Cooper Lighting Indoor Furnishings VT3 132 User Manual

®
COOPER LIGHTING - METALUX  
DESCRIPTION  
Type  
The VT3 Series is a contemporary looking energy efficient industrial  
Vaportite fixture that features rugged and durable construction. The VT3  
incorporates a full metal clear tray inside a reinforced fiberglass housing  
with a high impact diffuser. This Vaportite series is suitable for interior and  
exterior applications and can be surface or chain mounted.  
Catalog #  
Project  
Date  
Comments  
Prepared by  
The VT3 Series has been designed for maximum operation in commercial  
institutional and industrial environments where weathering, high  
temperature, humidity and dust or corrosive fumes are present.  
SPECIFICATION FEATURES  
A ... Construction  
B ... Electrical*  
Unit has full metal gear tray  
C ... Shielding  
Fiberglass housing is reinforced  
polyester and self-extinguishing  
(ASTM-D635-74) plastic of a  
permanent pearl gray color. Top of  
housing has five embossments (2'  
unit), nine embossments (4' unit)  
and thirteen embossments (8'  
unit), providing mounting flexibi-  
lity on uneven surfaces. A watertite  
hub for 1/2" conduit entry is  
provided at each end of housing  
(standard) for continuous feed.  
Polyurethane gasketing is formed  
in the housing providing a  
New contemporary styled lens  
clear acrylic w/impact resistant  
additives and linear prisms.  
"DR" - Clear low brightness pattern  
acrylic with 15% high impact  
additive.  
secured by internal fasteners and  
tethers providing maximum  
protection and rigidity. Ballasts are  
CBM/ETL Class "P" certified  
suitable to 70°F. (Cold temperature  
ballasts are available for less than  
0°F starting with EHT (T5HO only),  
EB/PLUS and ER/PLUS Ballasts).  
Rotor lock lampholders. Electrical  
components and fixtures are  
UL/CUL listed for Wet Locations.**  
IP65 approved with optional IP67  
rating (4' only) with 8 latches.  
"DR-100" - Clear low brightness  
pattern acrylic with 100% high  
impact additive. Example:  
VT3-232DR-100  
VT3  
132  
continuous seamless seal for the  
diffuser. Six sturdy cam latches  
clamp diffuser tightly for a positive  
seal between housing, gasketing  
and diffuser.  
232  
332  
A
B
C
154T5  
254T5  
4-13/16"  
[123mm]  
4' INDUSTRIAL  
1, 2 OR 3 LAMP  
Vaportite Industrial  
6-15/16"  
[177mm]  
MOUNTING DATA  
LAMP CONFIGURATIONS  
41-1/2" [1054mm]  
Optional Back Hub  
Locations  
X
X
4-13/16"  
4-13/16"  
[123mm]  
[123mm]  
38-3/4" [984mm]  
1/4" x 28" Stud  
(2 Places)  
ENERGY DATA  
Input Watts:  
EB Ballast & STD Lamps  
132 (30)  
Y
X=1-13/32"  
6-15/16"  
X=1-13/32"  
[36mm]  
[36mm]  
[177mm]  
6-15/16"  
[177mm]  
6-5/8"  
[168mm]  
Y=2-1/2"  
[64mm]  
232 (61)  
X
X=5-3/8"  
[137mm]  
Y=4-3/16"  
4-13/16"  
[123mm]  
Y
154T5 (54)  
X
254T5 (106)  
49-13/16" [1265mm]  
[107mm]  
Luminaire Efficacy Rating  
LER = FI-73  
Y
X=1-13/32"  
[36mm]  
6-15/16"  
[177mm]  
Catalog Number: VT3-232DR  
Y=2-1/2"  
[64mm]  
INSTALLATION DATA  
Yearly Cost of 1000 lumens,  
3000 hrs at .08 KWH = $3.29  
Relative Light Output Factors  
*Reference the lamp/ballast data in the  
Technical Section for specific lamp/ballast  
requirements.  
To accurately predict how luminaires will perform in cold temperatures,  
Cooper Lighting individually tested each configuration in the different  
ambient environments.The relative light output factor should be  
applied as an additional light loss factor component.  
**Not Suitable for Wet Locations if EL4  
Option is added. Consult Pre Sales  
Technical Support.  
VT3 Series  
MOUNTING OPTIONAL CHAIN HANGING SET  
-15°F (-26°C) 0°F (-18°C) 20°F (-6°C)  
33°F (0°C)  
0.97  
50°F (10°C)  
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING  
TO LOCAL, STATE OR FEDERAL LAWS  
BRACKETS  
(VT2-CHAIN/SET-U)  
Furnished  
Two per  
4' Unit  
VT3-232  
VT3-254  
VT3-332  
VT3-354  
0.67  
0.86  
0.96  
0.99  
0.94  
0.98  
Includes 6 ft. of chain, 4 large  
S-Hooks and 4 small S-Hooks  
Order One (1) Kit for each 4' Fixture  
0.73  
0.76  
0.90  
0.98  
Four per  
8' Unit  
Two (2) Kits Recommended For  
8' Fixture  
0.91  
0.93  
Safe and convenient means of  
disconnecting power  
Specifications and Dimensions subject to change without notice.  
ADF071376  
10/06/2008 11:40:01 AM  
Consult your representative for additional options and finishes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VT3  
PHOTOMETRICS  
Candela  
Candela  
VT3-232DR-UNV-  
EB81-WL-U  
(1) Electronic Ballasts  
VT3-254T5DR-UNV-  
EHT1-WL-U  
(1) Electronic Ballasts  
Angle  
0
Along II  
45°  
1103  
1108  
1107  
1091  
1089  
1058  
1035  
991  
952  
892  
831  
753  
683  
611  
Across  
1103  
1107  
1106  
1127  
1113  
1098  
1088  
1052  
1024  
971  
920  
878  
814  
771  
698  
592  
513  
427  
Angle  
0
5
Along II  
45°  
1546  
1525  
1548  
1514  
1509  
1487  
1446  
1396  
1315  
1267  
1174  
1081  
954  
Across  
1103  
1097  
1083  
1059  
1025  
983  
932  
870  
801  
725  
640  
548  
451  
352  
251  
155  
77  
1546  
1540  
1519  
1483  
1436  
1375  
1300  
1215  
1118  
1012  
896  
1546  
1533  
1525  
1546  
1566  
1530  
1509  
1502  
1425  
1384  
1308  
1179  
1107  
1101  
1044  
936  
(2) 32WT8 lamps  
2850 lumens  
(2) 54WT5 lamps  
4400 lumens  
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Spacing criterion:  
(II) 1.3 x mounting  
height, ( ) 1.5 x  
mounting height  
Spacing criterion:  
(II) 1.2 x mounting  
height, ( ) 1.5 x  
mounting height  
Efficiency 77.4%  
Efficiency 69.7%  
Test Report:  
LTL10864.IES  
Test Report:  
LTL10777.IES  
770  
634  
496  
352  
LER =FL72  
LER =FL59  
827  
771  
704  
Yearly Cost of 1000  
lumens, 3000 hrs at  
.08 KWH = $3.34  
550  
471  
367  
290  
217  
Yearly Cost of 1000  
lumens, 3000 hrs  
at .08 KWH = $4.05  
219  
113  
578  
807  
28  
6
47  
13  
432  
614  
342  
285  
431  
Coefficients of Utilization  
Effective floor cavity reflectance  
Coefficients of Utilization  
Effective floor cavity reflectance  
20%  
20%  
rc  
rw  
RCR  
0
1
2
3
4
5
6
80%  
70 50 30 10  
70%  
70 50 30 10  
50%  
50 30 10  
30%  
50 30 10  
10%  
50 30 10  
0%  
0
rc  
rw  
RCR  
0
1
2
3
4
5
6
80%  
70 50 30 10  
70%  
70 50 30 10  
50%  
50 30 10  
30%  
50 30 10  
10%  
50 30 10  
0%  
0
82 82 82 82  
74 70 66 63  
66 60 55 50  
60 52 46 41  
55 46 40 35  
50 40 34 29  
46 36 29 25  
42 32 26 21  
39 29 23 18  
36 26 20 16  
33 23 18 14  
80 80 80 80  
72 68 65 62  
64 58 54 49  
58 51 45 41  
53 45 39 34  
48 40 33 29  
44 35 29 24  
41 32 25 21  
38 28 22 18  
35 25 19 15  
32 23 17 14  
76 76 76  
65 62 59  
55 51 48  
49 44 40  
43 38 33  
38 32 28  
34 28 24  
30 25 21  
27 22 18  
24 19 15  
22 17 13  
72 72 72  
61 59 57  
53 49 46  
46 42 39  
41 36 33  
36 31 27  
32 27 24  
29 24 20  
26 21 17  
23 18 15  
21 17 13  
69 69 69  
58 57 55  
50 47 45  
44 41 38  
39 35 32  
34 30 27  
31 26 23  
28 23 20  
25 20 17  
22 18 15  
20 16 13  
67  
53  
43  
36  
30  
25  
22  
18  
16  
13  
12  
91 91 91 91  
82 78 74 70  
74 67 61 56  
67 58 52 46  
61 51 44 39  
56 45 38 32  
51 40 33 28  
47 36 29 24  
43 32 25 20  
40 29 22 17  
37 26 20 15  
89 89 89 89  
79 75 72 69  
71 65 60 55  
65 57 51 46  
59 50 43 38  
54 44 37 32  
49 39 32 27  
45 35 28 23  
42 31 25 20  
38 28 22 17  
36 26 19 15  
84 84 84  
71 68 66  
61 57 53  
54 49 44  
48 42 37  
42 36 31  
37 31 27  
33 27 23  
30 24 20  
27 21 17  
24 19 15  
79 79 79  
67 65 63  
58 54 51  
51 47 43  
45 40 36  
40 34 30  
36 30 26  
32 27 23  
29 23 19  
26 20 17  
23 18 15  
75 75 75  
64 62 60  
55 52 49  
49 45 42  
43 39 35  
38 33 30  
34 29 26  
30 26 22  
27 23 19  
25 20 16  
22 18 14  
73  
58  
47  
40  
33  
28  
24  
20  
17  
15  
13  
7
8
9
10  
7
8
9
10  
Zonal Lumen Summary  
Luminance Data  
Average  
Zonal Lumen Summary  
Luminance Data  
Average  
Average  
45-Deg  
cd/sm  
7213  
6756  
6377  
6097  
5151  
Average  
90-Deg  
cd/sm  
7212  
7098  
7074  
6510  
6092  
Average  
45-Deg  
cd/sm  
Average  
90-Deg  
cd/sm  
Angle  
in Deg  
0-Deg  
cd/sm  
Angle  
in Deg  
0-Deg  
cd/sm  
Zone  
0-30  
0-40  
0-60  
0-90  
0-180  
Lumens %Lamp  
%Fixture  
20.4  
Zone  
0-30  
0-40  
0-60  
0-90  
0-180  
Lumens %Lamp  
%Fixture  
20.4  
899  
15.8  
26.5  
49.9  
73.1  
77.4  
1253  
2112  
3985  
5908  
6137  
14.2  
24.0  
45.3  
67.1  
69.7  
45  
55  
65  
75  
85  
5519  
5083  
4347  
3001  
1349  
45  
55  
65  
75  
85  
7704  
7142  
6126  
4240  
2265  
10245  
9700  
8631  
9114  
10279  
9531  
10102  
10293  
8760  
1512  
2847  
4169  
4413  
34.3  
64.5  
94.5  
34.4  
64.9  
96.3  
100.0  
100.0  
7674  
ORDERING INFORMATION  
SAMPLE NUMBER: VT3-232DR-UNV-EB81-WL-U  
BallastType(1), (4)  
EB8 =T8 Electronic Instant Start.  
Total Harmonic Distortion < 10%  
No. of Ballast  
1 or 2  
Packaging  
U=Unit Pack  
WL=Wet Label  
Voltage(1)  
Tandem  
Blank= 4' Length  
8T=8' Length  
120V=120 Volt  
277V=277 Volt  
347V=347 Volt  
UNV=Universal  
Voltage 120/277 (2)  
UNC=Universal  
Voltage 347/480  
Options  
8L=8 Latches (IP67 Rating)  
M4=Miro 4 Interior Reflector  
RIF1=Radio Interference  
Suppressor  
Series  
VT3=Vaportite  
EB8 /PLUS=T8 Electronic Instant Start.  
High Ballast Factor >1.13.Total  
Harmonic Distortion < 20%  
Number of Lamps(3)  
No. of  
Ballast  
1 or 2  
TH=(2)Top Watertite Hubs  
1, 2 or 3 Lamps  
only, no End Hubs(5)  
(Not included)  
GL=Single Element Fuse  
GM=Double Element Fuse  
EL=Emergency Installed(3), (4)  
TEH=(2)Top & (2) End(5)  
Watertite Hubs (all Watertite  
Hubs have 1/2" Conduit  
Entry)  
ER8 =T8 Electronic Program Rapid Start.  
Total Harmonic Distortion < 10%  
No. of Ballast  
1 or 2  
Wattage (Length)  
32=32WT8 (48")  
28T5=28WT5 (48")  
SSL=Stainless Steel Latches  
54T5=54WT5HO (48")(5)  
EBT =T5 Linear Electronic Program Rapid Start.  
Total Harmonic Distortion < 10%  
No. of Ballast  
1 or 2  
Lens  
DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard)  
DR-50=50% High Impact Additive (High Impact)  
DR-100=100% High Impact Additive (Extreme)  
EHT =T5 Linear Electronic Start High Ambient.  
Total Harmonic Distortion < 10%  
No. of Ballast(3)  
1 or 2  
NOTES: (1) Products also available in non-US voltages and frequencies for international  
markets. (2) Not available when specifying emergencies, voltage must be specific. (3)  
Lamp 54WT5HO is recommended for ambient temperatures below 102°F (40°C) with  
EHT2 ballasts, and below 0°F (-18°C) with EHT1 ballast. (4)Emergency option in 3 lamp  
version must use remote mount test switch. (5)Top Hub required when stem mounting.  
3
ACCESSORIES  
SHIPPING INFORMATION  
For complete product data, reference the Fluorescent Specification binder. Specifications &  
dimensions subject to change without notice. Consult your Cooper Lighting  
Representative for availability and ordering information.  
Catalog No.  
Wt.  
Accessories (order separately)  
VT2-Chain/Set-U=Chain Hanging Set  
Includes 6 ft. of chain, 4 large S-Hooks and 4  
small S-Hooks  
VT3-132 DR-WL  
VT3-232 DR-WL  
VT3-154T5  
16 lbs.  
16 lbs.  
16 lbs.  
16 lbs.  
Order One (1) Kit for each 4' Fixture  
VT3-254T5  
Two (2) Kits Recommended For 8' Fixtures.  
VT2-SS-MBK=Stainless Steel Mounting  
Bracket  
Specifications and Dimensions subject to change without notice.  
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801  
ADF071376  
10/06/2008 11:40:01 AM  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clover Electronics Security Camera HDC518 User Manual
Coleman Tent 2000008494 User Manual
Cooper Lighting Landscape Lighting PSL User Manual
Craftsman Chipper 247795940 User Manual
Cub Cadet Lawn Mower Z Wing 48 User Manual
Danby Freezer DUFM454WDB User Manual
Dimplex Indoor Fireplace DFI2309 User Manual
Electro Voice Stereo Amplifier CPS 26 User Manual
Gaggenau Ventilation Hood AH 590 720 User Manual
GE Monogram Ventilation Hood ZV48RSFSS User Manual