Cooper Lighting Indoor Furnishings Vision Flood User Manual

TM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FLOODLIGHTING FUNDAMENTALS  
- Inverse Square Cosine Law  
Footcandle levels are ultimately dependent upon the projected distance, aiming angle, and luminous intensity of a lamp/reflector combination.  
A cursory understanding of the equation which relates these variables provides insights to proper design technique and distribution selection.  
INVERSE SQUARE COSINE LAW  
E=I cos (x)/D2 -or-  
Illuminance (Footcandles, fc) = Luminous Intensity (Candelas, Cd) * cos (incident angle X) / Distance2  
Holding other variables constant, as the projected distance increases from the luminaire to the surface being illuminated, a greater amount  
of luminous intensity (I, Candela) is required to sustain an equal illuminance (E, Footcandle) level.  
2
E D  
2
E D  
I=  
I=  
E=5 fc  
COS (x)  
COS (x)  
X=30°  
2
5 fc (20')  
2
E=5 fc  
5 fc (10')  
=
2,310 candela  
=
577 candela  
X=30°  
COS (30°)  
COS (30°)  
30°  
30°  
Holding incident angle X constant at 30Ëš while increasing the projected distance D from 10' to 20' requires an increase in candela from  
577 to 2310 respectively to sustain an equal 5 footcandles (fc) of illumination at the target point.  
The incident angle as measured from a luminaire’s directed intensity to the target surface normal also plays a significant role in determining  
illuminance values. Holding other variables constant as the incident angle from the target surface to the projected aiming line increases, so does  
the amount of luminous intensity (I, Candela) required to sustain an equal illuminance value.  
2
2
E D  
E D  
E=fc  
I=  
I=  
X=45°  
COS (x)  
COS (x)  
E=5 fc  
X=30°  
2
2
5 fc (10')  
5 fc (10')  
=
577 candela  
=
707 candela  
COS (30°)  
COS (45°)  
45°  
30°  
Holding projected distance D constant at 10' while increasing incident angle X from 30Ëš to 45Ëš requires an increase in candela from  
577 to 707 respectively to sustain an equal 5 footcandles (fc) of illumination at the target point.  
3
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FLOODLIGHTING TERMINOLOGY  
- Floodlighting Terminology  
- NEMA [IES] Classifications  
FLOODLIGHTING TERMINOLOGY  
Ever wonder how NEMA (H x V) Classifications are derived, or how they relate  
to the performance and design application of a floodlighting distribution?  
How about beam and field angles, and maximum candela values?  
FIG. 1  
- Maximum Candela is defined as the maximum candela value emitted  
from the luminaire in any given direction.  
90°  
80°  
90°  
80°  
- Beam angle is defined as the included angle between points of 50%  
of Maximum Candela.  
Field Angle  
70°  
60°  
70°  
60°  
0
0
0
- Field Angle is defined as the included angle between points of 10%  
of Maximum Candela.  
50°  
45°  
50°  
45°  
0
Beam Angle  
As an example, a distribution with a 50,000 Cd maximum candela value  
as shown in the intensity distribution graph to the right (FIG. 1) would have a  
Beam Angle defined by the included angle of 25,000 Cd values, and a Field  
Angle defined by the included angle of 5,000 Cd values.  
0
40°  
40°  
0
00  
00  
30°  
30°  
EXAMPLE  
20°  
20°  
000  
0°  
10°  
10°  
Max Candela = 50,000 Cd  
Candela Value defining Beam Angle = (50% * 50,000 Cd) = 25,000 Cd  
Candela Value defining Field Angle = (10% * 50,000 Cd) = 5,000 Cd  
Beam Angle = 90°  
Field Angle = 120°  
NEMA [IES] CLASSIFICATIONS  
NEMA classifications are extrapolated from the table below and are determined by a distribution’s Field Angle. This relative classification is used  
to describe the general shape and application of a distribution. NEMA classifications are used to classify both the horizontal and vertical  
components of a floodlight distribution.  
The example distribution in FIG. 1 above would have a NEMA Classification of 6 as the 120° Field Angle falls between the 100-130° range.  
NEMA Beam  
Classification  
Field Angle  
Range  
Description +  
Setback  
1
2
3
4
5
6
7
10-18°  
Narrowest Beam, Long Setback  
Narrow Beam, Long Setback  
Narrow Beam, Long Setback  
Medium Beam, Medium Setback  
Medium Beam, Medium Setback  
Wide Beam, Shorter Setback  
Widest Beam, Short Setback  
18-29°  
29-46°  
46-70°  
70-100°  
100-130°  
130°-Greater  
4
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VISION Flood offers a host of beam control options that limit  
unwanted stray light and control direct viewing  
of the lamp source.  
SPILL + GLARE CONTROL  
- Internal Louvers  
- External Grid Louvers  
- Top Visor  
- 4 Sided Shield  
- Barn Doors  
- Rectangular Beam Patterns  
Limiting the amount of stray light which falls beyond the boundaries of the intended target is not only good design practice, but is increasingly  
a mandate of local and state adopted lighting ordinances. The VISION Flood series offers a family of beam control options to limit unwanted stray  
light and control direct viewing of the lamp, a common source of discomfort and disability glare.  
INTERNAL LOUVERS  
Standard on Narrow Spot and Narrow Flood  
distributions, integral ring louver controls lamp  
glare while eliminating spill light outside the  
main beam.  
Without Internal Louvers  
With Internal Louvers  
EXTERNAL GRID LOUVERS  
Designed to control lamp glare and spill light  
while maintaining beam efficiency. Useful when  
aiming direction or intended target lies in close  
proximity to pedestrian and/or motor vehicle  
activity. Mounts to accessory channel in  
doorframe. Compatible with all distributions.  
Available on VFM only.  
With External Louvers  
Without External Louvers  
5
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOP VISOR  
Controls excess spill and glare on top portion  
of distribution. Especially useful in uplighting  
applications to limit light travel above an  
intended wall surface or sign. Mounts to  
accessory channel in doorframe. Compatible  
with all distributions.  
With Top Visor  
Without Top Visor  
4-SIDED SHIELD  
Controls lamp glare and spill light in all  
directions. Useful when aiming direction or  
intended target lies in close proximity to  
pedestrian and/or motor vehicle activity.  
Mounts to accessory channel in doorframe.  
Compatible with all distributions. Available on  
VFM only.  
With 4-Sided Shield  
Without 4-Sided Shield  
BARN DOORS  
Four (4) independently mounted and adjustable  
doors control cutoff angles in all directions,  
allowing custom distribution control. Compatible  
with all distributions.  
Without Barn Doors  
With Barn Doors  
RECTANGULAR BEAM PATTERNS  
Structures, signs, and other various objects which  
dominate our visual landscape are largely defined  
by straight lines and planar surfaces. Lighting  
these objects with rectangular distributions  
eliminates excess spill light while maintaining  
optimal uniformity.  
Typical Round Beam Patterns  
Rectangular Beam Patterns  
Typical round patterns create shadows in  
corners, requiring closer fixture  
Rectangular beams produce more  
uniform coverage, resulting in reduced  
fixture counts and less stray light  
spilling beyond the intended target.  
spacings. Uniformity is compromised.  
6
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN GUIDE  
- Illumination Recommendations  
- Beam Pattern Information  
ILLUMINATION RECOMMENDATIONS  
Effective floodlighting design is a complex and subjective task. Results are heavily dependent upon surrounding light levels, surface finish of the  
intended target, spectral color distribution of the lamp source, mounting location allowances, and viewers perceptions.  
The following table lists IESNA (Illuminating Engineering Society of North America) recommended illuminance levels for the floodlighting of  
buildings and monuments.  
Area  
Description  
Target Surface  
Finish  
Average Target  
Illuminance  
Bright Surroundings  
Bright Surroundings  
Bright Surroundings  
Dark Surroundings  
Dark Surroundings  
Dark Surroundings  
Dark Surroundings  
Light Surfaces  
5 fc  
7 fc  
10 fc  
2 fc  
3 fc  
4 fc  
5 fc  
Medium Light Surfaces  
Dark Surfaces  
Light Surfaces  
Medium Light Surfaces  
Medium Dark Surfaces  
Dark Surfaces  
Cooper Lighting Application Engineers are available to assist in providing design layouts, aiming diagrams, and illuminance plots for your next  
floodlighting project. Consult your INVUE Lighting Systems Representative for more information.  
BEAM PATTERN INFORMATION  
NEMA  
IES  
Type  
Beam  
(50% Max. Candela)  
in Degrees  
Field Angle  
(10% Max. Candela)  
in Degrees  
Maximum  
Candela  
Value  
Lamp  
Wattage  
Lamp  
Type  
Beam  
Pattern  
Total  
Efficiency  
1
175W MH  
ED-17  
Narrow Spot  
Narrow Flood  
Medium Flood  
Wide Flood  
Vertical Flood  
Horizontal Spot  
1 H x 3 V  
3 H x 3 V  
5 H x 3 V  
7 H x 6 V  
7 H x 6 V  
6 H x 6 V  
7 H x 15 V  
16 H x 23 V  
52 H x 18 V  
70 H x 55 V  
98 H x 58 V  
80 H x 27 V  
17 H x 33 V  
30 H x 45 V  
74 H x 41 V  
132 H x 103 V  
147 H x 130 V  
111 H x 120 V  
102,434  
53,892  
25,698  
8,346  
5,420  
10,694  
60%  
71%  
84%  
84%  
71%  
83%  
2
400W MH  
BT-37  
Narrow Spot  
Narrow Flood  
Medium Flood  
Wide Flood  
Vertical Flood  
Horizontal Spot  
1 H x 2 V  
2 H x 3 V  
4 H x 4 V  
7 H x 6 V  
7 H x 7 V  
5 H x 5 V  
8 H x 16 V  
14 H x 27 V  
23 H x 36 V  
48 H x 49 V  
137 H x 101 V  
145 H x 139 V  
94 H x 90 V  
304,593  
162,701  
92,191  
20,734  
14,761  
34,463  
41%  
50%  
81%  
81%  
74%  
61%  
12 H x 19 V  
22 H x 23 V  
86 H x 58 V  
106 H x 57 V  
86 H x 15 V  
3
1000W MH BT-37  
Narrow Spot  
Narrow Flood  
Medium Flood  
Wide Flood  
Vertical Flood  
Horizontal Spot  
1 H x 4 V  
2 H x 4 V  
4 H x 4 V  
7 H x 6 V  
7 H x 7 V  
6 H x 5 V  
5 H x 16 V  
13 H x 48 V  
29 H x 55 V  
53 H x 68 V  
139 H x 116 V  
152 H x 135 V  
105 H x 96 V  
633,201  
279,879  
197,476  
52,625  
42,981  
51%  
53%  
78%  
83%  
76%  
64%  
14 H x 27 V  
23 H x 33 V  
85 H x 74 V  
111 H x 55 V  
85 H x 16 V  
99,290  
4
150W HPS  
400W HPS  
ED-17  
ED-18  
Narrow Spot  
Narrow Flood  
Medium Flood  
Wide Flood  
Vertical Flood  
Horizontal Spot  
1 H x 4 V  
3 H x 4 V  
5 H x 4 V  
7 H x 6 V  
7 H x 6 V  
5 H x 6 V  
9 H x 23 V  
21 H x 31 V  
49 H x 27 V  
8 x 69 V  
99 H x 55 V  
77 H x 14 V  
17 H x 46 V  
31 H x 57 V  
77 H x 54 V  
136 H x 109 V  
145 H x 126 V  
95 H x 112 V  
74,261  
41,007  
23,522  
7,567  
6,331  
18,237  
61%  
70%  
81%  
79%  
69%  
84%  
5
Narrow Spot  
Narrow Flood  
Medium Flood  
Wide Flood  
Vertical Flood  
Horizontal Spot  
1 H x 4 V  
2 H x 4 V  
4 H x 5 V  
7 H x 6 V  
7 H x 7 V  
6 H x 5 V  
6 H x 20 V  
13 H x 47 V  
27 H x 52 V  
54 H x 71 V  
140 H x 117 V  
145 H x 137 V  
102 H x 100 V  
260,454  
112,314  
86,573  
21,630  
20,686  
44,433  
48%  
44%  
78%  
80%  
75%  
62%  
15 H x 27 V  
23 H x 33 V  
88 H x 80 V  
102 H x 60 V  
81 H x 15 V  
1 If using a 100W MH lamp, apply a 0.629 scaling factor to the 175W MH maximum candela values.  
2 If using a 250W MH lamp, apply a 0.569 scaling factor to the 400W MH maximum candela values.  
3 If using a 750W MH lamp, apply a 0.745 scaling factor to the 1000W MH maximum candela values.  
4 If using a 100W HPS lamp, apply a 0.594 scaling factor to the 150W HPS maximum candela values.  
5 If using a 250W HPS lamp, apply a 0.55 scaling factor to the 400W HPS maximum candela values.  
7
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COLOR CAPABILITIES  
Infusing color to a visual landscape elicits attention,  
emotion, and intrigue.  
COLOR CAPABILITIES  
VISION Flood can be specified with one of four (4) standard color gels: Deep Green, Bright Blue, Red or Warm Orange. Dichoric glass filter options  
and custom colors are also available. Consult your INVUE Lighting Systems Representative for more information.  
WITH COLOR FILTER  
ADAPTER  
METAL HALIDE  
DEEP GREEN FILTER  
HIGH PRESSURE SODIUM  
DEEP GREEN FILTER  
METAL HALIDE  
BRIGHT BLUE FILTER  
HIGH PRESSURE SODIUM  
BRIGHT BLUE FILTER  
METAL HALIDE  
RED FILTER  
HIGH PRESSURE SODIUM  
RED FILTER  
METAL HALIDE  
WARM ORANGE FILTER  
HIGH PRESSURE SODIUM  
WARM ORANGE FILTER  
NOTE: Color representations are for comparative purposes only, and do not imply achieved color in application which is dependent upon lamp  
source, optic, and target surface properties.  
8
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
With six (6) uniquely shaped optical distributions, the VISION Flood  
provides targeted lighting solutions for facade, sign, landscape,  
architectural highlighting, and more.  
OPTICAL CONFIGURATIONS  
All optical systems are fully interchangeable, featuring toolless release fasteners and wire connectors.  
NARROW SPOT [NS]  
The Narrow Spot distribution creates a  
narrow column of light, free from spill light  
8°  
outside the main beam. Ideal for  
illuminating columns, small architectural  
16°  
details, tall trees, high mount signage, and  
flagpoles. Generally used with farther  
setbacks.  
NARROW FLOOD [NF]  
Designed for applications where a tight,  
symmetrical beam is required, often with  
12°  
farther setbacks. Ideal for longer distance  
19°  
facade highlighting, flag lighting, and high  
mount signage.  
MEDIUM FLOOD [MF]  
Designed for applications requiring a wider,  
rectangular pattern of uniform illumination.  
22°  
Ideal for medium setback floodlighting of  
23°  
facades, signage, general landscape, and  
indirect canopy lighting.  
11  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPTICAL CONFIGURATIONS  
WIDE FLOOD [WF]  
Designed for applications requiring a wide  
rectangular pattern of uniform illumination.  
Generally used with shorter setbacks to  
floodlight large facades, signage, and broad  
leaf foliage. Also effective in pole mount  
applications for general area illumination.  
86°  
58°  
VERTICAL FLOOD [VF]  
Designed to illuminate tall facades and  
signage in limited setback applications.  
In pole mount applications, the Vertical  
Flood produces a broad forward throw  
distribution ideal for area lighting.  
57°  
106°  
HORIZONTAL SPOT [HS]  
The Horizontal Spot optic creates a  
concentrated pattern that is wide  
86°  
horizontally, yet tight vertically. Ideal for  
lighting wide ground mount signage, and  
highlighting wide building-mounted objects  
and signage. Also ideal in wall mount and  
short setback applications to graze a wall  
surface, creating depth and contrast that  
accentuates architectural details.  
15°  
VISION Flood Premium 95% Reflective Surface  
Competitor's Standard 86% Reflective Surface  
PREMIUM MATERIALS  
A commitment to using premium  
95% reflective aluminum sheet for  
all reflective faces allows for efficiency  
gains of up to 10%.  
100%  
95%  
86%  
PREMIUM MATERIAL  
STANDARD MATERIAL  
Standard material reflects a lower intensity  
of light.  
Premium material reflects a higher intensity  
of light in a more controllable fashion.  
12  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VISION Flood luminaires provide unsurpassed levels of protection  
against entry of airborne contaminants. With a certified IP65 fixture  
rating, dust, insects, and moisture simply have no chance of  
penetrating the fixture’s outer enclosure.  
FIXTURE SEALING  
- IP Rating  
IP RATING  
"IP" stands for Ingress Protection and is a rating system established  
I
P
6
5
by the European organization IEC, International Electrotechnical  
Commission. Over 50 countries strong, this organization publishes  
international standards for electrical products and other related  
technologies. The two numbers proceeding the "IP" individually callout  
the fixture’s protection ratings against airborne particulates and moisture  
respectively.  
Ingress  
Protection  
Complete  
protection  
against  
dust entry  
No moisture  
within fixture  
after a constant  
100L/min. pressure  
jet spay from all  
practical directions  
13  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LAMP SOURCE OPTIONS  
- Metal Halide | Pulse Start Metal Halide  
- High Pressure Sodium  
LAMP OPTIONS  
VISION Flood optical systems are offered with a variety of high efficiency lamp sources.  
METAL HALIDE/  
HIGH PRESSURE SODIUM  
Produces an yellowish-orange light with  
high efficacy (lumens per watt) and long  
life.  
AVAILABLE LAMP OPTIONS PER  
HOUSING SIZE  
PULSE START METAL HALIDE  
Produces a whitish-blue light, excellent  
color rendition up to 92 CRI, and high  
efficacy (lumens per watt).  
VFS  
VFM  
Metal Halide  
50, 70, 100, 175W 175, 250, 400, 1000W  
250, 320, 350, 400, 750W  
Pulse Start Metal Halide  
High Pressure Sodium  
APPLICATION: HPS sources add a  
richness and warmth that best  
complements brick, wood, and dark  
colored masonry or stone surfaces.  
50, 70, 100, 150W 150, 250, 400W  
APPLICATION: Generally, Metal Halide  
sources best compliment concrete  
surfaces, light colored masonry, foliage,  
and bright colored objects and surfaces.  
AIMING VERSATILITY  
- Taper Lock Knuckle  
- Competitor’s Tooth Lock Knuckle  
Limited  
Infinite Aiming  
Incremental  
Aiming  
20°  
15°  
10°  
5°  
TAPER-LOCK KNUCKLE  
COMPETITOR’S TOOTH LOCK KNUCKLE  
The taper-lock knuckle featured on all VISION Flood luminaires is a  
powerful differentiator that insures ultimate aiming flexibility, and  
rock solid strength.  
Competitors tooth lock knuckle designs notably limit the vertical  
aiming adjustment of the luminaire, making it more difficult to  
achieve desired uniformity ratios and cutoff control. Typical tooth  
lock designs are limited to adjustments in increments of 5 to 7.5°.  
VISION Flood’s taper-lock mechanism allows for infinite vertical aiming  
adjustment within the fixture’s aiming range. This feature empowers  
Designers with ultimate aiming discretion, and allows installers or end  
users the ability to visually optimize the distribution once installed to  
deliver exacting performance.  
14  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOUSING  
One-piece, die-cast aluminum housing maintains a nominal .125" thickness to endure the  
toughest environments while maintaining precise tolerance control.  
DOOR  
Die-cast aluminum door maintains a nominal .125" thickness and features concealed  
hinging to the housing. Door is secured with four (4) tamper resistant recessed stainless  
steel allen head fasteners. Door frame features an integral accessory channel for the  
mounting of optional light control accessories. Doorframe seals to housing with a  
continuous extruded silicone gasket. Lens is impact resistant .180" thick tempered clear  
flat glass, sealed to the door with a one-piece silicone gasket.  
PRODUCT SPECIFICATIONS  
- Features + Benefits  
OPTICAL ASSEMBLY  
Choice of six (6) high efficiency optical systems constructed of premium 95% reflective  
anodized aluminum sheet, or bright specular anodized polished spun aluminum. Available  
distributions include Narrow Spot, Narrow Flood, Medium Flood, Wide Flood, Horizontal  
Spot, and Vertical Flood. All reflector modules feature toolless removal, quick disconnect  
wire connections, and are field interchangeable. Medium housing (VFM) optics feature  
mogul-base lampholders while small housing (VFS) optics feature medium-base  
lampholders.  
KNUCKLE  
Heavy-duty die-cast aluminum knuckle utilizes a taper-lock adjustment mechanism for  
both solid engagement and infinite aiming adjustment. Knuckle adjustment is made via  
one (1) captive stainless steel allen head fastener consistent with doorframe fasteners.  
Tested to sustain 3G of vibration without loosing aiming position. VFS knuckle features a  
3/4" NPT nipple on bottom surface for rigid attachment to available mounting  
accessories. Optional slipfitter mount available for VFS. VFM lower knuckle slip-fits over  
a standard 2" pipe size (2 3/8" O.D.) tenon.  
ELECTRICAL COMPONENTS  
High Power Factor (HPF) ballast components are strategically located and heat sunk to  
the housing for cooler operation and longer life. The VFS housing is rated for 40°C  
(104°F) ambient environments.  
17  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FINISH  
Housing and arm finished in a 5 stage  
premium TGIC polyester powder coat paint,  
2.5 mil nominal thickness for superior  
protection against fade and wear. Standard  
colors include black, bronze, grey, white, dark  
platinum, and graphite metallic. RAL and  
custom color matches available. Consult your  
INVUE Lighting Systems Representative for  
more information.  
Certifications  
IP65 Rated U.L. 1598 Listed 3G Vibration Rated ISO 9001  
CSA Listed  
40°C Ambient [VFS]  
25°C Ambient [VFM]  
DIMENSIONS  
Vision Flood Small [VFS]  
Vision Flood Medium [VFM]  
10"  
[254 mm]  
16 1/2"  
[419 mm]  
X
7 1/2"  
[191 mm]  
X=2 15/16"  
[75 mm]  
14" [356 mm]  
7 11/16"  
[196 mm]  
23" [584 mm]  
11 13/64" [284 mm]  
18  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VFS MOUNTING OPTIONS + SPECIFICATIONS  
- Specifications + Dimensions [VFS Standard Mount]  
3/4" [20 mm] Dia.  
3/4" [20 mm] Dia.  
5"  
[127 mm]  
4 1/2"  
[115 mm]  
190°  
190°  
4" [102 mm]  
4 1/4"  
[108 mm]  
VFS STANDARD MOUNT  
JUNCTION BOX [JB]  
SLIPFITTER [SF]  
The VFS knuckle features a 3/4" NPT threaded  
nipple on its bottom surface for direct mounting to  
the following accessories: Junction Box (JB),  
Slipfitter (SF), Stanchion Mount (SM), Twin Arm  
Mount (TMA), Wall Mount Arm (WMA), Wall Mount  
(WM), and Post Mount Extensions (PM1, PM2).  
U.L. and CSA listed for wet locations, the Vision  
J-Box is supplied with a 3/4" clearance hole on the  
top surface and two (2) 3/4" NPT openings on the  
bottom surface. An optional drilling consisting of  
one (1) 1/2" NPT opening on the bottom surface  
can be specified.  
Die-cast aluminum slipfitter features a 3/4" NPT  
entry point on top surface to mate to standard VFS  
knuckle. Allows fixture assembly to be mounted to  
standard 2" pipe size (2 3/8" O.D.) tenons and tenon  
equipped accessories.  
3/4" [20 mm] Dia.  
5/16" [8 mm] Dia.  
15" [381 mm]  
24" [610 mm]  
18"  
[457 mm]  
6 1/2"  
[165 mm] Sq.  
3/4" [20 mm] Dia.  
5/16" [8 mm]  
Dia.  
3/4" [20 mm] Dia.  
190°  
190°  
190°  
6" [152 mm]  
Sq. Bolt Pattern  
STANCHION MOUNT [SM]  
TWIN ARM MOUNT [TMA]  
WALL MOUNT ARM [WMA]  
Used to mount fixture above grade to solid surface,  
or partially buried when secured to concrete pad.  
Cast aluminum housing and mounting plate is 18"  
tall and is supplied with a single 3/4" clearance  
hole entry point.  
Soft form extruded aluminum arm is 24" in length  
and features two (2) 3/4" clearance holes for twin  
fixture mount. Other lengths and drilling patterns  
available upon request. Twin arm base slip fits over  
standard 2" pipe size (2 3/8" O.D.) tenon. End caps  
are removable for wiring access. Useful in ground  
mount and pole mount applications.  
Extruded aluminum arm with cast mounting plate is  
15" in length and is supplied with a 3/4" clearance  
hole entry point. Also useful as an arm extension  
off square area light poles.  
6"  
[152mm]  
Diameter  
5"  
[127 mm]  
190°  
190°  
4" [102 mm]  
WALL MOUNT [WM]  
POST MOUNT EXTENSION [PM1/PM2]  
Cast aluminum assembly slip fits over standard 2"  
pipe size (2 3/8" O.D.) tenons, and allows for single  
(PM1), or double (PM2) mount configurations.  
Assembly allows for 360° of fixture rotation.  
Top cap provides splice access. Useful for single or  
twin, pole mounted downward aiming applications.  
Cast aluminum mounting plate adapts around  
4" square or octagonal J-box by others. Additional  
stud mounting is required beyond J-box  
attachment. Consists of mounting bracket and  
cast aluminum splice access cover providing a  
clean transition to the wall surface. Hanger  
mount integral to mounting plate allows for  
ease of installation.  
19  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VFS|VFM MOUNTING OPTIONS + SPECIFICATIONS  
- Specifications + Dimensions [Slipfitter Mount]  
5/16" Dia.  
[8 mm]  
4"  
[102 mm]  
190°  
6 1/2"  
[166 mm] Sq.  
5" [127 mm]  
When coupled with the available slipfitter (SF), the  
VFS can be mounted to the following accessories:  
Surface Mount Tenon (SMT), Stanchion Mount  
Tenon (ST), Twin Mount Arm Tenon (TMT), and Wall  
Mount Arm Tenon (WMT).  
The VFM lower knuckle slip-fits over a standard 2"  
pipe size (2 3/8" O.D.) tenon. VFM can be mounted  
to the following accessories: Surface Mount Tenon  
(SMT), Stanchion Mount Tenon (ST), Twin Mount  
Arm Tenon (TMT), and Wall Mount Arm Tenon  
(WMT).  
SURFACE MOUNT TENON [SMT]  
For above-grade surface mount placement, the  
SMT is supplied with a 4" tall standard 2" pipe size  
(2 3/8" O.D.) tenon.  
2 3/8" [60 mm]  
4" [102mm]  
4"  
24" [610 mm]  
[102 mm]  
4"  
[102 mm]  
18"  
[457 mm]  
15"  
[381 mm]  
5/16"  
[8 mm]  
Dia.  
3/4" [20 mm] Dia.  
5"  
[127 mm]  
Sq. Bolt Pattern  
190°  
190°  
190°  
6" [152 mm]  
Sq. Bolt Pattern  
STANCHION MOUNT TENON [ST]  
Used to mount fixture above grade to solid surface,  
or partially buried when secured to concrete pad.  
Cast aluminum housing and mounting plate is 18"  
tall and is supplied with a standard 2" pipe size  
(2 3/8" O.D.) tenon.  
TWIN ARM MOUNT TENON [TMT]  
Soft form extruded aluminum arm is 24" in length  
and features two (2) standard 2" pipe size (2 3/8"  
O.D.) tenons for twin fixture mount. Other lengths  
and drilling patterns available upon request. Twin  
arm base slip fits over standard 2" pipe size (2 3/8"  
O.D.) tenon. End caps are removable for wiring  
access. Useful in ground mount and pole mount  
applications. For extended downward aiming, utilize  
PM1 or PM2 in conjunction with TMT.  
WALL MOUNT ARM TENON [WMT]  
Extruded aluminum arm with cast mounting plate  
is 15" in length and is supplied with a standard 2"  
pipe size (2 3/8" O.D.) tenon. Also useful as an arm  
extension off square area light pole.  
20  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPTIONS + ACCESSORIES SPECIFICATIONS  
- Specifications + Dimensions  
EXTERNAL GRID LOUVERS  
TOP VISOR  
4-SIDED SHIELD  
Designed to control lamp glare and spill light while  
maintaining beam efficiency. Useful when aiming  
direction or intended target lies in close proximity  
to pedestrian and/or motor vehicle activity. Mounts  
to accessory channel in doorframe. Finished in black  
powder coat paint. Compatible with all  
Controls excess spill and glare on top portion of  
distribution. Especially useful in uplighting  
applications to limit light travel above intended  
wall surface or sign. Mounts to accessory channel  
in doorframe. Compatible with all distributions.  
Controls lamp glare and spill light in all directions.  
Useful when aiming direction or intended target  
lies in close proximity to pedestrian and/or motor  
vehicle activity. Mounts to accessory channel in  
doorframe. Compatible with all distributions.  
Available on VFM only.  
distributions. Available on VFM only.  
Button-Style  
Photocontrol  
BARN DOORS  
VANDAL SHIELD  
PHOTOCELL CONTROL  
Four (4) independently mounted and adjustable  
doors control cutoff angles in all directions,  
allowing custom distribution control for any  
application. Compatible with all distributions.  
3/16" thick molded polycarbonate convex lens.  
Treated with UV inhibitor to discourage the gradual  
discoloration that results from exposure to sunlight  
and metal halide lamps.  
Internal button-style photocell with sensor located  
on backside of housing.  
21  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ORDERING INFORMATION  
Sample Number: VFM-K-400-MH-MT-MF-GM-L  
Product Family  
VFS=Vision Flood  
Small  
Lamp  
Voltage4  
Colors  
Options (add as suffix)  
Accessories  
1
6
Wattage  
50=50W  
70=70W  
120=120V  
208=208V  
240=240V  
277=277V  
347=347V  
480=480V  
DT=Dual-Tap  
(add as suffix/must specify) F=Single Fuse  
(order separately, replace XX with color suffix)  
VFS  
BK=Black  
(120, 277, or 347V) Specify Voltage  
VFM=Vision Flood  
AP=Grey  
FF=Double Fuse  
JB-XX=Architectural J-Box  
Medium  
100=100W  
150=150W  
175=175W  
250=250W  
320=320W2  
350=350W2  
400=400W  
750=750W3  
1000=1000W3  
BZ=Bronze  
(208, 240 or 480V) Specify Voltage  
SM-XX=Stanchion Mount  
7
WH=White  
Q=Quartz Restrike  
ST-XX=Stanchion Mount Tenon  
Mounting  
Type  
K=Knuckle  
DP=Dark Platinum  
GM=Graphite Metallic  
EM=Quartz Restrike with Delay  
(Also Strikes at Cold Start) 7  
EM/SC=Quartz Emergency  
Separate Circuit 7  
PC=Button Type Photocontrol (Specify Voltage)  
L=Lamp Included  
WM-XX=Wall Mount  
WMA-XX=Wall Mount Arm  
wired 277V5  
WMT-XX=Wall Mount Arm Tenon Mount  
TMA-XX=Twin Mount Arm—EPA 0.35  
TMT-XX=Twin Mount Arm Tenon Mount—EPA 0.42  
SF-XX=Slipfitter  
MT=Multi-Tap  
wired 277V5  
TT=Triple-Tap  
wired 347V5  
PM1-XX=Post Mount Extension Single—EPA 0.12  
PM2-XX=Post Mount Extension Double—EPA 0.12  
SMT-XX=Surface Mount Tenon  
VFS-BD-XX=Barn Doors—EPA 1.01  
VFS-TV-XX=Top Visor—EPA 0.6  
VFS-VS=Vandal Shield  
VFS-CFR-XX=Color Filter Adapter with Red Gel  
VFS-CFB-XX=Color Filter Adapter with Bright Blue Gel  
VFS-CFG-XX=Color Filter Adapter with Deep Green Gel  
VFS-CFO-XX=Color Filter Adapter with Warm Orange Gel  
VFM  
SMT-XX=Surface Mount Tenon  
ST-XX=Stanchion Mount Tenon  
Distribution  
Lamp Type  
NS=Narrow Spot  
NF=Narrow Flood  
MF=Medium Flood  
WF=Wide Flood  
VF=Vertical Flood  
HS=Horizontal Spot  
MH=Metal Halide  
MP=Pulse Start  
Metal Halide  
HPS=High Pressure  
Sodium  
NOTE: 1 All lamps are mogul-base on VFM fixtures and medium-base on VFS. 2 320/350W Pulse Start Metal Halide lamps only.  
3 Metal Halide only, requires reduced envelope BT or ED37 lamp. 4 Products also available in non-US voltages and 50Hz for  
international markets. Consult factory for availability and ordering information. 5 Dual-Tap is 120/277V wired 277V. Multi-Tap is  
120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V wired 347V. 6 RAL and custom color matches available.  
Consult your INVUE Lighting Systems Representative for more information. 7 Quartz options available on VFM only.  
TMT-XX=Twin Mount Arm Tenon Mount—EPA 0.42  
WMT-XX=Wall Mount Arm Tenon Mount  
VFM-BD-XX=Barn Doors  
VFM-TV-XX=Top Visor  
VFM-4S-XX=4-Sided Shield  
VFM-VS=Vandal Shield  
DIMENSIONS  
Vision Flood Small [VFS]  
VFM-GL=External Grid Louvers  
Vision Flood Medium [VFM]  
VFM-CFR-XX=Color Filter Adapter with Red Gel  
VFM-CFB-XX=Color Filter Adapter with Bright Blue Gel  
VFM-CFG-XX=Color Filter Adapter with Deep Green Gel  
VFM-CFO-XX=Color Filter Adapter with Warm Orange Gel  
10"  
[254 mm]  
16 1/2"  
[419 mm]  
X
7 1/2"  
[191 mm]  
X=2 15/16"  
[75 mm]  
14" [356 mm]  
7 11/16"  
[196 mm]  
23" [584 mm]  
11 13/64" [284 mm]  
WATTAGE TABLE  
SHIPPING DATA  
VFS  
VFM  
VFS  
VFM  
Metal Halide  
50, 70, 100, 175W 175, 250, 400, 1000W  
250, 320, 350, 400, 750W  
50, 70, 100, 150W 150, 250, 400W  
Net. Weight (lbs.)  
37  
53  
Pulse Start Metal Halide  
High Pressure Sodium  
E.P.A. (lbs.)  
1.19  
3.24  
NOTE: The above are approximate weights.  
STANDARD COLORS  
BK  
Black  
AP  
Grey  
BZ  
Bronze  
WH  
White  
DP  
GM  
Graphite Metallic  
Dark Platinum  
APPLICATIONS DEPARTMENT  
Let the application experts at Cooper Lighting design your next lighting layout. Aided by the latest computer simulation software and a comprehensive lighting background,  
our Application Engineers can design, analyze, and provide statistical layouts for any lighting application. Whether the design criteria calls for Illuminance, Luminance, or  
Small Target Visibility (STV) compliance, Cooper Lighting can provide the fixture layout and supporting documentation necessary to help secure your next project.  
INVUE WEBSITE  
Visit invuelighting.com for the latest product information from INVUE Lighting Systems. With instant access to IES photometric files, PDF product specification sheets, new  
product announcements, and other helpful specification tools, the INVUE Lighting website is an invaluable resource for getting information to customers-quickly.  
22  
VISION FLOOD Architectural Flood Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CUSTOMER FIRST CENTER  
1121 HIGHWAY 74 SOUTH  
PEACHTREE CITY, GEORGIA 30269  
770.486.4800  
The Cooper Lighting Family  
Halo  
Portfolio  
Metalux  
FAX: 770.486.4801  
Neo-Ray  
Corelite  
Lumark  
Domestic Facilities, USA  
Cranbury, New Jersey  
Elk Grove Village, Illinois  
Irving, Texas  
Ontario, California  
Peachtree City, Georgia  
INVUE  
McGraw-Edison  
Streetworks  
Sure-Lites  
Fail-Safe  
Shaper  
Iris  
International Sales, USA  
Lumie` re  
Peachtree City, Georgia  
MWS  
CANADA  
Cooper Lighting  
5925 McLaughlin Road  
Mississauga, Ontario L5R 1B8  
905.507.4000  
Fax: 905.586.7049  
Domestic Facilities, Canada  
Calgary, Alberta  
Chomedey, Laval P.Q.  
Cooper Lighting  
All rights reserved  
Printed in USA  
VISION FLOOD  
ARCHITECTURAL FLOOD LUMINAIRE  
AVU031495  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Continental Electric Mixer CP43189 User Manual
Cuisinart Coffee Grinder DBM 8 User Manual
Curtis MP3 Player MPK4050 User Manual
Cypress Computer Hardware CY62157ESL User Manual
Eagle Electronics Fish Finder 642c User Manual
Eagle Electronics Grinder EGA530 User Manual
EDGE Tech Pager X PAGE User Manual
Electro Voice Microphone PL80c User Manual
FEIN Power Tools Welder FSC 16 User Manual
GE Air Conditioner ASW18 User Manual