Coleman Stove 3001 Series User Manual

TM  
Butane/Propane Stove  
Instructions for use  
© 2005 The Coleman Company, Inc.  
3001 Series  
ANSI Z21.72b - CSA 11.2b (2002)  
Camp Stove  
®
IMPORTANT  
Read this manual carefully before assembling, using or servicing these stoves. Keep  
this manual for future reference. If you have questions about assembly, operation,  
servicing or repair of these stoves, please call Coleman at 1-800-835-3278 or TDD:  
316-832-8707. In Canada call 1-800-387-6161.  
The Coleman Company, Inc. • 3600 N. Hydraulic • Wichita, KS 67219 U.S.A.  
1-800-835-3278 • TDD: 316-832-8707  
© 2005 The Coleman Company, Inc. All rights reserved. Coleman®,  
and PEAK 1® are registered trademarks and  
is a trademark of The Coleman Company, Inc.  
3001-050 (11/14/05)  
ME  
f.d07.1829  
Download from Www.Somanuals.com. All Manuals Search And Do  
E
w
n
A
loRe  
a
WARNING  
WARNING  
• This product is fueled by LPG. LPG is invisible,  
odorless, and flammable. An odorant is  
normally added to help detect leaks and can  
be described as a ”rotten egg” smell. The  
odorant can fade over time so leaking gas is  
not always detectable by smell alone.  
• BURN HAZARD  
• Never leave stove unattended when hot  
or in use.  
• Keep out of reach of children.  
• LPG is heavier than air and leaking LPG will  
sink to the lowest level possible. It can ignite by  
ignition sources including matches, lighters,  
sparks or open flames of any kind many feet  
away from the original leak. Use only LPG set  
up for vapor withdrawal.  
DANGER  
• LPG should be stored or used in compliance with  
local ordinances and codes or with ANSI/NFPA  
58. Turn off LPG when not in use.  
• CARBON MONOXIDE HAZARD  
• This stove is a combustion appliance. All  
combustion appliances produce carbon  
monoxide (CO) during the combustion  
process. This product is designed to produce  
extremely minute, non-hazardous amounts of  
CO if used and maintained in accordance with  
all warnings and instructions. Do not block air  
flow into or out of the stove.  
• Carbon Monoxide (CO) poisoning produces  
flu-like symptoms, watery eyes, headaches,  
dizziness, fatigue and possibly death. You  
can’t see it and you can’t smell it. It’s an  
invisible killer. If these symptoms are present  
during operation of this product get fresh  
air immediately!  
DANGER  
• EXPLOSION - FIRE HAZARD  
• Never store LPG (liquefied petroleum gas) near  
high heat, open flames, pilot lights, direct  
sunlight, other ignition sources or where  
temperatures exceed 120 degrees F (49°C).  
• LPG is heavier than air and can accumulate in  
low places. If you smell gas, leave the  
area immediately.  
• Never install or remove LPG cylinder while  
outdoor stove is lighted, near flame, pilot lights,  
other ignition sources or while outdoor stove is  
hot to touch.  
• During lighting and operation, this product can  
be a source of ignition. Never use the stove in  
spaces that contain or may contain volatile or  
airborne combustibles, or products such as  
gasoline, solvents, paint thinner, dust particles  
or unknown chemicals. Minimum clearances  
from combustible materials: 24 inches from the  
sides and 48 inches from the top.  
For outdoor use only.  
Never use inside house, camper, tent,  
vehicle or other unventilated or enclosed  
areas. This stove consumes air (oxygen).  
Do not use in unventilated or enclosed  
areas to avoid endangering your life.  
CAUTION  
• SERVICE SAFETY  
• Provide adequate clearances around air  
openings into the combustion chamber.  
• Use only LPG set up for vapor withdrawal.  
• Keep all connections and fittings clean.  
Always inspect gas cartridge, stove  
connections and “O” ring seal for damage, dirt  
and debris before attaching cartridge (Fig. 1).  
Replace if damaged or worn. Never use stove  
with damaged or worn seals.  
WARNING  
Not for home or recreational vehicle use.  
• During set up, CHECK FOR LEAKS in one or  
more ways: Apply soapy water to connections.  
Bubbles indicate a leak. Listen for hiss of  
escaping gas. Feel for extreme cold. Smell for  
rotten egg odor. Never use a flame. Check  
that the connection is not cross-threaded and  
that it is tight. Perform another leak check. If  
there is still a leak, remove the cylinder and  
contact Coleman for service or repairs.  
• Use as a cooking appliance only. Never alter  
in any way or use with any device or part not  
expressly approved by Coleman.  
We cannot foresee every use which may be  
made of our products.  
Check with your local fire safety authority if  
you have questions about use.  
Other standards govern the use of fuel gases  
and heat producing products for specific uses.  
Your local authorities can advise you  
about these.  
• Never refill disposable cylinders.  
• Use only Coleman® accessories or parts.  
During stove set-up, check all fittings for  
leaks using soapy water. Never use a flame.  
• Never use as a space heater.  
• Clean stove frequently to avoid grease  
accumulation and possible grease fires.  
English-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Screw LPG cylinder into stove. Take care not to  
cross thread. HAND TIGHTEN only. (Fig. 3)  
“O” Ring  
Fig. 1  
Technical  
Characteristics  
Input: 10,000 BTU/H  
Category: Unregulated LPG  
Fuel: 7 3/4 oz. disposable  
butane/propane mix cylinders  
To Set Up  
Fig. 3  
DANGER  
Set pan supports to desired position. (Fig. 4, 5,  
and 6)  
• CARBON MONOXIDE HAZARD  
• For outdoor use only.  
• Never use inside house, camper, tent, vehicle  
or other unventilated or enclosed areas. This  
stove consumes air (oxygen). Do not use in  
unventilated or enclosed areas to avoid  
endangering your life.  
NOTE: Use Coleman® 7 3/4 oz. disposable  
butane/propane mix cylinder only. Do not connect  
to bulk LPG systems. The LP-gas cylinder(s)  
used with stoves must be constructed and  
marked in accordance with the specifications for  
LP-gas cylinders of the U.S. Department of  
Transportation or Transport Canada, CAN/CSA  
B339.  
CAUTION  
• SERVICE SAFETY  
• Keep all connections and fittings clean.  
Inspect LPG cylinder and stove LPG connec-  
tions for damage before attaching.  
• During set up, check all connections and  
fittings for leaks using soapy water. Bubbles  
indicate a leak. Never use a flame.  
Fig. 4  
Take stove outdoors away from ignition sources.  
Turn fuel valve off. (Fig. 2)  
Fig. 2  
Fig. 5  
English-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Match Light:  
Set on sturdy, flat surface. For outdoor use only.  
Hold lighted match at burner and open FUEL  
VALVE. (Fig. 7)  
Fig. 6  
Leak Check  
Fig. 7  
WARNING  
Adjust flame to desired heat with FUEL VALVE.  
(Fig. 8)  
Flame should be blue with hint of yellow on tips.  
• Perform leak test outdoors.  
• Extinguish all open flames.  
• NEVER leak test when smoking.  
• Do not use the outdoor stove until connection  
has been leak tested and does not leak.  
CHECK FOR LEAKS in one or more ways:  
Apply soapy water to connections. Look for  
bubbles. Listen for hiss of escaping gas. Feel for  
extreme cold. Smell for rotten egg odor. Never  
use a flame. Do not use if leaking.  
To Light  
DANGER  
Fig. 8  
To Turn Off  
• EXPLOSION - FIRE HAZARD  
• LPG is heavier than air and can accumulate in  
low places. If you smell gas, leave the  
area immediately.  
Turn FUEL VALVE “off”. (Fig. 9)  
• Always attach or detach LPG source  
outdoors; never while stove is lighted, near  
flame, pilot lights, other ignition sources or  
while stove is hot to touch.  
• This stove is very hot during use and can  
ignite flammables too close to the burners.  
Keep flammables at least 24 inches from the  
sides and 48 inches from the top of the stove.  
Keep gasoline and other flammable liquids  
and vapors well away from stove.  
• The stove must not be exposed to flammable  
vapors or liquids during lighting.  
WARNING  
• BURN HAZARD  
• Never leave stove unattended when hot  
or in use.  
Fig. 9  
• Keep out of reach of children.  
English-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Clean  
To Store  
DANGER  
Make sure stove is cool.  
Move stove away from flame (including pilot  
lights) and other ignition sources.  
Remove LPG cylinder from stove. (Fig. 10)  
• EXPLOSION - FIRE HAZARD  
• Never store LPG near high heat, open flames,  
pilot lights, direct sunlight, other ignition  
sources or where temperatures exceed 120  
degrees F (49°C).  
• The cylinder must be disconnected when the  
stove is in storage.  
Things You Should Know  
1. It is unsafe and illegal in some places to store or  
use LPG cylinders of greater than 1.14 kg (2.5  
lbs) water capacity (approximately 1 lb. LPG) in  
occupied enclosures.  
2. The usual storage areas for camping and picnic  
equipment are the basement, attic, or garage.  
To avoid the accumulation of dust, cobwebs,  
etc., that is common in these areas, place your  
stove in a plastic bag and seal it with a rubber  
band.  
3. If your stove burns with a yellow smokey flame,  
pull to remove the burner, and check the burner  
and air tube for spider webs (Fig. 11).  
Fig. 10  
4. For repair service call one of the numbers listed below  
for location of your nearest Coleman Service Center.  
If stove must be mailed to Service Center, attach to  
the product a tag that includes your name, address,  
daytime telephone number and a description of  
problem. Do NOT send LPG cylinder. Carefully  
package the product and send either by courier or  
insured mail with shipping and insurance prepaid to:  
• MAINTENANCE DURING EACH USE  
• Keep stove area clear and free from  
combustible materials, gasoline and other  
flammable vapors and liquids.  
• Do not obstruct the flow of combustion and  
ventilation air.  
• A good flame should be blue with minimal  
yellow tip. Some yellow tips on flames are  
acceptable as long as no carbon or soot  
deposits appear.  
• Wipe clean with soft cloth and mild dish  
detergent. Do not use abrasives.  
For products purchased in the United States:  
The Coleman Company, Inc.  
3600 North Hydraulic • Wichita, KS 67219  
1-800-835-3278 • TDD: 316-832-8707  
5. If not completely satisfied with the performance  
of this product, please call one of the numbers  
listed above.  
Check for spiderwebs  
Fig. 11  
English-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Limited Five Year Warranty  
The Coleman Company, Inc. (“Coleman”) warrants that for a  
period of five years from the date of original retail purchase,  
this product will be free from defects in material and  
workmanship. Coleman, at its option, will repair or replace this  
product or any component of the product found to be defective  
during the warranty period. Replacement will be made with a  
new or remanufactured product or component. If the product is  
no longer available, replacement may be made with a similar  
product of equal or greater value. This is your exclusive  
warranty.  
This warranty is valid for the original retail purchaser from  
the date of initial retail purchase and is not transferable. Keep  
the original sales receipt. Proof of purchase is required to  
obtain warranty performance. Coleman dealers, service  
centers, or retail stores selling Coleman® products do not have  
the right to alter, modify or in any way change the terms and  
conditions of this warranty.  
What This Warranty Does Not Cover  
This warranty does not cover normal wear of parts, parts that  
are not genuine Coleman® parts, or damage resulting from  
any of the following: negligent use or misuse of the product;  
use on improper voltage or current; commercial use of the  
product; use contrary to the operating instructions;  
disassembly, repair or alteration by anyone other than Coleman  
or an authorized service center. Further, the warranty does not  
cover Acts of God, such as fire, flood, hurricanes and  
tornadoes. Warranty void if damage to product results from the  
use of a part other than a genuine Coleman® part.  
COLEMAN SHALL NOT BE LIABLE FOR DEFECTS THAT  
ARE CAUSED BY THE USE OF UNAUTHORIZED PARTS OR  
SERVICE. COLEMAN SHALL NOT BE LIABLE FOR ANY  
INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY  
THE BREACH OF ANY EXPRESS OR IMPLIED WARRANTY  
OR CONDITIONS. EXCEPT TO THE EXTENT PROHIBITED  
BY APPLICABLE LAW, ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE IS LIMITED IN DURATION TO THE DURATION OF  
THE ABOVE WARRANTY OR CONDITIONS. SOME STATES,  
PROVINCES, OR JURISDICTIONS DO NOT ALLOW THE  
EXCLUSION OR LIMITATION OF INCIDENTAL OR  
CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW  
LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE  
LIMITATIONS OR EXCLUSION MAY NOT APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,  
AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY  
FROM STATE TO STATE OR PROVINCE TO PROVINCE.  
How to Obtain Warranty Service  
Take the product to an authorized Coleman service center.  
You can find the nearest authorized Coleman service center by  
visiting www.coleman.com or calling 1-800-835-3278 or TDD  
316-832-8707 in the United States. If a service center is not  
conveniently located, attach to the product a tag that includes  
your name, address, daytime telephone number and  
description of the problem. Include a copy of the original sales  
receipt. Carefully package the product and send either by  
courier or insured mail with shipping and insurance  
prepaid to:  
For products purchased in the United States:  
The Coleman Company, Inc.  
3600 North Hydraulic  
Wichita, KS 67219  
The costs of transporting the product to Coleman or an  
authorized service center for warranty service is the  
responsibility of the purchaser.  
Do not mail products with fuel in tanks, or with disposable  
LPG cylinders. Remove glass globes from lanterns and wrap  
separately.  
DO NOT RETURN THIS PRODUCT TO THE PLACE OF  
PURCHASE.  
If you have any questions regarding this warranty please call  
1-800-835-3278 or TDD 316-832-8707 in the United States.  
English-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes:  
English-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cobra Electronics Automobile Alarm 8165 User Manual
Craftsman Lawn Mower Accessory 48624839 User Manual
Crown Stereo Amplifier LPS 1500 User Manual
Curtis CRT Television TV2740 Black User Manual
Delfield Refrigerator UC4448N 18M User Manual
Electro Voice Portable Speaker S 122 User Manual
FEIN Power Tools Power Screwdriver SCT 6 25 User Manual
Frigidaire Cooktop FGIC13P3KS User Manual
Garland Cooktop GI SH DU GR 10000 User Manual
Gitzo Camcorder Accessories GT2940LVL User Manual