Cooper Lighting Indoor Furnishings 132T8 User Manual

®
COOPER LIGHTING - METALUX  
DESCRIPTION  
Type  
The accord(TM) redefines fluorescent lighting by improving on aesthetics,  
comfort and energy savings. The accord(TM) provides the right amount of  
light while eliminating surface shadows commonly found in parabolics.  
Therefore, accord(TM) increases the comfort level while providing  
significant energy savings.  
Catalog #  
Project  
Date  
Comments  
Prepared by  
The accord(TM) is the ideal solution for offices, schools, hospitals, retail and  
other applications.  
SPECIFICATION FEATURES  
A ... Construction  
C ... Ballast Access  
E ... Reflectors  
Shallow 3-1/4" deep housing is die  
formed of code gauge, prime cold  
rolled steel. Heavy gauge end  
plates are securely attached with  
screws for strength and rigidity  
and the elimination of gaps. Four  
auxiliary fixture end suspension  
points are provided. Large access  
plate for supply connection.  
Ballast is mounted on a heavy  
gauge access plate and can be  
accessed from above the ceiling  
line.  
Reflector has high reflectance  
baked matte white enamel finish  
for luminous uniformity.  
F ... Shielding  
D ... Finish  
Positively retained frosted acrylic  
profile lenses provide a soft but  
effective distribution of light.  
Durable cold rolled steel with  
multistage, iron phosphate  
pretreatment and white enamel  
finish to ensure maximum bonding  
and rust inhibition.  
B ... Electrical*  
Ballasts are Class "P" and are  
positively secured. Rotor-lock  
lampholders ensure positive lamp  
retention. UL/CUL listed. Suitable  
for damp locations.  
AC  
132T8  
T8 LAMP  
1' X 4' Recessed  
Troffer Series  
A
F
D
E
B C  
MOUNTING DATA  
3-5/8"  
[93mm]  
11-3/4" [299mm]  
MOUNTING DATA  
LAMP CONFIGURATIONS  
6"  
Y
ENERGY DATA  
Input Watts:  
[153mm]  
X
EB Ballast & STD Lamps @ 277V  
132T8 (30)  
11-3/4"  
[299mm]  
Luminaire Efficacy Rating  
LER =FL75  
Catalog Number: AC-132  
48-3/8" [1229mm]  
Yearly Cost of 1000 lumens,  
3000 hrs at .08 KWH = $5.01  
CEILING COMPATIBILITY  
*Reference the lamp/ballast data in the  
Technical Section for specific lamp/ballast  
requirements.  
G
F
Ceiling  
Type**  
Exposed Grid  
ConcealedT  
Slot Grid  
Trim  
Type  
G
G or T  
G or T  
***  
**Consult Pre SalesTechnical Support.  
***See Drywall Frame Kit Accessory  
Grid/Lay-in  
Standard  
Drywall Frame  
Kit  
Flange  
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING  
TO LOCAL, STATE OR FEDERAL LAWS  
Safe and convenient means of  
disconnecting power  
Specifications and Dimensions subject to change without notice.  
ADF080357  
08/26/2008 2:44:34 PM  
Consult your representative for additional options and finishes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AC  
PHOTOMETRICS  
Candlepower  
AC-132  
Electronic Ballast  
Angle  
0
5
Along II  
798  
794  
783  
764  
738  
705  
665  
620  
570  
516  
458  
398  
337  
273  
207  
142  
81  
45°  
798  
796  
789  
777  
760  
739  
713  
682  
647  
606  
560  
507  
448  
383  
296  
192  
102  
31  
Across  
798  
797  
795  
790  
783  
771  
755  
735  
708  
675  
634  
584  
517  
403  
276  
171  
89  
(1) F32WT8/835 Lamp  
2850 Lumens each  
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Spacing criterion:  
(II) 1.2 x mounting  
height, ( ) 1.4 x  
mounting height  
||  
Efficiency 89.8%  
Test Report:  
AC-132.IES  
LER = FL75 LPW  
Yearly Cost of 1000  
lumens, 3000 hrs at  
.08 KWH = $5.01  
31  
0
22  
0
0
Coefficients of Utilization  
Effective floor cavity reflectance  
20%  
rc  
rw  
RCR  
0
1
2
3
4
5
6
80%  
70 50 30 10  
70%  
70 50 30 10  
50%  
50 30 10  
30%  
50 30 10  
10%  
50 30 10  
0%  
0
107 107 107 107  
97 93 89 86  
88 81 74 69  
80 70 63 57  
73 62 54 48  
67 55 47 41  
62 49 41 35  
57 45 37 31  
53 41 33 27  
50 37 30 25  
46 34 27 22  
104 104 104 104  
95 91 87 84  
86 79 73 68  
78 69 62 56  
71 61 53 47  
65 54 46 40  
60 49 41 35  
56 44 36 31  
52 40 33 27  
48 37 29 25  
45 34 27 22  
100 100 100  
87 84 82  
76 71 67  
66 60 55  
58 52 47  
52 45 40  
47 40 35  
43 36 31  
39 32 27  
36 29 24  
33 26 22  
96 96 96  
84 81 79  
73 69 65  
64 59 54  
56 51 46  
50 44 40  
45 39 34  
41 35 30  
38 31 27  
35 29 24  
32 26 22  
92 92 92  
80 78 77  
70 67 64  
61 57 53  
54 49 45  
49 43 39  
44 38 34  
40 34 30  
37 31 27  
34 28 24  
31 26 22  
90  
75  
62  
51  
43  
37  
32  
28  
25  
22  
20  
7
8
9
10  
Zonal Lumen Summary  
Luminance Data  
Average  
Average  
Average  
90-Deg  
cd/sm  
2568  
2739  
2565  
1777  
679  
Angle  
0-Deg  
cd/sm  
45-Deg  
cd/sm  
Zone  
0-30  
0-40  
0-60  
0-90  
0-180  
Lumens %Lamp  
%Fixture  
24.9  
in Deg  
636  
1062  
1974  
2559  
2559  
22.3  
37.3  
69.2  
89.8  
89.8  
45  
55  
65  
75  
85  
1963  
1867  
1738  
1476  
957  
2305  
2378  
2438  
1996  
957  
41.5  
77.1  
100.0  
100.0  
ORDERING INFORMATION  
SAMPLE NUMBER: AC-132-UNV-EB81-U  
Number of Lamps  
Shielding  
Blank=Frosted Acrylic  
(standard)  
Lamps  
BallastType  
EB8 =T8 Electronic Instant Start.  
Total Harmonic Distortion < 10%  
No. of Ballast  
1 or 2  
EB8 /PLUS=T8 Electronic Instant Start.  
Packaging  
Rating  
Blank=  
(Not included)  
L8835=T8 Lamp,  
17W and 32W,  
3500K  
L8841=T8 Lamp,  
17W and 32W,  
4100K  
L8835HL=T8  
Lamp, 32W,  
3500K, 3100  
Lumens  
L8841HL=T8  
Lamp, 32W,  
4100K, 3100  
Lumens  
U=Unit Pack  
PALC=Job Pack,  
in carton  
1=1 Lamp  
Standard  
NY=NewYork  
Rated  
ATW-SW4=  
Chicago  
Rated  
Voltage(1)  
UNV=Universal Voltage  
120-277  
Wattage (Length)  
32=32WT8 (48")  
High Ballast Factor >1.13.Total  
Harmonic Distortion < 20%  
No. of  
Ballast  
1 or 2  
Options  
Width(2)  
Blank=1' Width  
GL=Single Element Fuse  
GM=Double Element Fuse  
Flex=Flex installed  
ER8 =T8 Electronic Program Start.  
Total Harmonic Distortion < 10%  
No. of Ballast  
1 or 2  
Series  
AC=Accord Series  
EL=Emergency Installed  
HPT8 Ballast  
Ballast  
NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) 1' x 4' Accord is not designed for  
continuous row mount applications.  
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77  
HB8 =T8 Electronic Instant Start. Ballast Factor .88  
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0  
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2  
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without  
notice. Consult your Cooper Lighting Representative for availability and ordering information.  
HR8_DIM =T8 Electronic Program Start Step Dimming. Ballast Factor .88  
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77  
HR8 =T8 Electronic Program Start. Ballast Factor .88  
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2  
SHIPPING INFORMATION  
Catalog No.  
Wt.  
AC-132T8  
22 lbs.  
Specifications and Dimensions subject to change without notice.  
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801  
ADF080357  
08/26/2008 2:44:34 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Craftsman Lawn Mower 917253724 User Manual
Craftsman Lawn Mower 917389053 User Manual
Craftsman Lawn Mower Accessory 358792440 User Manual
Crosley Washer 134894000A User Manual
Cuisinart Coffeemaker DGB625BCU User Manual
Dynex CRT Television DX 32E250A12 User Manual
Elation Professional Home Safety Product 100WW User Manual
Exido Styling Iron 235 008 User Manual
GE Dishwasher gdt510 540 User Manual
Global Machinery Company Tiller DEC003AC User Manual