplifiers should be 50 V. If it is not check:  
drive level to ensure proper power level input of 30 watts  
for high SWR  
for overcurrent; check PA DC fault indicator and if flashing, check current for  
proper levels (total and individual Power Amps)  
for overtemperature; ambient temperature higher than 50°C; reduce tempera-  
ture. Check air flow; remove any obstructions and clean dirty air filters.  
5.2.7 Tot Current  
If total current reading is over 35 amperes, then check or do the following:  
Reduce power output; check all fault indicators and troubleshoot accordingly.  
If one or more of the 250–watt power modules has failed; replace.  
High SWR; check for icing, moisture in the feedline, and secure antenna  
connections.  
5.2.8 PA1–8  
If there is 2.5 amps or more difference between the individual PA current readings  
(7 to 9 amps typical), then check the following:  
Failed/faulty power module (reading directly correlates to failed power mod-  
ule); replace.  
Blown individual power amplifier fuses 1–8; replace as indicated by red LED.  
Reduced power output; check all fault indicators and troubleshoot accordingly.  
5–4  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.3 Fault Indicators  
If one of the LED fault indicators is illuminated red, troubleshoot using the follow-  
ing suggestions:  
5.3.1 Antenna  
Antenna mismatch.  
Effects from inclement weather conditions such as icing.  
Check for moisture in the feedline.  
Secure antenna connections.  
5.3.2 RF Drive  
Denotes lack of or insufficient drive level.  
Ensure proper drive level of 25–30 watts input power.  
Check RF input cable for secure connection.  
5.3.3 PA Temp  
Temperature has reached the internal preset limit for safe operation (75°C).  
Ambient temperature higher than 50°C; reduce temperature.  
Restricted air flow; remove any obstructions, clean dirty air filters by using  
mild detergent and warm water.  
Antenna mismatch; check for icing, moisture on the feedline, and secure  
antenna connections.  
Overcurrent; check PA DC fault indicator, if flashing monitor current for  
proper levels (total and individual Power Amps).  
Faulty DC Output Board; replace (see Section 7, Service & Support).  
Faulty or non-functioning cooling fan; determine the cause for malfunction  
in the following section.  
5.3.3.1 Potential Causes for Non-functioning Cooling Fans  
The PA1000 has one and the PS1000 has two cooling fans each. All three fans are  
powered by the same circuit of the PS1000. There are two potential causes for a  
non-functioning fan or fans:  
1. If a single fan does not operate, the fan is faulty and must be replaced. (See  
Section 7, Service & Support.)  
2. If none of the fans operate, a blown circuit breaker, a short circuit in the  
PS1000, or a damaged winding on the main transformer of the DC Output  
Board (in the PS1000) is the cause. In this case, do one of the following:  
Troubleshooting  
5–5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE  
a. The circuit breaker is located on the rear panel of the power supply. If the  
breaker has popped out, reset it by pushing it in. If the breaker continues  
to trip, check for a short circuit.  
b. Check each fan with a volt-ohm meter by disconnecting and testing it for a  
short circuit. Replace the fan/fans as needed (see Section 7).  
c. If none of the fans have short circuits, there is damage on the  
winding of the transformer. It will have to be replaced (see Section 7).  
5.3.4 PA DC  
Discrepancy in current between the individual amplifiers, or in total current.  
There is a difference of current greater than 2.5 amps between any one of the  
4 individual amplifiers. This could occur as a result of a blown or faulty power  
module, or a blown fuse; replace as appropriate (see Section 7, Service &  
Support).  
There is too much total current—power foldback will occur above maximum  
total amperage of 35 amps due to antenna mismatch. Examine the antenna  
for arcing and moisture. Also, check output power for proper current; the RF  
detection circuit could malfunction causing an overcurrent situation.  
5.3.5 Multiple Indicators  
Call your Crown Broadcast service representative. See Section 7, Service and  
Support, for contact information.  
Fuses  
Fault  
Metering  
P
A
7
A
8
P
A
2
4
P
A
5
P
A
6
P
A
3
P
A
A
ntenna  
F Drive  
mp  
P
A
1
P
r
O
ut  
P
A
1
P
A
5
P
owe  
PA  
2
3
PA  
6
7
R
In  
R
e
f
PA  
T
emp  
PA  
PA  
T
e
PA  
V
oltage  
PA  
S
W
R
P
A
P
A
8
PA  
DC  
ALC  
Tot  
Current  
4
®
Power  
I
O
®
5–6  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 6—Reference Drawings  
The illustrations in this section may be useful for making  
adjustments, taking measurements, troubleshooting, or  
understanding the circuitry of your RF power amplifier and  
power supply.  
Reference Drawings  
6–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.1 Views  
Metering  
Fault  
Fuses  
PA1  
PA2  
PA3  
PA4  
PA5  
PA6  
PA7  
PA8  
Antenna  
RF Drive  
PA Temp  
PA DC  
PA3  
PA  
4
PA8  
Power Out  
PA Temp  
PA7  
In Ref  
SWR  
ALC  
PA Voltage  
Tot Current  
®
Power  
I
O
®
Illustration 6–1 Front View  
+ DC Input  
DC Input  
RF Monitor  
(Optional Connection)  
RF Input  
Ground Screws  
Air Intakes/Filters  
Remote I/O  
RF Output  
Control  
PA1000  
Circuit Breakers  
+ DC Output  
OFF  
OFF  
Fans  
Power  
Control  
DC Output  
Air Exhaust Vents  
PS1000  
240 VAC IN  
Illustration 6–2 Back View  
6–2  
FM1000A User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.2 Diagrams and Schematics  
1 kW RF  
Power Output  
RF Input  
Excitation  
PA1000  
Power Amplifier  
30 W Exciter  
(Crown FM30)  
Remote I/O  
Connector  
Power Supply  
Control  
0–50 VDC  
PA Supply  
PS1000  
Power Supply  
240 VAC  
50/60 Hz Input Power  
Single Phase  
Illustration 6–3 FM1000A Block Diagram  
Reference Drawings  
6–3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AC INPUT  
AC  
CIRCUIT  
BREAKER  
360 VDC  
240 VAC  
220 VDC  
AC  
INPUT  
CCA  
RECTIFIER  
+ 0 to 50 VDC  
RETURN  
NEUTRAL  
GROUND  
PFC &  
CONTROL  
CCA  
DC  
OUTPUT  
CCA  
360 VDC  
CONTROL  
+/ 12 VDC  
POWER  
SWITCH  
VOLTAGE  
BOOST  
INDUCTOR  
9-PIN  
DSUB  
PS CONTROL  
Illustration 6–4 PS1000 Block Diagram  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Illustration 6–5 PA1000 Block Diagram  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: All bypass capacitors are 0.01 mf  
Backplane Distribution  
6–13  
Reference Drawings  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ribbon Cables and Connectors  
Ribbon Cables and Connectors  
FM1000A User's Manual  
6–14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes:  
6–16  
FM1000A User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 7—Service and Support  
We understand that you may need various levels of support or  
that the product could require servicing at some point in time.  
This section provides information for both of these scenarios.  
Service and Support  
7–1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7.1 Service  
The product warranty (see opposite page) outlines our responsibility for defective  
products. Before returning a product for repair or replacement (our choice), call  
our Customer Service department using the following telephone number:  
(866) 262-8917  
Our Customer Service Representative will give you further instructions regarding  
the return of your product. Use the original shipping carton or a new one obtained  
from Crown. Place shipping spacers between the slide-out power amplifier assem-  
bly and the back panel.  
Please fill out the Factory Service Instructions sheet (page 7–5) and include it with  
your returned product.  
7.2 24–Hour Support  
In most instances, what you need to know about your product can be found in this  
manual. There are times when you may need more in-depth information or even  
emergency-type information. We provide 24–hour technical assistance on your  
product via a toll telephone call.  
For emergency help or detailed technical assistance, call  
(866) 262-8917  
You may be required to leave a message at this number but your call will be  
returned promptly from our on-call technician.  
7.3 Spare Parts  
To obtain spare parts, call Crown Broadcast Sales at the following number.  
(866) 262-891  
You may also write to the following address:  
Service Manger  
International Radio and Electronics Company, Inc.  
25166 Leer Drive  
Elkhart, Indiana, U.S.A. 46514-5425  
FM1000A User's Manual  
7–2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Crown Broadcast Three Year Limited Product Warranty  
SUMMARY OF WARRANTY  
Crown Broadcast, IREC warrants its broadcast products to the ORIGINAL PURCHASER of a NEW Crown  
Broadcast product, for a period of three (3) years after shipment from Crown Broadcast. All products are  
warranted to be free of defects in materials and workmanship and meet or exeed all specifications published  
by Crown Broadcast. Product nameplate with serial number must be intact and not altered in any way. This  
warranty is non - transferable. This warranty in its entirety is the only warranty offered by Crown Broadcast. No  
other warranties, expressed or implied, will be enforceable.  
EXCLUSIONS  
Crown Broadcast will not warranty the product due to misuse, accident, neglect and improper installation or  
operation. Proper installation included A/C line surge supression, lightning protection and proper grounding of  
the entire transmitter, and any other recommendations designated in the Instruction manual. This warranty  
does not extend to any other products other than those designed and manufactured by Crown Broadcast. This  
warranty does not cover any damage to any accessory such as loads, transmission line or antennas resulting  
from the use or failure of a Crown Broadcast transmitter. Warranty does not cover any loss of revenue resulting  
from any failure of a Crown Broadcast product, act of God, or natural disaster.  
Procedure for Obtaining Warranty Service  
Crown Broadcast will repair or service, at our discretion, any product failure as a result of normal intended use.  
Warranty repair can only be performed at our plant facility in Elkhart, Indiana USA or at a factory authorized  
service depot. Expenses in remedying the defect will be borne by Crown Broadcast, including two-way ground  
transportation cost within the continental United States.  
Prior to returning any product or component to Crown Broadcast for warranty work or repair, a Return  
Authorization (RA) number must be obtained from the Crown Broadcast Customer Service Department.  
Product must be returned in the original factory pack or equivalent. Original factory pack materials may be  
obtained at a nominal charge by contacting Crown Broadcast Customer Service. Resolution of the defective  
product will be made within a reasonable time from the date of receipt of the defective product.  
Warranty Alterations  
No person has the authority to enlarge, amend, or modify this warranty, in whole or in part. This warranty is not  
extended by the length of time for which the owner was deprived the use of the product. Repairs and  
replacement parts that are provided under the terms of this warranty shall carry only the unexpired portion of  
the warranty.  
Product Design Changes  
Crown Broadcast reserves the right to change the design and manufacture of any product at any time without  
notice and without obligation to make corresponding changes in products previously manufactured.  
Legal Remedies of Purchaser  
This written warranty is given in lieu of any oral or implied warranties not covered herein. Crown Croadcast  
disclaims all implied warranties including any warranties of merchantability or fitness for a particular purpose.  
Crown Broadcast  
25166 Leer Drive  
Elkhart, Indiana 46514-5425  
Phone 574-262-8900 Fax 574-262-5399 www.crownbroadcast.com  
Service and support  
7 – 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes:  
FM1000A User's Manual  
7–4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Factory Service Instructions  
To obtain factory service, complete the bottom half of this page, include it with the unit, and ship to:  
International Radio and Electronics Company, Inc.  
25166 Leer Drive  
Elkhart, Indiana, U.S.A. 46514-5425  
For units in warranty (within 3 years of purchase from any authorized Crown Dealer): We pay for  
ground UPS shipments from anywhere in the continental U.S. and Federal Express Second Day service  
from Hawaii and Alaska to the factory and back to you. Expedited service/shipment is available for an  
additional charge. You may ship freight collect (COD for cost of freight) or forward your receipt for  
shipping charges which we will reimburse. We do not cover any charges for shipping outside the U.S.  
or any of the expenses involved in clearing customs.  
If you have any questions about your Crown Broadcast product, please contact Crown Broadcast  
Customer Service at:  
Telecphon: (574) 262-8900  
Fax: (574) 262-5399  
Name:  
Company:  
Shipping Address:  
Phone Number:  
Model:  
Fax:  
Serial Number:  
Purchase Date:  
Nature of the Problem  
(Describe the conditions that existed when the problem occurred and what attempts were made to correct it.)  
Other equipment in your system:  
If warranty has expired, payment will be: Cash/Check  
Please Quote before servicing  
VISA  
Mastercard  
Other  
COD  
Card Number:  
Exp. Date:  
Signature:  
Return Shipment Preference if other than UPS Ground:  
Expedite Shipment  
ENCLOSE WITH UNITDO NOT MAIL SEPARATELY  
Service and Support  
7–5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A B C  
Glossary  
The following pages define terms and abbreviations used  
throughout this and other Crown Broadcast manuals.  
Glossary  
G1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A B C  
AF  
Audio Frequency; the frequencies between 20 Hz  
and 20 kHz in the electromagnetic spectrum.  
ALC  
AM  
Automatic Level Control  
Amplitude Modulation; the process of impressing  
information on a radio-frequency signal by varying  
its amplitude.  
bandwidth  
BCD  
The range of frequencies available for signalling.  
Binary-Coded Decimal; a digital system that uses  
binary codes to represent decimal digits.  
BFO  
BNC  
Beat Frequency Oscillator  
A bayonet locking connector for miniature coax;  
said to be short for Bayonet-Neill-Concelman.  
broadband  
As used in the FM transmitter, refers to the entire  
audio spectrum as opposed to the spectrum influ-  
enced by the pre-emphasis; also called "Wideband."  
carrier  
A continuous signal which is modulated with a  
second, information-carrying signal.  
crosstalk  
In FM broadcasting, this term generally refers to  
the interaction between the main (L+R) and the  
subcarrier (L–R) signals as opposed to "separation"  
which generally refers to leakage between left (L)  
and right (R) channels.  
density (program)  
deviation  
A high average of modulation over time.  
The amount by which the carrier frequency  
changes either side of the center frequency.  
DIP  
Dual In-line Package; term used to describe an IC  
or socket that has two parallel rows of pins.  
distortion  
The unwanted changes in signal wave shape that  
occur during transmission between two points.  
DPM  
Digital Panel Meter  
EPROM  
ESD  
Erasable Programmable Read Only Memory  
Electrostatic Discharge; a discharge that is poten-  
tially distructive to sensitive electronic compo-  
nents.  
FM1000A User's Manual  
G2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
exciter  
(1) A circuit that supplies the initial oscillator used  
in the driver stage. (2) A transmitter configuration  
which excludes stereo generation and audio  
processing.  
FET  
Field-Effect Transistor  
frequency synthesizer  
A circuit that generates precise frequency signals  
by means of a single crystal oscillator in conjunc-  
tion with frequency dividers and multipliers.  
FM  
Frequency Modulation; the process of impressing  
information on a radio signal by varying its fre-  
quency.  
FSK  
Frequency Shift Keying; an FM technique for  
shifting the frequency of the main carrier at a  
Morse code rate. Used in the on-air identification  
of frequencies.  
gain reduction  
harmonics  
HF  
The process of reducing the gain of a given ampli-  
fier.  
Undesirable energy at integral multiples of a  
desired, fundamental frequency.  
High Frequency; Frequencies in the 3.0 to 30.0  
MHz range.  
Highband  
IC  
Frequencies affected by the pre-emphasis.  
Integrated Circuit  
I/O  
Input/Output  
LED  
Light-Emitting Diode  
modulation  
The process by which a carrier is varied to repre-  
sent an information-carrying signal.  
MOSFET  
nearcast  
PA  
Metal Oxide Semiconductor Field Effect Transistor;  
a voltage-controlled device with high input imped-  
ance due to its electrically isolated gate.  
A transmission within a localized geographic area  
(ranging from a single room to a several kilome-  
ters).  
Power Amplifier  
Glossary  
G3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A B C  
PAI  
Power Amplifier Current  
PAV  
Power Amplifier Voltage  
pilot  
A 19–kHz signal used for stereo transmissions.  
pre-emphasis  
The deliberate accentuation of the higher audio  
frequencies; made possible by a high-pass filter.  
processing  
The procedure and/or circuits used to modify  
incoming audio (keeping its level around 75 kHz  
deviation) to make it suitable for transmission.  
receiver  
RF  
An option which adds incoming RF capability to an  
existing transmitter. See also "Translator."  
Radio Frequency; (1) A specific portion of the  
electromagnetic spectrum between audio-fre-  
quency and the infrared portion. (2) A frequency  
useful for radio transmission (roughly 10 kHz and  
100,000 MHz).  
SCA  
Subsidiary Communications Authorization; see  
"subcarrier."  
S/N  
Signal to Noise  
spurious products  
Unintended signals present on the transmission  
output terminal.  
stability  
A tolerance or measure of how well a component,  
circuit, or system maintains constant operating  
conditions over a period of time.  
stereo pilot  
See "pilot."  
stereo separation  
The amount of left-channel information that bleeds  
into the right channel (or vice versa).  
subcarrier  
A carrier signal which operates at a lower fre-  
quency than the main carrier frequency and which  
modulates the main carrier.  
suppression  
The process used to hold back or stop certain  
frequencies.  
FM1000A User's Manual  
G4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWR  
Standing-Wave Ratio; on a transmission line, the  
ratio of the maximum voltage to the minimum  
voltage or maximum current to the minimum  
current; also the ratio of load impedance to in-  
tended (50 ohms) load impedance.  
THD  
Total Harmonic Distortion  
translator  
A transmitter designed to internally change an FM  
signal from one frequency to another for retrans-  
mission. Used in conjunction with terrestrial-fed  
networks.  
satellator  
UHF  
A transmitter equipped with an FSK ID option for  
rebroadcasting a satellite-fed signal.  
Ultra High Frequency; frequencies in the 300 to  
3000 MHz range.  
VCO  
VHF  
Voltage-Controlled Oscillator  
Very High Frequency; frequencies in the 30 to 300  
MHz range.  
VSWR  
Voltage Standing-Wave Ratio; see "SWR."  
See "broadband."  
Wideband  
Glossary  
G5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
H
A
Humidity Range 1–3  
AC Input Board 4–5  
AC Power 1–3  
AC power 2–4  
ALC 3–4, 5–3  
Antenna 3–7  
I
In Ref 3–4, 5–3  
Input Divider Board 4–3  
Installation 2–5  
mismatch 5–5  
antenna 2–5  
Interlock Switch 3–5  
B
L
Backplane Assembly 4–3  
labels 1–4  
Backplane DC Interconnect Board 4–3  
Board Layouts 6–3  
M
Metering and Control Board 4–4  
multimeter display 3–4  
C
Circuit Breaker 3–4  
Combiner Board 4–2  
Connections 2–5  
O
operation 3–2  
Output Combiner Board 4–3  
Output Filter & Reflectometer 4–3  
Connectors  
Hubble Twist Lock® 2–4  
Hubble Twist-Lock 2–6  
connectors 2–5  
P
PA DC 5–6  
PA Temp 3–4, 5–4  
PA Voltage 5–4  
D
DC Fuse and Power Distribution Board  
4–4  
PFC (Power Factor Correcting)  
Switching Board 4–5  
power adjust 3–3  
Power Consumption 1–3  
Power Factor 1–3  
Power Module 4–2  
Power Out 3–4, 5–3  
Power Switch 3–4  
power switch 3–3  
Power-up 3–2  
DC Output Board 4–6  
DC Power Switch 3–5  
Digital Multimeter 3–6, 5–3  
E
Efficiency 1–3  
efficiency 1–2  
exciter 1–2  
F
Fans 4–4, 4–6, 5–5  
Fault Indicators 3–7, 5–5  
Frequency Range 1–3  
Fuse Indicators 3–8  
Index-i  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
T
remote I/O 2–7  
Tot Current 5–4  
RF Drive Requirement 1–3  
RF Harmonics 1–3  
RF Output Impedance 1–3  
RF output power 1–2  
RF Power Output 1–3  
RF power output 1–2  
RU spaces 1–2  
transmitter package 1–2  
Troubleshooting Flow Chart 5–2  
U
Unpacking 2–2  
W
Weight 1–3  
S
S/N Ratio 1–3  
Safety 1–4  
Schematics 6–3  
Spurious Products 1–3  
SWR 1–3, 3–4, 5–3  
Index-ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion Car Video System DXZ555MP User Manual
Conair Styling Iron CS44CS User Manual
Country Home Products Log Splitter 6 TON User Manual
Crane Humidifier EE 5949 User Manual
Cuisinart Toaster CPT 180 User Manual
Cygnett Portable Speaker iPod Speaker User Manual
Dodge Automobile 2004 Caravan User Manual
Fellowes Paper Shredder PS 67Cs User Manual
Generac Power Systems Portable Generator 004987 2 005396 0 User Manual
Generac Switch 4678 1 User Manual