Cooper Lighting Indoor Furnishings 201 IW User Manual

NEO-RAY  
ORDERING INFORMATION:  
Sample number: 201IW-SP-1T5HO-1C-120-SU-WA-24  
2-1/2"  
[63mm]  
S
Series  
201IW=Shell II Wall Mount  
Optics Up  
S=Specular  
7-7/8" [200mm]  
T8 = 1 Lamp  
T5 = 1 or 2 Lamp  
Optics Down  
P=Perforated  
Construction  
Housing is one-piece, die-formed, cold rolled steel,  
forming a 7-7/8” x 2-3/4” architectural profile.  
Perforated sections are 33% with staggered hole  
pattern with white acrylic overlay. Standard 4’-0”  
and 8’-0” luminaire lengths combine for continuous  
runs.  
Number of Lamps (not included)  
1=1 Lamp 2=2 Lamps (T5 only)  
SHELL II  
201-IW  
Lamp Type  
T5HO=54W HO (4’ Unit) T8=32W (4’ Unit) (1 Lamp only)  
Number of Circuits 1  
1=1 Circuit  
2=2 Circuits (Side by Side)  
End Caps  
Standard end caps are precision die-cast aluminum  
mechanically attached without exposed fasteners.  
DIRECT-INDIRECT  
Wiring  
C=Standard Circuit  
D=Dimming  
E=Emergency/Night Light  
B=Battery Pack  
Reflectors  
• Semi – indirect light  
distribution.  
Voltage 1  
1=120V  
Reflector is die-formed, semi- specular anodized  
aluminum.  
2=277V  
3=347V  
U=Universal  
• T5 and T8 lamping options.  
SU-WA=Surface/Wall Mount  
• Die formed steel perforated  
housings.  
Electrical  
Luminaires are prewired with quick wire connectors  
and use UL list Class P, T5HO or T8 electronic  
ballasts. Power factor of 97% with less than 10%  
THD. Fixtures and electrical components certified to  
UL and CUL standards.  
Run Length  
Individual or continuous runs will be configured with 4’ and 8’  
sections only (see sample catalog #)  
• Modular housing lengths –  
4’and 8’ for individual or  
continuous runs.  
1 Due to various constraints, some options may not be combined with others.  
• Precision die cast end caps.  
Finish  
• Adjustable mounting block  
for accurate leveling.  
Luminaire housings are standard white using  
electrostatically applied acrylic powder coat paint.  
Mounting  
Fixture mounts directly to existing structure over a  
2” x 4” standard electrical box mounted  
horizontally in the wall.  
= Slim Line Ballast only.  
S
STANDARD LUMINAIRE LENGTHS*  
48"[1219mm]*  
96"[2438mm]*  
*Dimensions do not include end caps.  
END CAP  
2-1/2"  
[64mm]  
7-1/8" [181mm]  
1-1/4"  
[38mm]  
NOTES: For complete product data, refer to the Neo-Ray Specification Binder. Specifications and dimensions subject to change without notice. Products may be  
modified for use in international markets. Please contact your Cooper Lighting Sales Representative for availability and ordering information.  
738 COOPER LIGHTING  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion CD Player DXZ366MP User Manual
Cooper Lighting Landscape Lighting OVF15SWW2D4 User Manual
Cornelius Ice Maker P N 629088662 User Manual
Craftsman Chainsaw 316350840 User Manual
Dynex CRT Television DX 15E220A12 User Manual
FEIN Power Tools Sander RS 12 70E User Manual
Fisher Price Baby Accessories P0278 User Manual
Frigidaire Air Conditioner FRA126CT1 User Manual
Gitzo Camcorder Accessories G1098 User Manual
Global Machinery Company Air Compressor DTC32L User Manual