ROADWAY
400-1000W
HMC HIGH MAST
MH/HPS
LARGE AREA LUMINAIRE
2 3/8"
[61mm]
O.D. Pipe
19 3/8"
[492mm]
23 3/4"
[503mm]
4 3/8"
[111mm]
28" [711mm]
Horizontal Lamp Configuration
STREETWORKS™
HOUSING
ORDERING INFORMATION
Die-cast aluminum housing and
cover. Standard bronze polyester
powder coat finish. Other finish
colors available. Consult your
Streetworks Representative.
SAMPLE NUMBER: HMC40SC23E
PRODUCT
FAMILY
HMC
LAMP
LAMP TYPE 1
S=HPS
M=MH
BALLAST TYPE 1
C=CWI
VOLTAGE 1
OPTICAL
PACKAGE
1=Type I
2=Type II
3=Type III
4=Type IV
OPTIONS +
ACCESSORIES
(See Below)
DISTRIBUTION
A=SCO
D=MCO
E=MSCO
L=LMCO
WATTAGE
40=400W
91=1000W
2=120V
0=208V
4=240V
7=277V
8=480V
9=347V
W=Multi-Tap wired 120V
N=Multi-Tap wired 277V
V=Multi-Tap wired 240V
K=10KV CWA 2
M=Mag. Reg. 3
W=CWA
MOUNTING
Clamp type slipfitter for 2 3/8"
O.D. pipe.
OPTICS
Anodized spun aluminum outer
reflector housing. Light pattern
can be oriented by rotating optical
assembly (360°). A degree indicator
is provided to identify the aiming
position.
OPTIONS + ACCESSORIES [ Must be listed in the order shown and separated by a dash]
OPTIONS (add as suffix)
ACCESSORIES (order separately)
OA/RA1016=105-285V Photocontrol
OA/RA1027=480V Photocontrol
1=Single Fuse, Internally Mounted (120, 277V)
2=Double Fuse, Internally Mounted (208, 240 & 480V)
3=Four-Stage Air Filter 4
REFLECTOR
Inner hydroformed and anodized
reflector.
OA1153=External Cutoff Shield (.90 EPA)
4=Photocontrol Receptacle
AP=Grey
DOOR
B=Plastic Two Position Terminal Block
F=Flat Glass
Die-cast aluminum door with
tempered convex glass lens and
silicone rubber gasket.
M=MOV Lighting Surge Protector 5
OPTIONAL COLORS [ Standard color is bronze, other finish colors available. Consult your Cooper Lighting representative]
AP
Grey
EPA:
Effective Projective Area: 1.46
SHIPPING DATA
Approximate Net Weight:
68 lbs. (30 kgs.)
NOTE: 1 Refer to technical section for lamp/ballast/voltage compatibility. 2 1000W HPS only. 3 Not available on 1000W units. 4 Four-Stage air filter prevents entrance of dust particles .00025mm and larger. 5 MOV option is not
available for any system requiring a three position terminal block (Example—120/240 incoming line). In order for MOV option to function center terminal of three position terminal block must be connected to “Earth” ground.
128 STREETWORKS Outdoor Lighting Solutions
Download from Www.Somanuals.com. All Manuals Search And Download.