Cisco Systems IP Phone OL 24582 01 User Manual

A P P E N D I X  
C
Technical Specifications  
The following sections describe the technical specifications for the Cisco Unified IP Phone 6901 and  
6911.  
Physical and Operating Environment Specifications  
Table C-1 shows the physical and operating environment specifications for the Cisco Unified  
IP Phone 6901.  
Table C-1  
Physical and Operating Environment Specifications for the Cisco Unified IP Phone 6901  
Specification  
Value or Range  
Operating temperature 23° to 113°F (-5° to 45°C)  
Operating relative humidity 10% to 90% (non-condensing)  
Storage temperature  
Height  
-13° to 158°F (–25° to 70°C)  
8.1 in. (20.5 cm)  
Width  
3.7 in. (9.4 cm)  
Depth  
2.12 in. (5.4 cm)—With footstand closed  
3.42 in. (8.7 cm)—With footstand open  
Weight  
Power  
1.37 lb (621.2 g)—Black handset phone (Europe)  
1.37 lb (662 g)—White handset phone (Europe)  
1.44 lb (655.2 g)—Black handset phone (North America)  
1.53 lb (695 g)—White handset phone (North America)  
100-240 VAC, 50-60 Hz, 0.5 A—When using the AC adapter  
48 VDC, 0.2 A—When using the in-line power over the network cable  
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)  
OL-24582-01  
C-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix C Technical Specifications  
Network and Access Port Pinouts  
Network and Access Port Pinouts  
Although both the network and access ports are used for network connectivity, they serve different  
purposes and have different port pinouts.  
The network port is labeled network on the Cisco Unified IP Phone.  
The access port is labeled Computer on the Cisco Unified IP Phone (Cisco Unified IP Phone 6911  
only).  
Network Port Connector  
Table C-3 describes the network port connector pinouts.  
Table C-3  
Network Port Connector Pinouts  
Pin Number  
Function  
BI_DA+  
BI_DA-  
BI_DB+  
BI_DC+  
BI_DC-  
BI_DB-  
BI_DD+  
BI_DD-  
1
2
3
4
5
6
7
8
Note  
“BI” stands for bi-directional, while DA, DB, DC and DD stand for “Data A”, “Data  
B”, “Data C” and “Data D”, respectively.  
Access Port Connector  
Table C-4 describes the access port connector pinouts.  
Table C-4  
Access Port Connector Pinouts  
Pin Number  
Function  
BI_DB+  
BI_DB-  
BI_DA+  
BI_DD+  
BI_DD-  
BI_DA-  
BI_DC+  
BI_DC-  
1
2
3
4
5
6
7
8
Note  
“BI” stands for bi-directional, while DA, DB, DC and DD stand for “Data A”, “Data  
B”, “Data C” and “Data D”, respectively.  
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)  
OL-24582-01  
C-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Appendix C Technical Specifications  
Network and Access Port Pinouts  
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)  
OL-24582-01  
C-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bifinett Scale KH 1155 User Manual
Blodgett Convection Oven CTBR Series User Manual
Bodum Grinder 11002 User Manual
Bravetti Toaster TO160H User Manual
Briggs Stratton Telephone Model 040205 0 User Manual
Cadence Speaker XLNS 12 User Manual
Cambridge Audio Car Amplifier 550A User Manual
Canton Speaker CD 3500 User Manual
CDA Cooktop HVN 32 User Manual
Century Welder IM10008 User Manual