Water Filtration Device
CHP-04AR/L/U
•
•
•
This product can not be used if the voltage is different from
that mentioned in the rating plate.
For your safety and proper use of the product, please read this
User’s Manual before use.
Warranty card is included in this User’s Manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
DEAR CUSTOMERS
Thank you for using Coway Water Filtration Device.
Please read this Users’Manual to use and maintain the product correctly.
If you encounter a problem while using the product, you may solve the problem referring to the
User’s Manual. As this manual contains the product warranty card, please keep it in a safe place.
This system (CHP-04AR/L/U) conforms to NSF/ANSI 42 for aesthetic chlorine reduction and NSF/
ANSI 53 for VOC reduction as verified and substantiated by test data.
This system (CHP-04AR/L) conforms to NSF/ANSI 58 for the reduction of pentavalent arsenic,
barium, cadmium, selenium, radium 226/228, trivalent chromium, hexavalent chromium, lead,
nitrate/nitrite as verified and substantiated by test data.
This system (CHP-04AR/L) registered in california.
See performance data sheet for individual contaminants and reduction performance.
This system (CHP-04AR/L) is acceptable for treatment for influent concentrations of no more
than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/
nitrite reduction only for water supplies with a pressure of 280 kPa(40 psi) or greater.
CONTENTS
FOR INFORMATION
HOW TO USE
SAFETy iNFORmATiON. . . . . . . . . . . . . . . . . . . 3
Electricity safety . . . . . . . . . . . . . . . . . . . . . . . 3
Installation safety. . . . . . . . . . . . . . . . . . . . . . 4
Operation safety. . . . . . . . . . . . . . . . . . . . . . . 5
Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
iNSTAllATiON PRECAUTiONS . . . . . . . . . . .13
iNdiCATORS ANd CONTROlS . . . . . . . . . . .15
HOW TO USE. . . . . . . . . . . . . . . . . . . . . . . . . . . .17
To drink the cold water. . . . . . . . . . . . . . . . 17
To drink the hot water . . . . . . . . . . . . . . . . 17
To drink the room water . . . . . . . . . . . . . . 18
PARTS NAmE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
WATER FilTRATiON PROCESS. . . . . . . . . . . . . 9
MAINTENANCE
OTHERS
iNSTAllATiON . . . . . . . . . . . . . . . . . . . . . . . . . .19
TROUblESHOOTiNG . . . . . . . . . . . . . . . . . . . .27
SPECiFiCATiONS . . . . . . . . . . . . . . . . . . . . . . . .28
WATER FlOW diAGRAm . . . . . . . . . . . . . . . . .29
PERFORmANCE dATA SHEET . . . . . . . . . . . .30
WARRANTy CARd. . . . . . . . . . . . . . . . . . . . . . .41
ClEANiNG mETHOd . . . . . . . . . . . . . . . . . . . .21
Storage tank. . . . . . . . . . . . . . . . . . . . . . . . . . 21
Gutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
FilTER REPlACEmENT. . . . . . . . . . . . . . . . . . .24
FilTER REPlACEmENT mETHOd . . . . . . . . .25
2
- Please keep the User’s manual where it can be readily reached or found -
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETy INFORMATION
Be careful to keep this safety information.
Please read this safety information carefully to ensure your safety and to prevent possible
property damage or loss.
If not observed,
serious injury or
even death could
occur.
If not observed,
serious injury or
property damage
could occur.
If not observed, slight
injury or property
damage could occur.
Danger
Warning
Caution
Electricity safety
do not use a damaged
power cord or plug, and
loose outlet.
Otherwise, electric shock or
fire may occur as a result.
do not pull the power
cord.
Otherwise, electric shock or
fire may occur as a result.
do not carry the unit by
its power cord.
do not touch the power
plug with a wet hand.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock or
fire may occur as a result.
do not forcefully bend
the power cord or put
it under a heavy object
to prevent it from being
damaged or deformed.
do not connect and
pull out the power plug
repeatedly.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock or
fire may occur as a result.
if the electric outlet is
wet, carefully unplug the
unit and let the electric
outlet completely dry
before subsequent use.
Unplug the product
before repair, inspection,
or parts replacement.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock or
fire may occur as a result.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Remove any dust or
water off in the pin and
contacts of the power
plug.
do not plug into an
outlet that is being
used by several other
appliances.
Otherwise, electric shock or
fire may occur as a result.
Use an electrical outlet
dedicated.
Otherwise, fire may occur as
a result.
When you don’t use for a
long time, close the main
water supply valve and
unplug.
Otherwise, electric shock or
fire may occur as a result.
do not attempt to repair
or modify the power cord
at your discretion.
Otherwise, electric shock or
fire may occur as a result.
in the case the power
cord is damaged, do
not replace the cord
yourself. Call Coway
Service Center to have it
replaced.
Otherwise, electric shock or
fire may occur as a result.
Installation safety
do not install near a
heating device.
Otherwise, fire may occur as
a result.
do not install the
product on a sloped
floor.
Injury to the user or damage
to the unit may result.
do not press the product
by constraint or impact.
Injury to damage to the unit
may result.
The filtration device installation shall
comply with applicable state and local
regulations.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETy INFORMATION
If not observed,
serious injury or
even death could
occur.
If not observed,
If not observed, slight
injury or property
damage could occur.
serious injury or
property damage
could occur.
Danger
Warning
Caution
Operation safety
When the water is
coming inside of the
product or there is a
puddle on the product,
call Service Center after
closing the supplying
valve and unplugging.
if our product produces a
strange noise or odd
smell, immediately
unplug from the
electrical outlet and call
our Service Center.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock may
occur as a result.
do not put the candle, a
light for cigarette on the
products.
Otherwise, fire may occur as
a result.
do not place any
containers with water,
medicine, food, small
metallic objects, or any
flammable material on
the top of the product.
In the case foreign material
gets inside the product,
electric shock, fire, product
damage may occur as a result.
Use after closing the
water tank cover
completely inside of the
product.
To drink the filtered
water, change the filter
according to the filter
replacement cycle.
The buck or the foreign body
can be entered.
If you use the expired filter,
the filter performance is
lowered.
When you don’t use for
a long time, use after
draining the saved
do not allow hot water to
come in contact with the
human body.
water completely and
emptying the newly
room water once again.
Otherwise, burn may occur
as a result.
The saved water can be
polluted.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Danger Warning Caution
Others
Clean after unplugging.
Otherwise, electric shock or
fire may occur as a result.
do not clean by spraying
the water directly or
don’t wipe the product
using the benzene and
thinner.
Otherwise, electric shock or
fire may occur as a result.
do not repair,
do not use filtered water
for the water exchange
of an aquarium or a
fishbowl.
The room water through the
membrane isn’t suitable for
the fish’s life environment as
it removed the ionic material.
In some cases, fishes might
even die.
disassemble, or modify.
Otherwise, electric shock or
product damage may occur
as a result.
After moving the product
or replacing the inno-
sense filter, the black
powder can be remained
in the inner bottom of
the water tank.
do not use with water
that is microbiologically
unsafe or of unknown
quality without adequate
disinfection before or
after the system.
It is quiet harmless as the
powder of the activated
carbon used in the inno-sense
filter was flowed out for
improving the water tastes.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS NAME
Front
Indicators
Controls
Hot water Faucet
Cold / Room water
Changeover Faucet
Cup-touch Lever
Gutter
Front Draining Door
Front Cover
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear
Top Cover
Rear Cover
Power Cord
Drain Hose
Cooling Stopper
Outlet (Blue, CHP-04AR/L)
Inlet(Orange)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER FILTRATION PROCESS
The filter is the core technology of the filtration system.
If you don’t use qualifying filter or if you use an old filter that has expired, the system
performance may degrade.
The 5-step water filtering system (CHP-04AR/L)
Step 1 : PlUS SEdimENT FilTER
This plus sediment filter has the functions to reduce infusible particles from feed water and to
protect membrane and pre-carbon filter from being plugged.
Step 2 : PRE-CARbON FilTER
This Pre-Carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic
compounds(VOC’s).
Step 3 : RO mEmbRANE FilTER
RO membrane filter has the function to reduce water contaminants such as pentavalent arsenic,
barium, cadmium, selenium, radium 226/228, trivalent chromium, hexavalent chromium, lead,
nitrate/nitrite.
Step 4 : iNNO SENSE FilTER
This inno-sense filter has the functions to reduce smell induction material and to improve taste of
water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).
STEP 5 : UlTRA-ViOlET lAmP
This ultra-violet lamp circulates the treated water inside the reservoir tank.
PLUS SEDIMENT
FILTER
PRE-CARBON
FILTER
RO MEMBRANE
FILTER
INNO SENSE
FILTER
ULTRA-VIOLET
LAMP
Reject
Water
Outlet
Uses of reject water
-
The reject water should be used for cleaning the restroom, the house, clothes, or
purposes other than drinking.
Tips
-
Never use the reject water for a drinking or a cooking.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
The 6-step water filtering system (CHP-04AR/L)
Step 1 : PlUS SEdimENT FilTER
This plus sediment filter has the functions to reduce infusible particles from feed water and to
protect membrane and pre-carbon filter from being plugged.
Step 2 : PRE-CARbON FilTER
This Pre-Carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic
compounds(VOC’s).
Step 3 : RO mEmbRANE FilTER
RO membrane filter has the function to reduce water contaminants such as pentavalent arsenic,
barium, cadmium, selenium, radium 226/228, trivalent chromium, hexavalent chromium, lead,
nitrate/nitrite.
Step 4, 5 : FiNE POST-CARbON FilTER
This Fine Post-Carbon filter has the functions to reduce smell induction material and to improve taste
of water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).
STEP 6 : UlTRA-ViOlET lAmP
This ultra-violet lamp circulates the treated water inside the reservoir tank.
PLUS SEDIMENT
FILTER
PRE-CARBON
FILTER
RO MEMBRANE FINE POST-CARBON
FILTER FILTER
CERAMIC
FILTER
Reject
Water
Outlet
10
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER FILTRATION PROCESS
The 5-step water filtering system (CHP-04AU)
Step 1 : PlUS SEdimENT FilTER
This plus sediment filter has the functions to reduce infusible particles from feed water and to
protect membrane and pre-carbon filter from being plugged.
Step 2 : PRE-CARbON FilTER
This Pre-Carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic
compounds(VOC’s).
Step 3 : iNNO SENSE FilTER
This inno-sense filter has the functions to reduce smell induction material and to improve taste of
water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).
Step 4 : UF mEmbRANE FilTER
STEP 5 : UlTRA-ViOlET lAmP
This ultra-violet lamp circulates the treated water inside the reservoir tank.
PLUS SEDIMENT
FILTER
PRE-CARBON
FILTER
INNO SENSE
FILTER
UF MEMBRANE
FILTER
ULTRA-VIOLET
LAMP
11
Download from Www.Somanuals.com. All Manuals Search And Download.
The 5-step water filtering system (CHP-04AU)
Step 1 : PlUS SEdimENT FilTER
This plus sediment filter has the functions to reduce infusible particles from feed water and to
protect membrane and pre-carbon filter from being plugged.
Step 2 : PRE-CARbON FilTER
This Pre-Carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic
compounds(VOC’s).
Step 3 : POST-CARbON FilTER
This post-carbon filter has the functions to reduce smell induction material and to improve taste of
water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).
Step 4 : UF mEmbRANE FilTER
STEP 5 : UlTRA-ViOlET lAmP
This ultra-violet lamp circulates the treated water inside the reservoir tank.
PLUS SEDIMENT
FILTER
PRE-CARBON
FILTER
POST-CARBON
FILTER
UF MEMBRANE
FILTER
ULTRA-VIOLET
LAMP
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION PRECAUTIONS
The summary for the proper installation of the water filtration device
1. Close main water supply valve to separate the faucet.
2. Apply the teflon tape on the adaptor and fit it to the
pipe.
do not turn the water pipe.
3. Connect the faucet with the adaptor.
install the adaptor with connector to the cold water pipe.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
Flush water through each filter at least 5 minutes before
Connection.
5. Open the feed valve to supply water to the filtration
system.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Please check before use!
This product is for 120 V 60 Hz only.
Please connect the power plug to a grounded electrical outlet for 120
V
60 Hz. The water filtration device works normally only when the
electricity is connected.
• Open the main water supply valve.
The main water must be supplied to operate the water filtration device normally.
• After installing the product
Get rid of the saved water above the full water in the inner water tank 2 times or more to use.
• When the indicator in the indication part is turned off
When the indicator in the indication part is turned off, check if the power supply was stopped
due to the power failure or other cause.
• Regular filter replacement
It is important to replace the filter regularly to maintain water quality as it is designed. If the filter
is overused beyond its service life, the performance of the water filtration device deteriorate. Do
not miss the filter replacement cycle.
• When you didn’t use for a long time
If you saved the water for a long time or you didn’t use, drain the water inside of the water
filtration device completely and remove the newly filtered water one time to use.
• When you don’t want to use the product for a long time.
Close the main water supply valve and unplug the power cord.
When you don’t use for a long time, close the main water supply valve and unplug the
power cord.
Tips
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INDICATORS AND CONTROLS
Indication part/Operation part
Indicators
Controls
Water level
indicator
Hot water
temperature
indicator
3
6
Power
indicator
1
2
UV cycle
indicator
Cold water
temperature
indicator
Hot water
temperature
level indicator
7
8
Hot water
mode
indicator
4
5
1
Cold water
mode
indicator
Cold water
temperature
level indicator
9
Hot water mode
selection button
Cold water mode
selection button
2
1
2
Power indicator
UV cycle indicator
If you connect the power,
the indicator is turned on.
In case that storage tank is full
for a hour,“UV”lamp lights on
and lamp lights off in serial.
in case that“UV”lamp blinks,
change the UV lamp.
3
5
4
Water level indicator
Hot water mode
indicator
When you select hot water
mode, the indicator is
turned on.
The indicator is turned on
according to the water level
in the storage tank. Basically,
one blank is turned on.
Cold water mode
indicator
6
Hot water temperature
indicator
When you select cold water
mode, the indicator is
turned on.
The indicator is turned on
according to the hot water
temperature. The more LEDs
are on, the higher the hot water
temperature is.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
7
8
Hot water
Cold water
temperature indicator
The indicator is turned on
according to the cold water
temperature. The more LEDs
are on, the lower the cold water
temperature is.
temperature level
indicator
The indicator is controlled
by hot water mode
selection button.
9
1
Cold water temperature
level indicator
The indicator is controlled by cold
water mode selection button.
Hot water mode
selection button
To select/deselect hot water
mode.
2
Cold water mode
selection button
To select/deselect cold
water mode.
To use cold water mode
Press cold water mode selection button and check if
cold water mode indicator is turned on. If you want to
turn off cold water mode, press selection button for
about 3 seconds or more. In statement of cold water
selection, water level is changed in order of H L M
H whenever you press the button shortly.
When you are using the product for the first time,
or if the cold water feature is off for a long time,
then it takes about an hour for the water to reach a
preset cold water temperature.
To use hot water mode
Press hot water mode selection button and check if
hot water mode indicator is turned on. If you want to
turn off hot water mode, press selection button for
about 3 seconds or more. In statement of hot water
selection, water level is changed in order of H L M
H whenever you press the button shortly.
When you are using the product for the first time,
or if the hot water feature is off for a long time, then
it takes about 30 minutes for the water to reach a
preset hot water temperature.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO USE
To drink the cold water
You can drink the cold water when you turn the jog
shuttle to the left in cold water/room water changeover
faucet and pushing the cup-touch lever.
If the cold water doesn’t come from the water filtration device, check if the cold water
mode indicator is turned on (See P.16).
Tips
To drink the hot water
If you press the hot water safety button and push the
cup-touch lever, you can drink the hot water.
If the cold water doesn’t come from the water filtration device, check if the cold water
mode indicator is turned on (See P.16).
Tips
17
Download from Www.Somanuals.com. All Manuals Search And Download.
To drink the room water
You can drink the room water when you turn the
jog shuttle to the right in cold water/room water
changeover faucet and push the cup-touch lever.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Follow the instruction for installation
Main water
supply valve
2 cooling stopper
120 V~ 60 Hz Only
1
Connect the orange color inlet tubing to the tap water
2
supplying pipe. Connect the outlet tubing
.
Inlet tubing (Orange)
Outlet tubing
2
(Blue, CHP-04AR/L)
1
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Be cautious!
Water filtration device installation place 1
Please install the water filtration system not at a rough place, a damp
place, a place where the unit is exposed to the direct sunlight, a
place where dust is present, or a place that the water drops.
Water filtration device installation place 2
Please install at the place where it is 10 cm or more off from the wall
and the bottom is flat and firm.
After installing the water filtration system
Please empty the water tank filled with filtered water two times after
the product installation.
Hot
Cold water plumbing
W a ter
Please connect the source water. Make sure that the source water is
not from hot water line. If you use hot water as source water, then
it will cause permanent damages to RO membrane and severely
degrade the product performance.
movement and installation
When the position is moved, connect the power cord when 30
minutes passes after installing.
To maintain optimal product performance, consult a Coway engineer for the detailed
installation methods.
Tips
There may be some water remaining inside of the filter which was used to test the
product during inspection process at the factory.
Please feel at easy and use as it isn’t the used product.
Don’t reuse the main water supply valve and hose that was previously used when you
re-install the product.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING METHOD
Storage tank
1. Turn off by pressing cold water / hot water
mode selection button in the front of the
product for 3 seconds or more and unplug.
Please lock the main water supply valve.
2. Please empty the water tank completely using
the draining hose after pressing and letting
down the front draining door.
Drain the water in Cold water/Room water tank from the
upper blue cover, and drain the water in Hot water tank
from the lower red cover.
3. Please remove the top cover, and then un-hook the fixed clip holding the
top cover of the water tank. Now remove hose and open the tank cover.
4. Wipe the surface of the storage tank with soft clothes.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Use the storage tank after
cleaning it with the drained
water, and empty the water
tank using the draining hose.
After cleaning, please close
both tank and top cover, then
empty the water tank filled
with filtered water one more time.
6. Open the main water supply valve after closing
the water tank cover, upper cover and plugging
the power cord.
Please operate the water filtration device
again by pressing cold water / hot water mode
selection button in the front of the product
after checking if the water is coming from the
cold water/the room water extraction faucet and the hot water extraction
faucet.
Close the storage tank cover completely.
Insects or other foreign particles can be entered.
When you clean the storage tank, don’t use any chemicals or
Tips
detergent.
If you don’t clean chemicals or detergent cleanly, it can be harmful
to the body.
-
Keep the surroundings clean and clean the storage tank once
per two months.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING METHOD
Gutter
1. Gutter separation method
After leaning the gutter forward and taking in from the
product, Separate the gutter cover.
2. Gutter assembling method
After assembling the gutter and the gutter cover, insert
the assembled gutter into below the product.
For the product installed the draining hose, you don’t need to empty the gutter
additionally.
Tips
23
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER REPLACEMENT
Filter
Filter is a critical component for a water filtration system. Replacing
authorized filters at a specified replacement cycle is important to maintain
the water quality, and a proper system operation. Please replace filters at a
specified replacement cycle. For replacement filters, please contact Coway
authorized dealers and distributors.
Filter replacement cycle
If the filter is not regularly replaced, it may degrade the water quality from
the product. The source water quality can shorten the filter replacement
period.
The period for the filter exchange is made based on 10 L use in a day for
house use(4 people based) and 20 L use for business.
CHP-04AR/L
Part No.
WJSF14-PLUS
WJCF14-PRE
WJMF14-75
WJMF14-50
Names of Filter
Plus sediment filter
Replacement Cycle
6 months
Pre-carbon filter
12 months
RO Membrane filter(CHP-04AR)
RO Membrane filter(CHP-04AL)
24 months
24 months
WJIF14
/ WJFCF14-POST
Inno-sense filter
/ Fine post-carbon filter
18 months
12 months
WJUVF-4W-PUMP
Ultra-violet filter
CHP-04AU
Part No.
Names of Filter
Plus sediment filter
Pre-carbon filter
Replacement Cycle
6 months
WJSF14-PLUS
WJCF14-PRE
12 months
WJIF14
/WJCF14-POST
Inno-sense filter
/ Post-carbon filter
18 months
WJMF14-UF
UF Membrane filter
Ultra-violet filter
12 months
12 months
WJUVF-4W-PUMP
About filter replacement cycle
The filter replacement cycle described above is not the filter quality
warranty period but the expected cycle (life) that the filter shows its
original performance.
Therefore, the filter replacement cycle may be reduced for the area with
the poor water quality or more water consumption.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER REPLACEMENT METHOD
1. Close the main water supply valve after unplugging the power cord, and
drain the water inside of the water filtration device (See P.21).
2. Open by pressing the front draining cover and release 1 fixed screw using
the Philips driver.
Separate the front cover under the product by pressing and pulling
forward.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
3. After separating the fitting connected to the filter to replace, please
replace the filter.(Separate the fitting using the proper tool.)
When you are replacing filters, please make sure that a corresponding filter and a
hose are firmly connected and that there is no leakage.
It is recommended to empty the water tank filled with the filtered water at least one
Tips
time right after the filter replacement.
4. Please fit the groove of the front cover.
After tightening 1 fixed screw in the front
draining part using the Phillips driver, let
down and close the front draining door.
Before installing a new filter, please do the filter cleansing first as directed below:
Filter Name
Cleansing Time
Comment
Tips
Plus sediment filter
30 seconds
Pre-carbon / Inno-
sense / Post carbon
/ Fine post carbon
filter
Please use plus sediment filtered water for
cleansing
3 minutes
3 minutes
Please use plus sediment filtered water for
cleansing
Ro membrane filter
26
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
The water filtration device may operate abnormally due to minor causes not because of the
product malfunction but because of the fact that the user is not familiar with the product use.
In such a case, problems can be solved easily even without the help from the Service Center by
checking the following items. If you can’t solve the problem after checking the following items,
please call the Service Center.
Symptom
Check
Measures to take
Clean the storage tank.
•
•
Did you clean the storage tank?
The water tastes
weird.
You didn’t use the water filtration device Get rid of the saved water and clean the
for a long time.
storage tank.
•
•
Isn’t it about time to change the filter?
Request the filter replacement.
Is the water supply cut or isn’t the water
supply valve closed?
Open the main water supply valve.
The water doesn’t
come.
•
•
Did you miss the filter replacement times? Request the filter replacement.
Isn’t it about time to change the filter?
Is the power connected?
Request the filter replacement.
Check if the power cord plug in 120 V 60
Hz outlet.
•
•
The water is
flowing slower.
Didn’t you close the main water supply
valve?
Open the main water supply valve.
•
•
Didn’t the temperature of the main water If the water temperature is lowered, the
drop suddenly?
water amount is decreased.
Was the cold water mode indicator
lightened?
Please press the cold water mode selection
button.
If it is the low water level to protect the
electric motor, the cooling function doesn’t
operate. Open the main water supply valve.
The cold water /
hot water doesn’t
come.
•
•
Didn’t you close the main water supply
valve?
Please keep the distance between the back
of the water filtration device and the wall to
10 cm or more.
Isn’t the back side of the water filtration
device and the wall too close?
•
•
•
Is the main water being supplied actively? Check the main water supply valve.
All operation was
stopped suddenly
when driving.
Check if the power cord plug in 120 V 60
Is the power connected?
Hz outlet.
Isn’t water overflowing or leaking?
Request A/S.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATION
Product
Water Filtration Device
Model
CHP-04AR
CHP-04AL
CHP-04AU
UF
Filtration Method
Power Supply
RO(Reverse Osmosis)
120 V 60 Hz
Room Water
14 L
Cold Water
Hot Water
Total
3 L
Tank
Capacity
3.6 L
22.4 L
380 mm(W) × 437 mm(D) × 1 257 mm(H)
5 °C - 35 °C
Dimension
Working Temperature
Production Rate
Working Pressure
Net Weight
284 L/d(25 °C, 414 kPa)
69 kPa – 827 kPa
38.6 kg
190 L/d(25 °C, 138 kPa)
138 kPa – 827 kPa
36.5 kg
1 500 L/d(25 °C, 108 kPa)
69 kPa – 827 kPa
36.5 kg
•
•
•
•
The water amount can be differentiated according to the water pressure and the water
temperature.
The water tank capacity is the amount by the size and can be different from the extraction
capacity.
Without any prior notice, all or parts of the product are subject to change for the purpose of
improving the performance of the product.
Refer to Performance data sheet for individual contaminants, reduction performance and general
operating information.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER FLOW DIAGRAM
CHP-04AR
CHP-04Al
CHP-04AU
•
An fine post carbon filter(post carbon filter) may be installed instead of a inno-sense filter.
For the precise specifications of your product, refer to the data plate on the product.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Filtration System Performance data Sheet
brand: metro
model: CHP-04AR
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42, 53, and 58.
Max. Allowable
Concentration
(mg/L)
0.010
Average
Influent
(mg/L)
0.05
Average
Effluent
(mg/L)
0.006
1.4
Minimum
Percent
Reduction (%)
79.1
Average
Percent
Reduction (%)
87.7
Substance
Arsenic (Pentavalant)
Barium
2.0
10
83.5
86.6
Radium 226/228
Cadmium
Chromium (Hexavalent)
Chromium (Trivalent)
Lead
5pCi/L
0.005
0.1
0.1
0.010
10
0.05
<187.5
25pCi/L
0.031
0.358
0.367
0.153
29.6
5pCi/L
0.002
0.023
0.028
0.005
4.8
N/A
89.0
93.8
93.8
93.6
78.5
96.0
97.3
N/A
92.7
95.1
95.7
95.1
83.7
97.8
98.0
Nitrate/Nitrite
Selenium
0.117
741.5
0.003
14.5
TDS
Aesthetic Chlorine
INNOSENSE
FINE POST CARBON
≥ 50%
≥ 50%
2.07
1.96
0.56
0.53
54.53
55.0
72.8
72.8
VOC*
INNOSENSE
FINE POST CARBON
≥ 95% reduction
≥ 95% reduction
0.327
0.317
0.0052
0.005
96.20
96.2
98.4
98.5
While testing was performed under laboratory conditions, actual performance may vary.
General Operating information:
359 gallons (for VOC)
7,523 gallons (for Aesthetic Chlorine)
INNOSENSE FILTER
Rated Capacity
402 gallons (for VOC)
1,453 gallons (for Aesthetic Chlorine)
POST-CARBON FILTER
Min-Max operating pressure:
Min-Max feed water temperature:
10 ~ 120 psi (0.7 ~ 8.4 kgf/cm2)
41 ~ 95 ºF (5 ~ 35 ºC)
0.07 GPM (for VOC)
0.5 GPM (for Aesthetic Chlorine)
86.2 GPD
Rated Service Flow
Daily Water Production Rate
Product Efficiency Rating
38.7 %
Electrical Requirements:
120 Vac / 60Hz
•
•
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
The influent water to the system shall include the following characteristics:
o
o
o
o
o
o
o
No organic solvents
Chlorine: < 2 ppm
pH: 7 - 8
Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
Iron: < 2 ppm
Turbidity: < 1 NTU
Hardness: < 1000 mg/L
30
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
For parts and service availability, please contact your local dealer or Coway.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L
nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a
pressure of 2.8 kgf/cm2 (40 psi) or greater.
•
•
A nitrate/nitrite sampling kit should be used to monitor the nitrate/nitrite levels in your product drinking water
at least every six months. Kits maybe purchased from your local dealer or Coway.
This system has been tested for the treatment of water containing pentavalent arsenic (also know as As(V),
As(+5), or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but
may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable
free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete
conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of this Performance
Data Sheet for further information.
•
•
•
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse
osmosis treated water under operating conditions that approximate typical daily usage.
The product water should be tested every 6 months to ensure that the contaminants are being reduced
effectively. Please contact your local dealer or Coway to initiate this service.
This reverse osmosis system contains a replaceable treatment components, critical for the effective reduction of
total dissolved solids and that product water shall be tested periodically to verify that the system is performing
properly. Replacement of reverse osmosis component should be with one of identical specifications, as defined
by the manufacturer, to assure the same efficiency and contaminant reduction performance.
The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee
period, but it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement
may be shortened in case it is used in an area of poor water quality.v
•
Model of Filter
WJSF14-PLUS
WJCF14-PRE
WJMF14-75
Type
Usable period (months)
COST US $
32.00
PLUS SEDIMENT FILTER
PRE-CARBON FILTER
RO MEMBRANE FILTER
6
12
24
36.00
156.00
WJIF14
/ WJFCF14-POST
INNO SENSE FILTER
/ FINE POST-CARBON FILTER
18
12
47.00
WJUVF-4W-PUMP
ULTRA-VIOLET LAMP
187.00
ARSENiC FACTS
Arsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must
be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results
from your water utility. If you have your own well, you can have the water tested. The local health department
or the state environmental health agency can provide a list of certified labs. The cost is typically $15 to $30.
Information about arsenic in water can be found on the Internet at the US Environmental Protection Agency
website:
There are two forms of arsenic: pentavalent arsenic (also called As(V), As(+5), and arsenate) and trivalent arsenic
(also called As(III), As(+3), and arsenite). In well water, arsenic may be pentavalent, trivalent, or a combination of
both. Special sampling procedures are needed for a lab to determine what type and how much of each type of
arsenic is in the water. Check with the labs in your area to see if they can provide this type of service.
Reverse osmosis (RO) water treatment systems do not remove trivalent arsenic from water very well. RO systems
are very effective at removing pentavalent arsenic. A free chlorine residual will rapidly convert trivalent arsenic
to pentavalent arsenic. Other water treatment chemicals such as ozone and potassium permanganate will also
change trivalent arsenic to pentavalent arsenic. A combined chlorine residual (also called chloramine) may not
convert all the trivalent arsenic. If you get your water from a public water utility, contact the utility to find out if free
chlorine or combined chlorine is used in the water system.
The CHP-04AR system is designed to remove pentavalent arsenic. It will not convert trivalent arsenic to pentavalent
arsenic. The system was tested in a lab. Under those conditions, the system reduced 0.050 mg/L pentavalent
arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water) or less. The performance of the system may be
different at your installation. Have the treated water tested for arsenic to check if the system is working properly.
The RO component of the CHP-04AR system must be replaced every 24 months to ensure the system will
continue to remove pentavalent arsenic. The component identification and locations where you can purchase the
component are listed in the installation/operation manual.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
State of California
Department of Public Health
Water Treatment device
Certificate Number
08 - 1905
Date Issued: June 24, 2008
Trademark/model designation
Replacement Element(s)
Metro CHP-04AR
WJSF14-PLUS Plus Sediment Filter
WJCF14-PRE Pre-carbon Filter
WJMF14-75 RO Membrane Filter
WJFCF14-POST Post-carbon Filter
WJUVF-4W-PUMP UV Bulb
Manufacturer: Woongjin Coway Co LTD
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health
and Safety Code for the following health related contaminants:
microbiological Contaminants and Turbidity
inorganic/Radiological Contaminants
Arsenic (Pentavalent)1
Barium
None
Cadmium
Chromium (Hexavalent)
Chromium (Trivalent)
Lead
Nitrate/Nitrite2
Radium 226/228
Selenium
Organic Contaminants
VOCs
Alachlor
Endrin
Simazine
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorobenzene
Chloropicrin
2,4-D
DBCP
o-Dichlorobenzene
p-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropylene
Dinoseb
Ethylbenzene
EDB
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
Haloacetonitriles (HAN)
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
2,4,5-TP (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (THMs)
Bromodichloromethane
Bromoform
Chloroform
Chlorodibromomethane
Xylenes
Methoxychlor
Pentachlorophenol
Rated Service Capacity: 359 gal
Rated Service Flow: 0.07 gpm
do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1 Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the
reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1 minute
chlorine contact time before the RO system.
2 This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in
combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa
(40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system.
Frequent analysis is encouraged.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Filtration System Performance data Sheet
brand: metro
model: CHP-04Al
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42, 53, and 58
Max. Allowable
Concentration
(mg/L)
0.010
Average
Influent
(mg/L)
0.05
Average
Effluent
(mg/L)
0.006
1.4
Minimum
Percent
Reduction (%)
79.1
Average
Percent
Reduction (%)
87.7
Substance
Arsenic (Pentavalant)
Barium
2.0
10
83.5
86.6
Radium 226/228
Cadmium
Chromium (Hexavalent)
Chromium (Trivalent)
Lead
5pCi/L
0.005
0.1
0.1
0.010
10
0.05
<187.5
25pCi/L
0.031
0.358
0.367
0.153
29.6
5pCi/L
0.002
0.023
0.028
0.005
4.8
N/A
89.0
93.8
93.8
93.6
78.5
96.0
90.0
N/A
92.7
95.1
95.7
95.1
83.7
97.8
92.6
Nitrate/Nitrite
Selenium
0.117
741.5
0.003
55.1
TDS
Aesthetic Chlorine
INNOSENSE
FINE POST CARBON
VOC*
≥ 50%
≥ 50%
2.07
1.96
0.56
0.53
54.53
55.0
72.8
72.8
INNOSENSE
FINE POST CARBON
≥ 95% reduction
≥ 95% reduction
0.327
0.317
0.0052
0.005
96.20
96.2
98.4
98.5
While testing was performed under laboratory conditions, actual performance may vary.
General Operating information:
359 gallons (for VOC)
INNOSENSE FILTER
7,523 gallons (for Aesthetic Chlorine)
Rated Capacity
402 gallons (for VOC)
1,453 gallons (for Aesthetic Chlorine)
FINE POST-CARBON
Min-Max operating pressure:
Min-Max feed water temperature:
20 ~ 120 psi (14 ~ 8.4 kgf/cm2)
41 ~ 95 ºF (5 ~ 35 ºC)
0.07 GPM (for VOC)
0.5 GPM (for Aesthetic Chlorine)
53.3 GPD
Rated Service Flow
Daily Water Production Rate
Product Efficiency Rating
Electrical Requirements:
31.0 %
120 Vac / 60Hz
•
•
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
The influent water to the system shall include the following characteristics:
o
o
o
o
o
o
o
No organic solvents
Chlorine: < 2 ppm
pH: 7 - 8
Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
Iron: < 2 ppm
Turbidity: < 1 NTU
Hardness: < 1000 mg/L
33
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
For parts and service availability, please contact your local dealer or Coway.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L
nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a
pressure of 2.8 kgf/cm2 (40 psi) or greater.
•
•
A nitrate/nitrite sampling kit should be used to monitor the nitrate/nitrite levels in your product drinking water
at least every six months. Kits maybe purchased from your local dealer or Coway.
This system has been tested for the treatment of water containing pentavalent arsenic (also know as As(V),
As(+5), or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but
may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable
free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete
conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of this Performance
Data Sheet for further information.
•
•
•
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse
osmosis treated water under operating conditions that approximate typical daily usage.
The product water should be tested every 6 months to ensure that the contaminants are being reduced
effectively. Please contact your local dealer or Coway to initiate this service.
This reverse osmosis system contains a replaceable treatment components, critical for the effective reduction of
total dissolved solids and that product water shall be tested periodically to verify that the system is performing
properly. Replacement of reverse osmosis component should be with one of identical specifications, as defined
by the manufacturer, to assure the same efficiency and contaminant reduction performance.
The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee
period, but it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement
may be shortened in case it is used in an area of poor water quality.
•
Model of Filter
WJSF14-PLUS
WJCF14-PRE
WJMF14-50
Type
Usable period (months)
COST US $
32.00
PLUS SEDIMENT FILTER
PRE-CARBON FILTER
RO MEMBRANE FILTER
6
12
24
36.00
145.00
WJIF14
/ WJFCF14-POST
INNO SENSE FILTER
/ FINE POST-CARBON FILTER
18
12
47.00
WJUVF-4W-PUMP
ULTRA-VIOLET LAMP
187.00
ARSENiC FACTS
Arsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must
be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results
from your water utility. If you have your own well, you can have the water tested. The local health department
or the state environmental health agency can provide a list of certified labs. The cost is typically $15 to $30.
Information about arsenic in water can be found on the Internet at the US Environmental Protection Agency
website:
There are two forms of arsenic: pentavalent arsenic (also called As(V), As(+5), and arsenate) and trivalent arsenic
(also called As(III), As(+3), and arsenite). In well water, arsenic may be pentavalent, trivalent, or a combination of
both. Special sampling procedures are needed for a lab to determine what type and how much of each type of
arsenic is in the water. Check with the labs in your area to see if they can provide this type of service.
Reverse osmosis (RO) water treatment systems do not remove trivalent arsenic from water very well. RO systems
are very effective at removing pentavalent arsenic. A free chlorine residual will rapidly convert trivalent arsenic
to pentavalent arsenic. Other water treatment chemicals such as ozone and potassium permanganate will also
change trivalent arsenic to pentavalent arsenic. A combined chlorine residual (also called chloramine) may not
convert all the trivalent arsenic. If you get your water from a public water utility, contact the utility to find out if free
chlorine or combined chlorine is used in the water system.
The CHP-04AL system is designed to remove pentavalent arsenic. It will not convert trivalent arsenic to pentavalent
arsenic. The system was tested in a lab. Under those conditions, the system reduced 0.050 mg/L pentavalent
arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water) or less. The performance of the system may be
different at your installation. Have the treated water tested for arsenic to check if the system is working properly.
The RO component of the CHP-04AL system must be replaced every 24 months to ensure the system will
continue to remove pentavalent arsenic. The component identification and locations where you can purchase the
component are listed in the installation/operation manual.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
State of California
Department of Public Health
Water Treatment device
Certificate Number
08 - 1904
Date Issued: June 24, 2008
Trademark/model designation
Replacement Element(s)
Metro CHP-04AL
WJSF14-PLUS Plus Sediment Filter
WJCF14-PRE Pre-carbon Filter
WJMF14-50 RO Membrane Filter
WJFCF14-POST Post-carbon Filter
WJUVF-4W-PUMP UV Bulb
Manufacturer: Woongjin Coway Co LTD
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health
and Safety Code for the following health related contaminants:
microbiological Contaminants and Turbidity
None
inorganic/Radiological Contaminants
Arsenic (Pentavalent)1
Barium
Cadmium
Chromium (Hexavalent)
Chromium (Trivalent)
Lead
Nitrate/Nitrite2
Radium 226/228
Selenium
Organic Contaminants
VOCs
Alachlor
Endrin
Simazine
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorobenzene
Chloropicrin
2,4-D
DBCP
o-Dichlorobenzene
p-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropylene
Dinoseb
Ethylbenzene
EDB
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
Haloacetonitriles (HAN)
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
2,4,5-TP (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (THMs)
Bromodichloromethane
Bromoform
Chloroform
Chlorodibromomethane
Xylenes
Methoxychlor
Pentachlorophenol
Rated Service Capacity: 359 gal
Rated Service Flow: 0.07 gpm
do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1 Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the
reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1minute
chlorine contact time before the RO system.
2 This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in
combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with apressure of 280 kPa
(40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system.
Frequent analysis is encouraged.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Filtration System Performance data Sheet
brand: metro
model: CHP-04AU
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, and 53 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53
Max. Allowable
Concentration
(mg/L)
Minimum
Percent
Reduction (%)
Average Influent Average Effluent
Average Percent
Reduction (%)
Substance
(mg/L)
(mg/L)
Aesthetic Chlorine
INNOSENSE
POST CARBON
VOC*
≥ 50%
≥ 50%
2.07
1.96
0.56
0.53
54.53
55.0
72.8
72.8
INNOSENSE
POST CARBON
≥ 95% reduction
≥ 95% reduction
0.327
0.317
0.0052
0.005
96.20
96.2
98.4
98.5
While testing was performed under laboratory conditions, actual performance may vary.
General Operating information:
359 gallons (for VOC)
INNO SENSE FILTER
7,523 gallons (for Aesthetic Chlorine)
Rated Capacity
402 gallons (for VOC)
1,453 gallons (for Aesthetic Chlorine)
POST-CARBON FILTER
Min-Max operating pressure:
10 ~ 120 psi (0.7 ~ 8.4 kgf/cm2)
41 ~ 95 ºF (5 ~ 35 ºC)
Min-Max feed water temperature:
0.07 GPM (for VOC)
0.5 GPM (for Aesthetic Chlorine)
Rated Service Flow
Electrical Requirements:
120 Vac / 60Hz
•
•
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
For parts and service availability, please contact your local dealer or Coway.
Model of Filter
WJSF14-PLUS
WJCF14-PRE
Type
Usable period (months)
COST US $
32.00
PLUS SEDIMENT FILTER
PRE-CARBON FILTER
6
12
36.00
WJIF14
/ WJCF14-POST
INNO SENSE FILTER
/ POST-CARBON FILTER
18
47.00
WJMF14-UF
UF MEMBRANE FILTER
ULTRA-VIOLET LAMP
12
12
59.00
WJUVF-4W-PUMP
187.00
36
Download from Www.Somanuals.com. All Manuals Search And Download.
* VOC Surrogate Claims
Drinking water regulatory
Influent challenge
Chemical reduction
percent
Maximum product water
concentration mg/L
Chemical
level1 (MCL/MAC) mg/L
concentration2 mg/L
alachlor
atrazine
0.002
0.003
0.005
0.04
0.005
0.1
0.050
0.100
0.081
0.190
0.078
0.077
0.015
0.110
0.052
0.080
0.040
0.088
0.083
0.170
0.086
0.080
0.079
0.170
0.053
0.088
0.044
> 98
> 97
> 99
> 99
98
0.0013
0.0033
0.0013
0.0013
0.00184
0.0013
0.00023
0.00174
0.000023
0.0013
0.0013
0.00485
0.0013
benzene
carbofuran
carbon tetrachloride
chlorobenzene
> 99
99
chloropicrin
-
2,4-D
0.07
0.0002
0.6
98
dibromochloropropane(DBCP)
o-dichlorobenzene
p-dichlorobenzene
1,2-dichloroethane
1,1-dichloroethylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
1,2-dichloropropane
cis-1,3-dichloropropylene
dinoseb
> 99
> 99
> 98
955
0.075
0.005
0.007
0.07
0.1
> 99
> 99
> 99
> 99
> 99
99
0.00053
0.0013
0.0013
0.005
-
0.0013
0.007
0.002
0.7
0.00024
0.000594
0.0013
endrin
99
ethylbenzene
> 99
> 99
ethylene dilbromide (EDB)
0.00005
0.000023
haloacetonitriles (HAN):
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetoritrile
-
-
-
-
0.022
0.024
0.0096
0.015
98
98
98
98
0.00053
0.00063
0.00023
0.00033
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
-
-
0.0072
0.0082
99
96
0.00013
0.00033
heptachlor (H-34,Heptox)
heptachlor epoxide
hexachlorobutadiene
hexachlorocyclopentadiene
lindane
0.0004
0.0002
-
0.08
0.01076
> 99
98
0.0004
0.00026
0.0013
0.0000023
0.000013
0.00013
0.0013
0.0043
0.00053
0.0013
0.044
> 98
> 99
> 99
> 99
> 99
> 97
> 99
> 99
> 99
> 99
99
0.05
0.0002
0.04
0.001
0.004
0.1
0.060
0.055
methoxychlor
0.050
pentachlorophenol
simazine
0.096
0.120
styrene
0.150
1,1,2,2-tetrachloroethane
tetrachloroethylene
toluene
-
0.081
0.005
1
0.081
0.0013
0.0013
0.078
2,4,5-TP (silvex)
0.05
-
0.270
0.00164
0.0013
0.00053
0.00464
0.00053
0.00103
tribromoacetic acid
1,2,4-trichlorobenzene
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
0.042
> 98
> 99
95
0.07
0.2
0.160
0.084
0.005
0.005
0.150
0.180
> 99
> 99
trihalomethanes (includes):
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.080
10
0.300
0.070
95
0.015
xylenes (total)
> 99
0.0013
1. These harmonized values were agreed upon by representatives of USEPA and Health Canada for the purpose of evaluating products to the requirements of
this Standard.
2. Influent challenge levels are average influent concentrations determined in surrogate qualification testing.
3. Maximum product water level was not observed but was set at the detection limit of the analysis.
4. Maximum product water level is set at a value determined in surrogate qualification testing.
5. Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification
testing.
6. The surrogate test results for heptachlor epoxide demonstrated a 98% reduction. These data were used to calculate an upperoccurrence concentration
which would produce a maximum product water level at the MCL.
Woongjin Coway.,Ltd.
658, Yugu-Ri, Yugu Eub, Gongju-Si, Choongchungnam-Do, Korea
Tel.: 82-41-850-7879 Fax.: 82-41-841-7816
37
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
38
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
39
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
40
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTy CARd OR WARRANTy lETTER
ONE yEAR limiTEd WARRANTy
WATER FiRTRATiON dEViCE CHP-04AR/l/U (“PROdUCT”)
Model:
Serial Number:
Customer Name:
Date of Purchase:
(“OWNER”)
What This Warranty Covers:
Limitations and Exclusions:
Commencing with the date of purchase of the
Product and continuing for a period of one year,
if manufacturing defects in the Product cause the
Product to not operate properly for its intended
use, then subject to the exclusions, conditions, and
limitations contained herein, COWAY at its sole
option will repair or replace the Product.
TO THE EXTENT PERMITTED BY APPLICABLE LAW,
COWAY DISCLAIMS ANY OTHER WARRANTY
EXPRESS OR IMPLIED, THAN THAT PROVIDED
FOR HEREIN. THIS WARRANTY IS IN LIEU OF AND
EXCLUDES ALL OTHER WARRANTIES, GUARANTEES,
CONDITIONS AND REPRESENTATIONS, EXPRESS
OR IMPLIED, ORAL OR WRITTEN, STATUTORY OR
OTHERWISE, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED CONDITIONS OR WARRANTIES AS
TO THE MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE OF THE COWAY PRODUCT.
SOME STATES DO NOT ALLOW LIMITATIONS ON
HOW LONG AN IMPLIED WARRANTY LASTS, SO
THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
COWAY DOES NOT AUTHORIZE ANY PERSON
INCLUDING ITS REPRESENTATIVES, TO MAKE ANY
REPRESENTATION OR TO OFFER ANY WARRANTY,
CONDITION OR GUARANTY IN RESPECT OF THE
PRODUCT OTHER THAN THIS WARRANTY. THIS
LIMITED WARRANTY SHALL BE THE OWNER’S
SOLE AND EXCLUSIVE REMEDY AGAINST
COWAY AND COWAY SHALL NOT BE LIABLE FOR
ANY CONSEQUENTIAL, EXEMPLARY, SPECIAL,
INCIDENTAL OR OTHER DAMAGES INCLUDING,
BUT NOT LIMITED TO, LOSS OF PROFITS, AND
LOSS OF USE. INCIDENTAL, CONSEQUENTIAL
AND EXEMPLARY DAMAGES SHALL NOT BE
RECOVERABLE EVEN IF THE REMEDIES OR THE
ACTIONS PROVIDED FOR IN THIS WARRANTY FAIL
OF THEIR ESSENTIAL PURPOSE. SOME STATES DO
NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU. COWAY SHALL NOT BE LIABLE
FOR ANY DAMAGES WHICH ARE BASED UPON
NEGLIGENCE, BREACH OF WARRANTY, STRICT
LIABILITY OR ANY OTHER LEGAL THEORY OF
LIABILITY OTHER THAN THE EXCLUSIVE LIABILITY
SET FORTH IN THIS WARRANTY
Decisions as to the extent of repair or replacement
required will be made solely by COWAY.
The remedy under this Warranty is available only
for that portion of the Product exhibiting defects
at the time of the warranty claim. The replacement
Product as well as any remaining original Product
will be warranted only for the original one year
warranty period. This limited warranty applies
only to Product used for an application specified
by COWAY for the Product and applied in strict
accordance with COWAY published specifications
in effect at the time of application. IF PRODUCT IS
USED FOR OTHER THAN ITS INTENDED PURPOSE,
IT IS SOLD AS IS AND WITHOUT ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
What This Warranty Does Not Cover:
This Warranty warrants that the Product will be
free from manufacturing defects which affect the
ability of the Product to operate for its intended
use; it is not a warranty that the Product will never
require repairs or to undertake responsibilities,
liabilities or obligations other than those
specifically identified in the preceding section.
COWAY is not responsible or liable for personal
injury or property damage of any kind, even if
arising from a breach of this Warranty.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Limitations on Implied Warranties:
Waiver:
Any implied warranty of merchantability or
fitness for a particular purpose or use, shall be
limited to the duration of the foregoing express
written warranty.
COWAY’s failure at any time to enforce or rely
upon any of the terms or conditions stated
herein shall not be construed to be a waiver of
its rights hereunder.
Conditions of Warranty:
Obtaining Warranty Service and OWNER’S
Duties:
COWAY’s continuing liability under this
Warranty is conditioned upon the following :
a) The defect or damage is not caused
by or is the result of : abnormal use or
If the Product fails to operate for its
intended purpose, then notify Coway or its
Representative Agency within 48 hours or
within the next business day after discovery
of any defect in the Product. The OWNER must
give written notice to COWAY no later than
thirty (30) days after a defect is discovered or
should by reasonable diligence have been
discovered. Claims under this Warranty will
require proof of purchase by the OWNER.
conditions; improper storage, unauthorized
modifications or repair; misuse, neglect,
accident, alteration, improper installation or
other acts that are not the fault of Coway or
the manufacturer of the product or that are
not covered by the manufacturer’s warranty;
b) The Product has not been altered, modified
or repaired without prior written approval of
COWAY;
c) The OWNER has notified COWAY in writing
of any failure of the Product covered by this
Warranty within thirty (30) days following
such failure;
d) There has been no misuse, abuse or
negligence with respect to the Product on
the part of the OWNER.
USA
Add :
WOONGJIN COWAY USA, INC.
695 SOUTH VERMONT, STE. 110(SOUTH TOWER) LOS ANGELES, CA 90005, USA
Call Center : (213) 386-9900 / (213) 480-1600
FAX :
(213) 386-3990
42
Download from Www.Somanuals.com. All Manuals Search And Download.
MADE IN KOREA
001
1210107
Download from Www.Somanuals.com. All Manuals Search And Download.
|