Read
Cooper Bussmann
BU-905U-L-R Receiver
Quick Start Guide
Version 1.8
and Retain
for Future
Reference
3A1578Rev1.8
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooper Bussmann BU-905U-L-R Receiver Quick Start Guide
Unit Components and Connections
Your BU-905U-L-R receiver unit has the following components and terminal connections:
IMPORTANT ELECTRICAL SAFETY INFORMATION
In order to comply with Electrical Safety Regulations, this module must be installed in an Electrical AND Fire enclosure. This enclosure may be a
single or multiple enclosures. Access to the module is to be made by a Service Person only.
In order to comply with Electrical Safety Standards, when connecting SELV AND voltages which are greater than SELV (30Vac or 60Vdc) together,
then Relay Output 2 must NOT be used in order to provide sufficient isolation between the outputs
3A1578Rev1.8
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooper Bussmann BU-905U-L-R Receiver Quick Start Guide
Front Panel Components
SMA Antenna Connector at Top of Unit
Indicator LEDs
RS232 Configuration Port
RSSI Push-Button
The LEDs on the front panel indicate the unit status:
LED Status
None
Indicates
No power supply.
OK LED Green
OK LED Red
RX LED Flashes
CF LED ON
PG LED on
Current status of the unit OK.
Fault condition detected in unit.
Receiving Message.
Module Communication Failure Output is active.
Configuration Cable Connected.
The Output LEDS (i.e., D1, D2, D3) light when the corresponding output is active.
Output LED ON
D1
D2
D3
Relay output D1 is ON (Contact Closed).
Relay Output D2 is ON.
Relay Output D3 is ON.
LEDs with RSSI Push
Button Pressed
When you press the RSSI push button, the unit shows the signal strength by lighting the LEDs
from the bottom to the top. Signal strength is the strength of the last message received that
was addressed to this station.
LED Signal Strength
LED Signal Strength
D1
D2
D3
More than -85 dBm
More than -90 dBm
More than -95 dBm
RX
CF
PG
More than -100 dBm
More than -105 dBm
Always on during RSSI test
Output LED flashing
quickly
If an output is in communication failure, the corresponding LED flashes at 5Hz.
D1
D2
D3
PG
Relay Output D1 is in communication failure.
Relay Output D2 is in communication failure.
Relay Output D3 is in communication failure.
Analog output is in communications failure.
4
3A1578Rev1.8
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooper Bussmann BU-905U-L-R Receiver Quick Start Guide
Antenna Installation
Resetting Your Unit to Factory Defaults
You must reset the receiver unit to factory defaults before linking the transmitter and receiver units.
To reset the default factory configuration:
1. Press and hold the RSSI push button.
2. Power on the BU-905U-L-R receiver.
3. The BU-905U-L-R receiver flashes all LEDs at medium flash (i.e., 1.6Hz).
NOTE: If the LEDs do not flash, you must repeat steps 1 and 2 until the LEDs flash before continuing.
4. Release the RSSI push button within 5 seconds.
5. Within a further 60 seconds, press and hold the RSSI push button for 5 seconds (until the LEDs stop flashing) and then release.
6. The BU-905U-L-R receiver lights all LEDs for 2 seconds before returning to normal operation.
NOTE: If the LEDs do not light, you must repeat the process from step 1 until the LEDs light before continuing.
7. You can now link the transmitter and receiver units.
3A1578Rev1.8
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooper Bussmann BU-905U-L-R Receiver Quick Start Guide
Linking Your Transmitter and Receiver Units
You must reset the transmitter unit to factory defaults (to disable encryption) before linking the transmitter and receiver units.
For more information, see the BU-905U-L-T Transmitter Quick Start Guide.
NOTE: You must complete the linking process in 60 seconds.
To link the transmitter and receiver units:
1. Press and hold down the RSSI Pushbutton on the receiver.
2. Power on the receiver while holding down the RSSI Pushbutton
3. Release the RSSI Pushbutton as soon as the Receiver LEDS flash (within 5 seconds of powering the receiver).
4. The receiver will flash all LEDs for a maximum 60 seconds while it tries to link to the transmitter.
5. Power on the transmitter. The transmitter sends a special “Link” message to allow the receiver to recognize the transmitter.
6. When the units link, the receiver lights all LEDs for 2 seconds before returning to normal operation.
NOTE: If the receiver LEDs continue flashing within the 60 seconds, the units are not linked and you should retry the linking process by powering
the transmitter off and on again. If you exceed the 60 seconds, you must restart the linking process from step 1.
7. You can now bench test your configuration before deploying.
Safety information
Thank you for selecting the BU-905U-L-R receiver for your telemetry needs. We trust it will give you many years of valuable service. To ensure
your BU-905U-L-R receiver enjoys a long life, double-check ALL your connections with the user’s manual before powering on the unit.
WARNING: Incorrect termination of supply wires may cause internal damage and will void warranty.
Exposure to RF energy is an important safety consideration. The FCC has adopted a safety standard for human exposure to radio frequency
electromagnetic energy emitted by FCC regulated equipment as a result of its actions in Docket 93-62 and OET Bulletin 65 Edition 97-01.
FCC Notice When Used in USA: BU-905U-L Wireless I/O Module
Part
Additional information
15
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC
rules (Code of Federal Regulations 47CFR Part 15). Operation is subject to the condition that this device does not cause
harmful interference.
90
This device has been type accepted for operation by the FCC in accordance with Part90 of the FCC rules (47CFR Part 90).
See the label on the unit for the specific FCC ID and any other certification designations.
Industry Canada: BU-905U-L Wireless I/O Module
RSS-119 - This device has been type accepted for operation by Industry Canada in accordance with RSS-119 of the Industry Canada rules. See
the label on the unit for the specific Industry Canada certification number and any other certification designations.
NOTE: Any changes or modifications not expressly approved by Cooper Bussmann P/L could void the user’s authority to operate this equipment.
To operate this equipment legally the user must obtain a radio-operating license from the government agency. This is done so the government can
coordinate radio users in order to minimize interference.
Safety Information - FCC Notice
This device complies with Part 15.247 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference; and
• This device must accept any interference received, including interference that may cause undesired operation
NOTE: This equipment is suitable for use in Class 1 Division 2 groups A, B and C or non-hazardous locations only.
6
3A1578Rev1.8
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooper Bussmann BU-905U-L-R Receiver Quick Start Guide
Unit Specifications
Input/Output
Number
Additional Information
Digital Outputs
3
Voltage-free contacts rated at 250Vac 1A, 30Vdc 1A.
2 for digital inputs and 1 for setpoint.
Status Outputs
Analog Output
Power Supply
2
1
1
Separate System OK and communication failure output.
16-bit resolution, 0.1% accuracy, single-ended source output.
9-30Vdc 0.25 Amp CSA certified Class 2 power supply. For use in Class I Div 2
hazardous locations, the power supply must be approved for Class I Div 2 use.
WARNING: Explosion hazard - do not disconnect while circuit is live unless area
is known to be non-hazardous.
Radio Receiver
Frequency
1
High sensitivity FHSS UHF radio receiver.
Actual frequency range depends on country.
At BER 8%.
902 – 928MHz
-110 dBm
Sensitivity
Document Information
Quick Start Guide Cooper Bussmann BU-905U-L Wireless I/O Receiver Unit Version 1.8
Cooper Bussmann Contact Details
Telephone
Fax
636-527-1270
636-527-1607
E-mail
Website
3A1578Rev1.8
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer Assistance
Customer Satisfaction Team
Application Engineering
Available to answer questions regarding Cooper
Bussmann products & services Monday-Friday,
8:00 a.m. – 4:30 p.m. for all US time zones.
Contact:
Technical assistance is available to all customers.
Staffed by degreed engineers, this application support
is available Monday-Friday, 8:00 a.m. – 5:00 p.m. CT
Contact:
s Toll-free phone: 855-287-7626 (855-BUSSMANN)
s Toll-free fax: 800-544-2570
s E-mail: [email protected]
s Phone: 636-527-1270
s Fax: 636-527-1607
s E-mail: [email protected]
Emergency and After-Hours Orders
Online Resources
resources:
Next flight out or will call shipment for time-critical needs.
Customers pay only standard product price, rush freight
charges, & modest emergency service fee. Place these
orders through the Customer Satisfaction Team during
regular business hours. For after-hours, contact:
s Product search & cross-reference
s Product & technical materials
s Solutions centers for information on topical issues
including arc-flash, selective coordination &
short-circuit current rating
s Technical tools, like our arc-flash calculator
s Where to purchase Cooper Bussmann product
s Phone: 314-995-1342
3
C
– the Enhanced, Online Cooper Customer Center
Provides real time product availability, net pricing, order
status & shipment tracking across six Cooper divisions:
B-line, Bussmann, Crouse-Hinds, Lighting, Power
Systems & Wiring Devices. Available at:
Services
Cooper Bussmann Services team provides engineering
expertise in electrical system reviews, electrical safety
training & component testing for Agency compliance.
Contact:
s 877-995-5955 for log-in assistance
s Phone: 636-207-3294
s E-mail: [email protected]
Cooper Bussmann
St. Louis, MO 63178
855.287.7626 (855-BUSSMANN)
Your Authorized Cooper Bussmann Distributor is:
©2011 Cooper Bussmann
PDF Only
8
3A1578Rev1.8
Download from Www.Somanuals.com. All Manuals Search And Download.
|