FAIL-SAFE
Type
DESCRIPTION
The Fail-Safe MAF Series is designed for use in horizontal or non-laminar air
flow clean rooms. The enclosed and gasketed housing and one-piece, out-
side flanged door protect against infiltration of airborne bacteria. The die
formed edges on the door frame and the hole-free design of the housing
prevent air exchange between the fixture and plenum, allowing relamping
without contamination of the clean areas. These luminaires are U.L. listed
and C.S.A. certified for wet locations and manufactured in accordance with
U.S.D.A., F.D.A., N.S.F. and Federal Standard 209E guidelines. Rated for
high pressure hose down at 200 PSI.
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Application
D ... Lamps
(By Others)
H ... Ballast
Standard Class P, CBM/ETL ballast.
Applications include surgical
suites, clean rooms, technical and
biomedical labs, food processing/
testing centers and pharmaceutical
labs.
E ... Lens Retention
I ... Gasket
Unique, Particulock(TM) lens
retention system utilizes
continuous, 18 ga. media
clampdowns to sandwich
gasketing and integrate lens and
door frame for even environmental
seal.
White, closed cell, Flexiseal(TM)
gasketing surrounds perimeter of
lens to seal lens to door frame and
around perimeter of door to seal
door to housing. Another layer on
the flange seals fixture to ceiling
system after installation.
A ... Lens
(To be specified.) One-piece, clear
extruded lens with internal prism
pattern. Choice of prismatic acrylic,
prismatic polycarbonate, Radialens
(TM) or prismatic tempered glass
on environmental side. See Lens
Options.
F ... Hinge
J ... Access
MAF
Two braided, stainless steel cables
on one side of door provide
hinging.
A gasketed access plate on top of
the housing with two flattened,
7/8" diameter knockouts allows
connection of vapor tight conduit
fitting.
B ... Fasteners
17W - 40W
Fluorescent
Flush mounted, stainless steel
machine screws secure through
captive cage nuts in housing and
are evenly spaced to compress
gasketing on all sides.
G ... Door
(To be specified.) One-piece, 18
ga., fully gasketed, outside flanged
door with die-formed edges
eliminates seams which could
entrap microscopic contaminants.
1' X 4'
FLUORESCENT FLANGE
Symmetric/Asymmetric Lens
One-Piece Door
Labels
U.L. listed, C.S.A. certified,
standard wet label.
C ... Housing
Die-formed, 20 ga. CRS with tightly
butted and seam welded, sealed
end caps. Contains no holes that
would allow air passage. Standard
white high reflectance polyester
powder coat finish. Gloss: 85%;
Reflectance: 93%; Hardness: 2H;
Salt Spray: 500 Hours.
H
J
D
C
4 3/8"
[111mm]
4"
B
[102mm]
F
I
G
E
10 3/4"
[273mm]
12 1/4"
[311mm]
A
14"
[356mm]
MOUNTING DIMENSIONS
(4) 3/16" [5mm] Dia.
Yoke Mounting Hole
(2) 7/8" [22mm] KO
Gasketed Access Plate
ENERGY DATA
Input Watts:
STD Ballasts & STD Lamps
11 1/16" [281mm]
Ceiling Cut-Out
(1) 20W T12 Fluorescent: 32W
(2) 20W T12 Fluorescents: 53W
(3) 20W T12 Fluorescents: 85W
(1) 40W Biaxial Fluorescent: 45W
(2) 40W Biaxial Fluorescents: 82W
3 11/16"
[94mm]
13 1/4"
[336mm]
1 1/2"
[38mm]
36"
ES Ballasts & STD Lamps
[914mm]
(1) 17W T8 Fluorescent: 23W
(2) 17W T8 Fluorescents: 45W
(3) 17W T8 Fluorescents: 68W
(1) 32W T8 Fluorescent: 37W
(2) 32W T8 Fluorescents: 71W
(3) 32W T8 Fluorescents: 108W
(1) 40W T12 Fluorescent: 50W
(2) 40W T12 Fluorescents: 86W
(3) 40W T12 Fluorescents: 136W
48 5/16" [1227mm]
Ceiling Cut-Out
LAMP CONFIGURATIONS
DOOR FRAME
3"
[76mm]
1 3/4"
[44mm]
1 3/4"
[44mm]
2"
[51mm]
Flange Type-One-Piece Door
ES Ballasts & ES Lamps
(1) 40W T12 Fluorescent: 44W
(2) 40W T12 Fluorescents: 76W
(3) 40W T12 Fluorescents: 120W
Electronic Ballast Data:
Consult Factory
Specifications and Dimensions subject to change without notice.
ADC041684
09/22/2008 12:05:52 PM
Consult your representative for additional options and finishes.
Download from Www.Somanuals.com. All Manuals Search And Download.
MAF
PHOTOMETRICS
Zonal Lumen Summary
Candlepower Distribution
Average
Luminance
Zone
0-30
Lumens
1741
2775
4105
4643
0
%Lamp
18.1
28.9
42.8
48.4
0.0
%Luminaire
37.5
Test No. 5892
Deg.
CFF-12-340
45
55
65
75
85
2018
1332
1074
1124
1044
1833
1227
1010
1050
927
0-40
59.8
400
800
Lamp=F40T12RS/WW
No. Lamps=3
0-60
88.4
0-90
100.0
0.0
Lumens=3200
90-180
0-180
Spacing Criteria
=1.2 =1.1
Efficiency=38.7%
4643
48.4
100.0
1200
1600
2000
Coefficient of Utilization
rc
80%
70%
50%
30%
10%
0%
0
rw 70
50
30
10
50
30
10
50
10
50
10
50
10
RCR
0
58
54
50
46
43
40
37
34
32
29
58
52
47
42
38
34
31
28
26
23
21
58
50
44
39
35
31
28
25
22
20
18
58
49
42
36
32
28
25
22
29
17
18
56
51
46
41
38
34
31
28
25
23
21
56
49
43
38
34
30
27
25
22
19
18
56
48
41
36
32
28
25
22
19
17
15
54
49
44
40
36
33
30
27
25
22
21
54
46
40
35
31
27
25
22
19
17
15
51
47
43
39
35
32
29
27
24
22
20
51
45
39
35
31
27
24
22
19
17
15
49
45
41
38
34
31
29
26
24
21
20
49
44
39
34
30
27
24
22
19
17
15
48
43
38
33
30
26
23
21
18
16
14
1
2
3
4
5
6
7
8
9
10 27
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
ORDERING INFORMATION
Specifications and Dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADC041684
09/22/2008 12:05:52 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
|