FL 2242
Feb. 2000
BLAST CHILLERS
MODEL NUMBERS
CCBC-4-35
CCBC-12-75 CCBC12-UA-100
INSTALLATION, OPERATION & SERVICE
MANUAL
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
[ Page 1 ]
BLAST CHILLER INTRODUCTION
THE BLAST CHILLER is the easiest and simplest way to chill foods safely without additional labor. All food
service operators prepare foods in advance or chill foods at the end of a workday. More often than not the foods
are chilled in standard refrigeration, often creating an unsafe time and temperature environment. In using a
BLAST CHILLER food products are produced in the same manner and with the same equipment which is
used for conventional food preparation and chilled in a BLAST CHILLER. The BLAST CHILLER
resembles a reach in refrigerator. The BLAST CHILLER is a unit that moves cool air at a high circulation
over the top and bottom of each pan thus ensuring a rapid even chilling time. Almost all foods are chilled
within 2 hours out of the danger zone 140°F to 41°F. The time necessary to bring the internal food temperature
to 41°F. (5°C) is affected by the food density, moisture content and the food’s ability to retain heat. Blast
chilled food has a shelf life of five days, including day of production and service. Blast chilling works well
with a wide range of menu items. Nearly any food product that can be portioned into a standard 2-1/2” hotel
pan can be successfully blast chilled. These systems are used for services from 50 to 10,000 meals per day.
STEPS IN THE BLAST CHILL PROCESS
1.
2.
3.
4.
5.
Prepare all food products to the point of consumption. Within 30 minutes, portion into 2-1/2 inch deep
half-full pan or sheet pan at a depth of no more than 2 inches and weight of no more than 8 lbs.
Place pans of cooked product in the BLAST CHILLER and strategically place probe in the center of
the pan where the internal temperature is brought down to approximately 41°F (5°C) within 90 minutes.
At the completion of the “chill cycle” the pans of food product are removed and covered with either a
film wrap or stainless steel lid and labeled.
The product is stored in a refrigerator and maintained at a temperature between 33°F (1°C) and 38°F
(3°C).
The food product is rethermed just prior to the required meal service in bulk or individual portion.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description ]
[ Page 2 ]
Chill Processing Under-Counter and Reach-In Refrigerator/Storage Cabinet
CCBC-4-35
The CCBC-4-35 is ideal for food service operations, which require a small volume blast chiller. This
model is capable of chilling 35 lbs. of food product to 38°F in approximately 90 minutes. Daily capacity
is over 140 lbs. Of processed product.
The comprehensive control panel features built in-alarms and can control the chilling process with the
food core temperature probe or the digital timer.
At the end of the blast chill cycle the cabinet automatically reverts to a 38°F storage refrigerator.
CCBC-12-75 & CCBC-12-UA – 100
The CCBC-12-75 and CCBC-12-UA-100 are ideal for small to medium size food service operations,
which require a blast chilling capability. The CCBC-12-75 is capable of chilling 75 lbs. of food product
to 38°F in approximately 90 minutes. The daily capacity is over 300 lbs. of processed product. The
CCBC-12-UA-100 is capable of chilling 100 lbs. of food product to 38°F in approximately 90 minutes.
Daily capacity is over 400 lbs. of processed product
The comprehensive control panels feature built-in alarms and can control the chilling process with three
food core temperature probes or the digital timer.
At the end of the chill cycle the cabinet automatically reverts to a 38°F storage refrigerator.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description ]
[ Page 3 ]
CCBC-4-35 Chill Temp Blast Chiller
Standard Features:
ꢀ Stainless Steel Exterior and Interior
ꢀ Two Operational Features:
-
-
Blast Chill Processing Refrigerator
38°F Storage Refrigerator
ꢀ Operational Indicator Panel with Microprocessor:
-
-
-
-
-
-
Blast Chill Cycle Controlled Automatically by Either a Food Probe or Digital Timer
Four (4) Preset Chilling Times: 30, 60, 90, and 240 minutes
Cabinet Temperature Digital Display
Food Temperature Digital Display
Defrost Mode Indicator
On/Off, Blast Chill Cycle and Cancel Buttons
ꢀ Power Failure Alarm
ꢀ Stainless Steel Top, Front, Sides, Door and Interior
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description ]
[ Page 4 ]
ꢀ Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door
Gaskets
ꢀ Four (4) Pairs of Adjustable Panslides for 12" x 20" x 2 1/2" Pans
ꢀ Heavy Duty Casters
ꢀ Hot Gas Condensate Vaporization
ꢀ Large Surface Area Evaporator and High Velocity Fan
ꢀ CFC Free R-134A Refrigerant
SPECIFICATIONS
Capacity (lbs/90 mins)
Width
Depth
Open Door Depth
Height
ELECTRICAL DATA
Voltage
Amperage
Feed Wires & Ground
*10 Ft. Cord Installed
*Requires dedicated 15Amp. Service
35 lbs.
28"
32"
58 3/4"
34.5"
208/230V - 60/1
7
2
NEMA 6-15P
Clear Door Width
Clear Door Height
Number Of Tray Slides
REFRIGERATION DATA
R134a refrigerant
Compressor HP
BTU/HR
21 1/4"
15"
4 Sets (2ea)
WEIGHT
Crated
Uncrated
CRATED DIMENSIONS
Width
Depth
275 lbs
265 lbs
3/4 HP
3,706
31"
34"
39"
100°F Ambient
Evaporating@+5°F
Height
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description ]
[ Page 5 ]
CCBC-12-75 Reach-In Blast Chill
Standard Features:
ꢀ Stainless Steel Exterior and Interior
ꢀ Two Operational Features:
-
-
Blast Chill Processing Refrigerator
38°F Storage Refrigerator
ꢀ Operational Indicator Panel with Microprocessor:
-
Blast Chill Cycle Controlled Automatically by Either Food Probes or Digital
Timer
-
-
Four (4) Preset Chilling Times: 30, 60, 90, or 240 Mins.
Cabinet Temperature Digital Display
- Defrost Mode Indicator
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description ]
[ Page 6 ]
-
-
Power Failure Alarm
Three (3) Food Probes with Digital Temperature indicator
ꢀ Seven (7) Day Temperature Recorder with Printout Demand
ꢀ Stainless Steel Front, Sides, Door and Interior
ꢀ Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door Gaskets
ꢀ Twelve (12) Pairs of Adjustable Panslides on 3 1/2" Centers for 18" x 26" Sheet Pans
ꢀ Six (6) Wire Racks.
ꢀ Heavy Duty Swivel Casters with Locking Brakes on the Front
ꢀ Condensate Disposed of Automatically
ꢀ Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Service
Compartment
ꢀ Automatic Defrost
ꢀ CFC Free R-134A Refrigerant
SPECIFICATIONS
Capacity
Width
Depth
Open Door Depth
Height
Clear Door Width
Clear Door Height
Number Of Tray Slides
Number of Wire Racks
REFRIGERATION DATA
Compressor HP
BTU/HR
ELECTRICAL DATA
Voltage
Amperage
Feed Wires & Ground
*10 Ft. Cord Installed
*Requires separate 20Amp. Service
WEIGHT
Crated
Uncrated
75 lbs.
35 1/2"
32"
208/230V 60/1
15
2
58 1/4"
77 1/2"
18 1/4"
48 1/2"
12 Sets (2ea)
6
NEMA 6-20P
598 lbs
548 lbs
CRATED DIMENSIONS
1.5 HP
7,188
Width
Depth
Height
37 1/2"
38"
100°F Ambient
Evaporating @ +5°F
79"
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description ]
________[ Page 7 ]
The CBBC-12-UA-100 Reach-In Blast Chiller
Standard Features
Stainless Steel Exterior and Interior
ꢀ Two Operational Features:
-
-
Blast Chill Processing Refrigerator
38°F Storage Refrigerator
ꢀ Operational Indicator Panel with Microprocessor:
Full Microprocessor Controlled by a Digital Timer
-
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 1-Description_]
___
____[ Page 8 ]
-
-
-
-
On/Off Switch with Blast Cycle and Cancel Button
Digital Temperature Display and Defrost Indicator
Power Failure Alarm
Food Probe with Digital Temperature Indicator
ꢀ Galvanized Stee1 Top Stainless Steel Top, Front, Sides, Door and Liner
ꢀ Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic; Gaskets
ꢀ Twelve (12) Adjustable Universal Angles
ꢀ Heavy Duty Swivel Casters with Locking Brakes on the Front
ꢀ Automatic Defrost
ꢀ Condensation Disposed of Automatically
ꢀ Large Surface Area Evaporator and High Velocity Fan Contained in a Separate Compartment
ꢀ CFC Free R-404A Refrigerant
SPECIFICATIONS
Capacity
Width
ELECTRICAL DATA
Voltage
Amperage
100 lbs.
47"
39 3/8"
208/230 - 60/3
15.5
2
Depth
Feed Wires & Ground
Height
84"
Number Of Tray Slides
12 Sets (2ea)
WEIGHT
Crated
Uncrated
659 lbs
648 lbs
REFRIGERATION DATA
R404A refrigerant
Compressor HP
BTU/HR
CRATED DIMENSIONS
2 HP
10,400
Evaporating@+5°F
Width
Depth
Height
47"
39.375"
84"
100°F Ambient
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 9]
Control Panel For
CCBC-4-35
1. Select Chill Mode
2. Select Hard or Soft Blast
3. Select Timer for probe or time of process
4. When satisfied with selections, press Check to Start Cycle
Probe Temperature Displayed
5. Press if you want to erase and start
programming over
Cabinet Temperature or "DEF" when in Defrost cycle
Control Panel For
CCBC-12-75 & CCBC-12-UA-100
1. Select Chill Mode
2. Select Hard or Soft Blast
3. Select Timer for probe or time of process
4. When satisfied with selections, press Check to Start Cycle
Probe Temperature Displayed
Cabinet Temperature or "DEF" when in Defrost cycle
5. Press if you want to erase and start
programming over
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 2-Installation ]
UNPACKING INSTRUCTIONS
[ Page 10 ]
IMPORTANT:
It is highly recommended that your refrigerator or freezer be installed by an authorized
CresCor Service Agency (List enclosed)
A. Receiving Shipment
Upon arrival, examine the exterior of the shipment packaging for any signs of rough
handling.
If the cabinet is damaged, it should be noted on the delivery slip or bill of lading and signed
to that effect. A claim must be filed immediately against the carrier indicating the extent
and estimated cost of damage incurred.
All units are performance tested and thoroughly inspected prior to shipment. Upon leaving the
factory all units are in perfect condition and the carrier signs to this effect.
B. Uncrating Procedure
WARNING:
DO NOT, Under any Circumstances, Lay Your New Equipment Down on Either The Back,
Front, or Sides!!!
1. Check for any instructions printed on shipping carton.
2. Remove protective cardboard corners, sides and top.
3. Next remove the shipping skid.
4. If any concealed damage is discovered at this time, notify the carrier in writing, and
retain all carton and packing materials until an inspection has been made or waived
by the carrier. Taking a photo of the damage is recommended.
CAUTION:
Exercise extreme caution when removing the wooden skid.
5. Please Note the Model and Serial Number located on the inside right hand wall of the unit.
Please take the time to write these numbers down and keep in a safe place. A space has been
supplied for this purpose on the last page of this manual. This will assure you quality service
and support in the future. Also take the time to register your equipment to activate the
warranty.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 2-Installation ]
[ Page 11 ]
C. Removing Plastic Film
Stainless steel surfaces are protected with plastic film when shipped. The film is easily removed
by grasping an edge corner of the film and pulling it off.
D. Locating Your new Blast Chill Unit
The cabinet should not be placed in the immediate vicinity of ranges, ovens and other heat
radiating equipment. This will help to increase efficiency as well as lower operating costs. Self-
contained refrigeration is standard on reach-in chillers. Adequate air ventilation is mandatory
for the condensing unit in order to operate efficiently and to prevent excessive and damaging
operating temperatures. The Blast Chiller should be in an ambient room temperature of 85° or
less.
E. Leveling
The cabinet must be standing level on all four casters for the self-closing doors to operate
properly and for proper drainage of condensation from the evaporator. Casters are non-
adjustable, therefore the floor must be level.
F. Cleaning (refer to section 4)
G. Electrical Supply
All models (except the CCBC12-UA-100) are furnished with an electrical power cord & NEMA
plug, merely requiring that the appropriate NEMA receptacle is available at the installation
location. Model CCBC12-UA-100 requires a qualified electrician to furnish and install wiring
for the power supply. This must be connected to the identified terminals provided inside the
control panel. Refer to the appropriate wiring diagram furnished with the cabinet for guidance.
Electrical power of the current voltage, phase and ampacity must be supplied to the Blast Chiller.
The Chiller must have its own separate electrical circuit breaker with no other equipment or
appliance connected to that breaker. (Dedicated Circuit) See the cabinet data plate located on the
interior wall for the electrical requirements.
CHECK LIST (WITH POWER TURNED OFF)
***** EXAMINE THE FOLLOWING BEFORE START-UP! *****
CAUTION: Make sure the power to chiller is turned off prior to making
these checks to avoid the possibility of unexpected injury !!!
1.
Check that above installation recommendations have been adhered to. Pay particular
attention to installation location for any potential excessive heat sources (oven, range,
etc.) or inadequate air ventilation conditions which can cause compressor overheating
problems and/or failure. If any such condition exists notify the owner to have the installer
correct before continuing.
2.
Check refrigeration tubing for damage and that they are not touching or rubbing against
anything.
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 2-Installation ]
[ Page 12 ]
3.
Make sure cabinet is sitting level with all four (4) casters (or legs) in contact with the
floor.
4.
5.
Also make sure the door stays open when opened past 90 degrees.
Inspect magnetic door gasket to be sure it is making contact on all four (4) sides. Also
make sure it is not cut, torn, twisted or otherwise deformed.
6.
7.
Check installation of shelves or pan slides .
Check electrical power source for correct voltage, phase and ampacity. Refer to cabinet
data plate for requirements.
8.
9.
Remove electrical control box cover and check all wiring connections for a secure hold.
On rare occasions, rough shipping and handling conditions can result in loosening of
connections resulting in electrical problems.
Make sure all miniature circuit breakers are turned on.
10.
11.
Check all fan blades. They should turn freely without touching anything as they spin.
Check electrical power supply cord and plug for any damage and be sure it is not routed
in a way that would permit anyone to trip over it.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 3-Operation ]
[ Page 13]
GENERAL OPERATION OF BLAST CHILLER
All CRESCOR BLAST CHILLERS have 3 basic modes:
1.
Normal refrigeration storage 1°C/34°F to 3°C/38°F
2.
3.
Blast chill hard –10°C/14°F
Blast chill soft 1°C/34°
Normal Cycle 1°/34°F to 3°C/38°F
This is the storage temperature at which the food can be held.
Blast Chill Cycle (hard or soft)
During the blast chill hard cycle the air temperature inside the cabinet should go down to
approximately -10°C/14°F. This is for the timed or probe chilling cycle. Most applications will
use the hard cycle mode. During soft chill the air temperature stays above 0°C/32°F.
START UP INFORMATION
After you have completed all eleven (11) steps of the checklist, you are now ready to perform the
following steps:
1. Sanitize the inside of the cabinet and probes.
2. Turn on BLAST CHILLER left standby button-Display panel will indicate cabinet
temperature.
3. There may be an indicator “A7”. This indicates that there has been a power failure.
4. Press the red “x” cancel button to cancel alarm.
5. Allow the cabinet to chill in standard refrigerator mode for at least 30 minutes.
6. Run BLAST CHILLER (See HOW TO OPERATE below) without food product to
ensure all equipment is performing correctly. Use warm pans of water and place
probe tips in water to make sure the system is operating.
Do not submerge probes!
HOW TO OPERATE
The following instructions apply to all modes of CRESCOR BLAST CHILLERS
1. Turn on the chiller at least one half hour before use.
2. Check that the chiller is operating at storage temperature. Cabinet temp should be
40°F or lower.
3. Load the products to be chilled (see Loading Section page 4)
4. By pressing button ‘1’, select the ‘Chill’ mode
5. By pressing button ‘2’, select the desired blast function: "Hard Blast" or "Soft Blast".
( Use Hard Blast unless otherwise advised.)
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 3-Operation ]
[ Page 14 ]
6) By pressing button ‘3’, select the Timer for the desired duration or probed blast. Default to
probe blast unless it is known how long a product will chill.
7) If a variety of products are used make sure one probe is strategically placed near the top
shelf, 1 in the center and 1 at a lower shelf. If a variety of products are used make sure one
probe is in the largest item to be chilled. Place the CCBC-4-35 probe in the most difficult
to chill item located on shelf 2 or 3.
8) When you are happy with your selected program press the "D" to start the blast cycle.
9) If you are not happy with your selection press the "x" button to cancel your 1/2/3. If
cancelled repeat the above steps.
10) The blast chilling will begin.
TIP: You may open the door during blast chilling. This will not interrupt the cycle. If you add
additional food product make sure to use an Unused Clean probe in the product.
On completion of the blast chill cycle, when the product has reached 37°F, a buzzer will sound,
and “DEF” will be displayed in the “CABINET TEMP” window of the control panel. “DEF”
indicates the unit is defrosting. The blast chiller converts to a standard refrigerator.
During the defrost operation the temperature in the chiller will not exceed +3°C/38°F and it is
therefore safe to leave products in the chiller during the defrost cycle.
NOTE: Product can be set for blast chilling at the end of the labor shift. The products will store
safely in refrigeration hold mode until the next shift up to 24 hours.
BLAST CHILL CYCLE/MODES
All BLAST CHILLERS allow the operator to use any of the 4 pre-programmed timed cycle and
a probe control blast chilling cycle with the option of soft or hard blast.
PROBE CONTROLLED
The probe blast chill cycle functions with the internal probe(s) supplied. The probe monitors the
core temperature of the food and will not permit the blast cycle to stop until the default
temperature of 3°C/38°F is reached. The last product to reach 3°C 38°F will discontinue the
blast chill cycle.
When controlling the cycle with the food probe, make certain that the probe or probes are located
in the center of the product before the blast cycle is started. On BLAST CHILLERS equipped
with three food probes the cycle will not finish until all three probes have reached the correct
temperature.
CAUTION:
Easier to chill items may actually freeze prior to the end of the blast chill cycle of the harder to
chill item.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 3-Operation ]
[ Page 15]
To activate a blast chill cycle you must:
1.
2.
Choose the required store mode with button 1
Choose the require blast type with button 2
(select hard blast unless all items chilling are delicate)
Choose the blast duration or probe with button 3
3.
(select probe unless you know how long it takes the product to chill)
As each selection is made the indicator LED will illuminate to show what is chosen.
Press the “D”to accept, or “x” to cancel.
At the end of the blast chill cycle there will be an audible alarm, which will cancel automatically
after 15 minutes. (It may also be cancelled with the “x” button.)
After the blast chill cycle the cabinet will revert to a standard refrigeration mode appropriate to
store the foods until ready to use or transfer.
LOADING OF PRODUCT
1. All food products should be placed in either a 2-1/2” hotel pan or a sheet pan.
2. With the exception of roasted meats, all products should not be more than 2” in depth.
1-1/2” is recommended for very dense items such a lasagna and beef stew.
3. There should not be more than 7 lbs. of product per shelf.
4. Roast meats should be cut in ½ or 1/3 to allow for more effective chilling.
5. All Products should be blast chilled uncovered unless a “skin” may be formed (in
cream soups and sauces).*
6. Creamed soups and sauces should be covered with plastic wrap. The plastic wrap
should be touching the product to allow quick chilling. *
7. Probe(s) should be placed in the center of the pan or roast meat.
DEFAULT MODE
To save time for repeated identical blast operations, the blast selections are remembered, so
when 1-2-3 are pressed again, the selections automatically adopt the previous settings on the first
push. So to repeat a blast chill mode, just push 1 2 3 “D”.
DEFROST
At the end of each cycle, the defrost cycle will automatically clear any ice from the evaporator.
During operation in storage mode a defrost will be performed automatically at the factory pre-set
interval of 6 hours.
*see general rules of thumb pg. 30 for more information.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 3-Operation ]
[ Page 16]
If a blast cycle is cancelled and the defrost thermostat is measuring 1°C/32°F or less, the BLAST
CHILLER automatically goes into a defrost cycle.
When the BLAST CHILLER is in the defrost mode the “Cabinet Temp” window of the control
panel will display “DEF” During the defrost cycle some fans will stop running. This is normal.
When the defrost cycle is finished the compressor will run for approximately 90 seconds before
the fans operate.
Following every defrost period there is a 3 minute period during which a blast cycle cannot be
selected. This short interval is to allow for the water created by the defrost mode to dissipate.
The cabinet is now ready to start another blast cycle if desired.
During the defrost operation it is safe to leave products inside the blast chiller.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 3-Operation ]
[ Page 17]
PRINTER
If equipped, the printer is activated after each blast cycle. The printer provides hard copy
historical data of cabinet performance or warning tickets to archive or act upon.
The following formats are available:
Midnight Ticket
At midnight, a ticket is automatically printed for archiving in the morning. The midnight ticket
provides the following information:
-
-
-
Time and date of printout and cabinet number
Cabinet temperature at time of printout
A graph of cabinet temperature over the preceding 24 hours
Demand Ticket
A ticket may be requested from the control panel by holding the printer 'On/Off' button for five
(5) seconds. This ticket provides the same information as the midnight ticket except that up to
seven (7) days of historical data are printed.
Alarm or Warning Ticket
A ticket is automatically printed if any condition is detected by the microcontroller, which may
need attention. The print function may be terminated by pressing the printer 'On/Off' button.
Main Power Failure Ticket
If the main power fails for more than five (5) seconds a ticket is automatically printed which
gives the time of power failure and the time at which power is stored.
Sensor Failure Ticket
If the controller detects that one of its sensors has failed, then a warning ticket will be printed.
Power Failure
A power cut does not cause the loss of any accumulated historical data and no re-programming is
necessary. The controller's battery is continually charged and provides emergency back up under
normal power failure conditions.
Installing New Paper and/or Ribbon
Paper:
1. Lift Up and pull Out the printer cover.
2. Remove old cardboard roll, insert new paper roll in position so paper is fed unrolling from
the bottom backside.
3. Fold paper end into a V shape and thread it through the slot over the ribbon cartridge.
4. Press "FEED" button on panel....paper should feed through slot, If not, redo step 4 and try
again until paper feeds through. Check for proper operation.
Ribbon:
To Remove:
Hold ribbon cartridge between thumb and pointer finger, pull gently but firmly out (towards you)
To replace:
Snap new cartridge in place and re-feed paper. Check for proper operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 4- Maintenance ]
[ Page 18 ]
CAUTION !
HINTS:
1. Turn Off Blast Chiller
1. Use the mildest cleaning product that will
do the job
2. Always rub in the direction of polish lines to
Avoid scratching the surface.
2. Allow Cabinet to warm slightly.
3. Do not hose Blast Chiller.
ꢁWipe up spills as soon as possible.
ꢁClean regularly to avoid heavy dirt buildup.
3. Use only a soft cloth, sponge, fibrous brushes,
Plastic pads for cleaning and scouring.
4. Rinse thoroughly with fresh water after every
Cleaning operation.
5. Always wipe dry to avoid watermarks.
SOIL
CLEANER
Soap, ammonia or
METHOD
Routine Cleaning
1. Sponge on with cloth.
2. Rinse.
detergent* and water.
Stubborn spots
and stains
Mild abrasive made for
stainless steel.
1. Apply with damp sponge or cloth.
2. Rub lightly.
Probe
Antibacterial soap,
ammonia or detergent*
and water.
1. Remove excess food from probe.
2. Clean and sanitize.
Hard Water Spots
and Scale
Vinegar.
1. Swab or wipe with cloth.
2. Rinse and dry.
* Mild detergents include soaps and non-abrasive cleaners.
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 5- Troubleshooting ]
[ Page 19 ]
SERVICE & TROUBLESHOOTING
ꢀSetting or Resetting Time and Date
SET UP PROCEDURE
SWITCH
FUNCTION IN SPECIAL SWITCH MODE
I/O
1
ON/OFF SWITCH
When held in, displays the code for current parameter
2
Step back to previous parameter, and while held in displays the parameter
code. When released, displays the value of the parameter.
Advance to the next parameter. (same as above)
3
Increase the value of the current parameter.
ꢂ
X
Decrease the value of the current parameter
To set the parameters complete the following steps:
1. This can only be entered from the panel OFF mode.
2. Press and HOLD IN any key EXCEPT the ON/OFF key for three seconds.
3. While Holding key, press and release the ON/OFF key.
You will now be in the programming mode.
CODE
bss
bhs
bfs
sss
shs
sfs
bsd
bhd
bfd
PARAMETER
SET AT:
33
Blast Soft Stat
Blast Hard Stat
Blast Freeze Stat
Store Soft Stat
12
-16
33
33
-8
35
35
35
35
Store Hard Stat
Store Freeze Stat
Blast Soft Differential
Blast Hard Differential
Blast Freeze Differtial
Store Soft Differential
Store Freeze Differential
ssd
sfd
35
bd1
bd2
bd3
bd4
cab
ala
Blast Duration 1 (normally 30 min.)
Blast Duration 2 (normally 60 min.)
Blast Duration 3 (normally 90 min.)
Blast Duration 4 (normally 240 min)
Cabinet Number
Alarm Duration
Defrost Duration for Cabinet
Defrost Interval for Cabinet
30
60
90
240
1
900 (15 min)
Hex. Switch
Hex. Switch
ddc
dic
ddp
dip
det
N/A defrost Duration for PoD minutes, Set Manually
N/A defrost Interval Hours, Set Manually
Defrost Target Temperature
39
yr
nth
day
hr
Calander Year Setting
Calander Month Setting
Calander Day Setting
Calander Hour Setting
Calander Minute Setting
Set Accordingly
Set Accordingly
Set Accordingly
Set Accordingly
Set Accordingly
ute
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 5- Troubleshooting ]
ALARM CODES
[ Page 19a ]
7-Segment Display
The left hand window shows the cabinet wall temperature.
The right hand displays show the probe temperatures during a blast cycle, and are normally blank
during store. If a probe fails it will indicate pf (probe failure) during a blast.
Cab temp window also acts as a count up timer in probe blast.
If there is an alarm condition, the top probe display will show an alarm number a0 to a7
during store (see table below), but will still show the probe temperature during blast.
7-Seg Display
Alarm Condition
a0
a1
a2
AIR ON SENSOR FAILURE
WALL SENSOR FAILURE
FIN SENSOR FAILURE
a3
a4
FOOD PROBE 1 FAILURE *
FOOD PROBE 2 FAILURE
a5
a6
a7
FOOD PROBE 3 FAILURE
SPARE
POWER CUT DETECTED
* (Top Display On Front Panel Used For 3 Probe Systems)
Note: for each probe only one audible alarm and alarm printout is allowed to be issued
each day. This is to prevent excessive paper use and noise nuisance in the event of an
intermittent probe failure. However, repeated probe failures are displayed on the probe
display window, (top window in the case of 3 probe panels)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 5- Troubleshooting ]
ꢀ Cabinet has no power to controller-display not lit:
[ Page 20 ]
1. Make sure the power is connected to the cabinet that the cord is plugged in on the
models with power cord and plug.
2. Check main circuit breaker at power supply panel; make sure it is on.
3. Model CCBC-12-UA-100 only, has an "isolator" (disconnect) switch on the control box,
make sure it is on.
4. Check circuit breakers inside cabinet control box; make sure all are on.
Check control power supply circuit safety klixon (some models). If tripped due to
having exceeded 158°F, some models must be manually reset by pushing the red reset
button (make sure power is turned off before doing this to avoid any unexpected
injury!). Other models will reset automatically.
5. Check fuse on PC board.
6. Check for loose wiring.
7. Check plug in connectors for interconnecting cords and cables from main to front
"Touch Pad" operators panel.
8. Defective communications ribbon cable.
9. Defective main or front PCB.
ꢀ Cabinet has power, display shows "OFF". Turn cabinet "on" by pressing "OFF/ON" button.
1. Compressor not running:
(a) Manually close compressor contactor (if utilized) temporarily to see if
compressor runs.
(b) If compressor runs, check compressor control circuit for problem.
(1) Is the Dual Pressure Control open?
-
-
-
Check for correct settings
Low or no refrigerant charge
Liquid Line Solenoid Valve (if used) not opening?
(c) If the compressor doesn't run, check if you have power to compressor
terminals.
(1) If no power to terminals, trace back until power is found. Correct
problem.
-
If single phase, check start relay and capacitor(s).
(2) If power is present at compressor terminals, check for stripped
compressor overload and/or "open" or grounded compressor-motor
windings.
2. Compressor does run:
(a) Compressor short cycles.
(1) Check DPC settings. Cut-in and/or differential may need to be
adjusted.
(2) Check refrigerant charge may be low.
-
If low, or no charge, check for leaks, repair and recharge as
necessary.
(3) Check if thermostatic expansion valve is feeding properly.
(4) Check Chiller Store Thermostat ("St 1") and Differential ("Dt 1")
settings.
(5) Check the "fin" and "air on" thermocouples at main PCB to make sure
they are not interchanged.
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 5- Troubleshooting ]
[ Page 21 ]
3. Compressor runs continuously.
(1) Check compressor for "pumping" efficiency.
(2) Door not closed tight or gasket leaking.
(3) If no DPC, or if DPC set too low to open, check refrigerant charge
and/or thermostatic expansion valve for adequate feeding.
ꢀ Cabinet has power, display shows "Sto", but load of hot food takes extremely long to chill:
1. "Sto" is the storage mode and cannot chill food properly. You must first choose a
"PROGRAM" and then press "BLAST" in order to make the machine do a blast chill
cycle to quickly chill hot food.
ꢀ In "BLAST" mode, unit runs, but doesn't chill the food fast enough.
1. Food too "thick" - limit 2 inches maximum for optimum performance.
2. Food too hot when placed inside - temperatures above 160°F increase pull-down time
proportionally.
3. Too much food - exceeding rated pounds of capacity increases pull-down time
proportionally.
4. Food covered (air trapped between food and cover is and insulator).
5. Container too large (distance from outside of container to center of food within is too
great, shouldn’t exceed 2 inches for optimum performance).
6. Container material is plastic (an insulator) instead of metal (a conductor).
7. If cabinet was off did not pre-chill before loading with hot food.
8. If using timed program, incorrect amount of time being selected.
9. Mechanical problem:
(a) Inadequate refrigerant charge.
(b) Thermostatic Expansion Valve defective.
(c) Evaporator fan(s) not working.
(d) Evaporator coil iced (see below for possible causes).
(e) Inadequate refrigeration (BTUH) capacity:
-
-
-
-
-
Condensing unit ambient, or too high
Condenser fan not working (if air cooled)
Condenser dirty
Compressor inefficient (or defective)
Refrigerant line restriction
Evaporator coil iced:
1. Check how cabinet is being operated:
(a) Placing load of hot food inside and merely closing door is improper use.
Doing this keeps unit in the storage ("Sto") mode resulting in extremely long
pull-down times and does not initiate an automatic defrost. As a result the
evaporator coil becomes heavily iced.
(b) Must run a "BLAST" cycle for automatic defrosting to occur.
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
[Section 5-Troubleshooting ]
[ Page 22 ]
2. Door not shut tight
3. Gaskets leaking
4. Check defrost heater operator (if used):
(a) Defective heater
(b) Blown fuse (if used)
(c) Defective "klixon" if used
5. Check defrost settings:
(a) Check defrost thermostat ("St 5") setting
(b) Check defrost differential ("dt 5") setting
(c) Check Defrost Period Switch on main PCB inside control box
(d) Check Defrost Length Switch on main PCB control box.
6. Check that ambient temperature has not exceeded 100°F or 100% humidity.
ꢀ Display reads - 58° F
1. Thermocouple is "open" :
(a) If food probe, check the make sure it's plugged into probe receptacle properly
(b) Check for loosened thermocouple wire connection at all connections
(c) Check for broken or cut thermocouple wire
(d) Temperature display not believable - responds in reverse:
-
Polarity of thermocouple wire is reversed
ꢀ Evaporator won't run:
1. Breaker not on (if equipped)
2. Motor overload tripped (if equipped)
3. In post-defrost "Drip" period
4. "Fan door" switch is open (if equipped)
5. Blown fuse (if used)
6. Defective contactor (if equipped)
7. Motor defective
ꢀ Printer problems (if equipped) :
1. Printer doesn't run:
(a) "Link" (jumper) on main PCB not installed
(b) Damaged communications "ribbon" cable
(c) Defective printer
(d) Defective PCB
2. Printer "runs", but no paper comes out:
(a) Check if paper roll is loaded
(b) Check for jammed paper tape -
-
Before loading a new roll, make sure free end of tape is pulled
completely away from the roll. Remove any paper residue. (The
residue will undoubtedly result in a paper jam).
Carefully remove any paper residue from printer platen, otherwise
another jam could occur.
-
(c) Check for proper tape feed
3. Printer runs, but paper comes out with no printing:
(a) Check if printer has ribbon cartridge installed
(b) Check ribbon - condition may be out of ink, dried out, or torn
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 5-Troubleshooting ]
[ Page 23 ]
(c) Check make sure ribbon cartridge is properly installed - both sides snapped in
place
4. Printer is printing backwards and all characters reversed
(a) Paper tape is feeding incorrectly over top of printer ribbon. This can readily
occur when inserting a ribbon cartridge with paper tape still protruding from
the printer. The ribbon must be on top of the paper in order to print
correctly.
5. Paper rolls and ribbon cartridges are available from CresCor Authorized Parts
Distributors.
ꢀ Odors inside cabinet:
1. Spilled food inside - clean as required
2. If not being used for a long period of time, turn off, clean interior and keep door open
to ventilate. Alternatively after cleaning, place and odor absorbent such as baking
soda inside with the door kept closed. Remove before restarting.
ꢀ Alarm conditions:
1. Cabinet wall temperature above 38°F more than 60 minutes
2. Defrost termination on time instead of temperature
3. Compressor overheating (if temperature is greater than 217°F for 1 minute)
4. Compressor run (if the compressor runs continuously for more than 6 hours in either
blast mode or storage mode)
5. Faulty sensor (including food probe)
6. Loss of power for 5 seconds or more
7. Dead battery
ꢀ Food dried out
1. Uncovered containers
2. Left in storage too long
ꢀ Food frozen
1. Too long blast cycle
(a) Choose a shorter timed program
(b) Use the probe program
2. Uneven food portions-thinner foods can freeze by the time thicker portions reach
temperature
3. Monitor temperatures more frequently if uneven food loads and remove those when
reaching end temperature
4. Food probe defective
5. Stat 1 set too warm
ꢀ Food not cold enough
1. Timed cycle too short
2. Stat 1 set too warm
3. Food probe tip not in center of food
4. Defective probe
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Section 6 – Parts and Drawings ]______________________ __
[ Page 24 ]
Parts List and Breakdown Drawing of Blast
Chillers
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 25 ]
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 26 ]
PARTS LIST CCBC-4-35 BLAST CHILLER 208V 60HZ SINGLE PHASE
Drawing Number
Description
Part Number
1
1a
1b
1c
2
COMPRESSOR CAJ 4492Y R134A
CONDENSER 3X11X21
WCOMP 345
WCOND 250
DRIER 1/4 X 3/16 SWEAT T R134A
SIGHT GLASS 1/4" SWEAT
RECEIVER 2.2 L
WDRIER 110
WSIGHT 020
WRECEIVER 060
WVALVE 196
3
EXPANSION VALVE BODY TEN 2 R134A
1/4" SOLDER ADAPTOR
3
WVALVE 198
3
ORIFICE NO. 3
WVALVE 201
4
CONDENSOR FAN MOTOR 16 WATT
CONDENSOR FAN BLADE 10" 27° PITCH
CONDENSOR FAN PLATE
WMOTOR 270
4
WBLADE 070
5
WCFP/WBC35/99/1
WMOTOR 420
6
EVAPORATOR FAN 315MM AXIAL FAN (ZIEHL EBM)
EVAPORATOR WIRE FAN GUARD 50MM DEEP
EVAPORATOR FAN PLATE
RACKING
7
WGUARD 090
8
WEFP/WBC35/99/1
WLR/WBC35/99/1
WPROBE 100
9
10
10a
11
11a
12
13
14
15
16
17
18
19
20
21
22
23
23
23
24
25
26
27
28
29
30
31
32
33
FOOD PROBE
FLANGED SOCKET
WPROBE SOCKET 010
WUCT/WBC35/99/1
WUCB/WBC35/99/1
WGASKET 905
WHINGE 020
UNIT COVER (TOP)
UNIT COVER (BOTTOM)
GASKET: 680MM X 430MM
HINGE PLATE: R7 OPAL-TOP
HINGE: SPRING LOADED
WHINGE 290
STANDARD DOOR
WWBC35 STD DOOR/99/1
WEVAP 485
EVAPORATOR 4X13X17
DRIP TRAY
WDT/WBC35/99/1
WHEATER 030
WDOOR NYLON NEW
WLADDERACK 020
WSCREW 140
DEFROST HEATER 3 BEND 300W
NEW DOOR NYLON
LADDERRACK MOUNTING BLOCK
SCREW: M6 X 12 POZI PAN ZINC T/T
WBC/SPEC B1 WITHOUT PT. NO 4253
AARDWARE FRONT PANEL
AARDWARE BACK BOARD NO PRINTER
1M RIBBON TO CONNECT TO FRONT & BACK
LEGS: S/S 4" SHORT STUD C/C PLATE
KLOCKNER MOELLER DIL 00M 190V 50HZ/220V 60HZ
6MM X 25MM ZINC POZI PAN TAP TIGHT SCREWS
S/S/ SLIDE 585MM (2 OFF PER SLIDE 276MM)
LATCH: UNIT COVER (CLIP)
STRIKE: UNIT COVER (CLIP)
8MM X 20MM ZINC SET SCREWS
REAR COVER
WLABEL 701
WAARDWARE 010
WAARDWARE 030
WLOGGER RIBBON 010
WLEG 050
WCONTACT 190
WSCREW 180
WS/SLIDE 06O
WLATCH 030
WSTRIKE 010
WSCREW 585
WRC/WBC35/99/1
WHGV/335X185/88/1
WPLUG 170
HOT GAS VAPORIZER
PLUG
34
35
CORD
WCABLE 520
WLADDERACK 010
LADDERRACK MOUNTING BLOCKS
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 27 ]
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 28 ]
PARTS LIST CCBC-12-75 BLAST CHILLER 208V 60HZ SINGLE PHASE
Drawing Number
Description
Part Number
1
1
COMPRESSOR FH4518Y 208/220V 60HZ
CONDENSER 4X17X17.5
EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL
FLAT GUARD
WCOMP 365
WCOND208
3
WFAN 115
3
WGUARD 080
3
1.5 UF CAPACITOR 230V 60HZ
EVAPORATOR 4X12X41
WCAPACITOR 050
WEVAP311
4
5
SIGHT GLASS 3/8" SWEAT
DRIER 3/8" SUITABLE FOR H134A
EXPANSION VALVE TEN 2 R134A
3/8" SOLDER ADAPTOR 068-2060
ORIFICE NO. 3
WSIGHT 010
6
WDRIER 080
7
WVALVE 196
7
WVALVE 197
7
WVALVE 231
8
DEFROST HEATER 2X500 WATT 1 BEND
VAPORIZER HEATER 115 WATT 3 BEND
HEATER WIRE 4.35M 240V (57 WATT)
KLIXON 14T31 30210 L13C 9651
FOOD PROBE
WHEATER 400
WHEATER 010
WHEATER WIRE 340
WSTAT 410
9
10
11
12
13
14
14
14
14a
15
16
17
18
19
19a
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
36
37
38
39
40
41
42
43
44
45
46
WPROBE 1OO
PROBE SOCKET
WPROBE SOCKET 010
WAARDWARE 020
WAARDWARE 010
WAARDWARE RIBBON 020
WLABEL 746
AARDWARE FRONT PANEL C/W PRINTER
AARDWARE BACK BOARD
1.5M RIBBON TO CONNECT TO FRONT & BACK
LABEL: 3 PROBE F°
HIGH / LOW PRESSURE STAT
NEW DOOR NYLON
WSWITCH 360
WDOOR NYLON NEW
WHINGE 290
HINGE: SPRING LOADED
SWITCH: THERMAL HEATED 331-528
CASTOR 6" W/BRAKE
WSWITCH 200
WCASTOR 040
WCASTOR 030
WHINGE 070
CASTOR 6" NO BRAKE
HINGE PLATE: R4 OPAL/T2U
LADDERACK BLOCKS
WLADDERACK 020
WUC/WBC75/99/1
WCP/WBC75/99/1
WWBC75 STD DOOR/99/1
WGASKET 900
WLR/WBC75/99/1
WDT/WBC75/99/1
WBP/WBC75/99/1
WEFP/WBC75/99/1
WEBP/WBC75/99/1
WCFP/WBC75/99/1
WBIGHEAD 010
WSCREW 200
UNIT COVER
CONTROL PANEL
DOOR
GASKET 1295MM X 565MM
LADDERACK (1SET)
DRIP TRAY
BAFFLE PLATE
EVAPORATOR FAN PLATE
EVAPORATOR BAFFLE PLATE
CONDENSER FAN PLATE
BIGHEAD M/4T38 6X26
SCREW M6X25 POZI COUNTERSUNK
SCREW M6X25 POZI PAN ZINC T/T
ELECTRIC VAPORIZER
WSCREW 180
WEV/800X235/88/l
WMOTOR 410
CONDENSOR FAN 120W MOTOR
3.0 UF CAPACITOR 230V 60HZ
CONTROL PANEL BOTTOM
HINGE: BLACK PLASTIC
KLOCKER MOELLER DIL OM 190V 50HZ/220V 60 HZ
RECEIVER 2.2 LT
WCAPACITOR 060
WCPB/WBC75/99/1
WHINGE 560
WCONTACT 160
WRECEIVER 060
WBIGHEAD 060
WPLUG 160
BIGHEAD 316-F2/ST38 M5X5
MAINS PLUG
MAINS LEAD
WCABLE 510
LINER BASE
WS/SBASE 180
WTS/WBC75/99/1
WCPRC/WBC75/99/1
TRAY SLIDE
CONTROL PANEL REAR COVER
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 29 ]
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 30 ]
PARTS LIST CCBC-12-UA-100 BLAST CHILLER 208V 60HZ 3 PHASE
Drawing Number
Description
Part Number
1
2
COMPRESSOR TFH 4524Z 208/230V 60HZ
CONDENSER 4X17X17.5
WCOMP 833
WCOND208
3
EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL
FLAT GUARD
WFAN 115
3
WGUARD 080
3
1.5 UF CAPACITOR 230V 60HZ
EVAPORATOR 5X45X16
WCAPACITOR 040
WEVAP348
4
5
SIGHT GLASS 3/8" SWEAT
DRIER 3/8"
WSIGHT 010
6
WDRIER 080
7
EXPANSION VALVE TES 2 R404A
3/8 SOLDER ADAPTOR 068-2060
ORIFICE NO. 3
WVALVE 191
7
WVALVE 197
7
WVALVE 231
8
DEFROST HEATER 2X500 WATT 1 BEND
VAPORIZER HEATER 115 WATT 3 BEND
HEATER WIRE 4.35M 240V (57 WATTS)
KLIXON 141T31 30210 L13C 9651
FOOD PROBE (3 EACH)
WHEATER 500
9
WHEATER 010
10
11
12
13
14
14
14
14
14a
15
16
17
18
19
19a
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
WHEATER WIRE 340
WSTAT 410
WPROBE 1OO
PROBE SOCKET
WPROBE SOCKET 010
WAARDWARE 070
WAARDWARE 040
WLOGGER CHIP 170
WAARDWARE RIBBON Sm
WLABEL 918
AARDWARE FRONT PANEL C/W PRINTER
AARDWARE BACK BOARD
LOGGER CHIP
1.M RIBBON TO CONNECT FRONT & BACK
NEW BLAST CHILL 3 PROBE C/W PRINTER
HIGH / LOW PRESSURE STAT
NEW DOOR NYLON
WSWITCH 360
WDOOR NYLON NEW
WHINGE 290
HINGE: SPRING LOADED
SWITCH: THERMAL HEATED
CASTOR 6" W/BRAKE
WSWITCH 200
WCASTOR 040
CASTOR 6" NO BRAKE
WCASTOR 030
HINGE PLATE: R4 OPAL/T2U
LADDERACK BLOCKS
WHINGE 070
WLADDERACK 020
WUC/WBC1I0/99/1
WCP/WBC1I0/99/1
WWBC110 STD DOOR/99/1
WGASKET 895
UNIT COVER
CONTROL PANEL
DOOR
GASKET: 1354MM X 627MM C/C
LADDERACK (1SET)
WLR/WBC110/99/1
WDT/WBC110/99/1
WBP/WBC110/99/1
WEFP/WBC110/99/1
WEBP/WBC110/99/1
WCFP/WBC110/99/1
WBIGHEAD 010
WSCREW 200
DRIP TRAY
BAFFLE PLATE
EVAPORATOR FAN PLATE
EVAPORATOR BAFFLE PLATE
CONDENSER FAN PLATE
BIGHEAD M/4T38 6X26
SCREW M6 X 25 POZI COUNTERSUNK
SCREW M6 X 25 POZI PAN ZINC T/T
ELECTRIC VAPORIZER
WSCREW 180
WEV/800X235/88/l
WMOTOR 410
CONDENSER FAN 120W MOTOR
CONTROL PANEL BOTTOM
HINGE: BLACK PLASTIC
WCPB/IWBC/110/99/1
WHINGE 560
KLOCKER MOELLER DIL OM 190V 50HZ/220V 60HZ
RECEIVER 3.3 LT
WCONTACT 160
WRECEIVER 070
WBIGHEAD 060
WCFC/WBC110/99/1
WSLID/WBC110/99/1
WCPRC/WBC110/99/1
WTHERM 230
BIGHEAD 316-F2/ST38 M5X5
CONDENSER FAN COWL (BEHIND FAN)
UIVERSAL ANGLES (24 PER CABINET)
CONTROL PANEL REAR COVER
THERMOCOUPLE TYPE T PTFE 2M
SHELF GARNET WHITE COATED (X12)
WSHELF 185
Download from Www.Somanuals.com. All Manuals Search And Download.
General Rules of Thumb
[ Page 31 ]
ꢃPre-Chill the cabinet for thirty (30) minutes before you do first load.
(to remove interior residual heat)
ꢃDoubling the food thickness triples the pull-down time.
ꢃDon't stack food or containers on top of or alongside of each other.
(this increases the "thickness)
ꢃCovering the food increases pull-down time by 10%-30%.
ꢃPull-down rate initially is about 2°F per minute and approaching final temperature is about 2
minutes per degree F.
ꢃ"A watched pot never boils"
ꢃFactors affecting blast chill pull-down times:
(A)Initial food temperatures
(The hotter the initial food temp., the longer the pull-down time)
(B) Final food temp. (the colder the final temp., the longer the pull-down time)
(C) Food "thickness"(the greater the distance from geometric "core" center of food to its
surface, the longer the pull-down time)
(D)Food density (the greater the density, the longer the pull-down time)
(E) Container surface area(the smaller the surface area, the longer the pull-down time)
(F) Container material (metals are conductors which will shorten the length of pull-down
time, while plastics are insulators which will increase pull-down time)
(G)Covering material (metal preferred, same reasons as above)
(H)Covering method (Covering which is in direct contact with the food will pull-down
quicker than covering that is stretched tight leaving a "dead air" space between cover
and food. Air acts as an insulator and will increase the pull-down time)
(I) Amount (weight) of food put in as compared to rated capacity (exceeding rated
capacity will lengthen the time of pull-down)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contact Information
[ Page 32 ]
Please Send Serial registration information to :
Fax: (800) 378 – 8333
E-mail to: parts&[email protected]
Or
Mail To:
CresCor
5925 Heisley Road
Mentor, OH 44060
Toll Free: 877-273-7267 Fax: 440-350-7267
See us online at: http://www.crescor.com
Questions?
Call and Speak To One Of Our
Friendly Service Counselors:
Ellery @ Ext. 319
Pat @ Ext. 214
Download from Www.Somanuals.com. All Manuals Search And Download.
[ Page 33 ]
Notes
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
Date Purchased
________________
Date of Installation ________________
Serial Number
Model Number
_________________________
_________________________
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 34]
MEATS*
Roasted Meats
Roasted meats should be prepared according to the recipe using roast guidelines for each
product.
Roast Beef (top round) - Follow recipe and roast guidelines. Recommended
doneness for rethermalization is about 140° F. (60° C.). Top round should be
quartered and placed in the blast chiller. If roast beef is used for cold sandwiches,
the end cooking temperature may be higher. If medium doneness is desired, roast
to 150° F. (65° C.). Do not overcook.
Pork Roast - Follow recipe and roast guidelines. Recommended doneness for
rethermalization is 165° to 170° F. (74° to 76° C.). Do not overcook or product
will be dry.
Lamb Roast - Follow recipe and roast guidelines. Recommended doneness for
rethermalization is 155° F. (68° C.). Do not overcook.
Proportioned Meats (hamburger patty, pork chop, Salisbury steak, etc.)
Cook according to recipe. If sauce or gravy is required, it should be prepared and chilled
separately from the portioned meat.
Steak (filet, strip, ribeye) - Broil steak to medium rare or preferred stage of
doneness. Blast chill immediately.
Salisbury Steak - Bake to 165° F. (74° C.) Drain well, remove all grease. Blast
chill. Add gravy after steak is chilled.
Pork Chops/Cutlets - Breaded, baked, or broiled chop is heated only to 165° F.
(74° C.) and blast chilled immediately. Add sauce or gravy after chilling.
Turkey/Chicken
Cook turkey or chicken whole or breasts according to directions to 170° F. (76° C.).
Blast chill immediately. Slice product to a 1/4" thickness, single layered. Pre-cooked
turkey products do not require roasting.
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 35]
Seafood
Fish - Prepare all fish fillets according to recipe for breaded, baked, broiled,
steamed, etc. Be careful not to overcook. Blast chill immediately.
Shrimp/Scallops/Shellfish - Prepare according to recipe and blast chill
immediately. Be careful not to overcook. If prepared with a sauce (creole, etc.),
cook the sauce separate and mix together prior to retherm.
Casseroles and Stews
Stew and casseroles are very successful in cook/chill and rethermalization. Most recipes
should require little change for cook/chill. Products should be moist but hold form when
plated. Prepare and blast chill in 2-1/2" full pans.
Lasagna - Brown off convenience lasagna to remove extra moisture and blast chill.
Prepared from scratch, follow the recipe; do not overcook. Blast chill.
Beef Stew/Stroganoff, etc. - Cook/steam meat until tender. Prepare as stated in
recipe. Blast chill.
Chicken/Turkey/Beef Pot Pie - Prepare the chicken/turkey/beef and vegetable
sauce separately from the crust, pastry, or biscuit. Top product after chilling or at
point of rethermalization.
Stir Frys – Sauté / steam until meat is done and vegetables are crisp.
Pasta Casserole (Mac & Cheese, Turkey Tetrazzini) - Prepare sauce separately
from pasta. Blast chill. Mix product together chilled and rethermed.
Sauces and Gravies
For conventionally prepared gravies and sauces, substitute a portion of the flour or
cornstarch with a modified starch. A substitute of 30 to 50% by weight is recommended.
In preparing these sauces and gravies with the modified starch, the product must reach
170° F. (76° C.) and be held at the temperature for a minimum of 5 minutes. If this is not
done, the gravy or sauce will thicken during the chilled storage. To reduce the risk of
rancidity during refrigerated storage, use broth bases rather than meat or poultry
drippings. Commercial gravy or sauce bases contain modified starches and can be
substituted for conventionally prepared products.
Sandwiches/Specialty Items
See CresCor Retherm Oven Time and Temperature chart on Page 60 in CresCor
cookbook.
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 36]
SOUPS
Conventional Soup
Prepare conventionally. For creamed soups, substitute a modified starch for a portion of
the thickening agent by 30 to 50%.
Canned Soup
No cooking is necessary for broth based soups. Cream soups should be diluted with milk
or water, mixed completely, and blast chilled.
Frozen Soup
Follow instructions on the soup container for preparing soup, blend thoroughly, and blast
chill.
VEGETABLES
Add seasonings to vegetables prior to panning. If margarine is added, a more even
distribution will occur with liquid margarine.
Frozen Vegetables
Frozen vegetables do not require cooking before rethermalization.
For bulk rethermalization, vegetables do not need to be cooked or blast chilled before
service and should be prepared as in conventional production.
Canned Vegetables
Canned vegetables do not require any cooking. All canned vegetables can easily be bulk
rethermed with little liquid remaining.
Fresh Vegetables
Many fresh vegetables can be used in cook/chill. The desired texture of the product will
determine the preparation procedure.
Zucchini/Yellow Squash Steam or stir fry to desired consistency then blast chill.
Broiled Tomato
Slice in half and sprinkle on topping. Broil to brown topping
and blast chill immediately. Tomato will continue baking during rethermalization.
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 37]
Broccoli/Cauliflower/Green Beans/Carrots
Prepare green beans and carrots in
bite size and broccoli and cauliflower in flowerets. Steam to desired doneness,
then blast chill.
Stuffed Vegetables (eggplant, zucchini) Prepare stuffing and blast chill. Steam
shell and blast chill or place in ice bath. Stuff vegetable shell and blast chill to
bring temperature down from time of assembly.
Grilled Vegetables
Grill according to recipe. Place in 2-1/2" pan and blast chill.
POTATOES
Occasionally, "graying" or slight darkening of the cut surfaces of some cooked potatoes
will occur during chilling. This is an oxidation reaction and varies with the variety of
potato, soil, and weather conditions. Varieties that most often exhibit darkening are:
Irish, Ontario, Norland, and Red Pontiac.
Potatoes are fully cooked before blast chilling. Canned potatoes, well drained, can be
used without further cooking.
Mashed Potato (flakes or powder)
Follow recipe according to the package. Product should be smooth, easy to scoop, and
hold its form loosely at the point of blast chilling. Product should stay at that consistency
after blast chilling. If the product becomes stiff or dry, add water and stir into product.
Mashed Potato (fresh)
Follow recipe. Potatoes should be very soft before mashing and adding liquid. Follow
same consistency rule as for flake or powder potatoes. Cover with plastic and blast chill.
Fresh mashed potatoes should not be made more than 48 hours in advance to prevent
discoloration.
Baked Potato
Depending on the size of the potato, cut in half or fourths. Boil, steam, or bake potato to
complete doneness, then chill.
French Fried Potato
For best results, oven bake vs. deep fat frying is recommended. Steak fries are preferred
over a crinkle cut or shoe string potato. Tator tots and potato wedges also rethermalize
well. Bake according to recipe or package and blast chill.
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 38]
RICE
Prepare according to standardized recipe, then blast chill. If rethermalized product is dry,
liquid may be added.
PASTA AND NOODLES
Cook to al dente, rinse well with cold water, then chill. Chill in 2-1/2" pans with water
with ice added. Drain partially before retherming. The best way to heat pasta is to run it
under hot water or dunk it into boiling water for 30 seconds.
FRIED FOODS
It is difficult to achieve a crispy, chewy fried product with an advanced preparation food
process. For best results, oven frying is recommended. If deep fat frying is still your
choice, use crumb breading instead of batter. Fry in clean, hot oil, and drain well before
chilling. Do not attempt to prepare further than one day ahead to avoid excess moisture.
Use meat items with little or no bone to get a drier product. Fried foods should be
produced conventionally when possible.
CEREALS
Cooked cereals such as oatmeal and grits continue to thicken when chilled and held under
refrigerated storage. To obtain a desirable product, follow the following procedures.
Cream of Wheat / Grits
Prepare recipe according to the directions. At the end of cooking, add 50% more water
and use a wire whip to stir in the water. Blast chill. The product should be the
consistency of pudding. If it is not, add water. Use a wire whip and stir to a pudding
consistency.
Oatmeal
Add 30% more liquid and follow recipe.
EGGS
Poached Egg
If a poached egg must be served, cook to firm stage.
Procedure:
• Spray a 1/2 steam table pan (2" deep) with any type release agent (e.g. Pam™)
• Fill with cold water, add 1/4 cup vinegar.
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 39]
• Add a 2" perforated insert to pan.
• Break eggs (25-30) in separate bowl and slip onto the 1/2 pan insert.
• Steam a maximum of 3 minutes (time should be tested at each facility as
equipment performance will vary at each location).
• Lift perforated insert out of pan and plunge into ice water to retard cooking. The
whites will still have a wet, glossy look, but should hold shape.
• Lift eggs out with slotted spoon and drain well before plating on trayline. Chill
and store until trayline.
• Eggs could be left to chill on perforated insert, drain well.
Scrambled Egg
A pasteurized egg product is recommended. Prepare to a soft, loose consistency.
Remove from heat source, cover with plastic wrap, and immediately blast chill.
Omelets
Frozen convenience product must be fully tempered prior to assembly. For omelets
prepared conventionally, follow existing standardized recipe. Omelet should be slightly
undercooked, then blast chilled.
Hard Cooked Egg
Cook in usual manner and chill immediately. Store covered in walk-in cooler.
PANCAKES/FRENCH TOAST/WAFFLES
For pancakes/French toast prepared conventionally, shingle, stack, and blast chill for a
short period of time (approximately 15 minutes). French toast made with Texas toast
blast chills and retherms with the best quality.
BREAKFAST MEAT
Sausage
Sausage patties are preferred over links for best heating. Cook sausage to 165° F.
(74° C.), then drain well. Blast chill.
Bacon
Cook to point of service. Presentation is best if bacon is cooked to the crisp stage,
drained, and patted dry with paper towels to remove excess fat. Blast chill.
Download from Www.Somanuals.com. All Manuals Search And Download.
[Page 40]
BREAKFAST BURRITOS/CREPES
Burrito and crepe filling is prepared conventionally and chilled. When filling is chilled,
then fill crepes and burritos. Blast chill filled products.
BREAKFAST SANDWICHES
Prepare sandwich filling separately and chill. Assemble sandwiches, wrap, and blast chill
for additional 15-20 minutes.
HASH BROWNS/OVEN FRIES
For both convenience and freshness, prepare to the point of complete doneness, then blast
chill. Product should not be too dry.
*Please note: The internal temperatures may continue to increase in the
beginning of the blast chill cycle.
Download from Www.Somanuals.com. All Manuals Search And Download.
|