Coway Air Cleaner AP 1005AH User Manual

002  
Air Purifier AP-1005AH User's Manual  
1206721  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
Please read this information to prevent property loss and  
ensure your safety.  
Installation safety  
Install this product in a dry  
place.  
It may cause an electric shock  
or a failure.  
Keep away from heater, candle or  
cigarette butts.  
It may cause a fire.  
Warning  
Electricity safety  
Only connect the power  
cord to the voltage rating  
that matches it on the rating  
plate.  
It may cause an  
electric shock or  
a fire.  
Do not connect or work on power  
cable at your disposition. In case  
power cable is broken, make sure  
not to change the cable at discretion  
and contact Service Center.  
Danger  
It may cause an electric  
shock or a fire.  
Do not uses in a place like a  
restaurant in where a lot of  
oil is used or generated.  
It may slow down the  
performance.  
Do not place anything on the product.  
It may cause a failure.  
Be sure to take plug out during  
repair, maintenance, cleaning  
and parts change. Do not  
touch the product with a wet  
hand.  
In case water gets in the power  
part, take power plug out and wait  
until the product dries completely.  
It may cause an  
electric shock  
or a fire.  
Notice  
It may cause an  
electric shock.  
Do not pull out power cable,  
and do not put into and pull  
out power plug continuously.  
It may cause an  
electric shock.  
Do not bend power cable not let  
the cable be pressed by something  
heavy. And do not pull or twist  
power cable.  
It may cause an  
electric shock  
or a fire.  
Keep this product out of the  
direct rays of the sun.  
Do not install on an inclined plane.  
Do not give impact on the product.  
It may cause discoloration and  
decolorization.  
It may cause a breakdown or a failure.  
Clean anything like dust, water  
and etc on the power plug. And  
clean power part regularly.  
do not clean it with volatile matter.  
It may cause an electric shock or a fire.  
03  
04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
Please read this information to prevent property loss and  
ensure your safety.  
Be careful during installation for effective use of the product.  
Keep the product away from wall and  
objects, need more apace than 20cm right  
and left, 30cm ~ 60cm above.  
Air can be dry if the product is used for a long time in an airtight place.  
Operation safety  
Objects near wall and ceiling can be  
contaminated.  
Do not put finger or debris in the  
air intake or blowhole.  
One may not hang or step on the  
product.  
Danger  
Do not poke the product with  
something sharp.  
It may cause an injury.  
It may cause an injury or a failure.  
Keep the product away from lighting  
equipment and direct rays of the sun.  
The product can not be controlled with  
remote controller.  
Do not sprinkle any inflammable  
material as like insecticide or air  
fresheners near the product.  
Be careful not to get you body or  
anything caught in the upper part of  
the product when open front cover.  
Warning  
It may cause a fire of slow down  
of the performance.  
It may cause an injury.  
Install the product away more than 2m from  
electronic goods as like TV.  
There can be electromagnetic interference.  
Change the filter with new filter at  
the time of filter change.  
Wash pre- filter regularly with  
water and dry it thoroughly  
before use.  
Notice  
Be sure that anything does not block  
the product and air-circulation.  
Medium filter, HEPA filter, Ag allergy shield filter,  
Deodorant filter are not recycled by water washing, so  
do not wash them nor put them into water.  
05  
06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES  
Infant mode  
Outstanding air purity capacity  
Run the product with a weak wind to prevent  
infant from feeling cold.  
Used nano silver and catechin treated HEPA  
filter with powerful anti-biotic/anti-mold  
capacity to remove floating minute dust and  
bacteria in the air, and optimized filter system  
to remove pollutant quickly.  
Rhythmical purity system  
Highly improved deodorant capacity  
Applied rhythmical purity system suitable for  
indoor Air-Circulation so that indoor pollutant  
can be removed quickly.  
Smell removal function is more improved  
using deodorant filter which can remove  
not only hazardous gas as like Volatile  
Organic Compounds (VOCs), formaldehyde  
but also food smell or cigarette smell.  
Silent operation at night  
hazardous gas remove test  
VOCs fields (toluene, benzene, xylene, styrene),  
formaldehyde, ammonia, acetaldehyde, acetic acid  
(Other CO mentioned above is not removed.)  
The product is planned to be changed to  
silent operation at night to make silent and  
comfortable surroundings during sleeping.  
Anion generation  
Generate healthy anion to make you feel  
refreshed even in indoor as if you were in the  
woods.  
Wall-mounted type slim design  
Applied slim design which goes well with wall.  
Turbo operation which can remove dust and smell in a short time  
Applied turbo operation system to purify  
indoor space in a short time when dust and  
smell pollution is high.  
Customer centered safety planning  
When the front cover is opened during running,  
all operation will be shut down automatically.  
And planned air intake and blowhole safely to  
prevent any risk of accidents previously.  
Purity level lamp  
Remote controller  
Function to detect purity level of indoor air  
automatically and report to the user on the  
petal purity level lamp and it even has interior  
appearance.  
Applied remote controller for the convenient  
use of the product even in the case the product  
is far away or installed in wall-mounted type.  
07  
08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAMES OF EACH PART  
Front / Side  
Rear  
Handle  
purity level lamp  
Power cord  
Unit hanger  
Air blower  
Operation Part /  
Indication Part  
Air Quality Sensor  
Sensor  
Remote Control  
Power  
Speed  
Mode  
Lamp to display current indoor purity level  
Lamp  
Purity level lamp  
High purity :  
blue  
purity :  
light blue  
Normal :  
light green  
pollution :  
green  
Battery (AAA size)  
09  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAMES OF INTERNAL FILTERS  
OPERATION/INDICATION PART  
Pre- filter  
Medium filter  
Airflow selection switch  
Airflow selection in 5 steps is possible in step 1step 2→  
step 3step 4turbo using airflow selection button.  
(Can be switched to manual operation by pressing airflow  
selection switch during mode operation.)  
HEPA filter  
Ag allergy shield  
filter  
Mode selection switch/lamp  
Deodorant filter  
Mode can be selected in automaticinfantrhythmical  
mode orders by pressing mode selection button.  
Anion  
Lamp selection switch  
Turn purity level lamp on and off.  
Sleeping lamp  
Sleeping lamp is on during sleeping operation.  
Power switch  
Anion lamp  
Anion is generated automatically during operation, and  
anion lamp turns on.  
Remote controller receiving part  
Operation Part /  
Indication Part  
filter case  
Purity level lamp  
Display indoor air purity condition.  
front  
purity level lamp  
(Petal lamp)  
11  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARATIONS  
-
Please remove packing vinyl before installation.  
-
Make sure to use only in indoor and separate plug from outlet when  
the product is not used.  
-
Check front side of filter.  
To install pre- filter, place pre- filter at  
the 6 hooks of filter case correctly with  
FRONT mark front.  
Filter installation  
Filter case hook  
Filter order : pre- filtermedium filterHEPA filterAg allergy shield filterDeodorant filter  
Open front cover and take  
filter case out.  
Pull the lower part of front  
cover, and lift it to open.  
Pull side handle to take out  
filter case from the product.  
Place the lower part of filter case first  
and push the upper part of the case in.  
Install front cover into the  
product and close it.  
Place filter case on the floor, remove packing for each filter and put  
them in the case in reverse according to filter steps.  
Check filters front side during filter installation.  
In case of Ag allergy shield filter, place the filter in its own case with black side  
front and put it in the filter case.  
Remote controller preparations  
Open remote controller pushing  
down the rear part and pushing  
down the battery cover, and  
place AAA size battery setting  
positive and negative pole.  
Close the cover pushing up the  
cover.  
Deodorant filter  
Ag allergy shield filter  
During using of remote controller  
-
-
-
-
If remote controller does not work, check if life-time of battery is over due.  
Use the same size of two AAA batteries to change them.  
Take the batteries out if the remote controller is not used for a long time.  
The life-time of batteries may be differing from the frequency of remote controller.  
How to use remote controller  
-
-
use remote controller facing the receiving part of the product.  
The remote controller can not work if there is any obstacle between the controller  
and the product.  
-
-
Do not impact remote controller.  
Medium filter  
HEPA filter  
Do not keep the controller in a wet place or direct rays of the sun, and near heat of fire.  
13  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO USE  
-
put power plug into the outlet before operation.  
-
At the first use of the product, press power switch to operate the product in  
automatic mode.  
Sleeping operation (Just operated during automatic/infant mode operation)  
When it gets darks during  
automatic/infant mode operation,  
it runs automatically in low  
airflow, Noiseless, low power  
consumption.  
Manual operation  
Turn power switch on, select airflow  
by pressing airflow selection switch.  
step 1step 2step 3step 4turbo  
And it runs in general operation  
when it gets brighten again.  
Sleeping lamp turns on in the light  
of ½light of other lamp.  
Purity level lamp ON/OFF  
Purity level lamp ON/OFF during general  
operation  
Mode selection  
You can turn purity level lamp on and off  
using lamp selection button.  
Turn power switch on, select mode by  
pressing mode selection switch.  
automaticinfantrhythm  
purity level display lamp ON/OFF during sleeping operation  
Purity level lamp turns off when  
lamp selection button is pressed.  
Automatic mode  
Infant mode  
Rhythmical mode  
Press lamp  
Purity level  
selection button.  
lamp turns off.  
Operate efficiently by adjusting  
airflow (step 1, step 2, step 3,  
and step 4) automatically  
according to the indoor  
pollution detected by sensor.  
It is convenient operation mode  
for general users.  
Operate automatically according  
to the indoor pollution as just like  
automatic operation, airflow  
runs at a smaller amount than  
automatic operation to prevent  
an old and feeble person from  
feeling cold by the wind from the  
product.  
To remove dust efficiently even  
the dust at the corner of  
indoor, it operates at 4 steps  
changing airflows.  
When you turn lamp selection  
button again, purity level lamp turns  
Step 1: step 1  
step 4  
Step 2: repetition of step 1  
Step 3: step 1 step 3 step  
step 4  
Step 4: repetition of step 1 ~ 3  
step 2step  
of in the light of  
operation light.  
½of general  
3→  
Press lamp  
selection button.  
Purity level lamp  
turns on in the light  
Purity level lamp ON/OFF is possible  
during power is shut off.  
2→  
of  
½of general  
operation light.  
15  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO USE  
CLEANING METHOD  
-
-
-
Make sure to take power plug out prior to filter cleaning.  
Do not use volatile matter or detergent, etc.  
Air quality sensor  
Do not put the product in water or spray water.  
The product is initially set in standard sensitivity. You can adjust sensor sensitivity as like the  
following methods when humidity is high, when purity level lamp operates more than 2 hours even not  
in the case of severe yellow sand and when purity level lamp keeps green more than 1 hour in the  
case of high indoor pollution.  
Cleaning the air quality sensor (Every 2 Months)  
outlet air inlet  
Clean the air inlet and outlet using a  
vacuum cleaner or soft brush.  
On the condition of operation, press airflow  
selection / mode selection button more  
than 2 seconds at the same time.  
Open the particle sensor cover on the  
right side of the unit (when facing  
the unit). Use a wet  
cotton swab to clean  
and dry the lens, dust  
dust outlet  
Purity level display lamp on the front side  
twinkles in yellowish green color.  
inlet and dust outlet.  
dust inlet  
Cleaning the air intake and outlet  
Clean the air intake and outlet with a soft  
Adjust to desired sensor sensitivity by pressing  
airflow selection button. Sensor sensitivity  
displayed by twinkling mode display lamp.  
brush.  
Be careful not to drop the brush into the unit.  
Insensibility  
Standard  
Sensibility  
Rhythm  
Infant  
Automatic  
Cleaning the negative ion generator (Every 2 Months)  
If press airflow selection/modes election  
button again more than at the same time,  
the product starts working normally and  
sensor sensitivity input.  
If there is no button input for 10 seconds,  
the value input automatically.  
Use a dry cotton swab to remove dust  
on the plate.  
Be careful not to drop the cotton swab into  
the unit.  
17  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING METHOD  
FILTER CLEANING METHOD  
-
-
-
Make sure to take power plug out prior to filter cleaning.  
Pre- filter can be recycled by dust removal or water washing.  
If pre-filter cleaning is not done for a long time, it may cause slow down of  
performance of the product.  
Medium filter, HEPA filter, Ag allergy shield filter, Deodorant filter can not be  
recycled by washing. Washing can damage filters.  
Cleaning the front cover  
Remove the front cover from the unit and  
-
use a dry cloth or soft brush to dust it off.  
Use a wet cloth if necessary but do not use a  
polisher.  
Pre- filter cleaning (Every 2~4 Weeks)  
Lift to separate body pulling the lower  
part of front cover.  
Cleaning the lens on the back of the front cover (Every 2 Months)  
Pull pre- filter handle to take it out.  
Remove the front cover from the unit and  
use a dry cloth, soft brush, or cotton swab  
to dust off the mood light on the back of  
the cover.  
Use a wet cloth if necessary but do not use a  
polisher.  
Remove dust with vacuum cleaner or  
water according to pollution level.  
Cleaning the unit  
Use a dry and soft cloth to clean the unit.  
Use a wet cloth if necessary but do not use a  
polisher.  
Dry well pre- filter to before installing in  
the filter case, and push to the end of the  
product. Install front cover in the product  
again.  
Fix Pre-filter in the filter  
case hook correctly to  
install in the filter case.  
19  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER REPLACEMENT  
Make sure to pull power plug out prior to filter change.  
Replacing the HEPA filter (Every 12 Months)  
Change method  
Open front cover, separate filter case  
out of the product and take HEPA filter  
out of filter case.  
change filters referring to filter preparation section  
in page 13.  
Check front side of HEPA filter, Ag allergy shield  
filter to change filters.  
separate vinyl packing of new filter  
and put HEPA filter in the filter case.  
Assemble filter case  
Just use Coway's genuine product filters.  
in the product and  
close, front cover.  
Replacing the medium filter (Every 4 Months)  
Open front cover and separate filter  
case from the product and take  
medium filter out of filter case.  
Replacing the ag allergy shield filter (Every 6 Months)  
Open front cover, separate filter case out  
of the product and take Ag allergy shield  
filter out of Ag allergy  
shield filter case.  
Remove vinyl packing of the new filter  
and put it into medium filter case.  
Assemble filter case to the product in  
reverse and close  
Remove vinyl packing of new filter, put into  
Ag allergy shield filter case so that black  
non-woven fabric of Ag  
allergy shield comes  
to front side. Assemble  
front cover.  
filter case into the filter  
case in reverse and  
close front cover.  
21  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER REPLACEMENT  
INSTALLATION METHOD  
Make sure to pull power plug out prior to filter cleaning.  
Contact A/S center to install the product on the wall.  
Installation on the wall method  
Replacing the Deodorant filter (Every 12 Months)  
Fitting method  
Open front cover, separate filter case  
out of the product and take Deodorant  
filter out of filter case.  
Install using wall-mounted panel saving some distance  
from wall and ceiling right and left as shown in the picture.  
-
When the product is used on the wall, it may contaminate  
wall or ceiling.  
-
Be careful not to drop front cover and filter case down  
during maintenance or filter change.  
- Do not pull power cord.  
Make sure the product is installed strongly on the screw of wall-  
mounted panel.  
Remove vinyl packing of new filter, Put  
Deodorant filter into the filter case.  
Assemble filter case  
wall-mounting parts  
Hanger (1 ea)  
into the product in  
reverse of separation,  
and closefront cover.  
screw (6 ea)  
anchor (6 ea)  
rubber foot (2 ea)  
Filter Orders  
Pre- medium HEPA Ag allergy shield Deodorant  
Determine the place on which the  
product is going to be installed.  
Make a hole to install  
hanger using a nail  
and put an anchor in.  
Place hanger on it  
Cleaning and replacement schedule  
Replacement  
Cleaning  
Filters  
Pre-  
and fix it on the wall  
using screw.  
Every 2~4 Weeks  
Cleaning  
Every 4 Months  
Every 12 Months  
Every 6 Months  
Every12 Months  
Replacement  
Replacement  
Replacement  
Replacement  
Medium  
Place rubber foot on the 2 ea of round  
projection on the lower part of the  
back side of the product.  
HEPA  
Ag Allergy Shield  
Deodorant  
based on 24 hours/1 day automatic operation.  
23  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION METHOD  
BEFORE ASKING A/S  
Installation on the wall method  
Please check the followings before request for A/S.  
Please check out the following information before contacting Customer  
Service. The unit might not operate properly due to a lack of knowledge  
about the unit. If the problem still remains despite referring to this guide, then  
please call the customer service center.  
Separate base by pulling out screw  
on the lower part of the back side.  
Symptom  
Check  
Remedy  
Is power plug connected?  
Voltage rating that matches it  
on the rating plate.  
Is display parts are all off?  
Press operation/stop button  
and select desired function.  
No wind blows  
out.  
Check if it is not a power failure.  
Use the product after  
power is on.  
Install the product in the hanger.  
Make sure to check after  
Make sure that hanger fits in the  
hanger rack on the back side of the  
product completely.  
installation!  
Is in manual operation?  
Is the room dark?  
Set the product at the  
desired operation mode.  
No wind change  
in automatic/  
infant / rhythmical  
operation.  
Wind fixed to the latest  
during night silent operation.  
Is there dust on the nearby sensor  
lens?  
Clean dust nearby  
sensor lens.  
Page 18  
Color of purity  
level lamp is  
always same.  
Is dust purity level keeps showing  
high?  
Adjust dust sensor to  
insensitivity or standard.  
Page 17  
Page 17  
Is dust purity level keeps showing  
high?  
Adjust dust sensor to  
sensibility or standard.  
( O )  
Wind volume is  
very weak. It  
smells from  
ventilator.  
Is filter cleaning and change time  
overdue?  
Install correctly. Check  
to clean or change the  
filters.  
Page 20~23  
Hanger  
Check the batteries.  
Changer the batteries.  
Page 14  
Page 14  
Check if the batteries are fitted in  
correctly (positive, negative)?  
Check positive and  
negative pole of the  
batteries.  
Remote controller  
does not work.  
( X )  
Does the room light twinkles?  
Change fluorescent light or  
move the product.  
Is there any electronic goods near  
the product?  
Keep the product away from  
electronic goods more than 2 m.  
Check installation and install filter and front cover on the product.  
25  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE ASKING A/S  
Warranty Information  
Symptom  
Remedy  
Check  
& Specifications  
Is filter cleaning and change time  
overdue?  
Check filter cleaning and  
change time and filter to clean  
or change filters.  
Smells from  
blowhole.  
Purity display  
part twinkles.  
Request for A/S and ask for it.  
Please fill in the blanks  
and save this in order  
to request service.  
Other functional  
matter happens  
Check the conditions of the problem and take power plug  
out to request for A/S and ask for it.  
Customer Information  
Warranty Period  
1 year  
Product Name  
Air Purifier  
Model  
AP-1005AH  
SER. No.  
Purchase Date  
Warranty Period  
Address  
Day  
Day  
Month  
Month  
Year  
Year  
Until  
Month  
Year  
TEL.  
Customer's Name  
MOBILE.  
Specifications  
Power Supply  
Voltage rating that matches it on the rating plate.  
Power consumption  
47W  
HEPA Filter Type  
Automatic power-off  
300ft2  
Dust Collection Method  
Safety Method  
Room Size  
Maximum Volume of Air  
Size  
5.8/min  
(W)544X(D)181X(H)510mm  
8.8 kg  
Weight  
Without prior notice the unit could be changed to improve its performance.  
27  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Guarantee  
Parts and components shall be replaced free of charge within the guarantee period if  
the defects occur due to manufacturing defects in normal operation.  
Contact us in case of breakdown.  
In the following cases, repair work shall be charged even within the guarantee period.  
Breakdown caused by careless operation or unreasonable repair and renovation.  
Breakdown caused by nonperformance of the instructions specified in the manual.  
Even after the expiration of guarantee period, it is possible to apply for charged repair.  
Present this Letter of Guarantee whenever repair is needed.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
This Letter of Guarantee is valid only in domestic where you buy this product.  
Keep this Guarantee carefully as it is not re-issued.  
Please contact our customer's service center in case you are not satisfied with our A/S service.  
Nationwide A/S Call :  
Customer counseling Center Call:  
Fax :  
In case any other filters or parts which are not genuine  
products of Coway are used, Coway is not responsible for  
any problems related to water quality.  
Coway Co., Ltd.  
658 Yoogoo-Ri, Yoogoo-Eub, Gongju-Si, Choongnam Province, Korea  
29  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Craftsman Trimmer 10479211 User Manual
Cuisinart Toaster CPT 140RC User Manual
Cypress Computer Drive CY7C67200 User Manual
Dacor Microwave Oven MMDV30 User Manual
Dual CD Player MXD45 User Manual
Electro Voice Microphone 633 User Manual
First Alert Home Security System FA848C User Manual
Fisher Price Air Conditioner K4565 User Manual
Gefen Network Card GTV HDMI13 141 User Manual
GE Vacuum Cleaner 106575 User Manual