COOPER LIGHTING - METALUX
DESCRIPTION
Type
The VT2 Series is an energy efficient industrial Vaportite fixture that features
rugged and durable construction. The VT2 incorporates a full metal fixture
liner inside a reinforced fiberglass housing with a high impact diffuser. This
Vaportite series is suitable for interior and exterior applications and can be
surface or chain mounted.
Catalog #
Project
Date
Comments
Prepared by
The VT2 Series has been designed for maximum operation in commercial
institutional and industrial environments where weathering, high
temperature, humidity and dust or corrosive fumes are present.
SPECIFICATION FEATURES
A ... Construction
B ... Electrical*
C ... Lens
Fiberglass housing is reinforced
polyester and self-extinguishing
(ASTM-D635-74) plastic of a
Unit has full metal liner (channel)
secured by brass internal/external
mounting studs for positive
grounding, maximum protection
and rigidity. Ballasts are CBM/ETL
Class "P" certified suitable to plus
50°F. Spring loaded lampholders.
Electrical components and fixtures
are UL/CUL listed for Wet
"DR" - Clear low brightness pattern
acrylic with 15% high impact
additive.
permanent pearl gray color. Top of
housing has nine embossments
(4' unit) and thirteen embossments
(8' unit), providing mounting
flexibility on uneven surfaces. A
watertight hub for 1/2" conduit
entry is provided at each end of
housing (standard) for continuous
feed. Polyurethane gasketing is
formed in the housing providing a
continuous seamless seal for the
diffuser. Six sturdy cam latches (4'
unit) and twelve (8' and tandem
unit) clamp diffuser tightly for a
positive seal between housing,
gasketing and diffuser.
"DR-100" - Clear low brightness
pattern acrylic with 100% high
impact additive.
Example: VT2-296DR-100
"LEX" - High impact clear low
brightness pattern polycarbonate.
LEXAN
Locations.**
IP65 approved (4' only).
Example: VT2-296LEX.
D ... Reflectors
Optional die formed finished or
95% specular miro reflector.
VT2
132
232
332
A
B
C
154T5
254T5
5-7/8"
[149mm]
4' OR 8' INDUSTRIAL
1, 2 OR 3 LAMP T8
1 OR 2 LAMP T5HO
7" [178mm]
LAMP CONFIGURATIONS
MOUNTING DATA
Vaportight Industrial
1-lamp
2-lamp
41-1/2" [1054mm]
Optional Back Hub
Locations
Z
Z
Y
Y
5"
5"
[127mm]
[127mm]
X
X
38-3/4" [984mm]
1/4" x 28" Stud
(2 Places)
W
6-5/8"
[168mm]
7"
6-5/8"
[168mm]
7"
W=2-5/8"
[67mm]
ENERGY DATA
6-5/8"
[168mm]
Input Watts:
[178mm]
X=2-1/8"
[54mm]
[178mm]
EB Ballast & STD Lamps
132 (36), 232 (57), 332 (82)
3-lamp (T8 Only)
Y=3-3/16"
[81mm]
X=5-3/8"
[137mm]
Y=5-3/8"
[102mm]
Y
X
Z
Y
5"
EB Ballast &T5HO Lamps
Z=1-1/2"
[38mm]
[127mm]
49-13/16" [1265mm]
X
254T5 (121), 8T254T5 (242)
W
6-5/8"
[168mm]
7"
EB Ballast &T5HO Lamps
89-1/2" [2273mm]
Optional Back Hub
Locations
154T5 (62), 254T5 (117)
EB Plus Ballast & STD Lamps
[178mm]
87-1/16" [2211mm]
1/4" x 28" Stud
(4 Places)
132 (46), 232 (73), 332 (108)
Luminaire Efficacy Rating
LER = FI-73
6-5/8"
[168mm]
Catalog Number: VT-232DR
Yearly Cost of 1000 lumens,
X=5-3/8"
[137mm]
Y=5-3/8"
[102mm]
X
40-13/16"
[1037mm]
5-1/8"
[130mm]
40-13/16"
[1037mm]
Y
3000 hrs at .08 KWH = $3.29
97-13/16" [2484mm]
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
INSTALLATION DATA
**Not Suitable for Wet Locations if EL4
Option is added. Consult Pre Sales
Technical Support.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
OPTIONAL CHAIN HANGING SET
(VT2-CHAIN/SET-U)
MOUNTING BRACKETS
Furnished
Includes 6 ft. of chain, 4 large S-Hooks and 4
small S-Hooks
Two per 2' and 4' Unit
Four per 8' Unit
Order One (1) Kit for each 2' or 4' Fixture
Two (2) Kits Recommended For 8' Fixture
Safe and convenient means of
disconnecting power
Specifications and Dimensions subject to change without notice.
ADF071394
09/29/2008 10:06:07 AM
Consult your representative for additional options and finishes.
Download from Www.Somanuals.com. All Manuals Search And Download.
VT2
PHOTOMETRICS
Candlepower
Candlepower
VT2-254DR-UNV-
EB81-WL-M4-U
VT2-232DR-UNV-
EB81-WL-M4-U
Angle
0
5
Along II
1615
1613
1592
1556
1504
1438
1357
1262
1154
1033
902
762
621
485
362
253
158
74
26
45°
1615
1632
1673
1704
1717
1712
1683
1625
1532
1412
1263
1101
944
775
667
677
612
455
297
Across ?
1615
1648
1723
1781
1820
1839
1815
1743
1635
1499
1355
1180
994
Angle
0
5
Along II
1036
1036
1023
1000
968
926
876
817
750
674
45°
1036
1059
1114
1175
1227
1255
1245
1184
1080
961
834
706
597
533
520
489
396
302
Across ?
1036
1077
1175
1275
1344
1352
1284
1182
1070
946
833
780
785
816
755
624
518
434
Electronic Ballast
Electronic Ballast
?
(2) F54/T5/835 Lamps
4460 Lumens each
(2)T8 Lamps
2850 Lumens each
?
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Spacing criterion:
(II) 1.2 x mounting
height, (? ) 1.6 x
mounting height
Spacing criterion:
(II) 1.3 x mounting
height, (? ) 1.6 x
mounting height
||
||
Efficiency 74.3%
Efficiency 81.7%
Test Report:
127P111
Test Report:
127P113
591
501
408
317
233
160
97
LER = FI57
LER = FI71
968
1051
992
827
647
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.24
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.39
45
16
463
224
353
Coeffi cients of Utilization
Effective floor cavity reflectance
Coeffi cients of Utilization
Effective floor cavity reflectance
20%
20%
rc
rw
RCR
0
1
2
3
4
5
6
80%
70 50 30 10
70%
70 50 30 10
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
rc
rw
RCR
0
1
2
3
4
5
6
80%
70 50 30 10
70%
70 50 30 10
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
87 87 87 87
78 73 70 66
70 63 57 52
64 55 48 43
58 48 41 36
53 43 36 31
49 39 32 27
45 35 28 23
42 32 25 21
39 29 23 18
37 27 21 17
85 85 85 85
75 71 68 65
68 61 56 51
61 53 47 42
56 47 40 35
51 42 35 30
47 38 31 26
44 34 28 23
41 31 25 20
38 28 22 18
36 26 20 16
80 80 80
67 64 62
58 53 50
51 45 41
45 39 34
40 34 30
36 30 26
32 27 23
30 24 20
27 22 18
25 20 16
76 76 76
64 61 59
55 51 48
48 43 40
42 38 34
38 33 29
34 29 25
31 26 22
28 23 20
26 21 18
24 19 16
72 72 72
60 59 57
52 49 46
45 42 39
40 36 33
36 32 28
33 28 25
30 25 22
27 23 19
25 21 17
23 19 16
70
55
44
37
31
26
23
20
18
16
14
96 96 96 96
86 81 77 73
77 69 63 58
70 60 53 47
64 53 45 40
58 47 39 34
54 42 35 29
50 38 31 26
46 35 28 23
43 32 25 20
40 29 23 18
93 93 93 93
83 78 74 71
74 67 61 57
67 59 52 46
61 52 44 39
56 46 39 33
52 41 34 29
48 37 30 25
45 34 27 22
42 31 25 20
39 29 22 18
87 87 87
74 70 68
63 58 54
55 49 45
49 43 38
44 37 32
39 33 28
35 29 25
32 26 22
30 24 20
27 22 18
82 82 82
69 67 64
60 56 52
52 47 43
46 41 37
41 36 31
37 32 27
34 28 24
31 25 21
28 23 19
26 21 17
78 78 78
65 63 61
56 53 50
49 45 42
44 39 35
39 34 31
35 30 27
32 27 24
29 25 21
27 22 19
25 20 17
76
59
48
40
33
29
25
22
19
17
15
7
8
9
10
7
8
9
10
Zonal Lumen Summary
Luminance Data
Average
Zonal Lumen Summary
Luminance Data
Average
Average
Average
90-Deg
cd/sm
11288
10954
12196
20408
39527
Average
Average
90-Deg
cd/sm
5343
4906
5995
5721
5512
Angle
0-Deg
cd/sm
45-Deg
cd/sm
Angle
0-Deg
cd/sm
45-Deg
cd/sm
Zone
0-30
0-40
0-60
0-90
0-180
Lumens %Lamp
%Fixture
21.3
Zone
0-30
0-40
0-60
0-90
0-180
Lumens %Lamp
%Fixture
21.1
in Deg
in Deg
1411
2397
4380
6268
6614
15.8
26.9
49.1
70.3
74.2
985
1675
2999
4316
4658
17.3
29.4
52.6
75.7
81.7
45
55
65
75
85
7779
7074
6110
5205
4251
10632
10221
9764
13928
27797
45
55
65
75
85
4874
4392
3669
2853
1868
6095
5171
4791
5921
5874
36.2
66.2
94.8
36.0
64.4
92.7
100.0
100.0
ORDERING INFORMATION
SAMPLE NUMBER: 8TVT2-254DR-UNV-EB82-M4-U
Voltage (1)
WL=Wet
Location
Label
Packaging
U=Unit Pack
PALC=Job
Options
RIF1=Radio
Interference Suppressor
TH=(2)Top Watertite Hubs
TEH=(2)Top & (2) End Watertite
Hubs (all Watertite Hubs have 1/2"
Conduit Entry)
Width
Blank=4' Length
8T=8' Length
BallastType (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
UNV=Universal
Voltage 120/277V
UNC=Universal
Voltage 347/480V
(T5 Linear Only)
T8 Systems
Pack in Carton
EB8 =T8 Electronic Instant Start.(4)
Series
VT2=Vapor-Tite
Total Harmonic Distortion < 20%
No. of Ballast
1 or 2
TILW=Tandem In-Line Wiring
Number of Lamps(3)
1=1 lamp (T5 orT8)
2=2 lamps (T5 orT8)
EB8 /PLUS=T8 Electronic Instant Start.
Option (ConsultTILW Option Catalog Page)
High Ballast Factor >1.13.Total
Harmonic Distortion < 20%
No. of
Ballast
1 or 2
PI/CPI=Plug-In Option
DD=Deep Diffuser (4' Length)
(Available for 4' Fixture Length)To Complement
Deep Diffuser Depth of 8' Fixture
3=3 lamps (T8 only)
Fusing
(Lamps not included)
GL=Single Element Fuse
GM=Double Element Fuse
Emergency=EM Installed,
see EM options table(3) (4)
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
LampType
32=32WT8 Lamp (4' Long)
54T5=54WT5HO Lamp (4' Long)
M4=Specular Reflector
SSL=Stainless Steel Latches
ER8 /PLUS=T8 Electronic Program Start.
ACCESSORIES
High Ballast Factor >1.13.Total
Harmonic Distortion < 10%
Lens
No. of
Ballast
DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard)
DR-100%=100% High Impact Additive
LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern
Accessories (order separately)
VT2-Chain/Set-U=Chain Hanging Set
Includes 6 ft. of chain, 4 large
S-Hooks and 4 small S-Hooks
1 or 2
EB8 /L=T8 Electronic Instant Start w/0.80
Ballast Factor.
No. of Ballast
1 or 2
T5 Systems
EBT =T5HO Electronic Program Start.
Order One (1) Kit for each
2' or 4' Fixture
Two (2) Kits Recommended
For 8' Fixture
NOTES: (1)Ballast type used only if ballast & voltage is chosen (2)Not available when specify-
ing emergencies, voltage must be specific. (3) T5HO is only available in 1 or 2-lamp versions
only. (4)Emergency option in 3 lamp version must use remote mount test switch.
VT2-SS-MBK=Stainless
Steel Mounting Bracket
No. of Ballast
1 or 2
SHIPPING DATA
Catalog No.
Wt.
VT2-132DR-WL
VT2-232DR-WL
35 lbs.
35 lbs.
Specifications and Dimensions subject to change without notice.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADF071394
09/29/2008 10:06:07 AM