[ Page 1 ]  
BLAST CHILLER INTRODUCTION  
THE BLAST CHILLER is the easiest and simplest way to chill foods safely without additional labor. All food  
service operators prepare foods in advance or chill foods at the end of a workday. More often than not the foods  
are chilled in standard refrigeration, often creating an unsafe time and temperature environment. In using a  
BLAST CHILLER food products are produced in the same manner and with the same equipment which is  
used for conventional food preparation and chilled in a BLAST CHILLER. The BLAST CHILLER  
resembles a reach in refrigerator. The BLAST CHILLER is a unit that moves cool air at a high circulation  
over the top and bottom of each pan thus ensuring a rapid even chilling time. Almost all foods are chilled  
within 2 hours out of the danger zone 140°F to 41°F. The time necessary to bring the internal food temperature  
to 41°F. (5°C) is affected by the food density, moisture content and the food’s ability to retain heat. Blast  
chilled food has a shelf life of five days, including day of production and service. Blast chilling works well  
with a wide range of menu items. Nearly any food product that can be portioned into a standard 2-1/2” hotel  
pan can be successfully blast chilled. These systems are used for services from 50 to 10,000 meals per day.  
STEPS IN THE BLAST CHILL PROCESS  
1.  
2.  
3.  
4.  
5.  
Prepare all food products to the point of consumption. Within 30 minutes, portion into 2-1/2 inch deep  
half-full pan or sheet pan at a depth of no more than 2 inches and weight of no more than 8 lbs.  
Place pans of cooked product in the BLAST CHILLER and strategically place probe in the center of  
the pan where the internal temperature is brought down to approximately 41°F (5°C) within 90 minutes.  
At the completion of the “chill cycle” the pans of food product are removed and covered with either a  
film wrap or stainless steel lid and labeled.  
The product is stored in a refrigerator and maintained at a temperature between 33°F (1°C) and 38°F  
(3°C).  
The food product is rethermed just prior to the required meal service in bulk or individual portion.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description ]  
[ Page 2 ]  
Chill Processing Under-Counter and Reach-In Refrigerator/Storage Cabinet  
CCBC-4-35  
The CCBC-4-35 is ideal for food service operations, which require a small volume blast chiller. This  
model is capable of chilling 35 lbs. of food product to 38°F in approximately 90 minutes. Daily capacity  
is over 140 lbs. Of processed product.  
The comprehensive control panel features built in-alarms and can control the chilling process with the  
food core temperature probe or the digital timer.  
At the end of the blast chill cycle the cabinet automatically reverts to a 38°F storage refrigerator.  
CCBC-12-75 & CCBC-12-UA – 100  
The CCBC-12-75 and CCBC-12-UA-100 are ideal for small to medium size food service operations,  
which require a blast chilling capability. The CCBC-12-75 is capable of chilling 75 lbs. of food product  
to 38°F in approximately 90 minutes. The daily capacity is over 300 lbs. of processed product. The  
CCBC-12-UA-100 is capable of chilling 100 lbs. of food product to 38°F in approximately 90 minutes.  
Daily capacity is over 400 lbs. of processed product  
The comprehensive control panels feature built-in alarms and can control the chilling process with three  
food core temperature probes or the digital timer.  
At the end of the chill cycle the cabinet automatically reverts to a 38°F storage refrigerator.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description ]  
[ Page 3 ]  
CCBC-4-35 Chill Temp Blast Chiller  
Standard Features:  
Stainless Steel Exterior and Interior  
Two Operational Features:  
-
-
Blast Chill Processing Refrigerator  
38°F Storage Refrigerator  
Operational Indicator Panel with Microprocessor:  
-
-
-
-
-
-
Blast Chill Cycle Controlled Automatically by Either a Food Probe or Digital Timer  
Four (4) Preset Chilling Times: 30, 60, 90, and 240 minutes  
Cabinet Temperature Digital Display  
Food Temperature Digital Display  
Defrost Mode Indicator  
On/Off, Blast Chill Cycle and Cancel Buttons  
Power Failure Alarm  
Stainless Steel Top, Front, Sides, Door and Interior  
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description ]  
[ Page 4 ]  
Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door  
Gaskets  
Four (4) Pairs of Adjustable Panslides for 12" x 20" x 2 1/2" Pans  
Heavy Duty Casters  
Hot Gas Condensate Vaporization  
Large Surface Area Evaporator and High Velocity Fan  
CFC Free R-134A Refrigerant  
SPECIFICATIONS  
Capacity (lbs/90 mins)  
Width  
Depth  
Open Door Depth  
Height  
ELECTRICAL DATA  
Voltage  
Amperage  
Feed Wires & Ground  
*10 Ft. Cord Installed  
*Requires dedicated 15Amp. Service  
35 lbs.  
28"  
32"  
58 3/4"  
34.5"  
208/230V - 60/1  
7
2
NEMA 6-15P  
Clear Door Width  
Clear Door Height  
Number Of Tray Slides  
REFRIGERATION DATA  
R134a refrigerant  
Compressor HP  
BTU/HR  
21 1/4"  
15"  
4 Sets (2ea)  
WEIGHT  
Crated  
Uncrated  
CRATED DIMENSIONS  
Width  
Depth  
275 lbs  
265 lbs  
3/4 HP  
3,706  
31"  
34"  
39"  
100°F Ambient  
Evaporating@+5°F  
Height  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description ]  
[ Page 5 ]  
CCBC-12-75 Reach-In Blast Chill  
Standard Features:  
Stainless Steel Exterior and Interior  
Two Operational Features:  
-
-
Blast Chill Processing Refrigerator  
38°F Storage Refrigerator  
Operational Indicator Panel with Microprocessor:  
-
Blast Chill Cycle Controlled Automatically by Either Food Probes or Digital  
Timer  
-
-
Four (4) Preset Chilling Times: 30, 60, 90, or 240 Mins.  
Cabinet Temperature Digital Display  
- Defrost Mode Indicator  
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description ]  
[ Page 6 ]  
-
-
Power Failure Alarm  
Three (3) Food Probes with Digital Temperature indicator  
Seven (7) Day Temperature Recorder with Printout Demand  
Stainless Steel Front, Sides, Door and Interior  
Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door Gaskets  
Twelve (12) Pairs of Adjustable Panslides on 3 1/2" Centers for 18" x 26" Sheet Pans  
Six (6) Wire Racks.  
Heavy Duty Swivel Casters with Locking Brakes on the Front  
Condensate Disposed of Automatically  
Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Service  
Compartment  
Automatic Defrost  
CFC Free R-134A Refrigerant  
SPECIFICATIONS  
Capacity  
Width  
Depth  
Open Door Depth  
Height  
Clear Door Width  
Clear Door Height  
Number Of Tray Slides  
Number of Wire Racks  
REFRIGERATION DATA  
Compressor HP  
BTU/HR  
ELECTRICAL DATA  
Voltage  
Amperage  
Feed Wires & Ground  
*10 Ft. Cord Installed  
*Requires separate 20Amp. Service  
WEIGHT  
Crated  
Uncrated  
75 lbs.  
35 1/2"  
32"  
208/230V 60/1  
15  
2
58 1/4"  
77 1/2"  
18 1/4"  
48 1/2"  
12 Sets (2ea)  
6
NEMA 6-20P  
598 lbs  
548 lbs  
CRATED DIMENSIONS  
1.5 HP  
7,188  
Width  
Depth  
Height  
37 1/2"  
38"  
100°F Ambient  
Evaporating @ +5°F  
79"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description ]  
________[ Page 7 ]  
The CBBC-12-UA-100 Reach-In Blast Chiller  
Standard Features  
Stainless Steel Exterior and Interior  
Two Operational Features:  
-
-
Blast Chill Processing Refrigerator  
38°F Storage Refrigerator  
Operational Indicator Panel with Microprocessor:  
Full Microprocessor Controlled by a Digital Timer  
-
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 1-Description_]  
___  
____[ Page 8 ]  
-
-
-
-
On/Off Switch with Blast Cycle and Cancel Button  
Digital Temperature Display and Defrost Indicator  
Power Failure Alarm  
Food Probe with Digital Temperature Indicator  
Galvanized Stee1 Top Stainless Steel Top, Front, Sides, Door and Liner  
Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic; Gaskets  
Twelve (12) Adjustable Universal Angles  
Heavy Duty Swivel Casters with Locking Brakes on the Front  
Automatic Defrost  
Condensation Disposed of Automatically  
Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Compartment  
CFC Free R-404A Refrigerant  
SPECIFICATIONS  
Capacity  
Width  
ELECTRICAL DATA  
Voltage  
Amperage  
100 lbs.  
47"  
39 3/8"  
208/230 - 60/3  
15.5  
2
Depth  
Feed Wires & Ground  
Height  
84"  
Number Of Tray Slides  
12 Sets (2ea)  
WEIGHT  
Crated  
Uncrated  
659 lbs  
648 lbs  
REFRIGERATION DATA  
R404A refrigerant  
Compressor HP  
BTU/HR  
CRATED DIMENSIONS  
2 HP  
10,400  
Evaporating@+5°F  
Width  
Depth  
Height  
47"  
39.375"  
84"  
100°F Ambient  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 9]  
Control Panel For  
CCBC-4-35  
1. Select Chill Mode  
2. Select Hard or Soft Blast  
3. Select Timer for probe or time of process  
4. When satisfied with selections, press Check to Start Cycle  
Probe Temperature Displayed  
5. Press if you want to erase and start  
programming over  
Cabinet Temperature or "DEF" when in Defrost cycle  
Control Panel For  
CCBC-12-75 & CCBC-12-UA-100  
1. Select Chill Mode  
2. Select Hard or Soft Blast  
3. Select Timer for probe or time of process  
4. When satisfied with selections, press Check to Start Cycle  
Probe Temperature Displayed  
Cabinet Temperature or "DEF" when in Defrost cycle  
5. Press if you want to erase and start  
programming over  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 2-Installation ]  
UNPACKING INSTRUCTIONS  
[ Page 10 ]  
IMPORTANT:  
It is highly recommended that your refrigerator or freezer be installed by an authorized  
CresCor Service Agency (List enclosed)  
A. Receiving Shipment  
Upon arrival, examine the exterior of the shipment packaging for any signs of rough  
handling.  
If the cabinet is damaged, it should be noted on the delivery slip or bill of lading and signed  
to that effect. A claim must be filed immediately against the carrier indicating the extent  
and estimated cost of damage incurred.  
All units are performance tested and thoroughly inspected prior to shipment. Upon leaving the  
factory all units are in perfect condition and the carrier signs to this effect.  
B. Uncrating Procedure  
WARNING:  
DO NOT, Under any Circumstances, Lay Your New Equipment Down on Either The Back,  
Front, or Sides!!!  
1. Check for any instructions printed on shipping carton.  
2. Remove protective cardboard corners, sides and top.  
3. Next remove the shipping skid.  
4. If any concealed damage is discovered at this time, notify the carrier in writing, and  
retain all carton and packing materials until an inspection has been made or waived  
by the carrier. Taking a photo of the damage is recommended.  
CAUTION:  
Exercise extreme caution when removing the wooden skid.  
5. Please Note the Model and Serial Number located on the inside right hand wall of the unit.  
Please take the time to write these numbers down and keep in a safe place. A space has been  
supplied for this purpose on the last page of this manual. This will assure you quality service  
and support in the future. Also take the time to register your equipment to activate the  
warranty.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 2-Installation ]  
[ Page 11 ]  
C. Removing Plastic Film  
Stainless steel surfaces are protected with plastic film when shipped. The film is easily removed  
by grasping an edge corner of the film and pulling it off.  
D. Locating Your new Blast Chill Unit  
The cabinet should not be placed in the immediate vicinity of ranges, ovens and other heat  
radiating equipment. This will help to increase efficiency as well as lower operating costs. Self-  
contained refrigeration is standard on reach-in chillers. Adequate air ventilation is mandatory  
for the condensing unit in order to operate efficiently and to prevent excessive and damaging  
operating temperatures. The Blast Chiller should be in an ambient room temperature of 85° or  
less.  
E. Leveling  
The cabinet must be standing level on all four casters for the self-closing doors to operate  
properly and for proper drainage of condensation from the evaporator. Casters are non-  
adjustable, therefore the floor must be level.  
F. Cleaning (refer to section 4)  
G. Electrical Supply  
All models (except the CCBC12-UA-100) are furnished with an electrical power cord & NEMA  
plug, merely requiring that the appropriate NEMA receptacle is available at the installation  
location. Model CCBC12-UA-100 requires a qualified electrician to furnish and install wiring  
for the power supply. This must be connected to the identified terminals provided inside the  
control panel. Refer to the appropriate wiring diagram furnished with the cabinet for guidance.  
Electrical power of the current voltage, phase and ampacity must be supplied to the Blast Chiller.  
The Chiller must have its own separate electrical circuit breaker with no other equipment or  
appliance connected to that breaker. (Dedicated Circuit) See the cabinet data plate located on the  
interior wall for the electrical requirements.  
CHECK LIST (WITH POWER TURNED OFF)  
***** EXAMINE THE FOLLOWING BEFORE START-UP! *****  
CAUTION: Make sure the power to chiller is turned off prior to making  
these checks to avoid the possibility of unexpected injury !!!  
1.  
Check that above installation recommendations have been adhered to. Pay particular  
attention to installation location for any potential excessive heat sources (oven, range,  
etc.) or inadequate air ventilation conditions which can cause compressor overheating  
problems and/or failure. If any such condition exists notify the owner to have the installer  
correct before continuing.  
2.  
Check refrigeration tubing for damage and that they are not touching or rubbing against  
anything.  
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 2-Installation ]  
[ Page 12 ]  
3.  
Make sure cabinet is sitting level with all four (4) casters (or legs) in contact with the  
floor.  
4.  
5.  
Also make sure the door stays open when opened past 90 degrees.  
Inspect magnetic door gasket to be sure it is making contact on all four (4) sides. Also  
make sure it is not cut, torn, twisted or otherwise deformed.  
6.  
7.  
Check installation of shelves or pan slides .  
Check electrical power source for correct voltage, phase and ampacity. Refer to cabinet  
data plate for requirements.  
8.  
9.  
Remove electrical control box cover and check all wiring connections for a secure hold.  
On rare occasions, rough shipping and handling conditions can result in loosening of  
connections resulting in electrical problems.  
Make sure all miniature circuit breakers are turned on.  
10.  
11.  
Check all fan blades. They should turn freely without touching anything as they spin.  
Check electrical power supply cord and plug for any damage and be sure it is not routed  
in a way that would permit anyone to trip over it.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 3-Operation ]  
[ Page 13]  
GENERAL OPERATION OF BLAST CHILLER  
All CRESCOR BLAST CHILLERS have 3 basic modes:  
1.  
Normal refrigeration storage 1°C/34°F to 3°C/38°F  
2.  
3.  
Blast chill hard –10°C/14°F  
Blast chill soft 1°C/34°  
Normal Cycle 1°/34°F to 3°C/38°F  
This is the storage temperature at which the food can be held.  
Blast Chill Cycle (hard or soft)  
During the blast chill hard cycle the air temperature inside the cabinet should go down to  
approximately -10°C/14°F. This is for the timed or probe chilling cycle. Most applications will  
use the hard cycle mode. During soft chill the air temperature stays above 0°C/32°F.  
START UP INFORMATION  
After you have completed all eleven (11) steps of the checklist, you are now ready to perform the  
following steps:  
1. Sanitize the inside of the cabinet and probes.  
2. Turn on BLAST CHILLER left standby button-Display panel will indicate cabinet  
temperature.  
3. There may be an indicator “A7”. This indicates that there has been a power failure.  
4. Press the red “x” cancel button to cancel alarm.  
5. Allow the cabinet to chill in standard refrigerator mode for at least 30 minutes.  
6. Run BLAST CHILLER (See HOW TO OPERATE below) without food product to  
ensure all equipment is performing correctly. Use warm pans of water and place  
probe tips in water to make sure the system is operating.  
Do not submerge probes!  
HOW TO OPERATE  
The following instructions apply to all modes of CRESCOR BLAST CHILLERS  
1. Turn on the chiller at least one half hour before use.  
2. Check that the chiller is operating at storage temperature. Cabinet temp should be  
40°F or lower.  
3. Load the products to be chilled (see Loading Section page 4)  
4. By pressing button ‘1’, select the ‘Chill’ mode  
5. By pressing button ‘2’, select the desired blast function: "Hard Blast" or "Soft Blast".  
( Use Hard Blast unless otherwise advised.)  
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 3-Operation ]  
[ Page 14 ]  
6) By pressing button ‘3’, select the Timer for the desired duration or probed blast. Default to  
probe blast unless it is known how long a product will chill.  
7) If a variety of products are used make sure one probe is strategically placed near the top  
shelf, 1 in the center and 1 at a lower shelf. If a variety of products are used make sure one  
probe is in the largest item to be chilled. Place the CCBC-4-35 probe in the most difficult  
to chill item located on shelf 2 or 3.  
8) When you are happy with your selected program press the "D" to start the blast cycle.  
9) If you are not happy with your selection press the "x" button to cancel your 1/2/3. If  
cancelled repeat the above steps.  
10) The blast chilling will begin.  
TIP: You may open the door during blast chilling. This will not interrupt the cycle. If you add  
additional food product make sure to use an Unused Clean probe in the product.  
On completion of the blast chill cycle, when the product has reached 37°F, a buzzer will sound,  
and “DEF” will be displayed in the “CABINET TEMP” window of the control panel. “DEF”  
indicates the unit is defrosting. The blast chiller converts to a standard refrigerator.  
During the defrost operation the temperature in the chiller will not exceed +3°C/38°F and it is  
therefore safe to leave products in the chiller during the defrost cycle.  
NOTE: Product can be set for blast chilling at the end of the labor shift. The products will store  
safely in refrigeration hold mode until the next shift up to 24 hours.  
BLAST CHILL CYCLE/MODES  
All BLAST CHILLERS allow the operator to use any of the 4 pre-programmed timed cycle and  
a probe control blast chilling cycle with the option of soft or hard blast.  
PROBE CONTROLLED  
The probe blast chill cycle functions with the internal probe(s) supplied. The probe monitors the  
core temperature of the food and will not permit the blast cycle to stop until the default  
temperature of 3°C/38°F is reached. The last product to reach 3°C 38°F will discontinue the  
blast chill cycle.  
When controlling the cycle with the food probe, make certain that the probe or probes are located  
in the center of the product before the blast cycle is started. On BLAST CHILLERS equipped  
with three food probes the cycle will not finish until all three probes have reached the correct  
temperature.  
CAUTION:  
Easier to chill items may actually freeze prior to the end of the blast chill cycle of the harder to  
chill item.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 3-Operation ]  
[ Page 15]  
To activate a blast chill cycle you must:  
1.  
2.  
Choose the required store mode with button 1  
Choose the require blast type with button 2  
(select hard blast unless all items chilling are delicate)  
Choose the blast duration or probe with button 3  
3.  
(select probe unless you know how long it takes the product to chill)  
As each selection is made the indicator LED will illuminate to show what is chosen.  
Press the “D”to accept, or “x” to cancel.  
At the end of the blast chill cycle there will be an audible alarm, which will cancel automatically  
after 15 minutes. (It may also be cancelled with the “x” button.)  
After the blast chill cycle the cabinet will revert to a standard refrigeration mode appropriate to  
store the foods until ready to use or transfer.  
LOADING OF PRODUCT  
1. All food products should be placed in either a 2-1/2” hotel pan or a sheet pan.  
2. With the exception of roasted meats, all products should not be more than 2” in depth.  
1-1/2” is recommended for very dense items such a lasagna and beef stew.  
3. There should not be more than 7 lbs. of product per shelf.  
4. Roast meats should be cut in ½ or 1/3 to allow for more effective chilling.  
5. All Products should be blast chilled uncovered unless a “skin” may be formed (in  
cream soups and sauces).*  
6. Creamed soups and sauces should be covered with plastic wrap. The plastic wrap  
should be touching the product to allow quick chilling. *  
7. Probe(s) should be placed in the center of the pan or roast meat.  
DEFAULT MODE  
To save time for repeated identical blast operations, the blast selections are remembered, so  
when 1-2-3 are pressed again, the selections automatically adopt the previous settings on the first  
push. So to repeat a blast chill mode, just push 1 2 3 “D”.  
DEFROST  
At the end of each cycle, the defrost cycle will automatically clear any ice from the evaporator.  
During operation in storage mode a defrost will be performed automatically at the factory pre-set  
interval of 6 hours.  
*see general rules of thumb pg. 30 for more information.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 3-Operation ]  
[ Page 16]  
If a blast cycle is cancelled and the defrost thermostat is measuring 1°C/32°F or less, the BLAST  
CHILLER automatically goes into a defrost cycle.  
When the BLAST CHILLER is in the defrost mode the “Cabinet Temp” window of the control  
panel will display “DEF” During the defrost cycle some fans will stop running. This is normal.  
When the defrost cycle is finished the compressor will run for approximately 90 seconds before  
the fans operate.  
Following every defrost period there is a 3 minute period during which a blast cycle cannot be  
selected. This short interval is to allow for the water created by the defrost mode to dissipate.  
The cabinet is now ready to start another blast cycle if desired.  
During the defrost operation it is safe to leave products inside the blast chiller.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 3-Operation ]  
[ Page 17]  
PRINTER  
If equipped, the printer is activated after each blast cycle. The printer provides hard copy  
historical data of cabinet performance or warning tickets to archive or act upon.  
The following formats are available:  
Midnight Ticket  
At midnight, a ticket is automatically printed for archiving in the morning. The midnight ticket  
provides the following information:  
-
-
-
Time and date of printout and cabinet number  
Cabinet temperature at time of printout  
A graph of cabinet temperature over the preceding 24 hours  
Demand Ticket  
A ticket may be requested from the control panel by holding the printer 'On/Off' button for five  
(5) seconds. This ticket provides the same information as the midnight ticket except that up to  
seven (7) days of historical data are printed.  
Alarm or Warning Ticket  
A ticket is automatically printed if any condition is detected by the microcontroller, which may  
need attention. The print function may be terminated by pressing the printer 'On/Off' button.  
Main Power Failure Ticket  
If the main power fails for more than five (5) seconds a ticket is automatically printed which  
gives the time of power failure and the time at which power is stored.  
Sensor Failure Ticket  
If the controller detects that one of its sensors has failed, then a warning ticket will be printed.  
Power Failure  
A power cut does not cause the loss of any accumulated historical data and no re-programming is  
necessary. The controller's battery is continually charged and provides emergency back up under  
normal power failure conditions.  
Installing New Paper and/or Ribbon  
Paper:  
1. Lift Up and pull Out the printer cover.  
2. Remove old cardboard roll, insert new paper roll in position so paper is fed unrolling from  
the bottom backside.  
3. Fold paper end into a V shape and thread it through the slot over the ribbon cartridge.  
4. Press "FEED" button on panel....paper should feed through slot, If not, redo step 4 and try  
again until paper feeds through. Check for proper operation.  
Ribbon:  
To Remove:  
Hold ribbon cartridge between thumb and pointer finger, pull gently but firmly out (towards you)  
To replace:  
Snap new cartridge in place and re-feed paper. Check for proper operation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 4- Maintenance ]  
[ Page 18 ]  
CAUTION !  
HINTS:  
1. Turn Off Blast Chiller  
1. Use the mildest cleaning product that will  
do the job  
2. Always rub in the direction of polish lines to  
Avoid scratching the surface.  
2. Allow Cabinet to warm slightly.  
3. Do not hose Blast Chiller.  
Wipe up spills as soon as possible.  
Clean regularly to avoid heavy dirt buildup.  
3. Use only a soft cloth, sponge, fibrous brushes,  
Plastic pads for cleaning and scouring.  
4. Rinse thoroughly with fresh water after every  
Cleaning operation.  
5. Always wipe dry to avoid watermarks.  
SOIL  
CLEANER  
Soap, ammonia or  
METHOD  
Routine Cleaning  
1. Sponge on with cloth.  
2. Rinse.  
detergent* and water.  
Stubborn spots  
and stains  
Mild abrasive made for  
stainless steel.  
1. Apply with damp sponge or cloth.  
2. Rub lightly.  
Probe  
Antibacterial soap,  
ammonia or detergent*  
and water.  
1. Remove excess food from probe.  
2. Clean and sanitize.  
Hard Water Spots  
and Scale  
Vinegar.  
1. Swab or wipe with cloth.  
2. Rinse and dry.  
* Mild detergents include soaps and non-abrasive cleaners.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 5- Troubleshooting ]  
[ Page 19 ]  
SERVICE & TROUBLESHOOTING  
Setting or Resetting Time and Date  
SET UP PROCEDURE  
SWITCH  
FUNCTION IN SPECIAL SWITCH MODE  
I/O  
1
ON/OFF SWITCH  
When held in, displays the code for current parameter  
2
Step back to previous parameter, and while held in displays the parameter  
code. When released, displays the value of the parameter.  
Advance to the next parameter. (same as above)  
3
Increase the value of the current parameter.  
X
Decrease the value of the current parameter  
To set the parameters complete the following steps:  
1. This can only be entered from the panel OFF mode.  
2. Press and HOLD IN any key EXCEPT the ON/OFF key for three seconds.  
3. While Holding key, press and release the ON/OFF key.  
You will now be in the programming mode.  
CODE  
bss  
bhs  
bfs  
sss  
shs  
sfs  
bsd  
bhd  
bfd  
PARAMETER  
SET AT:  
33  
Blast Soft Stat  
Blast Hard Stat  
Blast Freeze Stat  
Store Soft Stat  
12  
-16  
33  
33  
-8  
35  
35  
35  
35  
Store Hard Stat  
Store Freeze Stat  
Blast Soft Differential  
Blast Hard Differential  
Blast Freeze Differtial  
Store Soft Differential  
Store Freeze Differential  
ssd  
sfd  
35  
bd1  
bd2  
bd3  
bd4  
cab  
ala  
Blast Duration 1 (normally 30 min.)  
Blast Duration 2 (normally 60 min.)  
Blast Duration 3 (normally 90 min.)  
Blast Duration 4 (normally 240 min)  
Cabinet Number  
Alarm Duration  
Defrost Duration for Cabinet  
Defrost Interval for Cabinet  
30  
60  
90  
240  
1
900 (15 min)  
Hex. Switch  
Hex. Switch  
ddc  
dic  
ddp  
dip  
det  
N/A defrost Duration for PoD minutes, Set Manually  
N/A defrost Interval Hours, Set Manually  
Defrost Target Temperature  
39  
yr  
nth  
day  
hr  
Calander Year Setting  
Calander Month Setting  
Calander Day Setting  
Calander Hour Setting  
Calander Minute Setting  
Set Accordingly  
Set Accordingly  
Set Accordingly  
Set Accordingly  
Set Accordingly  
ute  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 5- Troubleshooting ]  
ALARM CODES  
[ Page 19a ]  
7-Segment Display  
The left hand window shows the cabinet wall temperature.  
The right hand displays show the probe temperatures during a blast cycle, and are normally blank  
during store. If a probe fails it will indicate pf (probe failure) during a blast.  
Cab temp window also acts as a count up timer in probe blast.  
If there is an alarm condition, the top probe display will show an alarm number a0 to a7  
during store (see table below), but will still show the probe temperature during blast.  
7-Seg Display  
Alarm Condition  
a0  
a1  
a2  
AIR ON SENSOR FAILURE  
WALL SENSOR FAILURE  
FIN SENSOR FAILURE  
a3  
a4  
FOOD PROBE 1 FAILURE *  
FOOD PROBE 2 FAILURE  
a5  
a6  
a7  
FOOD PROBE 3 FAILURE  
SPARE  
POWER CUT DETECTED  
* (Top Display On Front Panel Used For 3 Probe Systems)  
Note: for each probe only one audible alarm and alarm printout is allowed to be issued  
each day. This is to prevent excessive paper use and noise nuisance in the event of an  
intermittent probe failure. However, repeated probe failures are displayed on the probe  
display window, (top window in the case of 3 probe panels)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 5- Troubleshooting ]  
Cabinet has no power to controller-display not lit:  
[ Page 20 ]  
1. Make sure the power is connected to the cabinet that the cord is plugged in on the  
models with power cord and plug.  
2. Check main circuit breaker at power supply panel; make sure it is on.  
3. Model CCBC-12-UA-100 only, has an "isolator" (disconnect) switch on the control box,  
make sure it is on.  
4. Check circuit breakers inside cabinet control box; make sure all are on.  
Check control power supply circuit safety klixon (some models). If tripped due to  
having exceeded 158°F, some models must be manually reset by pushing the red reset  
button (make sure power is turned off before doing this to avoid any unexpected  
injury!). Other models will reset automatically.  
5. Check fuse on PC board.  
6. Check for loose wiring.  
7. Check plug in connectors for interconnecting cords and cables from main to front  
"Touch Pad" operators panel.  
8. Defective communications ribbon cable.  
9. Defective main or front PCB.  
Cabinet has power, display shows "OFF". Turn cabinet "on" by pressing "OFF/ON" button.  
1. Compressor not running:  
(a) Manually close compressor contactor (if utilized) temporarily to see if  
compressor runs.  
(b) If compressor runs, check compressor control circuit for problem.  
(1) Is the Dual Pressure Control open?  
-
-
-
Check for correct settings  
Low or no refrigerant charge  
Liquid Line Solenoid Valve (if used) not opening?  
(c) If the compressor doesn't run, check if you have power to compressor  
terminals.  
(1) If no power to terminals, trace back until power is found. Correct  
problem.  
-
If single phase, check start relay and capacitor(s).  
(2) If power is present at compressor terminals, check for stripped  
compressor overload and/or "open" or grounded compressor-motor  
windings.  
2. Compressor does run:  
(a) Compressor short cycles.  
(1) Check DPC settings. Cut-in and/or differential may need to be  
adjusted.  
(2) Check refrigerant charge may be low.  
-
If low, or no charge, check for leaks, repair and recharge as  
necessary.  
(3) Check if thermostatic expansion valve is feeding properly.  
(4) Check Chiller Store Thermostat ("St 1") and Differential ("Dt 1")  
settings.  
(5) Check the "fin" and "air on" thermocouples at main PCB to make sure  
they are not interchanged.  
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 5- Troubleshooting ]  
[ Page 21 ]  
3. Compressor runs continuously.  
(1) Check compressor for "pumping" efficiency.  
(2) Door not closed tight or gasket leaking.  
(3) If no DPC, or if DPC set too low to open, check refrigerant charge  
and/or thermostatic expansion valve for adequate feeding.  
Cabinet has power, display shows "Sto", but load of hot food takes extremely long to chill:  
1. "Sto" is the storage mode and cannot chill food properly. You must first choose a  
"PROGRAM" and then press "BLAST" in order to make the machine do a blast chill  
cycle to quickly chill hot food.  
In "BLAST" mode, unit runs, but doesn't chill the food fast enough.  
1. Food too "thick" - limit 2 inches maximum for optimum performance.  
2. Food too hot when placed inside - temperatures above 160°F increase pull-down time  
proportionally.  
3. Too much food - exceeding rated pounds of capacity increases pull-down time  
proportionally.  
4. Food covered (air trapped between food and cover is and insulator).  
5. Container too large (distance from outside of container to center of food within is too  
great, shouldn’t exceed 2 inches for optimum performance).  
6. Container material is plastic (an insulator) instead of metal (a conductor).  
7. If cabinet was off did not pre-chill before loading with hot food.  
8. If using timed program, incorrect amount of time being selected.  
9. Mechanical problem:  
(a) Inadequate refrigerant charge.  
(b) Thermostatic Expansion Valve defective.  
(c) Evaporator fan(s) not working.  
(d) Evaporator coil iced (see below for possible causes).  
(e) Inadequate refrigeration (BTUH) capacity:  
-
-
-
-
-
Condensing unit ambient, or too high  
Condenser fan not working (if air cooled)  
Condenser dirty  
Compressor inefficient (or defective)  
Refrigerant line restriction  
Evaporator coil iced:  
1. Check how cabinet is being operated:  
(a) Placing load of hot food inside and merely closing door is improper use.  
Doing this keeps unit in the storage ("Sto") mode resulting in extremely long  
pull-down times and does not initiate an automatic defrost. As a result the  
evaporator coil becomes heavily iced.  
(b) Must run a "BLAST" cycle for automatic defrosting to occur.  
(continued)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Section 5-Troubleshooting ]  
[ Page 22 ]  
2. Door not shut tight  
3. Gaskets leaking  
4. Check defrost heater operator (if used):  
(a) Defective heater  
(b) Blown fuse (if used)  
(c) Defective "klixon" if used  
5. Check defrost settings:  
(a) Check defrost thermostat ("St 5") setting  
(b) Check defrost differential ("dt 5") setting  
(c) Check Defrost Period Switch on main PCB inside control box  
(d) Check Defrost Length Switch on main PCB control box.  
6. Check that ambient temperature has not exceeded 100°F or 100% humidity.  
Display reads - 58° F  
1. Thermocouple is "open" :  
(a) If food probe, check the make sure it's plugged into probe receptacle properly  
(b) Check for loosened thermocouple wire connection at all connections  
(c) Check for broken or cut thermocouple wire  
(d) Temperature display not believable - responds in reverse:  
-
Polarity of thermocouple wire is reversed  
Evaporator won't run:  
1. Breaker not on (if equipped)  
2. Motor overload tripped (if equipped)  
3. In post-defrost "Drip" period  
4. "Fan door" switch is open (if equipped)  
5. Blown fuse (if used)  
6. Defective contactor (if equipped)  
7. Motor defective  
Printer problems (if equipped) :  
1. Printer doesn't run:  
(a) "Link" (jumper) on main PCB not installed  
(b) Damaged communications "ribbon" cable  
(c) Defective printer  
(d) Defective PCB  
2. Printer "runs", but no paper comes out:  
(a) Check if paper roll is loaded  
(b) Check for jammed paper tape -  
-
Before loading a new roll, make sure free end of tape is pulled  
completely away from the roll. Remove any paper residue. (The  
residue will undoubtedly result in a paper jam).  
Carefully remove any paper residue from printer platen, otherwise  
another jam could occur.  
-
(c) Check for proper tape feed  
3. Printer runs, but paper comes out with no printing:  
(a) Check if printer has ribbon cartridge installed  
(b) Check ribbon - condition may be out of ink, dried out, or torn  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 5-Troubleshooting ]  
[ Page 23 ]  
(c) Check make sure ribbon cartridge is properly installed - both sides snapped in  
place  
4. Printer is printing backwards and all characters reversed  
(a) Paper tape is feeding incorrectly over top of printer ribbon. This can readily  
occur when inserting a ribbon cartridge with paper tape still protruding from  
the printer. The ribbon must be on top of the paper in order to print  
correctly.  
5. Paper rolls and ribbon cartridges are available from CresCor Authorized Parts  
Distributors.  
Odors inside cabinet:  
1. Spilled food inside - clean as required  
2. If not being used for a long period of time, turn off, clean interior and keep door open  
to ventilate. Alternatively after cleaning, place and odor absorbent such as baking  
soda inside with the door kept closed. Remove before restarting.  
Alarm conditions:  
1. Cabinet wall temperature above 38°F more than 60 minutes  
2. Defrost termination on time instead of temperature  
3. Compressor overheating (if temperature is greater than 217°F for 1 minute)  
4. Compressor run (if the compressor runs continuously for more than 6 hours in either  
blast mode or storage mode)  
5. Faulty sensor (including food probe)  
6. Loss of power for 5 seconds or more  
7. Dead battery  
Food dried out  
1. Uncovered containers  
2. Left in storage too long  
Food frozen  
1. Too long blast cycle  
(a) Choose a shorter timed program  
(b) Use the probe program  
2. Uneven food portions-thinner foods can freeze by the time thicker portions reach  
temperature  
3. Monitor temperatures more frequently if uneven food loads and remove those when  
reaching end temperature  
4. Food probe defective  
5. Stat 1 set too warm  
Food not cold enough  
1. Timed cycle too short  
2. Stat 1 set too warm  
3. Food probe tip not in center of food  
4. Defective probe  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Section 6 – Parts and Drawings ]______________________ __  
[ Page 24 ]  
Parts List and Breakdown Drawing of Blast  
Chillers  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 25 ]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 26 ]  
PARTS LIST CCBC-4-35 BLAST CHILLER 208V 60HZ SINGLE PHASE  
Drawing Number  
Description  
Part Number  
1
1a  
1b  
1c  
2
COMPRESSOR CAJ 4492Y R134A  
CONDENSER 3X11X21  
WCOMP 345  
WCOND 250  
DRIER 1/4 X 3/16 SWEAT T R134A  
SIGHT GLASS 1/4" SWEAT  
RECEIVER 2.2 L  
WDRIER 110  
WSIGHT 020  
WRECEIVER 060  
WVALVE 196  
3
EXPANSION VALVE BODY TEN 2 R134A  
1/4" SOLDER ADAPTOR  
3
WVALVE 198  
3
ORIFICE NO. 3  
WVALVE 201  
4
CONDENSOR FAN MOTOR 16 WATT  
CONDENSOR FAN BLADE 10" 27° PITCH  
CONDENSOR FAN PLATE  
WMOTOR 270  
4
WBLADE 070  
5
WCFP/WBC35/99/1  
WMOTOR 420  
6
EVAPORATOR FAN 315MM AXIAL FAN (ZIEHL EBM)  
EVAPORATOR WIRE FAN GUARD 50MM DEEP  
EVAPORATOR FAN PLATE  
RACKING  
7
WGUARD 090  
8
WEFP/WBC35/99/1  
WLR/WBC35/99/1  
WPROBE 100  
9
10  
10a  
11  
11a  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
23  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
FOOD PROBE  
FLANGED SOCKET  
WPROBE SOCKET 010  
WUCT/WBC35/99/1  
WUCB/WBC35/99/1  
WGASKET 905  
WHINGE 020  
UNIT COVER (TOP)  
UNIT COVER (BOTTOM)  
GASKET: 680MM X 430MM  
HINGE PLATE: R7 OPAL-TOP  
HINGE: SPRING LOADED  
WHINGE 290  
STANDARD DOOR  
WWBC35 STD DOOR/99/1  
WEVAP 485  
EVAPORATOR 4X13X17  
DRIP TRAY  
WDT/WBC35/99/1  
WHEATER 030  
WDOOR NYLON NEW  
WLADDERACK 020  
WSCREW 140  
DEFROST HEATER 3 BEND 300W  
NEW DOOR NYLON  
LADDERRACK MOUNTING BLOCK  
SCREW: M6 X 12 POZI PAN ZINC T/T  
WBC/SPEC B1 WITHOUT PT. NO 4253  
AARDWARE FRONT PANEL  
AARDWARE BACK BOARD NO PRINTER  
1M RIBBON TO CONNECT TO FRONT & BACK  
LEGS: S/S 4" SHORT STUD C/C PLATE  
KLOCKNER MOELLER DIL 00M 190V 50HZ/220V 60HZ  
6MM X 25MM ZINC POZI PAN TAP TIGHT SCREWS  
S/S/ SLIDE 585MM (2 OFF PER SLIDE 276MM)  
LATCH: UNIT COVER (CLIP)  
STRIKE: UNIT COVER (CLIP)  
8MM X 20MM ZINC SET SCREWS  
REAR COVER  
WLABEL 701  
WAARDWARE 010  
WAARDWARE 030  
WLOGGER RIBBON 010  
WLEG 050  
WCONTACT 190  
WSCREW 180  
WS/SLIDE 06O  
WLATCH 030  
WSTRIKE 010  
WSCREW 585  
WRC/WBC35/99/1  
WHGV/335X185/88/1  
WPLUG 170  
HOT GAS VAPORIZER  
PLUG  
34  
35  
CORD  
WCABLE 520  
WLADDERACK 010  
LADDERRACK MOUNTING BLOCKS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 27 ]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 28 ]  
PARTS LIST CCBC-12-75 BLAST CHILLER 208V 60HZ SINGLE PHASE  
Drawing Number  
Description  
Part Number  
1
1
COMPRESSOR FH4518Y 208/220V 60HZ  
CONDENSER 4X17X17.5  
EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL  
FLAT GUARD  
WCOMP 365  
WCOND208  
3
WFAN 115  
3
WGUARD 080  
3
1.5 UF CAPACITOR 230V 60HZ  
EVAPORATOR 4X12X41  
WCAPACITOR 050  
WEVAP311  
4
5
SIGHT GLASS 3/8" SWEAT  
DRIER 3/8" SUITABLE FOR H134A  
EXPANSION VALVE TEN 2 R134A  
3/8" SOLDER ADAPTOR 068-2060  
ORIFICE NO. 3  
WSIGHT 010  
6
WDRIER 080  
7
WVALVE 196  
7
WVALVE 197  
7
WVALVE 231  
8
DEFROST HEATER 2X500 WATT 1 BEND  
VAPORIZER HEATER 115 WATT 3 BEND  
HEATER WIRE 4.35M 240V (57 WATT)  
KLIXON 14T31 30210 L13C 9651  
FOOD PROBE  
WHEATER 400  
WHEATER 010  
WHEATER WIRE 340  
WSTAT 410  
9
10  
11  
12  
13  
14  
14  
14  
14a  
15  
16  
17  
18  
19  
19a  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
WPROBE 1OO  
PROBE SOCKET  
WPROBE SOCKET 010  
WAARDWARE 020  
WAARDWARE 010  
WAARDWARE RIBBON 020  
WLABEL 746  
AARDWARE FRONT PANEL C/W PRINTER  
AARDWARE BACK BOARD  
1.5M RIBBON TO CONNECT TO FRONT & BACK  
LABEL: 3 PROBE F°  
HIGH / LOW PRESSURE STAT  
NEW DOOR NYLON  
WSWITCH 360  
WDOOR NYLON NEW  
WHINGE 290  
HINGE: SPRING LOADED  
SWITCH: THERMAL HEATED 331-528  
CASTOR 6" W/BRAKE  
WSWITCH 200  
WCASTOR 040  
WCASTOR 030  
WHINGE 070  
CASTOR 6" NO BRAKE  
HINGE PLATE: R4 OPAL/T2U  
LADDERACK BLOCKS  
WLADDERACK 020  
WUC/WBC75/99/1  
WCP/WBC75/99/1  
WWBC75 STD DOOR/99/1  
WGASKET 900  
WLR/WBC75/99/1  
WDT/WBC75/99/1  
WBP/WBC75/99/1  
WEFP/WBC75/99/1  
WEBP/WBC75/99/1  
WCFP/WBC75/99/1  
WBIGHEAD 010  
WSCREW 200  
UNIT COVER  
CONTROL PANEL  
DOOR  
GASKET 1295MM X 565MM  
LADDERACK (1SET)  
DRIP TRAY  
BAFFLE PLATE  
EVAPORATOR FAN PLATE  
EVAPORATOR BAFFLE PLATE  
CONDENSER FAN PLATE  
BIGHEAD M/4T38 6X26  
SCREW M6X25 POZI COUNTERSUNK  
SCREW M6X25 POZI PAN ZINC T/T  
ELECTRIC VAPORIZER  
WSCREW 180  
WEV/800X235/88/l  
WMOTOR 410  
CONDENSOR FAN 120W MOTOR  
3.0 UF CAPACITOR 230V 60HZ  
CONTROL PANEL BOTTOM  
HINGE: BLACK PLASTIC  
KLOCKER MOELLER DIL OM 190V 50HZ/220V 60 HZ  
RECEIVER 2.2 LT  
WCAPACITOR 060  
WCPB/WBC75/99/1  
WHINGE 560  
WCONTACT 160  
WRECEIVER 060  
WBIGHEAD 060  
WPLUG 160  
BIGHEAD 316-F2/ST38 M5X5  
MAINS PLUG  
MAINS LEAD  
WCABLE 510  
LINER BASE  
WS/SBASE 180  
WTS/WBC75/99/1  
WCPRC/WBC75/99/1  
TRAY SLIDE  
CONTROL PANEL REAR COVER  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 29 ]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 30 ]  
PARTS LIST CCBC-12-UA-100 BLAST CHILLER 208V 60HZ 3 PHASE  
Drawing Number  
Description  
Part Number  
1
2
COMPRESSOR TFH 4524Z 208/230V 60HZ  
CONDENSER 4X17X17.5  
WCOMP 833  
WCOND208  
3
EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL  
FLAT GUARD  
WFAN 115  
3
WGUARD 080  
3
1.5 UF CAPACITOR 230V 60HZ  
EVAPORATOR 5X45X16  
WCAPACITOR 040  
WEVAP348  
4
5
SIGHT GLASS 3/8" SWEAT  
DRIER 3/8"  
WSIGHT 010  
6
WDRIER 080  
7
EXPANSION VALVE TES 2 R404A  
3/8 SOLDER ADAPTOR 068-2060  
ORIFICE NO. 3  
WVALVE 191  
7
WVALVE 197  
7
WVALVE 231  
8
DEFROST HEATER 2X500 WATT 1 BEND  
VAPORIZER HEATER 115 WATT 3 BEND  
HEATER WIRE 4.35M 240V (57 WATTS)  
KLIXON 141T31 30210 L13C 9651  
FOOD PROBE (3 EACH)  
WHEATER 500  
9
WHEATER 010  
10  
11  
12  
13  
14  
14  
14  
14  
14a  
15  
16  
17  
18  
19  
19a  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
WHEATER WIRE 340  
WSTAT 410  
WPROBE 1OO  
PROBE SOCKET  
WPROBE SOCKET 010  
WAARDWARE 070  
WAARDWARE 040  
WLOGGER CHIP 170  
WAARDWARE RIBBON Sm  
WLABEL 918  
AARDWARE FRONT PANEL C/W PRINTER  
AARDWARE BACK BOARD  
LOGGER CHIP  
1.M RIBBON TO CONNECT FRONT & BACK  
NEW BLAST CHILL 3 PROBE C/W PRINTER  
HIGH / LOW PRESSURE STAT  
NEW DOOR NYLON  
WSWITCH 360  
WDOOR NYLON NEW  
WHINGE 290  
HINGE: SPRING LOADED  
SWITCH: THERMAL HEATED  
CASTOR 6" W/BRAKE  
WSWITCH 200  
WCASTOR 040  
CASTOR 6" NO BRAKE  
WCASTOR 030  
HINGE PLATE: R4 OPAL/T2U  
LADDERACK BLOCKS  
WHINGE 070  
WLADDERACK 020  
WUC/WBC1I0/99/1  
WCP/WBC1I0/99/1  
WWBC110 STD DOOR/99/1  
WGASKET 895  
UNIT COVER  
CONTROL PANEL  
DOOR  
GASKET: 1354MM X 627MM C/C  
LADDERACK (1SET)  
WLR/WBC110/99/1  
WDT/WBC110/99/1  
WBP/WBC110/99/1  
WEFP/WBC110/99/1  
WEBP/WBC110/99/1  
WCFP/WBC110/99/1  
WBIGHEAD 010  
WSCREW 200  
DRIP TRAY  
BAFFLE PLATE  
EVAPORATOR FAN PLATE  
EVAPORATOR BAFFLE PLATE  
CONDENSER FAN PLATE  
BIGHEAD M/4T38 6X26  
SCREW M6 X 25 POZI COUNTERSUNK  
SCREW M6 X 25 POZI PAN ZINC T/T  
ELECTRIC VAPORIZER  
WSCREW 180  
WEV/800X235/88/l  
WMOTOR 410  
CONDENSER FAN 120W MOTOR  
CONTROL PANEL BOTTOM  
HINGE: BLACK PLASTIC  
WCPB/IWBC/110/99/1  
WHINGE 560  
KLOCKER MOELLER DIL OM 190V 50HZ/220V 60HZ  
RECEIVER 3.3 LT  
WCONTACT 160  
WRECEIVER 070  
WBIGHEAD 060  
WCFC/WBC110/99/1  
WSLID/WBC110/99/1  
WCPRC/WBC110/99/1  
WTHERM 230  
BIGHEAD 316-F2/ST38 M5X5  
CONDENSER FAN COWL (BEHIND FAN)  
UIVERSAL ANGLES (24 PER CABINET)  
CONTROL PANEL REAR COVER  
THERMOCOUPLE TYPE T PTFE 2M  
SHELF GARNET WHITE COATED (X12)  
WSHELF 185  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Rules of Thumb  
[ Page 31 ]  
Pre-Chill the cabinet for thirty (30) minutes before you do first load.  
(to remove interior residual heat)  
Doubling the food thickness triples the pull-down time.  
Don't stack food or containers on top of or alongside of each other.  
(this increases the "thickness)  
Covering the food increases pull-down time by 10%-30%.  
Pull-down rate initially is about 2°F per minute and approaching final temperature is about 2  
minutes per degree F.  
"A watched pot never boils"  
Factors affecting blast chill pull-down times:  
(A)Initial food temperatures  
(The hotter the initial food temp., the longer the pull-down time)  
(B) Final food temp. (the colder the final temp., the longer the pull-down time)  
(C) Food "thickness"(the greater the distance from geometric "core" center of food to its  
surface, the longer the pull-down time)  
(D)Food density (the greater the density, the longer the pull-down time)  
(E) Container surface area(the smaller the surface area, the longer the pull-down time)  
(F) Container material (metals are conductors which will shorten the length of pull-down  
time, while plastics are insulators which will increase pull-down time)  
(G)Covering material (metal preferred, same reasons as above)  
(H)Covering method (Covering which is in direct contact with the food will pull-down  
quicker than covering that is stretched tight leaving a "dead air" space between cover  
and food. Air acts as an insulator and will increase the pull-down time)  
(I) Amount (weight) of food put in as compared to rated capacity (exceeding rated  
capacity will lengthen the time of pull-down)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contact Information  
[ Page 32 ]  
Please Send Serial registration information to :  
Fax: (800) 378 – 8333  
E-mail to: parts&[email protected]  
Or  
Mail To:  
CresCor  
5925 Heisley Road  
Mentor, OH 44060  
Toll Free: 877-273-7267 Fax: 440-350-7267  
See us online at: http://www.crescor.com  
Questions?  
Call and Speak To One Of Our  
Friendly Service Counselors:  
Ellery @ Ext. 319  
Pat @ Ext. 214  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[ Page 33 ]  
Notes  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
__________________________________________________________  
Date Purchased  
________________  
Date of Installation ________________  
Serial Number  
Model Number  
_________________________  
_________________________  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 34]  
MEATS*  
Roasted Meats  
Roasted meats should be prepared according to the recipe using roast guidelines for each  
product.  
Roast Beef (top round) - Follow recipe and roast guidelines. Recommended  
doneness for rethermalization is about 140° F. (60° C.). Top round should be  
quartered and placed in the blast chiller. If roast beef is used for cold sandwiches,  
the end cooking temperature may be higher. If medium doneness is desired, roast  
to 150° F. (65° C.). Do not overcook.  
Pork Roast - Follow recipe and roast guidelines. Recommended doneness for  
rethermalization is 165° to 170° F. (74° to 76° C.). Do not overcook or product  
will be dry.  
Lamb Roast - Follow recipe and roast guidelines. Recommended doneness for  
rethermalization is 155° F. (68° C.). Do not overcook.  
Proportioned Meats (hamburger patty, pork chop, Salisbury steak, etc.)  
Cook according to recipe. If sauce or gravy is required, it should be prepared and chilled  
separately from the portioned meat.  
Steak (filet, strip, ribeye) - Broil steak to medium rare or preferred stage of  
doneness. Blast chill immediately.  
Salisbury Steak - Bake to 165° F. (74° C.) Drain well, remove all grease. Blast  
chill. Add gravy after steak is chilled.  
Pork Chops/Cutlets - Breaded, baked, or broiled chop is heated only to 165° F.  
(74° C.) and blast chilled immediately. Add sauce or gravy after chilling.  
Turkey/Chicken  
Cook turkey or chicken whole or breasts according to directions to 170° F. (76° C.).  
Blast chill immediately. Slice product to a 1/4" thickness, single layered. Pre-cooked  
turkey products do not require roasting.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 35]  
Seafood  
Fish - Prepare all fish fillets according to recipe for breaded, baked, broiled,  
steamed, etc. Be careful not to overcook. Blast chill immediately.  
Shrimp/Scallops/Shellfish - Prepare according to recipe and blast chill  
immediately. Be careful not to overcook. If prepared with a sauce (creole, etc.),  
cook the sauce separate and mix together prior to retherm.  
Casseroles and Stews  
Stew and casseroles are very successful in cook/chill and rethermalization. Most recipes  
should require little change for cook/chill. Products should be moist but hold form when  
plated. Prepare and blast chill in 2-1/2" full pans.  
Lasagna - Brown off convenience lasagna to remove extra moisture and blast chill.  
Prepared from scratch, follow the recipe; do not overcook. Blast chill.  
Beef Stew/Stroganoff, etc. - Cook/steam meat until tender. Prepare as stated in  
recipe. Blast chill.  
Chicken/Turkey/Beef Pot Pie - Prepare the chicken/turkey/beef and vegetable  
sauce separately from the crust, pastry, or biscuit. Top product after chilling or at  
point of rethermalization.  
Stir Frys – Sauté / steam until meat is done and vegetables are crisp.  
Pasta Casserole (Mac & Cheese, Turkey Tetrazzini) - Prepare sauce separately  
from pasta. Blast chill. Mix product together chilled and rethermed.  
Sauces and Gravies  
For conventionally prepared gravies and sauces, substitute a portion of the flour or  
cornstarch with a modified starch. A substitute of 30 to 50% by weight is recommended.  
In preparing these sauces and gravies with the modified starch, the product must reach  
170° F. (76° C.) and be held at the temperature for a minimum of 5 minutes. If this is not  
done, the gravy or sauce will thicken during the chilled storage. To reduce the risk of  
rancidity during refrigerated storage, use broth bases rather than meat or poultry  
drippings. Commercial gravy or sauce bases contain modified starches and can be  
substituted for conventionally prepared products.  
Sandwiches/Specialty Items  
See CresCor Retherm Oven Time and Temperature chart on Page 60 in CresCor  
cookbook.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 36]  
SOUPS  
Conventional Soup  
Prepare conventionally. For creamed soups, substitute a modified starch for a portion of  
the thickening agent by 30 to 50%.  
Canned Soup  
No cooking is necessary for broth based soups. Cream soups should be diluted with milk  
or water, mixed completely, and blast chilled.  
Frozen Soup  
Follow instructions on the soup container for preparing soup, blend thoroughly, and blast  
chill.  
VEGETABLES  
Add seasonings to vegetables prior to panning. If margarine is added, a more even  
distribution will occur with liquid margarine.  
Frozen Vegetables  
Frozen vegetables do not require cooking before rethermalization.  
For bulk rethermalization, vegetables do not need to be cooked or blast chilled before  
service and should be prepared as in conventional production.  
Canned Vegetables  
Canned vegetables do not require any cooking. All canned vegetables can easily be bulk  
rethermed with little liquid remaining.  
Fresh Vegetables  
Many fresh vegetables can be used in cook/chill. The desired texture of the product will  
determine the preparation procedure.  
Zucchini/Yellow Squash Steam or stir fry to desired consistency then blast chill.  
Broiled Tomato  
Slice in half and sprinkle on topping. Broil to brown topping  
and blast chill immediately. Tomato will continue baking during rethermalization.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 37]  
Broccoli/Cauliflower/Green Beans/Carrots  
Prepare green beans and carrots in  
bite size and broccoli and cauliflower in flowerets. Steam to desired doneness,  
then blast chill.  
Stuffed Vegetables (eggplant, zucchini) Prepare stuffing and blast chill. Steam  
shell and blast chill or place in ice bath. Stuff vegetable shell and blast chill to  
bring temperature down from time of assembly.  
Grilled Vegetables  
Grill according to recipe. Place in 2-1/2" pan and blast chill.  
POTATOES  
Occasionally, "graying" or slight darkening of the cut surfaces of some cooked potatoes  
will occur during chilling. This is an oxidation reaction and varies with the variety of  
potato, soil, and weather conditions. Varieties that most often exhibit darkening are:  
Irish, Ontario, Norland, and Red Pontiac.  
Potatoes are fully cooked before blast chilling. Canned potatoes, well drained, can be  
used without further cooking.  
Mashed Potato (flakes or powder)  
Follow recipe according to the package. Product should be smooth, easy to scoop, and  
hold its form loosely at the point of blast chilling. Product should stay at that consistency  
after blast chilling. If the product becomes stiff or dry, add water and stir into product.  
Mashed Potato (fresh)  
Follow recipe. Potatoes should be very soft before mashing and adding liquid. Follow  
same consistency rule as for flake or powder potatoes. Cover with plastic and blast chill.  
Fresh mashed potatoes should not be made more than 48 hours in advance to prevent  
discoloration.  
Baked Potato  
Depending on the size of the potato, cut in half or fourths. Boil, steam, or bake potato to  
complete doneness, then chill.  
French Fried Potato  
For best results, oven bake vs. deep fat frying is recommended. Steak fries are preferred  
over a crinkle cut or shoe string potato. Tator tots and potato wedges also rethermalize  
well. Bake according to recipe or package and blast chill.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 38]  
RICE  
Prepare according to standardized recipe, then blast chill. If rethermalized product is dry,  
liquid may be added.  
PASTA AND NOODLES  
Cook to al dente, rinse well with cold water, then chill. Chill in 2-1/2" pans with water  
with ice added. Drain partially before retherming. The best way to heat pasta is to run it  
under hot water or dunk it into boiling water for 30 seconds.  
FRIED FOODS  
It is difficult to achieve a crispy, chewy fried product with an advanced preparation food  
process. For best results, oven frying is recommended. If deep fat frying is still your  
choice, use crumb breading instead of batter. Fry in clean, hot oil, and drain well before  
chilling. Do not attempt to prepare further than one day ahead to avoid excess moisture.  
Use meat items with little or no bone to get a drier product. Fried foods should be  
produced conventionally when possible.  
CEREALS  
Cooked cereals such as oatmeal and grits continue to thicken when chilled and held under  
refrigerated storage. To obtain a desirable product, follow the following procedures.  
Cream of Wheat / Grits  
Prepare recipe according to the directions. At the end of cooking, add 50% more water  
and use a wire whip to stir in the water. Blast chill. The product should be the  
consistency of pudding. If it is not, add water. Use a wire whip and stir to a pudding  
consistency.  
Oatmeal  
Add 30% more liquid and follow recipe.  
EGGS  
Poached Egg  
If a poached egg must be served, cook to firm stage.  
Procedure:  
• Spray a 1/2 steam table pan (2" deep) with any type release agent (e.g. Pam™)  
• Fill with cold water, add 1/4 cup vinegar.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 39]  
• Add a 2" perforated insert to pan.  
• Break eggs (25-30) in separate bowl and slip onto the 1/2 pan insert.  
• Steam a maximum of 3 minutes (time should be tested at each facility as  
equipment performance will vary at each location).  
• Lift perforated insert out of pan and plunge into ice water to retard cooking. The  
whites will still have a wet, glossy look, but should hold shape.  
• Lift eggs out with slotted spoon and drain well before plating on trayline. Chill  
and store until trayline.  
• Eggs could be left to chill on perforated insert, drain well.  
Scrambled Egg  
A pasteurized egg product is recommended. Prepare to a soft, loose consistency.  
Remove from heat source, cover with plastic wrap, and immediately blast chill.  
Omelets  
Frozen convenience product must be fully tempered prior to assembly. For omelets  
prepared conventionally, follow existing standardized recipe. Omelet should be slightly  
undercooked, then blast chilled.  
Hard Cooked Egg  
Cook in usual manner and chill immediately. Store covered in walk-in cooler.  
PANCAKES/FRENCH TOAST/WAFFLES  
For pancakes/French toast prepared conventionally, shingle, stack, and blast chill for a  
short period of time (approximately 15 minutes). French toast made with Texas toast  
blast chills and retherms with the best quality.  
BREAKFAST MEAT  
Sausage  
Sausage patties are preferred over links for best heating. Cook sausage to 165° F.  
(74° C.), then drain well. Blast chill.  
Bacon  
Cook to point of service. Presentation is best if bacon is cooked to the crisp stage,  
drained, and patted dry with paper towels to remove excess fat. Blast chill.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[Page 40]  
BREAKFAST BURRITOS/CREPES  
Burrito and crepe filling is prepared conventionally and chilled. When filling is chilled,  
then fill crepes and burritos. Blast chill filled products.  
BREAKFAST SANDWICHES  
Prepare sandwich filling separately and chill. Assemble sandwiches, wrap, and blast chill  
for additional 15-20 minutes.  
HASH BROWNS/OVEN FRIES  
For both convenience and freshness, prepare to the point of complete doneness, then blast  
chill. Product should not be too dry.  
*Please note: The internal temperatures may continue to increase in the  
beginning of the blast chill cycle.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Continental Electric Food Processor CE22361 User Manual
Craftsman Drill 572610520 User Manual
Creek Audio Car Amplifier OBH 15 User Manual
Crown Audio Stereo Amplifier SST MX User Manual
Cypress Computer Hardware CY7C1019BN User Manual
Desa Water Heater FA 2B User Manual
Electro Voice Microphone 664A User Manual
Extron electronic Network Card IPL T IRL User Manual
Fellowes Printer Accessories Quasar e 500 User Manual
Generac Power Systems Portable Generator 00916 1 User Manual