QUICKSPECS
Overview
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
AT A GLANCE
• AlphaServer GS140 systems
feature mainframe-like
performance and capabilities, and
high-availability computing
through clustering
GS140 systems include:
• Processor module with two Alpha
microprocessors 21264 6/525-
MHz CPUs, each with 4-MB
backup cache or two 21264 6/700
MHz CPUs, each with 8-MB
backup cache
• System I/O module with 4 I/O
channels
• 4-GB memory
• UltraSCSI single-channel
StorageWorks Plug-in Unit
• 9.1-GB 3.5″ UltraSCSI system
disk drive
• 2-m SCSI cable, BN38C-02
• 600-MB CD-ROM drive,
controller, and cable
• 12-slot PCI Plug-in-Unit
• PCI 1-port UltraSCSI Single-
ended adapter
• 10/100 Mb Fast Ethernet network
interface card
• Two H7263-AC or H7263-AD non-
BBU capable 48 VDC power
regulators.
• 3-phase power subsystem with
power cord
• Shielded console cable for
connection to terminal
• Tru64™ UNIX or OpenVMS
Factory Installed Software
• 90-day software product warranty
• Protected by Compaq Services,
including a one-year, on-site, four-
hour response hardware warranty;
system installation must be
ordered separately
1. CD-ROM with space for
optional diskette drive
2. Cabinet Control System
3. 9-Slot System Bus
(four front, five rear)
4. Power System
5. Cooling
6. Plug-In Units/ I/O or Disks or (two
front, two rear)
1
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Standard Features
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Intelligent Manageability
Software features for advanced server and network management, including
ServerWORKS™ Manager
ServerWORKS workgroup administrator
ServerWORKS Manager application
SNMP agents to manage SCO UNIX, Novell NetWare, and IBM OS/2
Intelligent Server Management
Security
Chassis lock
Multi-boot for choice of boot device
OS Support
Tru64 UNIX systems include pre-installed software, base license, unlimited user license, server extension
license, Open Source Internet Solutions, and Netscape Enterprise Server 3.0.
OpenVMS systems include pre-installed software, base license and Enterprise Integration Server License
Package V3.0A.
(Support is available for up to three instances of either Tru64 UNIX or OpenVMS on a single hardware platform)
Minimum OS support: Tru64 UNIX V4.0E or later or OpenVMS V7.1-2 or V7.2-1 or later
Service and Support
Protected by Compaq Services, including one-year, on-site hardware warranty with four-hour response.
Software warranty is a 90-day telephone advisory. Training, consulting, network integration, software support,
comprehensive system maintenance and guaranteed uptime services are also available for customers requiring
higher levels of service and support.
3
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Systems/Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 1 − Select system
GS140 systems require the mandatory selection of the following items:
•
•
•
Software media and documentation for first system on-site
Console terminal (unless available on site)
Installation or Installation and Startup Services
Notes: Minimum OS support: Tru64 UNIX V4.0E or later or OpenVMS V7.1-2 or V7.2-1 or later
For system integration of any options with 6-3 part numbers, contact CustomSystems
OS
CPUs
Memory UltraSCSI Disk UltraSCSI Adapter Ethernet Adapter
Order No.
Tru64 UNIX Two 6/525 MHz 4 GB
Tru64 UNIX Two 6/700 MHz 4 GB
OpenVMS Two 6/525 MHz 4 GB
OpenVMS Two 6/700 MHz 4 GB
9.1 GB
9.1 GB
9.1 GB
9.1 GB
KZPBA-CA
KZPBA-CA
KZPBA-CA
KZPBA-CA
DE500-BA or
3X-DE600-AA
DA-393GG-
AA/AB/AC
DE500-BA or
3X-DE600-AA
DA-394GG-
AA/AB/AC
DE500-BA or
3X-DE600-AA
DY-393GG-
AA/AB/AC
DE500-BA or
3X-DE600-AA
DY-394GG-
AA/AB/AC
Note: AA=60 Hz, 208V; AB=50 Hz, 416V; AC=50/60 Hz, 202V (Japan)
Step 2 − Additional CPU Modules (SMP Expansion) − Optional
•
•
•
Maximum of seven processor modules (14 CPUs)
All CPU modules must be at same speed on same bus.
For systems with more than three processor modules, a minimum of two memory modules is recommended for
optimal system performance
•
SMP license and end-user product warranty included
GS140 6/700 Tru64 UNIX SMP upgrade
GS140 6/700 OpenVMS SMP upgrade
GS140 6/525 Tru64 UNIX SMP upgrade
GS140 6/525 OpenVMS SMP upgrade
3X-764P2-AX
3X-764P1-AX
762P2-AX
762P1-AX
Step 3 − Memory − Optional
•
•
•
Maximum 28-GB memory, maximum of seven memory modules (maximum of seven memory modules is
reduced by one for each additional CPU module and System I/O module added).
Both 1-GB and 2-GB memory modules have built-in, 2-way interleaving; additional interleaving is
accomplished by adding more memory modules.
4-GB memory modules have built-in, 4-way interleaving; optimum performance is achieved when 2-GB
memory modules are paired with one 4-GB module or when one 4-GB memory module is paired with
another 4-GB module. Memory module sets (2 GB x 2 GB and 1 GB x 4 GB) or (2 GB x 4 GB) can be paired
with another 8-GB memory set for a maximum of 16-way memory interleaving.
4-GB memory module
2-GB memory module
1-GB memory module
MS7CC-GA
MS7CC-FA
MS7CC-EA
4
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 4 − I/O Expansion Buses − Optional
•
•
Systems include one PCI Plug-in Unit (PIU) DWLPB-AA, maximum two supported in system cabinet
Each DWLPB-AA PCI PIU includes 12-slot PCI bus and uses one rear expansion bay; StorageWorks BA670
PIU can occupy the corresponding front expansion bay.
•
Each DWLPB-AA PCI PIU has one open space for the addition of DWLPB-BA (second PCI expansion box) or
one BA671 Wide-UltraSCSI StorageWorks shelf
•
•
Each PCI Plug-in Unit requires one I/O channel connection to KFTHA-AA
Tru64 UNIX and OpenVMS systems support a maximum of 12 I/O channels with up to three KFTHAs
Note: DWLPAs are not supported on GS140 systems and upgrades.
PCI Plug-in-Unit with one PCI box for GS140 system cabinet only; requires one I/O channel
connection on KFTHA-AA, maximum two per system cabinet, two per system
Second PCI expansion box for mounting in DWLPB-AA; requires one I/O channel connection on
KFTHA-AA, maximum one per DWLPB-AA
Note: KFE70-AA and KFE72-EA are not supported concurrently on same system; however, either option can be
DWLPB-AA
DWLPB-BA
used to run RAID Configuration Utility (RCU).
UltraSCSI Single Channel StorageWorks Shelf (DS-BA356-LE) can be added to DWLPB-AA/AB in
place of second PCI expansion box (DWLPB-BA/BB); supports 16-bit (Wide) SCSI and some 8-bit
(Narrow) SCSI devices; maximum one per DWLPB-AA/AB, maximum six per system
UltraSCSI Dual Channel StorageWorks Shelf (DS-BA356-LF) can be added to DWLPB-AA/AB in
place of second PCI expansion box (DWLPB-BA/BB); supports 16-bit (Wide) SCSI and some 8-bit
(Narrow) SCSI devices; maximum one per DWLPB-AA/AB, maximum six per system
BA671-AA
BA671-AB
Step 5 − System I/O Modules − Optional
•
KFTHA-AA system I/O module included with systems; two additional KFTHA I/O modules can be added for a
system maximum of three; for multi-IOP support (up to three KFTHA-AA modules), GS140 6/525 system
must have at least one Rev D01 or later CPU module installed.
System I/O module with four I/O channels for PCI Plug-in Unit
KFTHA-AA
Step 6 − Storage Adapters/Controllers − Optional
•
Tru64 UNIX V4.0B without VGA support, or V4.0D or later with VGA, supports eight SCSI controllers per PCI,
maximum 64 per system.
•
•
OpenVMS V6.2-1H3 or later supports eight SCSI controllers per PCI, maximum 26 per system
For maximum controllers per PCI, required System Console Firmware Revision is 5.2-7 or later for 8400, or 5.3-
12 or later for GS140
•
•
•
•
•
PCI controllers can be added to all systems
Requires corresponding PCI Plug-in Unit (DWLPB-AA/AB/BA/BB)
System maximum of four KZPAC SCSI RAID controllers
Tape and optical devices are not supported on KZPAC SCSI RAID controllers.
Order Rear Door Expansion Kit, H9FDK-BA (top gun blue), for cable management on systems configured with
more than 12 SCSI controllers.
•
•
For cluster configurations, use Y cable (BN39A-0G) or SCSI Hub (BA35X-03/05)
DS-BA35X-DA UltraSCSI personality module required to connect DS-BA356-LE StorageWorks Shelf to a
KZPSA-BB or KZPBA-CB Differential SCSI adapter
•
•
•
OpenVMS V7.1-1H1 or later supports multi-host SCSI clusters
Manufacturing may substitute correct cable length depending on configuration
OpenVMS systems with greater than 1-GB memory require the following TIMA patch kits to support KZPAC
options: V6.2 kit-ALPDRIV04_062 and V7.1 kit-ALPDRIV01_071
5
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 6 − Storage Adapters/Controllers − Optional (continued)
Note: For installed systems that include KFTIA I/O modules, the KFTIA includes one single-ended port and three
fast wide differential ports for a total of four SCSI buses per module.
Maximum # Supported
Tru64 UNIX OpenVMS
PCI/System PCI/System
PCI Fibre Channel adapter (KGPSA-BC) (uses one PCI slot); Tru64
V4.0F and OpenVMS V7.2-1 support eight per system; requires Fibre
Channel cable; (SN-PBXNP-AC not currently supported in same
system under OpenVMS)
8/8
8/8
380574-001
234457-B2x
Fibre Channel cable (BNGBX-xx) xx=02, 05, 15, 30, 50 meters
x=1, 2, 3, 4, 5
PCI 1-port UltraSCSI single-ended adapter (uses one PCI slot)
PCI 1-port UltraSCSI differential host adapter (uses one PCI slot)
8/64
8/64
8/26
8/26
KZPBA-CA
KZPBA-CB
BN38C-01
1-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA-
Cx to BA670 in system cabinet (rear)
2-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA-
Cx to BA670 in system cabinet (front)
BN38C-02
BN38C-03
BN38C-05
3-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA to
I/O expansion cabinet
5-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA to
I/O expansion cabinet
PCI 1-port RAID (FWSE) controller (UltraSCSI-ready) with 4-MB cache
memory (uses one PCI slot); allows RAID levels 0, 0+1, 1, 5; includes
RAID Array 230/plus subsystem software and documentation kit; EISA
bridge option with floppy diskette drive required to run RCU; tape and
optical drives not supported; four per PCI, maximum of four per system
4/4
4/4
4/4
4/4
KZPAC-AA
KZPAC-CA
PCI 3-port RAID (FWSE) controller (UltraSCSI-ready) with 4-MB cache
memory (uses two PCI slots); allows RAID levels 0, 0+1, 1, 5; includes
RAID/Array 230/plus subsystem software and documentation kit; EISA
bridge option with floppy diskette drive required to run RCU; tape and
optical drives not supported; four per PCI, maximum of four per
system, requires BN31K-0E or KZPAC-SB for third-port connection
PCI 3-port RAID (FWSE) controller (UltraSCSI-ready) with 8-MB cache
memory (uses two PCI slots); allows RAID levels 0, 0+1, 1, 5; includes
RAID/Array 230/plus subsystem software and documentation kit; EISA
bridge option with floppy diskette drive required to run RCU; tape and
optical drives not supported; four per PCI, maximum four per system,
requires BN31K-0E or KZPAC-SB for third-port connection
4/4
4/4
KZPAC-CB
SCSI cable/bulkhead assembly kit with two ports for KZPAC-CA/CB,
allows connection of two third port outputs using one PCI bulkhead
slot.
KZPAC-SB
SCSI cable/bulkhead assembly kit with one port for KZPAC-CA/CB,
allows connection of one third port output using one PCI bulkhead slot
BN31K-0E
BN37A-01
BN37A-02
KZPSC-UB
MS100-BB
1-m VHDCI male-to-VHDCI male UltraSCSI cable, connects KZPAC to
front-mounted StorageWorks shelf.
2-m VHDCI male-to-VHDCI male UltraSCSI cable, connects KZPAC to
rear-mounted StorageWorks shelf.
Battery backup for cache memory option for KZPAC controller,
recommended for all KZPAC controllers
8-MB cache memory option; upgrades KZPAC-CA to KZPAC-CB, field
installable only
6
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 6 − Storage Adapters/Controllers − Optional (continued)
Maximum # Supported
Tru64 UNIX OpenVMS
PCI/System PCI/System
PCI Fast Wide Differential SCSI Adapter (uses one PCI slot); KZPSA
supports TruCluster Available Server and TruCluster Production
Server
SCSI-2 Fast Wide Differential cables; 68-pin male straight-to-68-pin male
right-angle; connects KZPSA-BB Fast Wide Differential SCSI-2 port to
DWZZA-VA or DWZZB-VW or connects to DOC-based BA356 via
BN38C cables to gain additional slot
Connects from KZPSA to DWZZB-VW in BA670-AB System cabinet
(rear);
connects from KZPSA to DWZZB-VW in BA671-AA in DWLPB-xx PIU
Connects from KZPSA to DWZZB-VW in BA670-AB System cabinet
(front)
8/64
8/26
KZPSA-BB
BN21K-xx
BN21K-01
BN21K-02
Connects from KZPSA to DWZZB-VW in BA670-AB Expansion cabinet
(front or rear)
BN21K-05/10
PCI DSSI adapter, 12 per PCI, (KFPSA and KFMSB not supported on
same DSSI bus)
-
-
12/24
4/26
KFPSA-AA
External shielded cable (MR/MR connectors); select required length, 09,
16, 25 feet
External shielded cable (MR/PS connectors); select required length, 06,
09, 16, 30 feet
BC29S-xx
BC29R-xx
PCI CI adapter, four per PCI, maximum 26 per system (uses one PCI slot
for adapter and one EISA slot for power only); Note: EISA Bridge
option not required
CIPCA-AA
Same as CIPCA-AA except uses 2 PCI slots
CIPCA-BA
BNCIA-xx
Computer interconnect cable sets, connects CIPCA to Star Coupler;
select length—10, 20, or 45 m
Step 7 − External Storage Controllers − Optional
•
HSZ70 UltraSCSI RAID Array controllers are supported under Tru64 UNIX V4.0B or later, OpenVMS V6.2-1H3
for direct attachments or OpenVMS V7.1-1H1 or later for cluster support.
•
HSZ80 UltraSCSI RAID Array controllers are supported under Tru64 UNIX V4.0E or later or OpenVMS V7.1-2
or later
•
•
HSG80 Fibre Channel controllers are supported under Tru64 UNIX V4.0F or OpenVMS V7.2-1 or later
HSJ50 family of CI Storage Array Controllers is supported under OpenVMS V6.2-1H3 with CIPCA-AA/BA or
CIXCD-AC CI controllers; QB-5C4AA-SA software kits are required for each external cache (one for HSJ50,
two for HSJ52, four for HSJ54).
•
•
Controllers require KZPSA, KZPBA, KFPSA, CIXCD or CIPCA SCSI adapters or controllers, as appropriate
HSZ70 requires QB-5SBAB-SA/SB for Tru64 UNIX, QB-5SBAC-SA/SB for OpenVMS
Fibre Channel controller (HSG80), includes 2-MB cache expandable to 128 MB and requires
128697-B21 HSG80 ACS V8.4F software kit or 128698-B21 V8.4P software kit for each
HSG80 ordered
UltraSCSI controller (HSZ80), includes 2-MB cache expandable to 32 MB and requires 400569-
001 for Tru64 UNIX or 400571-001 for OpenVMS
UltraSCSI controller (HSZ80), includes 2-MB cache expandable to 128 MB and requires 400569-
001 for Tru64 UNIX or 400571-001 for OpenVMS
StorageWorks UltraSCSI RAID Array controller, includes 64-MB cache expandable to 128 MB and
requires DS-HS35X-BC external cache battery and HSZ70 kit
32-MB cache 6-channel CI array controller with cache battery
128-MB cache 6-channel CI array controller with cache battery
Dual 64-MB cache CI array controller with cache batteries
Dual 128-MB cache CI array controller with cache batteries
Dual 256-MB cache CI array controller with cache batteries
Quad 512-MB cache CI array controller with cache batteries
380672-B21
400564-B21
400565-B21
DS-HSZ70-AH
HSJ50-AF
HSJ50-AJ
HSJ52-AF
HSJ52-AH
HSJ52-AJ
HSJ54-AJ
7
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 8 − Storage Devices − Optional
•
When multiple storage devices are configured with the system, specify which devices should be installed inside
system cabinet, inside system expansion cabinet, or installed in external StorageWorks cabinet. Line item
sequencing allows Manufacturing to configure storage options in the appropriate cabinet.
•
•
List storage options to be integrated in system cabinet immediately following the system part number.
List storage options to be integrated in StorageWorks cabinet immediately following StorageWorks cabinet part
number.
Internal Storage
•
•
•
System cabinet provides space for four disk Plug-in Units (PIU) if no PCI Plug-in Units are installed. Each of the
two pairs of expansion bays (front-to-back) in bottom of system cabinet can hold one Battery PIU, one PCI
PIU plus one SCSI disk PIU, one SCSI disk PIU, or two SCSI disk PIUs.
System cabinet provides space for up to seven StorageWorks shelves— three BA670-AB Plug-in Units (each
includes two StorageWorks shelves) and one BA671-AA StorageWorks shelf mounted in a DWLPB; each
shelf holds a maximum of two 5.25″ devices and one 3.5″ device or seven 3.5″ devices
UltraSCSI devices are supported in UltraSCSI StorageWorks PIUs and UltraSCSI StorageWorks shelves;
BA670-Ax and BA671-Ax support wide and narrow SCSI 5400 rpm, 7200 rpm, and 10,000 rpm disk drives
•
•
Order appropriate BN21*-** SCSI cables for connecting controllers and SCSI storage options.
Refer to the UltraSCSI Configuration Guidelines (EK-ULTRA-CG.C01)
UltraSCSI StorageWorks Plug-in Units
UltraSCSI single-channel StorageWorks Plug-in Unit, includes two DS-BA356-LE modular expansion
shelves, 16-bit single-ended I/O personality module (DS-BA35X-FA), single-channel I/O module,
48V 150W DC power supply, and GS140 mounting hardware; supports 16-bit wide SCSI devices
and some 8-bit narrow SCSI devices depending on compliance with minimum hardware revision
levels (included with base systems)
UltraSCSI dual-channel StorageWorks Plug-in Unit, includes two DS-BA356-LF modular expansion
shelves, 16-bit single-ended I/O personality module (DS-BA35X-FB), dual-channel I/O module,
48V 150W DC power supply, and GS140 mounting hardware; supports 16-bit wide SCSI devices
and some 8-bit narrow SCSI devices depending on compliance with minimum hardware revision
levels
BA670-AA
BA670-AB
UltraSCSI StorageWorks Shelves
UltraSCSI single-channel StorageWorks Shelf, includes 16-bit single-ended I/O personality module
(DS-BA35X-FA), single-channel I/O module, 48V 150W DC power supply, mounting hardware
and DS-BA356-LE.; can be added to DWLPB-AA/AB in place of second PCI expansion box
(DWLPB-BA/BB);
supports 16-bit (wide) SCSI and some 8-bit (narrow) SCSI devices; maximum one per DWLPB-
AA/AB; maximum six per system
UltraSCSI dual-channel StorageWorks Shelf, includes 16-bit single-ended I/O personality module
(DS-BA35X-FB), dual-channel I/O module, 48V 150W DC power supply, mounting hardware and
DS-BA356-LF.; can be added to DWLPB-AA/AB in place of second PCI expansion box (DWLPB-
BA/BB);
BA671-AA
BA671-AB
supports 16-bit (wide) SCSI and some 8-bit (narrow) SCSI devices; maximum one per DWLPB-
AA/AB; maximum six per system
SCSI Signal Converter
UltraSCSI-2 StorageWorks DOC Signal Converter, required to convert FWD signals from
KZPSA-BB or KZPBA-CB to single-ended for connection to DS-BA356-LE/LF StorageWorks
shelves, field installed only−DOC card installed in shelf does not utilize drive slot
Fast20 Personality Module for BA356 single-ended-to-single-ended 1-channel, field installed
only
Fast20 Personality Module for BA356 single-ended-to-single-ended 2-channel, field installed
only
Cable for above
DS-BA35X-DA
DS-BA35X-FA
DS-BA35X-FB
BN38C-02
8
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 8 − Storage Devices − Optional (continued)
UltraSCSI Hubs
UltraSCSI Hub with three differential ports (two host ports and one storage port), no single-
ended ports, in 3.5″ SBB, UltraSCSI cables not included
UltraSCSI Hub with five differential ports, no single-ended ports, consisting of four host ports and
one storage port in a 5.25″ SBB, UltraSCSI cables not included
UltraSCSI Hub with one differential port and two single-ended ports in 3.5″ SBB, UltraSCSI
DS-DWZZH-03
DS-DWZZH-05
DS-DWZZH-21
cables not included
16-bit Disk Drives
•
For 10,000 rpm drives, maximum six 18-GB or larger capacity drives when used in any BA356 blue shelf; 5.25”
devices not supported on same bus
Note: UltraSCSI disk drives run in Fast10 SCSI mode with KZPSA-BB PCI Fast Wide Differential SCSI adapters or
Fast20 mode with KZPBA or KZPAC adapters
36.4-GB 10,000 rpm 16-bit UltraSCSI disk drive SBB (not supported on KZPAC controllers)
18.2-GB 10,000 rpm 16-bit UltraSCSI disk drive SBB (not supported on KZPAC controllers)
18.2-GB 7200 rpm 16-bit UltraSCSI disk drive SBB (not supported on KZPAC controllers)
9.1-GB 10,000 rpm 16-bit UltraSCSI disk drive SBB
DS-RZ1FC-VW
DS-RZ1ED-VW
DS-RZ1EA-VW
DS-RZ1DD-VW
DS-RZ1DA-VW
9.1-GB 7200 rpm 16-bit UltraSCSI disk drive SBB
Tape Drives
•
Tape drives not supported with KZPAC RAID controller
8-GB DAT 3.5″ SCSI tape drive in StorageWorks carrier; requires OpenVMS V6.2-1H3 or later
or Tru64 UNIX V3.2C or later and System Console Firmware Revision 3.0-9
32/64-GB DAT tape loader in StorageWorks carrier
TLZ09-VA
TLZ9L-VA
DS-TLZ10-VA
TZ88N-VA
12/24-GB 4mm DAT SCSI tape drive in StorageWorks carrier
20/40-GB DLT SCSI tape drive in 5.25″ StorageWorks carrier
35/70-GB DLT SCSI tape drive in 5.25″ StorageWorks carrier
DS-TZ89N-VW
Solid State Disks
•
•
•
Supported with KZPBA and KZPSA adapters
Solid state disks cannot be combined with RZxx disks/tapes on same SCSI bus.
3.5″ and 5.25″ solid state disks not supported on same SCSI bus
1.6-GB Fast20 5.25″ Ultra solid state disk
1.1-GB Fast20 5.25″ Ultra solid state disk
536-MB Fast20 5.25″Ultra solid state disk
268-MB Fast20 3.5″ Ultra solid state disk
134-MB Fast20 3.5″ Ultra solid state disk
DS-EZ716-VW
DS-EZ711-VW
DS-EZ705-VW
DS-EZ42-VW
DS-EZ41-VW
RAID Storage Solutions
•
•
•
ESA 12000 Storage Arrays and RAID Array 8000 (HSG80/HSZ80) product sets are supported on Tru64 UNIX
and OpenVMS systems.
ESA 10000 Storage Arrays and RAID Array 7000 (HSZ70) product set are supported on Tru64 UNIX and
OpenVMS systems.
Ordering and configuring information is available at www.compaq.com/products/storageworks
9
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 8 − Storage Devices − Optional (continued)
External Storage Devices
The following devices can be added as required:
SW5XX, SW6XX, SW8XX Storage Cabinets
SCSI Disk Drives
Tape Drives −TZ87, TZ857(loader support for Tru64 UNIX available via DECnsr), TZ877, TZ88, TZ885, TZ887,
TSZ07, TLZ09, TKZ9E, TKZ9F, TLZ9L, TKZ6x, TL810, TL812, TL820, TL822, TL826, DS-TL891-NE/NT, DS-
TL892-UA, DS-TL893-BA/AC, DS-TL894-BA, DS-TL896-BA, DS-TLZ10-VA, DS-TL895-xx, TZK10/12/20
Step 9 −Networks and Communications −Optional
•
Connection of system to Ethernet requires twisted-pair cable (except when using DE500-FA).
Note: For installed systems with KFTIA I/O modules, KFTIA includes two 802.3/Ethernet ports per module.
PCI LAN Communications Controllers
•
•
•
Requires DWLPB-xx PCI shelf mount box (one included)
Maximum six DEFPA-AB/DB/UB/MB FDDIcontrollers (100 Mb/sec) per system
Each adapter/controller uses one PCI slot
Maximum # Supported
Tru64 UNIX OpenVMS
PCI/System PCI/System
PCI 1-port 10/100-Mb Ethernet adapter (Twisted Pair); SN-PBXNP-AC
(Token Ring Adapter) not supported in same system; requires
NHD1 of Tru64 UNIX (UCX V4.2 TCP/IP Services Software not
recommended with DE60* devices; TCP/IP V5.0 is recommended)
8/8
8/8
8/8
-
3X-DE600-AA
3X-DE602-FA
MultiMode Fiber (MMF) add-on daughter card for use with the 3X-
DE602-AA; Tru64 UNIX NHD2 required
Category 5 cross-over cable for point-to-point, unshielded
Category 5 cross-over cable for point-to-point, shielded
Category 5 straight through for system to repeater or hub, unshielded
Twisted pair, shielded (-03, -04, -07 available lengths)
BN24Q-xx
BN28Q-03
BN25G-xx
BN26M-xx
Universal PCI to FDDI controller Fibre−Single Attachment Station
(SAS) MultiMode Fibre with SC; requires BN34x SC type
connecting cable
6
6
6
6
3X-DEFPA-AC
3X-DEFPA-DC
Universal PCI to FDDI controller Fibre−Dual Attachment Station (DAS)
MultiMode Fibre with SC; requires BN34x SC type connecting
cable
MultiMode Fibre Optic Duplex cable; SC connector-to-ST connector
MultiMode Fibre Optic Duplex cable; SC connector-to-SC connector
MultiMode Fibre Optic Duplex cable; SC connector-to-MIC connector
BN34A-xx
BN34B-xx
BN34D-xx
Universal PCI to FDDI controller, copper−Dual Attachment Station
(DAS) CAT 5 UTP with RJ; , requires BN26x or BN25H connecting
cables
6
6
6
6
3X-DEFPA-
MC
Universal PCI to FDDI controller Copper−Single Attachment Station
(SAS) CAT 5 UTP with RJ; requires BN26x or BN25H connecting
cables
3X-DEFPA-UC
8-pin MP-to-8-pin MP, screened, EIA/TIA category 5 cable
8-pin MP-to-8-pin MP, screened, crossover, EIA/TIA category 5 cable
3-m unshielded twisted pair RJ45 connectors
BN26M-xx
BN26S-xx
BN25H-03
PCI Gigabit Ethernet adapter, does not support network boot; one per
DWLPB
4
4
DEGPA-SA
10
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 9 −Networks and Communications −Optional (continued)
Maximum # Supported
Tru64 UNIX OpenVMS
PCI/System PCI/System
PCI-to-ATMworks 155 Mb fibre adapter; Tru64 UNIX and appropriate
patch kits (patch kit 1 for V4.0F; patch kit 2 for V4.0E, patch kit 4
availability; SN-PBXNP-AC PCI Token Ring adapter not
6
-
3X-DAPBA-FA
supported in same system with ATM 155 (DAPBA) adapter; if
ATMworks 351 (DGLPA) NIC card is installed, follow that
adapter’s configuration rules; only one ATM adapter can be
installed on same bus as ATMworks 351 network interface card.
Same as above except UTP
3X-DAPBA-UA
3X-DAPCA-FA
PCI-to-ATMworks 622 Mb fibre adapter; Tru64 UNIX and appropriate
patch kits (patch kit 1 for V4.0F; patch kit 2 for V4.0E, patch kit 4
availability; SN-PBXNP-AC PCI Token Ring adapter not
2
-
supported in same system with ATM 622 (DAPCA) adapter; if
ATMworks 351 (DGLPA) NIC card is installed, follow that
adapter’s configuration rules; only one ATM adapter can be
installed on same bus as ATMworks 351 network interface card.
PCI Asynchronous 4-port adapter, maximum two PBXDA-xx per
system
2/2
2/2
2/2
-
2/2
2/2
2/2
2/2
2/2
PBXDA-AA
PBXDA-AB
PBXDA-AC
PBXDP-AA
PBXDP-AB
PCI Asynchronous 8-port adapter, maximum two PBXDA-xx per
system
PCI Asynchronous 16-port adapter, maximum two PBXDA-xx per
system
PCI Synchronous 2-port controller, two PBXDP-xx per system
(requires OpenVMS V7.1-2 or later support at this time)
PCI Synchronous 4-port controller, two PBXDP-xx per system
(requires OpenVMS V7.1-2 or later support at this time)
-
Step 10 −MEMORY CHANNEL −Optional
•
MEMORY CHANNEL options are supported on GS140 with Console Firmware V5.3-12 or later and 8400
systems with Console Firmware V5.4-10 or later; Console Firmware is available on CD-ROM (AG-RFCBB-
•
Two PCI System Area Network controllers supported per system
Tru64 UNIX Systems
•
•
MEMORY CHANNEL options require Tru64 UNIX V4.0F with TruCluster V1.6 or later
Each system node in a MEMORY CHANNEL cluster requires a TruCuster Production Server (QB-3RLAQ-KA)
or TruCluster MEMORY CHANNEL (QB-4ZCAQ-AA) software license
•
•
TruCluster MEMORY CHANNEL license (QB-4ZCAQ-AA), normally used for high- performance technical
computing applications, is not required if systems include a TruCluster Production Server license (QB-
3RLAQ-KA)
The following options are not currently supported with MEMORY CHANNEL: DJ-ML200, CIPCA
OpenVMS Systems
•
•
•
•
•
MEMORY CHANNEL options require OpenVMS V7.1-2 or later and OpenVMS Cluster license (QL-MUZAQ-
AA)
Two-node clusters can be configured by ordering a CCMAB-AA for each system and 1 BN39B-04 or BN39B-10
cable, cable connects directly to CCMAB-AA in each system
For three or four system clusters, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for
each system and one CCMHB-AA hub for the cluster
CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system
nodes can be achieved by adding up to four additional CCMLB-AA line cards
If two or more CCMAB-AA controllers are configured in each system, a second CCMHB-AA hub is required for
clusters with more than two nodes; in two-node clusters the CCMAB-AA may be directly connected.
11
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 10 −MEMORY CHANNEL −Optional (continued)
OpenVMS Systems (continued)
•
In cases where nodes must be separated by a longer distance than standard copper cables allow, the CCMFB
option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fibre optic
cable. The fibre optic connection may be up to 2,000 meters long between two CCMAB controllers connected
in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from
the CCMHB hub to a second system may also be 3,000 meters). The CCMFB option requires a second PCI
slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB
controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a
slot normally used by the CCMLB line card, limiting expansion to four radial fibre optic connections.
•
The CCMHB-BA hub expansion box provides additional slots for up to 8 fibre optic connections. Two standard
length, single-mode fibre optic cables are available (BN34R-10 and BN34R-31); however, users normally
provide this connection. Customers should reference the TIA/EIA 568-A Commercial Building
Telecommunications Cabling Standard, Section 12.3.4. Fibre optic connectivity is completely transparent to
the systems using it and has no performance impact.
MEMORY CHANNEL Controller/Network Hub
PCI System Area Network controller, maximum two
CCMAB-AA
CCMHB-AA
System Area Network hub with 4 line cards; includes BN19P-2E power cord for Canada, Japan,
and US operations; country-specific power cord for other regions is required
MEMORY CHANNEL hub expansion box with no line cards
Expansion line card for CCMHB hub
CCMHB-BA
CCMLB-AA
BN39B-01
1-m cable for CCMAB and CCMHB
4-m cable for CCMAB and CCMHB
BN39B-04
10-m cable for CCMAB and CCMHB
BN39B-10
Copper-to-single mode fibre optic converter
TruCluster Production Server Software for Tru64 UNIX
Tru64 UNIX Driver for MEMORY CHANNEL license
OpenVMS Cluster license for Alpha systems
CCMFB-AA
QB-3RLAQ-AA
QB-4ZCAQ-AA
QL-MUZAQ-AA
MEMORY CHANNEL Power Cords
Ireland, United Kingdom
Egypt, India
BN19A-2E
BN19S-2E
BN19C-2E
BN18L-2E
BN19E-2E
BN19M-2E
BN19K-2E
BN19H-2E
Central Europe
Israel
Switzerland
Italy
Denmark
Australia, New Zealand
MEMORY CHANNEL (Requirements for Currently Installed AlphaServer 8400 systems)
•
•
Console firmware at revision V2.3 or higher
CCMAA-BA adapter must be installed in slots 0-7 of a DWLPA-AA/AB/BA/BB PCI; no restriction for
DWLPB-AA/AB/BA/BB PCI bus
•
•
For two system nodes, order one CCMAA-BA per system and one BC12N-10 cable to connect them.
For three or more system nodes, order CCMHA-AA (MEMORY CHANNEL Hub) one CCMAA-BA and one
BC12N-10 cable per system node.
•
CCMHA-AA (MEMORY CHANNEL Hub) is configured with four CCMLA-AA Line Cards and supports up to four
nodes. Expansion up to eight system nodes can be achieved by adding up to four additional CCMLA-AA Line
Cards, except TruCluster Production Server configurations
PCI to MEMORY CHANNEL controller, maximum two
CCMAA-BA
CCMHA-AA
CCMLA-AA
MEMORY CHANNEL Hub with four line cards
MEMORY CHANNEL Line Card for use with MEMORY CHANNEL Hub (CCMHA-AA)
12
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 10 −MEMORY CHANNEL −Optional (continued)
MEMORY CHANNEL (Requirements for Currently Installed AlphaServer 8400 systems) (continued)
MEMORY CHANNEL cable
BC12N-10
QB-3RLAQ-AA
QB-4ZCAQ-AA
QL-MUZAQ-AA
TruCluster Production Server Software for Tru64 UNIX
Tru64 UNIX Driver for MEMORY CHANNEL license
OpenVMS Cluster license for Alpha systems
CCMHA-AA, MEMORY CHANNEL Hub, includes BN19P-2E line cord for Canada, Japan, and U.S. operation. For
other regions, order power cords listed above.
Step 11 −Console Terminal −Required unless terminal is available onsite.
•
VT console terminal with EIA-232 25-pin DSUB connector is required, (even with KFE72 installed) for system
power-up, diagnostics and console display; order unless otherwise available.
•
Shielded console cable is included for connection to console terminal.
VT510 terminal
VT510-xx
Step 12 −Graphics Support for Tru64 UNIX − Optional
•
Graphics support for GS140 and 8400 running Tru64 UNIX V4.0D or later can be provided through the
combined use of KFE72-EA port option and the SN-PBXGB-TL graphics adapter.
•
SN-PBXGB-TL requires 17″ or 21″ Professional Series monitor and keyboard for graphics support unless
available onsite
•
•
Selection of video extension cable and country-specific power cord required for all monitor variants
EISA or ISA options are not supported on KFE72-EA subsytem
Graphics console subsystem for Tru64 UNIX systems, includes diskette drive and mouse; KFE70-
AA and KFE72-EA are not supported concurrently on the same system; however, either option
can be used to run RAID Configuration Utility (RCU).
KFE72-EA
GSxxx/8400 graphics adapter
SN-PBXGB-TL
Step 13 −Tru64 UNIX and OpenVMS Partitions −Optional
•
A single GS140 can be divided into a maximum of three logical hardware partitions. Each partition is allocated
its own set of hardware resources− CPU, memory, I/O module. Partitioning support requiresTru64 UNIX
V4.0F or later, or OpenVMS V7.2 or later operating system and partitioning licenses.
•
•
System Console Firmware Revision 5.4 or later required
Each partition requires a minimum of one CPU module, one memory module, one I/O module, and one DWLPB
(PCI and PIU shelf) per partition.
•
Each partition must have a dedicated console terminal. The first partition will obtain this support in a standard
manner via the server console panel. The second and third partition requires a KFE72-DA to obtain this
console support. H8571-J adapter is required to connect KFE72-DA to the console terminal;
KFE72-DA does not include a diskette drive, which is required to support RAID Configuration Utility (RCU).
Order KFE72-EA if a floppy or graphic support is required.
•
For more information regarding Tru64 UNIX V4.0F partitioning configuration hardware guidelines and console
partition commands, see Tru64 UNIX V4.0F SPD 41.61.22 and Tru64 UNIX V4.0F System Administration
Guide, Appendix E.4.
•
•
For more information regarding OpenVMS Galaxy partitioning guidelines and support, see
http://www.openvms.digital.com/availability/GALAXY.HTML
Existing AlphaServer 8400 users can upgrade their system to an AlphaServer GS140 level system that
supports hardware partitions with a CPU upgrade (dual Alpha 21264 6/525 or 6/700 MHz CPU modules),
Operating System upgrade (Tru64 UNIX V4.0F), and System Console Firmware Revision 5.4 or later;
additional hardware may be required to support hardware partitions.
13
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 13 −Tru64 UNIX and OpenVMS Partitions −Optional (continued)
Minimum Hardware Required per GS140 Partition
•
Dual Alpha 21264 6/525-MHz CPU module (at least one Rev. D01 CPU Alpha 21264 module per system) or
dual Alpha 21264 6/700-MHz CPU module
•
•
•
•
•
•
MS7CC-EA/FA/GA memory module (1 GB, 2 GB, 4 GB)
KFTHA-AA or KFTIA-AA I/O module (KFTIA for installed base only)
DWLPB-xx PCI Plug-in Unit
KFE72-DA serial port console (used for second and third instance of Tru64 UNIX or OpenVMS Galaxy)
Console terminal with shielded console cable for each partition
CD-ROM reader (or network adapter) is required per partition; additional SCSI CD-ROMs can be configured in
StorageWorks shelf using supported I/O adapters
•
•
Tru64 UNIX Hardware Partition license per partition for second and third partition support (QM-MT4AA-AA)
OpenVMS software partition license required for each CPU in a partition (QL-66XAA-3B/3C/3D/3F)
Unsupported Options for GS140 Partitions
•
•
•
•
•
•
MEMORY CHANNEL; clustering of a partitioned GS140 is not supported
NVRAM (Prestoserve Non-Volatile Random Access Memory)
EISA devices
XMI is supported in first partition of GS140 only
Future Bus is not supported
Supported Options List (SOL) restriction rules still apply for maximum configurations of GS140 systems
Step 14 −Monitors −Optional
17″ (16″ viewable image size) professional series auto-scanning color monitor, Trinitron CRT,
0.25 mm aperture grill pitch, VGA to 1280 x 1024 at 75 Hz, TCO 95, MPR-II, Energy Star,
attached 1.8-m video cable; requires video extension cable and country-specific power cord;
Northern Hemisphere without power cord
3R-VRQP7-24
Same as above except Southern Hemisphere without power cord
3R -VRQP7-23
3R -VRQP1-24
21″ (19.6″ viewable image size) auto-scanning color monitor, Trinitron CRT, 0.25 mm aperture
grill pitch, VGA to 1600 x 1200 at 75 Hz NI, TCO 95, Energy Star, includes 1.8-m video cable;
requires video extension cable and country-specific power cord; Northern Hemisphere without
power cord
Same as above except Southern Hemisphere without power cord
3R -VRQP1-23
BN39C-02
Video Extension Cable
1.8-m video extension cable
Monitor Power Cords
North America, Japan
UK/Ireland/Hong Kong
Central Europe
Switzerland
BN26J-1K
BN19A-2E
BN19C-2E
BN19E-2E
BN19H-2E
BN19K-2E
BN18L-2E
BN19M-2E
BN19S-2E
3X-BN46F-02
Australia/New Zealand
Denmark
Israel
Italy
India/South Africa
Japan
14
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 15 −Keyboards −Selection of country-specific keyboard required.
Tru64 UNIX
OpenVMS
SN-LKQ47-AA LK461-A2
SN-LKQ47-AB LK461-AB
SN-LKQ47-AC LK461-AC
SN-LKQ47-AD LK461-AD
U.S./English keyboard
Belgian keyboard
Canadian/French keyboard
Danish keyboard
UK keyboard
SN-LKQ47-AE
SN-LKQ47-AF
-
Finnish keyboard
LK461-AF
German keyboard
Dutch keyboard
SN-LKQ47-AG LK461-AG
SN-LKQ47-AH LK461-AH
Italian keyboard
SN-LKQ47-AI
SN-LKQ47-AK LK461-AK
LK461-AL
LK461-AI
Swiss/French keyboard
Swiss/German keyboard
Swedish keyboard
Norwegian keyboard
French keyboard
-
SN-LKQ47-AM LK461-AM
SN-LKQ47-AN LK461-AN
SN-LKQ47-AP
-
LK461-AP
LK461-AQ
-
Canadian/English keyboard
Latin-American keyboard
Spanish keyboard
Hebrew keyboard
Portuguese keyboard
BHCSY keyboard
International keyboard
Greek keyboard
SN-LKQ47-AR
SN-LKQ47-AS
SN-LKQ47-AT
LK461-AS
LK461-AT
SN-LKQ47-AV LK461-AV
SN-LKQ47-AX
SN-LKQ47-BA
-
-
SN-LKQ47-BH LK461-BH
Taiwanese keyboard
Korean keyboard
SN-LKQ47-BI
SN-LKQ47-BK
-
-
-
Romanian keyboard
Polish keyboard
LK461-BL
LK461-BP
SN-LKQ47-BP
Hungarian keyboard
Arabic keyboard
SN-LKQ47-BQ LK461-BQ
SN-LKQ47-BR
SN-LKQ47-BT
-
Cyrillic keyboard
LK461-BT
Turkish keyboard
SN-LKQ47-BU LK461-BU
SN-LKQ47-BV LK461-BV
Czech keyboard
Turkish/French keyboard
Yugoslavian keyboard
Thai keyboard
-
LK461-BW
-
LK461-BY
SN-LKQ47-CB
SN-LKQ47-CV
-
-
S. Chinese keyboard
Slovak keyboard
SN-LKQ47-CZ LK461-CZ
15
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 16 −Expansion: System Cabinet and I/O Expansion Cabinet −Optional
System Cabinet
•
Expanded Base System Cabinet includes two 3-phase power regulators with space for one additional 3-phase
power regulator. System cabinets shipped after June 1996 (H9F00-FC/FD/FE Rev B03 or later) include the
H7263-AC/AD non-battery backup ready power regulator.
•
•
Maximum four I/O channels per cabinet; PCI Plug-in Units require one I/O channel connection
Four lower expansion bays are available for Plug-in Units; the lower bays accommodate Plug-in Units as
follows:
- Disk Plug-in Unit (BA670-AA/AB), maximum of four, front or rear expansion bay
- Battery Plug-in Unit (H7237-AA/AC/CA/CB), maximum of one, front or rear expansion bay
- PCI Plug-in Unit (DWLPB-AA), maximum of two, rear expansion bay only
I/O Expansion Cabinet
•
I/O expansion cabinet includes one 3-phase power regulator, and provides space for two additional 3-phase
power regulators
•
•
H9F00-JC/JD/JE Rev C03 or later cabinets include H7263-AC or H7263-AD non-BBU capable power regulator
I/O Expansion cabinet can be configured to hold all disk Plug-in Units or combination of disk Plug-in Units and
PCI Plug-in Units
•
Six expansion bays – two upper and four lower – are available for Plug-in Units; the two upper bays
accommodate a maximum of two disk Plug-in Units; the four lower bays accommodate Plug-in Units as
follows:
- Upper bay – Disk Plug-in Unit (BA670-AA/AB, maximum two, front or rear expansion bay
- Lower bay – Disk Plug-in Unit (BA670-AA/AB), maximum four, front or rear expansion bay
- Lower bay – PCI Plug-in Unit (DWLPB-AB), maximum two, rear expansion bay only
- Lower bay – Battery Plug-in Unit (H7237-AA/AC/ CA/CB), maximum one, front or rear expansion bay
I/O expansion cabinet (top gun blue) 3-phase power, maximum two per system;
JC = 60 Hz, 208V, JD = 50 Hz, 380/416V, JE = 50/60 Hz, 202V
H9F00-
JC/JD/JE
PCI Plug-in Unit for GS140 and 8400 I/O expansion cabinet only, maximum two per cabinet;
maximum six DWLPB-AA and DWLPB-AB (PCI PIU) per system; requires one I/O channel
connection on KFTHA-AA
Second PCI expansion box for mounting in DWLPB-AB, maximum one per DWLPB-AB; requires
one I/O channel connection on KFTHA-AA
DWLPB-AB
DWLPB-BB
Step 17 −Power Expansion Components −Optional
•
System Cabinet and I/O Expansion Cabinets must be same type, either 3-phase or single-phase; mixing of 3-
phase and single-phase cabinets in same system configuration is not supported
•
•
Determine the need for adding third power regulator by filling in the EPU Power Configuration Table
Power Configuration Table provides a manual method for determining the need for a third power regulator.
Equivalent power unit (EPU) is an equivalent value of power used (48 VDC) by each option.
3-Phase Expansion Components
•
Select additional H7263-AC/AD for expansion cabinets that do not require battery backup option: If EPU value
of first regulator is exceeded, if N+1 redundancy is required, if third power regulator is required
•
Select H7237-CA/CB for systems that require battery backup (factory installed). It includes battery Plug-in Unit,
one H7263-AA/AB power regulator, and batteries for battery backup/UPS capability. It must be ordered at
time of system purchase if BBU functionality is required. H7263-AA/AB mounts alongside the standard
H7263-AC/AD. It provides eight minutes per regulator.
•
Select H7238-BA/BB for additional battery UPS (factory installed). Includes H7263-AA/AB and H7238-AA 4-
pack battery option for second and third regulator support
Battery option for I/O Expansion Cabinet, fully loaded battery cabinet supports three power regulators;
provides 16 minutes per regulator; maximum one per H9F00-BA/BB/BC expansion cabinet
H9B00-AF
Power Option for StorageWorks Shelves in StorageWorks Plug-in Units
•
Provides N+1 power for BA670-AB, BA671-AA StorageWorks PIUs/shelves; occupies one slot in StorageWorks
shelf
48 VDC 150W Redundant Enhanced Power Supply for BA670-AB, BA671-AA, includes 48 VDC jumper
cable for connecting to first power supply in StorageWorks shelf.
DS-
BA35X-HJ
16
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 18 −Software − Required selection of media and documentation for first system on
site
•
Software Processor Code = Q
Tru64 UNIX
Tru64 UNIX systems include Traditional Unlimited User License, Server Extension License, and Open Source
Internet Solutions.
•
Tru64 UNIX V4 media and online documentation on CD-ROM
Tru64 UNIX V4 full hard copy documentation
QA-MT4AA-H8
QA-MT4AA-GZ
QA-6ADAA-H8
QA-6ADAA-GZ
QB-5RXAQ-AA
Tru64 UNIX V5 media and online documentation on CD-ROM
Tru64 UNIX V5 full hard copy documentation
StorageWorks Software Package with licenses for Logical Storage Manager and AdvFS
Utilities
TruCluster Available Server V4 license and documentation
TruCluster Available Server V4 license
QB-05SAQ-AA
QL-05SAQ-AA
QL-5U29M-3D
QL-5U29M-3E
QL-5U29M-3F
QL-5U29M-3G
QL-5U29M-3H
QA-054AA-H8
QL-MTJAQ-AA
QL-MTKAQ-AA
Advanced Server for Tru64 UNIX, 25 Client Concurrent License
Advanced Server for Tru64 UNIX, 50 Client Concurrent License
Advanced Server for Tru64 UNIX, 100 Client Concurrent License
Advanced Server for Tru64 UNIX, 250 Client Concurrent License
Advanced Server for Tru64 UNIX, 500 Client Concurrent License
Layered products media and documentation for Tru64 UNIX on CD-ROM
DECnet/OSI end-system license
DECnet/OSI extended function license
OpenVMS
•
OpenVMS systems include OpenVMS Base license with system manager license and Compaq Enterprise
Integration Server License Package for OpenVMS Revision V3.0A.
•
Compaq Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows
Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint Supervisor for OpenVMS
Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management
Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk Services for Windows NT, Office Server for
OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS – Advanced Server, and DIGITAL Office
Server Client Access License.
•
•
OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified
number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be
moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and
OpenVMS Alpha cluster.
OpenVMS Traditional Unlimited Use license is system specific and can only be used on one single system at a
time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster.
Concurrent Use 1-user license
QL-MT3AA-3B
QL-MT3AA-3C
QL-MT3AA-3D
QL-MT3AA-3E
QL-MT3AA-3F
QL-MT3AA-3G
QL-MT3AA-3H
QL-MT3AA-3J
QL-MT3AA-3K
QL-MT2AQ-AA
QA-MT1AT-H8
QA-MT1AR-H8
QA-MT1AA-H8
QA-09SAA-GZ
Concurrent Use 2-user license
Concurrent Use 4-user license
Concurrent Use 8-user license
Concurrent Use 16-user license
Concurrent Use 32-user license
Concurrent Use 64-user license
Concurrent Use 128-user license
Concurrent Use 256-user license
Traditional unlimited user license
OpenVMS V7.2-1 media and online documentation on CD-ROM
OpenVMS V7.1-2 media and online documentation on CD-ROM
OpenVMS media and documentation on CD-ROM
OpenVMS base hard copy documentation
17
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 18 −Software − Required selection of media and documentation for first system on
site (continued)
OpenVMS
Layered products media and documentation for OpenVMS on
CD-ROM; includes Compaq Enterprise Integration Server for OpenVMS media and
documentation
QA-03XAA-H8
DECnet/OSI end-system license
QL-MTFAQ-AA
QL-MTHAQ-AA
QL-MUZAQ-AA
DECnet/OSI extended function license
Cluster License for OpenVMS Alpha
Step 19 −Hardware and Software Supplemental Support Services −Installation Services
required
Installation Services
•
Installation or Installation and Startup is mandatory for all GS140 systems. Consult a Compaq Customer
Service Account Representative for assistance in selecting the support plan that is most appropriate. For
more information on Compaq Services see: http://www.compaq.com/services
Hardware Supplemental Support − Americas and Asia Pacific only
•
Systems include one-year hardware warranty, on-site, same day, four-hour response time; select optional
Hardware Supplemental Support Services if required.
2 CPUs −
4 GB Memory
FM-8Z4HR-36
FM-8Z512-36
FM-8Z616-36
FM-8Z724-36
FM-8Z4HR-60
FM-8Z512-60
FM-8Z616-60
FM-8Z724-60
Years 1-3, 5 x 9, Four-hour response time
Years 1-3, 5 x 12, Four -hour response time
Years 1-3, 6 x 6, Four -hour response time
Years 1-3, 7 x 24, Four -hour response time
Years 1-5, 5 x 9, Four -hour response time
Years 1-5, 5 x 12, Four -hour response time
Years 1-5, 6 x 16, Four -hour response time
Years 1-5, 7 x 24, Four -hour response time
Software Supplemental Services − 2 CPU Systems
•
•
•
Systems include 90-day Conformance to SPD and Telephone Advisory Support. Select optional Software
Supplemental Support Services if required.
Software service upgrades for Tru64 UNIX include advisory and remedial software support with new version
license rights for Tru64 UNIX Base, unlimited users and Server Extensions.
Software service upgrades for OpenVMS include advisory and remedial software support with new version
license rights for OpenVMS Base and Enterprise Integration Package.
Tru64 UNIX
OpenVMS
12-month 5 x 9 Bronze Software Supplemental Support
36-month 5 x 9 Bronze Software Supplemental Support
60-month 5 x 9 Bronze Software Supplemental Support
12-month 7 x 24 Bronze Software Supplemental Support
36-month 7 x 24 Bronze Software Supplemental Support
60-month 7 x 24 Bronze Software Supplemental Support
12-month Bronze Node Software Supplemental Support
36-month Bronze Node Software Supplemental Support
60-month Bronze Node Software Supplemental Support
FM-D84U9-12 FM-D84V9-12
FM-D84U9-36 FM-D84V9-36
FM-D84U9-60 FM-D84V9-60
FM-D84US-12 FM-D84VS-12
FM-D84US-36 FM-D84VS-36
FM-D84US-60 FM-D84VS-60
FM-D84UN-12 FM-D84VN-12
FM-D84UN-36 FM-D84VN-36
FM-D84UN-60 FM-D84VN-60
Hardware and Software Supplemental Support Services Europe only
Europe does not offer specific part numbers for Hardware and Software Supplemental Support Services. Contact
Customer Services Sales in your country for information on Hardware and Software Supplemental Support
Services.
18
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 20 − Recommended Online Power Protection/UPS Solutions for GS140
For complete protection, UPS products should be used with data line surge protectors
4-wire RJ45 10BaseT, wall plug-in module, add up to four modules per plug in connection
17” din rail with 19” rackmount provisions for mounting up to 32 ports, rack or wall mount
Din rail mount surge protection module, 8-wire RJ45, 10/100BaseT twisted pair UL category 5
•
4N-GA249-CA
4N-GA245-AA
4N-GA245-EA
Powerware Plus 3-Phase UPS Models
•
All models are hardwired on input and rated 50/60 Hz; North American models are rated 176V-256V in,
100/200V, 120/208V, 127/220V out; international models are rated 380-415V in, 380/220V, 400/230V
415/240V out
UPS Models 15 and 18 kVA
North America 15 and 18kVA models are hardwired on output with optional plug-in receptacle panel
•
15kVA/10kW, 10 minutes battery time at full load, two batteries, North America or other 60-Hz
applications
18kVA/12kW, seven minutes battery time at full load, two batteries, North America or other 60-
Hz applications
15kVA/10kW, 16 minutes battery time at full load, two batteries, North America or other 60-Hz
applications
18kVA/12kW, 12 minutes battery time at full load, two batteries, North America or other 60-Hz
applications
15 kVA/10kW, 29 minutes of battery time at full load, three batteries, North America or other 60-
Hz applications
18kVA/12kW, 22 minutes of battery time at full load, three batteries, North America or other 60-
Hz applications
15 kVA/10kW, 10 minutes of battery time at full load, two batteries, international or other 50-Hz
applications, hardwired only
18kVA/12kW, seven minutes of battery time at full load, two batteries, international or other 50-
Hz applications, hardwired only
4N-AEAAN-BA
4N-AEAAP-BA
4N-AEAAN-BC
4N-AEAAP-BC
4N-AEAAN-BD
4N-AEAAP-BD
4N-AEAAN-BE
4N-AEAAP-BE
UPS Models 24 and 36kVA
•
Models are hardwired on output with optional 30 pole distribution cabinet, wraparound maintenance by-pass
and input filter; distribution cabinet accepts Square D circuit breakers
36kVA/24kW, five minutes of battery time at full load, one battery, North America or other 60-Hz
applications
24kVA/16kW, 30 minutes of battery time at full load, two batteries, North America or other 60-Hz
applications
36kVA/24kW, 15 minutes of battery time at full load, two batteries, North America or other 60-Hz
applications
24kVA/16kW, 50 minutes of battery time at full load, three batteries, North America or other 60-
Hz applications
4N-AEAAS-AA
4N-AEAAR-AB
4N-AEAAS-AB
4N-AEAAR-AC
4N-AEAAS-AC
36kVA/24kW, 30 minutes of battery time at full load, three batteries, North America or other 60-
Hz applications
15 and 18kVA UPS Receptacle Options, Extended Battery Options (Common configurations shown; other
receptacle options available)
•
Choose UPS receptacle option depending on input plug configuration of external storage cabinet used; ESA
10000 requires two L6-30R, SW800 requires two L21-30R, and GS140 Expansion Cabinet requires one L21-
30R
15/18kVA model output receptacle module, two L21-30R, three 5-20R2
4N-AEACM-BK
4N-AEACM-BN
4N-AEACM-PA
15/18kVA model output receptacle module, two L6-30R, two L21-30R, one 5-20R2
15/18kVA model output receptacle module; Module 1 − two L21-30R and conduit kit for
connecting Module 1 to Module 2; Module 2 − two L21-30R, three 5-20R2
Add-on battery cabinet for 15 and 18kVA models; can be added to Model 4N-AEAAN/P-BD −
4N-AEACH-BB
approximately 12 minutes per cabinet
19
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Options
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Step 20 − Recommended Online Power Protection/UPS Solutions for GS140 (continued)
24 and 36kVA UPS Auxiliary Cabinet Options
•
All cabinets contain wraparound external maintenance bypass switch
Auxiliary Cabinet with wraparound bypass only
4N-AEACP-AA
4N-AEACP-AB
4N-AEACP-BA
4N-AEACP-BB
Auxiliary Cabinet with 30 pole distribution
Auxiliary Cabinet with input harmonic distortion filter
Auxiliary Cabinet with 30 pole distribution and input harmonic distortion filter
Cabinets with 480V Input Transformer
Auxiliary Cabinet with 480V input transformer only
4N-AEACP-AC
4N-AEACP-AD
4N-AEACP-AE
4N-AEACP-BC
4N-AEACP-BD
Auxiliary Cabinet with 480V input transformer and 30 pole distribution
Auxiliary Cabinet with 480V input and 480V output transformer only
Auxiliary Cabinet with 480V input transformer and input harmonic distortion filter
Auxiliary Cabinet with 480V input transformer and 30 pole distribution and input harmonic
distortion filter
Auxiliary Cabinet with 480V input and 480V output transformer and input harmonic distortion
filter
4N-AEACP-BE
Note: Power cables with plug in circuit breakers and special receptacles also available for use with above
distribution cabinets.
UPS Monitoring and Unattended Shutdown Software
•
Power Management software communicates with recommended UPS; network adapter required for Tru64
UNIX; local port or terminal server required for OpenVMS; multi-interface module required for multiple servers
running OpenVMS
Connect-UPS network adapter, Twisted Pair, 60 Hz 120V NEMA
4N-AEAEO-DA
4N-AEAEO-DC
4N-AEAEO-DB
4N-AEAEO-DD
4N-JMIU4-AB
Connect-UPS network adapter ThinWire, 60 Hz 120V NEMA − Tru64 UNIX only
Connect-UPS network adapter, Twisted Pair, 50 Hz 240V IEC − Tru64 UNIX only
Connect-UPS network adapter, ThinWire, 50 Hz 240V IEC − Tru64 UNIX only
Multi-interface module, two to four OpenVMS systems on one UPS, includes splitter cable to
interface with network adapter (Tru64 UNIX) and terminal server output (OpenVMS) for
mixed operating platforms on one UPS; kits can be daisy-chained
Tru64 UNIX software kit
OpenVMS software kit
4N-AEAES-GA
4N-ONVMS-PL
20
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Power Configuration Table
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
AlphaServer GS140 EPU (Equivalent Power Units)–
Power Configuration Table
•
•
•
Combining 3-phase and 1-phase power regulators in system configuration is not allowed
Use chart to determine need for third power regulator
EPU must not exceed 180 (Note: EPUs listed in table based on LPAR tests)
EPU Values
System
EPU Values
Total EPU Expansion
(Qty times Cabinet
Total
EPU
Cabinet
(Qty times
EPU)
Options
Options
Quantity
1
EPU)
Options
Quantity
Expanded Base systems include 2 three phase
power regulators, CPU module, system I/O
module, PCI Plug-in-Unit, memory module
30
30
I/O expansion cabinet (H9F00-
BA/BB/BC/JC/JD/JE) includes one power
regulator
1
0
Additional dual 6/525 or 6/700 CPU modules—
762P1-AX, 762P2-AX, 3X-764P1-AX, 3X-764P2-AX
14
8
Additional dual 5/625 CPU modules—
758P1-AX, 758P2-AX
KFTHA-AA System I/O module
MS7CC-EA, 1-GB memory
MS7CC-FA, 2-GB memory
MS7CC-GA, 4-GB memory
Add PCI options
3
5
5
5
DWLPB-AA/AB/BA/BB
KZPSA-BB
1
1
1
1
1
1
1
KZPAC-AA/CA/CB
KZPBA-CA/CB
DE435-AA, DE450-AA, DE500-XA, DE500-xx
DEFPA-AB/DB/UB/MB
KFE70-AA/KFE72-xx
Add EISA options
CXI01-AA/AD
1
Disk and Tape options
8-bit SCSI disk drives
1
1
1
3
0
16-bit SCSI disk drives
TLZ07, TLZ09, TLZ9L, TLZ15-VA SCSI tape drive
TZ86, TZ87, TZ88 TZ89 -VA SCSI tape drive
DWZZB-VW SCSI signal converter
Total
Note: Depending on configuration, system offers integral UPS capability that supports all in-cabinet components for
at least 11 minutes. If UPS support is required for external devices, e.g., console terminals, terminal servers,
printers, and modems, universal UPS can be ordered separately.
21
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Upgrades
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Upgrades −Technical Information
•
•
Any slot not used in system card cage must be populated with terminator module (E2034-AA)
Required console terminal should be used for system control functions only; system users should be
connected through network/LAT connections
•
•
DWLPA-xx options not supported on GS140 systems
DWLAA FutureBus+ card cage and options not supported on GS140 systems; they must be removed from the
system
•
•
For Tru64 UNIX V4.0E GS140 applications, (DJ-ML200) PCI option must be at minimum module revision E;
(DJ-ML300-BA) daughter card on KFTIA is not supported and must be removed
See OpenVMS Alpha V7.1-2 Release Notes and Installation Procedures before installing OpenVMS V7.1-2
The following minimum I/O adapter firmware revisions are required with GS140 systems; see GS140 Installation
Notes (AV-RFCCA-TE) for more information.
CIPCA
CIXCD
DEFPA
DEMFA
A315
7
3.10
2.1
DEMNA
KZPBA
KDM70
KFMSB (B01)
9.4
5.57
4.4
1.0
KFMSB (>B01)
KZMSA
KZPSA
2.4
5.6
A11
System Speed Upgrades
AlphaServer 8400 5/300 or 5/350 to GS140 Upgrades
•
Upgrades include dual-CPU module (CPU clock module also included with AlphaServer 8400 5/300 and 5/350
upgrades) for Tru64 UNIX and OpenVMS systems only
•
•
Upgrade kits include all required hardware
Refer to "Systems Trade-in Menu" for 8400 5/440, 5/625, and GS140 6/525 to GS140 6/700 system speed
upgrade options
•
GS140 systems require Tru64 UNIX V4.0E or V4.0F or OpenVMS V7.2-1 or later
Uni 8400 5/300 or 5/350 to dual GS140 6/525 system upgrade, Tru64 UNIX license
Uni 8400 5/300 or 5/350 to dual GS140 6/525 system upgrade, OpenVMS license
Dual 8400 5/300 or 5/350 to dual GS140 6/525 system upgrade, no operating system license
Uni 8400 5/300 or 5/350 to dual GS140 6/700 system upgrade, Tru64 UNIX license
Uni 8400 5/300 or 5/350 to dual GS140 6/700 system upgrade, OpenVMS license
Dual 8400 5/300 or 5/350 to dual GS140 6/700 system upgrade, no operating system license
76U91-DX
76U91-EX
76U91-AX
3X-77U93-EX
3X-77U93-FX
3X-77U93-DX
SMP Speed Upgrades
•
•
All CPUs in GS140 must be at same speed
All upgrades require return of hardware; one-year hardware product warranty included
8400 5/300 or 5/350 dual-CPU module to GS140 6/525 dual-CPU module; includes processor module
with two Alpha 21264 525-MHz CPUs
8400 5/300 or 5/350 uni-CPU module to GS140 6/525 dual-CPU module; includes processor module
with two Alpha 21264 525-MHz CPUs and Tru64 UNIX SMP license
8400 5/300 or 5/350 uni-CPU module to GS140 6/525 dual-CPU module; includes processor module
with two Alpha 21264 525-MHz CPUs and OpenVMS SMP license
76U92-AX
76U92-BX
76U92-CX
In-Cabinet Upgrades
VAX/DEC 7000 to AlphaServer GS140 Upgrades
•
GS140 upgrade includes 9-slot backplane assembly, processor module with two Alpha microprocessor 21264
6/525 CPUs, each with 4-MB backup cache; KFTHA-AA system I/O module with 4 I/O channel connections;
operating system license; 90-day software product warranty, one-year product warranty
•
•
•
•
Memory not included with GS140 upgrades
Configuration must include GS140 dual-CPU module, KFTHA-AA I/O module, and memory module
Upgrades require return of replacement hardware
GS140 systems require Tru64 UNIX V4.0E or OpenVMS V7.1-2 or later
GS140 upgrade with 6/525 dual-CPU, KFTHA-AA I/O module, Tru64 UNIX
GS140 upgrade with 6/525 dual-CPU, KFTHA-AA I/O module, OpenVMS
DA-393HU-YX
DY-393HU-YX
22
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Upgrades
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
In-Cabinet Upgrades (continued)
In-cabinet CD-ROM
•
VAX 7000 requires RRDCD-CA option; CD-ROM requires single-ended SCSI-2 connection from KZMSA-AB in
XMI plug-in unit or KZPBA-CA in
PCI plug-in unit.
•
If EISA device support or the RAID Configuration Utility is required, select RRDCD-CA for space to mount
floppy disk drive; floppy drive included with KFE70 or KFE72 option.
•
•
CD-ROM device in StorageWorks shelf operates from PCI SCSI controller; DWZZA-VA is not supported.
All connections to CD-ROM device will stop at device; additional devices are not supported.
In-cabinet CD-ROM assembly, maximum of one per system; required if no CD-ROM device exists
in system being upgraded; includes CD-ROM device, mounting hardware, BN21H-0H cable
(0.75 m); order longer cable to reach XMI plug-in unit or PCI plug-in unit
RRDCD-CA
In-Cabinet 3-phase Power Expansion
•
If VAX/DEC 7000 being upgraded includes one H7263 power regulator, check equivalent power units to
determine if second power regulator is required; see Power Configuration Table.
3-phase 48 VDC power regulator with BBU capability; maximum of three per cabinet; second
regulator may be required to supply adequate power depending on configuration; third regulator
assures N+1 power redundancy and higher availability in the event of power regulator failure.
H7263-AA/AB
Same as H7263-AA/AB except no built-in battery backup (BBU) capability
H7263-AC/AD
VAX/DEC 7000 to AlphaServer GS140 In-Cabinet SMP Upgrades
•
Maximum of seven SMP modules (14 CPUs); if more than three modules are in system, a minimum of two
separate memory module should be ordered for optimal system performance
One VAX/DEC 7000 CPU module to GS140 6/525 dual-CPU module with OpenVMS SMP
extension license
One VAX/DEC 7000 CPU module to GS140 6/525 dual-CPU module with Tru64 UNIX SMP
extension license
Two VAX/DEC 7000 CPU modules to GS140 6/525 dual-CPU module with OpenVMS SMP
extension license
Two VAX/DEC 7000 CPU modules to GS140 6/525 dual-CPU module with Tru64 UNIX SMP
extension license
3X-76UAA-AX
3X-76UAB-AX
3X-76UBA-AX
3X-76UBB-AX
AlphaServer GS140 SMP Expansion Options
•
To add additional GS140 CPUs to upgraded system, order the following:
OpenVMS SMP expansion option; GS140 6/525 dual-CPU module, OpenVMS SMP extension
license
Tru64 UNIX SMP expansion option; GS140 6/525 dual-CPU module, Tru64 UNIX SMP extension
license
OpenVMS SMP expansion option; GS140 6/700 dual-CPU module, OpenVMS SMP extension
license
Tru64 UNIX SMP expansion option; GS140 6/700 dual-CPU module, Tru64 UNIX SMP extension
license
762P1-AX
762P2-AX
3X-764P1-AX
3X-764P2-AX
System Upgrades
AlphaServer 8200/GS60/GS60E to AlphaServer GS140 Upgrades
•
Complete box-swap system upgrades follow; system cabinet is replaced; however, existing 8200/GS60/GS60E
CPU, CPU clock module, memory, and I/O modules are transferable− see supported options listed in this
QuickSpec
•
Upgrades include GS140 system cabinet with 9-slot system bus, 3-phase power subsystem, PCI Plug-in-Unit
with 12-slot PCI shelf, StorageWorks Wide SCSI shelf for inclusion in PCI Plug-in-Unit, and upgrade
documentation
Dual 8200/GS60/GS60E to GS140 upgrade, Tru64 UNIX
DA-75U9A-AC/AD/AE
DY-75U9A-AC/AD/AE
Dual 8200/GS60/GS60E to GS140 upgrade, OpenVMS
Note: AC = 60 Hz, 208V, AD = 50 Hz, 380-416V, AE = 50/60 Hz, 202V (Japan)
23
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Technical Specifications
Compaq AlphaServer GS140
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
System Unit
Dimensions (HxWxD)
Shipping Dimensions
Weight Full Configuration
Without batteries
With batteries
Shipping Weight Full Configuration
Without batteries
With batteries
Clearances
67 x 31.5 x 34.4 in/170 x 80 x 87.5 cm
76.7 x 43.1 x 47.5 in / 195 x 109.5 x 121 cm
900 lbs/408 kg
1,200 lbs/545 kg
1000 lbs/448 kg
1300 lbs/585 kg
Operating
40 in/1 m
40 in/1 m
0
Service
59 in/1.5 cm
40 in/1 m
0
Front
Rear
Sides
Environmental
Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Altitude
Operating
Non-operating
Vibration
59° to 82°F/15° to 28°C
–40° to 151°F/–40° to 66°C
20% to 80%
10% to 95%
0 to 8,000 ft/0 to 2.4 km
30,000 ft/9,100 m
Operating
Non-operating
Heat Dissipation (1)
2 to 22 Hz @ 0.01″da minimum
22 to 500 Hz @ 0.25 g maximum
3,400 BTU/hr, 1,000W
15,700 BTU/hr, 4,600W
30,600 BTU/hr, 9,000W
Minimally configured system−system cabinet (1)
Fully configured system−system cabinet (2)
Fully configured system−system cabinet with 2 I/O
expansion cabinets (3)
Regulatory
UL Listed to UL1950
UL Classified to IEC950
CSA Certified to CAN/CSA-C22.2, No. 950-M89
FCC Part 15 (Class A)
CE Declaration #1171
Agency Approvals
AS 3260, Australian Standard
EN 60950, European Norm
Reviewed to
Power Requirements (1)
3-Phase Power Subsystem (2)
Nominal voltage
US/Canada
120/208V
Europe/AP
380-415V
Japan
202V
50 to 60 Hz
3-phase star
4-wire N-GND
50 to 60 Hz
3-phase star
4-wire N-GND
50 to 60 Hz
3-phase delta
4-wire mid-GND or
3-wire junction
GND
24 A rms
50 A peak
30 A
Frequency range
Phases
24 A rms
50 A peak
30 A
12.8 rms
50 A peak
16 A
Maximum input/current phase
Surge current
Rating
Power cap (system)
Receptacle (site)
(Industry equivalent)
PCS/PDS/PDU/UPS cable
DEC 12-12314-00 DEC 12-30333-02 DEC 12-12314-00
DEC 12-12315-01 See footnote 4
NEMA L21-30R IEC 309
DEC 12-12315-01
NEMA L21-30R
BC24W
BC24W
BN29X
24
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICKSPECS
Compaq AlphaServer GS140
Technical Specifications
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Minimally configured system contains one regulator, one CPU module, one memory module, one KFTIA-AA module, CD-ROM,
SCSI disk drive.
2
3
4
Fully configured system contains two power regulators, four CPU modules, three memory modules, two System I/O modules, 1
DWLPB-AA, one DWLPB-BA, three StorageWorks shelves, CD-ROM, 36 SCSI disk drives.
Fully configured system and expansion cabinets consist of the above “fully configured system” and two expansion cabinets that each
contain one DWLPB-AB, one DWLPB-BB, six KZPSA-BB, five StorageWorks shelves, 60 SCSI disk drives.
Receptacle type is Hubbell 516R6 or equivalent.
25
DA-10051-00A-008 — 02.28.2000
Download from Www.Somanuals.com. All Manuals Search And Download.
|