Compaq Network Card 64 Bit User Manual

Compaq StorageWorks 64-Bit/66-  
MHz Fibre Channel Host Adapter  
Installation Guide  
Second Edition (April 2001)  
Part Number 122833-002  
Compaq Computer Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Guide  
Text Conventions ......................................................................................................vii  
Symbols in Text .......................................................................................................viii  
Symbols on Equipment ............................................................................................viii  
Important Safety Information.....................................................................................ix  
Rack Stability.............................................................................................................. x  
Chapter 1  
Introduction  
Fibre Channel Host Adapter.....................................................................................1-1  
64-Bit/66-MHz Fibre Channel Host Adapter....................................................1-1  
Chapter 2  
Installing the 64-Bit/66-MHz Fibre Channel Host Adapter  
Updating System ROM ............................................................................................2-2  
Creating ROMPaq Utilities using the RA4100 SAN Solution Support Software  
CD ............................................................................................................................2-2  
Creating ROMPaq Utilities using the Compaq SmartStart and Support  
Software CD.............................................................................................................2-2  
Materials Needed ..............................................................................................2-3  
Creating Diskettes .............................................................................................2-3  
Running System ROMPaq ................................................................................2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter Installation Guide  
Installing the 64-Bit/66-MHz Fibre Channel Host Adapter  
continued  
Hardware Installation .............................................................................................. 2-5  
Multi-Mode Fibre Channel Cables................................................................... 2-5  
Shortwave GBIC Modules ............................................................................... 2-7  
Optional Longwave GBIC Modules................................................................. 2-8  
Installing the GBIC and Fibre Channel Cable.................................................. 2-8  
Chapter 3  
Installing Drivers for Novell NetWare  
Installing the Drivers ............................................................................................... 3-2  
Driver Installation from the RA4100 SAN Solution Support Software CD..... 3-2  
Driver Installation from the Compaq SmartStart and Support Software CD.... 3-2  
Additional Information..................................................................................... 3-3  
Chapter 4  
Installing Drivers for Microsoft Windows NT  
Installing the Drivers ............................................................................................... 4-1  
Driver Installation from the RA4100 SAN Solution Support Software CD..... 4-2  
Driver Installation from the Compaq SmartStart and Support Software CD.... 4-2  
Chapter 5  
Installing Drivers for Microsoft Windows 2000  
Installing the Drivers ............................................................................................... 5-1  
Driver Installation from the RA4100 SAN Solution Support Software CD..... 5-2  
Driver Installation from the Compaq SmartStart and Support Software CD.... 5-2  
Updating the 64-Bit/66-MHz Fibre Channel Host Adapter Driver using  
Compaq SmartStart and Support Software CD ................................................ 5-4  
Chapter 6  
Installing Drivers for SCO OpenServer 5.0  
Installing the Drivers ............................................................................................... 6-2  
Materials Needed to Install Drivers using Compaq SmartStart and Support  
Software CD..................................................................................................... 6-2  
Creating the EFS Diskettes............................................................................... 6-2  
Accessing Installation Information................................................................... 6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents v  
Chapter 7  
Installing Drivers for Linux  
Installing the Drivers................................................................................................7-2  
Materials Needed to Install Drivers using Compaq SmartStart and Support  
Software CD......................................................................................................7-2  
Creating the EFS Diskettes ...............................................................................7-2  
Installing Linux Fibre Channel Driver for Red Hat 6.2 ....................................7-3  
Installing Linux Fibre Channel Driver for Red Hat 7.0 ....................................7-4  
Chapter 8  
Installing Drivers for SCO UnixWare  
Installing the Driver .................................................................................................8-1  
Materials Needed to Install Drivers using Compaq SmartStart and Support  
Software CD......................................................................................................8-2  
Accessing the Driver Installation Information ..................................................8-3  
Appendix A  
Regulatory Compliance Notices  
Federal Communications Commission Notice........................................................A-1  
Class A Equipment...........................................................................................A-2  
Class B Equipment...........................................................................................A-2  
Modifications ...................................................................................................A-3  
Cables...............................................................................................................A-3  
Canadian Notice (Avis Canadien)...........................................................................A-3  
Class A Equipment...........................................................................................A-3  
Class B Equipment...........................................................................................A-4  
European Union Notice...........................................................................................A-4  
Japanese Notice.......................................................................................................A-5  
Taiwanese Notice ....................................................................................................A-5  
Appendix B  
Electrostatic Discharge  
Grounding Methods................................................................................................. B-2  
Index  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Guide  
This guide is designed to be used as step-by-step instructions for installation  
and as a reference for operation, troubleshooting, and future upgrades.  
Text Conventions  
This document uses the following conventions to distinguish elements of text:  
Keys  
Keys appear in boldface. A plus sign (+) between  
two keys indicates that they should be pressed  
simultaneously.  
USER INPUT  
User input appears in a different typeface and in  
uppercase.  
FILENAMES  
File names appear in uppercase italics.  
Menu Options,  
These elements appear in initial capital letters.  
Command Names,  
Dialog Box Names  
COMMANDS,  
These elements appear in uppercase.  
DIRECTORY NAMES,  
and DRIVE NAMES  
Type  
When you are instructed to type information, type  
the information without pressing the Enter key.  
Enter  
When you are instructed to enter information, type  
the information and then press the Enter key.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
viii Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter Installation Guide  
Symbols in Text  
The following symbols are found in the text of this guide to indicate different  
types of information.  
WARNING: Text set off in this manner indicates that failure to follow directions  
in the warning could result in bodily harm or loss of life.  
CAUTION: Text set off in this manner indicates that failure to follow directions  
could result in damage to equipment or loss of information.  
IMPORTANT: Text set off in this manner presents clarifying information or specific  
instructions.  
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of  
information.  
Symbols on Equipment  
The following symbols are placed on equipment to indicate the presence of  
potentially hazardous conditions:  
This symbol in conjunction with any of the following symbols indicates the  
presence of a potential hazard. The potential for injury exists if warnings  
are not observed. Consult your documentation for specific details.  
This symbol indicates the presence of hazardous energy circuits or electric  
shock hazards. Refer all servicing to qualified personnel.  
WARNING: To reduce the risk of injury from electric shock hazards, do not  
open this enclosure. Refer all maintenance, upgrades, and servicing to  
qualified personnel.  
This symbol indicates the presence of electric shock hazards. The area  
contains no user or field serviceable parts. Do not open for any reason.  
WARNING: To reduce the risk of injury from electric shock hazards, do  
not open this enclosure.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Contents ix  
This symbol on an RJ-45 receptacle indicates a Network Interface  
Connection.  
WARNING: To reduce the risk of electric shock, fire, or damage to the  
equipment, do not plug telephone or telecommunications connectors into  
this receptacle.  
This symbol indicates the presence of a hot surface or hot component. If  
this surface is contacted, the potential for injury exists.  
WARNING: To reduce the risk of injury from a hot component, allow the  
surface to cool before touching.  
These symbols on power supplies or systems indicate the  
equipment is supplied by multiple sources of power.  
WARNING: To reduce the risk of injury from electric shock,  
remove all power cords to completely disconnect power from  
the system.  
This symbol indicates that the component exceeds the recommended  
weight for one individual to handle safely.  
Weight in kg  
Weight in lb  
WARNING: To reduce the risk of personal injury or damage to the  
equipment, observe local occupational health and safety requirements and  
guidelines for manual material handling.  
Important Safety Information  
Before installing this product, read the Important Safety Information document  
provided.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
x
Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter Installation Guide  
Rack Stability  
WARNING: To reduce the risk of personal injury or damage to the equipment, be  
sure that:  
I
I
I
I
I
The leveling jacks are extended to the floor.  
The full weight of the rack rests on the leveling jacks.  
The stabilizing feet are attached to the rack if it is a single rack installation.  
The racks are coupled in multiple rack installations.  
Only one component is extended at a time. A rack may become unstable if  
more than one component is extended for any reason.  
Getting Help  
If you have a problem and have exhausted the information in this guide, you  
can get further information and other help in the following locations.  
Compaq Technical Support  
In North America, call the Compaq Technical Phone Support Center at  
1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week.  
For continuous quality improvement, calls may be recorded or monitored.  
Outside North America, call the nearest Compaq Technical Support Phone  
Center. Telephone numbers for worldwide Technical Support Centers are  
listed on the Compaq website. Access the Compaq website at  
Be sure to have the following information available before you call Compaq:  
I
I
I
I
I
I
I
Technical support registration number (if applicable)  
Product serial number  
Product model name and number  
Applicable error messages  
Add-on boards or hardware  
Third-party hardware or software  
Operating system type and revision level  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Contents xi  
Compaq Website  
The Compaq website has information on this product as well as the latest  
drivers and Flash ROM images. You can access the Compaq website at  
Compaq Authorized Reseller  
For the name of your nearest Compaq authorized reseller:  
I
I
I
In the United States, call 1-800-345-1518.  
In Canada, call 1-800-263-5868.  
Elsewhere, see the Compaq website for locations and telephone  
numbers.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter  
1
Introduction  
Fibre Channel Host Adapter  
The Compaq StorageWorks Fibre Channel Host AdapterTM is available in  
64-Bit/66-MHz PCI. The option kit (part number 120186-B21) contains this  
StorageWorks Fibre Channel Host Adapter.  
64-Bit/66-MHz Fibre Channel Host Adapter  
The 64-Bit/66-MHz Fibre Channel Host Adapter is installed in a server with a  
PCI local bus and provides an interface between the PCI bus in the server and  
Fibre Channel-connected external storage systems.  
The 64-Bit/66-MHz Fibre Channel Host Adapter interface to the server is the  
Peripheral Component Interconnect (PCI) bus. The PCI interface is a  
high-performance, 64-Bit/66-MHz bus with multiplexed address and data  
lines, and parity information. It provides a high-speed (up to 528 MB/s) path  
between the system board and the Host Adapter. The 64-Bit/66-MHz Fibre  
Channel Host Adapter is a PCI Bus Master device and conforms to the current  
PCI Local Bus Specification.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1-2 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter  
The Host Adapter requires the installation of a GigaBit Interface Converter  
(GBIC) module before the Fibre Channel cable is connected. The GBIC  
converts electrical signals to optical signals, and vice versa, for transmission  
across the Fibre Channel media. The Fibre Channel cable connector is plugged  
into the installed GBIC module.  
Figure 1-1. 64-Bit/66-MHz Fibre Channel Host Adapter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter  
2
Installing the 64-Bit/66-MHz Fibre  
Channel Host Adapter  
The installation of the Compaq StorageWorks 64-Bit/66-MHz Fibre Channel  
Host Adapter and its connection to Fibre Channel storage systems must be  
completed in a step-by-step process. See Table 2-1 for installation steps.  
Table 2-1  
64-Bit/66-MHz Fibre Channel Host Adapter Installation Steps  
Step  
Task  
Go to Chapter/Guide  
1
Run System ROMPaq.  
See “Running System ROMPaq”  
section in Chapter 2.  
2
Install the 64-Bit/66-MHz Fibre  
Refer to your server  
Channel Host Adapter in the server.  
documentation for specific  
installation instructions.  
3
4
Install the GigaBit Interface  
Converter (GBIC) module.  
See the “Hardware Installation”  
section in Chapter 2.  
Connect the Multi-Mode Fibre  
Channel cable to the 64-Bit/66-MHz  
Fibre Channel Host Adapter.  
See the “Hardware Installation”  
section in Chapter 2.  
5
Run the RA4100 SAN Solution  
Support Software CD or the Compaq  
SmartStart and Support Software  
CD to load the drivers.  
See Chapters 3 through 8.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-2 Compaq StorageWorks 64-Bit/66- MHz Fibre Channel Host Adapter  
Updating System ROM  
The ROM on all Compaq servers can be updated easily by flashing the ROM  
using a special Compaq utility called System ROMPaq. This utility replaces  
the existing contents of the ROM with another version stored in a disk file.  
This is a convenient method to distribute new firmware to update Compaq  
products with the latest capabilities.  
IMPORTANT: Before installing the new 64-Bit/66-MHz Fibre Channel Host Adapter in the  
server, run System ROMPaq to update the system ROM. Follow the instructions found in  
the section “Creating ROMPaq Utilities using the RA4100 SAN Solution Support Software  
CD” to create ROMPaq utilities using the RA4100 SAN Solution Support Software CD.  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software. Follow the instructions found in the section, “Creating ROMPaq  
Utilities using the Compaq SmartStart and Support Software CD” to create diskettes that  
will run the ROMPaq utilities using the Compaq SmartStart and Support Software CD.  
NOTE: The System ROMPaq is used to update the system ROM in all Compaq servers that  
support Flash ROM.  
Creating ROMPaq Utilities using the  
RA4100 SAN Solution Support Software  
CD  
To run the Options ROMPaq from the RA4100 Support Software CD:  
1. Boot up the system using the RA4100 Support Software CD.  
2. At the menu screen, select the option, Run Options ROMPaq Utility.  
This will launch the utility that will detect and update the firmware.  
Creating ROMPaq Utilities using the  
Compaq SmartStart and Support  
Software CD  
The latest version of the ROMPaq diskettes can be created from the Compaq  
SmartStart and Support Software CD. The ROMPaq utilities must be run from  
diskettes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the 64-Bit/66-MHz Fibre Channel Host Adapter 2-3  
Materials Needed  
The following items are necessary to create ROMPaq utility diskettes:  
I
I
I
Compaq SmartStart and Support Software CD  
One blank diskette  
A server or workstation with a bootable CD-ROM drive. The system in  
which you are installing the 64-Bit/66-MHz Fibre Channel Host Adapter  
can be used.  
Creating Diskettes  
To create ROMPaq diskettes:  
1. Start the server from the Compaq SmartStart and Support Software CD.  
2. From the Compaq System Utilities screen, select Create Support  
Software.  
3. From the Diskette Builder screen, scroll down the list and select one of  
the following five ROMPaq selections:  
! System ROMPaq Firmware Upgrade Diskette for Compaq  
Systempro/XL, ProSignia 386E5, E8, VS, 300/500, 200(P01), and  
200(P05) Servers  
! System ROMPaq Firmware Upgrade Diskette for Compaq  
ProLiant 1000, 1500(E12), 1500(E27), 2000/4000, 4500, and  
5000 Servers  
! System ROMPaq Firmware Upgrade Diskette for Compaq  
ProLiant 800(P02), 850R, 1200, 1600(E34), 2500, 3000, and  
5500 Servers  
! System ROMPaq Firmware Upgrade Diskette for Compaq  
ProLiant 6000, 6500, and 7000 Servers  
! System ROMPaq Firmware Upgrade Diskette for Compaq  
ProLiant 800(P18) and 1600(P08) Servers  
4. Follow the instructions on the screen to create the ROMPaq diskettes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-4 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter  
Running System ROMPaq  
System ROMPaq is used to update the firmware in Compaq servers. The new  
storage systems have enhanced drive array capabilities and many existing  
servers require updated firmware to take advantage of these capabilities. Since  
it is difficult to determine when the firmware was last updated, Compaq  
recommends running the latest System ROMPaq on your server before  
installing a new 64-Bit/66-MHz Fibre Channel Host Adapter.  
To run System ROMPaq:  
1. Place the System ROMPaq diskette in the server diskette drive.  
2. Start the server by turning on the power.  
3. Press Enter at the Welcome screen.  
4. At the Select A Device screen, select the server from the list of  
programmable devices. There may only be one item in the list.  
Press Enter.  
5. At the Select An Image screen, you will see:  
Device to reprogram:  
Current ROM revision:  
Select Firmware Images:  
your server  
date of existing ROM version  
date of latest ROM version  
Press Enter.  
6. Review the information on the Caution screen:  
Device to reprogram:  
Current ROM revision:  
Selected ROM revision:  
your server  
date of existing ROM version  
date of ROM version to be installed  
Press Enter to reprogram the system ROM or Esc (escape) to  
discontinue reprogramming and return to the Select An Image screen.  
Do not interrupt when “Reprogramming Firmware” appears on the  
screen. The system ROM is being reprogrammed.  
IMPORTANT: Do not interrupt the reprogramming. Interrupting the ROM reprogramming  
will leave the firmware in an unknown state. You may not be able to boot the server if this  
happens. You will be notified when reprogramming is completed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the 64-Bit/66-MHz Fibre Channel Host Adapter 2-5  
7. When ROMPaq has finished reprogramming the system ROM, press  
Esc to exit the System ROMPaq Utility.  
8. Remove the System ROMPaq diskette and restart the server by cycling  
the power (cold start).  
This completes the firmware update using System ROMPaq.  
Hardware Installation  
Install the 64-Bit/66-MHz Fibre Channel Host Adapter in an available slot in  
the server. Refer to the server documentation for installation instructions for  
option boards.  
WARNING: To reduce the risk of personal injury or damage to the equipment,  
consult the safety information and user documentation provided with your  
computer before attempting this installation.  
Many personal computers are capable of producing energy levels that are  
considered hazardous. These computers are intended to be serviced by qualified  
personnel trained to deal with these hazards. Do not remove enclosures or  
attempt to bypass any interlocks that may be provided for the purpose of  
removing these hazardous conditions.  
NOTE: You can select any available 32-bit or 64-bit PCI slot to install the Host Adapter. For  
best performance, a 64-bit slot should be used.  
Multi-Mode Fibre Channel Cables  
Multi-Mode Fibre Channel cables are used to connect distances up to 500  
meters. A shortwave GBIC module must be used with these cables. A 5-m  
Multi-Mode Fibre Channel Cable is included in your 64-Bit/66-MHz Fibre  
Channel Host Adapter kit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-6 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter  
IMPORTANT: To ensure product integrity, Compaq recommends a 50/125 µm  
multi-mode optical fiber that complies with Bellcore GR409. The cable assembly should  
be terminated with SC Duplex Connectors (super polished ferrule) at each end. These  
connectors must be NNT-SC-, Bellcore 326-, and IEC-874-19 SC-compliant.  
NOTE: To connect distances between 500 meters and 10 kilometers, a single-mode Fibre  
Channel cable and matching pair of longwave GigaBit Interface Converters (GBIC-LWs)  
must be purchased. A list of fibre channel cable suppliers can be found at  
Figure 2-1. Fibre Channel cable with connectors  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the 64-Bit/66-MHz Fibre Channel Host Adapter 2-7  
Shortwave GBIC Modules  
Your StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter option kit  
contains two shortwave GBIC modules. A multi-mode Fibre Channel cable  
must be used with shortwave GBICs.  
Figure 2-2. GigaBit Interface Converter (GBIC) module  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2-8 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter  
Optional Longwave GBIC Modules  
To connect distances between 500 meters and 10 kilometers, you must use  
longwave GBIC modules and a single-mode fibre channel cable. A Longwave  
GigaBit Interface Converter (GBIC-LW) Connector Kit  
(part number 340412-B21) is available.  
IMPORTANT: To ensure product integrity, Compaq recommends a 9/125 µm single-mode  
optical fiber that complies with Bellcore GR409. The cable assembly should be terminated  
with SC Duplex Connectors (super polished ferrule) at each end. These connectors must  
be NNT-SC-, Bellcore 326-, and IEC-874-19 SC-compliant.  
NOTE: Single-mode Fibre Channel cables are not provided with this kit. A list of fibre  
Installing the GBIC and Fibre Channel Cable  
To install the GBIC module and Fibre Channel cable:  
1. Insert the GBIC module into the receptacle on the 64-Bit/66-MHz Fibre  
Channel Host Adapter. The GBIC module can only be installed one  
way. The GBIC and the guide rails inside the Host Adapter receptacle  
are keyed.  
2. Insert one end of the Fibre Channel cable connector into the installed  
GBIC module. The GBIC module and the Fibre Channel cable  
connector are keyed to prevent an improper installation. Support the  
installed Fibre Channel cable to prevent a bend radius of less than  
3 inches (76.2 millimeters.) Support and route the Fibre Channel cable  
to prevent damage from sharp edges or from being crushed by nearby  
equipment.  
This completes the installation of the GBIC module and Fibre Channel cable  
in the 64-Bit/66-MHz Fibre Channel Host Adapter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter  
3
Installing Drivers for Novell NetWare  
This chapter outlines the driver installation steps for Novell NetWare 4.2 and  
5.1 operating systems. If you are setting up a new system with Novell  
NetWare, use the RA4100 SAN Solution Support Software CD when  
installing the Novell NetWare operating system and the device drivers.  
NOTE: To install the drivers from the RA4100 SAN Solution Support Software CD, follow  
the instructions found inside the CD-ROM sleeve.  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software. If the SmartStart and Support Software CD is used to install your  
operating system software, all required software, including device drivers, will be  
automatically installed and configured.  
Before installing the drivers, you must:  
I
Update your system firmware by running System ROMPaq (see  
Chapter 2).  
I
Configure the hardware by running the System Configuration Utility.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-2 MHz Fibre Channel Host Adapter Installation Guide  
Installing the Drivers  
Follow the instructions in this chapter to install the drivers manually for a new  
installation or to upgrade the drivers in an existing NetWare server.  
Driver Installation from the RA4100 SAN Solution  
Support Software CD  
The latest Novell NetWare drivers and support files for the 64-Bit/66-MHz  
Fibre Channel Host Adapter are located on the RA4100 SAN Solution Support  
Software CD. To install the drivers from the RA4100 SAN Solution Support  
Software CD, follow the instructions found inside the RA4100 SAN Solution  
Support Software CD-ROM sleeve.  
IMPORTANT: Before installing or upgrading support for your Compaq 64-Bit/66-MHz  
Fibre Channel Host Adapter, make sure you have installed the latest Novell Support Pack  
for the version of the NetWare operating system in use. Novell Support Packs can be  
obtained at support.novell.com  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software.  
Driver Installation from the Compaq SmartStart  
and Support Software CD  
1. From the NetWare 4.2 console, type:  
Load Install  
or  
From the NetWare 5.1 console, type:  
Load Nwconfig  
2. Select Product Options from the menu and press Enter.  
3. Select Install a product not listed and press Enter.  
4. Press F3 to specify a different path.  
5. Insert the Compaq SmartStart and Support Software CD into the  
server’s CD-ROM drive.  
6. Do one of the following:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing Drivers for Novell NetWare 3-3  
a. Mount the CD-ROM as a NetWare volume, enter the path, and then  
press Enter. (xxx in the volume name is the SmartStart version  
number.)  
CPQSMSTxxx:\CPQSUPSW\NSSD  
or  
b. If the DOS CD-ROM driver support is loaded, enter the path and  
press Enter.  
<CD-ROM drive letter>:\CPQSUPSW\NSSD  
7. Press Enter to bypass the Welcome screen.  
8. Select Compaq NWPA Storage Support from the menu by scrolling  
down to it, then press F5 to mark the selection.  
IMPORTANT: Install the SmartStart and Support Software CD as a package.  
9. Press Tab for the Main Menu.  
10. Select Install Selected Files by pressing Enter.  
11. After viewing the Install Results, press Enter.  
12. Select To Reboot Server and follow the on-screen instructions to load  
the new or upgraded device drivers on your server. Your  
STARTUP.NCF file will be updated automatically with the appropriate  
driver load statements.  
Additional Information  
Readme files containing the latest information about using Compaq options in  
a NetWare environment (including driver installation procedures) are included  
on the SmartStart and Support Software. These files are located in the  
\CPQSUPSW\NSSD directory. To read these help files:  
I
Execute README.COM to view and print the STORAGE.RDM help  
file.  
I
Alternatively, NSSD.HLP, a Microsoft Windows Help File, can be  
viewed by double-clicking the NSSD.HLP icon.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter  
4
Installing Drivers for Microsoft  
Windows NT  
This chapter outlines the driver installation steps for a Windows NT 4.0 or  
later operating system. If you are setting up a new system with Windows NT,  
use the RA4100 SAN Solution Support Software CD to install the drivers  
necessary to support the 64-Bit/66-MHz Fibre Channel Host Adapter.  
NOTE: To install the drivers from the RA4100 SAN Solution Support Software CD, follow  
the instructions found inside the CD-ROM sleeve.  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software. If the SmartStart and Support Software CD is used to install your  
operating system software, all required software, including device drivers, will be  
automatically installed and configured.  
Before installing the drivers, you must:  
I
Update your system firmware by running System ROMPaq (see  
Chapter 2).  
I
Configure the hardware by running the System Configuration Utility.  
Installing the Driver  
Installing the Drivers  
Follow the instructions in this section to install the initial driver manually for a  
new 64-Bit/66-MHz Fibre Channel Host Adapter installation or to upgrade the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4-2 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter  
driver in an existing Windows NT 4.0 server with a 64-Bit/66-MHz Fibre  
Channel Host Adapter.  
Driver Installation from the RA4100 SAN Solution  
Support Software CD  
The latest drivers and support files for Windows NT are located on the  
RA4100 SAN Solution Support Software CD. To install the drivers from the  
RA4100 SAN Solution Support Software CD, follow the instructions found  
inside the CD-ROM sleeve.  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software.  
Driver Installation from the Compaq SmartStart  
and Support Software CD  
Use the following steps to install or update the Microsoft Windows NT  
drivers:  
Use the following steps to install or update the Windows NT drivers:  
1. Insert the SmartStart and Support Software CD. If you have enabled  
AutoPlay, the System Utilities window appears.  
2. Select I Agree box and click the OK button.  
3. The pop-up System Utilities window appears with 2 options, as shown  
in the figure below.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing Drivers for Microsoft Windows NT 4-3  
Figure 4-1. System Utilities window  
4. Select option 2, Install Compaq Support Paq, and click the OK button.  
5. The Compaq Remote Deployment Utility dialog box appears, as shown  
in Figure 4-2.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-4 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter  
Figure 4-2. Compaq Remote Deployment Utility  
6. Click the Item menu and select Deselect All.  
7. Click the checkbox next to Compaq StorageWorks Fibre Channel Host  
Bus Adapter Drivers.  
8. Click the Install button at the top of the window.  
9. When the file copy is complete, you will receive a message that the  
installation was successful.  
10. Close the Compaq Remote Deployment Utility dialog box.  
11. Close the System Utility menu (Click OK if the system prompts you to  
restart.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter  
5
Installing Drivers for Microsoft  
Windows 2000  
This chapter outlines the driver installation steps for a Windows 2000. If you  
are setting up a new system with Windows 2000, use the RA4100 SAN  
Solution Support Software CD to install the drivers necessary to support the  
64-Bit/66-MHz Fibre Channel Host Adapter.  
NOTE: To install the drivers from the RA4100 SAN Solution Support Software CD, follow  
the instructions found inside the CD-ROM sleeve.  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software. If the SmartStart and Support Software CD is used to install your  
operating system software, all required software, including device drivers, will be  
automatically installed and configured.  
Before installing the drivers, you must:  
I
Update your system firmware by running System ROMPaq (see  
Chapter 2).  
I
Configure the hardware by running the System Configuration Utility.  
Installing the Drivers  
Follow the instructions in this section to install the initial driver manually for a  
new 64-Bit/66-MHz Fibre Channel Host Adapter installation or to upgrade the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5-2 Compaq StorageWorks 64-Bit/66-MHz Fibre Channel Host Adapter Installation Guide  
driver in an existing Windows 2000 server with a 64-Bit/66-MHz Fibre  
Channel Host Adapter.  
Driver Installation from the RA4100 SAN Solution  
Support Software CD  
The latest drivers and support files for Windows 2000 are located on the  
RA4100 SAN Solution Support Software CD. To install the drivers from the  
RA4100 SAN Solution Support Software CD, follow the instructions found  
inside the CD-ROM sleeve.  
NOTE: Compaq SmartStart and Support Software CD with a higher revision number than  
the RA4100 SAN Solution Support Software may contain an updated version of RA4100  
SAN Solution software.  
Driver Installation from the Compaq SmartStart  
and Support Software CD  
Use the following steps to install the Microsoft Windows 2000 drivers:  
1. Insert the Compaq SmartStart and Support Software CD. If you have  
enabled AutoPlay, the System Utilities window appears.  
2. Select I Agree box and click the OK button.  
3. The pop-up System Utilities window appears with 2 options, as shown  
in the figure below.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing Drivers for Microsoft Windows 2000 5-3  
Figure 5-1. System Utilities window  
4. Select option 2, Install Compaq Support Paq, and click the OK button.  
5. The Compaq Remote Deployment Utility dialog box appears, as shown  
in the figure below.  
Download from Www.Somanuals.com. All Manuals Search And Download.